Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Mass Spectra Deconvolution of Gaseous Mixtures Containing Volatile Organic Compounds

The Spacecraft Atmosphere Monitor (S.A.M.) analyzes all gaseous pollutants in the 1-150Th mass-to-charge range based on their positive-ion mass spectra. Of particular interest is the Trace Gas Analysis (TGA) mode of operation in which S.A.M detects minute amounts of volatile organic compounds (VOC). Pollutant component of the ambient air is sampled on demand in twenty full mass spectra per second. All spectra is accumulated in two-second intervals by an on-board Field Programmable Gate Arrays (FPGA) unit. Mass spectra represents the number of detected fragment ions in a given mass-to-charge ratio channel. Electron impact ionization of neutral molecules results in creation of numerous fragment ions and most of organic compounds will contribute several identical fragments. Despite the presence of these molecular isobars, we developed the deconvolution algorithm capable of identifying target species based on their characteristic fragmentation patterns. We investigate the efficiency of deconvolution algorithm as a function of mass resolution with which mass spectrum is acquired. Higher the mass resolution, better the chances are to distinguish between stereoisomers using their fragmentation propensities, but also results in higher data volumes to be processed by a set of small footprint software stacks hosted by an on-board computer. Finding the balance between deconvolution accuracy and generated data volume under time constrains and limited computing resources is the main topic of this study.

Darrach, M.↗

Development of Computational Environmental Microbiome Workflows for the Laboratory and the International Space Station

Identification of microorganisms in the spaceflight environment is critical for crew health risk assessment on the International Space Station (ISS). Since 2017, nanopore sequencing technology has been used to support thein situ identification of microbial species during spaceflight. Beginning in 2018, a culture-independent, swab-to-sequencer method was implemented onboard the ISS to provide a more thorough insight of the ISS microbiome. Eliminating microbial culture enables identification of difficult-to-culture organisms, reduces risks associated with potentially pathogenic cultures, and could significantly reduce the time from sample-to-answer. However, this molecular-based approach generates large metagenomic datasets that require substantial computational resources for analysis. To process nanopore-generated sequencing data, the JSC Microbiology Laboratory established a bioinformatics workflow on Amazon EC2 under the security guidance of the NASA Science Managed Cloud Environment (SMCE).This resource allows for the development, testing, and accessing of computational tools for processing large and complex datasets. The work described here will address the downlinking of data from the ISS, the automated pipeline developed to identify targeted bacterial and fungal organisms, and the time from sampling onboard to microbial identification. The pipelines have been enhanced to address high and low biomass samples using optimization based on sample source (air, water, or surface) and type of collection (filter, colony, or swab).The resulting microbiome data can be assessed beyond microbial identifications to gain understanding toward population changes over time, potential selective environmental pressures, and evaluating correlations with a wide range of additional data sets. Metagenome analysis pipelines in development could allow for simultaneous identification of microbial species, gene function, and gene pathways present in the environment. Beyond the ground processing, the developed analysis pipeline is currently deployed onboard the ISS to allow for near real-time assessments of the ISS microbiome. This study serves as a critical foundation for exploration missions, where rapid microbiome analyses will be required.

