Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wind energy generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

ECP Report: Update on Proxy Applications and Vendor Interactions

The ExaLearn miniGAN team (Ellis and Rajamanickam) have released miniGAN, a generative adversarial network(GAN) proxy application, through the ECP proxy application suite. miniGAN is the first machine learning proxy application in the suite (note: the ECP CANDLE project did previously release some benchmarks) and models the performance for training generator and discriminator networks. The GAN's generator and discriminator generate plausible 2D/3D maps and identify fake maps, respectively. miniGAN aims to be a proxy application for related applications in cosmology (CosmoFlow, ExaGAN) and wind energy (ExaWind). miniGAN has been developed so that optimized mathematical kernels (e.g., kernels provided by Kokkos Kernels) can be plugged into to the proxy application to explore potential performance improvements. miniGAN has been released as open source software and is available through the ECP proxy application website (https://proxyapps.exascaleproject.ordecp-proxy-appssuite/) and on GitHub (https://github.com/SandiaMLMiniApps/miniGAN). As part of this release, a generator is provided to generate a data set (series of images) that are inputs to the proxy application.

97 MATHEMATICS AND COMPUTING↗

Robust Scheduling of Microgrids Considering Unintentional Islanding Conditions

This paper proposes a robust scheduling model for microgrids considering the stochastic unintentional islanding conditions. The proposed model minimizes the total operating cost of the microgrid by efficiently coordinating the supply of power from local distributed energy resources and the main grid. To capture the prevailing uncertainties in renewable generation and demand as well as unintentional islanding conditions, a two-stage adaptive robust optimization model is formulated to minimize the total operating cost under the worst realization of the modeled uncertainties. The column and constraint generation (C&CG) method is used to solve the problem in an iterative manner. The solution of the proposed scheduling model ensures robust microgrid operation in consideration of all possible realization of renewable generation, demand and unintentional islanding condition. Numerical simulations on a microgrid consisting of a wind turbine, a PV panel, a fuel cell, two micro-turbines, a diesel generator and a battery demonstrate the effectiveness of the proposed approach.

Liu, Guodong↗

Comparison of wind-farm control strategies under realistic offshore wind conditions: wake quantities of interest

Wind-farm control strategies aim to increase the efficiency, and therefore lower the levelized cost of energy, of wind farms. This is done by using turbine settings such as the yaw angle, blade pitch angles, or generator torque to manipulate the wake that negatively affects downstream turbines in the farm. Two inherently different wind-farm control methods have been identified in the literature: wake steering (WS) and active wake mixing (AWM). As one of two companion papers focused on understanding practical aspects of these two wind-farm control strategies using large-eddy simulation (LES), we below analyze the wake quantities of interest for a single wind turbine performing WS and AWM, while the companion article (Frederik et al., 2025) focuses on turbine quantities of interest including power and structural loads for the same computational setup and also includes two-turbine arrays with full and partial wake overlap. The simulations, which are based in the LES solver AMR-Wind, are tailored to have inflow conditions representative of measurements from a site off the East Coast of the US, including with strong veer and low turbulence. The turbine, which is modeled in OpenFAST and coupled to the LES, is the IEA 15 MW, an open-source offshore design. After presenting an overview of the wake recovery for the different wake-control cases, the analysis probes the fluid-dynamic causes for the different performance of the arrays reported in the companion article by examining control volumes around the wakes and the budget of the mean-flow kinetic energy (MKE) within these volumes. In the high veer environment considered, the MKE recovery is dominated by mean convection, and this is shown to especially benefit the WS strategy when a neighboring turbine is directly downstream: there is ≈65 % more available power for a downstream turbine than in the baseline case, and this power is gained primarily through mean convection on the left-tip and top-tip faces of the control volume. However, the case with imperfect knowledge of the exact wind direction favors the pulse-type AWM strategy, largely because of ≈9 % increased turbulent entrainment from aloft versus the baseline that could be related to an apparent resistance to skewing in the pulsed wake. The general reduced effectiveness of helix-type and other individual-pitch-based AWM strategies for inflow with high veer and low turbulence as reported in the companion paper is due, in part, to low magnitudes of phase-averaged turbulent entrainment. Two main findings of this study are thus that veer has a significant impact on the effectiveness of different wake-control strategies and that pulse-type AWM may be a useful strategy when the objective is power maximization in realistic, offshore flow environments with imperfect knowledge of the exact wake overlap position on the downstream turbine.

