Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Engineering a Hyperthermophilic Archaeon for Temperature-Dependent Product Formation

Microorganisms growing near the boiling point have enormous biotechnological potential but only recently have molecular engineering tools become available for them. We have engineered the hyperthermophilic archaeon Pyrococcus furiosus, which grows optimally at 100 degrees C, to switch its end products of fermentation in a temperature-controlled fashion without the need for chemical inducers. The recombinant strain (LAC) expresses a gene (ldh) encoding lactate dehydrogenase from the moderately thermophilic Caldicellulosiruptor bescii (optimal growth temperature [T-opt] of 78 degrees C) controlled by a "cold shock" promoter that is upregulated when cells are transferred from 98 degrees C to 72 degrees C. At 98 degrees C, the LAC strain fermented sugar to produce acetate and hydrogen as end products, and lactate was not detected. When the LAC strain was grown at 72 degrees C, up to 3 mM lactate was produced instead. Expression of a gene from a moderately thermophilic bacterium in a hyperthermophilic archaeon at temperatures at which the hyperthermophile has low metabolic activity provides a new perspective to engineering microorganisms for bioproduct and biofuel formation. IMPORTANCE Extremely thermostable enzymes from microorganisms that grow near or above the boiling point of water are already used in biotechnology. However, the use of hyperthermophilic microorganisms themselves for biotechnological applications has been limited by the lack of their genetic accessibility. Recently, a genetic system for Pyrococcus furiosus, which grows optimally near 100 degrees C, was developed in our laboratory. In this study, we present the first heterologous protein expression system for a microorganism that grows optimally at 100 degrees C, a first step towards the potential expression of genes involved in biomass degradation or biofuel production in hyperthermophiles. Moreover, we developed the first system for specific gene induction in P. furiosus. As the cold shock promoter for protein expression used in this study is activated at suboptimal growth temperatures of P. furiosus, it is a powerful genetic tool for protein expression with minimal interference of the host's metabolism and without the need for chemical inducers.

Basen, M↗

Processing and Pretreatment Effects on Vanadium Transport in Nafion Membranes

Here, this work describes how manufacturing processes and pretreatments affect the proton conductivity and vanadyl permeability of Nafion® and how these properties are altered by running in a cell. Five Nafion membranes were examined: reinforced XL100, dispersion cast NR211 and NR212, and extruded N115 and N117. The membranes were subjected to pretreatments that included annealing at 120°C and immersing in ambient temperature and boiling water and sulfuric acid. Vanadyl permeability varied by ~15X with pretreatment and ~3X with manufacturing process. Variations in ionic conductivity were comparatively modest: ~1.5X with pretreatment and ~1.2X with processing. Differences in permeability can be eliminated by annealing the extruded membranes above their glass-transition temperature or by immersing in boiling sulfuric acid. The differences induced by processing and pretreatments were largely absent from membranes removed from vanadium redox cells subjected to repeated charge/discharge cycles.

36 MATERIALS SCIENCE↗

Steady-State Thermal-Hydraulic Analysis of the LEU-Fueled Dalat Nuclear Research Reactor

This paper presents results of steady-state thermal-hydraulic analysis for the designed working core of the Dalat Nuclear Research Reactor (DNRR) using the PLTEMP/ANL code. The core was designed to be loaded with 92 low-enriched uranium (LEU) VVR-M2 fuel bundles (FBs) and 12 beryllium rods surrounding a neutron trap at the core center, for replacement of the previous core with 104 high-enriched uranium (HEU) VVR-M2 FBs. Before using this code for thermohydraulic analysis of the designed LEU working core, it was validated by comparing calculation results with experimental data collected from the HEU working core of the DNRR. The discrepancy between calculated results and measured data was at the maximum about 0.8°C and 1.5°C of fuel cladding and outlet coolant temperatures, respectively. In the design calculation, thermohydraulic safety was confirmed through evaluation of the fuel cladding and coolant temperatures, as well as of other safety parameters such as Departure from Nucleate Boiling Ratio (DNBR) and Onset of Nucleate Boiling Ratio (ONBR). The calculation results showed that, in normal operation conditions at full nominal thermal power of 500 kW without uncertainty parameters, the maximum fuel cladding temperature of the hottest FB was about 90.4°C, which is lower than its limit value of 103°C, the minimum DNBR was 32.0, which is much higher than the recommended value of 1.5, and the minimum ONBR was 1.43, which is higher than the recommended value of 1.4 for VVR-M2 LEU fuel type. When the global and local hot channel factors were taken into account, the maximum temperature of fuel cladding at the hottest FB was about 98.4 °C, for global only, and 114.3°C, for global together with local hot channel factors. The calculation results confirm the safety operation of the designed LEU core loaded with 92 fresh VVR-M2 FBs.

