Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct Air Capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Exploring the limits of crop productivity: beyond the limits of tipburn in lettuce

The productivity of lettuce in a combination of high light, high temperature, and elevated CO2 has not been commonly studied because rapid growth usually causes a calcium deficiency in meristems called tipburn, which greatly reduces quality and marketability. We eliminated tipburn by blowing air directly onto the meristem, which allowed us to increase the photosynthetic photon flux (PPF) to 1000 micromoles m-2 s-1 (57.6 mol m-2 d-1); two to three times higher than normally used for lettuce. Eliminating tipburn doubled edible yield at the highest PPF level. In addition to high PPF, CO2 was elevated to 1200 micromoles m-2 mol-1, which increased the temperature optimum from 25 to 30 degrees C. The higher temperature increased leaf expansion rate, which improved radiation capture and more than doubled yield. Photosynthetic efficiency, measured as canopy quantum yield in a whole-plant gas exchange system, steadily increased up to the highest temperature of 32 degrees C in high CO2. The highest productivity was 19 g m-2 d-1 of dry biomass (380 g d-1 fresh mass) averaged over the 23 days the plants received light. Without the limitation of tipburn, the combination of high PPF, high temperature, and elevated CO2 resulted in a 4-fold increase in growth rate over productivity in conventional environments.

NASA Discipline Life Support Systems↗

20 years of cosmic muons research performed in IFIN-HH

During the last two decades a modern direction in particle physics research has been developed in IFIN-HH Bucharest, Romania. The history started with the WILLI detector built in IFIN-HH Bucharest in collaboration with KIT Karlsruhe (formerly Forschungszentrum Karlsruhe). The detector was designed for measurements of the low energy muon charge ratio (< 1GeV) based on a delayed coincidence method, measuring the decay time of the muons stopped in the detector: the positive muons decay freely, but the negative muons are captured in the atom thus creating muonic atoms and decay depending on the nature of the host atom. In a first configuration, the WILLI detector was placed in a fixed position for measuring vertical muons. Further WILLI has been transformed in a rotatable device which allows directional measurements of muon charge ratio and muon flux. The results exhibit a pronounced azimuthal asymmetry (East-West effect) due to the different in fluence of the geomagnetic field on the trajectories of positive and negative muons in air. In parallel, flux measurement, taking into account muon events with nergies > 0.4GeV, show a diurnal modulation of the muon flux. The analysis of the muon events for energies < 0.6GeV reveals an aperiodic variation of the muon flux. A new detection system performing coincidence measurements between the WILLI calorimeter and a small array of 12 scintillators plates has been installed in IFIN-HH starting from the autumn of 2010. The aim of the system is to investigate muon charge ratio from individual EAS by using the mini-array as trigger for the WILLI calorimeter. Such experimental studies could provide detailed information on hadronic interaction models and primary cosmic ray composition at energies around 10{sup 15}eV. Simulation studies and preliminary experimental tests, regarding the performances of the mini-array, have been performed using H and Fe primaries, with energies in a range 10{sup 13}eV - 10{sup 15}eV. The results show detailed effects of the direction of EAS incidence relative to the geomagnetic field, depending, in particular, of the primary mass. Based on the results, we can say that WILLI-EAS experiment could be used for testing the hadronic interaction models. Measurements of the high energy muon flux in underground of the salt mine from Slanic Prahova, Romania was performed using a new mobile detector developed in IFIN-HH, Bucharest. Consisting of 2 scintillator plates measuring in coincidence, the detector is installed on a van which facilitates measurements on different positions at surface or in underground. The detector was used to measure muon fluxes in different locations at surface or in underground. The detector was used to measure muon fluxes at different sites of Romania and in the underground of the salt mines from Slanic Prahova, Romania where IFIN-HH has a modern underground laboratory. New methods for the detection of cosmic ray muons are investigated in our institute based on scintillator techniques using optical fiber and MPPC photodyodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmarking the Suitability of Novec$^{\mathrm{TM}}$ 4710 for Application in Flux Compression Generators

