Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Quantitative assessment of the science return from an orbiting, imaging, optical interferometer

Imaging simulations were performed with the filled Mills cross orbiting, imaging, optical interferometer proposed by Synnott et al. (1990) in order to determine its capabilities in the area of spatial resolution, dynamic range, and sensitivity. Astronomical objects have been chosen as candidate program sources to determine whether this interferometer design can accomplish research goals relating to the objects.

Meier, David L.↗

Compact Raman Spectrometers Would Detect Hydrogen

Compact Raman spectrometers developed to measure concentrations of hydrogen as low as hundreds of parts per million in air, nitrogen, or other carrier gases. Advantages include speed, dynamic range, and ease of calibration. Design concept incorporates Raman-scattering apparatus into compact instrument of hydrogen leaking into stream of gas or into gas enclosed in small space. Should hydrogen-fueled cars and trucks come into widespread use, instruments used to detect leaks from vehicles and supply equipment, to help prevent explosions. Similar spectrometers developed to detect other gases emitting characteristic Raman spectra.

Helms, William R.↗

Testing For Parasitic Lasing With Controlled Retroreflection

Controlled-retroreflection technique provides new capability to test safely for parasitic oscillations in laser. Continuously variable reflector adjusted continuously over dynamic range of about 3 decades by rotation of quarter-wave plate about optical axis. Neutral-density filter establishes maximum reflectivity. By selection of neutral-density filters and continuous adjustment, reflector made to have any reflectivity from about 1 down to 10 to the negative 8th power.

Storm, Mark E.↗

Chemical Dosimeter Tube With Coaxial Sensing Rod

Improved length-of-stain (LOS) chemical dosimeter indicates total dose of chemical vapor in air. Made with rods and tubes of various diameters to obtain various sensitivities and dynamic ranges. Sensitivity larger and dose range smaller when more room for diffusion in gap between tube and rod. Offers greater resistance to changing of color of exposed dye back to color of unexposed condition, greater sensitivity, and higher degree of repeatability. Developed to measure doses of gaseous HCI, dosimeter modified by use of other dyes to indicate doses of other chemical vapors.

Lueck, Dale E.↗

Active Thermal Isolation For Hot-Film Anemometers

Local heating compensates for conduction of heat from sensors into modules. Two hot-film sensors stacked on wind-tunnel model. Outer sensor detects changes in boundary-layer flow. Inner sensor provides active thermal isolation between outer sensor and model. Thermal boundary condition controlled at response time of detection hot-film sensor, significantly less than response time of internally heated model. Requires less power to maintain outer hot-film sensor at given temperature, enabling system to respond over greater dynamic range before power limits of instrument reached. Stacked sensors bonded to surface of most wind-tunnel models, even to curved surfaces, and removed after completion of experiments.

Martinson, Scott D.↗

Microstrip-Transmission-Line Shock-Front Sensor

Microstrip-transmission-line sensor measures velocities of low-overpressure shock fronts and offers dynamic range needed for measurements both far from and near explosions. Fabricated easily, relatively inexpensive, and repaired in field. In addition, basic geometry modified easily, as needed.

Leiweke, Robert J.↗

Programmable Analog-To-Digital Converter

High-speed analog-to-digital converter with programmable voltage steps that can be changed during operation. Allows concentration of converter resolution over specific portion of waveform. Particularly useful in digitizing wind-shear radar and lidar return signals, in digital oscilloscopes, and other applications in which desirable to increase digital resolution over specific area of waveform while accepting lower resolution over rest of waveform. Effective increase in dynamic range achieved without increase in number of analog-to-digital converter bits. Enabling faster analog-to-digital conversion.