G. Marie Sharp↗

A High-Speed Z-Axis MEMS STM Nanopositioner

Scanning tunneling microscope (STM) is a powerful and versatile tool, not only capable of obtaining topographic information at atomic levels from a conductive surface, but also suited for patterning, manipulation and other applications, all with unprecedented precision. A typical STM’s operation relies on the quantum tunneling phenomenon. Providing a few angstroms of tip-sample separation, and a bias voltage between the two, a tunneling current (TC) is established. The tunneling current is logarithmically proportional to the tip sample separation . During imaging, a three degree of freedom (DOF) piezotube is employed to scan the tip over the surface, while a PI controller drives the Z axis in order to maintain the tunneling current at the set value. Therefore, an image of the sample surface can be constructed using the Z axis controller output, along with the corresponding X, and Y coordinates from the piezotube. Despite its well-established use in high precision applications, the achievable scan speed of the conventional STM has remained limited since its advent. One of the main reasons limiting the achievable scan speed is the relatively low operation bandwidth of the bulky piezotube Z-axis positioner, which is typically less than 1 kHz in conventional systems . This limitation correspondingly hinders the ability of the Z-axis controller to rapidly respond to the changes in the topography during the scan. To address this limitation, we design, build and characterize a high-bandwidth, 1-DOF nanopositioner with an electrostatic parallel plate actuation mechanism and a conductive tip, to replace the Z axis of the currently available STM piezotubes (Figure 1). The device is microfabricated using an SOI wafer with two device layers, where the top-most layer is designated for the tunneling current sensing, and contains the conductive tip realized by FIB induced deposition. The bottom device layer, on the other hand, comprises the actuation mechanism along with the shuttle and mechanical flexures, that provides 2-µm displacement range in one direction, comparable to a typical STM piezoelectric tube scanner. Importantly, the nanopositioner is structurally designed to have a -3dB bandwidth of 15.6 kHz, increasing the STM positioners’ Z axis bandwidth more than an order of magnitude as experimentally shown in Figure 2. Using this system we were able to demonstrate that tunneling current can be successfully established on an HOPG sample in air and successfully maintained for over two minutes (Figures 3-4).

FIB↗

Prototype development and test results of a continuous ambient air monitoring system for hydrazine at the 10 ppb level

A Hydrazine Vapor Area Monitor (HVAM) system is currently being field tested as a detector for the presence of hydrazine in ambient air. The MDA/Polymetron Hydrazine Analyzer has been incorporated within the HVAM system as the core detector. This analyzer is a three-electrode liquid analyzer typically used in boiler feed water applications. The HVAM system incorporates a dual-phase sample collection/transport method which simultaneously pulls ambient air samples containing hydrazine and a very dilute sulfuric acid solution (0.0001 M) down a length of 1/4 inch outside diameter (OD) tubing from a remote site to the analyzer. The hydrazine-laden dilute acid stream is separated from the air and the pH is adjusted by addition of a dilute caustic solution to a pH greater than 10.2 prior to analysis. Both the dilute acid and caustic used by the HVAM are continuously generated during system operation on an "as needed" basis by mixing a metered amount of concentrated acid/base with dilution water. All of the waste water generated by the analyzer is purified for reuse by Barnstead ion-exchange cartridges so that the entire system minimizes the generation of waste materials. The pumping of all liquid streams and mixing of the caustic solution and dilution water with the incoming sample are done by a single pump motor fitted with the appropriate mix of peristaltic pump heads. The signal to noise (S/N) ratio of the analyzer has been enhanced by adding a stirrer in the MDA liquid cell to provide mixing normally generated by the high liquid flow rate designed by the manufacturer. An onboard microprocessor continuously monitors liquid levels, sample vacuum, and liquid leak sensors, as well as handles communications and other system functions (such as shut down should system malfunctions or errors occur). The overall system response of the HVAM can be automatically checked at regular intervals by measuring the analyzer response to a metered amount of calibration standard injected into the dilute acid stream. The HVAM system provides two measurement ranges (threshold limit value (TLV): 10 to 1000 parts per billion (ppb)/LEAK: 100 ppb to 10 parts per million (ppm)). The LEAK range is created by dilution of the sulfuric acid/hydrazine liquid sample with pure water. This dual range capability permits the analyzer to quantify ambient air samples whose hydrazine concentrations range from 10 ppb to as high as 10 ppm. The laboratory and field prototypes have demonstrated total system response times on the order of 10 to 12 minutes for samples ranging from 10 to 900 ppb in the lLV mode and is greater than 2 minutes for samples ranging from 100 to 1300 ppb in the LEAK mode. Service intervals of over 3 months have been demonstrated for continuous 24 hour/day, 7 day/week usage. The HVAM is made up of a purged cabinet that contains power supplies, RS422 signal transmission capabilities, a UPS, an on-site warning system, and a Line Replaceable Unit (LRU). The LRU includes all of the liquid flow system, the analyzer, the control/data system microprocessor and assorted flow and liquid-level sensors. The LRU is mounted on a track slide system so it can be serviced inplace or totally removed and quickly exchanged with another calibrated unit, thus minimizing analyzer downtime. Once an LRU is removed from an analyzer enclosure, it can be brought to a laboratory facility for complete calibration and periodic maintenance.