Here, an experimental study evaluated the feasibility of replacing traditional insulating gases such as SF 6 with C 4 F 7 N (3M TM , Novec 4710) in flux compression generator (FCG) applications. Currently available data indicate that Novec 4710 could offer certain performance benefits over SF 6 . However, the available literature is focused on low frequency (50–60 Hz) and dc at static pressures. To evaluate the performance of Novec 4710 under the pulsed dynamic pressure and temperature conditions found in an FCG, we report a performance comparison between three sets of identical FCGs using air, SF 6 , and Novec 4710 as the insulating gas. The generators used in this study had a single stage, directly seeded design with an armature diameter of 25 mm and a stator diameter of 46 mm. To highlight the performance of the different gases rather than any wire insulation, the stator was constructed with uninsulated wire. Furthermore, the generators were seeded aggressively, making the performance difference between the different gases more apparent. The performance was monitored with a pair of differential Rogowski coils that captured the generators’ di / dt while also using high-speed videography to capture possible gaseous breakdown signatures. The data gathered during this study indicate that Novec 4710 performs at least as well as SF 6 in FCG applications, if not significantly better.

42 ENGINEERING↗

Hi-Q Rotor - Low Wind Speed Technology

The project objective was to optimize the performance of the Hi-Q Rotor. Early research funded by the California Energy Commission indicated the design might be advantageous over state-of-the-art turbines for collecting wind energy in low wind conditions. The Hi-Q Rotor is a new kind of rotor targeted for harvesting wind in Class 2, 3, and 4 sites, and has application in areas that are closer to cities, or 'load centers.' An advantage of the Hi-Q Rotor is that the rotor has non-conventional blade tips, producing less turbulence, and is quieter than standard wind turbine blades which is critical to the low-wind populated urban sites. Unlike state-of-the-art propeller type blades, the Hi-Q Rotor has six blades connected by end caps. In this phase of the research funded by DOE's Inventions and Innovation Program, the goal was to improve the current design by building a series of theoretical and numeric models, and composite prototypes to determine a best of class device. Development of the rotor was performed by aeronautical engineering and design firm, DARcorporation. From this investigation, an optimized design was determined and an 8-foot diameter, full-scale rotor was built and mounted using a Bergey LX-1 generator and furling system which were adapted to support the rotor. The Hi-Q Rotor was then tested side-by-side against the state-of-the-art Bergey XL-1 at the Alternative Energy Institute's Wind Test Center at West Texas State University for six weeks, and real time measurements of power generated were collected and compared. Early wind tunnel testing showed that the cut-in-speed of the Hi-Q rotor is much lower than a conventional tested HAWT enabling the Hi-Q Wind Turbine to begin collecting energy before a conventional HAWT has started spinning. Also, torque at low wind speeds for the Hi-Q Wind Turbine is higher than the tested conventional HAWT and enabled the wind turbine to generate power at lower wind speeds. Based on the data collected, the results of our first full-scale prototype wind turbine proved that higher energy can be captured at lower wind speeds with the new Hi-Q Rotor. The Hi-Q Rotor is almost 15% more productive than the Bergey from 6 m/s to 8 m/s, making it ideal in Class 3, 4, and 5 wind sites and has application in the critical and heretofore untapped areas that are closer to cities, 'load centers,' and may even be used directly in urban areas. The additional advantage of the Hi-Q Rotor's non-conventional blade tips, which eliminates most air turbulence, is noise reduction which makes it doubly ideal for populated urban areas. Hi-Q Products recommends one final stage of development to take the Hi-Q Rotor through Technology Readiness Levels 8-9. During this stage of development, the rotor will be redesigned to further increase efficiency, match the rotor to a more suitable generator, and lower the cost of manufacturing by redesigning the structure to allow for production in larger quantities at lower cost. Before taking the rotor to market and commercialization, it is necessary to further optimize the performance by finding a better generator and autofurling system, ones more suitable for lower wind speeds and rpms should be used in all future testing. The potential impact of this fully developed technology will be the expansion and proliferation of energy renewal into the heretofore untapped Class 2, 3, 4, and 5 Wind Sites, or the large underutilized sites where the wind speed is broken by physical features such as mountains, buildings, and trees. Market estimates by 2011, if low wind speed technology can be developed are well above: 13 million homes, 675,000 commercial buildings, 250,000 public facilities. Estimated commercial exploitation of the Hi-Q Rotor show potential increase in U.S. energy gained through the clean, renewable wind energy found in low and very low wind speed sites. This new energy source would greatly impact greenhouse emissions as well as the public sector's growing energy demands.

