Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CORROSION PROTECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Development of Computational Capabilities to Predict the Corrosion Wastage of Boiler Tubes in Advanced Combustion Systems

A comprehensive corrosion research project consisting of pilot-scale combustion testing and long-term laboratory corrosion study has been successfully performed. A pilot-scale combustion facility available at Brigham Young University was selected and modified to enable burning of pulverized coals under the operating conditions typical for advanced coal-fired utility boilers. Eight United States (U.S.) coals were selected for this investigation, with the test conditions for all coals set to have the same heat input to the combustor. In addition, the air/fuel stoichiometric ratio was controlled so that staged combustion was established, with the stoichiometric ratio maintained at 0.85 in the burner zone and 1.15 in the burnout zone. The burner zone represented the lower furnace of utility boilers, while the burnout zone mimicked the upper furnace areas adjacent to the superheaters and reheaters. From this staged combustion, approximately 3% excess oxygen was attained in the combustion gas at the furnace outlet. During each of the pilot-scale combustion tests, extensive online measurements of the flue gas compositions were performed. In addition, deposit samples were collected at the same location for chemical analyses. Such extensive gas and deposit analyses enabled detailed characterization of the actual combustion environments existing at the lower furnace walls under reducing conditions and those adjacent to the superheaters and reheaters under oxidizing conditions in advanced U.S. coal-fired utility boilers. The gas and deposit compositions were then carefully simulated in a series of 1000-hour laboratory corrosion tests, in which the corrosion performances of different commercial candidate alloys and weld overlays were evaluated at various temperatures for advanced boiler systems. Results of this laboratory study led to significant improvement in understanding of the corrosion mechanisms operating on the furnace walls as well as superheaters and reheaters in coal-fired boilers resulting from the coexistence of sulfur and chlorine in the fuel. A new corrosion mechanism, i.e., “Active Sulfidation Corrosion Mechanism,” has been proposed to account for the accelerated corrosion wastage observed on the furnace walls of utility boilers burning coals containing sulfur and chlorine. In addition, a second corrosion mechanism, i.e., “Active Sulfide-to-Oxide Corrosion Mechanism,” has been identified to account for the rapid corrosion attack on superheaters and reheaters. Both of the newly discovered corrosion mechanisms involve the formation of iron chloride (FeCl2) vapor from iron sulfide (FeS) and HCl, followed by the decomposition of FeCl2 via self-sustaining cycling reactions. For higher alloys containing sufficient chromium, the attack on superheaters and reheaters is dominated by Hot Corrosion in the presence of a fused salt. Furthermore, two stages of the hot corrosion mechanism have been identified and characterized in detail. The initiation of hot corrosion attack induced by molten sulfate leads to Stage 1 “acidic” fluxing and re-precipitation of the protective scale formed initially on the deposit-covered alloy surfaces. Once the protective scale is penetrated, Stage 2 Hot Corrosion is initiated, which is dominated by “basic” fluxing and re-precipitation of the scale in the fused salt. Based on the extensive corrosion information generated from this project, corrosion modeling was performed using non-linear regression analysis. As a result of the modeling efforts, two predictive equations have been formulated, one for furnace walls and the other for superheaters and reheaters. These first-of-the-kind equations can be used to estimate the corrosion rates of boiler tubes based on coal chemistry, alloy compositions, and boiler operating conditions for advanced boiler systems.