Kist, Edward H., Jr.↗

The trade-off characteristics of acoustic and pressure sensors for the NASP

Results of a trade study for the development of pressure and acoustic sensors for use on the National Aerospace Plane (NASP) are summarized. Pressure sensors are needed to operate to 100 psia; acoustic sensors are needed that can give meaningful information about a 200 dB sound pressure level (SPL) environment. Both sensors will have to operate from a high temperature of 2000 F down to absolute zero. The main conclusions of the study are the following: (1) Diaphragm materials limit minimum size and maximum frequency response attainable. (2) No transduction is available to meet all the NASP requirements with existing technology. (3) Capacitive sensors are large relative to the requirement, have limited resolution and frequency response due to noise, and cable length is limited to approximately 20 feet. (4) Eddy current sensors are large relative to the requirement and have limited cable lengths. (5) Fiber optic sensors provide the possibility for a small sensor, even though present developments do not exhibit that characteristic. The need to use sapphire at high temperature complicates the design. Present high temperature research sensors suffer from poor resolution. A significant development effort will be required to realize the potential of fiber optics. (6) Short-term development seems to favor eddy current techniques with the penalty of larger size and reduced dynamic range for acoustic sensors. (7) Long-term development may favor fiber optics with the penalties of cost, schedule, and uncertainty.

Winkler, Martin↗

Fiber-optic three axis magnetometer prototype development

The goal of this research program was to develop a high sensitivity, fiber optic, interferometric, three-axis magnetometer for interplanetary spacecraft applications. Dynamics Technology, Inc. (DTI) has successfully integrated a low noise, high bandwidth interferometer with high sensitivity metallic glass transducers. Also, DTI has developed sophisticated signal processing electronics and complete data acquisition, filtering, and display software. The sensor was packaged in a compact, low power and weight unit which facilitates deployment. The magnetic field sensor had subgamma sensitivity and a dynamic range of 10(exp 5) gamma in a 10 Hz bandwidth. Furthermore, the vector instrument exhibited the lowest noise level when only one axis was in operation. A system noise level of 1 gamma rms was observed in a 1 Hz bandwidth. However, with the other two channels operating, the noise level increased by about one order of magnitude. Higher system noise was attributed to cross-channel interference among the dither fields.

Wang, Thomas D.↗

Development of microchannel plates in advanced wind-tunnel instrumentation

Microchannel plate (MCP) electron multiplier dynamic range has been increased 3 to 4 orders of magnitude at ambient temperatures, through enhanced input count rate capability and reduced background or 'dark' noise. The previous upper limit of roughly 10(exp 7) - 10(exp 8) cm(exp -2)s(exp -1) at ambient has been extended to levels approach 10(exp 10) cm(exp -2)s(exp -1) under continuous dc operation. The lower limit, previously set by an irreducible background component (approximately 0.6 cm(exp -2)s(exp -1)), has been lowered to the cosmic ray limit of .01 cm(exp -2)s(exp -1). The high end improvement was achieved by conductively cooling a very low resistance MCP by bonding it to a heat sink, while maintaining pulse-counting operation with multianode readouts. The low-end improvement was achieved by removing all radioisotopes from the MCP matrix glass. The detectors will benefit optical and mass spectrometry, flow visualization, plasma diagnostics, magnetometry, and other high signal flux applications. Very low MCP background noise will benefit X-ray and UV astronomy, medical imaging, trace isotope mass spectrometry, and other applications where the signal flux is often extremely low.

Feller, W. Bruce↗

Reliable and Efficient Parallel Processing Algorithms and Architectures for Modern Signal Processing

Least-squares (LS) estimations and spectral decomposition algorithms constitute the heart of modern signal processing and communication problems. Implementations of recursive LS and spectral decomposition algorithms onto parallel processing architectures such as systolic arrays with efficient fault-tolerant schemes are the major concerns of this dissertation. There are four major results in this dissertation. First, we propose the systolic block Householder transformation with application to the recursive least-squares minimization. It is successfully implemented on a systolic array with a two-level pipelined implementation at the vector level as well as at the word level. Second, a real-time algorithm-based concurrent error detection scheme based on the residual method is proposed for the QRD RLS systolic array. The fault diagnosis, order degraded reconfiguration, and performance analysis are also considered. Third, the dynamic range, stability, error detection capability under finite-precision implementation, order degraded performance, and residual estimation under faulty situations for the QRD RLS systolic array are studied in details. Finally, we propose the use of multi-phase systolic algorithms for spectral decomposition based on the QR algorithm. Two systolic architectures, one based on triangular array and another based on rectangular array, are presented for the multiphase operations with fault-tolerant considerations. Eigenvectors and singular vectors can be easily obtained by using the multi-pase operations. Performance issues are also considered.

