Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Calorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

CFD Simulations of the AEDC H3 Arc-Jet Flow: Mach 3.3 Nozzle, Flow Surveys, Wedge Models

This paper reports computational simulations and analysis of tests in a high enthalpy arc-jet facility at Arnold Engineering Development Center. These tests were conducted using wedge models placed in a free jet downstream of a 4.5-inch diameter contoured Mach 3.3 nozzle in the H3 facility. For calibration of test conditions, one wedge calibration plate instrumented with an array of pressure and coaxial thermocouple heat flux gages, one stagnation pressure probe and two null-point heat flux calorimeters were used. The pitot pressure and null-point probe measurements give experimental surveys of the test flow, providing assessment of the flow uniformity and valuable data for flow characterization. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle, into the test box and over the wedge models, and comparisons with the experimental measurements. Several issues related to testing are considered: test flow characterization, prediction of surface quantities for three wedge models, effects of model shape change and test article recession, and prediction of surface quantities for the test articles with two circular cavities. These simulations take into account non-uniform total enthalpy profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the wedge model flowfields.

Arc-jet testing↗

Validation of Artemis I Aerothermal Design Models Using Developmental Flight Instrumentation

The inaugural flight of the Space Launch System (SLS) Block 1 launch vehicle, Artemis I, occurred on November 16, 2022, and featured a full suite of Developmental Flight Instrumentation (DFI) that provided aerothermodynamic measurements to assess thermal design and substantiate aerothermodynamic models. The Block 1 launch vehicle aerothermal instrumentation consisted of approximately 277 aerothermal gauges mounted throughout the Orion Multi-Purpose Crew Vehicle (MPCV), Integrated Spacecraft and Payload Element (ISPE), Core Stage (CS) and Solid Rocket Boosters (SRB) and an additional 179 thermal gauges on the Orion Crew Module (CM). Instrumentation included calorimeters, radiometers, pressure transducers, gas temperature probes, and thermocouples. Data was collected from lift-off through CS Main Engine Cut-Off (MECO). The flight data was invaluable for determining aerothermal model performance and developing flight-derived aerothermal environments for flight reconstruction thermal analysis and future SLS aerothermal models. The data offered critical insights into the aerothermodynamic conditions experienced during the launch and ascent of the SLS vehicle. This study compares the flight derived environments to pre-existing design models. The aerothermal models were constructed using MINIVER, the aerothermal engineering code which predicts aerodynamic heating and acts as an integration tool for incorporating databases from computational fluid dynamics (CFD) simulations and wind tunnel test data. The comparisons reveal the fidelity of the design models, highlighting areas where the design models accurately predicted flight conditions and instances where deviations were observed. Preliminary results suggest that while the design models largely aligned with the observed flight data, there were unique observations that reflected needed areas of model refinement. Aerothermal flight data from Artemis I for the SLS Block 1 vehicle will be further utilized to enhance the accuracy of Block 1B and Block 2 aerothermal models, ensuring improved safety and performance for subsequent Artemis missions.

aerothermodynamics↗

Validation of Artemis I Aerothermal Design Models Using Developmental Flight Instrumentation

The inaugural flight of the Space Launch System (SLS) Block 1 launch vehicle, Artemis I, occurred on November 16, 2022, and featured a full suite of Developmental Flight Instrumentation (DFI) that provided aerothermodynamic measurements to assess thermal design and substantiate aerothermodynamic models. The Block 1 launch vehicle aerothermal instrumentation consisted of approximately 277 aerothermal gauges mounted throughout the Orion Multi-Purpose Crew Vehicle (MPCV), Integrated Spacecraft and Payload Element (ISPE), Core Stage (CS) and Solid Rocket Boosters (SRB) and an additional 179 thermal gauges on the Orion Crew Module (CM). Instrumentation included calorimeters, radiometers, pressure transducers, gas temperature probes, and thermocouples. Data was collected from lift-off through CS Main Engine Cut-Off (MECO). The flight data was invaluable for determining aerothermal model performance and developing flight-derived aerothermal environments for flight reconstruction thermal analysis and future SLS aerothermal models. The data offered critical insights into the aerothermodynamic conditions experienced during the launch and ascent of the SLS vehicle. This study compares the flight derived environments to pre-existing design models. The aerothermal models were constructed using MINIVER, the aerothermal engineering code which predicts aerodynamic heating and acts as an integration tool for incorporating databases from computational fluid dynamics (CFD) simulations and wind tunnel test data. The comparisons reveal the fidelity of the design models, highlighting areas where the design models accurately predicted flight conditions and instances where deviations were observed. Preliminary results suggest that while the design models largely aligned with the observed flight data, there were unique observations that reflected needed areas of model refinement. Aerothermal flight data from Artemis I for the SLS Block 1 vehicle will be further utilized to enhance the accuracy of Block 1B and Block 2 aerothermal models, ensuring improved safety and performance for subsequent Artemis missions.

