Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Determinants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

An MCMC determination of the primordial helium abundance

Spectroscopic observations of the chemical abundances in metal-poor H II regions provide an independent method for estimating the primordial helium abundance. H II regions are described by several physical parameters such as electron density, electron temperature, and reddening, in addition to y, the ratio of helium to hydrogen. It had been customary to estimate or determine self-consistently these parameters to calculate y. Frequentist analyses of the parameter space have been shown to be successful in these parameter determinations, and Markov Chain Monte Carlo (MCMC) techniques have proven to be very efficient in sampling this parameter space. Nevertheless, accurate determination of the primordial helium abundance from observations of H II regions is constrained by both systematic and statistical uncertainties. In an attempt to better reduce the latter, and continue to better characterize the former, we apply MCMC methods to the large dataset recently compiled by Izotov, Thuan, and Stasińska (2007). To improve the reliability of the determination, a high quality dataset is needed. In pursuit of this, a variety of cuts are explored. The efficacy of the He I λ4026 emission line as a constraint on the solutions is first examined, revealing the introduction of systematic bias through its absence. As a clear measure of the quality of the physical solution, a χ{sup 2} analysis proves instrumental in the selection of data compatible with the theoretical model. Nearly two-thirds of the observations fall outside a standard 95% confidence level cut, which highlights the care necessary in selecting systems and warrants further investigation into potential deficiencies of the model or data. In addition, the method also allows us to exclude systems for which parameter estimations are statistical outliers. As a result, the final selected dataset gains in reliability and exhibits improved consistency. Regression to zero metallicity yields Y{sub p} = 0.2534 ± 0.0083, in broad agreement with the WMAP result. The inclusion of more observations shows promise for further reducing the uncertainty, but more high quality spectra are required.

79 ASTRONOMY AND ASTROPHYSICS↗

A 3% DETERMINATION OF H {sub 0} AT INTERMEDIATE REDSHIFTS

Recent determinations of the Hubble constant, H {sub 0}, at extremely low and very high redshifts based on the cosmic distance ladder (grounded with trigonometric parallaxes) and a cosmological model (applied to Planck 2013 data), respectively, are revealing an intriguing discrepancy (nearly 9% or 2.4σ) that is challenging astronomers and theoretical cosmologists. In order to shed some light on this problem, here we discuss a new determination of H {sub 0} at intermediate redshifts (z ∼ 1), using the following four cosmic probes: (1) measurements of the angular diameter distances for galaxy clusters based on the combination of the Sunyaev-Zeldovich effect and X-ray data (0.14 ≤ z ≤ 0.89); (2) the inferred ages of old high redshift galaxies (0.62 ≤ z ≤ 1.70); (3) measurements of the Hubble parameter H(z) (0.1 ≤ z ≤ 1.8); and (4) the baryon acoustic oscillation signature (z = 0.35). In our analysis, assuming a flat ΛCDM cosmology and considering statistical plus systematic errors, we obtain H{sub 0}=74.1{sub −2.2}{sup +2.2} km s{sup –1} Mpc{sup –1} (1σ) which is a 3% determination of the Hubble constant at intermediate redshifts. We stress that each individual test adopted here has error bars larger than the ones appearing in the calibration of the extragalactic distance ladder. However, the remarkable complementarity among the four tests works efficiently in greatly reducing the possible degeneracy on the space parameter (Ω {sub m}, h), ultimately providing a value of H {sub 0} that is in excellent agreement with the determination using recessional velocities and distances to nearby objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Determining an unknown state of a high-dimensional quantum system with a single, factorized observable

One can uniquely identify an unknown state of a quantum system S by measuring a ''quorum'' consisting of a complete set of noncommuting observables. It is also possible to determine the quantum state by repeated measurements of a single and factorized observable, when the system S is coupled to an assistant system A whose initial state is known. This is because that the redistribution of the information about the unknown quantum state into the composite system A+S results in a one-to-one mapping between the unknown density matrix elements and the probabilities of the occurrence of the eigenvalues of a single, factorized observable of the composite system. Here we focus on quantum state tomography of high-dimensional quantum systems (e.g., a spin greater than 1/2) via a single observable. We determine the condition for the best determination and the upper bound to achieve the most robust measurements. From the experimental view we require a suitable interaction Hamiltonian to maximize the measure efficiency. For this we numerically investigate a three-level system. Moreover, the error analysis for the different-dimensional quantum states shows that the present measurement method is still very effective in determining an unknown state of a high-dimensional quantum system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Taming convergence in the determinant approach for x-ray excitation spectra

