Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Calibration of a Gas Monitor Detector using a Cryogenic Radiometer for Measuring the Radiant Power of Extreme Ultraviolet Free Electron Laser at SPring-8

A gas monitor detector was calibrated to a cryogenic radiometer for measuring the radiant power of EUV-FEL (extreme ultraviolet free electron laser) at the wavelengths of 51 nm and 61 nm. The output signals of the gas monitor detector showed good linearity against the radiant power measured by the radiometer in the range from 6 {mu}W to 160 {mu}W. The calibration coefficients of the gas monitor detector are determined with the relative standard uncertainty of around 5 %.

43 PARTICLE ACCELERATORS↗

Development of an X-ray Pinhole Monitor at NSRRC

An X-ray pinhole monitor is designed to measure the size, emittance and energy spread of the electron beam at NSRRC. The profile of the electron beam in a synchrotron radiation source is commonly assessed with a pinhole monitor of a cheap and simple design. To increase the resolution of the measurement, one method is to use the X-ray regime. The beam passes through a pinhole and the low-energy photons are eliminated with a filter. The beam profile is imaged with a fluorescent screen. The pinhole dimension is optimized on minimizing the diffraction blurring and maximizing the geometric resolution. The X-ray pinhole monitor is simulated with a SRW program. We designed an X-ray pinhole monitor to have three sets of pinhole array, six sets of filters and three sets to screens to increase the information acquired about the characteristics of the X-ray pinhole monitor. The simulation and design are presented here.

43 PARTICLE ACCELERATORS↗

Use of a synchronization card for XMCD measurements at the XMaS Beamline

X-ray Magnetic Circular Dichroism (XMCD) spectra from a 5 {mu}m polycrystalline Gd foil were measured in transmission across the Gd L{sub 2,3} edges using the Multipurpose Unit for Synchronisation, Sequencing and Triggering (MUSST) card developed at the European Synchrotron Radiation Facility (ESRF). The circularly polarized x-rays were produced by a diamond phase-plate and their helicity was rapidly reversed through the use of a piezo driven device. The signal measured for each helicity was recorded by the MUSST card synchronized to the helicity reversal. The results are compared to those obtained using an analogue lock-in technique.

43 PARTICLE ACCELERATORS↗

The RIKEN Materials Science Beamline at SPring-8: Towards Visualization of Electrostatic Interaction

In order to visualize molecular interaction by the experimental electrostatic potential analysis we have optimized the optical parameters and developed the high-resolution Debye-Scherrer camera at the RIKEN materials science beamline, BL44B2 of SPring-8. For the purpose the camera was designed to be equipped with the hybrid X-ray detector system. One is the conventional detector, the imaging plate readout off-line to carry out high d(interplanar spacing)-resolution measurements and the other is the CCD detector, which can be operated in a camera at variable distances for high angle-resolution measurements. In addition we have been developing an in-situ properties measurement system to visualize the electrostatic interaction completely synchronized with material functions.

43 PARTICLE ACCELERATORS↗

Extremely High Resolution Single Crystal Diffractometory for Orbital Resolution using High Energy Synchrotron Radiation at SPring-8

The investigation of accurate structure at charge density level will not only understand the function mechanism of physical property but also lead to design new functional materials. We have successfully installed large cylindrical camera at the BL02B1/SPring-8. In conceptual design, the image plate (IP) was selected as the detector, because such IP will not only detect wide range in one shot but also yield reliable data. In commissioning, the performance of this camera demonstrated to be suitable for the direct observation of d-electron system.

43 PARTICLE ACCELERATORS↗

New micro-beam beamline at SPring-8, targeting at protein micro-crystallography

A new protein micro-crystallography beamline BL32XU at SPring-8 is under construction and scheduled to start operation in 2010. The beamline is designed to provide the stabilized and brilliant micro-beam to collect high-quality data from micro-crystals. The beamline consists of a hybrid in-vacuum undulator, a liquid-nitrogen cooled double crystal monochromator, and K-B focusing mirrors with large magnification factor. Development of data acquisition system and end station consists of high-precision diffractometer, high-efficiency area detector, sample auto-changer etc. are also in progress.

43 PARTICLE ACCELERATORS↗

Quantum-dot-array diffraction grating with single order diffraction property for soft x-ray region

A gold transmission grating is used routinely to disperse the x-ray spectrum at the Z soft x-ray facility to measure the spectrum and temporal history of the absolute soft x-ray power emitted from z-pinch and hohlraum radiation sources. A quantum-dot-array diffraction grating (QDADG) of 250 lines/mm for soft x-ray is designed and fabricated for the first time according to the principle of binary sinusoidal transmission grating. The diffraction efficiencies of the grating are measured in the 150-300 eV photon energy range on the Beamline 3W1B of Beijing Synchrotron Radiation Facility. This article describes the basic concept and calibration techniques and presents calibration results. It is shown that the 250 lines/mm QDADG can be used to disperse light without higher-order diffractions in soft x-ray range, and the diffraction efficiencies of this grating are nearly constant (about 25%), which is beneficial in the spectrum analysis.

