Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APERTURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Dynamic aperture studies for the LHC high luminosity lattice

Since quite some time, dynamic aperture studies have been undertaken with the aim of specifying the required field quality of the new magnets that will be installed in the LHC ring in the framework of the high-luminosity upgrade. In this paper the latest results concerning the specification work will be presented, taking into account both injection and collision energies and the field quality contribution from all the magnets in the newly designed interaction regions.

43 PARTICLE ACCELERATORS↗

SNM neutron detection using a time-gated synthetic aperture hybrid approach

This work focuses on using forward and adjoint transport in a hybrid application of 3-D deterministic (PENTRAN) and Monte Carlo (MCNP5) codes to model a series of neutron detector blocks. These blocks, or 'channels, ' contain a unique set of moderators with 4 atm He-3 detectors tuned to detect and profile a gross energy spectrum of a passing neutron (SNM) source. Ganging the units together as a large area system enables one to apply time gating the source-detector response to maximize signal to noise responses from a passing source with minimal background; multiple units may be positioned as a collective synthetic aperture detector array to be used as a way of performing real time neutron spectroscopy for detecting special nuclear materials in moving vehicles. The initial design, detector response coupling, confirmation of initial design functionality using adjoint transport calculations, and realistic simulation using PENTRAN and MCNP5 are presented. Future work will include optimization and application to realistic scenarios and additional sources. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and evaluation of a portable CZT coded aperture gamma-camera

We present the design and the evaluation of a CdZnTe (CZT) based gamma camera using a coded aperture mask. This camera, based on a 8 cm{sup 3} detection module, is small enough to be portable and battery-powered (4 kg weight and 4 W power dissipation). As the detector has spectral capabilities, the gamma camera allows isotope identification and colored imaging, by affecting one color channel to each identified isotope. As all data processing is done at real time, the user can directly observe the outcome of an acquisition and can immediately react to what he sees. We first present the architecture of the system, how the detector works, and its performances. After, we focus on the imaging technique used and its strengths and limitations. Finally, results concerning sensitivity, spatial resolution, field of view and multi-isotope imaging are shown and discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel synthetic aperture technique for breast tomography with toroidal arrays

Ultrasound is commonly used as an adjunct to mammography for diagnostic evaluation of suspicions arising from breast cancer screening. As an alternative to conventional sonography that uses hand-held transducers, toroidal array probes that encircle the breast immersed in a water bath have been investigated for ultrasound tomography. This paper introduces a new method for three-dimensional synthetic aperture diffraction tomography that maximizes the resolution in the scanning direction and provides quantitative reconstructions of the acoustic properties of the object. The method is validated by means of numerical simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combining Measurements with Three-Dimensional Laser Scanning System and Coded Aperture Gamma-Ray Imaging Systems for International Safeguards Applications

Being able to verify the operator's declaration in regards to technical design of nuclear facilities is an important aspect of every safeguards approach. In addition to visual observation, it is relevant to know if nuclear material is present or has been present in piping and ducts not declared. The possibility of combining different measurement techniques into one tool should optimize the inspection effort and increase safeguards effectiveness. Oak Ridge National Laboratory (ORNL) is engaged in a technical collaboration project involving two U.S. Department of Energy foreign partners to investigate combining measurements from a three-dimensional (3D) laser scanning system and gamma-ray imaging systems. ORNL conducted simultaneous measurements with a coded-aperture gamma-ray imager and the 3D laser scanner in an operational facility with complex configuration and different enrichment levels and quantities of uranium. This paper describes these measurements and their results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamic aperture and space charge effect studies for the Recycler ring for Project-X

A simplified Recycler lattice was created to fine tune injection straight, ring tune, and phase trombone. In this paper, we will present detailed modifications for further optimization of Recycler lattice which requires the investigation of tune footprint and dynamic aperture based on higher order momentum components of the magnetic fields, together with the space charge effects.

43 PARTICLE ACCELERATORS↗

Combining Measurements with Three-Dimensional Laser Scanning System and Coded Aperture Gamma-Ray Imaging System for International Safeguards Applications

Being able to verify the operator's declaration in regard to the technical design of nuclear facilities is an important aspect of every safeguards approach. In addition to visual observation, it is necessary to know if nuclear material is present or has been present in undeclared piping and ducts. The possibility of combining the results from different measurement techniques into one easily interpreted product should optimize the inspection effort and increase safeguards effectiveness. A collaborative effort to investigate the possibility of combining measurements from a three-dimensional (3D) laser scanning system and gamma-ray imaging systems is under way. The feasibility of the concept has been previously proven with different laboratory prototypes of gamma-ray imaging systems. Recently, simultaneous measurements were conducted with a new highly portable, mechanically cooled, High Purity Germanium (HPGe), coded-aperture gamma-ray imager and a 3D laser scanner in an operational facility with complex configuration and different enrichment levels and quantities of uranium. With specially designed software, data from both instruments were combined and a 3D model of the facility was generated that also identified locations of radioactive sources. This paper provides an overview of the technology, describes the measurements, discusses the various safeguards scenarios addressed, and presents results of experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of a Variable-Aperture Full-Ring SPECT System using Large-Area Pixelated CZT Modules: A Simulation Study for Brain SPECT Applications

