Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Contaminant Removal from Oxygen Production Systems for In Situ Resource Utilization

The In Situ Resource Utilization (ISRU) project has been developing technologies to produce oxygen from lunar regolith to provide consumables to a lunar outpost. The processes developed reduce metal oxides in the regolith to produce water, which is then electrolyzed to produce oxygen. Hydrochloic and hydrofluoric acids are byproducts of the reduction processes, as halide minerals are also reduced at oxide reduction conditions. Because of the stringent water quality requirements for electrolysis, there is a need for a contaminant removal process. The Contaminant Removal from Oxygen Production Systems (CROPS) team has been developing a separation process to remove these contaminants in the gas and liquid phase that eliminates the need for consumables. CROPS has been using Nafion, a highly water selective polymeric proton exchange membrane, to recover pure water from the contaminated solution. Membrane thickness, product stream flow rate, and acid solution temperature and concentration were varied with the goal of maximizing water permeation and acid rejection. The results show that water permeation increases with increasing solution temperature and product stream flow rate, while acid rejection increases with decreasing solution temperature and concentration. Thinner membranes allowed for higher water flux and acid rejection than thicker ones. These results were used in the development of the hardware built for the most recent Mars ISRU demonstration project.

Anthony, Stephen M.↗

On Hilbert-Huang Transform Based Synthesis of a Signal Contaminated by Radio Frequency Interference or Fringes

Norden E. Huang et al. had proposed and published the Hilbert-Huang Transform (HHT) concept correspondently in 1996, 1998. The HHT is a novel method for adaptive spectral analysis of non-linear and non-stationary signals. The HHT comprises two components: - the Huang Empirical Mode Decomposition (EMD), resulting in an adaptive data-derived basis of Intrinsic Mode functions (IMFs), and the Hilbert Spectral Analysis (HSA1) based on the Hilbert Transform for 1-dimension (1D) applied to the EMD IMF's outcome. Although paper describes the HHT concept in great depth, it does not contain all needed methodology to implement the HHT computer code. In 2004, Semion Kizhner and Karin Blank implemented the reference digital HHT real-time data processing system for 1D (HHT-DPS Version 1.4). The case for 2-Dimension (2D) (HHT2) proved to be difficult due to the computational complexity of EMD for 2D (EMD2) and absence of a suitable Hilbert Transform for 2D spectral analysis (HSA2). The real-time EMD2 and HSA2 comprise the real-time HHT2. Kizhner completed the real-time EMD2 and the HSA2 reference digital implementations respectively in 2013 & 2014. Still, the HHT2 outcome synthesis remains an active research area. This paper presents the initial concepts and preliminary results of HHT2-based synthesis and its application to processing of signals contaminated by Radio-Frequency Interference (RFI), as well as optical systems' fringe detection and mitigation at design stage. The Soil Moisture Active Passive (SMAP mission (SMAP) carries a radiometer instrument that measures Earth soil moisture at L1 frequency (1.4 GHz polarimetric - H, V, 3rd and 4th Stokes parameters). There is abundant RFI at L1 and because soil moisture is a strategic parameter, it is important to be able to recover the RFI-contaminated measurement samples (15% of telemetry). State-of-the-art only allows RFI detection and removes RFI-contaminated measurements. The HHT-based analysis and synthesis facilitates recovery of measurements contaminated by all kinds of RFI, including jamming [7-8]. The fringes are inherent in optical systems and multi-layer complex contour expensive coatings are employed to remove the unwanted fringes. HHT2-based analysis allows test image decomposition to analyze and detect fringes, and HHT2-based synthesis of useful image.