Coal-Environmental Processes↗

Environmental protection to 922K (1200 F) for titanium alloys

Evaluations are presented of potential coating systems for protection of titanium alloys from hot-salt stress-corrosion up to temperatures of 755 K (900 F) and from oxidation embrittlement up to temperature of 922 K (1200 F). Diffusion type coatings containing Si, Al, Cr, Ni or Fe as single coating elements or in various combinations were evaluated for oxidation protection, hot-salt stress-corrosion (HSSC) resistance, effects on tensile properties, fatigue properties, erosion resistance and ballistic impact resistance on an alpha and beta phase titanium alloy (Ti-6Al-2Sn-4Zr-2Mo). All of the coatings investigated demonstrated excellent oxidation protectiveness, but none of the coatings provided protection from hot-salt stress-corrosion. Experimental results indicated that both the aluminide and silicide types of coatings actually decreased the HSSC resistance of the substrate alloy. The types of coatings which have typically been used for oxidation protection of refractory metals and nickel base superalloys are not suitable for titanium alloys because they increase the susceptibility to hot-salt stress-corrosion, and that entirely new coating concepts must be developed for titanium alloy protection in advanced turbine engines.

Groves, M. T.↗

Environmentally Friendly Corrosion Preventative Compounds for Ground Support Structures

The need to use environmentally friendly technologies throughout future space-related launch programs prompted a study aimed at replacing current petroleum and solvent-based Corrosion Preventive Compounds (CPCs) with environmentally friendly alternatives. The work in this paper focused on the identification and evaluation of environmentally friendly CPCs for use in protecting flight hardware and ground support equipment from atmospheric corrosion. CPCs are used as temporary protective coatings and must survive in the aggressive coastal marine environment that exists throughout the Kennedy Space Center, Florida. The different protection behaviors of fifteen different oily film CPCs, both common petroleum-based and newer environmentally friendly types, were evaluated on various steel and aluminum substrates. CPC and substrate systems were subjected to atmospheric testing at the Kennedy Space Center's Beachside Atmospheric Corrosion Test Site, as well as cyclic accelerated corrosion testing. Each CPC also underwent physical characterization and launch-related compatibility testing. The results for the fifteen CPC systems are presented in this paper.

Montgomery Eliza L.↗

The Behavior of Environmentally Friendly Corrosion Preventative Compounds in an Aggressive Coastal Marine Environment

The shift to use environmentally friendly technologies throughout future space-related launch programs prompted a study aimed at replacing current petroleum and solvent-based Corrosion Preventive Compounds (CPCs) with environmentally friendly alternatives. The work in this paper focused on the identification and evaluation of environmentally friendly CPCs for use in protecting flight hardware and ground support equipment from atmospheric corrosion. The CPCs, while a temporary protective coating, must survive in the aggressive coastal marine environment that exists throughout the Kennedy Space Center, Florida. The different protection behaviors of fifteen different soft film CPCs, both common petroleum-based and newer environmentally friendly types, were evaluated on various steel and aluminum substrates. The CPC and substrate systems were subjected to atmospheric testing at the Kennedy Space Center's Beachside Atmospheric Corrosion Test Site, as well as cyclic accelerated corrosion testing. Each CPC also underwent physical characterization and launch-related compatibility testing . The initial results for the fifteen CPC systems are reported : Key words: corrosion preventive compound, CPC, spaceport, environmentally friendly, atmospheric exposure, marine, carbon steel, aluminum alloy, galvanic corrosion, wire on bolt.

Montgomery, Eliza L.↗

Pre-Demonstration Development of Controlled-Release Corrosion Inhibitors and Healing Agents as Alternatives to Hexavalent Chromium

This Limited Scope Study was directed to achieve the following objectives: (1) Scale-up of materials that can meet MIL-PRF-23377 (solvent-based primer). (2) Provide evidence of resistance to aircraft alkaline cleaners and deicing fluids. (3) Provide formulation for initial ecological and toxicity screening. (4) Submit an interim report that will provide the basis for a future ESTCP demonstration effort. The encapsulation procedure for two corrosion inhibitors was scaled up from lab scale to 2.0 kg. This scale will accommodate high volume production of coatings with encapsulated corrosion inhibitors for large surface areas during a follow on ESTCP demonstration effort. Test results provided evidence of resistance to alkaline cleaners and aircraft deicing fluids and compliance with MIL-PRF-23377. All the MIL-PRF-23377 requirements were met with the exception of the adhesion requirement, in top coated panels, and the flexibility requirement. Work on solving these two problems will be done prior to validation and demonstration of the technology. An initial ecological and toxicity screening identified several factors that were not critical to the acceptance of the encapsulated corrosion inhibitor. This new technology will lead to environmentally friendly alternatives to hexavalent chromium that will enable DoD to protect its assets. Field demonstration, licensing, qualification, and commercialization will allow its real world utilization.