Nguyen, Kien-Cuong↗

Synthesis and Optical Properties of Sulfide Nanoparticles Prepared in Dimethylsulfoxide

Many methods have been reported for the formation of sulfide nanoparticles by the reaction of metallic salts with sulfide chemical sources in aqueous solutions or organic solvents. Here, we report the formation of sulfide nanoparticles in dimethylsulfoxide (DMSO) by boiling metallic salts without sulfide sources. The sulfide sources are generated from the boiling of DMSO and react with metallic salts to form sulfide nanoparticles. In this method DMSO functions as a solvent and a sulfide source as well as a stabilizer for the formation of the nanoparticles. The recipe is simple and economical making sulfide nanoparticles formed in this way readily available for many potential applications.

Li, Yuebin↗

Microbeam X-Ray Absorption Near-Edge Spectroscopy of Alloying Elements in the Oxide Layers of Irradiated Zircaloy-2

Hydrogen pickup of zirconium-based fuel cladding and structural materials during in-reactor corrosion can degrade fuel components because the ingress of hydrogen can lead to the formation of brittle hydrides. In the boiling water reactor (BWR) environment, Zircaloy-2 fuel cladding and structural components such as water rods and channels can experience accelerated hydrogen pickup, whereas Zircaloy-4 components exposed to similar conditions do not. Because the principal difference between the two alloys is that Zircaloy-2 contains nickel, accelerated hydrogen pickup has been hypothesized to result from the presence of nickel. However, an understanding of the mechanism by which this acceleration occurs is still lacking. We investigated the link between hydrogen pickup and the oxidation behavior of alloying elements when incorporated into the oxide layers formed on zirconium alloys when corroded in the reactor. Synchrotron radiation microbeam X-ray absorption near-edge spectroscopy (XANES) at the Advanced Photon Source was performed on carefully selected BWR-corroded Zircaloy-2 water rods at an assembly-averaged burnup ranging from 32.8 to 74.6 GWd/MTU to determine the oxidation states of alloying elements, such as iron and nickel, within the oxide layers as a function of distance from the oxide-metal interface at high burnup. Samples were chosen for comparison based on having similar oxide thicknesses, processing, elevation, reactors, and fluences but different hydrogen pickup fractions. Examinations of the oxide layers formed on these samples showed that (1) the oxidation states of these alloying elements changed with distance from the oxide-metal interface, (2) these elements exhibited delayed oxidation relative to the host zirconium, and (3) nickel in Zircaloy-2 remained metallic in the oxide layer at a longer distance from the oxide-metal interface than iron. An analysis of these results showed an apparent correlation between the delayed oxidation of nickel and higher hydrogen pickup of Zircaloy-2 at high burnup.

alloying elements↗

Boildown Study on Supernatant Liquid Retrieved from AP-107 in May 2010

A boildown study was completed on a composite prepared from supernatant liquid grab samples retrieved from tank 241-AP-107 in May of 2010. The composite was a clear, yellow liquid containing no visible solids at hot cell ambient temperatures (25-27 °C). The density of the test composite was 1.216 g/mL at 26.8 °C. The boiling temperature curves generated at three reduced pressures—40-, 60-, and 80 Torr— displayed steadily increasing boiling temperatures with increasing volume reduction with no significant discontinuities. Only minimal foaming was observed after the volume reduction proceeded beyond 50 %WVR (percent waste volume reduction).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Brief Review of Past INL Work Assessing Radionuclide Content in TMI-2 Melted Fuel Debris: The Use of 144 Ce as a Surrogate for Pu Accountancy