Spacecraft Electronics Equipment↗

Modeling Contamination Migration on the Chandra X-Ray Observatory - III

During its first 16 years of operation, the cold (about -60 C) optical blocking filter of the Advanced CCD Imaging Spectrometer (ACIS), aboard the Chandra X-ray Observatory, has accumulated a growing layer of molecular contamination that attenuates low-energy x rays. Over the past few years, the accumulation rate, spatial distribution, and composition have changed. This evolution has motivated further analysis of contamination migration within and near the ACIS cavity, in part to evaluate potential bake-out scenarios intended to reduce the level of contamination. Keywords: X-ray astronomy, CCDs, contamination, modeling and simulation, spacecraft operations

astrophysics↗

Requirements and Sizing Investigation for the Constellation Space Suit Portable Life Support System Trace Contaminant Control

This presentation summarized the results of a trade study that evaluated whether trace contaminant control within the Constellation Spacesuit PLSS could be achieved without a Trace Contaminant Control System (TCCS) by relying on suit leakage, ullage loss from the carbon dioxide and humidity control system, and other factors. Mallory Jennings and Dr. Glenn Waguespack studied trace contaminant generation rates to verify that values reflected the latest designs for Constellation spacesuit system pressure garment materials and PLSS hardware. They also calculated TCCS sizing and conducted a literature survey to review the latest developments in trace contaminant technologies.

Jennings, Mallory A.↗

The Fate of Trace Contaminants in a Crewed Spacecraft Cabin Environment

Trace chemical contaminants produced via equipment offgassing, human metabolic sources, and vehicle operations are removed from the cabin atmosphere by active contamination control equipment and incidental removal by other air quality control equipment. The fate of representative trace contaminants commonly observed in spacecraft cabin atmospheres is explored. Removal mechanisms are described and predictive mass balance techniques are reviewed. Results from the predictive techniques are compared to cabin air quality analysis results. Considerations are discussed for an integrated trace contaminant control architecture suitable for long duration crewed space exploration missions.

Perry, Jay L.↗

Contamination and Surface Preparation Effects on Composite Bonding

Results presented here demonstrate the effect of several prebond surface contaminants (hydrocarbon, machining fluid, latex, silicone, peel ply residue, release film) on bond quality, as measured by fracture toughness and failure modes of carbon fiber reinforced epoxy substrates bonded in secondary and co-bond configurations with paste and film adhesives. Additionally, the capability of various prebond surface property measurement tools to detect contaminants and potentially predict subsequent bond performance of three different adhesives is also shown. Surface measurement methods included water contact angle, Dyne solution wettability, optically stimulated electron emission spectroscopy, surface free energy, inverse gas chromatography, and Fourier transform infrared spectroscopy with chemometrics analysis. Information will also be provided on the effectiveness of mechanical and energetic surface treatments to recover a bondable surface after contamination. The benefits and drawbacks of the various surface analysis tools to detect contaminants and evaluate prebond surfaces after surface treatment were assessed as well as their ability to correlate to bond performance. Surface analysis tools were also evaluated for their potential use as in-line quality control of adhesive bonding parameters in the manufacturing environment.

Kutscha, Eileen O.↗

Air Contamination Quantification by FTIR with Gas Cell

Air quality is of utmost importance in environmental studies and has many industrial applications such as aviators grade breathing oxygen (ABO) for pilots and breathing air for fire fighters. Contamination is a major concern for these industries as identified in MIL-PRF-27210, CGA G-4.3, CGA G-7.1, and NFPA 1989. Fourier Transform Infrared Spectroscopy (FTIR) is a powerful tool that when combined with a gas cell has tremendous potential for gas contamination analysis. Current procedures focus mostly on GC-MS for contamination quantification. Introduction of this topic will be done through a comparison of the currently used deterministic methods for gas contamination with those of FTIR gas analysis. Certification of the mentioned standards through the ISOIEC 17065 certifying body A2LA will be addressed followed by an evaluation of quality information such as the determinations of linearity and the limits of detection and quantitation. Major interferences and issues arising from the use of the FTIR for accredited work with ABO and breathing air will be covered.

Freischlag, Jason↗

Modeling Contamination Migration on the Chandra X-Ray Observatory - IV

During its first 18 years of operation, the cold (about -60degC) optical blocking filters of the Advanced CCD Imaging Spectrometer (ACIS), aboard the Chandra X-ray Observatory, has accumulated a growing layer of molecular contamination, which attenuates low-energy x rays. Over the past several years, the accumulation rate, spatial distribution, and composition have changed. This evolution has motivated further analysis of contamination migration within and near the ACIS cavity, in part to evaluate potential bake-out scenarios intended to reduce the level of contamination. This paper, the fourth on this topic, reports the results of recent contamination-migration simulations and their relevance to a decision whether to bake-out the ACIS instrument.

