Investigating the influence of environmental information on perceived indoor environmental quality: An exploratory study

Under the assumption that information can impact perception, most research on human sensation and satisfaction with indoor environmental quality (IEQ) parameters has been conducted with respondents uninformed about the test conditions. Therefore, researchers know little about the impact of information on perception. These potential effects are increasingly relevant as quantitative information about indoor environments becomes accessible via low-cost, wirelessly connected sensors. In this experimental study, 48 subjects were exposed to varied indoor environmental conditions and provided with different types of environmental information. The subjects' sensation and satisfaction were compared when they were blinded or provided with quantitative information about and/or qualitative ratings of specific parameters. The results indicate that accurate information on parameter values influenced how the subjects perceived the indoor air quality (IAQ) but not how they perceived the thermal, acoustic, or visual quality. The subjects rated the IAQ more positively when they were informed that there were nonzero ventilation rates. The qualitative ratings influenced the subjects' perceptions of all four environmental factors, but in different directions. The subjects generally had more positive sensation and higher satisfaction when they were told that the parameter values and qualitative ratings were more favorable than the test conditions. However, the improved sensation and satisfaction were often not as good as when the environmental conditions were actually improved and the subjects were provided with accurate information. Here, these findings affirm the critical need for more research on the impacts of information on perceptions of the indoor environment.

42 ENGINEERING↗

Assessing the impacts of air-sealing on the sizing, operation, and economic feasibility of ground-source heat pumps for electrifying single-family houses in the US

According to recent studies and reports, in single-family houses (SFHs), air-sealing can significantly lower the thermal loads for space heating and cooling. Thus, air-sealing in SFHs could reduce the required size and cost of ground source heat pump (GSHP) systems for electrifying SFHs. Here, this study investigated the costs and benefits of integrating air-sealing with GSHPs for retrofitting existing SFHs when compared with air-source heat pumps. A whole building energy simulation tool integrated with an advanced design tool for modeling ground heat exchangers was used to calculate changes in required GSHP capacity, total borehole length, and building energy consumption with and without air-sealing in SFHs in 16 US climatic regions. The results from this study showed that reducing outdoor air infiltration from 0.8 air changes per hour (ACH) to the minimum ventilation requirement (0.35 ACH) can significantly reduce borehole length (up to 55 %), GSHP capacity (up to 48 %), and total heating electricity reduction, especially in cold climates (up to 44 %). The results also showed that for airtight homes (0.03 ACH infiltration) with a direct outdoor air system, the minimum required borehole length, GSHP capacity, and total heating electricity consumption can be reduced up to 70 %, 68 %, and 67 %, respectively, when compared with SFHs with 0.8 ACH infiltration. Moreover, the life cycle cost analysis showed that air-sealing in conjunction with a GSHP is more profitable than replacing the existing system with an air-source heat pump, even without any incentives for most climatic regions in the US (except for some hot regions).

15 GEOTHERMAL ENERGY↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of HVAC & refrigeration system fault behaviors and impacts: A systematic review

Achieving the goals of green buildings critically depends on the fault-free operation of heating, ventilation and air conditioning and refrigeration (HVAC&R) systems. However, faults frequently occur in these systems, causing a range of negative consequences, including increased energy consumption, diminished operational performance, compromised indoor environmental quality, higher operational costs, and shortened system lifespan. The evaluation of fault behaviors and impacts plays a critical role in revealing fault characteristics and consequently supports many research areas, including the design of the high-performance equipment, development of fault detection and diagnostics (FDD) and robust control approaches, as well as the enhancement of maintenance decision-making activities. This paper systematically reviews 112 research publications that reported the analysis and evaluation of fault behaviors and impacts in HVAC&R systems over the past thirty years. Here, we designed a review approach to address five crucial research questions, namely: 1) the objectives of analysis and evaluation of fault behaviors and impacts, 2) data sources, 3) equipment/system types and fault types, 4) evaluation methods including evaluation measures and associated metrics, and 5) challenges and future directions in the research on evaluating of fault behaviors and impacts. In-depth discussions on these questions help bridge the gap between the evaluation of fault behaviors and impacts and their practical applications, such as the development of high-performance systems, fault models, FDD methods, and maintenance decision-making tools within the HVAC&R FDD domain.

