Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Massive compression for high data rate macromolecular crystallography (HDRMX): impact on diffraction data and subsequent structural analysis

New higher-count-rate, integrating, large-area X-ray detectors with framing rates as high as 17400 images per second are beginning to be available. These will soon be used for specialized macromolecular crystallography experiments but will require optimal lossy compression algorithms to enable systems to keep up with data throughput. Some information may be lost. Can we minimize this loss with acceptable impact on structural information? To explore this question, we have considered several approaches: summing short sequences of images, binning to create the effect of larger pixels, use of JPEG-2000 lossy wavelet-based compression, and use of Hcompress, which is a Haar-wavelet-based lossy compression borrowed from astronomy. We also explore the effect of the combination of summing, binning, and Hcompress or JPEG-2000. In each of these last two methods one can specify approximately how much one wants the result to be compressed from the starting file size. These provide particularly effective lossy compressions that retain essential information for structure solution from Bragg reflections.

47 OTHER INSTRUMENTATION↗

Experimental Determination of the Multiplicity Deadtime Parameter

Definition, extraction, and application of dead-time parameters, in correlated neutron counting, are long standing, thorny issues. Traditionally, dead-time corrections have been estimated on the assumption of a simple paralyzing model, arising from the action of the discriminator in the charged amplifiers connected to the {sup 3}He proportional counters, using a fixed dead-time. Various schemes exist to apply the paralysable model to the multiplicity shift register histogram data. In principle, several methods could be used to estimate the dead-time parameter. The approach which is most widely applied involves measuring a series of Cf-252 sources spanning a wide dynamic range of counting rates. Ratios between the Singles, Doubles and Triples rates which ought to be independent of fissile mass are extracted. The dead-time is chosen so as to achieve the best independence in the ratios, characteristic of the fissioning system, over the counting range. These measurements can be quite laborious to conduct; require a set of Cf-252 sources matched in construction and isotopic composition; require long counts to achieve the requisite precision and involve a good deal of numerical analysis to interpret. In this work we present a simpler scheme which produces comparable values in a way that is easier to implement. In essence we place a near random neutron source, such as may be realized using Am/Li {alpha}-n sources, in the cavity and record the multiplicity histograms as one would for an assay. The variance to mean-squared is narrower than for a random counting experiment, however, as a result of the dead-time losses. A simple formula exists allowing the deadtime to be extracted from this measurement. In this paper, we present results for the traditional approach, the proposed approach and also a variation based on adjusting the total event rate by adding Am/Li sources to a single Cf-252 source fixed in position for the case of a pair of Passive Scrap Multiplicity Counters (PSMC's). Excellent agreement is obtained. Because the variance to mean squared approach gives high precision in a single, short, measurement it lends itself to studying dead-time behaviors systematically as a function of shift register settings, operating voltage and preamplifier trim. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photonic nano-structures on (111)-oriented diamond

We demonstrate the fabrication of single-crystalline diamond nanopillars on a (111)-oriented chemical vapor deposited diamond substrate. This crystal orientation offers optimal coupling of nitrogen-vacancy (NV) center emission to the nanopillar mode and is thus advantageous over previous approaches. We characterize single native NV centers in these nanopillars and find one of the highest reported saturated fluorescence count rates in single crystalline diamond in excess of 10{sup 6} counts per second. We show that our nano-fabrication procedure conserves the preferential alignment as well as the spin coherence of the NVs in our structures. Our results will enable a new generation of highly sensitive probes for NV magnetometry and pave the way toward photonic crystals with optimal orientation of the NV center's emission dipole.

36 MATERIALS SCIENCE↗

Characterization of 244 Cm Neutron Sources

There is a need to find a replacement for the 252 Cf sources currently used in Standards-based performance testing of neutron instrumentation. This is a result of its relatively short half-life, concerns about future availability and recent increases in cost. A potential replacement source, 244 Cm is evaluated in this study where two commercially available sources have been acquired and their neutron emission spectra measured using a pair of spectrometers. Both instruments showed the 244 Cm spontaneous neutron spectrum to be fully consistent with a MCNP6®-calculated spectrum using published Watt fission parameters for 244 Cm. In addition, the emission rate of the weaker 244 Cm source was established through a direct count rate comparison against a calibrated and similarly encapsulated 252 Cf source. The 244 Cm source emission rate was found to be in excellent agreement with value stated on the manufacturer's source certificate. It is concluded that 244 Cm would be an ideal replacement for 252 Cf based on its longer half-life (18.1 y) and its essentially identical neutron emission spectrum. In addition, 244 Cm sources are commercially available at reasonable cost.