Alternatives to Hexavalent Chromium↗

Status of the DOE/NASA critical gas turbine research and technology project

Activities performed in order to provide an R&T data base for utility gas turbine systems burning coal-derived fuels are described. Experiments were run to determine the corrosivity effects of trace metal contaminants (and potential fuel additives) on gas turbine materials and these results were correlated in a corrosion-life prediction model. Actual fuels were burned in a burner rig hot corrosion test to verify the model. A deposition prediction model was assembled and compared with results of actual coal-derived fuel deposition tests. Thermal barrier coatings were tested to determine their potential for protecting gas turbine hardware from the corrosive contaminants. Several coatings were identified with significantly improved spallation-resistance (and, hence, corrosion resistance).

Clark, J. S.↗

Effect of pH on Corrosion Performance of Cu-Se and Cu-Se-Te Alloys in 3.5% Sodium Chloride Solution

The influence of pH (2, 7, 12) on the corrosion behavior of Cu-Se-Te and Cu-Se alloys in a 3.5% sodium chloride solution was investigated using static immersion testing and electrochemical methods. The morphologies of the alloys after corrosion were observed by scanning electron microscopy. The distribution of elements was detected by energy-dispersive spectrometry, and the phases were identified by x-ray diffraction. The results indicate that the corrosion rate decreases significantly with an increase in pH. No compact protective film forms on the alloy surface when pH is 2; meanwhile, Cu{sub 2}(OH){sub 3}Cl and Cu{sub 2}O films form on the alloy surface when pH is 7 or 12. The corrosion rates of alloys in the NaCl solution with different pH levels vary because the cathode reaction and the protective films affect the corrosion rate synthetically. In addition, the Cu-0.5Se alloy generally exhibits satisfactory conductivity, strength, and corrosion resistance. The corrosion resistance of the Cu-0.5Se alloy is higher than that of the Cu-Se-Te alloys, particularly at low pH levels.

36 MATERIALS SCIENCE↗

Near-Field Corrosion Interactions between Glass and Corrosion Resistant Alloys

This study explores the corrosion interactions between model nuclear waste glass materials and corrosion resistant alloys, under conditions that simulate the near field of a nuclear waste repository. The interactions between the corrosion of stainless steel (SS) 316, alloy G30, or alloy 625, and international simple glass or soda-lime silica glass are systematically studied. The dissimilar materials were exposed in close proximity to each other in different electrolytes at 90 oC. After exposure, the glass surface exposed near metals showed different regimes of corrosion, with distinct surface morphologies and chemistries that were likely affected by the local environment created by the localized corrosion of metals. Surface and solution analyses showed that the corrosion rate of glass was enhanced by the presence of metals. Infrared spectroscopy data suggested the local build-up of stresses in the contact area of glass, which may lead to the mechanical instability of the glass alteration layer. On the other hand, the effect of glass on metal corrosion is strongly dependent on the leaching solution. In electrolytes containing abundant aggressive anions such as Cl-, glass seems to suppress the localized corrosion of SS by the precipitation of a Si-rich surface film that protects the SS substrate from solutions. However, in less aggressive electrolytes, the corrosion rate of SS was increased by the presence of glass corrosion products. Overall, our study showed that the hidden and localized damage on glass in contact with metals may enhance the release of incorporated radionuclides compared to typical uniform glass corrosion. Therefore, more attention should be paid to the corrosion interactions between metals and glass under repository conditions.