Single photon emission computed tomography (SPECT) scanner using cadmium zinc telluride (CZT) offers improved imaging capability over conventional NaI (Tl)-based SPECT scanner. We aim to demonstrate a full-ring SPECT system design with eight large-area CZT detectors that can be used for a broad spectrum of SPECT radiopharmaceuticals and provides higher sensitivity and better spatial resolution than those of conventional NaI (Tl)-based gamma cameras. A newly-designed full-ring SPECT system is composed of 8 large-area CZT cameras (128 mm × 179.2 mm effective area) that can be independently swiveled around their own axes of rotation independently and can have radial motion for varying aperture sizes that can be adapted to different sizes of imaging volume. Extended projection data were generated by conjoining projections of two adjacent detectors to overcome the limited field-of-view (FOV) by each CZT camera. Using Monte Carlo simulations, we evaluated this new system design with digital phantoms including a Derenzo hot-rod phantom and a Zubal brain phantom. Comparison of performance metrics such as spatial resolution, sensitivity, contrast-to-noise ratio (CNR), and contrast-recovery ratio were made between our design and a conventional SPECT scanner. The proposed scanner could result in up to about 3 times faster in acquisition time over conventional scan time at same acquisition time per step. The spatial resolution of our proposed scanner was similar or better to that of the conventional scanner, and there was significant performance improvement over the conventional scanner particularly in sensitivity (approximately 4 times). Overall, we successfully reconstructed the phantom image for both 99 mTc-based perfusion and 123 I-based dopamine transporter (DaT) brain studies simulated for our new design. In particular, the striatal/background contrast-recovery ratio in 3-to-1 reference ratio was over the 0.8 for the 123 I-based DaT study. In conclusion, we demonstrated the potential of our new full-ring CZT SPECT design, showing improved performance metrics such as improved system sensitivity and CNR while maintaining other important imaging parameters such as spatial resolution.

36 MATERIALS SCIENCE↗

High-resolution fully-polarimetric synthetic aperture radar dataset

Fully-polarimetric synthetic aperture radar (PolSAR) data contain a rich body of elementary scattering physics information that is critically valuable for a broad range of applications and scientific purposes. However, there is a lack of available high-resolution (< 0.3048-m) data available for PolSAR phenomenology research. This article introduces a high-resolution PolSAR data set collected and provided by Sandia National Laboratories (SNL). The data sets were collected to support studying high-resolution scattering physics from different types of clutter and applications such as polarimetric-based terrain classification.

West, Roger Derek↗

Informed unsupervised machine learning analysis of dislocation microstructure from high-resolution differential aperture X-ray structural microscopy data

This study leverages high-resolution differential-aperture X-ray structural microscopy (DAXM) to probe the local dislocation structure in deformed 304L-stainless steel at small strain, by measuring the lattice rotation and deviatoric elastic strain with a sub-micron resolution. For a single grain in a polycrystalline specimen, the measured lattice rotation field over the measured volume exhibited a multimodal distribution while the deviatoric elastic strain showed a single-mode distribution. An unsupervised Cauchy mixture machine learning model was developed to resolve the multimodal distribution of the lattice rotation. By mapping the lattice rotation data associated with each Cauchy peak in the model back onto the measured volume, we identify contiguous regions of the crystal rotated near the average values corresponding to the peaks of the overall rotation distribution. These regions represent the grain subdivision in the microstructure. Finally, the dislocation density tensor was also computed and its norm was laid over the rotation field to detect the subgrain boundaries. This step provided a validation of the Cauchy mixture model for the analysis of the lattice rotation distribution. The current study highlights the integration of advanced X-ray microscopy techniques with data-driven analysis methods to uncover detailed microstructure scales in deformed crystals.