A determinant formalism in combination with ab initio calculations was proposed recently and has paved a way for simulating and interpreting x-ray excitation spectra in condensed-phase systems. The method systematically takes into account many-electron effects in the Mahan-Noziéres-De Dominicis (MND) theory, including core-level excitonic effects, the Fermi-edge singularity, shakeup excitations, and wave function overlap effects such as the orthogonality catastrophe, all within a universal framework using many-electron configurations. A heuristic search algorithm was introduced to search for the configurations that are important for defining the x-ray spectral line shape, instead of enumerating them in a brute-force way. The algorithm has proven to be efficient for calculating O K edges of transition metal oxides, which converge at the second excitation order (denoted as $f^{(n)}$ with n = 2), i.e., the final-state configurations with two e-h pairs (with one hole being the core hole). However, it remains unknown how the determinant x-ray spectra converge for general cases and at which excitation order n should one stop the determinant calculation. Even with the heuristic algorithm, the number of many-electron configurations still grows exponentially with the excitation order n. In this work we prove two theorems that can indicate the order of magnitude of the contribution of the $f^{(n)}$ configurations, so that one can estimate their contribution very quickly without actually calculating their amplitudes. The two theorems are based on singular-value decomposition (SVD) analysis, a method that is widely used to quantify entanglement between two quantum many-body systems. Finally, we examine the K edges of several metallic systems with the determinant formalism up to $f^{(5)}$ to illustrate the usefulness of the theorems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Variational description of the ground state of the repulsive two-dimensional Hubbard model in terms of nonorthogonal symmetry-projected Slater determinants

The few determinant (FED) methodology, introduced in our previous works for 1D lattices, is here adapted for the repulsive two-dimensional Hubbard model at half-filling and with finite doping fractions. Within this configuration mixing scheme, a given ground state with well defined spin and space group quantum numbers, is expanded in terms of a nonorthogonal symmetry-projected basis determined through chains of variation-after projection calculations. The results obtained for the ground state and correlation energies of half-filled and doped 4×4, 6×6, 8×8, and 10×10 lattices, as well as momentum distributions and spin-spin correlation functions in small lattices, compare well with those obtained using other state-of-the-art approximations. The structure of the intrinsic determinants resulting from the variational strategy is interpreted in terms of defects that encode information on the basic units of quantum fluctuations in the considered 2D systems. The varying nature of the underlying quantum fluctuations, reflected in a transition to a stripe regime for increasing onsite repulsions, is discussed using the intrinsic determinants belonging to a 16×4 lattice with 56 electrons. Such a transition is further illustrated by computing spin-spin and charge-charge correlation functions with the corresponding multireference FED wave functions. In good agreement with previous studies, the analysis of the pairing correlation functions reveals a weak enhancement of the extended s-wave and $d_x2-_y2$ pairing modes. Finally, given the quality of results here reported together with those previously obtained for 1D lattices and the parallelization properties of the FED scheme, we believe that symmetry projection techniques are very well suited for building ground state wave functions of correlated electronic systems, regardless of their dimensionality.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Distributions of the phase angle of the fermion determinant in QCD

The distribution of the phase angle and the magnitude of the fermion determinant as well as its correlations with the baryon number and the chiral condensate are studied for QCD at non zero quark chemical potential. Results are derived to one-loop order in chiral perturbation theory. We find that the distribution of the phase angle is Gaussian for small chemical potential and a periodic Lorentzian when the quark mass is inside the support of the Dirac spectrum. The baryon number and chiral condensate are computed as a function of the phase of the fermion determinant and we discuss the severe cancellations which occur upon integration over the angle. We compute the distribution of the magnitude of the fermion determinant as well as the baryon number and chiral condensate at fixed magnitude. Finally, we consider QCD in one Euclidean dimension where it is shown analytically, starting from the fundamental QCD partition function, that the distribution of the phase of the fermion determinant is a periodic Lorentzian when the quark mass is inside the spectral density of the Dirac operator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Unit-cell determination from randomly oriented electron-diffraction patterns

