Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ventilation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Quantifying Occupant Health and Productivity for Deep Retrofits: Beyond Traditional IEQ Studies

As energy-efficiency standards for both new construction and existing building renovations become more stringent, further reductions become less tractable and more expensive. With increasing interest and rising investment in healthy built environments, integrating energy efficiency with improved occupant experience (i.e., health, comfort, and work performance) offers a new path to drive deep energy retrofits. However, the difficulty in quantifying and verifying health and productivity gains from building upgrades leads to lower valuation of human benefits in practice. Building codes and standards have progressive energy targets but often give minimum requirements to occupant health for factors such as ventilation and thermal comfort. State and federal laws in the United States that govern the energy service performance contract (ESPC) have no clear and consistent guidance on quantifying non-energy benefits and incorporating them into a formal cost-effectiveness analysis. This paper presents a methodology to measure a building’s potential performance improvement regarding occupant health based on existing evidence correlating IEQ to occupant outcomes. Health improvement measures are integrated with a building energy model to identify and measure the impact of holistic improvement strategies. The net present value of these measures is determined based on the investment costs required to attain those improvements, energy savings, and personnel gains. We will discuss results from one pilot building, which showed nearly $50 per square foot 20-year net present value using the integrated approach.

Keene, Kevin M.↗

Long-term trends in connected thermostat performance

Internet-connected thermostats (CTs) control heating and cooling systems in about 30% of North American homes, and capture half of annual thermostat sales. In 2017 the U.S. Environmental Protection Agency created a program to certify the performance of ENERGY STAR® Connected Thermostats. To demonstrate compliance with energy-saving criteria, thermostat vendors must submit performance summaries for a representative sample of up to 1250 homes. Vendors must then re-submit results from a new, representative sample every six months in order to maintain their ENERGY STAR certification. This procedure has created a unique record of each thermostat’s long-term performance in response to changes in weather, customer demographics, building stock, and algorithms. Our analysis covers submissions from 13 different vendors, who submitted data up to 7 times over four years. We found that these semi-annual samples generated relatively stable trends for comfort temperatures and Heating, Ventilating and Air Conditioning (HVAC) runtimes over the study period. However, some vendors achieved consistently more energy-conserving comfort temperatures and shorter HVAC runtimes than others. The most recent submission runtimes averaged 700 hours for heating and 1,300 hours for cooling, but some vendors achieved runtimes as much as 17% below the mean. This implies lower energy consumption is due in large part to more successful algorithms and control strategies used by those vendors.

Meier, Alan↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources

Integrating a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problems requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (controllable DERs), including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperforms other benchmark controllers regarding computation time without compromising operational performance.

DER↗

Occupancy-Based Controls for an All-Electric Residential Community in a Cold Climate: Preprint

In residential buildings, rapid improvements in sensors, communication, and information technology have enabled occupancy-based building controls. These controls utilize occupancy information and modify the operation of the heating, ventilation, and air-conditioning (HVAC) system to minimize excess HVAC energy use, especially when the building is unoccupied. This reduces the total building energy consumption and utility bills while maintaining thermal comfort. In this paper, we present two novel occupancy-driven controls - reactive control and predictive control - and compare their performance. We model an all-electric residential community based on a 27- home community in Basalt, Colorado, in the United States. We simulated various scenarios, considering different temperature setback and control algorithms, to analyze the community-scale impact of these occupancy-based controls. The results show that total HVAC energy savings in a building ranges from 1%- 20% compared to the baseline scenario without occupancy-based controls. The energy-saving potential is highly correlated with the occupancy pattern and temperature setback in the building.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Validation of HVAC Hardware-in-the-Loop Simulation for Advanced Control Strategies in Smart Homes: Preprint