aerothermodynamics↗

Heat Transfer Measurements of NASA Liquid Kerosene/Oxygen Rotating Detonation Rocket Engine

The RDRE has been identified as a viable high performance propulsion system with numerous advantages over the state-of-the-art (SOA) liquid rocket engine. NASA has been investigating this combustion device for applications ranging from lander, upper stage, thruster, and hypersonics. All of the activities funded to date have been focused on closing major technology gaps preventing the RDRE from being used more broadly by industry. One of those gaps include the prediction and management of heat transfer to the walls from the extreme combustion environment. This work overviews the heat transfer measurements made using new and existing hardware. A liquid oxygen / liquid RP-1 RDRE was tested utilizing a calorimeter outer body and outer body nozzle extension. An actively cooled inner body with axial running cooling channels was also used. A bimetallic GRCop-42 / Monel K500 injector was developed and demonstrated to be a viable technology for RDRE environments. Trends in bulk heat loads are discussed along with a direct comparison to constant pressure theory predictions of wall heat transfer. The experimental data obtained in this investigation showed similar heat fluxes to constant pressure theory indicating deflagration may have dominated the flow field. Only a single detonation wave was observed in all tests which imparted a significant dynamic load (vibration) on the test article making measurement of combustor performances extremely challenging. Both accelerometer and load cell data corroborate the extreme G-forces measured. The single wave mode yielded relatively low performances compared with other hot fire test data sets available. This leads to the conclusion that a single detonation wave in this geometry is not sufficient for high performance. Wave multiplicity, or rather, a specific number of waves may yield higher performances.

Thomas Teasley↗

Average Heat Flux Measurements in a Gaseous Detonation-Based Rocket Engine

Rotating detonation rocket engines (RDREs) offer benefits over traditional deflagrative engines, including increased engine performance, compact combustion and negligible detrimental thermoacoustic instabilities due to mode-locking. Realizing the benefits of a detonation-based propulsion system will be accompanied by increased thermal loads due to a combination of heat release at elevated pressure and temperature, as well as compact heat release due to detonation. Managing these heat loads necessitates the development of thermal management strategies. As a first step towards establishing the requirements for detonation-based engine thermal management strategies, this work develops an additively manufactured (AM) water-based, axially resolved calorimeter for integration in an existing 76.8 mm outer diameter (OD) RDRE to measure average chamber heat flux. In particular, the calorimetry outer body provides average heat flux data via circumferential channels at nine axial stations to axially resolve the heat flux distribution on the chamber outer wall. The average heat flux is found to be 5 − 12 MW/m 2 for a straight annulus and 6 − 18 MW/m 2 for a constricted annular configuration which exhibited maximum heat flux at the throat. A difference in heat flux scaling is observed near the detonation region compared to the downstream flow expansion section in the constricted geometry. By quantifying the axial distribution of heat flux, this work seeks to support the development of thermal management systems for long duration firing of detonation-based devices.

Matthew A Maybee↗

Average Heat Flux Measurements in a Gaseous Detonation-Based Rocket Engine

Rotating detonation rocket engines (RDREs) offer benefits over traditional deflagrative engines, including increased engine performance, compact combustion and negligible detrimental thermoacoustic instabilities due to mode-locking. Realizing the benefits of a detonation-based propulsion system will be accompanied by increased thermal loads due to a combination of heat release at elevated pressure and temperature, as well as compact heat release due to detonation. Managing these heat loads necessitates the development of thermal management strategies. As a first step towards establishing the requirements for detonation-based engine thermal management strategies, this work develops an additively manufactured (AM) water-based, axially resolved calorimeter for integration in an existing 76.8 mm outer diameter (OD) RDRE to measure average chamber heat flux. In particular, the calorimetry outer body provides average heat flux data via circumferential channels at nine axial stations to axially resolve the heat flux distribution on the chamber outer wall. The average heat flux is found to be 5 − 12 MW/m 2 for a straight annulus and 6 − 18 MW/m 2 for a constricted annular configuration which exhibited maximum heat flux at the throat. A difference in heat flux scaling is observed near the detonation region compared to the downstream flow expansion section in the constricted geometry. By quantifying the axial distribution of heat flux, this work seeks to support the development of thermal management systems for long duration firing of detonation-based devices.