Machine learning; Lattice rotation; High-energy X-↗

First Clinical Release of an Online, Adaptive, Aperture-Based Image-Guided Radiotherapy Strategy in Intensity-Modulated Radiotherapy to Correct for Inter- and Intrafractional Rotations of the Prostate

Purpose: We developed and evaluated a correction strategy for prostate rotations using direct adaptation of segments in intensity-modulated radiotherapy (IMRT). Method and Materials: Implanted fiducials (four gold markers) were used to determine interfractional translations, rotations, and dilations of the prostate. We used hybrid imaging: The markers were automatically detected in two pretreatment planar X-ray projections; their actual position in three-dimensional space was reconstructed from these images at first. The structure set comprising prostate, seminal vesicles, and adjacent rectum wall was transformed accordingly in 6 degrees of freedom. Shapes of IMRT segments were geometrically adapted in a class solution forward-planning approach, derived within seconds on-site and treated immediately. Intrafractional movements were followed in MV electronic portal images captured on the fly. Results: In 31 of 39 patients, for 833 of 1013 fractions (supine, flat couch, knee support, comfortably full bladder, empty rectum, no intraprostatic marker migrations >2 mm of more than one marker), the online aperture adaptation allowed safe reduction of margins clinical target volume-planning target volume (prostate) down to 5 mm when only interfractional corrections were applied: Dominant L-R rotations were found to be 5.3 Degree-Sign (mean of means), standard deviation of means {+-}4.9 Degree-Sign , maximum at 30.7 Degree-Sign . Three-dimensional vector translations relative to skin markings were 9.3 {+-} 4.4 mm (maximum, 23.6 mm). Intrafractional movements in 7.7 {+-} 1.5 min (maximum, 15.1 min) between kV imaging and last beam's electronic portal images showed further L-R rotations of 2.5 Degree-Sign {+-} 2.3 Degree-Sign (maximum, 26.9 Degree-Sign ), and three-dimensional vector translations of 3.0 {+-}3.7 mm (maximum, 10.2 mm). Addressing intrafractional errors could further reduce margins to 3 mm. Conclusion: We demonstrated the clinical feasibility of an online adaptive image-guided, intensity-modulated prostate protocol on a standard linear accelerator to correct 6 degrees of freedom of internal organ motion, allowing safe and straightforward implementation of margin reduction and dose escalation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of the dislocation activity in a Mg–Y alloy by differential aperture X-ray microscopy

Differential aperture X-ray microscopy (DAXM) was employed in this study to reveal the development of geometrically necessary dislocations (GNDs) when a Mg-5 wt% Y alloy is subjected to bending. The characters of the GNDs were determined from the streak direction of the diffraction peaks. Five grains were analyzed voxel by voxel for the GND content. Among those voxels with peak streaking, 77% contain basal or non-basal < a > GNDs, while the other 23% contain < c + a > GNDs. Furthermore, those < c + a > dislocations were nucleated to accommodate local stress concentration. Even though < c + a > dislocations are less mobile, they make important contribution to the high ductility of Mg-Y alloys.

36 MATERIALS SCIENCE↗

Bridgman growth of large-aperture yttrium calcium oxyborate crystal

Highlights: ► YCOB is a novel non-linear optical crystal possessing good thermal, mechanical and nonlinear optical properties. ► Large size crystal growth is key technology question for YCOB crystal. ► YCOB crystals 3 in. in diameter were grown with modified vertical Bridgman method. ► It is a more effective growth method to obtain large size and high quality YCOB crystal. -- Abstract: Large-aperture yttrium calcium oxyborate YCa{sub 4}O(BO{sub 3}){sub 3} (YCOB) crystals with 3 in. in diameter were grown with modified vertical Bridgman method, and the large crystal plate (63 mm × 68 mm × 20 mm) was harvested for high-average power frequency conversion system. The crack, facet growth and spiral growth can be effectively controlled in the as-grown crystal, and Bridgman method displays more effective in obtain large size and high quality YCOB crystal plate than Czochralski technique.

36 MATERIALS SCIENCE↗

Focus optimization at relativistic intensity with high numerical aperture and adaptive optics

Improved focusing of laser beams using high numerical aperture systems is an efficient route to increasing intensities in the ultrafast regime to relativistic levels. We experimentally demonstrate a new method of optimizing the focus of a high-power laser, using second harmonic generation at full intensity in a low-pressure gas to provide a figure of merit for optimizing the shape of a deformable mirror via a genetic algorithm. Nonlinear and thermal aberrations are corrected, and aberrations introduced by filters are avoided. Furthermore, the method is applied to focus a millijoule, short pulse (30 fs), high repetition rate laser system to relativistic intensity in both near IR and mid IR regimes.

Lin, Jinpu↗

Rain footprints on C-band synthetic aperture radar images of the ocean - Revisited