Meneghelli, Barry↗

Molecular characterization of free tropospheric aerosol collected at the Pico Mountain Observatory: a case study with a long-range transported biomass burning plume

Free tropospheric aerosol was sampled at the Pico Mountain Observatory located at 2225 m above mean sea level on Pico Island of the Azores archipelago in the North Atlantic. The observatory is located ~ 3900 km east and downwind of North America, which enables studies of free tropospheric air transported over long distances. Aerosol samples collected on filters from June to October 2012 were analyzed to characterize organic carbon, elemental carbon, and inorganic ions. The average ambient concentration of aerosol was 0.9 ± 0.7 μg m -3 . On average, organic aerosol components represent the largest mass fraction of the total measured aerosol (60 ± 51%), followed by sulfate (23 ± 28%), nitrate (13 ± 10%), chloride (2 ± 3%), and elemental carbon (2 ± 2%). Water-soluble organic matter (WSOM) extracted from two aerosol samples (9/24 and 9/25) collected consecutively during a pollution event were analyzed using ultrahigh-resolution electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. Approximately 4000 molecular formulas were assigned to each of the mass spectra in the range of m/z 100–1000. The majority of the assigned molecular formulas had unsaturated structures with CHO and CHNO elemental compositions. FLEXPART retroplume analyses showed the sampled air masses were very aged (average plume age > 12 days). These aged aerosol WSOM compounds had an average O/C ratio of ~ 0.45, which is relatively low compared to O/C ratios of other aged aerosol. The increase in aerosol loading during the measurement period of 9/24 was linked to biomass burning emissions from North America by FLEXPART retroplume analysis and Moderate Resolution Imaging Spectroradiometer (MODIS) fire counts. This was confirmed with biomass burning markers detected in the WSOM and with the morphology and mixing state of particles as determined by scanning electron microscopy. The presence of markers characteristic of aqueous-phase reactions of phenolic species suggests that the aerosol collected at the Pico Mountain Observatory had undergone cloud processing before reaching the site. Finally, the air masses of 9/25 were more aged and influenced by marine emissions, as indicated by the presence of organosulfates and other species characteristic of marine aerosol. The change in the air masses for the two samples was corroborated by the changes in ethane, propane, and ozone, morphology of particles, as well as by the FLEXPART retroplume simulations. This paper presents the first detailed molecular characterization of free tropospheric aged aerosol intercepted at a lower free troposphere remote location and provides evidence of low oxygenation after long-range transport. We hypothesize this is a result of the selective removal of highly aged and polar species during long-range transport, because the aerosol underwent a combination of atmospheric processes during transport facilitating aqueous-phase removal (e.g., clouds processing) and fragmentation (e.g., photolysis) of components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DEVELOPMENT OF A TAMPER RESISTANT/INDICATING AEROSOL COLLECTION SYSTEM FOR ENVIRONMENTAL SAMPLING AT BULK HANDLING FACILITIES

Environmental sampling has become a key component of International Atomic Energy Agency (IAEA) safeguards approaches since its approval for use in 1996. Environmental sampling supports the IAEA's mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a Nation State. Swipe sampling is the most commonly used method for the collection of environmental samples from bulk handling facilities. However, augmenting swipe samples with an air monitoring system, which could continuously draw samples from the environment of bulk handling facilities, could improve the possibility of the detection of undeclared activities. Continuous sampling offers the opportunity to collect airborne materials before they settle onto surfaces which can be decontaminated, taken into existing duct work, filtered by plant ventilation, or escape via alternate pathways (i.e. drains, doors). Researchers at the Savannah River National Laboratory and Oak Ridge National Laboratory have been working to further develop an aerosol collection technology that could be installed at IAEA safeguarded bulk handling facilities. The addition of this technology may reduce the number of IAEA inspector visits required to effectively collect samples. The principal sample collection device is a patented Aerosol Contaminant Extractor (ACE) which utilizes electrostatic precipitation principles to deposit particulates onto selected substrates. Recent work has focused on comparing traditional swipe sampling to samples collected via an ACE system, and incorporating tamper resistant and tamper indicating (TRI) technologies into the ACE system. Development of a TRI-ACE system would allow collection of samples at uranium/plutonium bulk handling facilities in a manner that ensures sample integrity and could be an important addition to the international nuclear safeguards inspector's toolkit. This work was supported by the Next Generation Safeguards Initiative (NGSI), Office of Nonproliferation and International Security (NIS), National Nuclear Security Administration (NNSA).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Components Refurbishment and Chemical Analysis Facility, Hot Spot 1 Solid Waste Management Unit #041 Year 4 Annual Performance Monitoring Report Kennedy Space Center, Florida

