Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Endogenous Assessment of the Capacity Value of Solar PV in Generation Investment Planning Studies

There exist several different reliability-and approximation-based methods to determine the contribution of solar resources toward resource adequacy. However, most of these approaches require knowing in advance the installed capacities of both conventional and solar generators. This is a complication since generator capacities are actually decision variables in capacity planning studies. In this paper, we study the effect of time resolution and solar PV penetration using a planning model that accounts for the full distribution of generator outages and solar resource variability. We also describe a modification of a standard deterministic planning model that enforces a resource adequacy target through a reserve margin constraint. Our numerical experiments show that at least 50 days worth of data are necessary to approximate the results of the full-resolution model with a maximum error of 2.5% on costs and capacity. We also show that the amount of displaced capacity of conventional generation decreases rapidly as the penetration of solar PV increases. We find that using an exogenously defined and constant capacity value based on time-series data can yield relatively accurate results for small penetration levels. For higher penetration levels, the modified deterministic planning model better captures avoided costs and the decreasing value of solar PV.

14 SOLAR ENERGY↗

The Value of Spatial Information for Determining Well Placement

The article and accompanying spreadsheet represent the information posteriors derived from synthetic data of magnetotellurics (MT). These were used to calculate value of information of MT for geothermal exploration. Information posteriors describe how well MT was able to locate the "throat" of clay caps, which are indicative of hidden geothermal resources. This data is fully explained in the peer-reviewed publication: The value of spatial information for determining well placement: a geothermal example, written by Trainor-Guitton, W., Hoversten, G. M., Ramirez, A., Roberts, J., Juliusson, E., Key, K., and Mellors, R. and published on August 25th, 2014.

15 GEOTHERMAL ENERGY↗

Valuing Energy Security: Customer Damage Function Methodology and Case Studies at DoD Installations

This report describes a methodology to value non-energy savings that can be attributed to energy security projects. The methodology is based on: (1) completing a site survey to collect data on two hypothetical outage scenarios lasting for different durations to compute a customer damage function (CDF), which represents interruption costs as a function of the outage duration; (2) characterizing the reliability of the commercial power supply at the site; and (3) estimating the value of electrical energy security (VEES), which is a metric that characterizes on an annual basis the cost of utility outages. The avoided cost of commercial power outages can be used as ancillary non-energy savings to increase the return on investment of energy security projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulating the Value of Concentrating Solar Power with Thermal Energy Storage in a Production Cost Model

Concentrating solar power (CSP) deployed with thermal energy storage (TES) provides a dispatchable source of renewable energy. The value of CSP with TES, as with other potential generation resources, needs to be established using traditional utility planning tools. Production cost models, which simulate the operation of grid, are often used to estimate the operational value of different generation mixes. CSP with TES has historically had limited analysis in commercial production simulations. This document describes the implementation of CSP with TES in a commercial production cost model. It also describes the simulation of grid operations with CSP in a test system consisting of two balancing areas located primarily in Colorado.

14 SOLAR ENERGY↗

Moisture Management for High R-Value Walls

The following report explains the moisture-related concerns for High R-value wall assemblies and discusses past Building America research work that informs this study. Hygrothermal simulations were prepared for several common approaches to High R-value wall construction in six cities (Houston, Atlanta, Seattle, St. Louis, Chicago, and International Falls) representing a range of climate zones (2, 3, 4C, 4, 5A, and 7, respectively). The simulations are informed by experience gained from past research in this area and validated by field measurement and forensic experience. The modeling program was developed to assess the moisture durability of the wall assemblies based on three primary sources of moisture: construction moisture, air leakage condensation, and bulk water leakage. The peak annual moisture content of the wood based exterior sheathing was used to comparatively analyze the response to the moisture loads for each of the walls in each given city. Walls which experienced sheathing moisture contents between 20% and 28% were identified as risky, whereas those exceeding 28% were identified as very high risk. All of the wall assemblies perform well under idealized conditions. However, only the walls with exterior insulation, or cavity insulation which provides a hygrothermal function similar to exterior insulation, perform adequately when exposed to moisture loads. Walls with only cavity insulation are particularly susceptible to air leakage condensation. None of the walls performed well when a precipitation based bulk water leak was introduced to the backside of the sheathing, emphasizing the importance of proper flashing details.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. Residential Photovoltaic (PV) System Prices, Q4 2013 Benchmarks: Cash Purchase, Fair Market Value, and Prepaid Lease Transaction Prices