43 PARTICLE ACCELERATORS↗

Electroproduction of Excited Baryons with the CLAS Detector in Hall B of Jefferson Lab

Recent results from Jefferson Lab (JLab) on the extraction of single-and double-polarization observables in both the 1{pi}-and 2{pi}-channel show their high sensitivity to resonant production amplitudes and therefore their importance for the extraction of resonance parameters. The CEBAF Large Acceptance Spectrometer (CLAS) has access to the baryon resonance (N*) form factors at high Q{sup 2}, which is advantageous for the study of the dynamical properties of nucleon resonances. In anticipation of the 12 GeV energy upgrade to JLab, our group plans to extract the electromagnetic transition form factors (electrocouplings) for many well-established excited nucleon states in the unexplored domain of Q{sup 2}>5 GeV{sup 5}. The expected data on resonance electro-couplings will allow us to systematically explore how in the strong interaction regime of QCD bare quarks are dressed with gluons and how quark cores of the various N* states emerge from QCD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gas loading apparatus for the Paris-Edinburgh press

We describe the design and operation of an apparatus for loading gases into the sample volume of the Paris-Edinburgh press at room temperature and high pressure. The system can be used for studies of samples loaded as pure or mixed gases as well as for loading gases as pressure-transmitting media in neutron-scattering experiments. The apparatus consists of a high-pressure vessel and an anvil holder with a clamp mechanism. The vessel, designed to operate at gas pressures of up to 150 MPa, is used for applying the load onto the anvils located inside the clamp. This initial load is sufficient for sealing the pressurized gas inside the sample containing gasket. The clamp containing the anvils and the sample is then transferred into the Paris-Edinburgh press by which further load can be applied to the sample. The clamp has apertures for scattered neutron beams and remains in the press for the duration of the experiment. The performance of the gas loading system is illustrated with the results of neutron-diffraction experiments on compressed nitrogen.

43 PARTICLE ACCELERATORS↗

The Search for Exotic Mesons in {gamma}p{yields}{pi}{sup +{pi}+{pi}-}n with CLAS at Jefferson Lab

In addition to ordinary qq-bar pairs, quantum chromodynamics (QCD) permits many other possibilities in meson spectra, such as gluonic hybrids, glueballs, and tetraquarks. Experimental discovery and study of these exotic states provides insight on the nonperturbative regime of QCD. Over the past twenty years, some searches for exotic mesons have met with controversial results, especially those obtained in the three-pion system. Prior theoretical work indicates that in photoproduction one should find gluonic hybrids at significantly enhanced levels compared to that found in pion production. To that end, the CLAS g12 run was recently completed at Jefferson Lab, using a liquid hydrogen target and tagged photons from a 5.71 GeV electron beam. The CLAS experimental apparatus was modified to maximize forward acceptance for peripheral production of mesons. The resulting data contains the world's largest 3{pi} photoproduction dataset, with {gamma}p{yields}{pi}{sup +{pi}+{pi}-}n events numbering in the millions. Early results describing the data quality, kinematics, and dysnamics will be shown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exclusive Photoproduction of K + Σ* - (n) Off Deuteron

We are using the CEBAF Large Acceptance Spectrometer (CLAS) to study the exclusive photoproduction of K + Σ* - (1385) off the deuteron. It will be the first published total cross section of this reaction channel. We show the preliminary results of the total cross section, while we present all the key steps of achieving it. In order to study the reaction mechanism, we also study and show the angular distribution in the Gottfried-Jackson frame.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Induced Polarization of {Lambda}(1116) in Kaon Electroproduction with CLAS

The CLAS Collaboration is using the p(e, e'K{sup +}p){pi}{sup -} reaction to measure the induced polarization of the electroproduced {Lambda}(1116). In this experiment a 5.499-GeV electron beam was incident upon an unpolarized liquid-hydrogen target. The CEBAF Large Acceptance Spectrometer (CLAS) was used to detect the scattered electron, the kaon, and the decay proton from the {Lambda} hyperon. CLAS allowed for a large kinematic acceptance in Q{sup 2}(0.75{<=}Q{sup 2{<=}}3.5 GeV{sup 2}) and W(1.6{<=}W{<=}3.0 GeV), as well as the kaon center-of-mass scattering angle. The goal is to map out the kinematic dependencies for the induced polarization in order to provide new constraints on models of K-hyperon production. Along with previously published photo- and electroproduction cross sections and polarization observables from CLAS, LEPS, SAPHIR, and GRAAL, these new induced polarization data are needed in coupled-channel analyses to search for previously unobserved s-channel resonances. Preliminary polarization results are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectroscopy of {Lambda} hypernuclei in the (e, e'K{sup +}) reaction at Jefferson Lab

