Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ablation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Alternative High Performance Polymers for Ablative Thermal Protection Systems

Ablative thermal protection systems are commonly used as protection from the intense heat during re-entry of a space vehicle and have been used successfully on many missions including Stardust and Mars Science Laboratory both of which used PICA - a phenolic based ablator. Historically, phenolic resin has served as the ablative polymer for many TPS systems. However, it has limitations in both processing and properties such as char yield, glass transition temperature and char stability. Therefore alternative high performance polymers are being considered including cyanate ester resin, polyimide, and polybenzoxazine. Thermal and mechanical properties of these resin systems were characterized and compared with phenolic resin.

Ablator↗

Multi-Scale Modeling of Low-Density Carbon-Phenolic Ablators

Protecting a spacecraft during atmospheric entry is one of highest risk factors that needs to be mitigated during design of a space exploration mission. At entry speeds from space, air turns into high-temperature plasma, and spacecraft Thermal Protection Systems (TPS) are needed to protect the vehicle payload. Modern successful material architectures of spacecraft shields use a porous carbon fiber substrate impregnated with phenolic as an ablator material. In the lecture, efforts to build a Predictive Material Modeling framework for porous ablators from micro-scale to macro-scale will be presented. Several numerical methods and techniques will be summarized that use voxelized images to compute geometrical properties of the porous substrate. These computed properties include porosity, specific surface area and tortuosity that are otherwise indirectly measured through experimental techniques. Direct simulation Monte Carlo (DSMC), a particle-based method for approximating the Boltzmann equation, is used to compute the permeability coefficient of the porous substrate based on its digitized representation. The method computes the flow within the microstructure, where the size of the pores may approach the mean-free-path of the flow. Finally, a high-fidelity model implemented in PATO (Porous-material Analysis Toolbox) is discussed, and some examples of ablative material response are presented, including for the first time 3D simulations of the full tiled heat shield for the Mars Science Laboratory (MSL) capsule.

Ablators↗

Qualification of Domestic Lyocell Based Phenolic Impregnated Carbon Ablator (PICA-D) for NASA Missions

Phenolic Impregnated Carbon Ablator (PICA) is a low-density ablator that has been used as the planetary entry heatshield for several NASA missions since the late 90’s. Its low density and efficient performance characteristics have proven effective for use from Discovery to Flag-ship class missions, from Sample Return missions such as Stardust, OSIRIS-REx to large Mars Lander missions such as Mars Science Lab (MSL) and Mars 2020. The rayon-based carbon precursor raw material used in PICA preform manufacturing has experienced multiple supply chain issues. The challenge involved in finding a replacement fiber source is in processing as well as in the final performance of the ablator. Each replacement necessitates the requalification of the PICA. This has happened at least twice in the past 25 years, and a third substitution is now needed. Due to the obsolescence of the input foreign rayon fiber source, a new variant of PICA has been developed using a domestic rayon-like fiber source, Lyocell. Due to its flight heritage and proven capability, PICA is baselined as the Thermal Protection System (TPS) for Dragonfly and Mars Sample Return Sample Retrieval Lander mission and is being considered for the backshell of the Mars Sample Return Earth Entry System. All three missions are due to be launched between 2026 and 2028. The challenge this time is to ensure the PICA made with domestic material is a suitable replacement to the heritage PICA used in MSL and Mars 2020 so that the design of the heatshield can be matured without much risk. Results are presented from the recent efforts of 22 PICA-D billets that were Lot Acceptance Tested. Thermal, mechanical, and representative environment arc-jet tests have been conducted. Testing of PICA-Domestic (PICA-D) indicates very comparable performance with respect to “heritage” PICA materials and thus PICA-D is expected to be a sustainable and nearly a “drop-in” replacement solution for future NASA missions.