Chen, Yimin [Oak Ridge National Laboratory (ORNL),↗

Cloud-based implementation of white-box model predictive control for a GEOTABS office building: A field test demonstration

Model predictive control (MPC) has been proven in simulations and pilot case studies to be a superior control strategy for large buildings. MPC can utilize the weather and occupancy schedule forecasts, together with the system model, to predict the future thermal behavior of the building and minimize the overall energy use and maximize thermal comfort. However, these advantages come with the cost of increased modeling effort, computational demands, communication infrastructure, and commissioning efforts. Thus a typical approach is to, often rapidly, simplify the building modeling and MPC optimization problem while paying a price of not reaching the full performance potential. It has been shown that by employing accurate physics-based models, MPC performance can be notably increased closer to its theoretical performance bound. However, implementation of such high-fidelity MPC in real buildings remains a challenge, resulting in a lack of successful field test studies. This work presents the methodology and field test demonstration of a computationally efficient implementation of the white-box MPC in an office building in Belgium. The detailed model of the building is based on first-principle physical equations. The deployment and supervision of MPC operation in a practical setting are supported by an automated cloud-based communication infrastructure. The motivating factor behind the cloud-based architecture is its compatibility with a commercially appealing control as a service concept. The building is equipped with a ground source heat pump (GSHP) and thermally activated building structures (TABS), where the combination of both is also known as GEOTABS. From a control perspective, GEOTABS buildings are particularly challenging systems due to large scale, complex heating, ventilation and air conditioning (HVAC) system, and slow dynamics with time delays. On the other hand, there is an increased potential for energy savings due to the high thermal mass, which acts as thermal storage. The MPC operation is demonstrated during the challenging transient seasons (switching between heating and cooling), and its performance is compared to a traditional rule-based controller (RBC). We provide a proof of concept of real MPC operation for the most difficult seasons with notable GSHP energy use savings equal to 53.5% and thermal comfort improvement by 36.9%. Other MPC applications found in the literature describe tests for only cooling or only heating, and up to now only for a black-box or a grey-box approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantitative and three-dimensional assessment of holdup material

Nuclear material deposited in equipment, transfer lines, and ventilation systems of a processing facility is usually referred to as holdup. Operators need to know the location and amount of holdup in their facility for radiation safety and material accountability. In this work, we propose to use an array of detectors co-axial to the inspected pipe to measure the holdup material. This method is implementable into an automated system capable of crawling on surfaces and pipes of various curvatures, which would enable faster, easier, and more accurate holdup safeguards measurements. We first demonstrated that the current holdup assay procedure could lead to a non-negligible bias in the estimate of special nuclear material mass, due to the simplified assumption of deposited geometry introduced by the Generalized Geometry Holdup (GGH) model. The new approach consists of imaging the inner holdup material by characterizing the detector array’s response and unfolding it from the measured light output. Our experimental proof of principle consists of three NaI(Tl) detectors surrounding an aluminum pipe containing two cesium-137 ( 137 Cs) sources. We derived the source distribution inside the pipe by first calculating the detector response matrix using a method adaptive to the surface geometry of the object containing the measured holdup material. Creating a matrix of the detector array’s measured counts, we then proceed to solve an inverse problem, resulting in an accurately located source position and activity distribution within the response matrix’s spatial resolution. Furthermore, we then developed a simulated model of the envisioned experimental setup, which accurately described both the activity and position of the source in 2D. Finally, we extended our model onto a discretized three-dimensional model of the system, encompassing 36 detectors. The model was simulated to measure the source distribution and activity of multiple sources in pipes of varied geometries, which could then be conveniently translated to a real-time holdup measurement protocol. For the 3D simulation of four different source geometries, the model accurately localized the source position in 3D, while the activity retained a maximum relative error of ±5.32%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geothermal district energy systems coupled with seasonal underground thermal energy storage: a U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