Matthew A Maybee↗

Thermal Performance of Common Bulk-Fill Cryogenic Insulation Materials in Helium and Hydrogen Background Gases

Maritime shipping of vast quantities of liquid hydrogen (LH 2 ) will be necessary to facilitate a global hydrogen ecosystem; with some studies estimating volumes up to 172,000 m 3 for individual tanker ships, and requiring stationary storage tanks at terminals of 50,000 m 3 to 100,000 m 3 —ten to fifteen times larger than the current largest tank, located at launch pad B at NASA Kennedy Space Center (KSC). Such a radical scale-up will push the boundary of traditional, vacuum-insulated tank designs. Hence, a potential need exists for non-vacuum solutions, which necessitates exploring the thermal performance of insulation materials in non-condensable background gasses at LH 2 temperatures, namely helium and hydrogen. Testing of two bulk-fill insulation materials common to large LH 2 storage tanks, perlite and glass bubbles, in helium and hydrogen was recently conducted by the Cryogenics Test Laboratory at KSC using the Cryostat-100 liquid nitrogen boiloff calorimeter per the ASTM C1774 standard methodology. Effective thermal conductivity (k e ) and heat flux (q) results for each insulation/gas combination are presented across the full vacuum range, as well as thermal profiles through the insulation thickness between 78 K and 293 K.

A M Swanger↗

NASA Space Launch System Artemis I & II Post Flight Ascent Aerothermal Environments Overview

Since 2011 the Aerosciences Branch/EV33 at NASA Marshall Space Flight Center has been involved with the development of ascent external aerothermal environments for the NASA Space Launch System (SLS) Block 1 launch vehicle for the purposes of supporting thermal analysis and the design of thermal protection systems. The SLS Block 1 Artemis I and II launch vehicles successfully launched from Pad39B at NASA Kennedy Space Center on November 16th, 2022 and April 1st, 2026, respectively. Over 70 aerothermal islands, consisting of over 265 operational instruments captured aerodynamic heating and plume induced environments throughout the launch vehicles. Gauges consisted of calorimeters, radiometers, gas temperature probes, pressure transducers, bi-directional pressure probes and thermocouples. Prior to launch, aerothermal design environment models were generated to predict ascent aerodynamic heating and plume induced environments over a design space that covered a range of vehicle trajectories that varied atmospheric, vehicle performance, and off-nominal, engine-out conditions. Post flight reconstruction models were developed for each flight island using the Day-of-Launch (DOL) Best Equivalent Trajectory (BET) that provided freestream conditions and propulsion system boundary conditions. This paper discusses a summary of the ascent aerothermal environments observed during the flights and the respective modelling approaches and the performance of them through comparisons of flight data and predictions.

aerothermodynamics↗

The Astro-H High Resolution Soft X-Ray Spectrometer

We present the overall design and performance of the Astro-H (Hitomi) Soft X-Ray Spectrometer (SXS). The instrument uses a 36-pixel array of x-ray microcalorimeters at the focus of a grazing-incidence x-ray mirror Soft X-Ray Telescope (SXT) for high-resolution spectroscopy of celestial x-ray sources. The instrument was designed to achieve an energy resolution better than 7 eV over the 0.3-12 keV energy range and operate for more than 3 years in orbit. The actual energy resolution of the instrument is 4-5 eV as demonstrated during extensive ground testing prior to launch and in orbit. The measured mass flow rate of the liquid helium cryogen and initial fill level at launch predict a lifetime of more than 4 years assuming steady mechanical cooler performance. Cryogen-free operation was successfully demonstrated prior to launch. The successful operation of the SXS in orbit, including the first observations of the velocity structure of the Perseus cluster of galaxies, demonstrates the viability and power of this technology as a tool for astrophysics.

spectrometers↗

The X-ray Integral Field Unit (X-IFU) for Athena

Athena is designed to implement the Hot and Energetic Universe science theme selected by the European Space Agency for the second large mission of its Cosmic Vision program. The Athena science payload consists of a large aperture high angular resolution X-ray optics (2 m2 at 1 keV) and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager. The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), oering 2.5 eV spectral resolution, with approximately 5" pixels, over a field of view of 5' in diameter. In this paper, we present the X-IFU detector and readout electronics principles, some elements of the current design for the focal plane assembly and the cooling chain. We describe the current performance estimates, in terms of spectral resolution, effective area, particle background rejection and count rate capability. Finally, we emphasize on the technology developments necessary to meet the demanding requirements of the X-IFU, both for the sensor, readout electronics and cooling chain.