17 WIND ENERGY↗

Direct-View Multi-Point Two-Component Interferometric Rayleigh Scattering Velocimeter

This paper describes an instantaneous velocity measurement system based on the Doppler shift of elastically scattered laser light from gas molecules (Rayleigh scattering) relative to an incident laser. The system uses a pulsed laser as the light source, direct-viewing optics to collect the scattered light, an interferometer to analyze spectrally the scattered light mixed with the incident laser light, and a CCD camera to capture the resulting interferogram. The system is capable of simultaneous, spatially (approximately 0.2 mm(exp 3)) and temporally (approximately 40 ns) resolved, multiple point measurements of two orthogonal components of flow velocity in the presence of background scattered light, acoustic noise and vibrations, and flow particulates. Measurements in a large-scale axi-symmetric Mach 1.6 H2-air combustion-heated jet running at a flow sensible enthalpy specific to Mach 5.5 hypersonic flight are performed to demonstrate the technique. The measurements are compared with CFD calculations using a finite-volume discretization of the Favre-averaged Navier-Stokes equations (VULCAN code).

Bivolaru, Daniel↗

Performance Baseline for Oxy-Coal MHD Power Plant with Carbon Capture

This presentation discusses the development of baseline Direct Power Extraction (DPE) plant designs incorporating oxy-coal combustion, a magnetohydrodynamic (MHD) topping cycle, a steam bottoming cycle, and a carbon dioxide purification unit for carbon capture and storage (CCS). Two MHD configurations have been developed; one representing the current state-of-the-art in MHD channel design, and a more advanced design capable of higher power density. The MHD cycle incorporates potassium seeding for plasma generation and a potassium formate seed recovery process that also removes sulfur from the combustion products. The air separation unit for oxygen production, MHD system, and seed recovery systems are all thermally integrated with a Rankine bottoming cycle operating at advanced ultra-supercritical (AUSC) steam conditions. The modeled performance of the two DPE plant systems are compared to IGCC and oxy-coal AUSC reference plants with CCS.

Weiland, Nathan↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗

Impact of nitrate-enhanced leachate recirculation on gaseous releases from a landfill bioreactor cell

This study evaluates the impact of nitrate injection on a full scale landfill bioreactor through the monitoring of gaseous releases and particularly N{sub 2}O emissions. During several weeks, we monitored gas concentrations in the landfill gas collection system as well as surface gas releases with a series of seven static chambers. These devices were directly connected to a gas chromatograph coupled to a flame ionisation detector and an electron capture detector (GC-FID/ECD) placed directly on the field. Measurements were performed before, during and after recirculation of raw leachate and nitrate-enhanced leachate. Raw leachate recirculation did not have a significant effect on the biogas concentrations (CO{sub 2}, CH{sub 4} and N{sub 2}O) in the gas extraction network. However, nitrate-enhanced leachate recirculation induced a marked increase of the N{sub 2}O concentrations in the gas collected from the recirculation trench (100-fold increase from 0.2 ppm to 23 ppm). In the common gas collection system however, this N{sub 2}O increase was no more detectable because of dilution by gas coming from other cells or ambient air intrusion. Surface releases through the temporary cover were characterized by a large spatial and temporal variability. One automated chamber gave limited standard errors over each experimental period for N{sub 2}O releases: 8.1 {+-} 0.16 mg m{sup -2} d{sup -1} (n = 384), 4.2 {+-} 0.14 mg m{sup -2} d{sup -1} (n = 132) and 1.9 {+-} 0.10 mg m{sup -2} d{sup -1} (n = 49), during, after raw leachate and nitrate-enhanced leachate recirculation, respectively. No clear correlation between N{sub 2}O gaseous surface releases and recirculation events were evidenced. Estimated N{sub 2}O fluxes remained in the lower range of what is reported in the literature for landfill covers, even after nitrate injection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A reactive separation process for pre-combustion CO 2 capture employing oxygen-blown coal gasifier off-gas