An algorithm is described that calculates the most likely primitive unit cell given a set of randomly oriented electron-diffraction patterns with unknown angular relationships. Unit-cell determination is the first step towards the structure solution of an unknown crystal form. Standard procedures for unit-cell determination cannot cope with data collections that consist of single diffraction patterns of multiple crystals, each with an unknown orientation. However, for beam-sensitive nanocrystals these are often the only data that can be obtained. An algorithm for unit-cell determination that uses randomly oriented electron-diffraction patterns with unknown angular relationships is presented here. The algorithm determined the unit cells of mineral, pharmaceutical and protein nanocrystals in orthorhombic high- and low-symmetry space groups, allowing (well oriented) patterns to be indexed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structure of Csd3 from Helicobacter pylori, a cell shape-determining metallopeptidase

H. pylori Csd3 (HP0506), together with other peptidoglycan hydrolases, plays an important role in determining cell shape. Its crystal structure in the latent state is reported. Helicobacter pylori is associated with various gastrointestinal diseases such as gastritis, ulcers and gastric cancer. Its colonization of the human gastric mucosa requires high motility, which depends on its helical cell shape. Seven cell shape-determining genes (csd1, csd2, csd3/hdpA, ccmA, csd4, csd5 and csd6) have been identified in H. pylori. Their proteins play key roles in determining the cell shape through modifications of the cell-wall peptidoglycan by the alteration of cross-linking or by the trimming of peptidoglycan muropeptides. Among them, Csd3 (also known as HdpA) is a bifunctional enzyme. Its d, d-endopeptidase activity cleaves the d-Ala{sup 4}-mDAP{sup 3} peptide bond between cross-linked muramyl tetrapeptides and pentapeptides. It is also a d, d-carboxypeptidase that cleaves off the terminal d-Ala{sup 5} from the muramyl pentapeptide. Here, the crystal structure of this protein has been determined, revealing the organization of its three domains in a latent and inactive state. The N-terminal domain 1 and the core of domain 2 share the same fold despite a very low level of sequence identity, and their surface-charge distributions are different. The C-terminal LytM domain contains the catalytic site with a Zn{sup 2+} ion, like the similar domains of other M23 metallopeptidases. Domain 1 occludes the active site of the LytM domain. The core of domain 2 is held against the LytM domain by the C-terminal tail region that protrudes from the LytM domain.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structure determination of an integral membrane protein at room temperature from crystals in situ

The X-ray structure determination of an integral membrane protein using synchrotron diffraction data measured in situ at room temperature is demonstrated. The structure determination of an integral membrane protein using synchrotron X-ray diffraction data collected at room temperature directly in vapour-diffusion crystallization plates (in situ) is demonstrated. Exposing the crystals in situ eliminates manual sample handling and, since it is performed at room temperature, removes the complication of cryoprotection and potential structural anomalies induced by sample cryocooling. Essential to the method is the ability to limit radiation damage by recording a small amount of data per sample from many samples and subsequently assembling the resulting data sets using specialized software. The validity of this procedure is established by the structure determination of Haemophilus influenza TehA at 2.3 Å resolution. The method presented offers an effective protocol for the fast and efficient determination of membrane-protein structures at room temperature using third-generation synchrotron beamlines.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Utilizing guanine-coordinated Zn 2+ ions to determine DNA crystal structures by single-wavelength anomalous diffraction

The experimental phase determination of crystal structures of nucleic acids and nucleic acid–ligand complexes would benefit from a facile method. Even for double-stranded DNA, software-generated models are generally insufficiently accurate to serve as molecular replacement search models, necessitating experimental phasing. Here, it is demonstrated that Zn 2+ ions coordinated to the N7 atom of guanine bases generate sufficient anomalous signal for single-wavelength anomalous diffraction (SAD) phasing of DNA crystal structures. Using zinc SAD, three crystal structures of double-stranded DNA oligomers, 5'-AGGGATCCCT-3', 5'-GGGATCCC-3' and 5'-GAGGCCTC-3', were determined. By determining the crystal structure of one of these oligomers, GAGGCCTC, in the presence of Mg 2+ instead of Zn 2+ , it was demonstrated that Zn 2+ is not structurally perturbing. These structures allowed the analysis of structural changes in the DNA on the binding of analogues of the natural product mithramycin to two of these oligomers, AGGGATCCCT and GAGGCCTC. Zinc SAD may become a routine approach for determining the crystal structures of nucleic acids and their complexes with small molecules.

