Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

MAPPING THE GALACTIC CENTER WITH GRAVITATIONAL WAVE MEASUREMENTS USING PULSAR TIMING

We examine the nHz gravitational wave (GW) foreground of stars and black holes (BHs) orbiting SgrA* in the Galactic center. A cusp of stars and BHs generates a continuous GW spectrum below 40 nHz; individual BHs within 1 mpc to SgrA* stick out in the spectrum at higher GW frequencies. The GWs and gravitational near-field effects can be resolved by timing pulsars within a few pc of this region. Observations with the Square Kilometer Array may be especially sensitive to intermediate-mass BHs in this region, if present. A 100 ns-10 {mu}s timing accuracy is sufficient to detect BHs of mass 1000 M{sub Sun} with pulsars at distance 0.1-1 pc in a 3 yr observation baseline. Unlike electromagnetic imaging techniques, the prospects for resolving individual objects through GW measurements improve closer to SgrA*, even if the number density of objects steeply increases inward. Scattering by the interstellar medium will pose the biggest challenge for such observations.

79 ASTRONOMY AND ASTROPHYSICS↗

The proton form factor measurements at Jefferson Lab, past and future

Use of the double-polarization technique to obtain the elastic nucleon form factors has resulted in a dramatic improvement of the quality of two of the four nucleon electromagnetic form factors, G{sub Ep} and G{sub En}. It has also changed our understanding of the proton structure, having resulted in a distinctly different Q{sup 2}-dependence for both G{sub Ep} and G{sub Mp}, contradicting the prevailing wisdom of the 1990’s based on cross section measurements, namely that G{sub Ep} and G{sub Mp} obey a “scaling” relation μG{sub Ep} ∼ G{sub Mp}. A related consequence of the faster decrease of G{sub Ep} revealed by the Jefferson Lab (JLab) polarization results was the disappearance of the early scaling F{sub 2}/F{sub 1} ∼ 1/Q{sup 2} predicted by perturbative QCD. In three experiments, GEp(1), GEp(2) and GEp(3), in Halls A and C at JLab, the ratio of the proton’s electromagnetic elastic form factors, G{sub Ep}/G{sub Mp}, was measured up to four momentum transfer Q{sup 2} of 8.5 GeV{sup 2} with high precision, using the recoil polarization technique. The initial discovery that the proton form factor ratio measured in these three experiments decreases approximately linearly with four-momentum transfer, Q{sup 2}, for values above ∼ 1 GeV{sup 2}, was modified by the GEp(3) results, which suggests a slowing down of this decrease. There is an approved experiment, GEp(5), to continue these measurements to 15 GeV{sup 2}. A dedicated experimental setup, the super bigbite spectrometer (SBS), will be built for this purpose. It will be equipped with a new focal plane polarimeter to measure the polarization of the recoil protons. In this presentation, I will review the status of the proton elastic electromagnetic form factors, mention succinctly a number of theoretical approaches to describe results and show some features required for the future GEp(5) experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a high current density, high temperature superconducting cable for pulsed magnets

Abstract A low AC loss Rare Earth Barium Copper Oxide (REBCO) cable, based on the VIPER cable technology has been developed by Commonwealth Fusion Systems for use in high field, REBCO based tokamaks. The new cable is composed of partitioned and transposed copper ‘petals’ shaped to fit together in a circular pattern with each petal containing a REBCO tape stack and insulated from each other to reduce AC losses. A stainless steel jacket adds mechanical robustness—also serving as a vessel for solder impregnation—while a tube runs through the middle for cooling purposes. Additionally, fiber optic sensors are placed under the tape stacks for quench detection. To qualify this design, a series of experiments were conducted as part of the SPARC tokamak Central Solenoid Model Coil program—to retire the risks associated with full scale, fast ramping, high flux HTS Central Solenoid (CS) and Poloidal Field (PF) coils for tokamak fusion power plants and net energy demonstrators. These risk study and risk reduction experiments include (1) AC loss measurement and model validation in the range of ~5 T/s, (2) an IxB electromagnetic loading of over 850 kN/m at the cable level and up to 300 kN/m at the stack level, (3) a transverse compression resilience of over 350 MPa, (4) manufacturability at tokamak relevant speeds and scales, (5) cable to cable joint performance, (6) fiber optic based quench detection speed, accuracy, and feasibility, and (7) overall winding pack integration and magnet assembly. The result is a cable technology, now referred to as PIT VIPER, with AC losses that measure fifteen times lower (at ~5 T/s) than its predecessor technology; a 2% or lower degradation of critical current (Ic) at high IxB electromagnetic loads; no detectable Ic degradation up to 570 MPa of transverse compression on the cable unit cell; end to end magnet manufacturing, consistently producing Ic values within 7% of the model prediction; cable to cable joint resistances at 20 K on the order of ~15 nΩ; and fast, functional quench detection capabilities that do not involve voltage taps. This cable technology will be tested comprehensively in a Central Solenoid Model Coil to prove its readiness for compact, high field tokamak operation.

