Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ultrafast optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Redirection and reshaping of intense extreme-ultraviolet radiation

The goal to control short-wavelength radiation for the investigation and manipulation of ultrafast dynamics in quantum systems coevolves with the growing availability of extreme-ultraviolet (XUV) and x-ray sources from high-harmonic generation and free-electron lasers. Here, we present an XUV spatio-spectral phase modulator based on an intense XUV laser beam propagating through an optically thick resonant target, introducing dispersion profile variations around the resonance both perpendicular to and along the laser propagation direction. The resulting dipole radiation gets spectrally reshaped and becomes more divergent as compared to the original beam in the far field. As an experimental demonstration, the intense-XUV–induced double-peak off-axis structure in the far-field spectrum obtained at the Free-Electron Laser in Hamburg (FLASH) shows indications of the underlying XUV-driven Rabi dynamics and resonant pulse propagation effects. The presented work highlights a ubiquitous phenomenon occurring when an intense laser beam passes through a resonant medium.

He, Yu [Max-Planck-Institut für Kernphysik, Heidel↗

Ultrafast vertical photoconductive intrinsic diamond switch with high current (17.1 A at 1 kV)

Here, this Letter reports on a vertical, bulk-conducting photoconductive semiconductor switch (PCSS) fabricated on an intrinsic Type IIa single-crystal diamond substrate. Under near-bandgap excitation at 225 nm with a 20 μ J pulse, a strong photocurrent response of 17.1 A at 1 kV DC bias magnitude is obtained by (i) tuning the optical trigger wavelength to the “matched-absorption” window (224–235 nm) near the band edge, where the optical penetration depth becomes comparable to the 500 μ m substrate thickness, and (ii) choosing the bias polarity ensuring electron-dominant conduction, given that electrons have a higher mobility than holes in diamond. The PCSS has an area-normalized responsivity of 54.2 mA W −1 cm −2 and an effective on-resistance of 8.48 Ω, with a fast 90%–10% transient fall time of 25 ns, attributed to carrier sweep-out. These results support vertical, bulk-conducting intrinsic diamond PCSS as a promising platform for high-power optical switching and provide new insight into intrinsic photoconductivity in diamond.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accurate quantification of lattice temperature dynamics from ultrafast electron diffraction of single-crystal films using dynamical scattering simulations

In ultrafast electron diffraction (UED) experiments, accurate retrieval of time-resolved structural parameters, such as atomic coordinates and thermal displacement parameters, requires an accurate scattering model. Unfortunately, kinematical models are often inaccurate even for relativistic electron probes, especially for dense, oriented single crystals where strong channeling and multiple scattering effects are present. This article introduces and demonstrates dynamical scattering models tailored for quantitative analysis of UED experiments performed on single-crystal films. As a case study, we examine ultrafast laser heating of single-crystal gold films. Comparison of kinematical and dynamical models reveals the strong effects of dynamical scattering within nm-scale films and their dependence on sample topography and probe kinetic energy. Applying to UED experiments on an 11 nm thick film using 750 keV electron probe pulses, the dynamical models provide a tenfold improvement over a comparable kinematical model in matching the measured UED patterns. Also, the retrieved lattice temperature rise is in very good agreement with predictions based on previously measured optical constants of gold, whereas fitting the Debye–Waller factor retrieves values that are more than three times lower. Altogether, these results show the importance of a dynamical scattering theory for quantitative analysis of UED and demonstrate models that can be practically applied to single-crystal materials and heterostructures.

36 MATERIALS SCIENCE↗

Simultaneous bright- and dark-field X-ray microscopy at X-ray free electron lasers

Abstract The structures, strain fields, and defect distributions in solid materials underlie the mechanical and physical properties across numerous applications. Many modern microstructural microscopy tools characterize crystal grains, domains and defects required to map lattice distortions or deformation, but are limited to studies of the (near) surface. Generally speaking, such tools cannot probe the structural dynamics in a way that is representative of bulk behavior. Synchrotron X-ray diffraction based imaging has long mapped the deeply embedded structural elements, and with enhanced resolution, dark field X-ray microscopy (DFXM) can now map those features with the requisite nm-resolution. However, these techniques still suffer from the required integration times due to limitations from the source and optics. This work extends DFXM to X-ray free electron lasers, showing how the $$10^{12}$$ 10 12 photons per pulse available at these sources offer structural characterization down to 100 fs resolution (orders of magnitude faster than current synchrotron images). We introduce the XFEL DFXM setup with simultaneous bright field microscopy to probe density changes within the same volume. This work presents a comprehensive guide to the multi-modal ultrafast high-resolution X-ray microscope that we constructed and tested at two XFELs, and shows initial data demonstrating two timing strategies to study associated reversible or irreversible lattice dynamics.

47 OTHER INSTRUMENTATION↗

Uncovering extreme nonlinear dynamics in solids through time-domain field analysis

Time-domain analysis of harmonic fields with sub-cycle resolution is now experimentally viable due to the emergence of sensitive, on-chip techniques for petahertz-scale optical-field sampling. We demonstrate how such a time-domain, field-resolved analysis uncovers the extreme nonlinear electron dynamics responsible for high-harmonic generation within solids. Time-dependent density functional theory was used to simulate harmonic generation from a solid-state band-gap system driven by near- to mid-infrared waveforms. Particular attention was paid to regimes where both intraband and interband emission mechanisms play a critical role in shaping the nonlinear response. We show that a time-domain analysis of the harmonic radiation fields identifies the interplay between intra- and interband dynamical processes underlying the nonlinear light generation. With further analysis, we show that changes to the dominant emission regime can occur after only slight changes to the peak driving intensity and central driving wavelength. Furthermore, time-domain analysis of harmonic fields also reveals, for the first time, the possibility of rapid changes in the dominant emission mechanism within the temporal window of the driving pulse envelope. Finally, we examine the experimental viability of performing time-domain analysis of harmonic fields with sub-cycle resolution using realistic parameters.