DNA–drug complexes↗

An integrated approach for determining plutonium mass in spent fuel assemblies with nondestructive assay

There are a variety of reasons for quantifying plutonium (Pu) in spent fuel. Below, five motivations are listed: (1) To verify the Pu content of spent fuel without depending on unverified information from the facility, as requested by the IAEA ('independent verification'). New spent fuel measurement techniques have the potential to allow the IAEA to recover continuity of knowledge and to better detect diversion. (2) To assure regulators that all of the nuclear material of interest leaving a nuclear facility actually arrives at another nuclear facility ('shipper/receiver'). Given the large stockpile of nuclear fuel at reactor sites around the world, it is clear that in the coming decades, spent fuel will need to be moved to either reprocessing facilities or storage sites. Safeguarding this transportation is of significant interest. (3) To quantify the Pu in spent fuel that is not considered 'self-protecting.' Fuel is considered self-protecting by some regulatory bodies when the dose that the fuel emits is above a given level. If the fuel is not self-protecting, then the Pu content of the fuel needs to be determined and the Pu mass recorded in the facility's accounting system. This subject area is of particular interest to facilities that have research-reactor spent fuel or old light-water reactor (LWR) fuel. It is also of interest to regulators considering changing the level at which fuel is considered self-protecting. (4) To determine the input accountability value at an electrochemical processing facility. It is not expected that an electrochemical reprocessing facility will have an input accountability tank, as is typical in an aqueous reprocessing facility. As such, one possible means of determining the input accountability value is to measure the Pu content in the spent fuel that arrives at the facility. (5) To fully understand the composition of the fuel in order to efficiently and safely pack spent fuel into a long-term repository. The NDA of spent fuel can be part of a system that cost-effectively meets the burnup credit needs of a repository. Behind each of these reasons is a regulatory structure with MC&A requirements. In the case of the IAEA, the accountable quantity is elemental plutonium. The material in spent fuel (fissile isotopes, fission products, etc.) emits signatures that provide information about the content and history of the fuel. A variety of nondestructive assay (NDA) techniques are available to quantify these signatures. The effort presented in this paper is investigation of the capabilities of 12 NDA techniques. For these 12, none is conceptually capable of independently determining the Pu content in a spent fuel assembly while at the same time being able to detect the diversion of a significant quantity of rods. For this reason the authors are investigating the capability of 12 NDA techniques with the end goal of integrating a few techniques together into a system that is capable of measuring Pu mass in an assembly. The work described here is the beginning of what is anticipated to be a five year effort: (1) two years of modeling to select the best technologies, (2) one year fabricating instruments and (3) two years measuring spent fuel. This paper describes the first two years of this work. In order to cost effectively and robustly model the performance of the 12 NDA techniques, an 'assembly library' was created. The library contains the following: (a) A diverse range of PWR spent fuel assemblies (burnup, enrichment, cooling time) similar to that which exists in spent pools today and in the future. (b) Diversion scenarios that capture a range of possible rod removal options. (c) The spatial and isotopic detail needed to accurately quantify the capability of all the NDA techniques so as to enable integration. It is our intention to make this library available to other researchers in the field for inter-comparison purposes. The performance of each instrument will be quantified for the full assembly library for measurements in three different media: air, water and borated water. The 12 NDA techniques being researched are the following: Delayed Gamma, Delayed Neutrons, Differential Die-Away, Lead Slowing Down Spectrometer, Neutron Multiplicity, Nuclear Resonance Fluorescence, Passive Prompt Gamma, Passive Neutron Albedo Reactivity, Self-integration Neutron Resonance Densitometry, Total Neutron (Gross Neutron), X-Ray Fluorescence, {sup 252}Cf Interrogation with Prompt Neutron Detection.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Introductory guide to backgrounds in XPS spectra and their impact on determining peak intensities