Residences with smart thermostats can use advanced control strategies to manage their cooling/heating demand, but it is difficult to evaluate optimal control strategies for flexible heating, ventilation, and air conditioning (HVAC) systems in a traditional laboratory setting. The HVAC hardware-in-the-loop (HIL) system combines physical HVAC equipment and a physical thermostat with a simulated house to enable realistic operation of the hardware in any climate. This HIL platform allows researchers to evaluate advanced control strategies for homes with different construction or vintage types, as well as different climates and occupancy schedules. To demonstrate the capabilities of the HVAC HIL system, experimental results with a SEER 16, HSPF 9.5, 3 ton single-speed air source heat pump are validated against past field data collected from a heavily instrumented, unoccupied, retrofit house located in Sacramento, California. Three different cooling strategies are recreated in the HVAC HIL platform, including two different pre-cooling schedules that were designed to shift energy use away from the evening peak. The room temperatures, heat pump energy use, and run time show good agreement between the field data and HIL experimental results for three strategies.

cooling strategies↗

Accelerating Optimal Integration of Energy Efficiency Strategies with Industrialized Modular Construction: Preprint

The National Renewable Energy Laboratory's (NREL's) Industrialized Construction Innovation team first introduced the Industrialized Construction Assessment Framework to achieve affordable, net-zero energy (NZE) modular multifamily buildings in the 2020 ACEEE paper "Integrating Energy Efficiency Strategies with Industrialized Construction for our Clean Energy Future." Since then, NREL has continued to drive the ambitious plan to accelerate optimal integration of energy efficiency strategies during industrialized construction with little or no additional cost, labor, and production time. This follow-on paper introduces the Energy in Modular (EMOD) buildings method and presents NREL's research efforts over the last two years in collaboration with industry, including affordable housing partners. NREL has developed an idealized NZE modular multifamily building design that incorporates five energy efficiency strategies well suited for industrialized construction in factories: (1) envelope thermal control, (2) envelope infiltration control, (3) mechanical, electrical, and plumbing systems, (4) smart controls, and (5) solar plus storage. This paper highlights results from leveraging design for manufacturing and assembly principles, testing, and validation pilots with factory partners; demonstrating pod prototypes in test stand at NREL; and performing simulations. Overall, these research efforts address barriers to whole-building system integration, such as poor installation quality of thermal and air barriers; lack of unitized systems for space conditioning, energy recovery and ventilation, and water heating; problematic on-site installation, commissioning, and configuration of controls; and lack of cost-effective integration for grid-friendly design and emerging technologies. Conclusively, the paper delineates next steps for future work with NREL's partners toward developing a transformational pathway for our clean energy future.

affordable housing↗

A Commercial Building Plug Load Management System that Uses Internet of Things Technology to Automatically Identify Plugged-In Devices and Their Locations

Plug and process loads (PPLs) account for a large portion of U.S. commercial building energy use. There is a huge potential to reduce whole building consumption by targeting PPLs for energy savings measures or implementing some form of plug load management (PLM). Despite this potential, there has yet to be a widely adopted commercial PLM technology. This paper describes the Automatic Type and Location Identification System (ATLIS), a PLM system framework with automatic and dynamic load detection (ADLD). ADLD gives PLM systems the ability to automatically identify devices as they are plugged into the outlets of a building. The ATLIS framework takes advantage of smart, connected devices to identify device locations in a building, meter and control their power, and communicate this information to a central database. ATLIS includes five primary capabilities: location identification, communication, control, energy metering, and data storage. A laboratory proof of concept (PoC) demonstrated all but the energy metering capability, and these capabilities were validated using a series of system tests. The PoC was able to identify when a device was plugged into an outlet and the location of the device in the building. When a device was moved, the PoC's dashboard and database were automatically updated with the new location. The PoC implemented controls to devices from the system dashboard so that devices maintained correct schedules regardless of where they were plugged in within the building. ATLIS's primary technology application is improved PLM, but other applications include asset management, energy audits, and interoperability for grid-interactive efficient buildings. An ATLIS-based system could also be used to direct power to critical devices, such as ventilators, during a brownout or blackout. Such a framework is an opportunity to make PLM more widespread and reduce the amount of energy consumed by PPLs in current and future commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Risk Mitigation Guidance for Hydrogen Sensor Placement Indoors and Outdoors