PICA↗

Simulating Meteor Ablation at the Hypersonic Materials Environmental Test System

The ablation mechanisms of stony meteorite material and a terrestrial analog were investigated at the Hypersonic Materials Environmental Test System (HyMETS) facility at NASA’s Langley Research Center. The primary analyte (Tamdakht-H5) and arc-jet test conditions were chosen to simulate the entry of an ordinary chondrite through the Earth’s mesosphere. Basalt was selected to compare the meteorite response against material with enhanced polymerization and an elevated concentration of volatile species. The initial ablation process for each material commences with the vaporization of volatile species and germination of a viscous melt layer on the stagnation surface. However, each material exhibited distinct mass loss mechanisms, with basalt recessing at twice the rate of Tamdakht. Inspection of high-speed video and chemical analysis of the post-test melt layer suggests the dominant mode of mass loss of Tamdakht is expressed through the vaporization of volatile compounds. Vaporization rates of Tamdakht are 18x higher than basalt under the most severe test conditions which provides enhanced thermal shielding. Furthermore, Tamdakht produces a relatively stable melt flow, as evidenced by perpetual growth at the sidewall and the exiguous detachment of molten material into the flow. The ablation mechanism of basalt is markedly different from Tamdakht and is governed by volatile species in the virgin material. The dominant mode of mass loss for basalt is attributed to the detachment of large sections of the stagnation surface near the edge radius. An additional but subordinate mode of mass loss is assigned to the removal of melt flow as it passes over the edge radius, where shear forces overcome the rheological properties of the molten matter. Finally, mechanistic details will be discussed in terms of designing future test campaigns, developing meteorite-based materials response models, and impacting the broader scope of the Asteroid Threat Assessment Project (ATAP).

Meteor Ablation↗

Identification and Study of Validation Level Test Cases for Computational Modeling of Non-Charring Ablators

Computational modeling of Thermal Protection System (TPS) materials, used for aerospace applications, provides numerous advantages in preliminary selection and design of a heatshield material and shape for atmospheric entry vehicles. However, to serve as a reliable tool for prediction of material thermal and ablative behavior, the modeling approach needs to be validated against real experimental and flight data, preferably at a range of applied conditions. The validation study is typically very complex as it requires reliable measured data not only for the material thermal response and surface recession, but also well characterized environmental conditions. The validation problem becomes even more complex when the material thermal response is dictated by multi-physics effects such as solid conduction, in-depth thermal decomposition, pyrolysis gas flow and chemical reactions. The multi-physics effects complicate not only the modeling effort, but also the experimental measurement for validation of various aspects of the highly coupled problem. In this study, an attempt is made to identify suitable experimental data that could serve as a source for validation of material thermal response modeling tools. To reduce the computational complexity, this study focuses only on non-charring ablators, where the material thermal response could be modeled with a single governing equation for solid conduction and the ablation is limited only to the surface of the material. With a well characterized and publicly available experimental data being sparse, the study is limited in presenting test cases for only three materials: camphor, graphite and FiberForm® in the sequence of increased modeling complexity. Graphite is a commonly used TPS material for aerospace applications, both for leading edges of high-speed vehicles and internal insulation of solid rocket motors. FiberForm® is a porous carbon pre-form used in preparation of the well known PICA material Tran et al. [1996]. Inclusion of camphor into the list is conditioned with the relative simplicity in modeling the material thermal and chemical response and the low-enthalpy flow environment. In addition, camphor has been used as a simple test material for study of flow transition behavior by Stock and Ginoux [1973] and assessment of a heatshield shape change at flight relevant conditions by Rotondi et al. [2022]. In this work, the identified experimental data was extracted from the public literature and test cases that yet have been published. As it was found from the review, not a single test case contains an exhaustive set of data that would validate every aspect of the material physics. However, in the data collected, various aspects of the material behavior can be still validated, such as surface and in-depth temperature, amount of recession and a shape change. The identified experimental data for each case is accompanied with a characterized flow environment and simulated boundary conditions predicted by a Data-Parallel Line Relaxation (DPLR) code Wright et al. [1998]. In addition, material thermal response numerical simulations in each test case are performed with Kentucky Aerothermodynamics and Thermal Response System (KATS-MR) Zibitsker et al. [2022] providing a comparative study and a sanity check for the proposed validation data. Sample results from the performed numerical study are shown below. Figure 1 shows distribution of surface heat flux and pressure values on a hemi-cylinder model made of FiberForm® and tested in HyMETS arc-jet facility. The results are shown for the high pressure condition among the two tests. Flow simulation was performed with DPLR code on a quarter of original geometry. In the figure, the quarter shape was mirrored across zx and xy planes to show the complete distribution. Figure 2 shows the material response results for the high pressure case (7500 Pa), simulated with KATS-MR and a comparison to the experimental data for the surface temperature and shape shape. The simulation was performed on a 2-D slice, extracted in the xy plane at the middle of the sample. Figure 3 shows the material response simulation for the low pressure case (3500 Pa) and a comparison to the experimental data for surface temperature and shape change.