Sanabria, Charlie (ORCID:0000000150175309)↗

Influence of the electron spin resonance saturation on the power sensitivity of cryogenic sapphire resonators

Here, we study the paramagnetic ions behavior in presence of a strong microwave electromagnetic field sustained inside a cryogenic sapphire whispering gallery mode resonator. The high frequency measurement resolution that can be now achieved by comparing two Cryogenic Sapphire Oscillators (CSOs) permit to observe clearly the non-linearity of the resonator power sensitivity. These observations that, in turn, allow us to optimize the CSO operation are well explained by the electron spin resonance saturation of the paramagnetic impurities contained in the sapphire crystal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of Low-Frequency Electromagnetic Radiation from Laser-Plasmas

When an intense short laser pulse interacts with plasmas, the nonlinear interaction causes various phenomena such as high energy particle generation, strong radiation in the x-ray to THz frequency range. Formation of solitons is one of these interesting topics and has been studied mainly from theoretical aspects. Solitons are formed in an underdense plasma in the process of the laser pulse frequency downshift. They store a portion of the EM wave energy with the polarization inherited from the laser pulse-driver and emit it at the plasma-vacuum interface in the form of low frequency EM bursts. Solitons were observed experimentally by proton-beam imaging and in the visible-near-infrared emissions from the plasma. A low frequency EM radiation emission has also been observed in our experiments. The interpretation invokes the relativistic electromagnetic solitons. We present the results of the polarization-resolved measurements of low frequency radiation from the plasma region irradiated by the intense laser pulse. A dominant component of the observed THz radiation has the same polarization as the driver laser pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radar Wind Profiler (RWP) and Radio Acoustic Sounding System (RASS) Instrument Handbook

The radar wind profiler (RWP) is an active remote-sensing instrument that can routinely, and virtually unattended, observe wind and turbulence in the troposphere through scattering from clear-air irregularities of the atmospheric refractive index (Gage and Balsley 1978). The principle of Doppler radars in general is based on sending electromagnetic pulses in the vertical and several tilted directions (vertical and oblique beams) and measuring the signal that is scattered back by atmospheric turbulence at all heights and received at the antenna. The RWPs provides measurements of backscattered signal strength and wind profiles nominally between 0.1 km and 6 km. The RWP operation assumes that the wind field is homogeneous over the spatial separation of the antenna beams, which is a safe assumption under stable atmospheric conditions. However, the wind may be different between the beams due to significant changes in the wind field, resulting in erroneous wind calculations. Therefore, the radial measurements are averaged over a sufficient time period to validate the assumption of homogeneity.

54 ENVIRONMENTAL SCIENCES↗

Influence of solar heating on the performance of integrated solar cell microstrip patch antennas

The integration of microstrip patch antennas with photovoltaics has been proposed for applications in autonomous wireless communication systems located on building facades. Full integration was achieved using polycrystalline silicon solar cells as both antenna ground plane and direct current power generation in the same device. An overview of the proposed photovoltaic antenna designs is provided and the variation characterised of the electromagnetic properties of the device with temperature and solar radiation. Measurements for both copper and solar antennas are reported on three different commercial laminates with contrasting values for thermal coefficient of the dielectric constant. (author)

14 SOLAR ENERGY↗

Engineering aspects of design and integration of ECE diagnostic in ITER

ITER ECE diagnostic [1] needs not only to meet measurement requirements, but also to withstand various loads, such as electromagnetic, mechanical, neutronic and thermal, and to be protected from stray ECH radiation at 170 GHz and other millimeter wave emission, like Collective Thomson scattering which is planned to operate at 60 GHz. Same or similar loads will be applied to other millimetre-wave diagnostics [2], located both in-vessel and in-port plugs. These loads must be taken into account throughout the design phases of the ECE and other microwave diagnostics to ensure their structural integrity and maintainability. The integration of microwave diagnostics with other ITER systems is another challenging activity which is currently ongoing through port integration and in-vessel integration work. Port Integration has to address the maintenance and the safety aspects of diagnostics, too. Engineering solutions which are being developed to support and to operate ITER ECE diagnostic, whilst complying with safety and maintenance requirements, are discussed in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New micro-beam beamline at SPring-8, targeting at protein micro-crystallography

A new protein micro-crystallography beamline BL32XU at SPring-8 is under construction and scheduled to start operation in 2010. The beamline is designed to provide the stabilized and brilliant micro-beam to collect high-quality data from micro-crystals. The beamline consists of a hybrid in-vacuum undulator, a liquid-nitrogen cooled double crystal monochromator, and K-B focusing mirrors with large magnification factor. Development of data acquisition system and end station consists of high-precision diffractometer, high-efficiency area detector, sample auto-changer etc. are also in progress.