Guidance on Sensor Placement remains one of the top priorities for the safe deployment of hydrogen and fuel cell equipment in the commercial marketplace. Building on the success of Phase 1 work reported at ICHS2019 and published in IJHE, this paper discusses the consecutive steps to further develop and validate such guidance for mechanically ventilated enclosures. The key step included a more in-depth analysis of sensitivity to variation of physical parameters in a small enclosure, and finally, expansion of the developed approach to confined spaces in an outdoor environment.

codes and standards↗

Microbial sensor system for monitoring the environment and surfaces

A microbial sensor, system and method that can be used to determine the biochemical conditions of waters, saturated sediments, unsaturated soils, rhizosphere and other environments is disclosed. The flexibility of the microbial sensor design allows for the monitoring of surfaces (skin, ventilation conduits, etc.). An electrochemical microbial sensor system is composed of an indicator electrode(s) and a reference electrode. The reference electrode employs a hydrogen permeable membrane. The electrochemical system is interfaced into a signal/communication module allowing the manual or automated collection of data from field deployments and laboratory investigations. The data is transmitted using various communication technologies including Bluetooth™, cellular, satellite and radio telemetry to cloud-based data management systems. The stored data may be downloaded by users using open-source dashboard and visualization software to image the various environments and/or surfaces investigated.

Burge, Scott R.↗

Automated cryogenic refilling system

An improved system and method for the automated refilling of cryogenic helium is provided. In one embodiment, the system includes a dewar in fluid communication with a liquid helium cryostat through a cryogen transfer line. A controller regulates operation of a three-way valve to pre-cool the transfer line and to cause gaseous helium to flow to the dewar and force liquid helium through the transfer line into the cryostat. The controller is coupled to the output of a cryogenic level sensor, such that the controller regulates the helium liquid level within the cryostat. During filling cycles, the dewar liquid level is also monitored by the cryogenic level sensor and an alarm sounds if the dewar liquid level is undesirably low. Between filling cycles, the controller is operable to ventilate the dewar through a solenoid vent valve in fixed time intervals to ensure the dewar pressure is sufficiently low so as to not bleed liquid helium into the cryostat.

Ruiz-Rodriguez, Mariano M.↗

Connecting the Dots: An Assessment of Cyber-risks in Networked Building and Municipal Infrastructure Systems

The buildings and city streets we walk down are changing. Driven by various data-driven use cases, there is increased interest in networking and integrating lighting and other building systems (e.g., heating, ventilation, and air conditioning (HVAC), security, scheduling) that were previously not internet-facing, and equipping them with sensors that collect information about their environment and the people that inhabit it. These data-enabled systems can potentially deliver improved occupant and resident experiences and help meet the U.S. Department of Energy (DOE) national energy and carbon reduction goals. Deploying connected devices new to being networked, however, is not without its challenges. This paper explores tools available to system designers and integrators that facilitate a cybersecurity landscape assessment – or more specifically the identification of threats, vulnerabilities, and adversarial behaviors that could be used against these networked systems. These assessments can help stakeholders shift security prioritization proactively toward the beginning of the development process.

