Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerated degradation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Oxidation Behavior of Ni-Based Alloys Fabricated by Additive Manufacturing

Additive manufacturing (AM) allows for the fabrication of complex near net shape components, leading to new design opportunities and significant savings, for example by decreasing tooling and materials cost or by accelerating prototype development. New Ni-based alloy heat exchangers with thin-walled areas exposed to hot gases will, however, suffer from corrosion degradation, and the high temperature oxidation performance of AM alloys needs to be addressed. Alloy N06002 (Ni-22Cr-18Fe-9Mo) fabricated by electron beam melting (EBM) and selective laser melting (SLM) along with EBM-fabricated N07247 and modified N07247 were cyclic oxidation tested at 950°C in air and humid air for durations ranging from 100 h to 5000 h. Increased spallation rates were observed initially for the AM N06002 alloys in comparison with wrought N06002 alloy because of the AM alloy specific microstructures. After ~2000 h, the situation was reversed with significant spallation observed for the wrought HX alloy only. Low mass gains were observed for the EBM N07247 alloys at 950°C, but thick oxide scales were observed locally due to the presence of oxidized cracks. Massive oxidation of these cracks led to fast oxidation rates at 1100°C.

Dryepondt, Sebastien N.↗

LONG TERM AGING AND SURVEILLANCE OF 9975 PACKAGE COMPONENTS

The mission of the 9975 package, originally designed only for transportation of radioactive materials, has been broadened to include storage at the Savannah River Site. Two components of this package, namely the containment vessel O-rings and fiberboard overpack, require continued integrity assessment under the storage conditions. The performance of the components over time is being evaluated using accelerated-aging studies. Compression stress relaxation (CSR) and leak testing are being used to measure the performance of O-rings. The performance of the fiberboard is being evaluated using compression strength, thermal conductivity, specific heat capacity and other physical properties. Models developed from the data collected provide an initial prediction of service life for the two components, and support the conclusion that normal service conditions will not degrade the performance of the package beyond specified functional requirements for the first assessment interval. Increased confidence in this conclusion is derived from field surveillance data and destructive evaluation of packages removed from storage.

42 ENGINEERING↗

Use of indentation to study the degradation of photovoltaic backsheets

The ability of electrical insulating materials within a module to act as insulators is a key safety requirement for photovoltaic (PV) technology. Presently, however, the durability of backsheets may not be readily assessed. For example, the mechanical tensile test continues to be developed, and its use has not been validated such that a technically based pass/fail criteria may be established. This study examines the use of simple indentation methods, including durometer hardness and instrumented indentation, as a means to quantitively assess the degradation of PV backsheets. Characteristics including: hardness, modulus, load/displacement profile, creep hold response, and residual impression are explored in an empirical study. Glass/encapsulant/backsheet mini-modules constructed using backsheets including: polyamide (PA), poly(ethylene terephthalate) (PET), polyvinyl fluoride (PVF) laminate ('TPE'), and polyvinylidene fluoride (PVDF) were examined. An M-type durometer as well as Berkovich and cube-corner tips were used in the indentation experiments. Additional characterizations were performed to interpret the indentation measurements including: surface roughness measurements using atomic force microscopy (AFM), a chemical integrity study using Fourier-transform infrared spectroscopy (FTIR), and phase-transition measurements using differential scanning calorimetry (DSC). The results are analyzed in the context of the combined accelerated stress test (C-AST) also explored in this study. Instrumented indentation (i.e., using a Berkovich tip) was able to distinguish between backsheets and quantify the effects of accelerated testing (including up to 60%, 25%, and 20% change in hardness, modulus, and creep displacement, respectively). The embrittlement of the backsheets was not readily assessable using cube-corner indentation. Cracking of the known-bad polyamide backsheet was observed from the C-AST, which was not observed to result from steady state UV weathering.

