Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerated Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Infant Mortality and Wear-Out Failures in Polymer and MnO2 Tantalum Capacitors

Reliability testing of modern tantalum capacitors shows the presence of both types, infant mortality (IM) and wearout (WO) failures. To assure reliable operation, the probability of IM failures should be reduced to below the specified level, and the time of WO inception should be greater than the required useful life of the parts at operation conditions. In this work, several types of MnO2 and polymer cathode tantalum capacitors have been tested at highly accelerated conditions to assess voltage acceleration factors, determine adequate burn-in conditions, and assess the useful life. A modified time dependent dielectric breakdown (TDDB) model has been suggested to explain both types of failure, and a physical mechanism of degradation that is based on migration and reactions of oxygen vacancies explains increase of the defect related, IM failures with the level of stress.

tantalum capacitors↗

Mesoscale Modeling of the Effects of Accelerated Burnup on UO2 Microstructural Evolution

Accelerating the nuclear fuel qualification process will rely on some combination of advanced modeling and simulation techniques with accelerated irradiation testing and separate effects experiments to enable the development of new fuel concepts in a shorter time frame. One of the key challenges to successfully leveraging accelerated irradiation tests will be understanding the artifacts that may be introduced with accelerated accumulation of dose and/or burnup. This work presents phase field (MARMOT) simulations of the evolution of representative 2D UO2 microstructures up to 40 MWd/kgU. Simulations were performed under both commercial light water reactor fuel conditions as well as those that would be expected for highly accelerated (~10x) burnup conditions similar to those used in the MiniFuel irradiations in Oak Ridge National Laboratory’s High Flux Isotope Reactor. The phase field model was coupled with a discrete nucleation algorithm to model re- structuring at high burnup. The effect of the different fission rates in both microstructures was investigated at two temperatures: 650?C and 800?C. The lower temperature simulations both showed an onset of restructuring at nearly 60 MWd/kgU. More extensive restructuring was obtained in the MiniFuel microstructure compared with that of the PWR fuel. At 800?C, no restructuring was obtained as a result of the thermally activated diffusion of Xe atoms and U vacancies to fission gas bubbles, which reduces the nucleation driving force. These results highlight the importance of using modeling and simulation tools to inform the environmental conditions during targeted accelerated irradiation tests to extract the most useful fuel performance data.

accelerated fuel qualification, Phase Field, Restr↗

Ferrographic analysis of wear debris generated in accelerated rolling element fatigue tests

The types and quantities of wear particles generated during accelerated ball rolling contact fatigue tests were determined. Ball specimens were made of AMS 5749, a corrosion resistant, high-temperature bearing steel. The lubricant was a super-refined naphthenic mineral oil. Conditions included a maximum Hertz stress of 5.215 times 10 to the 9th power Pa and a shaft speed of 10,000 rpm. Four types of wear particles were observed; normal rubbing wear particles, fatigue spall particles, spheres, and friction polymer.

Jones, W. R., Jr.↗

Performance and durability of electrically conductive tape for shingled Si heterojunction technology cells

We report electrically conductive tape (ECT) was characterized and used to assemble shingled cell strings at low temperature to achieve high reliability Pb- and Ag-free interconnections. The volume resistivity for two considered ECTs are 0.13 ± 0.06 mΩ·cm and 0.47 ± 0.20 mΩ·cm and specific contact resistances, 6.85± 2.00 mΩ·cm 2 and 6.30 ± 0.37 mΩ·cm 2 using the emerging IEC 62788-8-1 Technical Specification for assessment of electrically conductive adhesives (ECA). Durability and performance of the technology in glass–glass mini modules were evaluated with temperature cycling, damp heat testing, and combined-accelerated stress testing (CAST). Through temperature cycling (-40°C to 85°C) applying five times the mini module short-circuit current in forward bias and in the multi climate CAST protocol, there was negligible degradation of fill factor after replacing connectors at the modules' cable leads; however, CAST resulted in short circuit current loss attributed to degradation in light collection by the cells, not the ECT. The IEC 61215-2 85°C, 85% relative humidity damp heat testing showed susceptibility of the HJT cells to effects of humidity in the electroluminescence intensity around the module perimeter that degraded power performance by 4% (relative). Contrasting the IEC 61215-2 qualification testing-based damp heat testing with CAST, factors such as the optical stress of CAST may precipitate the degradation of the modules whereas the humidity levels and duration of IEC 61215-2 damp heat testing may lead to excessive levels of humidity diffused into the modules, potentially resulting in degradation that is unrepresentative of the field.