244Cm↗

Shielding and Build-up Considerations for Radiation Detection

Abstract -- Shielding for gamma radiation has traditionally focused on the reduction of dose effects. For these applications, reducing the energy of the radiation is important along with reducing the actual number of photons, and therefore large masses of high Z material are typically used. However, for measurements requiring low backgrounds or for detecting low activity signals, such as in homeland security applications, the primary use of shielding is to decrease the total number of background photons (perhaps in a region of interest), and therefore the processes of buildup and down scattering become important. In these applications, where the important measure is count rate instead of dose and low background are important, improved reduction in counts from background radiation may be achieved with specially designed configurations of thin layers of different materials instead of a single thick layer. This paper briefly describes recent modeling and experimental investigations in layered-shielding methodology and provides results with comparison to single shielding material such as Pb. Application of these techniques to some real world problems, such as detector systems for homeland security, is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A matrix-inversion method for gamma-source mapping from gamma-count data

In a previous paper it was proposed that a simple matrix inversion method could be used to extract source distributions from gamma-count maps, using simple models to calculate the response matrix. The method was tested using numerically generated count maps. In the present work a 100 kBq Co{sup 60} source has been placed on a gridded surface and the count rate measured using a NaI scintillation detector. The resulting map of gamma counts was used as input to the matrix inversion procedure and the source position recovered. A multi-source array was simulated by superposition of several single-source count maps and the source distribution was again recovered using matrix inversion. The measurements were performed for several detector heights. The effects of uncertainties in source-detector distances on the matrix inversion method are also examined. The results from this work give confidence in the application of the method to practical applications, such as the segregation of highly active objects amongst fuel-element debris. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Active Interrogation using Photofission Technique for Nuclear Materials Control and Accountability

Innovative systems with increased sensitivity and resolution are in great demand to detect diversion and to prevent misuse in support of nuclear materials management for the U.S. fuel cycle. Nuclear fission is the most important multiplicative process involved in non-destructive active interrogation. This process produces the most easily recognizable signature for nuclear materials. In addition to thermal or high-energy neutrons, high-energy gamma rays can also excite a nucleus and cause fission through a process known as photofission. Electron linear accelerators (linacs) are widely used as the interrogating photon sources for inspection methods involving photofission technique. After photofission reactions, prompt signals are much stronger than the delayed signals, but it is difficult to quantify them in practical measurements. Delayed signals are easily distinguishable from the interrogating radiation. Linac-based, advanced inspection techniques utilizing the delayed signals after photofission have been extensively studied for homeland security applications. Previous research also showed that a unique delayed gamma ray energy spectrum exists for each fissionable isotope. In this work, high-energy delayed γ-rays were demonstrated to be signatures for detection, identification, and quantification of special nuclear materials. Such γ-rays were measured in between linac pulses using independent data acquisition systems. A list-mode system was developed to measure low-energy delayed γ-rays after irradiation. Photofission product yields of 238 U and 239 Pu were determined based on the measured delayed γ-ray spectra. The differential yields of delayed γ-rays were also proven to be able to discriminate nuclear from non-nuclear materials. The measurement outcomes were compared with Monte Carlo simulation results. It was demonstrated that the current available codes have capabilities and limitations in the simulation of photofission process. A two-fold approach was used to address the high-rate challenge in used nuclear fuel assay based on photofission technique. First, a standard HPGe preamplifier was modified to improve its capabilities in high-rate pulsed photofission environment. Second, advanced pulse processing algorithms were shown to greatly improve throughput rate without large sacrifice in energy resolution at ultra-high input count rate. Two customized gamma spectroscopy systems were also developed in real-time on FPGAs. They were shown to have promising performance matching available commercial units.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Periodic X-Ray Emission from the O7 V Star Theta(sup 1) Orionis C