cyber-risk assesment, adversarial behavior, MITRE ↗

Reduced Order Model to Predict Dispersion of Flammable Refrigerant into a Space

As the HVAC&R industry mobilizes to deploy more low-GWP refrigerants, relevant standards are being continually reviewed and updated. Those include the general safety standards ISO 5149 and ASHRAE 15, and the equipment standards IEC and UL. The standards systematically set the allowable maximum amount of refrigerant that should be used in different equipment types and different applications. To do so, they rely on predictions of how a leaked refrigerant mass will disperse into a space. Dispersion characteristics, such as total flammable volume and its residence time, determine the risk associated with the presence of the flammable refrigerant. The standards have included provisions for the use of flammable refrigerants for approximately two decades. They relied on limited analytical analyses and test cases in their development. Dispersion of a refrigerant into a space is complex. Computational fluid dynamics (CFD) are the most accurate in predicting a given problem. However, CFD is computationally expensive and requires specialized expertise and resources and is not suitable for use by standards development working group as prediction tool. This paper presents the development of a reduced order model (ROM) that predicts the key dispersion characteristics relevant to the dispersion of a leaked refrigerant into a space for any combination of input variables. The inputs are the refrigerant release height, the total released refrigerant mass and its release flow rate, the refrigerant molecular weight, the ventilation flow rate, the floor area and height of the space, recirculation air flow rate, and the tightness of the space. The outputs are histograms of volume fraction of the room in prescribed concentration bins and the total mass of the refrigerant in each bin normalized by the total refrigerant charge at 13 prescribed simulation time stamps between 1 and 900 seconds. The ROM is constructed from a set of CFD simulations with carefully chosen combinations of input parameters. The selection if done using a multidimensional sparse grid which is a generalization of the classical tensor approach but offers additional flexibility and thus can be more carefully tuned towards a specific model. The tuning is done to improve the accuracy, measured in the difference between the output values of the ROM and the CFD model, while minimizing the computational cost, measured in number of CFD simulations which is orders of magnitude more expensive than the processing the training data.

Edwards, Dean↗

Modeling and Experiments on a Dedicated Outdoor Air System Using Liquid Desiccant Heat and Mass Exchangers

Liquid desiccants can provide efficient dehumidification but have yet to see widespread adoption. Most systems studied previously use natural gas-combustion to heat and regenerate the desiccant, and a central chiller plant or cooling tower for removing the heat of absorption. Here we present modeling and experimental results on a novel packaged air conditioner integrating liquid-desiccant heat and mass exchangers with a vapor compression cycle. The packaged system does not need cold or hot water from a central plant or cooling tower and is suitable for rooftop unit air conditioners. The system uses the evaporator to cool the liquid desiccant that is absorbing moisture from the air, and the condenser to heat the liquid desiccant to regenerate it. Efficiency is improved by reducing the load on the evaporator for a given supply-air dewpoint. This paper presents the measured dehumidification efficiency for a 10- ton packaged air conditioner, focusing on dehumidifying ventilation air. The paper also presents a numerical model to predict the outlet conditions and dehumidification efficiency, which we compare with the measured data.

air conditioning↗

Gaseous hydrogen storage system with cryogenic supply

A gaseous hydrogen storage and distribution system with a cryogenic supply and a method for the cryogenic conversion of liquid hydrogen into high-pressure gaseous hydrogen are provided. The gaseous hydrogen storage and distribution system includes pressuring liquid hydrogen from a cryogenic tank using a low pressure liquid pump before vaporization within a relatively small vaporizer. The resulting high pressure gaseous hydrogen is transferred to a plurality of storage tanks at ambient temperature according to a desired fill sequence. The high pressure hydrogen gas is subsequently distributed from the storage tanks through a hydrogen fueling dispenser according to a desired dispensing sequence. The present system and method provide improvements in operational safety, eliminates the use of high pressure gas compressor, and minimizes boiling off and ventilation losses at a reduced cost when compared to existing thermal compression storage systems.

Feng, Zhili↗

System and method for characterization of air leakage in building using data from communicating thermostats and/or interval meters

Systems and methods for characterization of retrofit opportunities are described. Some embodiments are directed to methods for determining the air leakage rate of a building, and accordingly, for determining suitability of sealing of air leaks to improve the energy efficiency of a building. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter. To isolate the impact of air leakage, subsets of the HVAC runtime data at time intervals selected to have substantially the same conditions, but different wind speeds, may be computed.

Zeifman, Michael↗