Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Comparative Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Reducing radiation dose to the female breast during CT coronary angiography: A simulation study comparing breast shielding, angular tube current modulation, reduced kV, and partial angle protocols using an unknown-location signal-detectability metric

Purpose: The authors compared the performance of five protocols intended to reduce dose to the breast during computed tomography (CT) coronary angiography scans using a model observer unknown-location signal-detectability metric.Methods: The authors simulated CT images of an anthropomorphic female thorax phantom for a 120 kV reference protocol and five “dose reduction” protocols intended to reduce dose to the breast: 120 kV partial angle (posteriorly centered), 120 kV tube-current modulated (TCM), 120 kV with shielded breasts, 80 kV, and 80 kV partial angle (posteriorly centered). Two image quality tasks were investigated: the detection and localization of 4-mm, 3.25 mg/ml and 1-mm, 6.0 mg/ml iodine contrast signals randomly located in the heart region. For each protocol, the authors plotted the signal detectability, as quantified by the area under the exponentially transformed free response characteristic curve estimator (A-caret{sub FE}), as well as noise and contrast-to-noise ratio (CNR) versus breast and lung dose. In addition, the authors quantified each protocol's dose performance as the percent difference in dose relative to the reference protocol achieved while maintaining equivalent A-caret{sub FE}.Results: For the 4-mm signal-size task, the 80 kV full scan and 80 kV partial angle protocols decreased dose to the breast (80.5% and 85.3%, respectively) and lung (80.5% and 76.7%, respectively) with A-caret{sub FE} = 0.96, but also resulted in an approximate three-fold increase in image noise. The 120 kV partial protocol reduced dose to the breast (17.6%) at the expense of increased lung dose (25.3%). The TCM algorithm decreased dose to the breast (6.0%) and lung (10.4%). Breast shielding increased breast dose (67.8%) and lung dose (103.4%). The 80 kV and 80 kV partial protocols demonstrated greater dose reductions for the 4-mm task than for the 1-mm task, and the shielded protocol showed a larger increase in dose for the 4-mm task than for the 1-mm task. In general, the CNR curves indicate a similar relative ranking of protocol performance as the corresponding A-caret{sub FE} curves, however, the CNR metric overestimated the performance of the shielded protocol for both tasks, leading to corresponding underestimates in the relative dose increases compared to those obtained when using the A-caret{sub FE} metric.Conclusions: The 80 kV and 80 kV partial angle protocols demonstrated the greatest reduction to breast and lung dose, however, the subsequent increase in image noise may be deemed clinically unacceptable. Tube output for these protocols can be adjusted to achieve a more desirable noise level with lesser breast dose savings. Breast shielding increased breast and lung dose when maintaining equivalent A-caret{sub FE}. The results demonstrated that comparisons of dose performance depend on both the image quality metric and the specific task, and that CNR may not be a reliable metric of signal detectability.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-14: A Comparative Study Between Forward and Inverse Planning in Gamma Knife Radiosurgery for Acoustic Neuroma Tumours

Purpose: To evaluate forward and inverse planning methods for acoustic neuroma cases treated in Gamma Knife Perfexion. Methods: Five patients with acoustic neuroma tumour abutting brainstem were planned twice in LGP TPS (Version 10.1) using TMR10 algorithm. First plan was entirely based on forward planning (FP) in which each shot was chosen manually. Second plan was generated using inverse planning (IP) for which planning parameters like coverage, selectivity, gradient index (GI) and beam-on time threshold were set. Number of shots in IP was automatically selected by objective function using iterative process. In both planning methods MRI MPRAGE sequence images were used for tumour localization and planning. A planning dose of 12Gy at 50% isodose level was chosen. Results and Discussion: Number of shots used in FP was greater than IP and beam-on time in FP was in average 1.4 times more than IP. One advantage of FP was that the brainstem volume subjected to 6Gy dose (25% isodose) was less in FP than IP. Our results showed use of more number of shots as in FP results in GI less than or equal to 2.55 which is close to its lower limit. Dose homogeneity index (DHI) analysis of FP and IP showed average values of 0.59 and 0.67 respectively. General trend in GK for planning in acoustic neuroma cases is to use small collimator shots to avoid dose to adjacent critical structures. More number of shots and prolonged treatment time causes inconvenience to the patients. Similarly overuse of automatic shot shaping as in IP results in increased scatter dose. A compromise is required in shot selection for these cases. Conclusion: IP method could be used in acoustic neuroma cases to decrease treatment time provided the source sector openings near brainstem are shielded or adjusted appropriately to reduce brainstem dose.