X-ray astronomy CCDs↗

A Review of LIBS for Real-Time Detection of Trace Silicone Contaminants on CFRP Surfaces

Laser ablation is the removal of material by laser pulses through photochemical, photothermal, or photophysical mechanisms, which is useful to prepare an adherend surface for adhesive bonding. Laser surface treatment is a method that has been under research for the past decade at NASA Langley Research Center (LaRC) to prepare surfaces for adhesive joining of aerospace composite materials and metallic alloys. Laser ablation of composite materials increases surface area and removes the surface contaminants introduced during material handling and fabrication processes. By adjustment of laser parameters, it is possible to obtain repeatable surface conditions, and superficial contaminants can be selectively and efficiently removed without damaging the underlying carbon fibers or the carbon fiber reinforced polymer (CFRP) substrate. Laser induced breakdown spectroscopy (LIBS) is a surface characterization and inspection technique that can be seamlessly integrated into the laser surface treatment process. At NASA LaRC, a single laser system has been used for both laser surface treatment and LIBS, which enables in-situ monitoring of surface contaminants. This work focuses on the advancements at LaRC using LIBS to detect surface silicone contaminants on aerospace CFRP materials and to provide surface quality control in adhesive bonding.

Rodolfo I Ledesma↗

A Review of LIBS for Real-Time Detection of Trace Silicone Contaminants on CFRP Surfaces

Laser ablation is the removal of material by laser pulses through photochemical, photothermal, or photophysical mechanisms, which is useful to prepare an adherend surface for adhesive bonding. Laser surface treatment is a method that has been under research for the past decade at NASA Langley Research Center (LaRC) to prepare surfaces for adhesive joining of aerospace composite materials and metallic alloys. Laser ablation of composite materials increases surface area and removes the surface contaminants introduced during material handling and fabrication processes. By adjustment of laser parameters, it is possible to obtain repeatable surface conditions, and superficial contaminants can be selectively and efficiently removed without damaging the underlying carbon fibers or the carbon fiber reinforced polymer (CFRP) substrate. Laser induced breakdown spectroscopy (LIBS) is a surface characterization and inspection technique that can be seamlessly integrated into the laser surface treatment process. At NASA LaRC, a single laser system has been used for both laser surface treatment and LIBS, which enables in-situ monitoring of surface contaminants. This work focuses on the advancements at LaRC using LIBS to detect surface silicone contaminants on aerospace CFRP materials and to provide surface quality control in adhesive bonding.

Rodolfo I Ledesma↗

Modelling and Laboratory Testing of Particle Resuspension and Transport for the Assessment of Terrestrial-Borne Biological Contamination of the Samples on the Mars 2020 Mission

The Mars 2020 mission will land a rover on the surface of Mars that will acquire, encapsulate, and cache scientifically selected samples of martian material for possible return to Earth by a future mission. The samples will be individually encapsulated and sealed in sample tubes. Each sample, and therefore each sample tube, must be kept clean of viable organisms with a terrestrial origin, which may adhere to the rover on their own and/or on other non-biological particles. Therefore, contrary to previous missions to the Red Planet, Mars 2020 is subject to new and more stringent biological, organic and inorganic contamination requirements. This paper reports on the analyses and testing performed to assess the various vectors that can lead to the terrestrial-borne contamination of the samples, focusing on those that are predicted to be the larger contributors. Specifically, the contamination of the sample tubes is expected to be very small prior to the commencement of the mission’s science phase since these tubes are protected by so-called Fluid Mechanical Particle Barriers. Once on the surface of Mars however the sample tubes will be removed from their FMPBs and be subject to contamination from the rover. Of specific interest is the vector by which winds dislodge some particles from the surface of the rover and transport them to the surrounding soil. Naturally, such assessments require multi-disciplinary analyses involving at minimum the physics of particle adhesion and resuspension from surfaces, fluid mechanics and aerosols. Here we provide an overview of these models. We also report on particle resuspension experiments we have performed at the Jet Propulsion Laboratory to both guide and validate the aforementioned physics models.