ablation↗

Flame Deflector Ablation Analysis based on Artemis 1 Launch Environment

This paper presents the updated ablative analysis methods used to determine Artemis 1 launch load environment on the flame deflector for the design based on Artemis I Assessments. The flame trench under Pad 39B at Kennedy Space Center contains a flame deflector to safely divert the exhaust plume from the SLS rocket during launch. During launch of Artemis I the refurbished flame trench and the new flame deflector experienced peak temperatures of over 2,000 degrees Fahrenheit (over 1,000 degrees Celsius) for several seconds. These extreme conditions caused ablation (material removal) from the steel plates. This paper contains flame deflector heat flux values for design based on Artemis I assessment. Post flight images of the flame deflector are shown along with “Pre vs Post” Flame Deflector scan image to measure the post flight deviations. Using COMSOL, a method to calculate a heat flux value due to measured deviations in the deflector plates caused by ablation is shown.

Artemis I↗

Bayesian Inference and the Effects of Varying Uncertainty Models in Charring Ablator Calibration and Uncertainty Quantification Problems

The Mars Science Laboratory (MSL) vehicle utilized a heat shield constructed from NASA’s Phenolic-Impregnated Carbon Ablator (PICA) material to protect the main structure from the high enthalpy environment encountered during hypersonic atmospheric entry. During the vehicle’s descent through Martian atmosphere, multiple thermocouples embedded within the heat shield captured in-depth material temperature data that allow for studies to be conducted on current material response reconstruction tools. In the present work, material temperature data obtained from thermocouples within the MISP-4 plug (MEDLI (Mars Science Laboratory Entry, Descent, and Landing Instrument) Integrated Sensor Plug) are utilized in the calibration of Theoretical Ablative Composite for Open Testing (TACOT) model parameters in conjunction with NASA’s Porous material Analysis Toolbox (PATO) through Bayesian inference where uncertainty due to parametric, modeling, and experimental sources is simultaneously quantified. Prior to the study, a sensitivity analysis is performed through computation of the robust Sobol indices in an effort to study the relationship between input space and model response and to reduce the dimensionality of the statistical inverse problem. The Bayesian inference methodology necessitates an a-priori choice to be made for the uncertainty model for which numerous possibilities are available. Across most works, however, only basic additive or multiplicative models are utilized with pre-defined magnitudes of uncertainty based on a-priori knowledge or to-be-calibrated multipliers of static covariance matrix structures. The present effort explores the effects of informed uncertainty models, ones with temporal dependence that are simultaneously calibrated through Bayesian inference, on calibrated results for parameters that make up the uncertain input space.

Sensitivity Analysis↗

Superselective Particle Embolization Enhances Efficacy of Radiofrequency Ablation: Effects of Particle Size and Sequence of Action