25 ENERGY STORAGE↗

Mitigation of safety and environmental challenges posed by refrigerants

The abatement of safety and environmental burden associated with low and ultra-low Global Warming Potential (GWP) refrigerants is a critical undertaking. As the industry shifts towards more environmentally friendly alternatives, mitigating the potential risks and ensuring safety standards becomes paramount. The adoption of mildly and highly flammable refrigerants contributes significantly to minimizing the greenhouse gas impact on the environment, aligning with global climate and sustainability goals. However, it is essential to address safety concerns and potential environmental implications associated with the end use of these refrigerants. A method to mitigate the safety risk in a flammable refrigerant based heating, ventilation, air-conditioning, and refrigeration (HVACR) system is the primary focus of this paper. Advent of A2L and A3 refrigerants as replacements to high GWP refrigerants requires careful handling of leak episodes to lower or eliminate the risk associated with creating flammable mixtures capable of fire/explosion hazard. Solid materials tailored to target the molecule of interest (i.e., refrigerant.) by engineering the microporous structure as well as chemically functionalizing the surface to attract and hold on to the chemical compound being removed from the gas stream was realized. Quantitative analysis reveals the adsorbent's effectiveness in reducing leak potential in the range of 40 %–100 % for various refrigerants. Strategic placement and active leak management with negative pressure offer promising avenues for capturing leaked refrigerants, enhancing overall safety.

42 ENGINEERING↗

Enhanced ZIF-8-enabled colorimetric CO 2 sensing through dye-precursor synthesis

The accumulation of carbon dioxide (CO 2 ) within enclosed spaces, along with volatile organic compounds, under certain humidity, temperature, and ventilation conditions is associated with detrimental human health symptoms such as fatigue. Color-based chemical sensing is a promising approach to detect CO 2 levels relevant to indoor air quality through producing fast, quantifiable output visible to the naked eye. In a prior work, a colorimetric gas sensor was fabricated through synthesizing the metal-organic framework, ZIF-8, as the adsorbent, followed by post-synthetic mixing with a dye, phenol red (PSP), and primary amine, ethylenediamine (ED). While this sensor (termed PSP-ED/ZIF-8) maintained its structural integrity in atmospheric conditions and exhibited an increasing fuchsia-to-yellow color change with increasing CO 2 levels in dry environment, the colorimetric response greatly suffered in the presence of humid CO 2 . Here in this work, a significantly improved colorimetric CO 2 sensor (referred to as ED/PSP:ZIF-8) is accomplished through directly incorporating phenol red in the ZIF-8 metal and linker precursor solutions and then blending with ethylenediamine. MATLAB-generated color distributions and in-situ ultraviolet-visible (UV-Vis) spectroscopic studies quantitatively demonstrate an enhanced colorimetric gas response of ED/PSP:ZIF-8 compared to that of PSP-ED/ZIF-8 across an important range of CO 2 for indoor air quality monitoring (500 – 3500 ppm) and across a range of humidity. The new sensor also exhibits high selectivity to CO 2 compared to select volatile organic compounds, such as acetone and ethanol, which contribute to human health symptoms experienced indoors. The enhanced performance is attributed to the proposed incorporation of phenol red within ZIF-8, while maintaining the chemical stability of the MOF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupled management of electric vehicle workplace charging and office building loads

Significant building energy savings are realized through heating, ventilation, and air conditioning (HVAC) setpoint adjustment and daylighting control. Workplace charging (WPC) enables colocation of electric vehicles (EVs) with office building loads. We proposed managing energy use of workplace EV charging and the office building and determined the number of EVs that building energy savings can facilitate charging. We simulated building energy savings in typical medium offices in Chicago IL, Baltimore MD, and Houston TX, spanning three US climate regions. Considering the EV hosting capacity of the saved building energy and travel patterns of roundtrip commuting, we minimized EV charging costs under time-of-use electricity pricing. Managed WPC can reduce charging electricity bills compared to first-come, first-served charging. The ratio of EVs to chargers, the coincident period of commuters’ dwell time and lower electricity prices, and the number of EVs in the office impacted the economic benefits achieved through charging management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Involvement of TFAP2A in the activation of GSDMD gene promoter in hyperoxia-induced ALI