Liu, Kuojuey Ray↗

PARAS program: Phased array radio astronomy from space

An orbiting radio telescope is proposed which, when operated in a Very Long Baseline Interferometry (VLBLI) scheme, would allow higher (than currently available) angular resolution and dynamic range in the maps, and the ability of observing rapidly changing astronomical sources. Using a passive phases array technology, the proposed design consists of 656 hexagonal modules forming a 150 meter diameter dish. Each observatory module is largely autonomous, having its own photovoltaic power supply and low-noise receiver and processor for phase shifting. The signals received by the modules are channeled via fiber optics to the central control computer in the central bus module. After processing and multiplexing, the data is transmitted to telemetry stations on the ground. The truss frame supporting each observatory pane is a hybrid structure consisting of a bottom graphite/epoxy tubular triangle and rigidized inflatable Kevlar tubes connecting the top observatory panel and bottom triangle. Attitude control and stationkeeping functions are performed by a system of momentum wheels in the bus and four propulsion modules located at the compass points on the periphery of the observatory dish. Each propulsion module has four monopropellant thrusters and six hydrazine arcjets, the latter supported by a nuclear reactor. The total mass of the spacecraft is 22,060 kg.

Jakubowski, Antoni K.↗

Ultra-stable, low phase noise dielectric resonator stabilized oscillators for military and commercial systems

EPSD has designed, fabricated and tested, ultra-stable, low phase noise microwave dielectric resonator oscillators (DRO's) at S, X, Ku, and K-bands, for potential application to high dynamic range and low radar cross section target detection radar systems. The phase noise and the temperature stability surpass commercially available DROs. Low phase noise signals are critical for CW Doppler radars, at both very close-in and large offset frequencies from the carrier. The oscillators were built without any temperature compensation techniques and exhibited a temperature stability of 25 parts per million (ppm) over an extended temperature range. The oscillators are lightweight, small and low cost compared to BAW & SAW oscillators, and can impact commercial systems such as telecommunications, built-in-test equipment, cellular phone and satellite communications systems. The key to obtaining this performance was a high Q factor resonant structure (RS) and careful circuit design techniques. The high Q RS consists of a dielectric resonator (DR) supported by a low loss spacer inside a metal cavity. The S and the X-band resonant structures demonstrated loaded Q values of 20,300 and 12,700, respectively.

Mizan, Muhammad↗

Automated in situ observations of upper ocean biogeochemistry, bio-optics, and physics and their potential use for global studies

The processes controlling the flux of carbon in the upper ocean have dynamic ranges in space and time of at least nine orders of magnitude. These processes depend on a broad suite of inter-related biogeochemical, bio-optical, and physical variables. These variables should be sampled on scales matching the relevant phenomena. Traditional ship-based sampling, while critical for detailed and more comprehensive observations, can span only limited portions of these ranges because of logistical and financial constraints. Further, remote observations from satellite platforms enable broad horizontal coverage which is restricted to the upper few meters of the ocean. For these main reasons, automated subsurface measurement systems are important for the fulfillment of research goals related to the regional and global estimation and modeling of time varying biogeochemical fluxes. Within the past few years, new sensors and systems capable of autonomously measuring several of the critical variables have been developed. The platforms for deploying these systems now include moorings and drifters and it is likely that autonomous underwater vehicles (AUV's) will become available for use in the future. Each of these platforms satisfies particular sampling needs and can be used to complement both shipboard and satellite observations. In the present review, (1) sampling considerations will be summarized, (2) examples of data obtained from some of the existing automated in situ sampling systems will be highlighted, (3) future sensors and systems will be discussed, (4) data management issues for present and future automated systems will be considered, and (5) the status of near real-time data telemetry will be outlined. Finally, we wish to make it clear at the outset that the perspectives presented here are those of the authors and are not intended to represent those of the United States JGOFS program, the International JGOFS program, NOAA's C&GC program, or other global ocean programs.