Guo, Xiaolei↗

Characterization of passive oxide film on a Ti-5%Ta-1.8%Nb alloy on exposure to severe oxidizing conditions

This paper presents the results of a study on the characteristics of the passive oxide film that forms on the surface of an {alpha} + {beta} Ti-5%Ta-1.8%Nb alloy, which possesses good corrosion resistance in severe oxidizing environment of boiling 11.5 M nitric acid. Through systematic structure-property studies, the microstructure with low corrosion rate (< 1 mpy) in liquid, vapor and condensate phases of nitric acid was identified. The characteristics of the passive film, which imparts corrosion resistance to the alloy, are influenced by its microstructure, temperature and concentration of the acid. The microstructure, thickness and composition of the oxide film were characterized using different techniques. TiO{sub 2}, Nb{sub 2}O{sub 5} and Ta{sub 2}O{sub 5} formed on exposure to vapor and condensate phases, while TiO{sub 2} was observed on exposure to the liquid phase. Detailed microstructural studies showed that the passive film consists of nano-crystalline phases of titanium and tantalum oxides, predominantly anatase in an amorphous matrix. Based on these studies, the mechanism of corrosion of the alloy is derived. - Research Highlights: {yields}Liquid phase corrosion results in a thicker and protective oxide film. {yields}Oxide film is a mixture of amorphous and nano-crystalline anatase. {yields}Higher amounts of Nb{sub 2}O{sub 5} and Ta{sub 2}O{sub 5} form on vapor and condensate phase corrosion. {yields}High corrosion rate in condensate phase is due to selective dissolution of Ti in {alpha} phase.

36 MATERIALS SCIENCE↗

Effectiveness of Vapor Corrosion Inhibitors Under Elevated Chloride Conditions for Aboveground Storage Tank Application

The sand quality used to construct the tank pad is an important contributing factor to the rate of corrosion that occurs on the soil-side of the aboveground storage tanks (ASTs) floor plates. Clean sand that meets specific criteria provides the first line of defense for mitigation of tank floor corrosion. However, it has been observed that the sand quality used for some existing tanks differ greatly from the specifications provided in the API 651 standard; this could be partially due to initial sand quality not meeting the specification, and partially due to the environmental effects over time. For example, rain-water intrusion could lead to higher than the specified contents of corrosive species such as chloride. Tank operators are increasingly using vapor corrosion inhibitors (VCIs) either as a stand alone or in combination with cathodic protection (CP) for ASTs to mitigate soil-side corrosion. VCIs are delivered either through-thefloor or injected through the ports in the ring wall. Experimental studies were conducted to evaluate VCIs’ performance at elevated chloride concentrations and to study the effectiveness of the delivery methods under extreme chloride conditions. The experimental work found that VCI performance is robust and not compromised due to high chloride levels, such as 300 ppm or more. The work also showed that the through-the-floor VCI delivery method is more beneficial compared to the through-the-sand-pad method when tank pad corrosivity is elevated.

Shukla, Pavan K.↗

Corrosion Characteristics of New Superalloy Under Industrial Environmental Conditions

Corrosion behavior of new superalloy was studied in industrial environment at different temperatures by using various selected electrochemical techniques. The results revealed that the alloy is able to form protective oxide scale on its surface at higher temperatures and consequently the corrosion rate is low. The new alloy is found to degrade due to pitting corrosion at 40 and 50 °C and general corrosion at 25 °C. The scanning electron microscope results confirmed the electrochemical results. The energy-dispersive spectroscopy results confirmed the presence of oxides of nickel and alloying elements present in the superalloy. Based on the results obtained with different techniques, the alloy is recommended to fabricate different components for industrial applications with suitable protective coatings.

36 MATERIALS SCIENCE↗

Grease Inhibits Stress-Corrosion Cracking In Bearing Race

Coating with suitable grease found to inhibit stress-corrosion cracking in bore of inner race of ball-bearing assembly operating in liquid oxygen. Protects bore and its corner radii from corrosion-initiating and -accelerating substances like moisture and contaminants, which enter during assembly. Operating life extended at low cost, and involves very little extra assembly time.