The price of photovoltaic (PV) systems in the United States (i.e., the cost to the system owner) has dropped precipitously in recent years, led by substantial reductions in global PV module prices. This report provides a Q4 2013 update for residential PV systems, based on an objective methodology that closely approximates the book value of a PV system. Several cases are benchmarked to represent common variation in business models, labor rates, and module choice. We estimate a weighted-average cash purchase price of $3.29/W for modeled standard-efficiency, polycrystalline-silicon residential PV systems installed in the United States. This is a 46% decline from the 2013-dollar-adjusted price reported in the Q4 2010 benchmark report. In addition, this report frames the cash purchase price in the context of key price metrics relevant to the continually evolving landscape of third-party-owned PV systems by benchmarking the minimum sustainable lease price and the fair market value of residential PV systems.

14 SOLAR ENERGY↗

Moisture Management for High R-Value Walls

This report explains the moisture-related concerns for high R-value wall assemblies and discusses past Building America research work that informs this study. In this project, hygrothermal simulations were prepared for several common approaches to High R-value wall construction in six cities (Houston, Atlanta, Seattle, St. Louis, Chicago, and International Falls) representing a range of climate zones. The modeling program assessed the moisture durability of the wall assemblies based on three primary sources of moisture: construction moisture, air leakage condensation, and bulk water leakage; the report presents results of the study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Endogenous Assessment of the Capacity Value of Solar PV in Generation Investment Planning Studies. Draft

There exist several different reliability- and approximation-based methods to determine the capacity contribution of solar resources towards resource adequacy. However, most of these approaches require knowing in advance the installed capacities of both conventional and solar generators. This is a complication since generator capacities are actually decision variables in capacity planning studies. In this article we study the effect of time resolution and solar PV penetration using a capacity planning model that accounts for the full distribution of generator outages and solar resource variability. We also describe a modification of a standard deterministic planning model that enforces a resource adequacy target through a reserve margin constraint. Our numerical experiments show that at least 50 days worth of data are necessary to approximate the results of the full-resolution model with a maximum error of 2.5% on costs and capacity. We also show that the amount of displaced capacity of conventional generation decreases rapidly as the penetration of solar PV increases. We find that using an exogenously defined and constant capacity factor based on time-series data can yield relatively accurate results for small penetration levels (less than 5%). For higher penetration levels (up to 20%), the modified deterministic planning model better captures avoided costs and the decreasing value of solar PV. Although our results are not general, they highlight the importance of accounting for the variation in both energy and capacity value of solar resources endogenously in capacity planning models. A11 numerical experiments are performed using the IEEE Reliability Test System and 7 years worth of demand and solar data from a utility in Arizona.

14 SOLAR ENERGY↗

R-Value Measurements Performed on Uranium Targets Irradiated with Fission Spectrum Neutrons FY 2021 for F2019 Project