14 SOLAR ENERGY↗

Flexible Fabric-Based IDC Sensors for Conformal Curved Surface Applications

Interdigital capacitor (IDC) sensors are attractive in-situ sensors that can be used to measure permittivity variations in materials. Such sensors could be powerful enablers for cable insulation aging detection. Since insulation aging is correlated with a change in its material permittivity an IDC can measure that change via its measured capacitance. A new thin, flexible fabric-based IDC sensor is introduced for application on conformal curved surfaces such as an electrical cable surface. A multielectrode IDC and its backplane were fabricated using conductive copper polyester taffeta fabrics that were adhesively bonded to nonconductive polyester fabric. The sensor because of its soft flexible structure eliminates the problem of sensor conductor damage which is common for printed circuit board (PCB) type sensors when conformed to the surface of a cable. It also significantly reduces the airgap between the electrodes and the surface that they must contact in order to measure the capacitance. Airgap reduction and consistency are important in order to accurately predict permittivity variations in cable insulation material due to aging. Both PCB-based sensors and the new fabric-based sensors were built and tested on unaged cables and cables that underwent accelerated aging. Results demonstrate the proposed advantages of the novel fabric-based IDC sensor.

interdigital capacitor sensor, IDC, NDE, PCB senso↗

Degradation of impact toughness in cast stainless steels during long-term thermal aging

Cast austenitic stainless steels (CASSs) have been extensively used for the large components of nuclear reactor primary coolant systems. Since the cast steels inevitably contain degradable metastable phases and replacement of the large coolant system components is impractical, the thermal embrittlement of CASS components has been a serious concern in the extended-term operation of nuclear power plants. This study aimed to systematically measure and analyze the effect of long-term thermal aging on the Charpy impact toughness to provide a comprehensive understanding of thermal degradation behavior and a practical aging model to predict the degree of thermal degradation in the cast stainless steels. Additionally, the materials tested in the research include eight CASS alloys (two CF3s, one CF3M, three CF8s, and two CF8Ms) and two reference wrought materials (304L and 316L), in which the nominal δ-ferrite content ranges from ~2% to 33%. These stainless steels have been thermally aged at two light water reactor (LWR) temperatures (290 and 330 °C) and at two accelerated-aging temperatures (360 and 400 °C) for up to 30,000 h; these include both under-aged and over-aged conditions relative to the extended service lifetime (80 years). Charpy impact testing was performed for aged and non-aged specimens, and the impact (absorbed) energy parameters were correlated with a new aging parameter (A). Both the reduction of impact fracture toughness and the shift of ductile-brittle transition temperature were strongly dependent on the δ-ferrite content and degree of thermal aging. A linear relationship was found between the increasing rate of the index transition temperature T 41J and aging parameter A; base on which an empirical model was proposed for prediction of the transition temperature as a simple function of the aging parameter (A) and δ-ferrite content (F). Finally, the critical aging parameter for embrittlement (AC) was evaluated and compared with the existing δ-ferrite content criteria.

36 MATERIALS SCIENCE↗

Spiral Orbit Tribometer

The spiral orbit tribometer (SOT) bridges the gap between full-scale life testing and typically unrealistic accelerated life testing of ball-bearing lubricants in conjunction with bearing ball and race materials. The SOT operates under realistic conditions and quickly produces results, thereby providing information that can guide the selection of lubricant, ball, and race materials early in a design process. The SOT is based upon a simplified, retainerless thrust bearing comprising one ball between flat races (see figure). The SOT measures lubricant consumption and degradation rates and friction coefficients in boundary lubricated rolling and pivoting contacts. The ball is pressed between the lower and upper races with a controlled force and the lower plate is rotated. The combination of load and rotation causes the ball to move in a nearly circular orbit that is, more precisely, an opening spiral. The spiral s pitch is directly related to the friction coefficient. At the end of the orbit, the ball contacts the guide plate, restoring the orbit to its original radius. The orbit is repeatable throughout the entire test. A force transducer, mounted in-line with the guide plate, measures the force between the ball and the guide plate, which directly relates to the friction coefficient. The SOT, shown in the figure, can operate in under ultra-high vacuum (10(exp -9) Torr) or in a variety of gases at atmospheric pressure. The load force can be adjusted between 45 and 450 N. By varying the load force and ball diameter, mean Hertzian stresses between 0.5 and 5.0 GPa can be obtained. The ball s orbital speed range is between 1 and 100 rpm.

Pepper, Stephen V.↗

Degradation in PV Encapsulant Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test

Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PV installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.