17 WIND ENERGY↗

Chapter 38: Aerodynamics of Wake Steering

This chapter discusses the mechanisms that enable wake steering within a wind farm with a focus on wake steering performed using yaw misaligned turbines as this is the most popular approach to wake steering, although there are others. Wake steering is a type of wind farm control in which wind turbines in a wind farm operate with an intentional yaw misalignment to mitigate the effects of its wake on downstream turbines in order to increase overall combined wind farm energy production. This chapter goes into detail regarding the dominant aerodynamic characteristics that are present when a turbine operates in yaw misaligned conditions and suggests analytical models that can capture these effects. A detailed analysis of large-scale flow structures generated in wind farm control through yaw misalignment is presented. A collection of counter-rotating vortices, produced from a misaligned turbine, deforms the shape of the wake and produces asymmetric effects with oppositely signed yaw angles. These vortices generated by an upstream misaligned turbine can also deflect wakes of downstream non-misaligned turbines. This chapter also addresses the importance of modeling these counter-rotating vortices in analytical models for wind farm control design and for accurately quantifying the impacts of wake steering on gains in power production in larger wind farms.

modeling↗

Validating Greater Sage-Grouse Individual-based Model (IBM) Tool (Final Report)

The project focused on validating the previously developed Greater Sage-Grouse Individual-based Model (GrSG IBM; LaGory et al. 2012, 2021). The objective was to transform this predictive, spatially and temporally explicit model into a portable resource to assist siting/resource managers in proactively assessing the cumulative impacts of wind energy development on the greater sage-grouse. Utilizing a bottom-up, individual-based approach, the GrSG IBM accounts for landscape context and species behavior, aiming to reduce uncertainty in estimating development impacts and support ecologically mindful land-based wind energy development. The validation effort covered approximately 6,540 km 2 near the Seven Mile Hill Wind Project in Wyoming. The GrSG IBM tool, built on the NetLogo platform (Tisue and Wilensky 2004), was executed over a 50-year period, with the analysis focusing on years following a 10-year initialization phase. Key results demonstrated the tool’s biological soundness across five key biological metrics: non-chick age class distribution (older than 10 weeks), adult sex ratio, life expectancy, population size, and overall population growth. For instance, the tool estimated that 58.6% of the non-chick population was reproductively immature, while the reference ranges from 51.4% to 57.8% (Patterson 1952, Rogers 1964). Experts confirmed the tool’s estimate was within a reasonable range for the species. The tool estimated average life expectancy of 1.43 years, while the reference ranges from 0.9 years to 1.1 years (Ammann 1957, Hamerstrom 1949). Experts also supported the model’s life-expectancy estimate as ecologically sound for the species in the study area. In terms of population change, the model estimated an annual shift between a 0.6% decline and a 1.0% increase over 50 years. While the reference suggests 2.9% annual decline in range-wide populations (Cortes et al. 2023), that includes many at-risk populations in South Dakota and Washington, for example. Our study area—in the northeastern part of Carbon County and western-edge of Albany County, Wyoming—is one of the remaining greater sage-grouse habitats supporting some of the most stable populations. Experts confirmed that the range of the annual population change spanning from a 0.6% decline to a 1.0% increase estimated by the tool was reasonable for our study area for this reason and confirmed that aligned with population estimates from existing studies on the greater sage-grouse and wind energy development in the study area (LeBeau et al. 2017a, Smith et al. 2024). Furthermore, the project showed that temporally explicit biological metrics generated by the GrSG IBM tool can complement the USGS’ Prioritizing Restoration of Sagebrush Ecosystems Tool (PReSET; Duchardt et al. 2021) by incorporating habitat restoration strategies into seasonal habitat suitability models to visualize population responses over time.