Beatty, Robert F.↗

Influence of Temperature on CaO-MgO-Al2O3-SiO2 (CMAS) Corrosion on Thermal Barrier Coatings

Higher operating temperature improves the energy efficiency in gas turbine engines and thermal barrier coatings are applied to protect the blades from high temperature and dust corrosion. Dust composed by CaO-MgO-Al2O3-SiO2 (CMAS) can melt and react with pyrochlore zirconates thermal barrier materials and degrade the performance or cause failure of the coatings. This paper discusses the relationship of the reaction product and corrosion temperature.

20 FOSSIL-FUELED POWER PLANTS↗

Chromizing of 3Cr Steel

Grade 315 steel (Fe-2.9 Cr-1.7 W-0.7 Mo-0.3 Mn-0.3 Si-0.2 V-0.1 Ni-0.13 C-0.01 N) was chromized by the halide-activated pack cementation (HAPC) process. Key process parameters, i.e., coating temperatures and pack compositions, were investigated. Ammonium chloride-activated packs in the 700-1000 C range produced coatings nominally in the 1-8 {micro}m range, as determined by optical and scanning electron microscopy (SEM). Coatings applied in the 900-1000 C temperature range resulted in Cr-rich coatings. The predominant phase in the coating was identified as Cr23C6 by X-ray diffraction. In addition, the presence of chromium nitride, Cr2N, was observed in the coating. The power generation industry is faced with an ever-increasing demand for energy while simultaneously having to reduce carbon emissions. These goals can be facilitated by increasing plant efficiency through the use of higher operating temperatures and pressures. Traditional construction materials, e.g., the ferritic Grade 22 high strength low alloy steel, are limited to operations below {approx} 550 C. Therefore, new materials are required for future plants designed to operate up to 650 C and possibly higher. These new materials need to have improved tensile strength, ductility, toughness, corrosion resistance, and creep properties at elevated temperatures. Oak Ridge National Laboratory (ORNL) is investigating the oxidation and creep behavior of various coatings on Grade 315 steel (Fe-2.9 Cr-1.7 W-0.7 Mo-0.3 Mn-0.3 Si-0.2 V-0.1 Ni-0.13 C-0.01 N), a super-bainitic steel developed for superior creep properties. Thin, chemical vapor-deposited (CVD) aluminide coatings were used to compensate for the reduced corrosion and oxidation resistance that resulted from the low chromium content of the alloy. However, the aluminized Grade 315 alloys performed less-than-favorably under conditions relevant to fossil boilers, leading to the conclusion that higher chromium contents are required for the formation of corrosion-resistant oxide scales in these environments. The halide activated pack cementation (HAPC) process offers a promising low-cost and versatile alternative to CVD as a means of improving corrosion resistance via formation of a protective Cr-containing coating.

36 MATERIALS SCIENCE↗

Allotropic control: How certain fluorinated carbonate electrolytes protect aluminum current collectors by promoting the formation of insoluble coordination polymers

Here, there is a strong incentive for increasing the operation voltage of Li-ion cells above 4.5 V in order to increase the density of stored energy. Aluminum is an inexpensive, lightweight metal that is commonly used as a positive electrode current collector in these cells. Imide LiX salts, such as lithium bis(trifluoromethylsulfonyl)imide (X = TFSI), and lithium bis(fluorosulfonyl)imide (X = FSI), are chemically stable on the energized lithiated transition metal oxide electrodes, but their presence in the electrolyte causes rapid anodic dissolution and pitting of Al current collectors at potentials exceeding 4.0 V versus Li/Li + . For LiBF 4 and LiPF 6 , the release of HF near the energized surfaces passivates the exposed Al metal, inhibiting this pitting corrosion, but it also causes the gradual degradation of the cathode active material, negating this important advantage. Here we report that in certain electrolytes containing fluorinated carbonate solvents and LiX salts, the threshold voltage for safe operation of Al current collectors can be increased to 5.5 V versus Li/Li + . Interestingly, the most efficient solvent also facilitates the formation of an insoluble gel when AlX 3 is introduced into this solvent. We suggest that this solvent promotes the aggregation of coordination polymers of AlX 3 at the exposed Al surface that isolate this surface from the electrolyte, thereby preventing further Al dissolution and corrosion. Other examples of Al collector protection may also involve this mechanism. Our study suggests that such “allotropic control” could be a way of widening the operation window of Li-ion cells without electrode deterioration, Al current collector corrosion, and electrolyte breakdown.