Purpose. To evaluate the effects of particle size and course of action of superselective bland transcatheter arterial embolization (TAE) on the efficacy of radiofrequency ablation (RFA). Methods. Twenty pigs were divided into five groups: group 1a, 40-{mu}m bland TAE before RFA; group 1b, 40-{mu}m bland TAE after RFA; group 2a, 250-{mu}m bland TAE before RFA; group 2b, 250-{mu}m bland TAE after RFA and group 3, RFA alone. A total of 40 treatments were performed with a combined CT and angiography system. The sizes of the treated zones were measured from contrast-enhanced CTs on days 1 and 28. Animals were humanely killed, and the treated zones were examined pathologically. Results. There were no complications during procedures and follow-up. The short-axis diameter of the ablation zone in group 1a (mean {+-} standard deviation, 3.19 {+-} 0.39 cm) was significantly larger than in group 1b (2.44 {+-} 0.52 cm; P = 0.021), group 2a (2.51 {+-} 0.32 cm; P = 0.048), group 2b (2.19 {+-} 0.44 cm; P = 0.02), and group 3 (1.91 {+-} 0.55 cm; P < 0.001). The greatest volume of ablation was achieved by performing embolization with 40-{mu}m particles before RFA (group 1a; 20.97 {+-} 9.65 cm{sup 3}). At histology, 40-{mu}m microspheres were observed to occlude smaller and more distal arteries than 250-{mu}m microspheres. Conclusion. Bland TAE is more effective before RFA than postablation embolization. The use of very small 40-{mu}m microspheres enhances the efficacy of RFA more than the use of larger particles.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Ablation and Oxidation Behaviors of SiC Coatings on Graphite Prepared by Slurry Sintering and Pack Cementation

SiC coatings were generated on graphite using slurry sintering (SS) and pack cementation (PC). The samples’ ablation features were assessed by an oxyacetylene torch. The rates of mass ablation of the PC–SiC and SS–SiC coatings were approximated 2.17 × 10{sup −3} and 9.52 × 10{sup −3} g s{sup −1}, respectively, decreased by 84.1 and 29.6% compared to the uncoated samples. It was mainly attributed to the formation of a SiO{sub 2} layer on the surface. The continuous SiO{sub 2} molten film formed via the PC–SiC oxidation generates a sealing mechanism which can be an obstacle against the oxygen diffusion and hinder more ablation. This is while discontinuous SiO{sub 2} film formed from the thin SS–SiC cannot protect the graphite effectively. The non-isothermal oxidation test shows that without the SiC coating, the sample weight is lost largely from 25 to 1500 °C, and its weight loss was 2.2% after the TGA. However, after coating, the samples possessed excellent oxidation protection and weight losses of SS–SiC and PC–SiC coatings are down to 1.3 and 0.6%, respectively. The more oxidation of the graphite substrate occurred due to the formation of macrocracks in the coating during the TGA and also the formation of holes on SiO{sub 2} glass layer owing to release of CO or CO{sub 2}.

36 MATERIALS SCIENCE↗

Fe-carbide/Fe-oxide-based nanocomposites synthesized as magnetic nanomaterials via laser ablation synthesis in solution (LASiS)

Magnetic nanostructured materials (MNMs) have gained prominence in materials technology developments owing to their potential biomedical applications for hyperthermia cancer treatment, and transplant organ cryopreservation. Herein, we report the facile and cost-effective synthesis of Fe-based composite MNMs, comprising both Fe@Fe 2 O 3 and Fe 3 C@C core-shell nanoparticles (NPs), via Laser Ablation Synthesis in Solution (LASiS) using Fe targets ablated under acetone and toluene. Detailed materials characterizations using electron microscopy-based imaging, diffraction studies, and spectroscopic analyses - including Raman and Mössbauer spectroscopy - relate the structure-composition properties for different Fe-oxide/carbide phases in the aforesaid MNMs to their respective magnetic responses. Specifically, we confirm the presence of ultra-small (2–10 nm) amorphous Fe-oxide NPs, as well as Fe@Fe 2 O 3 core-shell NPs (20–40 nm) in the samples synthesized by ablating Fe under acetone. In contrast, samples synthesized under toluene indicate a higher concentration of Fe 3 C@C core-shell NPs (20–40 nm) with a relatively low concentration of Fe 2 O 3 NPs (2–10 nm). Furthermore, the crystallinity of the metallic phases and carbonaceous shell coatings are systematically increased by carrying out LASiS under heated toluene (up to ~95 °C). Importantly, mössbauer spectroscopy results indicate that the elevation in toluene temperature leads to an increase in the concentrations of Fe 3 C@C NPs from ~40 % to ~53 % (at.).