14 SOLAR ENERGY↗

Conditioning of BPM pickup signals for operations of the Duke storage ring with a wide range of single-bunch current

The Duke storage ring is a dedicated driver for the storage ring based oscillator free-electron lasers (FELs), and the High Intensity Gamma-ray Source (HIGS). Furthermore, it is operated with a beam current ranging from about 1 mA to 100 mA per bunch for various operations and accelerator physics studies. High performance operations of the FEL and γ-ray source require a stable electron beam orbit, which has been realized by the global orbit feedback system. As a critical part of the orbit feedback system, the electron beam position monitors (BPMs) are required to be able to precisely measure the electron beam orbit in a wide range of the single-bunch current. However, the high peak voltage of the BPM pickups associated with high single-bunch current degrades the performance of the BPM electronics, and can potentially damage the BPM electronics. A signal conditioning technique using low pass filters is developed to reduce the peak voltage to protect the BPM electronics, and to make the BPMs capable of working with a wide range of single-bunch current. Simulations and electron beam based tests are performed. The results show that the Duke storage ring BPM system is capable of providing precise orbit measurements to ensure highly stable FEL and HIGS operations.

43 PARTICLE ACCELERATORS↗

Aging Behavior of Viton{sup R} O-Ring Seals in the 9975 Shipping Package - 12594

The Savannah River Site (SRS) is storing plutonium (Pu) materials in the K-Area Materials Storage (KAMS) facility. The Pu materials were packaged according to the DOE-STD-3013 standard and shipped to the SRS in Type B 9975 packages. The robust 9975 shipping package was not designed for long-term product storage, but it is a specified part of the storage configuration and the KAMS facility safety basis credits the 9975 design with containment. Within the 9975 package, nested stainless steel containment vessels are closed with dual O-ring seals based on Viton{sup R} GLT or GLT-S fluoro-elastomer. The aging behavior of the O-ring compounds is being studied to provide the facility with advanced notice of nonconformance and to develop life prediction models. A combination of field surveillance, leak testing of surrogate fixtures aged at bounding service temperatures, and accelerated-aging methodologies based on compression stress-relaxation and oxygen consumption analysis is being used to evaluate seal performance. A summary of the surveillance program relative to seal aging behavior is presented. The aging behavior of fluoro-elastomer seals based on Viton{sup R} GLT and GLT-S is being studied to develop life prediction models in support of long-term storage of plutonium materials in the 9975 shipping packages at the Savannah River Site. Field surveillance data in combination with accelerated-aging data suggest a significant lifetime for the seals. Typical storage conditions are not anticipated to challenge the leak-tightness of the seals for many years. Early life prediction models based on compression stress relaxation indicate a seal lifetime of ∼12 years at the maximum service temperature predicted (93 deg. C). Seal lifetimes at lower, more realistic conditions are likely significantly longer. Service life predictions based on CSR data are thus far conservative relative to predictions based on time to leakage failure. Surveillance data on packages examined after 6 years in storage show only minor compression set of the O-rings and no significant degradation. Surveillance and testing will continue as needed to validate and refine life prediction models. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neutron radiation hardness testing of 650V / 7.5 A GaN power HEMT

In this work, we have performed neutron radiation hardness testing for commercially available 650 V/7.5 A GaN power HEMT. The devices were tested at Los Alamos Neutron Science Center (LANSCE) inside Irradiation of Chips Electronics, ICE house-1 at a flux density of 10(6) n/cm(2) -s and energy level above 1 MeV, which is approximately 10(6) times higher than neutron radiation at airliner flight height (30,000 ft). During the experiments, the devices were stressed electrically, thermally and irradiated with neutron radiation. We have observed degradation of AlGaN layer due to accelerated neutron radiation (1.54 x 10(10) n/cm(2) above 1.5 MeV neutron energy) under electrical stress condition. We have performed parametric defect analysis through step-by-step application of neutron irradiation, thermal stress and electrical bias, and observed highest degradation of threshold voltage (0.14 V) for combined electrical stress and neutron irradiation.

