At least 631 records · Page 35

Integrated Cyber/Physical Grid Resiliency Modeling

This project explored coupling modeling and analysis methods from multiple domains to address complex hybrid (cyber and physical) attacks on mission critical infrastructure. Robust methods to integrate these complex systems are necessary to enable large trade-space exploration including dynamic and evolving cyber threats and mitigations. Reinforcement learning employing deep neural networks, as in the AlphaGo Zero solution, was used to identify "best" (or approximately optimal) resilience strategies for operation of a cyber/physical grid model. A prototype platform was developed and the machine learning (ML) algorithm was made to play itself in a game of 'Hurt the Grid'. This proof of concept shows that machine learning optimization can help us understand and control complex, multi-dimensional grid space. A simple, yet high-fidelity model proves that the data have spatial correlation which is necessary for any optimization or control. Our prototype analysis showed that the reinforcement learning successfully improved adversary and defender knowledge to manipulate the grid. When expanded to more representative models, this exact type of machine learning will inform grid operations and defense - supporting mitigation development to defend the grid from complex cyber attacks! This same research can be expanded to similar complex domains.

97 MATHEMATICS AND COMPUTING↗

Achieving Cyber-Resilience for Power Systems using a Learning, Model-Assisted Blockchain Framework

The secure integration and management of distributed energy resources (DER) and power aggregators in the electric grid requires secure communications and a physics-aware Command and Control (C2) strategy. A Blockchain (BC)-based overlay network was developed to provide a security layer for the existing power grid network that mitigates risks in current and legacy network and C2 protocols. By integrating a Model-Assisted Machine Learning (MAML) framework with a Secure Blockchain Overlay Network (SBON) a defense-in-depth strategy was achieved. In our approach, the MAML framework leveraged a smart contract framework to gather network data and learn the dynamics of DER to develop detection strategies for attacks targeting sensors and actuators used by DER. The MAML framework learned dynamical systems models for individual DERs to detect sensor attacks. For DER we utilized a Digital Twin (DT) to accelerate the learning process for a model resistant to stealthy attacks. The project created DT for PV inverters and BESS. The DTs were coupled with a model-assisted, data-driven learning of DER behavior. Specifically, we evaluated architectures for model-based learning with model-free fine-tuning. Additionally, differential privacy techniques were used to obfuscate data, while still allowing the computation of attack detection results based on obfuscated data. The SBON developed leverages a private permissioned blockchain network orchestrated with the Hyperledger Fabric framework. To connect the cyber world, which orchestrates the blockchain fabric, and the physical world where the power network resides, we developed a system implementation to enable the secure interaction of the physical world and the abstracted blockchain.

97 MATHEMATICS AND COMPUTING↗

Cyber-Physical Correlations for Infrastructure Resilience: A Game-Theoretic Approach

In several critical infrastructures, the cyber and physical parts are correlated so that disruptions to one affect the other and hence the whole system. These correlations may be exploited to strategically launch components attacks, and hence must be accounted for ensuring the infrastructure resilience, specified by its survival probability. We characterize the cyber-physical interactions at two levels: (i) the failure correlation function specifies the conditional survival probability of cyber sub-infrastructure given the physical sub-infrastructure as a function of their marginal probabilities, and (ii) the individual survival probabilities of both sub-infrastructures are characterized by first-order differential conditions. We formulate a resilience problem for infrastructures composed of discrete components as a game between the provider and attacker, wherein their utility functions consist of an infrastructure survival probability term and a cost term expressed in terms of the number of components attacked and reinforced. We derive Nash Equilibrium conditions and sensitivity functions that highlight the dependence of infrastructure resilience on the cost term, correlation function and sub-infrastructure survival probabilities. These results generalize earlier ones based on linear failure correlation functions and independent component failures. We apply the results to models of cloud computing infrastructures and energy grids.

cyber-physical infrastructures↗

Anomaly Detection and Mitigation for Dynamic Frequency Regulation in Hydropower-Battery Systems: Preprint