Photoelectron and Auger peaks are central to most of the important uses of x-ray photoelectron spectroscopy (XPS), and thus, they receive the most attention in many types of analysis. Quantitative chemical analysis using XPS requires the assessment of the intensities of the photoemission peaks of the elements detected. Determination of peak intensities requires separation of the photoelectron peak signals from the background on which the peaks rest. For the determination of peak area intensities, the background is subtracted from overall signal intensity. The spectral background is also critical when peak fitting is used to determine intensities of overlapping peaks, and the model of background used in this process can impact the results. In addition to the impact on quantitative analysis, information about the depth distribution of elements in the near surface region can often be obtained by visual inspection of the background and quantified using appropriate modeling. Here, this introductory guide provides some basic information about backgrounds in the XPS analysis, describes the types of background models that are commonly used, suggests some of their strengths and weaknesses, and provides examples of their use and misuse. Although the fundamental nature of some components of the background signals in XPS is not understood, indicating that none of the models in use are fully correct and the area is subject to active research, appropriate good practices have been established for most routine analysis. The guide describes good practices, identifies errors that frequently appear in the literature, and uses examples to demonstrate the impacts of background selections on determinations of peak intensities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams

Monte Carlo simulations of x-ray beams typically take parameters of the electron beam in the accelerating waveguide to be free parameters. In this paper, a methodology is proposed and implemented to determine the energy, spectral width, and beam divergence of the electron source. All treatment head components were removed from the beam path, leaving only the exit window. With the x-ray target and flattener out of the beam, uncertainties in physical characteristics and relative position of the target and flattening filter, and in spot size, did not contribute to uncertainty in the energy. Beam current was lowered to reduce recombination effects. The measured dose distributions were compared with Monte Carlo simulation of the electron beam through the treatment head to extract the electron source characteristics. For the nominal 6 and 18 MV x-ray beams, the energies were 6.51{+-}0.15 and 13.9{+-}0.2 MeV, respectively, with the uncertainties resulting from uncertainties in the detector position in the measurement and in the stopping power in the simulations. Gaussian spectral distributions were used, with full widths at half maximum ranging from 20{+-}4% at 6 MV to 13{+-}4% at 18 MV required to match the fall-off portion of the percent-depth ionization curve. Profiles at the depth of maximum dose from simulations that used the manufacturer-specified exit window geometry and no beam divergence were 2-3 cm narrower than measured profiles. Two simulation configurations yielding the measured profile width were the manufacturer-specified exit window thickness with electron source divergences of 3.3 degree sign at 6 MV and 1.8 deg. at 18 MV and an exit window 40% thicker than the manufacturer's specification with no beam divergence. With the x-ray target in place (and no flattener), comparison of measured to simulated profiles sets upper limits on the electron source divergences of 0.2 deg. at 6 MV and 0.1 deg. at 18 MV. A method of determining source characteristics without mechanical modification of the treatment head, and therefore feasible in clinics, is presented. The energies and spectral widths determined using this method agree with those determined with only the exit window in the beam path.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determining the effects of microsphere and surrounding material composition on {sup 90}Y dose kernels using egsnrc and mcnp5