We report the discovery of large-amplitude, periodic X-ray emission from the O7 V star Theta(sup 1) Orionis C, the central star of the Orion Nebula. Ten ROSAT HRI snapshots of the Trapezium cluster taken over the course of 21 days show that the count rate of Theta(sup 1) Ori C varies from 0.26 to 0.41 counts/ s with a clear 15 day period. The soft X-ray variations have the same phase and period as H(alpha) and He II (lambda)4686 variations reported by Stahl et al. and are in antiphase with the C(sub iv) and Si(sub iv) ultraviolet absorption features. We consider five mechanisms which might explain the amplitude, phase, and periodicity of the X-ray variations: (1) colliding-wind emission with an unseen binary companion, (2) coronal emission from an unseen late-type pre-main-sequence star, (3) periodic density fluctuations, (4) absorption of magnetospheric X-rays in a corotating wind, and (5) magnetosphere eclipses. The ROSAT data rule out the first three scenarios but cannot rule out either of the latter two which require the presence of an extended magnetosphere, consistent with the suggestion of Stahl et al. that Theta(sup 1) Ori C is an oblique magnetic rotator. As such, Theta(sup 1) Ori C may be the best example of a high-mass analog to the chemically peculiar, magnetic Bp stars.

Gagne, Marc↗

INL Alpha Radiation Background Study

During a radiological emergency, swift determination of the extent and intensity of the radiological materials that have been released to the environment are important for decision makers to correctly assess the hazards and recommend protective actions. In a radiological emergency, natural background counts need to be subtracted from the total activity for the actual amount of activity present to be assessed. This study provides documented survey results of the soils in and around the INL using instrumentation utilized by field monitoring teams that support the INL. Over three hundred alpha background counts were taken. The average alpha background count rate on portable instruments in use by field monitoring teams is 5 counts per minute and the decision level for activity that should be considered as having activity greater than background is 10 counts per minute. It was also shown that rain or snow can increase the background and its effects are difficult to quantify.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spherical time-encoded radiation imaging simulations

Radiation source localization is important for nuclear nonproliferation and can be obtained using time-encoded imaging systems with unsegmented detectors. A scintillation crystal can be used with a moving coded-aperture mask to vary the detected count rate produced from radiation sources in the far field. The modulation of observed counts over time can be used to reconstruct an image with the known coded-aperture mask pattern. Current time-encoded imaging systems incorporate cylindrical coded-aperture masks and have limits to their fully coded imaging field-of-view. This work focuses on expanding the field-of-view to 4π by using a novel spherical coded-aperture mask. A regular icosahedron is used to approximate a spherical mask. This icosahedron consists of 20 equilateral triangles; the faces of which are each subdivided into four equilateral triangle-shaped voxels which are then projected onto a spherical surface, creating an 80-voxel coded-aperture mask. Furthermore, these polygonal voxels can be made from high-Z materials for gamma-ray modulation and/or low-Z materials for neutron modulation. In this work, we present Monte Carlo N-Particle (MCNP) simulations and simple models programmed in Mathematica to explore image reconstruction capabilities of this 80-voxel coded-aperture mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmic-ray effects on diffuse gamma-ray measurements.

Evaluation of calculations and experimental evidence from 600-MeV proton irradiation indicating that cosmic-ray-induced radioactivity in detectors used to measure the diffuse gamma-ray background produces a significant counting rate in the energy region around 1 MeV. It is concluded that these counts may be responsible for the observed flattening of the diffuse photon spectrum at this energy.

Fishman, G. J.↗

Exosat and IUE observations of SW UMa during superoutburst

IUE and Exosat observations obtained during the March 1986 superoutburst of the SU UMa type dwarf nova SW UMa are presented. The observations show the presence of a hot, extensive, optically thick disk. The UV fluxes show an increase of 1000 over the quiescent values, implying a large increase in mass accretion rate. The Exosat obserations show an increase in the soft X-ray count rate by a factor of 44 over quiescence, while the medium-energy flux remains undetected. The most surprising result is that the softness ratio in superoutburst is similar to the quiescent value of 0.3. No variation at the orbital or spin periods or at the superhump period are evident in the superoutburst X-ray data. A transient variation is observed at 5.1 minutes similar to that observed in the optical a few days after the X-ray observations.