In this paper, we present an experimental study of a reactive separation system, consisting of a membrane reactor (MR) and an adsorptive reactor (AR) operating in tandem, with the MR’s reject stream serving as the AR’s feed. We investigates the feasibility of applying this MR-AR system for high-purity H 2 production and simultaneous CO 2 capture via the water gas shift (WGS) reaction in the context of Integrated Gas Combined Cycle (IGCC) power generation employing oxygen-blown gasifier syngas from biomass and coal. We previously studied this MR-AR system for the IGCC process employing air-blown gasifier syngas, for which it demonstrated good performance, attaining high conversion exceeding equilibrium, producing ultra-pure H 2 for power generation, and a CO 2 stream ready for sequestration. In this study, we focus on oxygen-blown gasifier off-gas that contains no N 2 , with composition distinctly different from the air-blown gasifier syngas which has a large N 2 content. We employ a carbon molecular sieve membrane (CMSM), a commercial sour-shift WGS catalyst, and a hydrotalcite (HTC) adsorbent. We carried out experiments to determine membrane performance and to identify promising operating conditions in an IGCC-relevant environment. The CMSM proved robust during a long-term (~344 hr run) experimental run under high temperature and pressure maintaining a high He/N 2 selectivity (~170). Multi-cycle runs were carried out during which the MR-AR system displayed superior performance to that of a PBR, by producing a high purity H 2 product directly usable in power generation. Therefore, the findings from this study demonstrate the ability of the MR-AR system to operate stably for a broad range of gasifier off-gas compositions, and indicate its potential for integration into IGCC plants for power generation with CO 2 capture.

01 COAL, LIGNITE, AND PEAT↗

DNS of strong shock and turbulence interaction including real gas effects

The underlying physics in strong shock and turbulence interaction is essential for better understanding of many applications in astrophysics as well as explosive processes. These strongly nonlinear phenomena, however, have proven to be very complex to understand with existing tools. Furthermore, real gas effects including internal energy excitations, translation-vibration energy relaxation, and chemical reactions among different species need to be considered in direct numerical simulation (DNS) of strong shocks, because gas temperature increases dramatically behind the shocks. To solve such problems, a unique approach of using a shock-fitting and shockcapturing method is adopted. The main shock is treated by a shock-fitting method as a sharp boundary of the computational domain. The rest of weak or secondary shocks induced by interactions of the main shock and freestream turbulence are captured by shock-capturing schemes. In this paper, a high-order nonequilibrium flow solver based on 5-species air chemistry and recently thermal property models are implemented and tested. The test of 11-species air chemistry is ongoing, where the ionization of gas particles is considered. The solver is being applied to simulate strong shock and turbulence interaction problems with the main shock Mach number around 20. The paper mainly focuses on the numerical method and results of a test case.

Wang, Xiaowen↗

An evaluation of adhesive sample holders for advanced crystallographic experiments

Commercially available adhesives have been evaluated for crystal mounting when undertaking complex macromolecular crystallography experiments. Here, their use as tools for advanced sample mounting and cryoprotection is assessed and their suitability for room-temperature data-collection and humidity-controlled studies is investigated. The hydration state of macromolecular crystals often affects their overall order and, ultimately, the quality of the X-ray diffraction pattern that they produce. Post-crystallization techniques that alter the solvent content of a crystal may induce rearrangement within the three-dimensional array making up the crystal, possibly resulting in more ordered packing. The hydration state of a crystal can be manipulated by exposing it to a stream of air at controlled relative humidity in which the crystal can equilibrate. This approach provides a way of exploring crystal hydration space to assess the diffraction capabilities of existing crystals. A key requirement of these experiments is to expose the crystal directly to the dehydrating environment by having the minimum amount of residual mother liquor around it. This is usually achieved by placing the crystal on a flat porous support (Kapton mesh) and removing excess liquid by wicking. Here, an alternative approach is considered whereby crystals are harvested using adhesives that capture naked crystals directly from their crystallization drop, reducing the process to a one-step procedure. The impact of using adhesives to ease the harvesting of different types of crystals is presented together with their contribution to background scattering and their usefulness in dehydration experiments. It is concluded that adhesive supports represent a valuable tool for mounting macromolecular crystals to be used in humidity-controlled experiments and to improve signal-to-noise ratios in diffraction experiments, and how they can protect crystals from modifications in the sample environment is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Large-eddy simulations of Richtmyer Meshkov instability in a converging geometry