X-ray↗

Defining the Operational Envelope for Air Flows in the Miniature Arc-Jet Research Chamber (mARC II)

The second-generation 30 kW miniature Arc-jet Research Chamber (mARC II) at NASA Ames Research Center produces high enthalpy flows relevant for entry systems ground testing. The mARC II facility has recently undergone upgrades, including the installation of a new vacuum system to address the issues preventing it from maintaining underexpanded flow under test conditions. In this work, we present data obtained from an Integrated Systems Testing campaign and provide an initial assessment of arc-jet performance following the upgrades. Air is used as the working gas for the standard mARC II arc-heater configuration with two constrictor disks. Seven runs were investigated for five test conditions to assess the lowest achievable stagnation point heat fluxes for air flow rates of 0.15 or 0.25 g s −1 . The heat flux was measured using a water-cooled Gardon gauge (Ø4.76 mm, 3/16" hemispherical) at 70 mm from the nozzle exit plane. The new vacuum system produced test box pressures in the medium (fine) vacuum range (~0.03 torr, 4 Pa) prior to gas addition and successfully maintained underexpanded flow after gas addition. The upgrade yielded a ~4X reduction in heat flux relative to the previous system for the same set test conditions. We report the lowest heat fluxes measured in mARC II to date, ranging from 26 to 81 W cm −2 , for sonic flow enthalpies of 4–14 MJ kg −1 . Bulk enthalpies estimated using an energy balance method (EB 2 ) are reported for the first time using mARC II.Initial data suggests EB 2 generally estimates lower enthalpies than sonic flow methods for mARC II. Lastly, laminar axisymmetric Navier–Stokes simulations were performed using the NASA DPLR code. Numerical heat flux results show good agreement with experiments at low arc powers (3–15% difference at the minimum set arc current), but discrepancy increases with arc power (49% difference at the maximum set arc current).

Pitot tube↗

Defining the Operational Envelope for Air Flows in the Miniature Arc-Jet Research Chamber (mARC II)

The second-generation 30 kW miniature Arc-jet Research Chamber (mARC II) at NASA Ames Research Center produces high enthalpy flows relevant for entry systems ground testing. The mARC II facility has recently undergone upgrades, including the installation of a new vacuum system to address the issues preventing it from maintaining underexpanded flow under test conditions. In this work, we present data obtained from an Integrated Systems Testing campaign and provide an initial assessment of arc-jet performance following the upgrades. Air is used as the working gas for the standard mARC II arc-heater configuration with two constrictor disks. Seven runs were investigated for five test conditions to assess the lowest achievable stagnation point heat fluxes for air flow rates of 0.15 or 0.25 g s −1 . The heat flux was measured using a water-cooled Gardon gauge (Ø4.76 mm, 3/16" hemispherical) at 70 mm from the nozzle exit plane. The new vacuum system produced test box pressures in the medium (fine) vacuum range (~0.03 torr, 4 Pa) prior to gas addition and successfully maintained underexpanded flow after gas addition. The upgrade yielded a ~4X reduction in heat flux relative to the previous system for the same set test conditions. We report the lowest heat fluxes measured in mARC II to date, ranging from 26 to 81 W cm −2 , for sonic flow enthalpies of 4–14 MJ kg −1 . Bulk enthalpies estimated using an energy balance method (EB 2 ) are reported for the first time using mARC II.Initial data suggests EB 2 generally estimates lower enthalpies than sonic flow methods for mARC II. Lastly, laminar axisymmetric Navier–Stokes simulations were performed using the NASA DPLR code. Numerical heat flux results show good agreement with experiments at low arc powers (3–15% difference at the minimum set arc current), but discrepancy increases with arc power (49% difference at the maximum set arc current).

arc-jet↗

Expanding the Measurement Capabilities of the mARC II Arc-Jet to Map the Operating Envelope for High-Enthalpy Air Flows