This Year 4 Annual Performance Monitoring Report (PMR) presents the operations, maintenance, and monitoring activities for the Hydraulic Containment System (HCS) Interim Measure (IM) at the Components Refurbishment and Chemical Analysis (CRCA) facility located at John F. Kennedy Space Center (KSC), Florida. The primary objective of the HCS is to attain hydraulic control of the dissolved-phase chlorinated volatile organic compound (CVOC) plume, with the secondary objective to reduce concentrations of CVOCs in the high-concentration plume to support transition to monitored natural attenuation (MNA). CRCA has been designated Solid Waste Management Unit 041 under the KSC Resource Conservation and Recovery Act Corrective Action Program. The timeframe for activities documented in this Year 4 PMR extends from November 2022 through September 2023. Baseline sampling activities were completed in June 2019, and full-scale startup of the HCS IM was completed in July-August 2019. The operational runtime of the HCS for the Year 4 reporting period was approximately 94%, with the majority of downtime attributed to associated groundwater sampling events, maintenance, and Hurricane Nicole. Almost five million gallons of groundwater were treated during Year 4 of HCS operations, and concentrations of the site’s contaminants of concern (trans-1,2-dichloroethene and vinyl chloride) have been reduced by over 99%. This PMR describes the activities that were performed during Year 4 to operate and monitor the HCS IM, which includes three extraction wells, seven injection wells, and conveyance piping to a modular structure containing the control panel and an air stripper. Influent and effluent sampling results from the air stripper show that the system is operating as designed and is reducing concentrations of contaminants of concern to below detection limits. In addition to HCS operation, this PMR also discusses performance monitoring that has been implemented to assess progress of the HCS IM and overall plume conditions through scheduled groundwater (quarterly and semi-annual) and sub-slab soil gas (quarterly) sampling and analysis. Two ambient air samples were also collected on a quarterly basis in the vicinity of the modular structure and the paved driveway east of the Solvent Reclamation Area during routine operation and maintenance (O&M) activities to ensure safe breathing zone air quality for on-site personnel. All sub-slab soil gas and ambient air sampling conducted during the Year 4 operational period showed results below applicable regulatory air screening limits. Predictions made during the Year 2 groundwater model updates were in close correlation to post Year 4 plume conditions. A supplemental DPT study conducted in 2022 and 2023. This study indicated that low-concentration plume conditions, where concentrations exceed State of Florida Groundwater Cleanup Target Levels, expanded westward to Kennedy Parkway North and northward to the vicinity of the railroad tracks. Based on these results, recommendations were made to install 14 wells to monitor the downgradient and boundary conditions of the expanded LCP. The contents of this Year 4 PMR were presented during the November 2023 KSC Remediation Team meeting, where Team consensus was reached on several items including continued O&M of the HCS, and continued monitoring of groundwater, ambient air, and sub-slab soil gas. Sampling for per- and polyfluoroalkyl substances at CRCA is ongoing and will be submitted under separate cover.

K. Alex Murphy↗

Concurrent measurement of microbiome and allergens in the air of bedrooms of allergy disease patients in the Chicago area