This report serves as a literature review of prior work performed at Idaho National Laboratory, and its predecessor organizations Idaho National Engineering Laboratory (INEL) and Idaho National Engineering and Environmental Laboratory (INEEL), studying radionuclide partitioning within the melted fuel debris of the reactor of the Three Mile Island 2 (TMI-2) nuclear power plant. The purpose of this review is to document prior published work that provides supporting evidence of the utility of using 144 Ce as a surrogate for plutonium within melted fuel debris. When the TMI-2 accident occurred no quantitative nondestructive analysis (NDA) techniques existed that could assay plutonium in the unconventional wastes from the reactor. However, unpublished work performed at INL by D. W. Akers in the late 1980s through the 1990s demonstrated that passive gamma-ray spectrometry of 144 Ce could potentially be used to develop a semi-quantitative correlation for estimating plutonium content in these materials. The fate and transport of radioisotopes in fuel from different regions of the core, including uranium, fission products, and actinides, appear to be well characterized based on the maximum temperature reached by fuel in different parts of the core and the melting point, boiling point, and volatility of those radioisotopes. Also, the chemical interactions between fuel, fuel cladding, control elements, and core structural components appears to have played a large role in determining when and how fuel relocation occurred in the core; perhaps the most important of these reaction appears to be related to the formation of mixed-material alloys, eutectics, in the fuel cladding. Because of its high melting point, low volatility, and similar chemical behavior to plutonium, the element cerium appears to have behaved similarly to plutonium during the evolution of the TMI-2 accident. Anecdotal evidence extrapolated from open-source literature strengthens this logical feasibility for using cerium, which is rather easy to analyze using passive nondestructive analysis gamma-ray spectrometry, as a surrogate for plutonium in the final analysis of TMI-2 melted fuel debris. The generation of this report is motivated by the need to perform nuclear material accountancy measurements on the melted fuel debris that will be excavated from the damaged nuclear reactors at the Fukushima Daiichi nuclear power plant in Japan, which were destroyed by the Tohoku earthquake and tsunami on March 11, 2011. Lessons may be taken from prior U.S. work related to the study of the TMI-2 core debris to support the development of new assay methods for use at Fukushima Daiichi. While significant differences exist between the two reactor systems (pressurized water reactor (TMI-2) versus boiling water reactor (FD), fresh water post-accident cooing (TMI-2) versus salt water (FD), maintained containment (TMI-2) versus loss of containment (FD)) there remain sufficient similarities to motivate these comparisons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

How many replicate tests do I need?$-$ Variability of cookstove performance and emissions has implications for obtaining useful results

Almost half of the world’s population still cooks on biomass cookstoves of poor efficiency and primitive design, such as three stone fires (TSF). Emissions from biomass cookstoves contribute to adverse health effects and climate change. A number of “improved cookstoves” with higher energy efficiency and lower emissions have been designed and promoted across the world. During the design development, and for selection of a stove for dissemination, the stove performance and emissions are commonly evaluated, communicated and compared using the arithmetic average of replicate tests made using a standardized laboratory-based test, commonly the water boiling test (WBT). However, published literature shows different WBT results reported from different laboratories for the same stove technology. Also, there is no agreement in the literature on how many replicate tests should be performed to ensure “significance” in the reported average performance. This matter has not received attention in the rapidly growing literature on stoves, and yet is crucial for estimating and communicating the performance of a stove, and for comparing the performance between stoves. We present results of statistical analyses using data from a number of replicate tests of performance and emission of the Berkeley-Darfur Stove (BDS) and the TSF under well-controlled laboratory conditions. We observed moderate variability in the test results for the TSF and BDS when measuring several characteristics. Here we focus on two as illustrative: time-to-boil and PM2.5 (particulate matter less than or equal to 2.5 micrometers in diameter) emissions. We demonstrate that interpretation of the results comparing these stoves could be misleading if only a small number of replicates had been conducted. We then describe a practical approach, useful to both stove testers and designers, to assess the number of replicates needed to obtain useful data. Caution should be exercised in attaching high credibility to results based on only a few replicates of cookstove performance and emissions. Stove designers, testers, program implementers and decision makers should all benefit from improved awareness of the importance of adequate number of replicates required to produce practically useful test data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Steady-State Thermal-Hydraulics Feasibility Study for the Conversion of the BR2 Reactor to LEU