14 SOLAR ENERGY↗

Investigation of reliability attributes and accelerated stress factors on terrestrial solar cells

The accelerated stress test results obtained on all terrestrial solar cells since the inception of the program are summarized. Tested cells were grouped according to the method used to form the conductive metallization layer: solder dipped, vacuum deposited, screen printed, and copper plated. Although metallization systems within each group were quite similar, they differed in numerous details according to the procedures employed by each manufacturer. Test results were summarized for all cells according to both electrical degradation and catastrophic mechanical changes. These results indicated a variability within each metallization category which was dependent on the manufacturer. Only one manufacturer was represented in the copper plated category and, although these showed no signs of detrimental copper diffusion during high temperature testing, their metallization was removed easily during high humidity pressure cooker testing. Preliminary testing of encapsulated cells showed no major differences between encapsulated and unencapsulated cells when subjected to accelerated testing.

Lathrop, J. W.↗

Corrosion of metal particle and metal evaporated tapes

Very high coercivity metal particle (MP) and metal evaporated (ME) tapes are being used in 8mm video and digital audio tape applications, and more recently in digital data recording applications. In view of the inherent susceptibility of such media to environmental corrosion, a number of recent studies have addressed their long term stability and archivability. These studies have used an accelerated corrosion test based either on elevated temperature-humidity or polluting gas atmospheres known as Battelle tests. A comparison of the Battelle test results performed at different laboratories reveals a large variation from one location to another, presumably due to incorrect replication of the Battelle condition. Furthermore, when the Battelle tests are performed on enclosed cartridges, it is quite possible that diffusion limits the penetration of the extremely low concentration polluting gaseous species to the inner layers of the tapes during the short time of the accelerated test, whereas in real life these diffusion limitations may not apply. To avoid this uncertainty, the corrosion behavior of commercial 8mm MP and ME tapes when cassettes without their external plastic cases were exposed to 50 deg C and 80 percent RH for 7.5 weeks is investigated.

Speliotis, Dennis E.↗

Ferrographic analysis of wear debris generated in accelerated rolling element fatigue tests

Ferrographic analysis was used to determine the types and quantities of wear particles generated during accelerated rolling contact fatigue tests. The NASA five-ball rolling contact fatigue tester was used. Ball specimens were made of AMS 5749, a corrosion-resistant high-temperature bearing steel. The lubricant was a super-refined naphthenic mineral oil. Conditions included a maximum Hertz stress of 5.52 billion Pa and a shaft speed of 10,000 rpm. Four types of wear particles were observed: normal rubbing wear particles, fatigue spall particles, spheres, and friction polymer.