60 APPLIED LIFE SCIENCES↗

Comparative study of solute trapping and Gibbs free energy changes at the phase interface during alloy solidification under local nonequilibrium conditions

An analytical model has been developed to describe the influence of solute trapping during rapid alloy solidification on the components of the Gibbs free energy change at the phase interface with emphasis on the solute drag energy. For relatively low interface velocity V < V{sub D}, where V{sub D} is the characteristic diffusion velocity, all the components, namely mixing part, local nonequilibrium part, and solute drag, significantly depend on solute diffusion and partitioning. When V ≥ V{sub D}, the local nonequilibrium effects lead to a sharp transition to diffusionless solidification. The transition is accompanied by complete solute trapping and vanishing solute drag energy, i.e. partitionless and “dragless” solidification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparative study of the scalar- and tensor-meson production in the reaction γγ{sup *} (Q{sup 2})→ ηπ{sup 0}

The cross section for the reaction γγ{sup *} (Q{sup 2})→ ηπ{sup 0} was predicted on the basis of a simultaneous analysis of data from the Belle detector (Japan) on the reaction γγ → ηπ{sup 0} and data the KLOE detector (Italy) on the decay process ϕ → ηπ{sup 0}γ. The production of a{sub 0}(980) scalar and a{sub 2}(1320) tensor mesons was studied in detail. It is shown that the QCD-predicted asymptotic behavior of the cross section for the process γ{sup *}(Q{sup 2})γ → a{sub 2}(1320) → ηπ{sup 0} can be reproduced only upon taking into account the compensation of the contributions of ρ(770) and ω(782) mesons in the leading order by the contributions of their radial excitations in the Q{sup 2} channel. It is expected that, at large Q{sup 2}, the cross section is dominated by the a{sub 2}(1320) contribution, but that, at Q{sup 2} = 0, the a{sub 2}(1320) contribution is commensurate with the scalarmeson contribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparative study of X-ray emission from plasma focus relative to different preionization schemes

A 2.7-kJ Mather-type plasma focus has been investigated for X-ray emission with preionization produced by an α-source, a β-source, and a shunt resistor. Time-resolved and time integrated measurements are carried out using a PIN-diode-based X-ray spectrometer and pinhole camera. The β-source ({sub 28}Ni{sup 63}) assisted preionization enhances the X-ray emission up to 25%, while preionization induced by depleted uranium ({sub 92}U{sup 238}) increases both Cu-K{sub α} and total X-ray yield of about 100%. The preionization caused by the optimum shunt resistor enhances the Cu-K{sub α} and total X-ray yield of about 53%. It is found that preionization also broadens the working pressure range for the high X-ray yield and improves the shot-to-shot reproducibility of the system. Pinhole images reveal that the X-ray emission from the anode tip is dominant owing to impact of electron bombardment, while the X-ray emission from hot spots is also visible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative study of 3C-SiC layers sublimation-grown on a 6H-SiC substrate

n-3C-SiC/n-6H-SiC heterostructures grown by vacuum sublimation on CREE commercial 6H-SiC substrates are studied. Transmission electron microscopy (TEM) demonstrated that a transitional layer of varying thickness, composed of a mixture of 3C- and 6H-SiC polytypes, is formed on the substrate. A 3C polytype layer was obtained on the interlayer. Cathodoluminescence study of the surface of the film demonstrated that defects in the form of inclusions of another phase (6H-polytype), stacking faults, and twin boundaries (separating domains of cubic modification, grown in various orientations) are found on the surface and in the surface layer with a thickness on the order of 100 {mu}m. Varying the growth conditions changes the concentration of various types of defects.