Steltzner, Adam↗

Molecular Identification of Microbial Contaminants

Microorganisms can have significant impacts on the success of NASA’s missions, including the integrity of materials, the reliability of scientific results, and maintenance of crew health. Robust cleaning and sterilization protocols are currently in place in NASA facilities, but agency experts agree that microbial contamination is unavoidable and its impact on NASA’s missions and science must be minimized. Therefore, it is critical to understand: 1) what specific microorganisms are present, 2) how they may impact scientific objectives, and 3) how to select appropriate mitigation strategies. The Marshall Space Flight Center (MSFC) Planetary Protection (PP) microbiology lab historically relied solely upon enumeration of culturable microbial contamination associated with spacecraft materials or cleanrooms. However, this process is time consuming, many microbes cannot be cultured, and very few can be identified with any fidelity using NASA standard microbiological methods. The work described in this white paper includes the establishment of molecular identification capabilities at MSFC, including DNA isolation, amplification, purification, and Sanger sequencing. This capability will not only improve planetary protection efforts at MSFC (i.e. by identifying contaminating microorganisms in cleanrooms or on spacecraft) but also offers a service center-wide for the identification of contaminants that arise in other projects, processing locations, or during set up and roll out of spacecraft. This work also lays the foundation for higher throughput efforts to identify large populations of microbes across the lifetime of a project and serves as the starting point for future work into whole genome sequencing, non-culture based methods, or additional characterization studies. Ultimately, accurate identification informs appropriate mitigation strategies, increasing the chances of success for NASA’s missions and objectives.

C. D. Cassilly↗

Modeling of Multicomponent Trace Contaminant Adsorption on Activated Carbon

Modeling of multicomponent trace contaminant adsorption on activated carbon for spacecraft life support applications presents challenges due to the very low contaminant concentrations in cabin air coupled with very strong adsorption of heavier components such as cyclic polydimethylsiloxanes. Both gas-phase and solid-phase micropore mass transfer resistances can be important, and competitive interactions between adsorbed components can result in behavior such as roll-up where lighter components displaced by heavier components have a higher concentration at the outlet than at the inlet. This paper describes the further development of a dynamic trace contaminant adsorption model based on Ideal Adsorbed Solution Theory (IAST). Alternative 1-dimensional and 2-dimensional versions of the model are described with different mass transfer resistance and driving force assumptions. Optimization of solution methods for speed and stability is also described. Mass balance equations are scaled to provide sensitivity over the wide range of component concentrations in cabin air. Model parameters are estimated from isotherm and breakthrough test data on single adsorbate and binary adsorbate systems. Multicomponent results are compared against predictions of a heritage model used extensively by NASA for trace contaminant control system (TCCS) carbon bed sizing. Finally, efforts to implement the model in a second software platform for wider access are described.

Kevin E Lange↗

Updated Analysis of the Trash Compaction and Processing System: Water Collected from Trash, Evaluation of the Source Contaminant Control System, and Zotek® F30 Foam Processing

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). At NASA Ames Research Center (ARC), there are two test systems: the Heat Melt Compactor (HMC), which compacts the trash into a tile with temperature and pressure, and the Source Contaminant Control System (SCCS), which is the gas management subsystem aimed to reduce contaminants by converting them into carbon dioxide (CO 2 ) and water (H 2 O) vapor. Both the HMC and SCCS serve as test systems that support TCPS development by conducting risk reduction activities associated with an ISS technology demonstration. In this paper, the risk reduction activities discussed are the testing of different trash models for operational scenarios in the HMC, investigating the water extracted from those trash models, and managing the gaseous effluents from the trash via contaminant conversion through the SCCS. The HMC has undergone several tests of different trash models and cases in which a containment bag is used or not. For the first topic, this paper will analyze the water collected and recovered from these tests and analyze the effect of specific trash containment bags. For the second topic, this paper will individually evaluate the carbon bed and catalytic oxidizer (CatOx) to understand what components the carbon bed removes and what contaminants are converted in the CatOx. For the third and final topic, this paper will discuss Zotek® F30 foam processing in the HMC unit and testing verification in correlation to defined TCPS requirements. A foam model was added to reduce the volume of foam that take up space in the ISS. Overall, this paper is a compilation and an updated analysis of tests conducted in the lab-scale TCPS at ARC within the past year.