The separation and characterization of two irradiated uranium targets, a depleted uranium (DU) and a highly enriched uranium (HEU) target, was conducted in April of 2021. The two targets were assembled at Los Alamos National Laboratory (LANL) and irradiated using the critical assembly at the National Criticality Experiments Research Center (NCERC). Splits of the dissolved targets were received by Pacific Northwest National Laboratory (PNNL) after which the PNNL and LANL teams chemically separated the solutions using independent separation schemes and analyzed the separated fractions for short lived actinides and fission products. Chemical separations at PNNL were traced with stable or radioactive tracers to allow for the determination of chemical yields, analyzing using either inductively coupled plasma optical emission spectroscopy (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS) or gamma emission analysis (GEA) depending on the nature of the tracer. Several other analytical techniques were used by PNNL including kinetic phosphorescence analysis (KPA) and thermal ionization mass spectrometry (TIMS) depending on the analyte’s need. Comparisons were made between current and historical PNNL and LANL, as well as literature values. Overall, there was agreement between the two laboratories for the bulk of analytes, with some notable exceptions such as 111 Ag, and 141,143,144 Ce. Included in these comparisons were the short-lived actinides 237 U, 239 Np, the fission products 89 Sr, 91 Y, 95/97 Zr, 99 Mo, 111 Ag, 115/115 mCd, 136/137 Cs, 140 Ba, 141/143/144 Ce, 147 Nd, 153 Sm, 156 Eu, and 161 Tb, providing both total atoms as well as the R-values. The data presented in this report represents the sixth NCERC irradiation of HEU and DU (FY13, FY14, FY15, FY17, FY18, FY21), and their subsequent separation and analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Value Proposition for Cost-Effective, Demand Responsive-Enabling, Nonresidential Lighting System Retrofits in California Buildings

Commercial lighting represents a significant potential source of demand response (DR) for the electrical grid, via traditional load shedding and rapid-dispatch (fast-DR) ancillary services when DR is enabled by networked lighting controls (NLCs). However, despite the significant opportunity and a regulatory push, DR-enabled lighting is installed in relatively few buildings because most building owners do not recognize its strong value proposition. Although NLCs can reduce energy bills, optimize facilities, and increase revenue, these co-benefits are not well quantified. This project analyzed lighting DR resources and energy-related co-benefits for commercial buildings in California. Using more than 100,000 individual hourly load profiles, the team forecasted the potential DR resources likely available from commercial lighting in 2025 and estimated revenues available from participation of these DR resources in energy markets. Combining these results with field-study estimates for NLC installation costs and energy savings provided a detailed accounting of site-level cost and energy-related co-benefits by building type from NLC’s DR enablement. In many cases, energy savings alone can deliver significant net value, justifying NLC DR-enabled adoption. Additionally, the study considers the sometimes-larger non-energy benefits (NEBs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Highly Insulating Windows with a U-value less than 0.6 W/m2K

U.S. households rely primarily on three sources of energy: natural gas, electricity, and fuel oil. In the past several decades, electricity consumption by households has grown dramatically, and a significant portion of electricity used in homes is for lighting. Lighting includes both indoor and outdoor lighting and is found in virtually every household in the United States. In 2001, according to the US Energy Information Administration, lighting accounted for 101 billion kWh (8.8 percent) of U.S. household electricity use. Incandescent lamps, which are commonly found in households, are highly inefficient sources of light because about 90 percent of the energy used is lost as heat. For that reason, lighting has been one focus area to increase the efficiency of household electricity consumption. Windows have several functions, and one of the main functions is to provide a view to the outside. Daylighting is another one of windows main functions and determines the distribution of daylight to a space. Daylighting windows do not need to be transparent, and a translucent daylighting window is sufficient, and often desired, to diffuse the light and make the space more environmentally pleasing. In homes, skylights are one source of daylighting, but skylights are not very energy efficient and are inseparably linked to solar heat gain. In some climates, added solar heat gains from daylighting may be welcome; but in other climates, heat gain must be controlled. More energy efficient skylights and daylighting solutions, in general, are desired and can be designed by insulating them with aerogels. Aerogels are a highly insulating and transparent material in its pure form. The overall objective for this project was to prepare an economical, translucent, fiber-reinforced aerogel insulation material for daylighting applications that is durable for manufacturing purposes. This advanced insulation material will increase the thermal performance of daylighting windows, while satisfying constraints such as durability, cost, user acceptance, size limits, and environmental safety concerns. The energy efficient daylighting window will consist of a translucent and resilient aerogel panel sandwiched between glass panes in double glazed windows. Compared to the best windows available today, the double glazed translucent windows with 1/2-inch aerogel inserts will have a U-value of 1.2 W/m{sup 2} K (0.211 BTU/ft{sup 2} h F) without any coating or low conductivity fill gases. These windows will be more effective than the windows with an Energy Star rating of U-2 W/m{sup 2} K and could be made even more efficient by using low-e coated glass glazings and inert gas fills. This report summarizes the work accomplished on Cooperative Agreement DE-FC26-03NT41950. During this project, Aspen Aerogels made transparent and translucent aerogels from TMOS and TEOS. We characterized the transparency of the aerogels, reinforced the transparent aerogels with fibers and prepared large translucent aerogel panels and blankets. We also conducted an initial market study for energy efficient translucent windows. A lab-scale process was developed that could be scaled-up to manufacture blankets of these translucent aerogels. The large blankets prepared were used to fabricate prototype translucent windows and skylights. The primary goal of this project was to develop transparent, resilient, hydrophobic silica aerogels that have low thermal conductivities (R-10/inch) to be used to produce aerogel insulated double-glazing windows with a U value of 0.6 W/m{sup 2}K. To meet this objective we developed a process and equipment to produce blankets of translucent, hydrophobic aerogel. We focused on silica, organically-modified silica aerogels (Ormosils), and fiber reinforced silica aerogels due to the appreciable expertise in silica sol-gel processing available with the personnel at Aspen Aerogels, and also due to the quantity of knowledge available in the scientific literature. The project was conducted in three budget periods, herein called BP1, BP2 and BP3.