Jones, W. R., Jr.↗

Creep Testing of Vectran Yarn

NASA and industry are developing inflatable space structures to provide deployable habitable volumes for future exploration missions in space and on the surface of the Moon and Mars. These structures must withstand the constant pressure loading of multi-year missions. These missions therefore require excellent creep resistance in the constituent cordage and webbings that provide the primary structure of the vessel, which is typically constructed using high-strength synthetic materials such as Vectran. Real-time and accelerated creep testing of Vectran webbings has been performed at NASA Langley Research Center (LaRC), however, acceptable correlation between the results of the two approaches has not yet been achieved. Given the additional complexity of the webbing architecture, creep testing at the yarn level is being studied to reduce the number of interacting properties and focus on the core creep behavior to see if better correlation can be achieved between real-time and accelerated tests. To achieve this objective a creep test stand that is able to support simultaneous testing of five Vectran yarns had been previously designed and built. The test stand utilizes two clamp-wrap grips to mount the yarn and has a 10:1 load ratio, via a lever-arm, henceforth, known as the lever-arm test stand. Real-time creep testing (without measuring the strain of the yarn) in this fixture produces yarn ruptures in the gauge section. However, a large scatter in the times to failure was seen in the results across multiple loading conditions. For example, a test at 70% of the ultimate tensile strength (UTS) was found to have specimens that failed within a matter of hours and others that took over 6 weeks to fail. Prior test data on Vectran webbings had indicated high variability in the material strength, leading to higher than average scatter in the creep testing of webbings, which could translate to the scatter in creep behavior at the yarn level as well. However, there was still the possibility that the lever-arm test stand was causing the high scatter in data; specifically, due to potential variability in the loading of each specimen. Therefore, an additional creep test setup was designed and built to attempt to determine if the large scatter in the results was due to inherent material properties, the lever-arm test stand, or both. The newly designed creep test stand, henceforth known as the conventional test stand, utilized the more typical method for creep testing which involved hanging a weight from the yarn with no additional load amplification. The conventional test stand was designed and fabricated in-house at LaRC. High speed cameras were used to validate that the specimens in the conventional test stand failed in the gauge section. Once it was determined that the conventional test stand would provide valid failures in the gauge section, creep tests on the Vectran yarns were run to compare to the lever-arm test stand results. Preliminary results for a 70% UTS creep test have some specimens failing within a number of hours and some failing in excess of 6 weeks. These results are similar to those seen on the lever-arm test stand, pointing towards a large variability inherent in the material. The poster/presentation will focus on the design, fabrication, and validation of the conventional test stand as well as present preliminary results comparing the creep data from the conventional and lever-arm test stands

creep testing↗

Preliminary analysis of accelerated space flight ionizing radiation testing

A preliminary analysis shows that radiation dose equivalent to 30 years in the geosynchronous environment can be accumulated in a typical composite material exposed to space for 2 years or less onboard a spacecraft orbiting from perigee of 300 km out to the peak of the inner electron belt (approximately 2750 km). Future work to determine spacecraft orbits better tailored to materials accelerated testing is indicated. It is predicted that a range of 10 to the 9th power to 10 to the 10th power rads would be accumulated in 3-6 mil thick epoxy/graphite exposed by a test spacecraft orbiting in the inner electron belt. This dose is equivalent to the accumulated dose that this material would be expected to have after 30 years in a geosynchronous orbit. It is anticipated that material specimens would be brought back to Earth after 2 years in the radiation environment so that space radiation effects on materials could be analyzed by laboratory methods.

Wilson, J. W.↗

Characterization of wear debris generated in accelerated rolling-element fatigue tests

A ferrographic analysis was used to determine the types and quantities of wear debris generated during accelerated rolling contact fatigue tests. The five-ball rolling contact fatigue tester was used. Ball specimens were made of a corrosion resistant, high-temperature bearing steel. The lubricant was a superrefined naphthenic mineral oil. Conditions included a maximum Hertz stress of 5.52 10 to the 9th power Pa and a shaft speed of 10,000 rpm. Four types of wear debris were observed: (1) normal rubbing wear particles, (2) fatigue microspall particles, (3) spheres, and (4) friction polymer deposits. The characterization of wear debris as a function of time was of limited use in predicting fatigue failures in these accelerated tests.

