Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Endovascular Coil Embolization in a Postnephrostomy Renal Vein to Renal Pelvis Fistula

We report the case of a 74-year-old man with post-percutaneous-nephrostomy venous hemorrhage from an iatrogenic fistula between the renal pelvis and a large tributary of the renal vein. Conservative management failed to contain the hemorrhage. Hence the fistula was occluded by coil embolization through the renal vein. This endovascular approach enabled rapid and effective stoppage of the venous bleed.There was no recurrence of the bleed or any pertinent complication at 3-month follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Systemic Arterial Supply to the Normal Basal Segments of the Left Lower Lobe of the Lung-Treatment by Coil Embolization-and a Literature Review

We report the case of a 24-year-old woman with systemic arterial supply to the normal basal segments of the left lower lobe of the lung. She experienced repeated episodes of hemoptysis. In this patient, the normal pulmonary arteries were absent in the affected segments. The aberrant artery arising from the descending thoracic aorta was embolized using metallic coils. The patient's recovery was uneventful, except that she had mild chest pain for 3 days after the procedure. Her symptom has not recurred since 1 year follow-up. Although proximal occlusion of the aberrant artery was observed, pulmonary infarction or necrosis of the affected segments was not shown on follow-up computed tomography. Transarterial embolization can be an alternative treatment option for patients with this rare congenital anomaly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interlocking Detachable Coil Embolization by Technique of Dumbbell-Shaped Framing and Filling and Bridge Formation Under Balloon Dilatation for Huge Conglomerate Pulmonary Arteriovenous Malformation

A 60-year-old woman presented with a conglomerate pulmonary arteriovenous malformation (PAVM) size 8.2 Multiplication-Sign 7.2 cm on chest X-ray. Feeding arteries were A{sub a}{sup 7} and A{sub b}{sup 7}, A{sup 8}, and A{sup 10}. The diameter and length of the A{sub b}{sup 7} neck were 15.5 and 16 mm, respectively. After percutaneous transcatheter embolization of A{sup 8} and A{sup 10}, PTE of A{sub a}{sup 7} and A{sub b}{sup 7} was conducted under balloon occlusion with interlocking detachable coils using a technique of dumbbell-shaped framing and filling, making a bridge from A{sub b}{sup 7} to the trunk of A{sup 9} and A{sup 10}across A{sup 7}. Follow-up computed tomography 10 months after treatment showed marked shrinkage of the PAVM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Covered Stent and Coils Embolization of a Pulmonary Artery Pseudoaneurysm After Gunshot Wound

We report the first case of endovascular covered stent implantation for the treatment of a large pulmonary artery pseudoaneurysm (PAPA) following a right thoracic gunshot wound. After resuscitation and hemodynamic stabilization, a CT angiography was performed to analyze the neck size of the PAPA and its position relative to the branches of the parent artery. Covered stent implantation with additional coil embolization was successfully performed. At the 4-year follow-up, the stents remained patent and there was neither pseudoaneurysm recurrence nor treatment-related complication.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Endovascular Treatment with Distal Radial Artery Coil Embolization and Angioplasty in Steal Syndrome Associated with Forearm Dialysis Fistula

PurposeThe present study was performed to define the results of the endovascular treatment with angioplasty and distal radial artery embolization in ischemic steal syndrome associated with forearm arteriovenous accesses.MethodThe cases referred to our interventional radiology unit with symptoms and physical examination findings suggestive of ischemic steal syndrome were retrospectively evaluated first by Doppler ultrasonography, and then by angiography. Cases with proximal artery stenosis were applied angioplasty, and those with steal syndrome underwent coil embolization to distal radial artery.ResultsOf 589 patients who underwent endovascular intervention for dialysis arteriovenous fistulae (AVF)-associated problems, 6 (1.01 %) (5 female, 1 males; mean age 62 (range 41–78) with forearm fistula underwent combined endovascular treatment for steal syndrome. In addition to steal phenomenon, there were stenosis and/or occlusion in proximal radial and/or ulnar artery in 6 patients concurrently. Embolization of distal radial artery and angioplasty to proximal arterial stenoses were performed in all patients. Ischemic symptoms were eliminated in all patients and the AVF were in use at the time of study. In one patient, ischemic symptoms recurring 6 months later were alleviated by repeat angioplasty of ulnar artery.ConclusionIn palmar arch steal syndrome affecting forearm fistulae, combined distal radial embolization and angioplasty is also an effective treatment method in the presence of proximal radial and ulnar arterial stenoses and occlusions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transapical Coil Embolization of a Postsurgical Ascending Thoracic Aortic Pseudoaneurysm