02 PETROLEUM↗

Automated Demand Response: The Missing Link in the Electricity Value Chain

In 2006, the Public Interest Energy Research Program (PIER) Demand Response Research Center (DRRC) at Lawrence Berkeley National Laboratory initiated research into Automated Demand Response (OpenADR) applications in California industry. The goal is to improve electric grid reliability and lower electricity use during periods of peak demand. The purpose of this research is to begin to define the relationship among a portfolio of actions that industrial facilities can undertake relative to their electricity use. This ?electricity value chain? defines energy management and demand response (DR) at six levels of service, distinguished by the magnitude, type, and rapidity of response. One element in the electricity supply chain is OpenADR, an open-standards based communications system to send signals to customers to allow them to manage their electric demand in response to supply conditions, such as prices or reliability, through a set of standard, open communications. Initial DRRC research suggests that industrial facilities that have undertaken energy efficiency measures are probably more, not less, likely to initiate other actions within this value chain such as daily load management and demand response. Moreover, OpenADR appears to afford some facilities the opportunity to develop the supporting control structure and to"demo" potential reductions in energy use that can later be applied to either more effective load management or a permanent reduction in use via energy efficiency. Under the right conditions, some types of industrial facilities can shift or shed loads, without any, or minimal disruption to operations, to protect their energy supply reliability and to take advantage of financial incentives.1 In 2007 and 2008, 35 industrial facilities agreed to implement OpenADR, representing a total capacity of nearly 40 MW. This paper describes how integrated or centralized demand management and system-level network controls are linked to OpenADR systems. Case studies of refrigerated warehouses and wastewater treatment facilities are used to illustrate OpenADR load reduction potential. Typical shed and shift strategies include: turning off or operating compressors, aerator blowers and pumps at reduced capacity, increasing temperature set-points or pre-cooling cold storage areas and over-oxygenating stored wastewater prior to a DR event. This study concludes that understanding industrial end-use processes and control capabilities is a key to support reduced service during DR events and these capabilities, if DR enabled, hold significant promise in reducing the electricity demand of the industrial sector during utility peak periods.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Generalized Energy-Dependent Q Values for Fission

We extend Madland's parameterization of the energy release in fission to obtain the dependence of the fission Q value for major and minor actinides on the incident neutron energies in the range 0 {le} E{sub n} {le} 20 MeV. Our parameterization is based on the actinide evaluations recommended for the ENDF/B-VII.1 release. This paper describes the calculation of energydependent fission Q values based on the calculation of the prompt energy release in fission by Madland. This calculation was adopted for use in the LLNL ENDL database and then generalized to obtain the prompt fission energy release for all actinides. Here the calculation is further generalized to the total energy release in fission. There are several stages in a fission event, depending on the time scale. Neutrons and gammas may be emitted at any time during the fission event.While our discussion here is focussed on compound nucleus creation by an incident neutron, similar parameterizations could be obtained for incident gammas or spontaneous fission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Extreme Value Analysis of Tidal Stream Velocity Perturbations