The mARC II is a 30 kW arc-jet facility at NASA Ames Research Center developed to produce high-enthalpy flows for low-cost technology development purposes. In this work, we introduce new measurement capabilities following the latest facility upgrades and begin characterizing the operating envelope for the two-disk arc-heater configuration with air as the working gas. The lower bound of the envelope corresponds to the lowest set current and the farthest sensor distance from the nozzle (𝐼set = 40 A, 𝑧 = 69 mm), while the upper bound corresponds to the highest current and closest sensor distance (𝐼set = 200 A, 𝑧 = 2 mm). Stagnation point heat flux was measured using a water-cooled Gardon gauge (⌀4.76 mm, 3/16" hemispherical), with values ranging from 15 ≤ q̇₀ ≤ 900 W/cm2. Stagnation pressure was measured using a water-cooled Pitot probe (⌀4.76 mm, 3/16" hemispherical), with values ranging from 18 ≤ p₀ ≤ 1100 Pa. The upgraded vacuum system is demonstrated to significantly extend the lower end of the operating envelope of the mARC II. Additionally, measurements of bulk enthalpy (3 ≤ h ≤ 13 MJ/kg) and stagnation enthalpy (4 ≤ h₀ ≤ 34 MJ/kg) demonstrate the mARC II facility's high-enthalpy capabilities. Completion of the operating envelope characterization is ongoing in tandem with the development of complementary diagnostic capabilities and numerical simulations.

TPS↗

Expanding the Measurement Capabilities of the mARC II Arc-Jet to Map the Operating Envelope for High-Enthalpy Air Flows

The mARC II is a 30 kW arc-jet facility at NASA Ames Research Center developed to produce high-enthalpy flows for low-cost technology development purposes. In this work, we introduce new measurement capabilities following the latest facility upgrades and begin characterizing the operating envelope for the two-disk arc-heater configuration with air as the working gas. The lower bound of the envelope corresponds to the lowest set current and the farthest sensor distance from the nozzle (𝐼set = 40 A, 𝑧 = 69 mm), while the upper bound corresponds to the highest current and closest sensor distance (𝐼set = 200 A, 𝑧 = 2 mm). Stagnation point heat flux was measured using a water-cooled Gardon gauge (⌀4.76 mm, 3/16" hemispherical), with values ranging from 15 ≤ q̇₀ ≤ 900 W/cm 2 . Stagnation pressure was measured using a water-cooled Pitot probe (⌀4.76 mm, 3/16" hemispherical), with values ranging from 18 ≤ p₀ ≤ 1100 Pa. The upgraded vacuum system is demonstrated to significantly extend the lower end of the operating envelope of the mARC II. Additionally, measurements of bulk enthalpy (3 ≤ h ≤ 13 MJ/kg) and stagnation enthalpy (4 ≤ h₀ ≤ 34 MJ/kg) demonstrate the mARC II facility's high-enthalpy capabilities. Completion of the operating envelope characterization is ongoing in tandem with the development of complementary diagnostic capabilities and numerical simulations.

instrumentation↗

Thermochemically-Closed Sonic-Flow Inversion for Enthalpy and Temperature in Multispecies Arc-Jet Flows

A thermochemically-closed sonic-flow inversion framework (TSIF) is developed to infer bulk enthalpy and total temperature upstream of a choked nozzle in arc-jet flows. The formulation recasts a pressure-rise total enthalpy quantification technique as an inverse problem in characteristic-velocity c * space using measured mass flow rate, upstream total pressure, gas composition, and nozzle throat geometry as inputs. Unlike calorimetric energy-balance approaches or optical diagnostics, the method relies primarily on routinely measured facility quantities combined with explicit thermochemical closure. Thermochemical states are obtained using NASA’s open-source Chemical Equilibrium with Applications (CEA) code, enabling construction of a chemistry-consistent relation between characteristic velocity, total enthalpy, and total temperature under equilibrium or frozen assumptions. A discharge coefficient is self-calibrated using cold-flow (arc-off) operation data and applied to hot-flow (arc-on) measurements, enabling upstream losses to be accounted for without empirical correlations. The framework is applied to air, N 2 , and CO 2 –N 2 arc-jet flows and demonstrates expected trends for the inferred thermochemical states as function of arc power, specific energy input, mass-flow, heater configuration, and test gas. In the air limit, under equilibrium assumptions, the method recovers the classical high-enthalpy asymptotic correlation of Winovich with a mean residual of 4.4%, demonstrating compatibility with established sonic-flow scaling, while extending applicability to arbitrary multi-species mixtures and non-equilibrium chemistry. The framework provides a mixture-flexible methodology for determining bulk thermochemical states in modern arc-jet environments using routine facility pressure, mass-flow, gas-composition, and nozzle-geometry information together with a cold-flow calibration.

stagnation heat flux↗