Ascending aortic pseudoaneurysms are a rare but potentially life-threatening complication of aortic root or cardiac surgery. Surgical repair is established as first-line treatment; however, patient comorbidities, technical considerations, and anatomic limitations often preclude patients from repeat surgery, thus necessitating alternative approaches. Here, we present a case of coil embolization of an ascending aortic pseudoaneurysm via a transapical approach in a particularly complex scenario where percutaneous and peripheral access was technically unfeasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Scale Spallation During Coiling on the Electrochemical and Pickling Behavior of a Hot-Rolled Dual-Phase Steel

Tertiary oxide scale consists of magnetite and hematite, and in dual-phase steel strips were observed after the exit of final rolling stand in a thin slab casting rolling (TSCR) mill. Microscopic observation confirmed that these scales cracked and spalled off from many places of surface during coiling causing a non-uniform oxide layer on the steel surface. The present work discusses the synergistic effect of such non-uniform oxide layer and run-out-table cooling water on the electrochemical behavior of the dual-phase steel. The electrochemical response was assessed with the help of dynamic and linear polarization tests considering cooling water as electrolyte. The presence of non-uniform scale produced high cathodic (scaled zone) to anodic (spalled-off zone) area ratio that eventually led to extensive pitting corrosion in the present steel. Furthermore, the pickling behavior of the steel was also studied in detail. It was observed that the steel surface, with spalled-off area of about one-tenth of total surface area, corroded preferentially 3-4 times faster at spalled-off area than that of the uniformly pickled surface. The characterization study was performed using scanning electron microscopy, confocal laser 3D scanning microscopy, x-ray diffraction and Raman spectroscopy in order to establish the reasons for pitting corrosion due to the scale spallation.

36 MATERIALS SCIENCE↗

On the mechanical behavior of a Nb 3 Sn superconducting coil during a quench: Two-dimensional finite element analysis of a quench heater protected magnet

New high-field accelerator magnets based on $Nb_3Sn$ superconductors are pushing the boundaries of magnet design and quench protection towards new limits. While their large stored energies and current densities result in a very challenging scenario for magnet protection, their great electromagnetic forces create also new requirements in terms of magnet design and stress management techniques. Furthermore, the strain sensitivity of $Nb_3Sn$ cables turns the electro-mechanical limits of the conductor into a parameter of the highest importance, where conductor degradation becomes a critical aspect in magnet operation. The coupling of all the above-mentioned considerations during quench is a case of special interest that adds further complexity to the design of $Nb_3Sn$ magnets. The objective of this paper is to provide a complete two-dimensional investigation of the coil and magnet structure mechanics during a quench event. Here, the analysis is performed using a combination of finite element codes that provide the necessary input for the mechanical study. The core of the modelling strategy relies on a thermal-electric model, whose results are directly used as loads in the mechanical simulation. In doing so, the stress evolution during and after a quench is obtained. We focus for this time in the analysis of a quench heater protected magnet, where dynamic effects are of less importance in contrast to other protection systems like CLIQ.

43 PARTICLE ACCELERATORS↗

Tumor Volume and Metabolism of Prostate Cancer Determined by Proton Magnetic Resonance Spectroscopic Imaging at 3T Without Endorectal Coil Reveal Potential Clinical Implications in the Context of Radiation Oncology;Prostate cancer; Magnetic resonance spectroscopic imaging; Radiation oncology; Tumor volume; Biomarkers

Purpose: To determine whether a relationship exists between the tumor volume (TV) or relative choline content determined using magnetic resonance spectroscopy imaging (MRSI) at 3T and the clinical prognostic parameters for patients with localized prostate cancer (PCa). Methods and Materials: A total of 72 men (mean age, 67.8 {+-} 6.2 years) were stratified as having low-risk (n = 26), intermediate-risk (n = 24), or high-risk (n = 22) PCa. MRSI was performed at 3T using a phased-array coil. Spectra are expressed as the total choline/citrate, total choline plus creatine/citrate, and total choline plus polyamines plus creatine/citrate ratios. The mean ratio of the most pathologic voxels and the MRSI-based TV were also determined. Results: The mean values of the total choline/citrate, total choline plus creatine/citrate, and total choline plus polyamine plus creatine/citrate ratios were greater for Stage T2b or greater tumors vs. Stage T2a or less tumors: 7.53 {+-} 13.60 vs. 2.31 {+-} 5.65 (p = .018), 8.98 {+-} 14.58 vs. 2.56 {+-} 5.70 (p = .016), and 10.32 {+-} 15.47 vs. 3.55 {+-} 6.16 (p = .014), respectively. The mean MRSI-based TV for Stage T2b or greater and Stage T2a or less tumors was significantly different (2.23 {+-} 2.62 cm{sup 3} vs. 1.26 {+-} 2.06 cm{sup 3}, respectively; p = .030). This TV correlated with increased prostate-specific antigen levels (odds ratio, 1.293; p = .012). Patients with high-risk PCa had a larger TV than did the patients with intermediate-risk PCa. A similar result was found for the intermediate-risk group compared with the low-risk group (odds ratio, 1.225; p = .041). Conclusion: Biomarkers expressing the relative choline content and TV were significant parameters for the localization of PCa and could be helpful for determining the prognosis more accurately.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bucking Coil Implementation on PMT for Active Cancelling of Magnetic Field