It is well known that rain leaves footprints on the sea surface that sometimes become visible on synthetic aperture radar (SAR) images. Rain cells can easily be detected on SAR images at all radar frequencies when they are associated with a downdraft pattern. But rain cells are not always associated with downdraft and rain can also occur in other forms, as stratified rain, rain bands, and squall lines. It turns out that radar signatures of rain at C-band are much more complex than at L- or X-band radar and that it is particularly difficult to identify unambiguously rain events on C-band SAR images acquired over the ocean. This is because C-band lies in the transition region where raindrops impinging onto the sea surface can increase (usually) or decrease the backscattered radar power and where volume scattering and attenuation by rain drops in the atmosphere are not always negligible (at very high rain rates). In order to get an insight into the physical mechanisms causing the C-band radar signatures of rain, we first revisit results obtained from historic laboratory and field experiments and multi-frequency/multi-polarization SAR data acquired during the SIR-C/X-SAR spaceshuttle mission in 1994. Then we analyze several C-band SAR images acquired by the European satellites Envisat and Sentinel-1A, and the Canadian satellite Radarsat-2 and compare them, whenever possible, with quasi-coincident and collocated weather radar images. The observational data show that, at low to medium rain rates, the main physical mechanism causing C-band radar signatures of rain is Bragg scattering at ring waves generated by the rain drops impinging onto the sea surface, which increase the radar backscatter. However, areas of increased radar backscatter are often accompanied by adjacent areas of decreased radar backscatter, which is due to attenuation of the Bragg waves by turbulence also generated by the impinging rain drops. Furthermore, we present a full-polarimetric Radarsat-2 SAR image of a rain cell together with a polarimetric decomposition analysis, which shows that the C-band radar signature of a rain cell is caused by surface scattering. The observation show that radar signatures of rain cells often contain segments, where the co-polarized as well the cross-polarized radar backscatter are strongly enhanced, which indicates non-Bragg scattering contributions to the scattering process. Furthermore, the polarimetric decomposition analysis shows that the C-band radar signature of a rain cell is dominated by surface scattering. Possible mechanisms, like scattering at splash products, are discussed. Whether the normalized radar cross section (NRCS) due to rain is increased or decreased depends on rain rate, wind speed, incidence angle, and history of the rain event. At low to moderate wind speeds (< 10 ms - 1 ) and low to medium high rain rates (< 50 mm h - 1 ), the NRCS is usually increased by up to 8 dB, and at high wind speeds (> 10 m s - 1 ) and low to high rain rates (but < 50 mm h - 1 ), the NRCS is usually decreased by up to 3 dB.

54 ENVIRONMENTAL SCIENCES↗

Aperture‐Synthesis Radar Imaging With Compressive Sensing for Ionospheric Research

Abstract Inverse methods involving compressive sensing are tested in the application of two‐dimensional aperture‐synthesis imaging of radar backscatter from field‐aligned plasma density irregularities in the ionosphere. We consider basis pursuit denoising, implemented with the fast iterative shrinkage thresholding algorithm, and orthogonal matching pursuit (OMP) with a wavelet basis in the evaluation. These methods are compared with two more conventional optimization methods rooted in entropy maximization (MaxENT) and adaptive beamforming (linearly constrained minimum variance or often “Capon's Method.”) Synthetic data corresponding to an extended ionospheric radar target are considered. We find that MaxENT outperforms the other methods in terms of its ability to recover imagery of an extended target with broad dynamic range. Fast iterative shrinkage thresholding algorithm performs reasonably well but does not reproduce the full dynamic range of the target. It is also the most computationally expensive of the methods tested. OMP is very fast computationally but prone to a high degree of clutter in this application. We also point out that the formulation of MaxENT used here is very similar to OMP in some respects, the difference being that the former reconstructs the logarithm of the image rather than the image itself from basis vectors extracted from the observation matrix. MaxENT could in that regard be considered a form of compressive sensing.

Hysell, D. L.↗

Sensitivity of back‐projection algorithm (BPA) synthetic aperture radar (SAR) image formation to initial position, velocity, and attitude navigation errors

Abstract The Back‐Projection Algorithm (BPA) is a time‐domain‐matched filtering technique to form synthetic aperture radar (SAR) images. To produce high‐quality BPA images, precise navigation data for the radar platform must be known. Errors in position, velocity, or attitude result in improperly formed images that are corrupted by shifting and blurring. The contribution of this paper is the development of analytical expressions that characterise the relationship between navigation errors and image formation errors from an inertial navigation point of view, where trajectory estimation errors in position, velocity, and attitude propagate through time and cause compounding errors in the vehicle state vector. These analytical expressions are verified via simulated image formation and real‐data image formation.

Lindstrom, Colton↗

Alignment effects on a neutron imaging system using coded apertures

A high resolution neutron imaging system is being developed and tested on the OMEGA laser facility for inertial confinement fusion experiments. This diagnostic uses a coded imaging technique with a penumbral or an annular aperture. The sensitiveness of these techniques to misalignment was pointed out with both experiments and simulations. Results obtained during OMEGA shots are in good agreement with calculations performed with the Monte Carlo code GEANT4. Both techniques are sensitive to the relative position of the source in the field of view. The penumbral imaging technique then demonstrates to be less sensitive to misalignment compared to the ring. These results show the necessity to develop a neutron imaging diagnostic for megajoule class lasers taking into account our alignment capabilities on such facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