Dickey, Tommy D.↗

The spatial correlation properties of dark galaxy halos in a CDM universe

We use the Hierarchical Particle Mesh (HPM) N-body code written by J. V. Villumsen (Villumsen, 1989) to investigate the two-point spatial correlation function, xi(r), of dark galaxy halos as a function of halo mass and local environment (i.e. high, low, or average mass density). We assume a standard cold dark matter (CDM) universe (omega = 1, delta = 0, H sub 0 = 50,km/sec/Mpc). Because of the large dynamic ranges in mass and length that can be obtained with the HPM code, it is well-suited to an investigation of this sort.

Brainerd, Tereasa G.↗

New technologies for UV detectors

Several technologies are currently being developed, leading to substantial improvements in the performance of UV detectors or significant reductions in power or weight. Four technologies discussed are (1) thin-film coatings to enhance the UV sensitivity of CCD's, (2) highly innovative magnet assemblies that dramatically reduce weight and result in virtually no external flux, (3) new techniques for curving microchannel plates (MCP's) so that single plates can be used to prevent ion feedback and present highly localized charge clouds to an anode structure, and (4) high-performance alternatives to glass-based MCP's. In item (2), for example, very robust magnets are made out of rare earth materials such as samarium cobalt, and cladding magnets are employed to prevent flux from escaping from the detector into the external environment. These new ultralight magnet assemblies are able to create strong, exceptionally uniform magnetic fields for image intensification and focusing of photoelectrons. The principle advantage of such detectors is the quantum efficiencies of 70-80 percent obtained throughout ultraviolet wavelengths (900-2000 A), the highest of any device. Despite the improvements achieved under item (3), high-performance alternatives to conventional glass-based MCP's potentially offer three distinct new advantages that include (1) a 30-100-fold improvement in dynamic range resulting in correspondingly higher signal-to-noise ratios, (2) the use of pure dielectric and semiconductor materials that will not outgas contaminants that eventually destroy photocathodes, and (3) channels that have constant spacing providing long-ranged order since the plates are made using photolithography techniques from the semiconductor industry. The manufacturers of these advanced-technology MCP's, however, are a couple of years away from actually producing a functioning image intensifier. In contrast to the use of CCD's for optical, ground based observations, there is no single detector technology in the ultraviolet that dominates or is as universally suitable for all applications. Thus, several technological problems, recent advances, and the impact that these new enabling technologies represent for UV applications are addressed.

Joseph, C. L.↗

Prospects for imaging and astrometry on the ground and implications for space interferometry

The potential imaging performance of large telescopes using adaptive optics with laser guide stars, and of interferometers using laser phased subapertures are considered. The potential astrometric performance from the ground is also discussed. For each case the implications for a space interferometry mission are considered. The advantages of the space environment for optical and infrared astronomical interferometry are: transparency at all wavelength bands, no atmospheric turbulence, and the ability to cool optics for observation in the thermal infrared. However, ground based interferometry also has important advantages: the availability of large apertures and long baselines and generally lower costs. While transparency and thermal emission are fundamental, adaptive optics aided by laser guide stars shows promise to eliminate some of the effects of turbulence for ground based imaging. Other techniques such as phase referencing and closure phase can also be used to circumvent some of the effects of atmospheric turbulence. While it is a long step from the theoretical performance predictions for a ground based instrument to their attainment, a future space imaging interferometer must emphasize those capabilities which are impossible or at least very difficult from the ground: UV observations, very high dynamic range measurements, or high resolution measurements of faint, extended objects. The case for space astrometry is more clear: while ground interferometry can offer high accuracies over very small fields, a space interferometer can offer more than two orders of magnitude better performance over wide fields than that achievable with groundbased systems.

Colavita, M. Mark↗

Characteristics of a dynamic holographic sensor for shape control of a large reflector

Design of a distributed holographic interferometric sensor for measuring the surface displacement of a large segmented reflector is proposed. The reflector's surface is illuminated by laser light of two wavelengths and volume holographic gratings are formed in photorefractive crystals of the wavefront returned from the surface. The sensor is based on holographic contouring with a multiple frequency source. It is shown that the most stringent requirement of temporal stability affects both the temporal resolution and the dynamic range. Principal factor which limit the sensor performance include the response time of photorefractive crystal, laser power required to write a hologram, and the size of photorefractive crystal.

Welch, Sharon S.↗