Highlights: • Hyperoxia exposure increases GSDMD expression in rat lung tissue and A549 cells. • The core promoter region of GSDMD located in −98/-12 bp relative to TSS. • E2F4 and TFAP2A positively regulate the basal transcriptional activity of GSDMD by directly binding to its promoter. • TFAP2A directly drives the expression of GSDMD in hyperoxia-inducedA549 cells. • TFAP2A expression is increased in lung tissues of rats with hyperoxia-induced ALI and linearly correlated with GSDMD. Oxygen therapy is a common treatment in neonatal intensive care units, but long-term continuous hyperoxia ventilation may induce acute lung injury (ALI). Gasdermin D (GSDMD)-mediated pyroptosis participates in various diseases including ALI, but the role of GSDMD in hyperoxia-induced ALI is yet understood. Here, we showed a significant increase in GSDMD after exposure to high oxygen. To elucidate the molecular mechanisms involved in GSDMD regulation, we identified the core promoter of GSDMD, −98 ~ −12 bp relative to the transcriptional start site (TSS). The results of mutational analysis, overexpression or siRNA interference, EMSA and ChIP demonstrated that E2F4 and TFAP2A positively regulate the transcriptional activity of the GSDMD by binding to its promoter. However, only TFAP2A showed a regulatory effect on the expression of GSDMD. Moreover, TFAP2A was increased in the lung tissues of rats exposed to hyperoxia and showed a strong linear correlation with GSDMD. Our results indicated that TFAP2A positively regulates the GSDMD expression via binding to the promoter region of GSDMD.

60 APPLIED LIFE SCIENCES↗

A physiologically based pharmacokinetic (PBPK) model to align dosimetry of the isobutyl metabolic series in rats and humans

Here, we developed a physiologically based pharmacokinetic (PBPK) model in rats and humans for the isobutyl metabolic series including isobutyl acetate, isobutanol, isobutyraldehyde, and isobutyric acid. Chemical manufactures routinely use these compounds as solvents, for chemical synthesis, as potential biofuels, de-icing fluids, and additives for food and/or fragrance in consumer products. Human exposure to isobutyl compounds can occur through inhalation or oral routes. We previously developed a PBPK model for the propyl metabolic series and utilized it as a framework to create the isobutyl PBPK model due to the chemical similarities between the two series. To support model development, we measured in vitro metabolism of isobutyl acetate in rat and human blood and liver S9 fractions. Compared to rats, humans demonstrated faster isobutyl acetate hydrolysis in liver S9 fractions, while the hydrolysis rates in blood were similar between the two species. We used concentrations of isobutyl compounds measured in air and blood from rats exposed to isobutyl acetate and isobutanol as well as other published data to further parameterize the model. Following exposure to either isobutyl acetate or isobutanol, we observed isobutanol concentrations highest among the isobutyl compounds in the blood of rats. Overall, the model accurately predicts measured time course concentrations of isobutyl acetate, isobutanol, and isobutyric acid in available data in rats and humans. Sensitivity analyses identified alveolar ventilation rates, isobutyl metabolism rates, and cardiac output as the most sensitive parameters affecting concentrations of isobutyl compounds in blood. The isobutyl PBPK model enables comparisons of internal dose metrics across various isobutyl compound exposures and species and allows for calculation of equivalent external exposures that result in the same dose metric. Regulators can employ this PBPK model to predict and align internal dose metrics of isobutyl compounds for risk assessment purposes.