The particulate and biological components of indoor air have a substantial impact on human health, especially immune respiratory conditions such as asthma. To better explore the relationship between allergens, the microbial community, and the indoor living environment, we sampled the bedrooms of 65 homes in the Chicago area using 23the patient-friendly Inspirotec electrokinetic air sampling device, which collects airborne particles for characterization of both allergens and microbial DNA. The sampling device captured sufficient microbial material to enable 16S rRNA amplicon sequencing data to be generated for every sample in the study. Neither the presence of HEPA filters nor the height at which the air sampling device was placed had any influence on the microbial community profile. A core microbiota of 31 OTUs was present in more than three quarters of the samples, comprising around 45% of the relative sequence counts in each bedroom. The most abundant single organisms were Staphylococcus, with other core taxa both human and outdoor-associated. Bacterial alpha diversity was significantly increased in bedrooms that reported having open windows, those with flowering plants in the vicinity, and those in homes occupied by dogs. Porphyromonas, Moraxella, Sutterella, and Clostridium, along with family Neisseraceae, were significantly enriched in homes with dogs; interestingly, cats did not show a significant impact on microbial diversity or relative abundance. While dog allergen load was significantly correlated with bacterial alpha diversity, the taxa that significantly correlated with allergen burden did not exclusively overlap with those enriched in homes with dogs. Alternaria allergen load was positively correlated with bacterial alpha diversity, while Aspergillus allergen load was negatively correlated. The Alternaria allergen load was also significantly correlated with open windows. Microbial communities were significantly differentiated between rural, suburban, and urban homes and houses that were physically closer to each other maintained significantly more similar microbiota. We have demonstrated that it is possible to determine significant associations between allergen burden and the microbiota in air from the same sample and that these associations relate to the characteristics of the home and neighborhoods.

59 BASIC BIOLOGICAL SCIENCES↗

Subtask 3.9 - Direct Coal Liquefaction Process Development

The Energy and Environmental Research Center (EERC), in partnership with the U.S. Department of Energy (DOE) and Accelergy Corporation, an advanced fuels developer with technologies exclusively licensed from ExxonMobil, undertook Subtask 3.9 to design, build, and preliminarily operate a bench-scale direct coal liquefaction (DCL) system capable of converting 45 pounds/hour of pulverized, dried coal to a liquid suitable for upgrading to fuels and/or chemicals. Fabrication and installation of the DCL system and an accompanying distillation system for off-line fractionation of raw coal liquids into 1) a naphtha middle distillate stream for upgrading and 2) a recycle stream was completed in May 2012. Shakedown of the system was initiated in July 2012. In addition to completing fabrication of the DCL system, the project also produced a 500-milliliter sample of jet fuel derived in part from direct liquefaction of Illinois No. 6 coal, and submitted the sample to the Air Force Research Laboratory (AFRL) at Wright Patterson Air Force Base, Dayton, Ohio, for evaluation. The sample was confirmed by AFRL to be in compliance with all U.S. Air Force-prescribed alternative aviation fuel initial screening criteria.

01 COAL, LIGNITE, AND PEAT↗

An example of estimates of precipitable water derived from Nimbus-7 SMMR satellite measurements and FGGE upper air data

A sample of results from the Scanning Multichannel Microwave Radiometer (SMMR) instrument aboard the Nimbus-7 satellite is compared with those obtained from analyses of First GARP Global Experiment Level III-b data collected over the South Pacific on January 10-18, 1979, when the South Pacific Convergence Zone and its accompanying cloud band were quasi-stationary features of this ocean's circulation. It is found that the patterns of Goddard Laboratory for Atmospheres precipitable water values compare well with patterns of the SMMR brightness temperature differences.

Miller, Douglas K.↗

Lessons from 18 Years of Hyperspectral Infrared Sounder Data

By the end of 2013 NASA and EUMETSAT will have accumulated more than 11 years of AIRS, 6 years of IASI and one year of CrIS data. All three instruments were nominally specified to support the NWC for short term weather forecasting with a five year lifetime, but continue to exceed the accuracy requirement needed for weather forecasting alone. This allows use of their data for a much broader range of applications, including the calibration of broad-band instruments in space and climate research. We illustrate calibration aspects with examples from AIRS, IASI and CrIS using spatially uniform clear conditions, simultaneous nadir overpasses and random nadir samples. The differences between AIRS, IASI and CrIS for the purpose of weather forecasting are small and we expect that the excellent forecast impact demonstrated by the combination of AIRS and IASI will be continued by the combination of CrIS and IASI. Clear data are useful for calibration, but contain no climate signal. The analysis of random nadir samples from AIRS and CrIS identifies larger biases for observation of extreme conditions, represented by 1% and 99%tile data than for non-extreme observations. This is relevant for climate analysis. Resolution of these differences require further work, since they can complicate the continuation of trends established by AIRS with CrIS data, at least for extrema. The unequaled stability of the AIRS data allows us to evaluate trends using random nadir sampled data. We see an increasing frequency in severe storms over land, a decreasing frequency over ocean. The 11 years of AIRS data are too short to tell if these trends are significant from a climate change viewpoint, or if they are parts of multi-decadal oscillations.