36 MATERIALS SCIENCE↗

A comparative study on the electronic and optical properties of Sb{sub 2}Se{sub 3} thin film

The thin film of Sb{sub 2}Se{sub 3} was deposited by thermal evaporation method and the film was annealed in N{sub 2} flow in a three zone furnace at a temperature of 290°С for 30 min. The structural properties were characterized by scanning electron microscopy (SEM), transmission electron microscopy (ТЕМ), X-ray diffraction (XRD) and Raman spectroscopy, respectively. It is seen that the as-deposited film is amorphous and the annealed film is polycrystalline in nature. The surface of Sb{sub 2}Se{sub 3} film is oxidized with a thickness of 1.15 nm investigated by X-ray photolecetron spectroscopy (XPS) measurement. Spectroscopic ellipsometry (SE) and UV–vis spectroscopy measurements were carried out to study the optical properties of Sb{sub 2}Se{sub 3} film. In addition, the first principles calculations were applied to study the electronic and optical properties of Sb{sub 2}Se{sub 3}. From the theoretical calculation it is seen that Sb{sub 2}Se{sub 3} is intrinsically an indirect band gap semiconductor. Importantly, the experimental band gap is in good agreement with the theoretical band gap. Furthermore, the experimental values of n, k, ε{sub 1}, and ε{sub 2} are much closer to the theoretical results. However, the obtained large dielectric constants and refractive index values suggest that exciton binding energy in Sb{sub 2}Se{sub 3} should be relatively small and an antireflective coating is recommended to enhance the light absorption of Sb{sub 2}Se{sub 3} for thin film solar cells application.

36 MATERIALS SCIENCE↗

Comparative study of the spectral and structural properties of EuAl{sub 3}(BO{sub 3}){sub 4} single crystals with different morphologies

Europium alumoborate EuAl{sub 3}(BO{sub 3}){sub 4} microcrystals have been synthesized by the flux method at a temperature of 1050°C. The obtained crystals have different morphologies: both plane-faced and skeletal microcrystals have been observed. Infrared spectroscopy, cathodeluminescence, and transmission electron microscopy investigations of individual microcrystals showed that the spectral and structural characteristics of these morphological forms coincide. The obtained crystals are characterized by the rhombohedral symmetry (sp. gr. R32) with the inclusions of C2/c monoclinic phase domains.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparative study of quarkonium transport in hot QCD matter

This document summarizes the efforts of the EMMI Rapid Reaction Task Force on “Suppression and (re)generation of quarkonium in heavy-ion collisions at the LHC”, centered around their 2019 and 2022 meetings. It provides a review of existing experimental results and theoretical approaches, including lattice QCD calculations and semiclassical and quantum approaches for the dynamical evolution of quarkonia in the quark-gluon plasma as probed in high-energy heavy-ion collisions. The key ingredients of the transport models are itemized to facilitate comparisons of calculated quantities such as reaction rates, binding energies, and nuclear modification factors. A diagnostic assessment of the various results is attempted and coupled with an outlook for the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A density functional theory based comparative study of hybrid photoemissions from Cl@C 60 , Br@C 60 and I@C 60