17 WIND ENERGY↗

Navigating the Use of Direct Current in Residential Settings: Merits and Obstacles

This review paper provides an in-depth analysis of the role of Direct Current (DC) power systems in residential settings, focusing on their safety, efficiency, and environmental advantages. It recognizes the significant contribution of the residential sector to global carbon dioxide emissions and explores how DC power systems can help mitigate these effects. The paper traces the historical evolution of DC power, its resurgence with renewable energy technologies, and the advancements in power electronics that facilitate its integration. Emphasizing the efficiency and safety benefits, especially in low-voltage applications, the paper highlights the seamless integration of DC systems with inherently DC-generating renewable sources like solar PV and wind. The review discusses the critical role of converter technologies in the transition to DC power and examines the compatibility of DC systems with energy storage solutions, underscoring their potential for enhanced energy management. It also addresses the environmental impacts of adopting DC power, aligning with global carbon reduction efforts. The paper analyzes regional case studies, exploring practical applications and outcomes, and addresses challenges such as the need for standardization. It concludes with recommendations for stakeholders and future research directions, emphasizing the economic, technological, and environmental aspects of DC power systems. Overall, the paper presents DC power as a viable and sustainable option for residential energy conservation, contingent upon ongoing technological progress, supportive policies, and standardization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen Carriers for Renewable Microgrid System Applications

Utility-scale energy storage can help improve grid reliability, reduce costs, and promote faster adoption of intermittent sources such as solar and wind. This paper analyzes the technical aspects and economics of standalone microgrids operating on intermittent power combined with hydrogen energy storage. It explores the feasibility of using dibenzyltoluene (DBT) as a liquid organic hydrogen carrier to absorb excess energy during periods of high supply and polymer electrolyte fuel cells to generate electrical energy during periods of low supply. A comparative analysis is conducted on three power demand scenarios (industrial, residential, and office), in conjunction with three alternative energy sources: solar, wind and wind–solar mix. A mixed system of solar and wind energy can maintain an annual average efficiency above 70%, except for residential power demand, which lowered the efficiency to 67%. A balanced combination of wind and solar power was the most cost-effective option. The current levelized cost of electricity (LCOE) for industrial power demand was estimated to 15 ¢/kWh, and it is projected to decrease to 9 ¢/kWh in the future. For residential power demand, the LCOE was 45% higher due to the demand profile. In comparison, battery storage is significantly more expensive than hydrogen storage, even with future cost projections, increasing the LCOE between 60 and 120 ¢/kWh.

PEM electrolysis↗

Type 5 Wind Turbine Technology: How Synchronised, Synchronous Generation Avoids Uncertainties About Inverter Interoperability under IEEE 2800:2022

Degradation of system strength because of inverter-based resources (IBRs) is a major concern facing the zero-carbon transition. A new standard released this year, IEEE Standard 2800, attempts to codify the relationship between IBRs and the Transmission System Operator (TSO). It is apparent from IEEE 2800:2022 that there remain fundamental problems with quantifying whether source impedance (the measure of "system strength" with which the standard is concerned) will present a problem for allowing an IBR to connect. This is "because of complex interdependencies between IBR and power system characteristics". So developers are increasingly required to adopt mitigation options such as adding synchronous condensers or curtailing IBRs. A proven Type 5 (synchronous) wind turbine exists and has been running at 0.5 MW scale in a 46 MW wind farm in New Zealand since 2006 and eight turbines in Scotland since 2013. The US National Renewable Energy Laboratory (NREL) is conducting a study of the impacts on grid reliability, stability, and resilience of Type 5 wind turbines. The project has both simulation and testing tasks and will result in proposing a variable generation solution that will help system operators and utilities address all reliability and most resilience challenges in the evolving grid.

grid stability↗

Evolution of Scenario Generation Capabilities in the ExaSGD Project

High-fidelity renewable energy scenarios and rare-event high-impact contingencies are essential for modeling operations and infrastructure expansion of the next generation power grids using exascale computing resources. As the ExaSGD project progressed, our capabilities for generating scenarios for modeling wind power output at multiple wind farms significantly improved, evolving from the use of independent random perturbations to importance sampling-based techniques capturing representative spatial-temporal relations. Contingency generation also improved, evolving from standard N-1 techniques to probabilistic models of infrastructure damage resulting from extreme weather events. We review the developments in the realistic intermittent-energy scenario forecasting and extreme-event contingency creation as the ExaSGD project progressed and discuss the future work in these areas.

economic dispatch↗

Storage Enabled Flexibility of Conventional Generation Assets (StorFlex)