Jones, W. R., Jr.↗

EdgeCortix SAKURA-I Machine-Learning, PCIe Accelerator SEE Heavy Ion Test Report

To enable autonomy in space, machine-learning and computer vision applications become invaluable for sensor processing. However, these algorithms are computationally complex and unfeasible for many embedded central processing units (CPUs) and usually require external coprocessors, such as graphics processing units (GPUs) or accelerators specific to the application, including application specific integrated circuits (ASICs). In power-constrained systems, GPUs tend to consume more power than is acceptable (>40W), so lower-power accelerators have shown promise to provide the performance needed under spacecraft constraints. For radiation engineers, developing methodologies that can properly test CPUs, GPUs, and accelerators, and enable comparisons between them remains a necessary complication to solve as the devices become more complex. The methodology in this test aims to be a start in developing a baseline single-event effect (SEE) test for client-device machine learning accelerators. This category of devices do not host their own operating system. This testing campaign is a continuation of a previous 200 MeV proton test performed in January 2024. This report covers two heavy ion tests of the SAKURA-I card: one in April 2024, and one in June 2024. Additional data was needed after the April test due to ion-range issues experienced at higher linear-energy transfers (LETs). These range issues are described in more detail in Section 8. This experiment characterizes SEEs and data error susceptibility of the EdgeCortix SAKURA-I machine-learning accelerator under heavy ions. The device was monitored for single event upsets (SEUs) and single event functional interrupts (SEFIs) at the Lawrence Berkeley National Laboratory’s 88-inch cyclotron. The SAKURA-I board accelerates machine-learning inference applications on a host computer through a PCIex16 connection. For the purposes of devising an end to end automated analysis workflow for this experiment, the YOLO-V5 and SSD300 objection-detection models, and the ResNet-50, EfficientNet, and MobileNetV2 image classification models were used as a representative suite of analytical machine-learning models.

Seth S Roffe↗

Testing a Neural Network Accelerator on a High-Altitude Balloon

The cognitive communications project has been working to re d machine learning approaches to support their deployment and sustained use in space environments. It has historically been difficult to implement such techniques on space platforms, however, due to the computational requirements they levy onto general-purpose avionics hardware. While technologies exist to accelerate the computation of aspects of neural networks, such platforms have not historically been deployed in space environments. Given that testing payloads in such environments can be both cost- and time-prohibitive, high-altitude balloons can be used as a way to approximate a space environment at a much lower cost, thus providing a cost-effective way in which to test newer approaches to hardware acceleration for artificial intelligence which may be deployed onto spacecraft more directly. This paper describes a successful test of a commercial off- the-shelf neural network accelerator on a high-altitude balloon. It begins by explaining our selection criteria when evaluating different commercial neural network acceleration techniques: primary considerations include size, weight, and power (SWaP) as well as ease of integration. Next, the paper describes the development and implementation of an experimental flight test platform: flight and ground components are discussed. Afterward, the paper discusses the experimental payload itself: this includes the experimental procedure as well as the specific image and method used for testing. Finally, the paper concludes with an evaluation of both the experimental device tested at altitude as well as the flight test framework itself, identifying how the existing platform can be used to continue tes g commercial off-the-shelf (COTS) solutions for acceleration.

Clark, Gilbert↗

Nanomechanical and Fluorescence Characterizations of Weathered PV Module Encapsulation

Nanoindentation and fluorescence spectroscopy provide spatially resolved mechanical and chemical characterization for degradation of poly (ethylene-co-vinyl acetate) (EVA) encapsulants aged under accelerated weathering and in field deployed photovoltaic (PV) modules. For the accelerated weathering tests, two different EVA formulations in the glass/EVA/glass-laminated coupons were exposed to ultraviolet (UV) light for 180 days at three different temperatures (40, 60, and 80 °C) and UV intensities (0.4, 2.2, and 2.9 W/m2/nm at 340 nm). The fluorescence spectra and moduli were uniform through the cross section of both EVA formulations at the lowest temperature and UV intensity; however, under the highest temperature and UV intensity, the UV irradiated sides showed lower moduli and higher fluorescence compared to the opposite sides. For EVA obtained from PV modules deployed 27 years in Sacramento, CA, USA, changes in fluorescence intensity across the thickness were relatively greater than changes in modulus. On the other hand, for EVA obtained from the same type of module stored in the shed for 27 years, no fluorescence was observed, and a uniform modulus was seen through the EVA layer, but with substantially higher values than those obtained from the field-deployed modules. The different extent of changes between laboratory and field exposures suggests the importance of considering effects of temperature and UV intensity for designing a reliable accelerated testing. This study uniquely demonstrates the capability of microscale characterization using nanoindentation and fluorescence microscopy to monitor mechanical and chemical degradation of EVA encapsulants in PV modules.