36 MATERIALS SCIENCE↗

Note: Inhibiting bottleneck corrosion in electrical calcium tests for ultra-barrier measurements

A major failure mechanism is identified in electrical calcium corrosion tests for quality assessment of high-end application moisture barriers. Accelerated calcium corrosion is found at the calcium/electrode junction, leading to an electrical bottleneck. This causes test failure not related to overall calcium loss. The likely cause is a difference in electrochemical potential between the aluminum electrodes and the calcium sensor, resulting in a corrosion element. As a solution, a thin, full-area copper layer is introduced below the calcium, shifting the corrosion element to the calcium/copper junction and inhibiting bottleneck degradation. Using the copper layer improves the level of sensitivity for the water vapor transmission rate (WVTR) by over one order of magnitude. Thin-film encapsulated samples with 20 nm of atomic layer deposited alumina barriers this way exhibit WVTRs of 6 × 10{sup −5} g(H{sub 2}O)/m{sup 2}/d at 38 °C, 90% relative humidity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

IOTA experiment for proton pulse compression at extreme space-charge

The longitudinal compression of intense proton bunches with strong space-charge force is an essential component of a proton driver for a muon collider. We propose a proton bunch compression experiment at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab to explore optimal radio frequency (RF) cavity and lattice configurations. IOTA is a compact fixed-energy storage ring dedicated to beam physics R&D that can circulate a 2.5-MeV proton beam with extreme space-charge. Using ImpactX and its 3D space-charge solver, simulations indicate that bunch length can be rapidly reduced by a factor of at least two, without appreciable degradation in transverse beam quality, even under strong space-charge conditions. However, longitudinal defocusing presents a large effect in short-pulsed proton beams, and the optimization of bunch compression under such conditions is discussed.

Simons, Benjamin [Northern Illinois U.; Fermilab]↗

PRESERVATION OF THE HIGH QUALITY FACTOR AND ACCELERATING GRADIENT OF Nb3Sn-COATED CAVITY DURING PAIR ASSEMBLY

Two CEBAF 5-cell accelerator cavities have been coated with Nb3Sn film using the vapor diffusion technique. One cavity was coated in the Jefferson Lab Nb3Sn cavity coating system, and the other in the Fermilab Nb3Sn coating system. Both cavities were measured at 4 K and 2 K in the vertical dewar test in each lab and then assembled into a cavity pair at Jefferson Lab. Previous attempts to assemble Nb3Sn cavities into a cavity pair degraded the superconducting properties of Nb3Sn-coated cavities. This contribution discusses the efforts to identify and mitigate the pair assembly challenges and will present the results of the vertical tests before and after pair assembly. Notably, one of the cavities reached the highest gradient above 80 mT in the vertical test after the pair assembly.

Eremeev, G.V.↗

Preservation of the High Quality Factor and Accelerating Gradient of Nb3Sn-coated Cavity During Pair Assembly

Two CEBAF 5-cell accelerator cavities have been coated with Nb3Sn film using the vapor diffusion technique. One cavity was coated in the Jefferson Lab Nb3Sn cavity coating system, and the other in the Fermilab Nb3Sn coating system. Both cavities were measured at 4 K and 2 K in the vertical dewar test in each lab and then assembled into a cavity pair at Jefferson Lab. Previous attempts to assemble Nb3Sn cavities into a cavity pair degraded the superconducting properties of Nb3Sn-coated cavities. This contribution discusses the efforts to identify and mitigate the pair assembly challenges and will present the results of the vertical tests before and after pair assembly. Notably, one of the cavities reached the highest gradient above 80 mT in the vertical test after the pair assembly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of Composite Insulators Used for Electric Transmission under Extreme Climatic Conditions