The power systems have faced progressively more demanding operational requirements over the last two decades. Several factors contribute to these challenging operating conditions, including load growth, aging infrastructure, increasing penetrations of distributed energy resources (DERs), electrification of the economy, and policy initiatives such as decarbonization. The power system and its components must provide high operational flexibility to mitigate these challenges. For example, the proliferation of intermittent DERs such as wind and solar has increased the need for conventional generation assets like hydropower plants to respond to sudden load-generation imbalances. The higher flexibility requirements for hydropower plants cause more wear and tear, potentially shortening the useful lifespan of hydropower turbines. To reduce the need for hydropower plants to follow sudden changes in the dispatch signal, we investigate their combined operation with the energy storage systems (ESSs; “ESS-based hybridization”). Our analyses focuses on improving the lifespan of hydropower plants through ESS-based hybridization. Wear and tear on hydropower turbines (particularly Francis turbines) is modeled using a loss-of-life concept that is based on damage experienced by the turbine due to various cycles of operation. Then, we show that using ESSs to offset some of the high variation increases the remaining life of the hydropower plants. To demonstrate this, a few modeling tools were developed for this work: (1) a dynamic model for various components of the turbine and its governor; (2) a control strategy that assigns a slow-varying dispatch signal to a hydropower unit versus a fastmoving signal to ESS, such that the overall power request remains the same; and (3) models for the financial analysis to quantify the economic merits of such a framework. We used the models we developed to analyze the dispatch pattern of an actual hydropower plant with a power output of 50 MW and a head height of 152 m. This work showed that ESS-based hybridization could extend the life of the hydropower plant by 5% on average. This extension in life was then used to estimate the economic benefit in terms of cost deferrals associated with hydropower plant maintenance and replacement: on average, $3.6 million. Sensitivity analysis with respect to the size of ESS and cost of turbines was performed to show the variation in benefits over the range of turbine costs and ESS sizes. Crucially, stacking damage reduction and lifetime extension with other ESS value streams such as providing ancillary services could substantially increase the financial benefits of ESS-based hybridization. The higher costs associated with ESS of appropriate size would make more financial sense when multiple value streams are stacked and co-optimized to extract the maximum benefit. This dimension will be explored in future work.

13 HYDRO ENERGY↗

A heuristic tool to assess regional impacts of renewable energy infrastructure on conservation areas

Wind and hydropower are important renewable components of national energy portfolios, but their infrastructure negatively affects biodiversity. Regional development requires identification of scenarios that minimize the cumulative impacts of multiple facilities. We introduce the cumulative impact plot (CIP) to quantify cumulative impacts of renewable energy development within a region. Summed impacts of facilities are plotted as a function of the number of facilities, with facilities ranked by increasing (the best-case scenario) or decreasing (worst-case scenario) individual impact. These curves represent lower and upper bounds to which alternative development scenarios (e.g., facilities ranked by generating capacity) can be compared. We used CIPs to assess overlap of potential wind and hydropower facilities with two types of conservation area in the United States: (1) federally protected lands and (2) critical habitats of federally threatened and endangered species. Here, we evaluated two alternative scenarios: facilities ranked by (A) decreasing generating capacity and (B) increasing distance from urban centers. Differences between the best-case and worst-case scenarios were large, thus revealing opportunities to develop facilities with limited impact on conservation areas. Alternative scenarios maximizing energy density generally resulted in conservation area overlap intermediate to best-case and worst-case scenarios. CIPs can also identify the proportion of wind versus hydropower favored under alternative scenarios. Build-out scenarios aimed at minimizing conservation area overlap favor hydropower, whereas alternative scenarios favor wind power. We conclude that CIPs can (1) complement—but should not replace—project-level environmental impact assessment, (2) integrate strategic, cumulative, and scenario-based assessments, and (3) harness rapidly growing geospatial data.