CRIS↗

Components Refurbishment and Chemical Analysis Facility, Hot Spot 1 SWMU #041 Year 3 Annual Performance Monitoring Report Kennedy Space Center, Florida

This Year 3 Annual Performance Monitoring Report (PMR) presents the operations, maintenance, and monitoring activities for the Hydraulic Containment System (HCS) Interim Measure (IM) at the Components Refurbishment and Chemical Analysis (CRCA) facility located at John F. Kennedy Space Center (KSC), Florida. The primary objective of the HCS is to attain hydraulic control of the dissolved-phase chlorinated volatile organic compound (CVOC) plume, with the secondary objective to reduce concentrations of CVOCs in the high-concentration plume to support transition to monitored natural attenuation (MNA). CRCA has been designated Solid Waste Management Unit 041 under the KSC Resource Conservation and Recovery Act Corrective Action Program. The timeframe for activities documented in this Year 3 PMR extends from September 2021 through October 2022. Baseline sampling activities were completed in June 2019, and full-scale startup of the HCS IM was completed in July-August 2019. The operational runtime of the HCS for the Year 3 reporting period was approximately 91%, with the majority of downtime attributed to system maintenance and repair. This is generally consistent with Year 1 and Year 2 runtimes of 85% and 92%, respectively. To help reduce downtime, an anti-scaling amendment, Redux 390, has been used to reduce scaling and help maintain system design parameters. Over nine million gallons of groundwater were treated during Year 3 of HCS operations, and concentrations of the site’s contaminants of concern (trans-1,2-dichloroethene and vinyl chloride) have been reduced by over 97%. This PMR describes the activities that were performed during Year 3 to operate and monitor the HCS IM, which includes three extraction wells, seven injection wells, and conveyance piping to a modular structure containing the control panel and an air stripper. Influent and effluent sampling results from the air stripper show that the system is operating as designed and is reducing concentrations of contaminants of concern to below detection limits. In addition to HCS operation, this PMR also discusses performance monitoring that has been implemented to assess progress of the HCS IM and overall plume conditions through scheduled groundwater (quarterly and semi-annual) and sub-slab soil gas (quarterly) sampling and analysis. Two ambient air samples were also collected on a quarterly basis in the vicinity of the modular structure and the paved driveway east of the Solvent Reclamation Area during routine operation and maintenance (O&M) activities to ensure safe breathing zone air quality for on-site personnel. All sub-slab soil gas and ambient air sampling conducted during the Year 3 operational period showed results below applicable regulatory air screening limits. Predictions made during the Year 2 groundwater model updates were in close correlation to post Year 3 plume conditions. Therefore, it can be assumed that the projected path remains valid for transition to MNA in one to two years of continuous HCS operation. The contents of this Year 3 PMR were presented during the February 2023 KSC Remediation Team meeting, where Team consensus was reached on several items including continued O&M of the HCS, and continued monitoring of groundwater, ambient air, and sub-slab soil gas. Replacement of MW0019 and VMP04 was also recommended, as well as additional direct-push technology sampling to further delineate the downgradient plume and confirm overall site-wide low-concentration plume boundaries. Sampling for per- and polyfluoroalkyl substances at CRCA is ongoing and will be submitted under separate cover.