Aerogel and water Cerenkov detectors were employed to tag kaons for a lambda hypernuclear spectroscopic experiment which used the (e,e'K{sup +}) reaction in experimental Hall C at Jefferson Lab (JLab E05-115). Fringe fields from the kaon spectrometer magnet yielded ~5 Gauss at the photomultiplier tubes (PMT) for these detectors which could not be easily shielded. As this field results in a lowered kaon detection efficiency, we implemented a bucking coil on each photomultiplier tubes to actively cancel this magnetic field, thus maximizing kaon detection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrodynamic behavior of wrapped coil water heater tank

In this work, a numerical investigation using computational fluid dynamics (CFD) has been carried out to analyze the thermal behavior of a water tank integrated to a heat pump water heating system (HPWH). The heat pump condenser is a long coil wrapped around the water tank and insulated from outside from which heat is transferred from the heat pump cycle into the water stored inside the tank. The simulated water tank has a capacity of about 170 L with the charging inlet located at the bottom segment of the tank and the discharging outlet located at the top segment of the tank like commercially available water heaters. The tank was simulated during charging/discharging process with isothermal boundary condition at the tank wall to represent the majority of the process for refrigerant condensation inside the heat pump condenser (excluding superheated and sub-cooled section). Three flow rates were selected to represent low, medium and high flow pattern. Both mean and turbulent flow properties were calculated and analyzed. Heat transfer mechanisms inside the tank are quantified by calculating Richardson and Péclet numbers to show the relative contribution of driving forces. The calculations show that advection is dominant over diffusion. Mixing factor is calculated and presented. It is found that the rate of increase of mixing is nonlinear with the increase in flow rate. Mixing increased by a factor of four when the flow rate increased by a factor of two.

stratification↗

Continuous liquid-phase synthesis of nickel phosphide nanoparticles in a helically coiled tube reactor

The continuous liquid phase synthesis of nickel phosphide (Ni 2 P) nanoparticles was studied in a helically coiled tube (HCT) reactor both in single-phase and two-phase slug flows. The reactants were nickel acetylacetonate and tri-n-octylphosphine (TOP) in a 1-octadecane solvent. For the single-phase mode, various parameters such as reaction temperature, residence time, TOP concentration, and P/Ni ratio were studied. It was found that lower temperatures of 320 and 340 °C resulted in the formation of mixed Ni 12 P 5 and Ni 2 P phases, while a higher temperature of 360 °C gave mostly Ni 2 P, with particle sizes increasing from 28 to 42 nm. Upon varying the contact time between 88 and 340 s at 360 °C, a likely sequence of reaction involved an amorphous phase that was transformed in parallel to Ni, Ni 12 P 5 , and Ni 2 P. When the flow in the HCT was changed to a two-phase slug flow by using N 2 to split the continuous liquid phase into small liquid columns, the product was nearly 100% Ni 2 P and the particle size was as small as 3–4 nm. This was attributed to the enhanced mass transfer in the small liquid columns of the slug flow that led to higher reaction rates. Finally, it is highlighted that the HCT operated in a slug flow is an efficient and continuous method for the fabrication of nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron cyclotron resonance ion sources with arc-shaped coils

The minimum-B magnetic field structure of electron cyclotron resonance ion sources (ECRIS) has conventionally been formed with a combination of solenoids and a hexapole magnet. However, minimum-B structure can also be formed with arc-shaped coils. Recently it was shown that multiply charged heavy-ions can be produced with an ECRIS based on such a structure. In the future, the ARC-ECRIS magnetic field structure can be an interesting option for radioactive ion-beam sources and charge-breeders as well as for high performance ECRIS allowing for 100 GHz plasma heating. This paper presents some design aspects of the ARC-ECRIS.

43 PARTICLE ACCELERATORS↗

Precision HD Polarimetry with the LEGS Crossed-Coil NMR Polarimeter

We have developed a precision NMR polarimeter to observe the proton and deuteron polarization of a frozen spin HD target used in photoproduction experiments at the LEGS facility. This polarimeter uses a pair of magnetically orthogonal (''crossed'') RF coils to reduce the signal to very small levels in the absence of polarization of the sample. This reduces the thermal noise in the total signal with polarization, which improves the statistical precision of the polarization determination. Care has been taken in the design of the instrument to reduce nonthermal sources of noise, with the result that a fractional polarization uncertainty of 4% can be maintained over the lifetime of the targets, which has been as long as 19 months. The non-ideal response of the NMR circuit makes a negligible contribution to this uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