36 MATERIALS SCIENCE↗

Universal Survival Curve and Single Fraction Equivalent Dose: Useful Tools in Understanding Potency of Ablative Radiotherapy

Purpose: Overprediction of the potency and toxicity of high-dose ablative radiotherapy such as stereotactic body radiotherapy (SBRT) by the linear quadratic (LQ) model led to many clinicians' hesitating to adopt this efficacious and well-tolerated therapeutic option. The aim of this study was to offer an alternative method of analyzing the effect of SBRT by constructing a universal survival curve (USC) that provides superior approximation of the experimentally measured survival curves in the ablative, high-dose range without losing the strengths of the LQ model around the shoulder. Methods and Materials: The USC was constructed by hybridizing two classic radiobiologic models: the LQ model and the multitarget model. We have assumed that the LQ model gives a good description for conventionally fractionated radiotherapy (CFRT) for the dose to the shoulder. For ablative doses beyond the shoulder, the survival curve is better described as a straight line as predicted by the multitarget model. The USC smoothly interpolates from a parabola predicted by the LQ model to the terminal asymptote of the multitarget model in the high-dose region. From the USC, we derived two equivalence functions, the biologically effective dose and the single fraction equivalent dose for both CFRT and SBRT. Results: The validity of the USC was tested by using previously published parameters of the LQ and multitarget models for non-small-cell lung cancer cell lines. A comparison of the goodness-of-fit of the LQ and USC models was made to a high-dose survival curve of the H460 non-small-cell lung cancer cell line. Conclusion: The USC can be used to compare the dose fractionation schemes of both CFRT and SBRT. The USC provides an empirically and a clinically well-justified rationale for SBRT while preserving the strengths of the LQ model for CFRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Definitive Management of Oligometastatic Melanoma in a Murine Model Using Combined Ablative Radiation Therapy and Viral Immunotherapy

Purpose: The oligometastatic state is an intermediate state between a malignancy that can be completely eradicated with conventional modalities and one in which a palliative approach is undertaken. Clinically, high rates of local tumor control are possible with stereotactic ablative radiation therapy (SABR), using precisely targeted, high-dose, low-fraction radiation therapy. However, in oligometastatic melanoma, virtually all patients develop progression systemically at sites not initially treated with ablative radiation therapy that cannot be managed with conventional chemotherapy and immunotherapy. We have demonstrated in mice that intravenous administration of vesicular stomatitis virus (VSV) expressing defined tumor-associated antigens (TAAs) generates systemic immune responses capable of clearing established tumors. Therefore, in the present preclinical study, we tested whether the combination of systemic VSV-mediated antigen delivery and SABR would be effective against oligometastatic disease. Methods and Materials: We generated a model of oligometastatic melanoma in C57BL/6 immunocompetent mice and then used a combination of SABR and systemically administered VSV-TAA viral immunotherapy to treat both local and systemic disease. Results: Our data showed that SABR generates excellent control or cure of local, clinically detectable, and accessible tumor through direct cell ablation. Also, the immunotherapeutic activity of systemically administered VSV-TAA generated T-cell responses that cleared subclinical metastatic tumors. We also showed that SABR induced weak T-cell-mediated tumor responses, which, particularly if boosted by VSV-TAA, might contribute to control of local and systemic disease. In addition, VSV-TAA therapy alone had significant effects on control of both local and metastatic tumors. Conclusions: We have shown in the present preliminary murine study using a single tumor model that this approach represents an effective, complementary combination therapy model that addresses the need for both systemic and local control in oligometastatic melanoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser Ablation-Capillary Absorption Spectroscopy: A novel approach for high throughput and increased spatial resolution measurements of δ 13 C in plant-soil systems