K. Alex Murphy↗

Stability of magnetocaloric La(Fe x Co y Si 1-x-y ) 13 in water and air

Stability of cobalt-doped lanthanum iron silicide, La(Fe x Co y Si 1-x-y ) have been investigated under conditions required for magnetocaloric refrigeration. The XRD analysis revealed that both milled and non-milled samples stored in water loose a few Bragg peaks corresponding to the NaZn13 phase of La(Fe x Co y Si 1-x-y ) . Samples stored in air show well-defined Bragg peaks similar to that of pristine material. The SEM-EDS of the milled and non-milled samples stored in water and air show an increased concentration of oxygen in the samples, particularly those treated with water. The course non-milled powders kept in air and water show sharp transitions at the Curie temperature T C = 300K without large magnetization above the T C . The milled, fine-particulate sample stored in air shows a slightly broadened transition at T C , and that stored in deionized water for 14 days shows significantly broadened transition from 300K and retains large magnetizations above 400 K. This is indicative of relatively fast hydrolysis and removal of some or all of La, likely as hydroxide, from fine powders, leaving behind La-poor or, potentially, La-free Fe-Co-Si containing ferromagnetic residue with much higher Curie temperature. The non-milled course sample stored in water exhibits sharper magnetic transition and higher magnetization hence it shows the highest entropy change among all 4 type of samples.

36 MATERIALS SCIENCE↗

Measurement of Passive Uptake Rates for Volatile Organic Compounds on Commercial Thermal Desorption Tubes and the Effect of Ozone on Sampling

Diffusive or passive sampling methods using commercially filled axial-sampling thermal desorption tubes are widely used for measuring volatile organic compounds (VOCs) in air. The passive sampling method provides a robust, cost effective way to measure air quality with time-averaged concentrations spanning up to a week or more. Sampling rates for VOCs can be calculated using tube geometry and Fick’s Law for ideal diffusion behavior or measured experimentally. There is evidence that uptake rates deviate from ideal and may not be constant over time. Therefore, experimentally measured sampling rates are preferred. In this project, a calibration chamber with a continuous stirred tank reactor design and constant VOC source was combined with active sampling to generate a controlled dynamic calibration environment for passive samplers. The chamber air was augmented with a continuous source of 45 VOCs ranging from pentane to diethyl phthalate representing a variety of chemical classes and physiochemical properties. Both passive and active samples were collected on commercially filled Tenax TA thermal desorption tubes over an 11-day period and used to calculate passive sampling rates. A second experiment was designed to determine the impact of ozone on passive sampling by using the calibration chamber to passively load five terpenes on a set of Tenax tubes and then exposing the tubes to different ozone environments with and without ozone scrubbers attached to the tube inlet. During the sampling rate experiment, the measured diffusive uptake was constant for up to seven days for most of the VOCs tested but deviated from linearity for some of the more volatile compounds between seven and eleven days. In the ozone experiment, both exposed and unexposed tubes showed a similar decline in terpene mass over time indicating back diffusion when uncapped tubes were transferred to a clean environment but there was no indication of significant loss by ozone reaction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving the thermoelectric performance and thermal stability of Ca 3 Co 4 O 9+δ ceramics by sintering in oxygen atmosphere

We report on the influence of sintering gas atmosphere on the thermoelectric (TE) performance of Ca 3 Co 4 O 9+δ ceramics made from precursor powders synthesized using chemical sol–gel route. Two sets of polycrystalline pellets were sintered in air and oxygen atmosphere, respectively. Sintering gas atmosphere and sintering temperature were found to have great influence on the Ca 3 Co 4 O 9+δ crystal orientation and formation of the Co 3 O 4 secondary phase. All samples, regardless of sintering atmosphere, had similar Seebeck coefficients S that increased with measurement temperature. By contrast, the electrical resistivity ρ changed dramatically as the sintering temperature and atmosphere changed. For samples sintered in air, when the sintering temperature is above 1193 K, ρ increased as the sintering temperature increased. For samples sintering in oxygen, ρ decreased monotonically as the sintering temperature increased up to 1253 K. Benefited from the reduced ρ, the electrical power factor of the sample sintered in the oxygen at 1253 K is 0.539 mW m –1 K –2 , and 40% greater than that from the sample sintered at 1193 K in air. Dimensionless figure-of-merit ZT of the sample sintered at 1253 K in oxygen is 0.28 at 1073 K, which is 20% greater than that of samples sintered in air at 1193 K. Overall, the highest TE performance was obtained for Ca 3 Co 4 O 9+δ ceramics sintered in oxygen at 1253 K, which is significantly higher than the Ca 3 Co 4 O 9+δ decomposition temperature of 1199 K in air.