Hydropower operators and energy storage providers are increasingly interested in participating in frequency regulation services, driven by the incentives offered by independent system operators, such as the Pennsylvania-New Jersey-Maryland Interconnection (PJM), in a competitive electricity market. This transition, however, unfolds against the backdrop of a modernizing and rapidly digitizing power grid, exposing the integrated legacy infrastructure and vulnerable communication networks to a multitude of cybersecurity threats. These evolving threats not only endanger grid operations but also have the potential to trigger cascading disruptions across the broader grid network and influence regulation markets. This work presents an approach for developing an anomaly detection and mitigation system to address cybersecurity challenges during the participation of a hydropower-integrated battery energy storage system (BESS) in a frequency regulation market. The applied anomaly detector utilizes machine learning algorithms to provide detailed classification of cyber-physical events and provide a comprehensive situation awareness to grid operators. Later, the applied mitigation system triggers predefined corrective actions to minimize the impact of data integrity attacks on the regulation market and system stability. We evaluated the proposed approach on a fully active BESS topology using the slow regulation signal (Reg A) coming from the PJM market. Our simulation results reveal that the proposed approach performs well in detecting data integrity attacks within the allocated time frame and also minimizes the system's instability and economic loss during the participation of hydropower and BESS in the regulation market.

battery energy storage system↗

Protecting drinking water utilities from cyberthreats

Cyber-security challenges have the potential for becoming one of the defining issues of our time. Cyber-attacks have become an ever-increasing threat and the United States (US) Federal Bureau of Investigation (FBI) now ranks cyber-crime as one of its most important law enforcement activities. In addition to the general problems associated with cyber-crime, critical infrastructure (CI) related to energy production, manufacturing, water supply and other systems have come under attack. For example, drinking water utilities are increasingly incorporating computer technology into their routine operations and are therefore increasingly vulnerable to cyber- threats. Systems control and data acquisition (SCADA) systems used to manage automated physical processes essential to water treatment and distribution systems have become standard in medium to large drinking water utilities and in many small water systems. However, even with the application of standard information technology cybersecurity best practices these types of systems have proven to be vulnerable to cyber-attacks. In 2015, the US Department of Homeland Security (DHS) responded to 25 cybersecurity incidents in the Water Sector and to 46 incidents in the Energy Sector. Comparatively, between 2014 and 2015, the reported number of Water Sector incidents actually increased by 78.6% (from 14 to 25). The DHS is in a collaborative partnership with the US Environmental Protection Agency to ensure cybersecurity in the Water Sector. As a result of this partnership a number of guidance documents and techniques have been developed to counter cyber-attacks and minimize cyber vulnerability. These approaches are documented along with a summary of common vulnerabilities. However, a new approach which has great promise in protecting drinking water systems against hacking and cyber-attacks, based on the concept of unidirectional gateways, is presented and discussed.

99 GENERAL AND MISCELLANEOUS↗

Mediating Cyber and Physical Threat Propagation in Security Smart Grid Architectures

The power grid is a federated system. Regions of the system are controlled by different organizations and security of the grid is imposed from above through regulation of the security techniques used by the federants. This approach will be less effective as we move to a smart grid, where control of some elements of the grid rests in the customer’s home through technologies that enable remote access to appliances. These regions of the smart grid are less trusted, yet they interact in various ways with other parts of the grid. This paper demonstrates threat propagation in the smart grid from such regions, and discusses architectural approaches to mediating the impact of such flows.

Neuman, Clifford↗

Cyber–physical vulnerability and resiliency analysis for DER integration: A review, challenges and research needs

High penetration of renewable and sustainable Distributed Energy Resources (DER) into the traditional distribution system requires a well-coordinated control strategy for the improvement of system-wide reliability and resiliency. Implementation of such a holistic control architecture requires a flexible, near real-time, and bi-directional communication framework for facilitating the participation of various agents in a multi-vendor heterogeneous smart grid. While the sustainability of energy generation is ensured, this exposes the smart grid to extrinsic cyber threats, and appropriate defense mechanism(s) must be deployed to guarantee continued reliability and resiliency of the power grid. Further, the comprehensive literature review presented in this paper discusses the latest trends in the DER control schemes with fast communication requirements and their accompanying cyber–physical vulnerabilities. These control schemes are compared and contrasted for various traits. A three-level DER system architecture has been depicted, facilitating the deployment of these control schemes. The current developments of standard communication protocols, key security mechanisms, and best practices along major standards and guidelines are explored. The impacts of different attack types with miscellaneous DER functions based on various control schemes and associated mitigation solutions are also provided. Finally, challenges and future research directions for limiting cyber-power susceptibility to enhance resiliency are summarized. The work presented here will help us enabling a cyber-resilient and sustainable smart electric grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Physical Security (CPS) Extension to Air Traffic Management (ATM) Testbed