54 ENVIRONMENTAL SCIENCES↗

A Data-Driven Multi-Period Importance Sampling Strategy for Stochastic Economic Dispatch

Power systems with high penetrations of renewable energy (e.g., wind power) require sophisticated approaches to optimize system performance due to uncertainty in short-term system generation capacity. In this paper, we combine a data-driven analog scenario selection method with importance sampling to create a novel scenario construction approach for two-stage stochastic economic dispatch problems with a large number of wind farms on a network. The proposed method produces scenarios with realistic physics by finding high-fidelity analogs that can describe future states of the system. We show how to extend this method to multi-period operations and demonstrate the effectiveness of this technique by simulating economic dispatch operations on a synthetic test system over the course of a week.

data-driven forecasting↗

Characterization and repair of core gap manufacturing defects for wind turbine blades

Various wind turbine blade components, such as shear webs and skins, commonly use fiber-reinforced composite sandwich structures with a core material like balsa or foam. During manufacturing, core gap defects may result from the misalignment of adjacent foam or balsa core sheets in the blade mold. It is important to understand the influence that core gaps have on the structural integrity of wind turbine blades and how to mitigate their influence. This research characterized the effects of core gap defects at the manufacturing and mechanical levels for both epoxy and next-generation thermoplastic composites. Common repair methods were assessed and compared. Multiple defect sizes were compared using temperature data gathered with thermocouples embedded during manufacturing to core gap defect characteristics obtained using image-mapping techniques, optical microscopy, and mechanical characterization by long beam flexure. Results showed that peak exothermic temperatures during curing were closely related to core gap size. The long beam flexure tests determined that transverse core gaps under pure bending loads can have a substantial effect on the ultimate facesheet strength of both epoxy and thermoplastic composite sandwich structures (up to 25% strength reduction), although the size of the defect itself had less of an influence on the magnitude of the strength reduction. The supporting image-mapping techniques indicated that the distortion of the composite facesheets by the core gaps contributed to the premature failures. The repair methods used in this study did very little to improve the ultimate strength of the sandwich panels that previously had core gap defects. The repair of the thermoplastic panel resulted in a further loss in ultimate facesheet strength. This research demonstrated that there is a vital need for the development of a compatible thermoplastic polymer repair resin system and appropriate resin specific repair procedures for the next generation of recyclable thermoplastic wind blades.

17 WIND ENERGY↗

Methods for Computing Physically Realistic Estimates of Electric Water Heater Demand Response Resource Suitable for Bulk Power System Planning Models

Demand response is commonly called on to reduce load during system peak times or to respond to contingency events. In future power systems with higher shares of wind and solar generation (which we describe together as variable generation [VG]), demand response could have more opportunities to provide energy shifting or operating reserve services. This report evaluates the ability of residential electric water heaters, both electric resistance water heaters (ERWHs) and heat pump water heaters (HPWHs), to provide such services starting from detailed whole-building energy models that realistically represent New England single family home stock. We use a parsimonious surrogate model to represent operational flexibility in a form suitable for linear and mixed integer programming. This enables relatively fast determination of aggregate contingency reserve resource, price-taking energy shifting outcomes, and in some cases the determination of aggregate models at the megawatt (MW) scale that can be directly included in large-scale grid models. After selecting modeling methods and parameters through various computational experiments, we find interquartile ranges of contingency reserve resource in ISO-NE for about 603,400 ERWHs of 45 MW - 69 MW for Claim10 (50 minute responses provided with 10 minutes of advanced notification) and 65 MW - 102 MW for Claim30 (30 minute responses provided with 30 minutes of advanced notification), and for about 619,000 HPWHs of 48 MW - 88 MW for Claim10 and 52 MW - 90 MW for Claim30. The overall reserve resource is up to 32% of total load for ERWHs providing Claim10 service, 47% for ERWHs providing Claim30 service, 93% for HPWHs providing Claim10 service, and 97% for HPWHs providing Claim30 service. More work is required to determine if HPWHs are inherently more suitable than ERWHs for providing contingency reserve or if these results reflect idiosyncrasies of the single family home stock model used in this study. The value of this contingency resource in a Near-term VG model of ISO-NE is $\$ 0.40$ to $\$1.20$ per water heater-year, and significantly larger, $\$ 3.80$ to $\$ 5.30$ per water heater-year in a Mid-term VG model of ISONE. Aggregating surrogate models to the MW-scale for energy shifting service is more challenging than for contingency service and we only present such results for ERWHs, because we were unable to determine satisfactory ways to deal with HPWHs' time-varying and path dependent operational characteristics. Individual surrogate models suitable for evaluating the energy shifting resource from both ERWHs and HPWHs are created, however, and dispatched against day-ahead prices from the Near-Term VG and Mid-Term VG models of ISO-NE. The individual surrogate models are able to access and potentially shift all 640 GWh of HPWH load and 1,547 GWh of ERWH load we modeled in two different single family home stock models. In contrast, the most effective model of aggregate ERWH shifting resource we created only captured 34.7% of the total ERWH load. Energy shifting affected by price-taking dispatch against modeled day-ahead energy prices produces per water heater year profits of $\$19.44$ - $\$22.93$ for individual HPWHs, $\$39.11$ - $\$40.54$ for individual ERWHs, and up to $\$4.00$ - $\$4.24$ for aggregated ERWHs, with the variations mainly due to grid conditions (more or less VG). When the supply-side response to these changes is accounted for, the per water heater year production cost savings for ISO-NE are $\$7.50$ to $\$17.70$ for the most effective set of endogenously dispatched aggregate ERWHs, $\$15.60$ to $\$15.70$ for individual ERWHs dispatched against the DA prices, and $\$10.70$ to $\$11.20$ for individual HPWHs dispatched against DA prices. Those ranges primarily represent the difference between Near-Term VG and Mid-Term VG grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Some extemporaneous comments on our experiences with towers for wind generators