Purpose: Recent advances in the imaging of {sup 90}Y using positron emission tomography (PET) and improved uncertainty in the branching ratio for the internal pair production component of {sup 90}Y decay allow for a more accurate determination of the activity distribution of {sup 90}Y microspheres within a patient. This improved activity distribution can be convolved with the dose kernel of {sup 90}Y to calculate the dose distribution within a patient. This work investigates the effects of microsphere and surrounding material composition on {sup 90}Y dose kernels using egsnrc and mcnp5 and compares the results of these two transport codes. Methods: Monte Carlo simulations were performed with egsnrc and mcnp5 to calculate the dose rate at multiple radial distances around various {sup 90}Y sources. Point source simulations were completed with mcnp5 to determine the optimal electron transport settings for this work. After determining the optimal settings, point source simulations were completed using egsnrc (user code edknrc) and mcnp5 in water and liver [as defined by the International Commission on Radiation Units and Measurements (ICRU) Report 44]. The results were compared to ICRU Report 72 reference data. Point source simulations were also completed in water with a density of 1.06 g{center_dot}cm{sup -3} to evaluate the effect of the density of the surrounding material. Glass and resin microsphere simulations were performed with average and maximum diameter and density values (based on values given in the literature) in water and in liver. The results were compared to point source simulation results using the same transport code and in the same surrounding material. All simulations had statistical uncertainties less than 1%. Results: The optimal transport settings in mcnp5 for this work included using the energy-and step-specific algorithm (DBCN 17J 2) and ESTEP set to 10. These settings were used for all subsequent simulations with mcnp5. The point source simulations in water for both egsnrc and mcnp5 were found to agree within 2% of the ICRU 72 reference data over the investigated range. Point source simulations in liver had large differences relative to ICRU 72, approaching -60% near the maximum range of {sup 90}Y. These differences are mostly attributed to the difference in density between water (1.0 g{center_dot}cm{sup -3}) and liver (1.06 g{center_dot}cm{sup -3}). Glass and resin microsphere simulations showed a slight decrease in the dose rate near the maximum range of {sup 90}Y relative to the point source simulations. The largest relative differences were approximately -4.2% and -2.8% for the glass and resin microspheres, respectively. Agreement between the egsnrc and mcnp5 simulations results was generally good. Conclusions: The presence of the microsphere material causes slight differences in the {sup 90}Y dose kernel compared to those calculated with point sources. Large differences were seen between simulations in water and those in liver. For the most accurate calculation of the dose distribution, the density of the patient's liver should be accounted for in the calculation of the dose kernel. Lastly, due to the need to determine the optimal transport settings with mcnp5, electron transport with this code should be used with caution.

61 RADIATION PROTECTION AND DOSIMETRY↗

Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife{sup Registered-Sign} and linear accelerators equipped with microMLC and circular cones

Purpose: The use of small photon fields is now an established practice in stereotactic radiosurgery and radiotherapy. However, due to a lack of lateral electron equilibrium and high dose gradients, it is difficult to accurately measure the dosimetric quantities required for the commissioning of such systems. Moreover, there is still no metrological dosimetric reference for this kind of beam today. In this context, the first objective of this work was to determine and to compare small fields output factors (OF) measured with different types of active detectors and passive dosimeters for three types of facilities: a CyberKnife{sup Registered-Sign} system, a dedicated medical linear accelerator (Novalis) equipped with m3 microMLC and circular cones, and an adaptive medical linear accelerator (Clinac 2100) equipped with an additional m3 microMLC. The second one was to determine the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors introduced in a recently proposed small field dosimetry formalism for different active detectors.Methods: Small field sizes were defined either by microMLC down to 6 Multiplication-Sign 6 mm{sup 2} or by circular cones down to 4 mm in diameter. OF measurements were performed with several commercially available active detectors dedicated to measurements in small fields (high resolution diodes: IBA SFD, Sun Nuclear EDGE, PTW 60016, PTW 60017; ionizing chambers: PTW 31014 PinPoint chamber, PTW 31018 microLion liquid chamber, and PTW 60003 natural diamond). Two types of passive dosimeters were used: LiF microcubes and EBT2 radiochromic films.Results: Significant differences between the results obtained by several dosimetric systems were observed, particularly for the smallest field size for which the difference in the measured OF reaches more than 20%. For passive dosimeters, an excellent agreement was observed (better than 2%) between EBT2 and LiF microcubes for all OF measurements. Moreover, it has been shown that these passive dosimeters do not require correction factors and can then be used as reference dosimeters. Correction factors for the active detectors have then been determined from the mean experimental OF measured by the passive dosimeters.Conclusions: Four sets of correction factors needed to apply the new small field dosimetry formalism are provided for several active detectors. A protocol for small photon beams OF determination based on passive dosimeters measurements has been recently proposed to French radiotherapy treatment centers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Determination of lung segments in computed tomography images using the Euclidean distance to the pulmonary artery