Photoionization from atom-C 60 hybrid levels in halogen endofullerene molecules, Cl@C 60 , Br@C 60 and I@C 60 , are calculated using a linear response density functional method. Both the ordinary electron-configuration where the open shell halogen is at the center of C 60 and the stable configuration after the atom receives an electron from C 60 to form a closed shell anion are considered. Similar ground state hybridization is found for all three systems while, in general, a slight weakening of the effect is noticed after the electron transfer. At lower photon energies, cross sections of the outer hybrid levels attain identical shapes from enhancements driven by the C 60 plasmon resonances, while the higher energy emissions remain distinguishable from the differences in atomic responses. These results further show near insensitivity to the choice of a configuration. The inner hybrid cross sections in general exhibit similar overall structures, although differ in details between molecules. Furthermore, for these states the results significantly differ before and after the electron transfer – a feature that can be useful to experimentally determine the real configuration of the molecules via photoelectron spectroscopy.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Comparative Study of Imidazolium-Based Ionic Liquid-Single-Walled Carbon Nanotube Composites with Enhanced Conductivity Properties for Supercapacitor Applications

Mixtures of ionic liquids (ILs) containing single-walled carbon nanotubes (SWCNTs) were prepared and characterized to obtain electrolytes with optimized transport properties for use in energy storage devices such as supercapacitors. Imidazolium ILs bearing cations with side chains of different functionality coupled with bis(trifluoromethylsulfonyl)amide (NTf 2- ) or bis(fluorosulfonyl)-amide (FSA-) anions, were used in mixtures containing up to 5 wt% SWCNTs. At and above 2 wt% nanotube loading, the mixtures exhibited higher conductivities than the pure ILs, in spite of the extremely high viscosities. Loadings of 5 wt% produced very high conductivities, and studies of the temperature dependence indicated a change in the charge transport mechanism between 2 and 5 wt% loading. At 5 wt% loading, the highest conductivities (up to 540 mS/cm at 25 °C) were obtained for the ILs containing the NTf 2- anion. Overall, these results can significantly contribute to the development of improved energy storage devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Comparative Study of Degradation Behaviors of LiFePO 4 , LiMn 2 O 4 , and LiNi 0.8 Mn 0.1 Co 0.1 O 2 in Different Aqueous Electrolytes

Aqueous Li-ion batteries (ALIBs) are an important class of battery chemistries owing to the intrinsic non-flammability of aqueous electrolytes. However, water is detrimental to most cathode materials and could result in rapid cell failure. Identifying the degradation mechanisms and evaluating the pros and cons of different cathode materials are crucial to guide the materials selection and maximize their electrochemical performance in ALIBs. Here, in this study, we investigate the stability of LiFePO 4 (LFP), LiMn 2 O 4 (LMO) and LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC) cathodes, without protective coating, in three different aqueous electrolytes, i.e., salt-in-water, water-in-salt, and molecular crowding electrolytes. The latter two are the widely reported "water-deficient electrolytes." LFP cycled in the molecular crowding electrolyte exhibits the best cycle life in both symmetric and full cells owing to the stable crystal structure. Mn dissolution and surface reduction accelerate the capacity decay of LMO in water-rich electrolyte. On the other hand, the bulk structural collapse leads to the degradation of NMC cathodes. LMO demonstrates better full-cell performance than NMC in water-deficient aqueous electrolytes. LFP is shown to be more promising than LMO and NMC for long-cycle-life ALIB full cells, especially in the molecular crowding electrolyte. However, none of the aqueous electrolytes studied here provide enough battery performance that can compete with conventional non-aqueous electrolytes. This work reveals the degradation mechanisms of olivine, spinel, and layered cathodes in different aqueous electrolytes and yields insights into improving electrode materials and electrolytes for ALIBs.