The Air Traffic Management (ATM) Testbed is being developed at NASA to enable benefit, impact, safety and cost assessments for accelerating the deployment of Concept and Technologies (C&T) in the National Airspace System (NAS). Today, C&T introduction into the NAS takes decades. The primary reason for this is an inability to assess the operational impact of the interaction between the proposed C&T and operationally deployed systems (Realistic Technologies) in terms of NAS-wide safety, traffic flow efficiency, roles and workload of controllers and traffic managers, and impact on airline fleet operations. Transition of C&T to operations requires mathematical modeling and simulation, Human-in-the-Loop (HITL) testing and shadow-mode evaluation driven by operational data. Whereas interaction with the operational system during testing and stages of deployment is not permissible due to safety concerns, it is certainly possible to create a simulation environment that closely mimics the NAS using the same operational systems/hardware for enabling such assessments. This presentation focuses on a proposed Cyber Physical Security extension to the ATM Testbed for creating a modeling and simulation architecture to study how well the Air Traffic Management system will perform and analyze effectiveness of mitigating security measures against particular cyber-attack scenarios.

Datta, Koushik↗

Load altering attack-tolerant defense strategy for load frequency control system

Cyber attacks are emerging threats to every information-oriented energy management system. By violating the cyber systems, the hacker can disrupt the security and stability due to the strong coupling between the cyber and physical facilities. In this paper, one type of cyber attacks designated as the load altering attack is studied for the power system frequency control, and corresponding defense strategies are proposed to improve the frequency control performance. Considering the difficulty of the application of model-based controller into large-scale power systems, a novel model-free defense framework is for the first time presented. Under this framework, both active defense and passive defense strategies are designed. The former assumes that the defender has the initiative to learn different attack scenarios. Adaptive defense strategies are implemented using the online attack identification information and off-line trained strategy pool. The latter assumes that the defender passively tolerates various attack scenarios via the pre-trained off-line strategy. Both approaches prove to be effective through validation based on the IEEE benchmark systems. The proposed defense framework and defense strategies can be extended to other energy control systems to enhance their attack tolerance capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydropower Cyber-Physical Configurations

The U.S. Department of Energy’s Water Power Technologies Office funded Pacific Northwest National Laboratory, Argonne National Laboratory, and the National Renewable Energy Laboratory to develop a typology to characterize the variety and pervasiveness of cyber-physical configurations across the nation’s hydropower fleet. Outreach to owners and operators returned configurations for 275 hydropower plants or approximately 12% of the fleet. Components (OT and IT), systems, and connections among systems differed among plants according to function, age, position in the river cascade, and many other factors. Seven cyber-physical configuration types labeled A through I, included from 2 to dozens of plants. They were differentiated by how pervasive data and control connections were among cyber-physical components and how frequently control signals paired with data signals in a feedback loop. The flow of data and control within each type implies what cybersecurity vulnerabilities may exist, and what mitigation actions may be most effective. A self-assessment approach allows plant operators to identify the configuration type similar to their plant and link to the lessons learned and best practices information. The cyber-physical typology reinforces the idea that hydropower facilities vary widely, but it also identifies groups that highlight similarities in how their cyber-physical components interact. This helps address fleetwide cybersecurity needs by identifying a reasonable number of configuration types that share risks, vulnerabilities, and potential mitigations.

13 HYDRO ENERGY↗

Data Centers and Digital Assurance Workshop 3 – Mitigations for Digital Assurance Risks

The third session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 18, 2025, focused on developing mitigation strategies for digital assurance risks identified in previous workshops. Hosted by Idaho National Laboratory (INL) and ScottMadden, the session emphasized the application of Cyber-Informed Engineering (CIE) to data center infrastructure, particularly at the utility–data center interface. Participants revisited and ranked key digital assurance risks, including architecture and interface weaknesses, governance gaps, and AI-enabled threats. The workshop introduced the 12 principles of CIE, advocating for consequence-focused design, engineered controls, and secure information architecture to proactively reduce cyber-physical vulnerabilities. These principles were applied to critical data center systems such as power distribution, UPS, cooling, SCADA/BMS, and grid-forming batteries. The session also addressed governance challenges at the interconnection boundary, highlighting the need for clear roles in telemetry sharing, firmware management, and trip settings. Special attention was given to emerging risks from behind-the-meter (BTM) generation, including reverse-power flow and the integration of small modular reactors (SMRs), which shift data centers from large loads to complex generation nodes. Participants explored how interconnection agreements can serve as enforceable instruments for digital assurance, and reviewed gaps in current standards such as NERC CIP, IEC 62443, and IEEE 1547. The workshop concluded with pathways to standardization, including model agreement language, state-level programs, and expanded NERC guidance. INL also presented tools and frameworks for secure procurement and supplier risk management, reinforcing the need for integrated engineering and policy solutions to secure the evolving data center–grid ecosystem. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