36 MATERIALS SCIENCE↗

Effect of surface nanostructuring on corrosion behavior of Ti–6Al–4V alloy

Surface nanostructure was induced in Ti–6Al–4V alloy by ultrasonic shot peening (USSP) for different durations, from 15 s to 30 min, and the modified surface was characterized by optical, scanning, atomic force and transmission electron microscopy. Nano size grains were observed to form on surface of the USSPed samples and surface roughness was increased with duration of USSP. Polarization study was carried out in Ringer's solution to examine the effect of surface nanostructuring on corrosion resistance of this alloy. Electrochemical corrosion was carried out for all the USSPed specimens as well as the non-USSPed sample in Ringer's solution. Surface morphology of the corroded samples was examined by SEM. In general, corrosion resistance was improved by USSP up to the duration of 15 min and there was maximum improvement in the specimen USSPed for 1 min. However, corrosion resistance was drastically reduced due to USSP for long duration of 30 min. - Highlights: •Nanostructure was induced by USSP on alloy Ti–6Al–4V of about 28 nm. •Grain refinement was confirmed by XRD and TEM. •USSP is an effective technique for the improvement in corrosion resistance. •Nanostructured surface promotes formation of protective surface layer of TiO{sub 2}.

36 MATERIALS SCIENCE↗

Corrosion resistance of alumina forming alloys against molten chlorides for energy production. II: Electrochemical impedance spectroscopy under thermal cycling conditions

Next-generation power systems require higher temperatures to increase the efficiency of electricity production in the power block. Concentrating solar power (CSP) technology is looking for high temperature thermal fluids able to work in the range of 550–750 °C. Molten chlorides containing NaCl, KCl, MgCl 2 , and/or ZnCl 2 are being considered for solar receivers and/or sensible- or latent- thermal energy storage systems. Vapor pressures of chlorides are high enough that in combination with oxygen gaseous compounds will produce a harsh atmosphere that is generally very aggressive to common chromia forming alloys. Corrosion mitigations must consider a solution in which both zones (immersed in fluid and exposed to vapor phase) will be protected. This could easily be obtained using alloy surface modification approaches. Surface passivation, produced after pre-oxidation treatments, of alumina forming alloys (Inconel 702, Haynes 224 and Kanthal APMT) was evaluated in molten 35.59 wt% MgCl2 – 64.41 wt% KCl thermally cycled from 550 °C to 700 °C in flowing Ar and static zero air (ZA) atmospheres. Electrochemical impedance spectroscopy tests and metallographic characterization showed that the best performing alloy was pre-oxidized In702 in ZA at 1050 °C for 4 h due to the formation of protective, dense and continuous alumina layers. The alumina layers were unstable when flowing Ar was used as the inert atmosphere during corrosion evaluations. Corrosion results in static ZA are promising for next-generation CSP applications using molten chlorides because alumina scales were stable after 185 h of immersion in the oxygen-containing atmosphere. Alumina layers in pre-oxidized Al-FA In702 grew from 5 µm (before immersion) to 13 µm (after 185 h of immersion). As a result, the use of these alloys could be commercial feasibility and cost-effective because of the possibility of using oxygen-containing atmospheres instead of keeping enclosed systems with inert atmospheres to protect alloys from corrosion in molten chlorides.

14 SOLAR ENERGY↗