The Richtmyer-Meshkov instability (RMI) refers to the baroclinic generation of vorticity at a perturbed density interface when impacted by a shock wave. It is often thought of as the impulsive limit of the Rayleigh-Taylor instability. While the RMI has been widely covered in planar geometries, the present simulations investigate the mixing of materials resulting from the interaction of an imploding cylindrical shock wave with a concentric interface, perturbed in both axial and azimuthal directions, which separates outside air from SF{sub 6} (initially 5 times denser) confined in a 90{sup o} wedge. Two incident shocks of Mach numbers M{sub i} = 1.3 and 2.0 at initial impact are tested. These canonical simulations support recent work on understanding the compressible turbulent mixing in converging geometries relevant to both inertial confinement fusion and core-collapse supernova dynamics. Initial irregularities in the density interface form the misalignment between density and pressure gradients required to initiate a first RMI. A second RMI occurs after the initial shock has converged down the wedge, reflected off the axis and reshocks the distorted interface. Reshock interactions of decreasing intensity follow successively. Due to the converging geometry, the accelerated or decelerated motion of the interface also generates Rayleigh-Taylor instabilities. Secondary Kelvin-Helmholtz instabilities develop along the sides of the interpenetrating fingering structures. The energetic reshock produces a large dynamical range of turbulent scales, requiring the utilization of large-eddy simulation (LES). We employed the stretched-vortex subgrid-scale model of turbulent and scalar transport based on an explicit structural modeling of small-scale dynamics. The imploding nature of the flow is particularly suitable for the use of adaptive mesh refinement (AMR) provided by the parallel block-structured AMR framework AMROC. The Favre-filtered Navier-Stokes equations are solved on each Cartesian uniform subgrid of the mesh hierarchy. A weighted, essentially nonoscillatory scheme is used to capture discontinuities but reverts to a low-numerical dissipation, explicit, tuned center-difference stencil in the smooth or turbulent flow regions, optimal for the functioning of our explicit LES. The computational domain is discretized with 95 x 95 x 64 cubic cells on the base grid (64 points in the periodic axial direction), with three additional levels of refinement based on the local density gradient, reducing the computational expenses compared to the equivalent finest unigrid 760 x 760 x 512 problem. The interpenetration of the two fluids after the reshock is clearly discernible in Fig. 1. The mixing is visualized by using isosurfaces of the heavy-fluid mass fraction {psi}. The mixture is colored red as {psi} = 0.90, yellow as {psi} = 0.5, and green as {psi} = 0.1. To illustrate the multiscale nature of the turbulent mixing, we observe that the initial perturbation wavelength is 100 times larger than the finest grid size, which is itself about 100 times larger than the estimated smallest physical scale in the flow - the Kolmogorov scale - where the viscous dissipation of energy occurs. Incident shocks of higher Mach number (e.g., M{sub i} = 2.0) focus the flow further towards the axis, leading to a stronger turbulent mixing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced Computational Modeling of High-Level Waste Vitrification at the Hanford Site

The U.S. Department of Energy (DOE) has selected vitrification for stabilizing legacy tank waste at the Hanford site, where radioactive waste from plutonium production was historically stored in underground tanks. This waste will be separated into low-activity waste (LAW) and high-level waste (HLW) fractions and processed at the Waste Treatment and Immobilization Plant (WTP). At WTP, glass melters are used for the vitrification of radioactive tank waste, transforming it into a stable borosilicate glass form for safe long-term storage. The melter vessel is constructed from highly durable and heat-resistant materials, where the vitrification process occurs. The main regions that are modeled are the melt pool, plenum, cold cap, riser/discharge chamber, and surrounding structure with insulation layers. Forced convection induced by air bubblers at the base of the melter ensure uniform temperature distribution and provide heat to the cold cap layer. The cold cap is a region of reacting batch feed that floats on top of the molten glass and is where the batch-to-glass reactions occur. Joule heating provided by electrodes mounted along the vertical walls of the melter and immersed directly in the glass, generates the necessary heat for the net endothermic conversion processes that occur in the cold cap. The high temperatures, radioactivity, and opaque nature of the glass prevent direct observation inside the melters. Therefore, computational models are essential for providing insight into factors that affect melter throughput. Thermocouples in the plenum provide operators with plenum temperature measurements. Operational adjustments include bubbling rate, voltage supplied to the electrodes, feed adjustments, and glass removal rate. Different computational fluid dynamics (CFD) models have been developed, each serving a specific purpose. There are CFD models of different scale melters, as well as models that capture the two-phase flow interfaces of rising bubbles in the molten glass or models with a simplified molten glass region so that the surrounding structure and plenum can be feasibly incorporated. Pilot-scale melter models have been developed to serve as validation of the methods employed in the simulation of the full-scale WTP melters. Models incorporating resolved bubbling are used to develop momentum source terms to implement into a single phase, multi-region, steady-state flow model that is being validated by measured process parameters such as glass production rate, voltage, input power, plenum temperatures, etc. The resolved bubbling model uses the multiphase volume of fluid approach to model the system with a high-resolution interface capturing scheme to maintain sharp interfaces between the molten glass and the air phase. The suite of CFD models is continually being improved to incorporate more realistic physics and achieve faster turnaround time. For example, an incremental controller is implemented to automatically adjust electrode voltage within the simulation to a molten glass set point temperature of 1150°C. Newer models feature improved meshes to ensure conformal meshes between regions and eliminate unnecessary mesh refinement in areas that are not of interest (such as boundary layers in offgas ports). Instead of explicitly modeling the structural, refractory, and insulation layers of the melter, a thermal resistance approach is used with published correlations used for boundary conditions. The development of robust and efficient CFD models will be instrumental in enabling the WTP to successfully fulfill its mission of safely stabilizing legacy nuclear waste.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Assessment of an E10 gasoline surrogate: Qualitative and quantitative comparisons of in-cylinder spray morphology