Spatial and temporal heterogeneity of nutrient exchange within the rhizosphere is a topic of increasing interest, although challenging to study due to limits in existing analytical capabilities. Here, we developed and demonstrated a new approach applying laser ablation sample introduction to capillary absorption spectroscopy (LA-CAS) to characterize carbon isotopic distribution within plant tissues, rhizosphere, and soil. We exposed switchgrass plants to 13 CO 2 to allow tracing of 13 C-labelled photosynthates within plant biomass and into the associated soil. The LA-CAS methods we describe leverage continuous measurements of a sample stream derived from laser ablation line scans (10-25 µm in width) over a sample surface which enables the user to produce an isotope map with a) higher data density or b) over larger spatial areas versus previously existing techniques. This versatility of LA-CAS is assessed through testing of a range of laser parameters (spot size, scan rates) on various materials (soil, plant biomass/tissues, and rhizosphere). Here, we demonstrate the ability of LA-CAS to provide near instantaneous $δ$ 13 C measurements over isotopically distinct surfaces to enable high spatially resolved mapping of 13 C-labelled material within the rhizosphere. Applying LA-CAS analysis to plant biomass, we observed higher $δ$ 13 C values concentrated within phloem structures, consistent with localized photosynthate transport. When mapping across the rhizosphere, 13 C-enriched soil was typically present within 5-10µm of root boundaries with a steep spatial increase in $δ$ 13 C when the scan approached the middle of the root. As with all LA approaches, care is required to ensure accurate results as phenomena linked to ablation, combustion, and isotopic measurement can impart artifacts if not carefully controlled. Still, taken as a whole, our demonstrations highlight the increased sample throughput, improved data density, and enhanced $δ$ 13 C capability of LA-CAS versus other LA techniques and emphasize the role this method can play in future plant and rhizosphere related studies.

59 BASIC BIOLOGICAL SCIENCES↗

Genetic ablation and short-duration inhibition of lipoxygenase results in increased macroautophagy

12/15-lipoxygenase (12/15-LOX) is involved in organelle homeostasis by degrading mitochondria in maturing red blood cells and by eliminating excess peroxisomes in liver. Furthermore, 12/15-LOX contributes to diseases by exacerbating oxidative stress-related injury, notably in stroke. Nonetheless, it is unclear what the consequences are of abolishing 12/15-LOX activity. Mice in which the alox15 gene has been ablated do not show an obvious phenotype, and LOX enzyme inhibition is not overtly detrimental. We show here that liver histology is also unremarkable. However, electron microscopy demonstrated that 12/15-LOX knockout surprisingly leads to increased macroautophagy in the liver. Not only macroautophagy but also mitophagy and pexophagy were increased in hepatocytes, which otherwise showed unaltered fine structure and organelle morphology. These findings were substantiated by immunofluorescence showing significantly increased number of LC3 puncta and by Western blotting demonstrating a significant increase for LC3-II protein in both liver and brain homogenates of 12/15-LOX knockout mice. Inhibition of 12/15-LOX activity by treatment with four structurally different inhibitors had similar effects in cultured HepG2 hepatoma cells and SH-SY5Y neuroblastoma cells with significantly increased autophagy discernable already after 2 hours. Hence, our study reveals a link between ablation or inhibition of 12/15-LOX and stimulation of macroautophagy. The enhanced macroautophagy may be related to the known tissue-protective effects of LOX ablation or inhibition under various diseased conditions caused by oxidative stress and ischemia. This could provide an important cleaning mechanism of cells and tissues to prevent accumulation of damaged mitochondria and other cellular components. - Highlights: • A relationship between lipoxygenases and autophagy is disclosed. • 12/15-lipoxygenase knockout increases autophagy in mice liver and brain. • Lipoxygenase inhibition boosts autophagy in human hepatoma and neuroblastoma cells. • Lipoxygenase knockout or inhibition triggers selective autophagy.

60 APPLIED LIFE SCIENCES↗

Measurements of the ablation-front trajectory and low-mode nonuniformity in direct-drive implosions using x-ray self-emission shadowgraphy