36 MATERIALS SCIENCE↗

CACTI ARM Aerial Facility Measurements of Ice Nucleating Particles

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0°C down to -26 to -29°C) of atmospheric ice nucleating particle (INP) concentrations taken on the Atmospheric Radiation Measurement (ARM) program Aerial Facilty (AAF) G-1 aircraft. INP measurements on the G-1 were collected from varied altitudes on different flights over the region of the Sierras de Córdoba mountain range of north-central Argentina, centred over ARM's Mobile Facility (AMF-1) near Villa Yacanto, where ground-based INP measures were being taken concurrently. Both studies took place as part of the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) Experiment. A filter sampling system was deployed on the G-1 to collect aerosol particles for post-processing of INPs collected on filters (measuring their immersion freezing ability) once returned to Colorado State University (CSU). Filter holders used were pre-cleaned aluminum in-line units loaded with pre-cleaned and pre-sterilized 47 mm dia. Nuclepore polycarbonate filters (0.2 mm pore size). Filters were drawn for varied times, resulting in varied volumes collected (51 to 1667 SL). Mass flow rate was recorded in real-time so that total sampled volume (at standard temperature and pressure) could be determined. A total of 34 sample filters were collected over the IOP, including 5 blanks. Filters were stored at -20°C freezer prior to frozen return to Colorado State University (CSU). . Processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurment of INPs, collected aerosol particles were re-suspended in 7 mL of 0.02 µm-filtered deionized water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples are cooled at 0.33°C min-1 and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. Aliquots of suspensions from selected samples were also heat treated (95°C for 20 min) to denature and deactivate biological INPs, and digested in 10% H2O2 at 95°C under UV-B to remove all organic carbon INPs. McCluskey, C. S., J. Ovadnevaite, M. Rinaldi, J. Atkinson, F. Belosi, D. Ceburnis, S. Marullo, T. C. J. Hill, U. Lohmann, Z. A. Kanji, C. O’Dowd, S. M. Kreidenweis, P. J. DeMott, 2018: Marine and Terrestrial Organic Ice Nucleating Particles in Pristine Marine to Continentally-Influenced Northeast Atlantic Air Masses, Journal of Geophysical Research: Atmospheres, 123, 6196–6212, https://doi.org/10.1029/2017JD028033. Vali, G., 1971: Quantitative evaluation of experimental results on the heterogeneous freezing nucleation of supercooled liquids. J. Atmos. Sci., 28, 402–409.

54 ENVIRONMENTAL SCIENCES↗

CACTI ARM Mobile Facility (AMF) Measurements of Ice Nucleating Particles

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0°C down to -26 to -29°C) of atmosperic ice nucleating particle (INP) concentrations taken on ARM's Mobile Facility (AMF-1) Aerosol Observing System, near Villa Yacanto in central Argentina, during the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) Experiment. A filter sampler was mounted on the AOS trailer (2 m below the AOS inlet). Single-use filter units open to the atmosphere fitted with pre-cleaned and pre-sterilized, 47-mm dia. Nuclepore polycarbonate filters were used. Filters were typically drawn for an 8-hour period, totaling 6000 liters sampled on average. After collection, filters were stored at -20°C until processed. Initial processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurment of INPs, collected aerosol particles were re-suspended in 7-8 mL of 0.1 µm-filtered deionized (DI) water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples are cooled at 0.33°C min-1 and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. An aliquot of suspension fro selected samples were also heat treated (95°C for 20 min) to denature and deactivate biological INPs, and another aliquot digested in 10% H2O2 at 95°C under UV-B to remove all organic carbon INPs. McCluskey, C. S., J. Ovadnevaite, M. Rinaldi, J. Atkinson, F. Belosi, D. Ceburnis, S. Marullo, T. C. J. Hill, U. Lohmann, Z. A. Kanji, C. O’Dowd, S. M. Kreidenweis, P. J. DeMott, 2018: Marine and Terrestrial Organic Ice Nucleating Particles in Pristine Marine to Continentally-Influenced Northeast Atlantic Air Masses, Journal of Geophysical Research: Atmospheres, 123, 6196–6212, https://doi.org/10.1029/2017JD028033. Vali, G., 1971: Quantitative evaluation of experimental results on the heterogeneous freezing nucleation of supercooled liquids. J. Atmos. Sci., 28, 402–409.

54 ENVIRONMENTAL SCIENCES↗