Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

A Comprehensive Analysis of the Interphasial and Structural Evolution over Long–Term Cycling of Ultrahigh–Nickel Cathodes in Lithium–Ion Batteries

Ultrahigh-Ni layered oxides hold great promise as high-energy-density cathodes at an affordable cost for lithium-ion batteries, yet their practical application is greatly hampered by the poor cyclability. Herein, by employing LiNi 0.94 Co 0.06 O 2 as a model cathode in a full-cell configuration, the interphasial and structural evolution processes of ultrahigh-Ni layered oxides are systematically investigated over the course of their service life (1500 cycles). By applying advanced analytic techniques (e.g., Li-isotope labeling, region-of-interest method), the dynamic chemical evolution on the cathode surface is revealed with spatial resolution, and the correlation between lattice distortion and cathode surface reactivity is established. Benefiting from in situ X-ray diffraction (XRD) analysis, the ultrahigh-Ni layered oxide is demonstrated to undergo dual-phase reaction mechanisms with huge lattice variation, which leads to a decrease in crystallinity and secondary particle pulverization. Furthermore, the critical impact of cathode surface reaction on the graphite anode–electrolyte interphase (AEI) is revealed at nanometer scale, and a universal chemical/physical evolution process of the AEI is illustrated, for the first time. Finally, the practical viability of ultrahigh-Ni layered oxides is demonstrated through Al-doping strategy. Finally, this work presents a comprehensive understanding of the structural and interphasial degradation of ultrahigh-Ni layered oxide cathodes for developing high-energy-density lithium-ion batteries.

25 ENERGY STORAGE↗

Comparing the Performance of Three Land Models in Global C Cycle Simulations: A Detailed Structural Analysis: Structural Analysis of Land Models

Land models are valuable tools to understand the dynamics of global carbon (C) cycle. Various models have been developed and used for predictions of future C dynamics but uncertainties still exist. Diagnosing the models’ behaviors in terms of structures can help to narrow down the uncertainties in prediction of C dynamics. In this study three widely used land surface models, namely CSIRO’s Atmosphere Biosphere Land Exchange (CABLE) with 9 C pools, Community Land Model (version 3.5) combined with Carnegie-Ames-Stanford Approach (CLM-CASA) with 12 C pools and Community Land Model (version 4) (CLM4) with 26 C pools were driven by the observed meteorological forcing. The simulated C storage and residence time were used for analysis. The C storage and residence time were computed globally for all individual soil and plant pools, as well as net primary productivity (NPP) and its allocation to different plant components’ based on these models. Remotely sensed NPP and statistically derived HWSD, and GLC2000 datasets were used as a reference to evaluate the performance of these models. Results showed that CABLE exhibited better agreement with referenced C storage and residence time for plant and soil pools, as compared with CLM-CASA and CLM4. CABLE had longer bulk residence time for soil C pools and stored more C in roots, whereas, CLM-CASA and CLM4 stored more C in woody pools due to differential NPP allocation. Overall, these results indicate that the differences in C storage and residence times in three models are largely due to the differences in their fundamental structures (number of C pools), NPP allocation and C transfer rates. Our results have implications in model development and provide a general framework to explain the bias/uncertainties in simulation of C storage and residence times from the perspectives of model structures.

54 ENVIRONMENTAL SCIENCES↗

Angular analysis of B$0\atop{d}$ → K*μ + μ - decays in pp collisions at $\sqrt{s}=8$ TeV with the ATLAS detector

An angular analysis of the decay B$0\atop{d}$ → K*μ + μ - is presented, based on proton-proton collision data recorded by the ATLAS experiment at the LHC. The study is using 20.3 fb -1 of integrated luminosity collected during 2012 at centre-of-mass energy of $\sqrt{s}=8 $ TeV. Measurements of the K* longitudinal polarisation fraction and a set of angular parameters obtained for this decay are presented. The results are compatible with the Standard Model predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantitative Real-Time Fluoroscopy Analysis on Measurement of the Hepatic Arterial Flow During Transcatheter Arterial Chemoembolization of Hepatocellular Carcinoma: Comparison with Quantitative Digital Subtraction Angiography Analysis

PurposeTo quantify the arterial flow change during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC) using digital subtraction angiography, quantitative color-coding analysis (d-QCA), and real-time subtraction fluoroscopy QCA (f-QCA).Materials and MethodsThis prospective study enrolled 20 consecutive patients with HCC who had undergone TACE via a subsegmental approach between February 2014 and April 2015. The TACE endpoint was a sluggish antegrade tumor-feeding arterial flow. d-QCA and f-QCA were used for determining the relative maximal density time (rT{sub max}) of the selected arteries. The rT{sub max} of the selected arteries was analyzed in d-QCA and f-QCA before and after TACE, and its correlation in both analyses was evaluated.ResultsThe pre- and post-TACE rT{sub max} of the embolized segmental artery in d-QCA and f-QCA were 1.59 ± 0.81 and 2.97 ± 1.80 s (P < 0.001) and 1.44 ± 0.52 and 2.28 ± 1.02 s (P < 0.01), respectively. The rT{sub max} of the proximal hepatic artery did not significantly change during TACE in d-QCA and f-QCA. The Spearman correlation coefficients of the pre- and post-TACE rT{sub max} of the embolized segmental artery between d-QCA and f-QCA were 0.46 (P < 0.05) and 0.80 (P < 0.001). Radiation doses in one series of d-QCA and f-QCA were 140.7 ± 51.5 milligray (mGy) and 2.5 ± 0.7 mGy, respectively.Conclusionsf-QCA can quantify arterial flow changes with a higher temporal resolution and lower radiation dose. Flow quantification of the embolized segmental artery using f-QCA and d-QCA is highly correlated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On seasonal and semi-annual approach for flood frequency analysis