A minimum-component gasoline fuel surrogate that captures both chemical and physical behaviors of a full-distillate fuel is needed for high-fidelity CFD simulations. This study evaluates gasoline spray characteristics in a direct-injection spark-ignition engine under motored operation. Two fuels are compared; PACE-20, which is a 9-component surrogate formulation of RD5-87, is compared with its target fuel RD5-87, which is a full-boiling range research grade E10 gasoline. The spray morphologies of both fuels are recorded for a centrally-located direct-injection 8-hole spray subject to intake air cross-flow during the early part of the intake stroke. High-speed imaging recorded scattered light of the side and axial projections of the liquid spray. Quantitative metrics were developed and employed to facilitate comparison of spray morphologies as well as to identify the transition in spray morphology due to flash boiling. This paper builds on a previous study of RD5-87 where coolant temperature (20°C–100°C), in-cylinder pressure (40–110 kPa), engine speed (650–1950 rpm), and injection pressure (60–180 bar) were systematically changed to span operating conditions with and without flash boiling. Images of the PACE-20 morphology are selected for a sub-set of operating conditions from the previous study where distinctive morphology changes occurred. Visual inspection of the images and quantitative metrics demonstrate that the PACE-20 spray morphology is equivalent to that of the RD5-87 in most cases. The exception was for changes in the ambient-gas pressure where the flash-boiling transition occurred at ∼5 kPa higher in-cylinder pressure for PACE-20. Three empirical metrics, Merging Index, Asymmetry, and Flash Index are proposed here and they were found to be useful both as quantitative comparisons of the fuel morphologies, and for identifying the transition in spray morphology due to flash boiling.

Kim, Namho↗

Aeroheating Testing of the Mars Sample Return Earth Entry System with Surface Roughness

The Mars Sample Return Earth Entry System is a mission concept which would be the first NASA entry vehicle to utilize a woven thermal protection system as well as a 52.5 degree sphere-cone forebody geometry. Due to its novel design, historic experimental data sets were insufficient to validate the models used to characterize the expected aerothermal environment. A wind tunnel test campaign was funded by the Mars Sample Return Earth Entry System project in the NASA Langley 20-Inch Mach 6 Air Tunnel in order to obtain validation data. The December 2023 test entry of this campaign sought to obtain thermographic data to capture the impact of supersonic flow near woven surface roughness elements on convective heating augmentation, which was the largest remaining uncertainty in aerothermal design of the Earth Entry System. Data obtained were in family with prior results obtained on identical woven patterns without supersonic flow present at roughness elements, and it was found that this presence of supersonic flow did not have a noticeable effect on surface convective heating augmentation. Data were directly leveraged to support the NASA Mars Sample Return flight program and this data set is valuable for validating computational solutions on roughness-resolved grids.