14 SOLAR ENERGY↗

A multiphysics model of the versatile test reactor based on the MOOSE framework

The traditional modeling approach for sodium fast reactor cores relies on separate physics models, where the fuel performance, thermal–hydraulics, and neutronics calculations required to predict the core physics characteristics for nominal conditions are decoupled by relying on user-imposed boundary conditions. Here, this paper aims at evaluating the impact of multiphysics simulations for predicting the core characteristics of the Versatile Test Reactor, which is being designed as a 300-MWt sodium-cooled fast reactor. The purpose of the Versatile Test Reactor is to accelerate the testing of advanced nuclear materials in the United States. The proposed multiphysics model relies on the Griffin reactor physics code, the SAM thermal–hydraulic system code, the BISON fuel performance code, as well as generic Multiphysics Object-Oriented Simulation Environment capabilities implemented in the open-source tensor mechanics module. For k eff calculations, the introduction of a tight coupling between the neutronics, thermo-mechanical and thermal–hydraulics models induces a change of around 543 pcm in the eigenvalue, compared to the traditional standalone neutronics calculation where approximate temperature profiles are used. The multiphysics model is then employed for quantifying the impact of the thermal conductivity uncertainties on some of the key figures of merit, such as the fuel centerline temperature, assembly powers, and keff for nominal core conditions. As anticipated, uncertainties on fuel thermal conductivity mostly impact the fuel centerline temperature, and to a lesser extend the k eff .

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sparsely Dispersed CeO x ‑Stabilized Pt Nanoparticles Overcome Pt Loading–Durability Trade-Off for Highly Durable Heavy-Duty Fuel Cells

Proton-exchange-membrane fuel cells (PEMFCs) are clean and sustainable mobile power sources for transportation. Recently, their deployment in heavy-duty vehicles (HDVs) has attracted growing interest owing to their high energy scalability and lower infrastructure requirements. However, to meet the stringent requirements for efficiency and long-term durability for HDV applications, PEMFCs typically employ a relatively high platinum group metal (PGM) loading (>0.2 mg PGM /cm 2 ). This elevated PGM loading significantly increases the stack and system costs, surpassing the U.S. Department of Energy (DOE) target of $\$ 60$/kW for commercial viability. Reducing PGM loading while maintaining performance and durability remains a central challenge for HDV fuel cells. Here we exploit metal oxide–Pt interactions and utilize the strong CeO x –Pt interaction to design a CeO x @Pt catalyst structure with exceptional durability. At a low total PGM loading (0.1 mg PGM /cm 2 ), the CeO x @Pt/C catalyst demonstrates high fuel cell performance (8.8 kW/g PGM ) and stability (power retention >90%) after the challenging HDV durability testing (90,000 accelerated-stress-test cycles). With the CeO x @Pt/C catalyst, we showcase over 70% reduction in Pt cost from the M2FCT target (to $\$ 9$/kW), highlighting its promising potential for enabling stable and cost-effective fuel cell systems for heavy-duty applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solar cell contacts

Two experimental contact systems were examined and compared to a baseline contact system consisting of evaporated layers of titanium, palladium, and silver and an electroplated layer of copper. The first experimental contact system consisted of evaporated layers of titanium, nickel, and copper and an electroplated layer of copper. This system performed as well as the baseline system in all respects, including its response to temperature stress tests, to a humidity test, and to an accelerated aging test. In addition, the cost of this system is estimated to be only 43 percent of the cost of the baseline system at a production level of 25 MW/year. The second experimental contact system consisted of evaporated layers of nickel and copper and an electroplated layer of copper. Cells with this system show serious degradation in a temperature stress test at 350 C for 30 minutes. Auger electron spectroscopy was used to show that the evaporated nickel layer is not an adequate barrier to copper diffusion even at temperatures as low as 250 C. This fact brings into question the long-term reliability of this contact system.

Meier, D. L.↗