As a supplementary method to the conventional flood frequency analysis based on annual peak flows, we propose an approach in this paper to infer the flood frequency distribution on quarterly and semi-annual time scale, which are then converted to annual time scale to obtain the floods corresponding to return periods in unit of year. Two criteria for test of data independence, namely, minimum 7 and 15-day interval between two consecutive peak flows, are tested. The proposed approach was applied to Des Moines River at Fort Dodge, Iowa, USA using its 62 years of observation daily flows. The results show that the estimated floods for given return periods from quarter-annual data series are in general higher than the corresponding estimated floods from semi-annual data series, which is further larger than estimated floods from annual peak flows. In conclusion, the floods estimated from semi-annual data series agree well with the results of previous US Geological Survey study.

54 ENVIRONMENTAL SCIENCES↗

Quality assurance of temporal variability of natural decay chain and neutron induced background for low-level NORM analysis

In this study, twenty-one high purity germanium (HPGe) background spectra were collected over 2 years at Los Alamos National Laboratory. A quality assurance methodology was developed to monitor spectral background levels from thermal and fast neutron flux levels and naturally occurring radioactive material decay series radionuclides. 238 U decay products above 222 Rn demonstrated minimal temporal variability beyond that expected from counting statistics. 238 U and 232 Th progeny below Rn gas displayed at most twice the expected variability. Further, an analysis of the 139 keV 74 Ge(n, γ) and 691 keV 72 Ge(n, n') spectral features demonstrated temporal stability for both thermal and fast neutron fluxes.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Noise analysis for the Sorkin and Peres tests performed on a quantum computer

We use quantum computers to test the foundations of quantum mechanics through quantum algorithms that implement some of the experimental tests as the basis of the theory's postulates. These algorithms can be used as a test of the physical theory under the premise of a perfect hardware or as a test of the hardware under the premise that quantum theory is correct. In this paper, we show how the algorithms can be used to test the efficacy of a quantum computer in obeying the postulates of quantum mechanics. We study the effect of different types of errors on the results of experimental tests of the postulates. A salient feature of this error analysis is that it is deeply rooted in the fundamentals of quantum mechanics as it highlights how systematic errors affect the quantumness of the quantum computer.

Sadana, Simanraj↗

Rapid Analysis of Ingredients in Cream Using Ultrasonic Mist–Direct Analysis in Real-Time Time-of-Flight Mass Spectrometry

A novel method for the simultaneous detection of ingredients in pharmaceutical applications such as creams and lotions was developed. An ultrasonic atomizer has been used to produce a mist containing ingredients. The analyte molecules in the mist can be ionized by using direct analysis in real time (DART) at lower temperature than traditionally used, and we thus solved the problem of normal DART-MS measurement using a high-temperature gas. Thereby, molecular-related ions of heat-unstable components and nonvolatile components became detectable. The deprotonated molecular ion of glycyrrhizic acid (m/z 821), which is unstable at high temperatures, was detected without pyrolysis by ultrasonic mist–DART-MS using unheated helium gas, although it was not detected by normal DART-MS using heated helium gas. The cationized molecular ions of derivatives of polyethylene glycol fatty acid monoesters, which are nonvolatile compounds, were also detected as m/z peaks observed from 800 to 2300. Although the protonated molecular ion of tocopherol acetate was not detected in ionization by ultrasonic mist, it was detected by ultrasonic mist–DART-MS even in the emulsion. It was not necessary to dissolve a sample completely to detect its ions. This method enabled us to obtain the composition of pharmaceutical applications simply and rapidly. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic event tree analysis with the SAS4A/SASSYS-1 safety analysis code

The consequences of a transient in an advanced sodium-cooled fast reactor are difficult to capture with the traditional approach to probabilistic risk assessment (PRA). Numerous safety-relevant systems are passive and may have operational states that cannot be represented by binary success or failure. In addition, the specific order and timing of events may be crucial which necessitates the use of dynamic PRA tools such as ADAPT. The modifications to the SAS4A/SASSYS-1 sodium-cooled fast reactor safety analysis code for linking it to ADAPT to perform a dynamic PRA are described. A test case is used to demonstrate the linking process and to illustrate the type of insights that may be gained with this process. Finally, newly-developed dynamic importance measures are used to assess the significance of reactor parameters/constituents on calculated consequences of initiating events.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