TCPS↗

System and method for the identification of radiation in contaminated rooms

Devices and methods for the characterization of areas of radiation in contaminated rooms are provided. One such device is a collimator with a collimator shield for reducing noise when measuring radiation. A position determination system is provided that may be used for obtaining position and orientation information of the detector in the contaminated room. A radiation analysis method is included that is capable of determining the amount of radiation intensity present at known locations within the contaminated room. Also, a visual illustration system is provided that may project images onto the physical objects, which may be walls, of the contaminated room in order to identify the location of radioactive materials for decontamination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sampling Tools for Contaminated Hot Cells and Remotely Accessed Tanks

The U.S. Department of Energy (DOE) and the Pacific Northwest National Laboratory in collaboration with the Andronikashvili Institute of Physics in Tbilisi, Georgia have developed and tested technologies which sample contaminated areas inside hot cell facilities. Sampling locations in the facility include drains, ventilation exhaust ducts, sumps and shielded waste tanks. Tool designs for sampling each location include the ability to introduce the tool using existing ports, pass-throughs or inter-cells trolley and operate the tool with the existing remote manipulators. Areas inside the hot cell facility that would likely be contaminated from chemically processing irradiated reactor targets and fuel even after decontamination have been identified as potential sampling locations. Andronikashvili Institute of Physics in Tbilisi, Georgia has access to a reactor, hot cells, glove boxes and storage facilities that have been used to develop and test hot cell sampling technologies. These facilities are uncontaminated with radiological material and provide the ability to test these sampling technologies on representative equipment without contaminating the tools. Prototype tools have been fabricate and tested at these facilities using simulants representative of radiological contamination and waste.

Rostomashvili, Z.↗

Speciation of Mercury and Heavy Metals in Hg-contaminated Soils from Oak Ridge TN - 19426

Mercury is present in various forms in the environments. Mercuric compounds, Hg(II) are found predominant species in soil and water, while elemental mercury, Hg0 is the major species in the atmosphere, and organo-mercury is present mostly in food-chain. The speciation of Hg is important to understand its mobility, bioavailability in soils, sediments and biota and potential toxicity on human and environmental health. A catastrophic Hg spill occurred at the Y-12 National Security Complex (Y-12 Plant) at the Oak Ridge Reservation of the Department of Energy (DOE) in 1960's that contaminated facilities, soil, sediment, surface water, and groundwater within the boundaries of the Y-12 Plant and the downstream environment along the East Fork Poplar Creek (EFPC) at the city of Oak Ridge. It is estimated that 350,000 kg of Hg was released to the environment. The EFPC floodplain soils were reported to contain predominantly cinnabar (HgS) form, but other inorganic and organic Hg species, including Hg0 , HgCl{sub 2}, Hg{sub 2}Cl{sub 2}, HgO and CH{sub 3}Hg{sup +} have been found within the Y-12 Facility boundaries and the 23-km long contaminated EFPC. Over the last 25 years, Hg fluxes from the Y-12 Plant have been reduced by various remediation efforts, nonetheless Hg concentration in water and fish have not declined due to the persistent leaching of Hg from contaminated floodplain soils and sediments. In this work, we performed total elemental analyses and Hg speciation in the floodplain soils and sediments collected along EFPC in Oak Ridge, TN. The objective of the study was to elucidate the distribution of Hg in floodplain soil fractions and the relation with metals including arsenic, copper, zinc and lead. Total elemental; characterization was performed by ICP-MS analysis after with HNO{sub 3} and HF dissolution. Sequential extractions were carried out to extract water-soluble (F1), cation-exchangeable (F2) fractions and those bound to carbonates (F3), reducible oxides (F4) (Mn-oxides), organic matter (F5), amorphous (F6) and crystalline iron oxides (F7) and the residual fraction (F8) containing elemental Hg, non-cinnabar Hg and humic acid-bound Hg. Preliminary studies were conducted with artificially spiked and incubated soils as well as soils contaminated with enriched {sup 200}Hg isotope. The results indicated that Hg is predominantly associated with organic matter, amorphous iron and crystalline oxides and the residual fraction. The total Hg in the first four fractions (F1, F2, F3, and F4) were about 1% of the total Hg, while Hg was found equally bound to organic matter (F5) and crystalline Fe-oxides (F7) that accounted about 20% of total Hg. The Hg associated with amorphous iron oxides (F6) accounted as much as 26% of the total Hg and non-cinnabar Hg accounted about 24% of total Hg (non-cinnabar Hg). The results also indicated positive correlation for As, Cu, Pb and Zn levels with those of Hg. Most As was associated with amorphous Fe-oxides. Cu and Pb were dominant both in organic matter and amorphous oxide fractions. Zn was mostly bound to amorphous Fe-oxide but significant amount of Zn was also found to be associated with organic matter and crystalline Fe-oxides. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Processing Technology for Radioactively Contaminated Water at Chernobyl Nuclear Power Plant - 19656