NASA IV&V's Cyber Range for Space Systems

A cyber range is a virtual environment that is used for cyberwarfare training and cyber technology development. It provides tools that help strengthen the stability, security and performance of cyber infrastructures and IT systems. NASA IV&V has created an adaptable virtual environment that is representative of a typical NASA mission system of systems environment that serves multiple purposes: Training of network defenders. Ability to perform simulated red vs blue training events. Ability to deploy mission specific technologies in a cyber contested environment. Ability to demonstrate vulnerabilities and their impact to ground and space systemsThe overall system is comprised of more than 70 virtual machines and physical infrastructure to demonstrate real-world cyber attacks against: email users, wireless networks, and physically implanted devices with command and control call-back. The cyber range was built to emulate a NASA precipitation satellite infrastructure.This presentation will give an overview of the virtual cyber range and how it was used to conduct a simulate red vs blue exercise with the goal of compromising the simulated spacecraft that utilizes real NASA flight software.

test and evaluation DT&E↗

Engineering Controls Database

Cyber-Informed Engineering (CIE) addresses the reality that cyber attacks on engineered systems can have consequences far beyond data loss or disruption of digital networks. When control systems are compromised, safety, reliability, and performance of the physical process itself may be threatened. This database is meant to establish clear examples and guidance for defining and applying engineered controls in CIE. It explains what engineered controls are, how they differ from information security measures, and how they are integrated into system design. The goal is to ensure that resilience is engineered into systems from the outset. Unlike cybersecurity protections that defend the digital layer, engineered controls act directly at the physical and algorithmic levels to guarantee that unacceptable consequences are prevented or limited. CIE keeps the consequences of a cyber attack from impacting the safety, reliability, and performance of engineered systems.

Source record↗

Cyber100 Compass: Quantification of Cybersecurity Risks for Systems Transitioning to High Levels of Renewables (Final Report)

The shift to high levels of renewable deployment will entail a significant re-engineering of the grid. As investors, utilities, customers, and others prepare for clean energy transitions, there is need to understand how restructuring the grid to accommodate renewables will change the attack surface of the grid and accompanying cyber risk. However, today the cyber-physical risks associated with electric grids incorporating high levels of renewable deployment remain largely unknown. The Cyber100 Compass proof-of-concept application attempts to quantify future cyber-physical security risks by combining risk data gathered from subject matter experts (SMEs) with input from system planners about conditions they expect to be true about their electric systems in the future. Users provide data about their organization’s tolerance for risk; the value they place on avoiding the consequences of different cyber events; and conditions that they expect to be true on their systems at some point in the future. The SMEs provide baseline probabilities for different cyber events; the probability that an event will be low-, moderate-, or high-impact; and the amount by which user-identified conditions on their systems will change the likelihood of the cyber events. The application takes both the user and SME input and performs a series of Monte Carlo simulations to arrive at a quantification of risk.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The NREL Cyber Range

With the National Renewable Energy Laboratory's (NREL's) cyber range, researchers can replicate cybersecurity scenarios as they would occur on real, complex energy systems. With supercomputing and advanced emulation capabilities, the cyber range allows users to build digital twins of real systems and connect the emulated environment to actual physical devices throughout NREL's laboratories. The space offers unlimited potential to test the frontier of energy systems security.

cyber range↗

Protecting Smart Buildings with STIG

This is a submission for the 2022 Intern Poster Session. The abstract of the poster is: Smart buildings are getting more common, and so are hackers that target them. The physical systems in our businesses and homes are now vulnerable to cyber attacks. Using STIG, an INL program that turns cybersecurity data into graphs, buildings can be better protected.

99 GENERAL AND MISCELLANEOUS↗

Water Security: Trends, Capabilities, and Research Directions to Secure Water Infrastructure

Water and wastewater sector is target rich and resource poor ~153k water utilities, serve 80% of US population ~16k publicly-owned wastewater systems in the US serve 75% of the population Need scalable solutions to fit small and medium to large systems Federal attention to critical infrastructure continues to grow – particularly in the water sector Increase in water sector incidents and threats for large scale disruption – particularly by nation-state actors and their proxies EPA is the SRMA DHS CISA focuses on critical infrastructure protection across sectors They must work together to secure WWW systems Research capabilities to enable secure water systems Current and future threats Resilience – natural disasters, accidents, cyber-physical attacks