Szkody, Paula↗

Performance of Small Pore Microchannel Plates

Small pore size microchannel plates (MCP's) are needed to satisfy the requirements for future high resolution small and large format detectors for astronomy. MCP's with pore sizes in the range 5 micron to 8 micron are now being manufactured, but they are of limited availability and are of small size. We have obtained sets of Galileo 8 micron and 6.5 micron MCP's, and Philips 6 micron and 7 micron pore MCP's, and compared them to our larger pore MCP Z stacks. We have tested back to back MCP stacks of four of these MCP's and achieved gains greater than 2 x 1O(exp 7) with pulse height distributions of less than 40% FWHM, and background rates of less than 0.3 events sec(exp -1) cm(exp -2). Local counting rates up to approx. 100 events/pore/sec have been attained with little drop of the MCP gain. The bare MCP quantum efficiencies are somewhat lower than those expected, however. Flat field images are characterized by an absence of MCP fixed pattern noise.

Siegmund, O. H. W.↗

Variability of the occurrence frequency of solar flares as a function of peak hard X-ray rate

We study the occurrence frequency of solar flares as a function of the hard X-ray peak count rate, using observations of the Solar Maximum Mission. The size distributions are well represented by power-law distributions with negative indices. As a better alternative to the conventional method, we devise a maximum likelihood method of determining the power-law index of the size distribution. We find that the power-law index of the size distribution changes with time and with the phase of the 154-day periodicity. The size distribution is steeper during the maximum years of solar cycle 21 (1980 and 1981) than during the declining phase (1982-1984). The size distribution, however, is flatter during the maximum phase of the 154-day periodicity than during the minimum phase. The implications of these findings are discussed.

Bai, T.↗

Electrons and cosmic ray produced protons in Saturn's inner magnetosphere

The Cerenkov detector on Pioneer 11 previously observed Crand protons above 600 MeV in Saturn's inner magnetosphere, mixed with a poorly understood background of energetic electrons. The electron count is separated from the proton counts and the first-order angular distributions are established for each species. To do this the theoretical relationships among the harmonic coefficients of the count rate is used as a function of spacecraft roll angle. The majority of the counts were electrons with energy above several MeV; i.e., with drift periods shorter than the satellite orbital resonance. The electrons have isotropic pitch angle distributions, and the protons pancake over most of the region between Mimas and the rings, although there is a small region of dumbbell proton distributions in the vicinity of Janus and epimetheus.

Northrop, T. G.↗

Electrons and Cosmic Ray Produced Protons in Saturn's Inner Magnetosphere

The Cerenkov detector on Pioneer 11 previously observed Crand protons above 600 MeV in Saturn's inner magnetosphere, mixed with a poorly understood background of energetic electrons. The electron count is separated from the proton counts and the first-order angular distributions are established for each species. To do this the theoretical relationships among the harmonic coefficients of the count rate is used as a function of spacecraft roll angle. The majority of the counts were electrons with energy above several MeV; i.e., with drift periods shorter than the satellite orbital resonance. The electrons have isotropic pitch angle distributions, and the protons pancake over most of the region between Nimas and the rings, although there is a small region of dumbbell proton distributions in the vicinity of Janus and Epimetheus.

Northrop, T. G.↗

Electrons and cosmic ray produced protons in Saturn's inner magnetosphere

The Cerenkov detector on Pioneer 11 previously observed Crand protons above 600 MeV in Saturn's inner magnetosphere, mixed with a poorly understood background of energetic electrons. The electron count is separated from the proton counts and the first-order angular distributions are established for each species. To do this the theoretical relationships among the harmonic coefficients of the count rate is used as a function of spacecraft roll angle. The majority of the counts were electrons with energy above several MeV; i.e., with drift periods shorter than the satellite orbital resonance. The electrons have isotropic pitch angle distributions, and the protons pancake over most of the region between Nimas and the rings, although there is a small region of dumbbell proton distributions in the vicinity of Janus and Epimetheus.

Northrop, T. G.↗