Purpose: Computed tomography (CT) imaging is the modality of choice for lung cancer diagnostics. With the increasing number of lung interventions on sublobar level in recent years, determining and visualizing pulmonary segments in CT images and, in oncological cases, reliable segment-related information about the location of tumors has become increasingly desirable. Computer-assisted identification of lung segments in CT images is subject of this work.Methods: The authors present a new interactive approach for the segmentation of lung segments that uses the Euclidean distance of each point in the lung to the segmental branches of the pulmonary artery. The aim is to analyze the potential of the method. Detailed manual pulmonary artery segmentations are used to achieve the best possible segment approximation results. A detailed description of the method and its evaluation on 11 CT scans from clinical routine are given.Results: An accuracy of 2–3 mm is measured for the segment boundaries computed by the pulmonary artery-based method. On average, maximum deviations of 8 mm are observed. 135 intersegmental pulmonary veins detected in the 11 test CT scans serve as reference data. Furthermore, a comparison of the presented pulmonary artery-based approach to a similar approach that uses the Euclidean distance to the segmental branches of the bronchial tree is presented. It shows a significantly higher accuracy for the pulmonary artery-based approach in lung regions at least 30 mm distal to the lung hilum.Conclusions: A pulmonary artery-based determination of lung segments in CT images is promising. In the tests, the pulmonary artery-based determination has been shown to be superior to the bronchial tree-based determination. The suitability of the segment approximation method for application in the planning of segment resections in clinical practice has already been verified in experimental cases. However, automation of the method accompanied by an evaluation on a larger number of test cases is required before application in the daily clinical routine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The use of computed radiography plates to determine light and radiation field coincidence

Purpose: Photo-stimulable phosphor computed radiography (CR) has characteristics that allow the output to be manipulated by both radiation and optical light. The authors have developed a method that uses these characteristics to carry out radiation field and light field coincidence quality assurance on linear accelerators.Methods: CR detectors from Kodak were used outside their cassettes to measure both radiation and light field edges from a Varian linear accelerator. The CR detector was first exposed to a radiation field and then to a slightly smaller light field. The light impinged on the detector's latent image, removing to an extent the portion exposed to the light field. The detector was then digitally scanned. A MATLAB-based algorithm was developed to automatically analyze the images and determine the edges of the light and radiation fields, the vector between the field centers, and the crosshair center. Radiographic film was also used as a control to confirm the radiation field size.Results: Analysis showed a high degree of repeatability with the proposed method. Results between the proposed method and radiographic film showed excellent agreement of the radiation field. The effect of varying monitor units and light exposure time was tested and found to be very small. Radiation and light field sizes were determined with an uncertainty of less than 1 mm, and light and crosshair centers were determined within 0.1 mm.Conclusions: A new method was developed to digitally determine the radiation and light field size using CR photo-stimulable phosphor plates. The method is quick and reproducible, allowing for the streamlined and robust assessment of light and radiation field coincidence, with no observer interpretation needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-514: Simultaneously Determination of Radiation Isocentricity of Gantry, Collimator and Couch Using a Commercial Three-Dimensional Dosimetry QA Apparatus

Purpose: Radiation isocentricity is an important benchmark for a LINAC and is typically determined by 3 separate film star-shots. We developed a technique to simultaneously determine the radiation isocenter of gantry, collimator and couch with a commercial 3D QA apparatus. Methods: The ArcCHECK from SunNuclear was used on two LINACs. It was aligned with room lasers. For gantry rotation, collimator and couch were set to zero and gantry was placed to 0, 49, 213 and 311 degrees. Similarly, a set of collimator/couch angles were chosen with the other two axes at neutral positions. The measured dose matrices were analyzed by an in-house MATLAB program. For each shot, the central axis was determined by computing the FWHM of the diode arrays. The largest inscribed circle from these central axis lines was used to determine isocenter: the radius as the benchmark of isocentricity and the coordinates of the center as the discrepancy of radiation isocenter to the origin defined by lasers. To validate the method, the couch was shifted by ~5 mm in all three directions and measurements were repeated. Results: The radius of the largest inscribed circle for gantry, collimator and couch are (0.3, 0.5, 0.2) mm for one LINAC and (0.2, 0.3, 0.1) mm for the other, in agreement with the film star-shots at annual QA. The discrepancies of radiation isocenter are generally within 1 mm, except gantry rotation on one LINAC due to the drift of foot laser. The differences in positions detected are consistent with the intentional predefined shift. Conclusion: We have demonstrated a technique for the simultaneous measurement of gantry, collimator, and couch isocentricity with a set of carefully chosen irradiation parameters based on the specific construction geometry of the 3D detector ArcCheck. This can replace the standard film star-shots. The future work includes improving operation efficiency.

60 APPLIED LIFE SCIENCES↗