2-methyl-1-propanol↗

COVID-19: Effects of Environmental Conditions on the Propagation of Respiratory Droplets

As coronavirus disease 2019 (COVID-19) continues to spread, a detailed understanding on the transmission mechanisms is of paramount importance. The disease transmits mainly through respiratory droplets and aerosol. Although models for the evaporation and trajectory of respiratory droplets have been developed, how the environment impacts the transmission of COVID-19 is still unclear. In this study, we investigate the propagation of respiratory droplets and aerosol particles generated by speech under a wide range of temperatures (0–40 °C) and relative humidity (0–92%) conditions. We show that droplets can travel three times farther in low-temperature and high-humidity environment, whereas the number of aerosol particles increases in high-temperature and low-humidity environments. The results also underscore the importance of proper ventilation, as droplets and aerosol spread significantly farther in airstreams. This study contributes to the understanding of the environmental impact on COVID-19 transmission.

60 APPLIED LIFE SCIENCES↗

Coalescence-Induced Spontaneous Shedding of Microdroplets on Superhydrophobic Surfaces Featuring Enclosed Micropillars with Hierarchical Roughness

This study investigated water vapor condensation on superhydrophobic surfaces (SHSs) featuring micropillars enclosed by wall lattices and having three-tier hierarchical roughness. A total of five samples were created with three (NW-J, W200-J and W400-J samples) having large micropillar depth (~6 μm) and two (NW-S and W200-S samples) having small micropillar depth (~1 μm). Two distinct condensate removal modes were observed during condensation: coalescence-induced jumping on samples with large micropillar depth and coalescence-induced shedding on samples with small micropillar depth. The results showed that the diameter of the shedding droplet on the W200-S sample having small micropillar depth could be as small as 107 μm, as compared to the theoretical critical diameter of 267 μm for gravitational shedding on the same sample. The enhanced functionality of the three-tier nanotextures on the W200-S sample could effectively suppress localized pinning of the three-phase contact line and Wenzel neck formation during the growth of condensate droplets. Consequently, during multidroplet coalescence, the released surface energy easily overcomes the solid–liquid adhesion, leading to spontaneous shedding of merged droplets. The inclusion of the wall lattice aids condensate growth by the droplet self-alignment along the walls and promoting coalescence. As a result, the W200-S sample exhibited the highest condensate collection as well. In conclusion, the proposed surface design has great potential for scaling up and implementation in heating, ventilation, and air-conditioning equipment due to the simplicity of the surface morphology and the facile spray-coating method used to achieve hierarchical roughness.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemical Synthesis of Zeolite Coatings with Controlled Crystal Polymorphism and Self-Regulating Growth

Zeolite coatings are studied as molecular sieves for membrane separation, membrane reactors, and chemical sensor applications. They are also studied as anticorrosive films for metals and alloys, antimicrobial and hydrophobic films for heating, ventilation, and air conditioning, and dielectrics for semiconductor applications. Zeolite coatings are synthesized by hydrothermal, ionothermal, and dry-gel conversion approaches, which require high process temperatures and lengthy times (ranging from hours to days). Here, we report the first zeolite coatings synthesized via electrochemical deposition on a cathodic electrode, with controlled crystal polymorphism achieved within subhourly duration. We demonstrate this approach by developing sodium zeolite (e.g., sodalite (SOD), NaA (LTA), and Linde Type N (LTN)) coatings on a titanium electrode and extending the synthesis method to porous stainless steel. The coating morphology and crystallinity depend on the temperature, time, and applied current. The coating thickness is independent of the applied current, showing the presence of a self-regulating mechanism to ensure a uniform coating thickness across the metal surface. The electrochemical zeolite growth mechanism was elucidated with high-resolution transmission electron microscopy, and applications of the resultant zeolite coatings for oil/water separation and ethanol/water pervaporation were exploited. Electrochemical synthesis represents a novel, simple, fast, and environmentally friendly approach to preparing zeolite coatings. It can potentially be generalized for developing zeolite materials with diverse framework structures, morphologies, and orientations for substrates with complicated geometries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulations With the Marine Biogeochemistry Library (MARBL)