43 PARTICLE ACCELERATORS↗

Electric Dipole Moments in Radioactive Nuclei, Tests of Time Reversal Symmetry

The research of radioactive nuclei opens new possibilities to study fundamental symmetries, such as time reversal and reflection symmetry. Such nuclei often provide conditions to check in an optimal way certain symmetries and the violation of such symmetries. We will discuss the possibility of obtaining improved limits on violation of time reversal symmetry using pear shaped radioactive nuclei. An effective method to test time reversal invariance in the non-strange sector is to measure parity and time reversal violating (T-P-odd) electromagnetic moments, (such as the static electric dipole moment). Parity and time reversal violating components in the nuclear force may produce P-T-odd moments in nuclei which in turn induce such moments in atoms. We will discuss the possibility that in some reflection asymmetric, heavy nuclei (which are radioactive) these moments are enhanced by several orders of magnitude. Present and future experiments, which will test this idea, will be mentioned.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Entanglement Created by Dissipation

A technique for entangling closely separated atoms by the process of dissipative spontaneous emission is presented. The system considered is composed of two non-identical two-level atoms separated at the quarter wavelength of a driven standing wave laser field. At this atomic distance, only one of the atoms can be addressed by the laser field. In addition, we arrange the atomic dipole moments to be oriented relative to the inter-atomic axis such that the dipole-dipole interaction between the atoms is zero at this specific distance. It is shown that an entanglement can be created between the atoms on demand by tuning the Rabi frequency of the driving field to the difference between the atomic transition frequencies. The amount of the entanglement created depends on the ratio between the damping rates of the atoms, but is independent of the frequency difference between the atoms. We also find that the transient buildup of an entanglement between the atoms may differ dramatically for different initial atomic conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physics with charmonium - Highlights of BESIII and PANDA

The physics of the strong interaction is undoubtedly one of the most challenging areas of modern science. Quantum ChromoDynamics (QCD) is reproducing successfully the physics phenomena at distances much shorter than the size of the nucleon, where perturbation theory can be used yielding results of high precision and predictive power. At larger distance scales, however, perturbative methods cannot be applied anymore, although spectacular phenomena, such as the generation of hadron masses and quark confinement, occur. Studies using charmed quarks and gluon-rich matter have the potential to connect the perturbative and the non-perturbative QCD region. The annihilation of matter with antimatter in the mass regime of charmonium is an ideal environment to discover new states or transitions that could reveal the secrets of the strong interaction. Hadronic and electromagnetic transitions between charmonium states and their decays have been measured with a world-record in precision with the BESIII spectrometer at the electron-positron collider at IHEP Beijing, China. Moreover, unconventional narrow charmonium-rich states have been discovered recently in an energy regime above the open-charm threshold, thereby, possibly initiating a new era in charmonium spectroscopy. The near future experiment, PANDA, at the research facility FAIR in Germany, Darmstadt, will exploit the annihilation of cooled anti-protons with protons to perform charmonium spectroscopy with an incredible precision. I will present the most promising results that have been recently obtained with BESIII together with the future perspectives of PANDA in the field of charmonium spectroscopy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The hadronic corrections to muonic hydrogen Lamb shift from ChPT and the proton radius

We obtain a model independent expression for the muonic hydrogen Lamb shift. The leading hadronic effects are controlled by the chiral theory, which allows for their model independent determination. We give their complete expression including the pion and Delta particles. Out of this analysis and the experimental measurement of the muonic hydrogen Lamb shift we determine the electromagnetic proton radius: r{sub p} = 0.8412(15) fm. This number is at 6.8σ variance with respect to the CODATA value. The parametric control of the uncertainties allows us to obtain a model independent determination of the error, which is dominated by hadronic effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gamma ray imager on the DIII-D tokamak

A gamma ray camera is built for the DIII-D tokamak [J. Luxon, Nucl. Fusion 42, 614 (2002)] that provides spatial localization and energy resolution of gamma flux by combining a lead pinhole camera with custom-built detectors and optimized viewing geometry. This diagnostic system is installed on the outer midplane of the tokamak such that its 123 collimated sightlines extend across the tokamak radius while also covering most of the vertical extent of the plasma volume. A set of 30 bismuth germanate detectors can be secured in any of the available sightlines, allowing for customizable coverage in experiments with runaway electrons in the energy range of 1–60 MeV. Commissioning of the gamma ray imager includes the quantification of electromagnetic noise sources in the tokamak machine hall and a measurement of the energy spectrum of background gamma radiation. First measurements of gamma rays coming from the plasma provide a suitable testbed for implementing pulse height analysis that provides the energy of detected gamma photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doppler Backscattering Data Analysis and Integrated Modeling with OMFIT