As part of the conversion from highly-enriched uranium (HEU) to low-enriched uranium (LEU) fuel, it is necessary to verify that an LEU core can operate safely at the same maximum nominal heat flux. Therefore, the main goal of this chapter is to determine the impact of using LEU fuel on the thermal performance and thermal limits of the BR2 core. More specifically, this chapter will present analyses performed to evaluate the margins to onset of nucleate boiling (ONB), fully developed nucleate boiling (FDNB) and flow instability (FI) at steady-state using the PLTEMP/ANL v4.1 code (referred as PLTEMP from here on). Section 2 describes the basis for the current thermal limits. Section 3 provides a brief description of the BR2 core and fuel assemblies. Section 4 contains a description of the computational methodology used to perform the analysis. Section 5 presents the results while Section 6 summarizes the analysis and presents some conclusions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RELAP-7 Development Updates

RELAP-7 is a nuclear systems safety analysis code being developed at the Idaho National Laboratory, and is the next generation tool in the RELAP reactor safety/systems analysis application series. RELAP-7 development began in 2011 to support the Risk Informed Safety Margins Characterization (RISMC) Pathway of the Light Water Reactor Sustainability (LWRS) program. The overall design goal of RELAP-7 is to take advantage of the previous thirty years of advancements in computer architecture, software design, numerical methods, and physical models in order to provide capabilities needed for the RISMC methodology and to support nuclear power safety analysis. The code is being developed based on Idaho National Laboratory’s modern scientific software development framework – MOOSE (the Multi-Physics Object-Oriented Simulation Environment). The initial development goal of the RELAP-7 approach focused primarily on the development of an implicit algorithm capable of strong (nonlinear) coupling of the dependent hydrodynamic variables contained in the 1-D/2-D flow models with the various 0-D system reactor components that compose various boiling water reactor (BWR) and pressurized water reactor nuclear power plants (NPPs). During Fiscal Year (FY) 2015, the RELAP-7 code has been further improved with expanded capability to support boiling water reactor (BWR) and pressurized water reactor NPPs analysis. The accumulator model has been developed. The code has also been coupled with other MOOSE-based applications such as neutronics code RattleSnake and fuel performance code BISON to perform multiphysics analysis. A major design requirement for the implicit algorithm in RELAP-7 is that it is capable of second-order discretization accuracy in both space and time, which eliminates the traditional first-order approximation errors. The second-order temporal is achieved by a second-order backward temporal difference, and the one-dimensional second-order accurate spatial discretization is achieved with the Galerkin approximation of Lagrange finite elements. During FY-2015, we have done numerical verification work to verify that the RELAP-7 code indeed achieves 2nd-order accuracy in both time and space for single phase models at the system level.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

STAR-CCM+ Verification and Validation Plan

The commercial Computational Fluid Dynamics (CFD) code STAR-CCM+ provides general purpose finite volume method solutions for fluid dynamics and energy transport. This document defines plans for verification and validation (V&V) of the base code and models implemented within the code by the Consortium for Advanced Simulation of Light water reactors (CASL). The software quality assurance activities described herein are port of the overall software life cycle defined in the CASL Software Quality Assurance (SQA) Plan [Sieger, 2015]. STAR-CCM+ serves as the principal foundation for development of an advanced predictive multi-phase boiling simulation capability within CASL. The CASL Thermal Hydraulics Methods (THM) team develops advanced closure models required to describe the subgrid-resolution behavior of secondary fluids or fluid phases in multiphase boiling flows within the Eulerian-Eulerian framework of the code. These include wall heat partitioning models that describe the formation of vapor on the surface and the forces the define bubble/droplet dynamic motion. The CASL models are implemented as user coding or field functions within the general framework of the code. This report defines procedures and requirements for V&V of the multi-phase CFD capability developed by CASL THM. Results of V&V evaluations will be documented in a separate STAR-CCM+ V&V assessment report. This report is expected to be a living document and will be updated as additional validation cases are identified and adopted as part of the CASL THM V&V suite.