During the operation of the Chernobyl Nuclear Power Plant, distillation by evaporation was the main method for processing radioactively contaminated water. When the plant was decommissioned, the evaporation facility was mothballed and floor drain treatment was suspended in 2016. At present, the existing tanks with the capacity of 26,000 m{sup 3} are more than 60% full with radioactively contaminated floor drains, which requires alternative processing methods. The current process flow for radioactive waste management at State Specialized Enterprise 'Chernobyl NPP' includes processing of accumulated liquid radioactive wastes at a liquid radioactive wastes processing plant. Under the processing technology, liquid radioactive waste is immobilized at the plant by cementation and the resulting solid radioactive waste is then buried in a near-surface storage. Key factors for the selection of alternative radioactively contaminated water processing methods are the possibility to clear the processed water (no control monitoring), which requires the same degree of processing as for drinking water, and minimization of radioactive waste generation due to the lack of free space for solid waste disposal in the near-surface storage. Floor drains that require processing contain radionuclides such as {sup 137}Cs, {sup 90}Sr, {sup 60}Co and {sup 40}K. The current level of the total beta and gamma activity is about 4*105 Bq/kg. The following criteria are set for the Chernobyl NPP site for water to be disposed to the sewerage system: - Max. 37 Bq/kg for the total beta and gamma containing radionuclide activity; - Max. 0.7 Bq/kg for the total alpha containing radionuclide activity. METOIL produces inorganic sorbents for removing radionuclides from liquids and develops sorbent-based technology for a variety of applications related to liquid radioactive waste processing. In 2017-2018, experts from the Chernobyl NPP and METOIL ran several joint laboratory tests to evaluate the efficiency of inorganic sorbents made by METOIL for processing floor drains at the Chernobyl NPP. The test procedure included treatment of radioactively contaminated water in a two-stage sorption process: static sorption (sorbents are mixed in a liquid) and dynamic sorption (the liquid is filtered through a sorbent column). NIKET and MODIKS sorbents were provided for the tests. The results of the test measurements showed that the total alpha containing radionuclide activity is less than 0.026 Bq/kg and the total beta and gamma containing radionuclide activity is 9.2 Bq/kg. The physical and chemical parameters after processing also met the water disposal criteria. High sorption capacity of the sorbents used for the tests allows processing hundreds of water volumes with just one sorbent volume. At present, preparations are underway for full-scale tests at a pilot plant with a capacity of minimum 10 m{sup 3}/day. At a later stage, spent sorbents may be immobilized by inclusion into the cement matrix, which will substantially reduce the amount of radioactive waste to be buried. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