Composite or polymeric insulators are being used in various parts of the world for high-voltage transmission and distribution lines. In some parts of India, places in the states like Rajasthan and Gujarat experience an increase in the daytime temperature up to 50 °C, while the nighttime temperature reduces as low as 3-5 °C. Because of these extreme temperature variations along with electric stress and humidity conditions, composite insulators have to perform well over their lifetime to ensure the reliability of the transmission network. In the present work, experimental conditions are simulated with temperature variation from 50 to 3-5 °C along with electrical stress, humidity variation, pollution, and ultraviolet radiations. Accelerated aging studies with these stresses are conducted to understand the degradation on the insulator similar to the field conditions. Surface resistivity measurements, leakage current analysis, and surface degradation studies using thermogravimetric analysis, scanning electron microscopy, energy-dispersive x-ray, and Fourier transform infrared spectroscopy (FTIR) are conducted. Some interesting results obtained from the study are presented. Experimentation under extreme conditions with polluted insulators showed considerable degradation which was inferred from the material testing analysis. The insulator slabs on which electrical stress was not applied showed a considerable peak at 1500 cm{sup −1} in the FTIR spectra, indicating the generation of low molecular weight PDMS chains from the bulk due to UV aging and thermal stress, while the degradation pattern of non-polluted sample was severe compared to the slab treated but was considerably less severe in comparison with the polluted insulator sample exhibiting pollution can considerably increase degradation rate.

36 MATERIALS SCIENCE↗

Simulation and Experimental Results of Interdigital Capacitor (IDC) Sensors to Monitor Insulation Degradation of Cables

The efficacy of using interdigital capacitor (IDC) sensors to monitor cable insulation aging was studied through electromagnetic simulations and experimental measurements. Simulation results on both planar and conformal dielectric materials indicated that IDCs on thin substrates and with conducting backplanes provide superior performance in terms of higher capacitance. An airgap study showed that even a very small airgap between the sensor and the cable’s insulation results in significant reduction in capacitance; therefore, airgaps should be minimized. Finally, cables that underwent accelerated aging exposure in an oven were tested using fabricated IDC sensors. Measurement results showed a 12.5% increase in capacitance when the IDC was pressed against the insulation versus a 91.3% increase in capacitance when the IDC was pressed against the jackets of the cables for cable specimens ranging from unaged to aged 35 days.

Cable NDE, Interdigital Capacitance↗

The Role of Bearing and Scan Mechanism Life Testing in Flight Qualification of the MODIS Instrument

The Moderate Resolution Imaging Spectroradiometer (MODIS) is an instrument aboard the Terra (EOS AM-11) satellite and has been operating successfully since December 1999. MODIS has been viewing the entire Earth's surface and gathering data to better understand the global dynamics and processes occurring on land, in the oceans, and in the lower atmosphere. All observations are made through an extremely high resolution, optically and mechanically precise, scan mirror motor/encoder assembly. The reliable performance of this assembly depends on two duplex bearing pairs lubricated with Pennzane, a synthetic hydrocarbon, formulated with lead napthanate. This paper describes the results of accelerated and operational life tests. It also describes the post-test analyses of the disassembled bearings. Analyses were performed using micro-Raman, micro-FTIR, X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), and Size Exclusion Chromatography (SEC). In general, the three sets of bearings in each of the test stations were in very good condition after accumulating 68, 144, and 209 million revolutions, respectively. Some of the bearings exhibited lubricant degradation, indicated by viscous lubricant deposits on the cage and raceways.

VanDyk, Steven G.↗

The Role of Bearing and Scan Mechanism Life Testing in Flight Qualification of the MODIS Instrument

The Moderate Resolution Imaging Spectroradiometer (MODIS) is an instrument aboard the Terra (EOS AM-1) satellite and has been operating successfully since December 1999. MODIS has been viewing the entire Earth's surface and gathering data to better understand the global dynamics and processes occurring on land, in the oceans, and in the lower atmosphere. All observations are made through an extremely high resolution, optically and mechanically precise, scan mirror motor/encoder assembly. The reliable performance of this assembly depends on two duplex bearing pairs lubricated with Pennzane, a synthetic hydrocarbon, formulated with lead napthanate. This paper describes the results of accelerated and operational life tests. It also describes the post-test analyses of the disassembled bearings. Analyses were performed using micro-Raman, micro-FTIR, X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), and Size Exclusion Chromatography (SEC). In general, the three sets of bearings in each of the test stations were in very good condition after accumulating 68, 144, and 209 million revolutions, respectively. Some of the bearings exhibited lubricant degradation, indicated by viscous lubricant deposits on the cage and raceways.

VanDyk, Steven G.↗