The coincidence experiment E01-011 (HKS), conducted in Hall C at Jefferson Laboratory in fall 2005, represents a new generation of high resolution {Lambda} hypernuclei spectroscopy experiments. It exploits the benefits of the associated electroproduction mechanism via the (e, e'K{sup +}) reaction. Compared with the widely studied meson-induced reactions, the higher quality quasi-continuous electron beam produces the potential for high resolution energy spectra. Further, it provides information complementary to meson-induced reactions: light neutron-rich and mirror hypernuclei, enhanced population of states accessible by spin-flip channels. The newly introduced tilt method of the electron spectrometer (ENGE) greatly reduced the rate of the background electrons due to Bremsstrahlung and Moeller scattering. A brand new high resolution kaon spectrometer (HKS) together with a sophisticated detector package yielded excellent PID and momentum resolution. This resulted in quality missing mass spectra with energy resolution of approximately 400-500 keV (FWHM), an unprecedented value in hypernuclear reaction spectroscopy. The experiment measured the spectra of exotic neutron rich and mirror {Lambda} hypernuclei {sub {Lambda}}{sup 7}He, {sub {Lambda}}{sup 12}B, {sub {Lambda}}{sup 28}Al with high statistics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scintillating screens sensitivity and resolution studies for low energy, low intensity beam diagnostics

In order to investigate the limits of scintillating screens for beam profile monitoring in the ultra-low energy, ultra-low intensity regime, CsI:Tl, YAG:Ce, and a Tb glass-based scintillating fiber optic plate (SFOP) were tested. The screens response to 200 and 50 keV proton beams with intensities ranging from a few picoampere down to the subfemtoampere region was examined. In the following paper, the sensitivity and resolution studies are presented in detail for CsI:Tl and the SFOP, the two most sensitive screens. In addition, a possible use of scintillators for ultra-low energy antiproton beam monitoring is discussed.

43 PARTICLE ACCELERATORS↗

A surface work function measurement technique utilizing constant deflected grazing electron trajectories: Oxygen uptake on Cu(001)

We report on the application of a novel nondestructive in-vacuum technique for relative work function measurements, employing a grazing incidence electron deflection above a sample with a planar surface. Two deflected electron beam detectors are used as a position sensitive detector to control feedback to the sample potential as the sample work function changes. With feedback the sample potential exactly follows the surface sample-size averaged work function variation, so that the deflected beam trajectory remains stable. We also discuss methods to optimize the initial electron trajectories for this method, so as to minimize unwanted effects such as from uncontrolled external magnetic fields. As the electron beam does not impinge on the surface in this new technique electron induced desorption, ionization, dissociation, and/or decomposition is not induced at the interface. Importantly also the technique allows for free access to the surfaces enabling simultaneous deposition/evaporation and/or application of other surface characterization methods. We demonstrate its application in concurrent measurements of helium atom reflectivity and work function changes taking place during molecular oxygen exposure of a Cu(001) surface. A work function measurement sensitivity and stability is demonstrated at {approx}10 mV at a sampling rate of 1 Hz and after application of an {approx}7 s smoothing routine. In comparison to the helium atom reflectivity measurements, the work function measurements are more sensitive to the initial O uptake, and less so to the final coverage variations and possible surface reordering at higher O coverages.

43 PARTICLE ACCELERATORS↗

Development of a synchrotron biaxial tensile device for in situ characterization of thin films mechanical response

We have developed on the DIFFABS-SOLEIL beamline a biaxial tensile machine working in the synchrotron environment for in situ diffraction characterization of thin polycrystalline films mechanical response. The machine has been designed to test compliant substrates coated by the studied films under controlled, applied strain field. Technological challenges comprise the sample design including fixation of the substrate ends, the related generation of a uniform strain field in the studied (central) volume, and the operations from the beamline pilot. Preliminary tests on 150 nm thick W films deposited onto polyimide cruciform substrates are presented. The obtained results for applied strains using x-ray diffraction and digital image correlation methods clearly show the full potentialities of this new setup.

36 MATERIALS SCIENCE↗

High-performance soft x-ray spectromicroscopy beamline at SSRF

The Shanghai Synchrotron Radiation Facility (SSRF) is the first third-generation synchrotron facility in China and operated at an electron energy of 3.5 GeV. One of the seven beamlines in the first construction phase is devoted to soft x-ray spectromicroscopy and is equipped with an elliptically polarized undulator light source, a plane grating monochromator, and a scanning transmission x-ray microscope end station. Initial results reveal the high performance of this beamline, with an energy resolving power estimated to be over 10 000 at the argon L-edge and a spatial resolution better than 30 nm.

43 PARTICLE ACCELERATORS↗

Note: A helical velocity selector for continuous molecular beams

We report on a modern realization of the classic helical velocity selector for gas phase particle beams. The device operates stably under high vacuum conditions at rotational frequencies limited only by commercial dc motor capabilities. Tuning the rotational frequency allows selective scanning over a broad velocity band. The width of the selected velocity distributions at full-width-half-maximum is as narrow as a few percent of the selected mean velocity and independent of the rotational speed of the selector. The selector generates low vibrational noise amplitudes comparable to mechanically damped state-of-the-art turbo-molecular pumps and is therefore compatible with vibration sensitive experiments like molecule interferometry.

43 PARTICLE ACCELERATORS↗