Abstract The Marine Biogeochemistry Library (MARBL) is a prognostic ocean biogeochemistry model that simulates marine ecosystem dynamics and the coupled cycles of carbon, nitrogen, phosphorus, iron, silicon, and oxygen. MARBL is a component of the Community Earth System Model (CESM); it supports flexible ecosystem configuration of multiple phytoplankton and zooplankton functional types; it is also portable, designed to interface with multiple ocean circulation models. Here, we present scientific documentation of MARBL, describe its configuration in CESM2 experiments included in the Coupled Model Intercomparison Project version 6 (CMIP6), and evaluate its performance against a number of observational data sets. The model simulates present‐day air‐sea CO 2 flux and many aspects of the carbon cycle in good agreement with observations. However, the simulated integrated uptake of anthropogenic CO 2 is weak, which we link to poor thermocline ventilation, a feature evident in simulated chlorofluorocarbon distributions. This also contributes to larger‐than‐observed oxygen minimum zones. Moreover, radiocarbon distributions show that the simulated circulation in the deep North Pacific is extremely sluggish, yielding extensive oxygen depletion and nutrient trapping at depth. Surface macronutrient biases are generally positive at low latitudes and negative at high latitudes. CESM2 simulates globally integrated net primary production (NPP) of 48 Pg C yr −1 and particulate export flux at 100 m of 7.1 Pg C yr −1 . The impacts of climate change include an increase in globally integrated NPP, but substantial declines in the North Atlantic. Particulate export is projected to decline globally, attributable to decreasing export efficiency associated with changes in phytoplankton community composition.

Meteorology & Atmospheric Sciences↗

Evidence of a South Asian Proto‐Monsoon During the Oligocene‐Miocene Transition

Abstract The geological history of the South Asian monsoon (SAM) before the Pleistocene is not well‐constrained, primarily due to a lack of available continuous sediment archives. Previous studies have noted an intensification of SAM precipitation and atmospheric circulation during the middle Miocene (∼14 Ma), but no records are available to test how the monsoon changed prior to this. In order to improve our understanding of monsoonal evolution, geochemical and sedimentological data were generated for the Oligocene‐early Miocene (30–20 Ma) from Indian National Gas Hydrate Expedition 01 Site NGHP‐01‐01A in the eastern Arabian Sea, at 2,674 m water depth. We find the initial glaciation phase (23.7–23.0 Ma) of the Oligocene‐Miocene transition (OMT) to be associated with an increase in water column ventilation and water mass mixing, suggesting an increase in winter monsoon type atmospheric circulation, possibly driven by a relative southward shift of the intertropical convergence zone. During the latter part of the OMT, or “deglaciation” phase (23.0–22.7 Ma), a long‐term decrease in Mn (suggestive of deoxygenation), increase in Ti/Ca and dissolution of the biogenic carbonate fraction suggest an intensification of a proto‐summer SAM system, characterized by the formation of an oxygen minimum zone in the eastern Arabian Sea and a relative increase of terrigenous material delivered by runoff to the site. With no evidence at this site for an active SAM prior to the OMT we suggest that changes in orbital parameters, as well as possibly changing Tethyan/Himalayan tectonics, caused this step change in the proto‐monsoon system at this intermediate‐depth site.

Beasley, C.↗

Cyclic Background Noise Variations on Infrasound Microbarometers From Micrometeorology and Human Activity

Infrasound microbarometers deployed on the Earth's surface capture pressure fluctuations and acoustic signatures, revealing trends in surface wind speed and cycles in ambient sound. Previous studies investigated wind noise trends at quarter day resolution and urban acoustic background variations on hourly to weekly scales. Cyclic variations at sub-hourly resolution over local distances remain unaddressed. We show that topography-driven micrometeorology impacts diurnal background noise levels below 10 Hz. Anthropogenic noise occurs over daily and weekly cycles, with inputs from traffic, ventilation systems, and power lines. These noise patterns vary at stations spaced less than a kilometer apart. We observe these phenomena by using a circular spectrogram to visualize frequency trends over a periodic temporal scale. This study demonstrates that infrasound microbarometer deployments can highlight localized wind patterns and time scales of human activity. The results suggest that future microbarometer deployments may benefit from site noise surveys before selecting final sensor locations.

Malach, Amrit Kaur [Sandia National Lab. (SNL-CA),↗