Self-emission x-ray shadowgraphy provides a method to measure the ablation-front trajectory and low-mode nonuniformity of a target imploded by directly illuminating a fusion capsule with laser beams. The technique uses time-resolved images of soft x-rays (> 1 keV) emitted from the coronal plasma of the target imaged onto an x-ray framing camera to determine the position of the ablation front. Methods used to accurately measure the ablation-front radius ( ${\it\delta}R=\pm 1.15~{\rm\mu}\text{m}$ ), image-to-image timing ( ${\it\delta}({\rm\Delta}t)=\pm 2.5$ ps) and absolute timing ( ${\it\delta}t=\pm 10$ ps) are presented. Angular averaging of the images provides an average radius measurement of ${\it\delta}(R_{\text{av}})=\pm 0.15~{\rm\mu}\text{m}$ and an error in velocity of ${\it\delta}V/V=\pm 3\%$ . This technique was applied on the Omega Laser Facility and the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrode Modification by Laser Ablation to Overcome Mechanical and Scalability Limitations of Solid-State Prealkylation of Electrode Architectures

In this work, laser ablation of Si electrode surfaces is utilized to provide localized strain relief during the Solid State Prealkylation of Electrode Architectures (SPEAR) process, in addition to volumetric expansion relief in the form of free volume channels across the electrode. A hexagonal mesh patterning was employed via laser ablation, where the hexagonal diameter (pitch) was varied from 250 to 1000 µm. It was demonstrated that these channels serve as expansion voids, accommodating the increase in electrode thickness observed during SPEAR and preventing cracking at the electrode surface. Optical microscopy and Raman mapping confirm that Li diffusion is the rate-limiting solid-state process, requiring a 24 h rest period to achieve homogeneous LixSi alloying through the electrode bulk. Electrochemical evaluations in full cells show that a 1000 μm pitch pattern yields a high initial discharge capacity of 2485 mA h g–1 and 86.4% capacity retention after 80 cycles, whereas smaller pitches (<500 μm) result in lithium plating at 4.1 V in full cells paired with NMC 811 due to excessive current collector exposure from the ablation process. XPS analysis reveals that the laser treatment modifies the electrode surface by increasing the Si–O and C–O species, changing the SEI composition observed via an increase in fluorophosphates upon cycling.

Musgrove, Amanda [ORNL] (ORCID:0009000220910389)↗

High speed direct imaging of thin metal film ablation by movie-mode dynamic transmission electron microscopy

Obliteration of matter by pulsed laser beams is not only prevalent in science fiction movies, but finds numerous technological applications ranging from additive manufacturing over machining of micro- and nanostructured features to health care. Pulse lengths ranging from femtoseconds to nanoseconds are utilized at varying laser beam energies and pulse lengths, and enable the removal of nanometric volumes of material. While the mechanisms for removal of material by laser irradiation, i.e., laser ablation, are well understood on the micrometer length scale, it was previously impossible to directly observe obliteration processes on smaller scales due to experimental limitations for the combination of nanometer spatial and nanosecond temporal resolution. Here, we report the direct observation of metal thin film ablation from a solid substrate through dynamic transmission electron microscopy. Quantitative analysis reveals liquid-phase dewetting of the thin-film, followed by hydrodynamic sputtering of nano- to submicron sized metal droplets. We discovered unexpected fracturing of the substrate due to evolving thermal stresses. This study confirms that hydrodynamic sputtering remains a valid mechanism for droplet expulsion on the nanoscale, while irradiation induced stress fields represent limit laser processing of nanostructured materials. Ultimately, our results allow for improved safety during laser ablation in manufacturing and medical applications.

36 MATERIALS SCIENCE↗

Femtosecond Laser Ablation Multicollector ICPMS Analysis of Uranium Isotopes in NIST Glass

We have utilized femtosecond laser ablation coupled to multi-collector inductively couple plasma mass spectrometry to measure the uranium isotopic content of NIST 61x (x=0,2,4,6) glasses. The uranium content of these glasses is a linear two-component mixing between isotopically natural uranium and the isotopically depleted spike used in preparing the glasses. Laser ablation results match extremely well, generally within a few ppm, with solution analysis following sample dissolution and chemical separation. In addition to isotopic data, sample utilization efficiency measurements indicate that over 1% of ablated uranium atoms reach a mass spectrometer detector, making this technique extremely efficient. Laser sampling also allows for spatial analysis and our data indicate that rare uranium concentration inhomogeneities exist in NIST 616 glass.

Duffin, Andrew M.↗