This paper presents a statistical extreme value analysis of maximum velocity perturbations from the mean flow speed in a tidal stream. This study was performed using tidal velocity data measured using both an Acoustic Doppler Velocimeter (ADV) and an Acoustic Doppler Current Profiler (ADCP) at the same location which allows for direct comparison of predictions. The extreme value analysis implements of a Peak-Over-Threshold method to explore the effect of perturbation length and time scale on the magnitude of a 50-year perturbation.

99 GENERAL AND MISCELLANEOUS↗

Summary of: Simulating the Value of Concentrating Solar Power with Thermal Energy Storage in a Production Cost Model (Presentation)

Concentrating solar power (CSP) deployed with thermal energy storage (TES) provides a dispatchable source of renewable energy. The value of CSP with TES, as with other potential generation resources, needs to be established using traditional utility planning tools. Production cost models, which simulate the operation of grid, are often used to estimate the operational value of different generation mixes. CSP with TES has historically had limited analysis in commercial production simulations. This document describes the implementation of CSP with TES in a commercial production cost model. It also describes the simulation of grid operations with CSP in a test system consisting of two balancing areas located primarily in Colorado.

14 SOLAR ENERGY↗

Drivers for the Value of Demand Response under Increased Levels of Wind and Solar Power; NREL (National Renewable Energy Laboratory)

Demand response may be a valuable flexible resource for low-carbon electric power grids. However, there are as many types of possible demand response as there are ways to use electricity, making demand response difficult to study at scale in realistic settings. This talk reviews our state of knowledge regarding the potential value of demand response in several example systems as a function of increasing levels of wind and solar power, sometimes drawing on the analogy between demand response and storage. Overall, we find demand response to be promising, but its potential value is very system dependent. Furthermore, demand response, like storage, can easily saturate ancillary service markets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Value-Added Process Intensification in the Supply Chain

The project goal is to assess opportunities for value-adds in the supply chain through designing a feedstock logistics systems that uses moisture during the residence time in storage to protect and increase feedstock value.

09 BIOMASS FUELS↗

Briquetting characteristics of woody and herbaceous biomass blends: Impact on physical properties, chemical composition, and calorific value

Abstract Intercropping (or polyculture) is gaining a lot of interest as it increases yields, allows better utilization of resources (water and nutrients), and provides better land management. The objective of this study is to understand the briquetting characteristics of woody and herbaceous biomass blends, which might result from intercropping. Tests were conducted on blends of lodgepole pine, switchgrass, and corn stover biomass using three hammer mill screen sizes (i.e., 4.8, 12.7, and 19.05 mm), three blend moistures (12%, 15%, and 18%, w.b.), and two‐ and three‐blend ratios (i.e., 1:1 and 1:1:1) using a pilot‐scale hydraulic briquette press. The briquette properties, such as unit and bulk density, durability rating after 5 days of storage (as they tend to attain stable density), and the energy consumption of the process were measured. The results indicate that moisture content of 12% and 15% (w.b.) and smaller hammer mill screen size of 4.8 mm increased the unit and bulk densities to >750 and >430 kg/m 3 and moisture content (15% and 18% (w.b.)) and hammer mill screen size of 12.7 and 19.05 mm produced briquettes with durability rating values of >95%. The higher moisture content of 18% (w.b.) and the hammer mill screen size of 12.7 and 19.05 mm had the highest energy consumption. The proximate and ultimate analysis showed that energy content improved by blending lodgepole pine with both corn stover and switchgrass and also showed increased calorific value and reduced ash content. Scanning electron microscopy micrographs showed interlocking of particles and cracks in the briquettes. © 2020 Society of Chemical Industry and John Wiley & Sons, Ltd

Tumuluru, Jaya Shankar↗