36 MATERIALS SCIENCE↗

Narrow-Band Imaging Improves Detection of Colorectal Peritoneal Metastases: A Clinical Study Comparing Advanced Imaging Techniques

Background: Colorectal peritoneal metastases (PM) are often diagnosed in an advanced disease stage. Cytoreduction and hyperthermic intraperitoneal chemotherapy (HIPEC) improve survival of patients with colorectal PM, although most benefit is seen in patients with limited peritoneal disease. Advanced imaging techniques might improve the detection of PM, potentially leading to earlier diagnosis and improved cytoreduction. This prospective clinical trial compared three advanced techniques with conventional white-light imaging for the detection of colorectal PM: narrow-band imaging (NBI), near-infrared indocyanine green fluorescent imaging (NIR-ICG), and spray-dye chromoendoscopy (SDCE). Methods: Patients with colorectal PM were prospectively included. Prior to cytoreduction and HIPEC, all abdominal regions were inspected with white-light imaging, NBI, NIR-ICG, and SDCE during exploratory laparoscopy. Primary endpoints were sensitivity and specificity for the detection of PM, using pathological examination of biopsied lesions as the reference standard. The safety of all techniques was assessed. Results: Between May 2016 and March 2018, four different techniques were analyzed in 28 patients, resulting in 169 biopsies. Sensitivity for the detection of PM significantly increased from 80.0% with white light to 96.0% with NBI (p = 0.008), without loss of specificity (74.8% vs. 73.1%, respectively, p = 0.804). The use of NIR-ICG and SDCE was discontinued after 10 patients had undergone treatment because the lesions were not fluorescent using NIR-ICG, and because SDCE did not visualize the whole peritoneum. No adverse events relating to the imaging techniques occurred. Conclusion: NBI substantially increased the detection of PM. This method is safe and could improve the detection of metastatic lesions and help optimize cytoreduction in patients with colorectal PM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparative Study of Multi-material Data Structures for Computational Physics Applications

The data structures used to represent the multi-material state of a computational physics application can have a drastic impact on the performance of the application. We look at efficient data structures for sparse applications where there may be many materials, but only one or few in most computational cells. We develop simple performance models for use in selecting possible data structures and programming patterns. We verify the analytic models of performance through a small test program of the representative cases.

97 MATHEMATICS AND COMPUTING↗

A comparative study on wave prediction for WECs

The idea of acausality for control of a wave energy converter (WEC) is a concept that has been popular since the birth of modern wave energy research in the 1970s. This concept has led to considerable research into wave prediction and feedforward WEC control algorithms. However, the findings in this report mostly negate the need for wave prediction to improve WEC energy absorption, and favor instead feedback driven control strategies. Feedback control is shown to provide performance that rivals a prediction-based controller, which has been unrealistically assumed to have perfect prediction. It is well known in classical control engineering that perfect knowledge of past and future events will always lead to higher performing systems. However, it is also well known that the underlying system must be well-designed; control cannot fix a bad design. Additionally, one must consider the practical application of a control design, which relies on measurements and actuation systems. There are major implications to cost and reliability when relying on remote sensors requiring real-time data-streaming (e.g., remote wave buoys). This report shows that for a well-designed WEC, in which closed loop dynamics is considered since early stages of design, a suboptimal controller using no prediction can achieve more than 90% of the theoretical maximum. A predictionless feedback resonating (FBR) controller performs within 0.1% percent of a controller with perfect future knowledge (something which is not practically attainable). Given the major challenges with accurate and robust wave prediction, this result provides a major argument and incentive for utilizing feedback for WEC control. Implementation of these feedback strategies is readily attainable, while the strategy requiring perfect wave prediction will demand an unknown number of additional years to research and develop, all in the service of a marginal 1% benefit.

16 TIDAL AND WAVE POWER↗

A comparative study on wave prediction for WECs

The idea of acausality for control of a wave energy converter (WEC) is a concept that has been popular since the birth of modern wave energy research in the 1970s. This concept has led to considerable research into wave prediction and feedforward WEC control algorithms. However, the findings in this report mostly negate the need for wave prediction to improve WEC energy absorption, and favor instead feedback driven control strategies. Feedback control is shown to provide performance that rivals a prediction-based controller, which has been unrealistically assumed to have perfect prediction.

16 TIDAL AND WAVE POWER↗