Mars Sample Return↗

Aeroheating Testing of the Mars Sample Return Earth Entry System with Surface Roughness

The Mars Sample Return Earth Entry System is a mission concept which would be the first NASA entry vehicle to utilize a woven thermal protection system as well as a 52.5 degree sphere-cone forebody geometry. Due to its novel design, historic experimental data sets were insufficient to validate the models used to characterize the expected aerothermal environment. A wind tunnel test campaign was funded by the Mars Sample Return Earth Entry System project in the NASA Langley 20-Inch Mach 6 Air Tunnel in order to obtain validation data. The December 2023 test entry of this campaign sought to obtain thermographic data to capture the impact of supersonic flow near woven surface roughness elements on convective heating augmentation, which was the largest remaining uncertainty in aerothermal design of the Earth Entry System. Data obtained were in family with prior results obtained on identical woven patterns without supersonic flow present at roughness elements, and it was found that this presence of supersonic flow did not have a noticeable effect on surface convective heating augmentation. Data were directly leveraged to support the NASA Mars Sample Return flight program and this data set is valuable for validating computational solutions on roughness-resolved grids.

Mars Sample Return↗

Creep Behavior of Glass/Ceramic Sealant Used in Solid Oxide Fuel Cells

High operating temperature of solid oxide fuel cells require that sealant must function at high temperature between 600o and 900oC and in the oxidizing and reducing environments of fuel and air. It should be noted that creep deformation becomes relevant for a material when the operating temperature is near or exceeds half of its melting temperature (in degrees of Kelvin). The operating temperatures for most of the solid oxide fuel cells (SOFC) under development in the SECA program are around 800oC, which exceeds the glass transition temperature Tg for most glass ceramic materials. The goal of the study is to develop a creep model to capture the creep behavior of glass ceramic materials at high temperature and to investigate the effect of creep of glass ceramic sealant materials on stresses in glass seal and on the various interfaces of glass seal with other layers. The self-consistent creep models were incorporated into SOFC-MP and Mentat FC, and finite element analyses were performed to quantify the stresses in various parts. The stress in glass seals were released due to its creep behavior during the operating environments.

30 DIRECT ENERGY CONVERSION↗

Long-term nitrogen dioxide exposure assessment using back-extrapolation of satellite-based land-use regression models for Australia

Highlights: • We assessed how well a year-2006 satellite-based LUR model captures historical NO{sub 2}. • We used three methods to estimate annual mean NO{sub 2} during 1990–2005. • We measured their performance using standard LUR validation techniques. • Back-extrapolated 2006 levels captured up to 76% of spatial variability (90–05). Assessing historical exposure to air pollution in epidemiological studies is often problematic because of limited spatial and temporal measurement coverage. Several methods for modelling historical exposures have been described, including land-use regression (LUR). Satellite-based LUR is a recent technique that seeks to improve predictive ability and spatial coverage of traditional LUR models by using satellite observations of pollutants as inputs to LUR. Few studies have explored its validity for assessing historical exposures, reflecting the absence of historical observations from popular satellite platforms like Aura (launched mid-2004). We investigated whether contemporary satellite-based LUR models for Australia, developed longitudinally for 2006–2011, could capture nitrogen dioxide (NO{sub 2}) concentrations during 1990–2005 at 89 sites around the country. We assessed three methods to back-extrapolate year-2006 NO{sub 2} predictions: (1) ‘do nothing’ (i.e., use the year-2006 estimates directly, for prior years); (2) change the independent variable ‘year’ in our LUR models to match the years of interest (i.e., assume a linear trend prior to year-2006, following national average patterns in 2006–2011), and; (3) adjust year-2006 predictions using selected historical measurements. We evaluated prediction error and bias, and the correlation and absolute agreement of measurements and predictions using R{sup 2} and mean-square error R{sup 2} (MSE-R{sup 2}), respectively. We found that changing the year variable led to best performance; predictions captured between 41% (1991; MSE-R{sup 2} = 31%) and 80% (2003; MSE-R{sup 2} = 78%) of spatial variability in NO{sub 2} in a given year, and 76% (MSE-R{sup 2} = 72%) averaged over 1990–2005. We conclude that simple methods for back-extrapolating prior to year-2006 yield valid historical NO{sub 2} estimates for Australia during 1990–2005. These results suggest that for the time scales considered here, satellite-based LUR has a potential role to play in long-term exposure assessment, even in the absence of historical predictor data.

54 ENVIRONMENTAL SCIENCES↗