A wind generator tower must be designed to withstand fatigue forces and gust winds loads. Optimum tower height depends on the energy cost to the customer because an increase in height results in an increase in the cost of the plant. It is suggested that costs are minimum for the shortest tower possible and that the rotor should be as large as possible.

Hutter, U.↗

Determining the Reaction Time for Triggering Supportive Control Actions to Guarantee Adequate Frequency Response in Smart Grids

The progressive integration of renewable energy resources in the modern power grid can result in unsatisfactory frequency responses. To address this problem, wind turbine generators (WTGs), in particular, can be employed to support the power grid. Most works, however, only consider a simple step disturbance. In this paper, a new class of worst-case disturbances is introduced and their nefarious impact on renewable-penetrated power systems is investigated. The worst-case disturbances are derived using optimal control theory. More importantly, the proposed mechanism allows to determine the reaction time to trigger supportive control actions of WTGs to ensure satisfactory frequency response. Numerical results are provided and the effects of the worst-case disturbance on the reaction time are presented.

Luo, Jiecai↗

Comparison of wind farm control strategies under realistic offshore wind conditions: turbine quantities of interest

Abstract. Wind farm flow control is a strategy to increase the efficiency and therefore lower the levelized cost of energy of a wind farm. This is done using turbine settings such as the yaw angle, blade pitch angles, or generator torque to manipulate the flow behind the turbine, affecting downstream turbines in the farm. Two inherently different wind farm flow control methods have been identified in the literature: wake steering and wake mixing. This paper focuses on comparing the turbine quantities of interest between these methods for a simple two-turbine wind farm setup, while a companion article (Brown et al., 2025) focuses on the wake quantities of interest for a single wind turbine setup. Both papers use the same set of wind farm simulations based on high-fidelity large-eddy simulations (LESs) coupled with OpenFAST turbine models. First, precursor simulations are executed in order to match wind conditions measured with lidars in an offshore wind farm off the east coast of the USA. These measurements show general wind conditions that exhibit substantially higher vertical wind shear and veer than any of the LES studies performed with wind farm flow control strategies currently available in the literature. The precursors are used to evaluate the effectiveness of the control methods. In the LES, the wind veer leads to highly skewed wakes, which have considerable influence on the power uplift of wind farm flow control strategies. In addition to a baseline controller, four different control strategies, each of which uses either pitch or yaw control, are performed on the upstream turbine of a simple two-turbine wind farm. Assuming that the wind direction is known and constant over time, the simulations show that wake steering is generally the superior wind farm flow control strategy, considering both wind farm power production and turbine damage equivalent loads when substantial wind veer is present. This result is consistent over different wind speeds and wind directions. On the other hand, for similar wind conditions with lower veer, wake mixing was found to yield the highest power production, although at the expense of generally higher loads. This leads us to conclude that the effect of wind veer, which has so far not usually been considered, can not be neglected when determining the optimal wind farm flow control strategy.

17 WIND ENERGY↗