97 MATHEMATICS AND COMPUTING↗

CTF Validation and Verification Manual

Coolant-Boiling in Rod Arrays- Two Fluids (COBRA-TF) is a Thermal/Hydraulic (T/H) simulation code designed for Light Water Reactor (LWR) analysis. It uses a two-fluid, three-field (i.e. fluid film, fluid drops, and vapor) modeling approach. Both sub-channel and 3D Cartesian forms of nine conservation equations are available for LWR modeling. The code was originally developed by Pacific Northwest Laboratory in 1980 and has been used and modified by several institutions over the last several decades. COBRA-TF is also used at the Pennsylvania State University (PSU) by the Reactor Dynamics and Fuel Management Group (RDFMG), and has been improved, updated, and subsequently became the PSU RDFMG version of COBRA-TF (CTF). One part of the improvement process includes validating the methods in CTF. This document seeks to provide a certain level of certainty and confidence in the predictive capabilities of the code for the scenarios it was designed to model--rod bundle geometries with operating conditions that are representative of prototypical Pressurized Water Reactor (PWR)s and Boiling Water Reactor (BWR)s in both normal and accident conditions. This is done by modeling a variety of experiments that simulate these scenarios and then presenting a qualitative and quantitative analysis of the results that demonstrates the accuracy to which CTF is capable of capturing specific quantities of interest.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The STAT7 Code for Statistical Propagation of Uncertainties In Steady-State Thermal Hydraulics Analysis of Plate-Fueled Reactors

The STAT code was written to automate many of the steady-state thermal hydraulic safety calculations for the MIT research reactor, both for conversion of the reactor from high enrichment uranium fuel to low enrichment uranium fuel and for future fuel re-loads after the conversion. A Monte-Carlo statistical propagation approach is used to treat uncertainties in important parameters in the analysis. These safety calculations are ultimately intended to protect against high fuel plate temperatures due to critical heat flux or departure from nucleate boiling or onset of flow instability; but additional margin is obtained by basing the limiting safety settings on avoiding onset of nucleate boiling. STAT7 can simultaneously analyze all of the axial nodes of all of the fuel plates and all of the coolant channels for one stripe of a fuel element. The stripes run the length of the fuel, from the bottom to the top. Power splits are calculated for each axial node of each plate to determine how much of the power goes out each face of the plate. By running STAT7 multiple times, full core analysis has been performed by analyzing the margin to ONB for each axial node of each stripe of each plate of each element in the core.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The SAS4A/SASSYS-1 Safety Analysis Code System, Version 5

The SAS4A/SASSYS-1 computer code is developed by Argonne National Laboratory for thermal, hydraulic, and neutronic analysis of power and flow transients in liquidmetal- cooled nuclear reactors (LMRs). SAS4A was developed to analyze severe core disruption accidents with coolant boiling and fuel melting and relocation, initiated by a very low probability coincidence of an accident precursor and failure of one or more safety systems. SASSYS-1, originally developed to address loss-of-decay-heat-removal accidents, has evolved into a tool for margin assessment in design basis accident (DBA) analysis and for consequence assessment in beyond-design-basis accident (BDBA) analysis. SAS4A contains detailed, mechanistic models of transient thermal, hydraulic, neutronic, and mechanical phenomena to describe the response of the reactor core, its coolant, fuel elements, and structural members to accident conditions. The core channel models in SAS4A provide the capability to analyze the initial phase of core disruptive accidents, through coolant heat-up and boiling, fuel element failure, and fuel melting and relocation. Originally developed to analyze oxide fuel clad with stainless steel, the models in SAS4A have been extended and specialized to metallic fuel with advanced alloy cladding. SASSYS-1 provides the capability to perform a detailed thermal/hydraulic simulation of the primary and secondary sodium coolant circuits and the balance-ofplant steam/water circuit. These sodium and steam circuit models include component models for heat exchangers, pumps, valves, turbines, and condensers, and thermal/hydraulic models of pipes and plena. SASSYS-1 also contains a plant protection and control system modeling capability, which provides digital representations of reactor, pump, and valve controllers and their response to input signal changes.