One Modeling Framework for Integrated Tasks (OMFIT) is a widely used software tool in the magnetic fusion research community. OMFIT provides magnetic fusion energy researchers with a framework for the development of special-purpose physics modules. This paper describes an OMFIT physics module pertaining to the Doppler Backscattering (DBS) fusion plasma diagnostic. DBS measures density fluctuations and flow velocity through plasma scattering of electromagnetic waves. The OMFIT DBS module was developed to analyze experimental DBS data and facilitate modeling of DBS systems installed on multiple tokamak devices. The OMFIT DBS module is designed to support several analysis workflows: detailed analysis of experimental data, experimental planning, and theory-based synthetic diagnostic modeling. The DBS module uses integrated modeling by leveraging other OMFIT physics modules to perform tasks related to DBS, e.g. ray/beam–tracing simulations, edge-localized mode–synchronized data analysis, magnetic equilibrium reconstruction, and fitting kinetic profile data. Furthermore, this paper describes several supported workflows and serves a reference for the OMFIT DBS module.

Doppler backscattering↗

SPITZER OBSERVATIONS OF PASSIVE AND STAR-FORMING EARLY-TYPE GALAXIES: AN INFRARED COLOR-COLOR SEQUENCE

We describe the infrared properties of a large sample of early-type galaxies, comparing data from the Spitzer archive with Ks-band emission from the Two Micron All Sky Survey. While most representations of this data result in correlations with large scatter, we find a remarkably tight relation among colors formed by ratios of luminosities in Spitzer-Multiband Imaging Photometer bands (24, 70, and 160 mum) and the Ks band. Remarkably, this correlation among E and S0 galaxies follows that of nearby normal galaxies of all morphological types. In particular, the tight infrared color-color correlation for S0 galaxies alone follows that of the entire Hubble sequence of normal galaxies, roughly in order of galaxy type from ellipticals to spirals to irregulars. The specific star formation rate (SFR) of S0 galaxies estimated from the 24 mum luminosity increases with decreasing K-band luminosity (or stellar mass) from essentially zero, as with most massive ellipticals, to rates typical of irregular galaxies. Moreover, the luminosities of the many infrared-luminous S0 galaxies can significantly exceed those of the most luminous (presumably post-merger) E galaxies. SFRs in the most infrared-luminous S0 galaxies approach 1-10 solar masses per year. Consistently, with this picture we find that while most early-type galaxies populate an infrared red sequence, about 24% of the objects (mostly S0s) are in an infrared blue cloud together with late-type galaxies. For those early-type galaxies also observed at radio frequencies, we find that the far-infrared luminosities correlate with the mass of neutral and molecular hydrogen, but the scatter is large. This scatter suggests that the star formation may be intermittent or that similar S0 galaxies with cold gaseous disks of nearly equal mass can have varying radial column density distributions that alter the local and global SFRs.

79 ASTRONOMY AND ASTROPHYSICS↗

RECENT X-RAY VARIABILITY OF {eta} CARINAE: THE QUICK ROAD TO RECOVERY

We report continued monitoring of the superluminous binary system {eta} Car by the Proportional Counter Array on the Rossi X-ray Timing Observatory (RXTE) through the 2009 X-ray minimum. The RXTE campaign shows that the minimum began on 2009 January 16, consistent with the phasings of the two previous minima, and overall, the temporal behavior of the X-ray emission was similar to that observed by RXTE in the previous two cycles. However, important differences did occur. The 2-10 keV X-ray flux and X-ray hardness decreased in the 2.5 year interval leading up to the 2009 minimum compared to the previous cycle. Most intriguingly, the 2009 X-ray minimum was about 1 month shorter than either of the previous two minima. During the egress from the 2009 minimum the X-ray hardness increased markedly as it had during egress from the previous two minima, although the maximum X-ray hardness achieved was less than the maximum observed after the two previous recoveries. We suggest that the cycle-to-cycle variations, especially the unexpectedly early recovery from the 2009 X-ray minimum, might have been the result of a decline in {eta} Car's wind momentum flux produced by a drop in {eta} Car's mass loss rate or wind terminal velocity (or some combination), though if so the change in wind momentum flux required to match the X-ray variation is surprisingly large.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