97 MATHEMATICS AND COMPUTING↗

Residual Stresses in SAVY 4000 and Hagan Container Bodies

Chloride-induced stress corrosion cracking (SCC) has been investigated as a potential failure mechanism for the SAVY 4000 and the Hagan containers used to store plutonium-bearing materials at Los Alamos National Laboratory. This report discusses the regions of the container bodies most susceptible to SCC and the magnitude of the residual stresses in those regions. Boiling MgCl2 testing indicated that for both containers the region near the top weld was most susceptible to SCC. The Hagan showed through wall cracking after 22-24 hours of exposure both parallel (axial stresses) and perpendicular (hoop stresses) to the weld. The SAVY 4000 container showed significant cracking above and below the weld after 47 hours of exposure but there was no visual evidence of a through wall crack and the cracks did not leak water. Two through wall holes formed in the bottom of the SAVY 4000 container after 44-46 hours of exposure. For both containers, average “through wall” residual stresses were determined from hole drilling data 4 mm below the weld. In the Hagan body, average tensile hoop stresses were 194 MPa and average compressive axial stresses were -120 MPa. In the SAVY 4000 body, average compressive hoop stresses were 11 MPa and average tensile axial stresses were 25 MPa. Results suggest that because the Hagan container exhibited through wall cracking in a shorter time in boiling MgCl2 and had the higher average tensile stress, 194 MPa hoop stress, it is more susceptible to SCC than the SAVY 4000 container.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Informing hazardous zones for on-board maritime hydrogen liquid and gas systems

The significantly higher buoyancy of hydrogen compared to natural gas means that hazardous zones defined in the IGF code may be inaccurate if applied to hydrogen. This could place undue burden on ship design or could lead to situations that are unknowingly unsafe. We present dispersion analyses to examine three vessel case studies: (1) abnormal external vents of full blowdown of a liquid hydrogen tank due to a failed relief device in still air and with crosswind; (2) vents due to naturally-occurring boil-off of liquid within the tank; and (3) a leak from the pipes leading into the fuel cell room. The size of the hydrogen plumes resulting from a blowdown of the tank depend greatly on the wind conditions. It was also found that for normal operations releasing a small amount of "boil- off" gas to regulate the pressure in the tank does not create flammable concentrations.

08 HYDROGEN↗

CTF 4.0 Validation and Verification

Coolant-Boiling in Rod Arrays- Two Fluids (COBRA-TF) is a Thermal/Hydraulic (T/H) simulation code designed for Light Water Reactor (LWR) analysis. It uses a two-fluid, three-field (i.e. fluid film, fluid drops, and vapor) modeling approach. Both sub-channel and 3D Cartesian forms of nine conservation equations are available for LWR modeling. The code was originally developed by Pacific Northwest Laboratory in 1980 and has been used and modified by several institutions over the last several decades. COBRA-TF is also used at the Pennsylvania State University (PSU) by the Reactor Dynamics and Fuel Modeling Group (RDFMG) and has been improved, updated, and subsequently became the PSU RDFMG version of COBRA-TF (CTF). One part of the improvement process includes validating the methods in CTF. This document seeks to provide a certain level of certainty and confidence in the predictive capabilities of the code for the scenarios it was designed to model—rod bundle geometries with operating conditions that are representative of prototypical Pressurized Water Reactor (PWR)s and Boiling Water Reactor (BWR)s in both normal and accident conditions. This is done by modeling a variety of experiments that simulate these scenarios and then presenting a qualitative and quantitative analysis of the results that demonstrates the accuracy to which CTF is capable of capturing specific quantities of interest.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Investigation of Thermolytic Hydrogen Generation Rate in Tank 28 and Tank 39 Samples

This report contains hydrogen generation rate (HGR) measurements of Tank 28 and Tank 39 radioactive samples with and without added glycolate as a function of temperature. The objective of the Tank 28 and Tank 39 HGR measurements is to extend the knowledge from previous sample thermolysis HGR measurements and augment simulant testing for developing models for the Savannah River Site (SRS) Concentration, Storage, and Transfer Facilities (CSTF) thermolysis HGR with and without added glycolate. Tank 28 testing is applicable to concentrated salt supernate, legacy organic compounds resulting from the F-Canyon processes and boiling in the 3H-Evaporator System. Tank 39 testing is applicable to moderately concentrated salt supernate and organic compounds in fresh waste from the H-Canyon processes. For HGR tests with added sodium glycolate, the glycolate concentrations added to Tank 28 (500 mg/L) and Tank 39 (2000 mg/L) are based on concentrations expected to result in quantifiable HGR between temperatures of 70 °C and the atmospheric pressure boiling point. The added glycolate is much higher than the expected future glycolate concentrations in Tank 28, Tank 39, and similar CSTF tanks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