74 ATOMIC AND MOLECULAR PHYSICS↗

Sub-two-cycle gigawatt-peak-power LWIR OPA for ultrafast nonlinear spectroscopy of condensed state materials

The application of high-power, few-cycle, long-wave infrared (LWIR, 8–20 µm) pulses in strong-field physics is largely unexplored due to the lack of suitable sources. However, the generation of intense pulses with >6 µm wavelength range is becoming increasingly feasible with the recent advances in high-power ultrashort lasers in the middle-infrared range that can serve as a pump for optical parametric amplifiers (OPA). Here we experimentally demonstrate the feasibility of this approach by building an OPA pumped at 2.4 µm that generates 93 µJ pulses at 9.5 µm, 1 kHz repetition rate with sub-two-cycle pulse duration, 1.6 GW peak power, and excellent beam quality. The results open a wide range of applications in attosecond physics (especially for studies of condensed phase samples), remote sensing, and biophotonics.

Leshchenko, Vyacheslav (ORCID:0000000199708559)↗

Photoconductive metasurface-based ultrafast device

A theoretically perfectly absorbing photoconductive all-dielectric metasurface is provided. This metasurface can improve the efficiency and performance of ultrafast photoconductive switches and detectors. In an embodiment, the metasurface is incorporated in photoconductive THz switches or detectors. In embodiments, the metasurface is constituted by a network of gallium arsenide resonators. Each resonator supports two degenerate and critically coupled magnetic dipole modes. Simultaneous excitation of these two modes leads to theoretically close-to-perfect optical absorption near the resonant wavelength.

Brener, Igal↗

Direct evidence of the dominant role of multiphoton permanent-dipole transitions in strong-field dissociation of NO 2 +

We study laser-induced dissociation of a metastable NO 2+ ion-beam target into N + +O + , focusing on the prominent contribution by molecules breaking parallel to the polarization at high peak laser intensity (~10 15 W/cm 2 ). Our experimental results and time-dependent Schrödinger equation calculations show that, contrary to commonly held intuition that electronic transitions always prevail, the dominant process underlying this highly aligned dissociation is a multiphoton permanent-dipole transition involving only the electronic ground state and leading to its vibrational continuum. Strong-field permanent-dipole transitions should thus be considered generally, as they may play a significant role in other heteronuclear molecules. Moreover, their role should only grow in importance for longer wavelengths, a trending direction in ultrafast laser studies.

74 ATOMIC AND MOLECULAR PHYSICS↗

Robust and ultrafast state preparation by ramping artificial gauge potentials

Abstract The implementation of static artificial magnetic fields in ultracold atomic systems has become a powerful tool, e.g. for simulating quantum-Hall physics with charge-neutral atoms. Taking an interacting bosonic flux ladder as a minimal model, we investigate protocols for adiabatic state preparation via magnetic flux ramps. Considering the fact that it is actually the artificial vector potential (in the form of Peierls phases) that can be experimentally engineered in optical lattices, rather than the magnetic field, we find that the time required for adiabatic state preparation dramatically depends on which pattern of Peierls phases is used. This can be understood intuitively by noting that different patterns of time-dependent Peierls phases that all give rise to the same magnetic field ramp, generally lead to different artificial electric fields during the ramp. As an intriguing result, we find that an optimal choice allows for preparing the ground state almost instantaneously in the non-interacting system, which can be related to the concept of counterdiabatic driving. Remarkably, we find extremely short preparation times also in the strongly-interacting regime. Our findings open new possibilities for robust state preparation in atomic quantum simulators.

Wang, Botao (ORCID:0000000282202452)↗

Energy-efficient pathway for selectively exciting solute molecules to high vibrational states via solvent vibration-polariton pumping

Abstract Selectively exciting target molecules to high vibrational states is inefficient in the liquid phase, which restricts the use of IR pumping to catalyze ground-state chemical reactions. Here, we demonstrate that this inefficiency can sometimes be solved by confining the liquid to an optical cavity under vibrational strong coupling conditions. For a liquid solution of 13 CO 2 solute in a 12 CO 2 solvent, cavity molecular dynamics simulations show that exciting a polariton (hybrid light-matter state) of the solvent with an intense laser pulse, under suitable resonant conditions, may lead to a very strong (>3 quanta) and ultrafast (<1 ps) excitation of the solute, even though the solvent ends up being barely excited. By contrast, outside a cavity the same input pulse fluence can excite the solute by only half a vibrational quantum and the selectivity of excitation is low. Our finding is robust under different cavity volumes, which may lead to observable cavity enhancement on IR photochemical reactions in Fabry–Pérot cavities.

74 ATOMIC AND MOLECULAR PHYSICS↗

Polariton enhanced free charge carrier generation in donor–acceptor cavity systems by a second-hybridization mechanism

Cavity quantum electrodynamics has been studied as a potential approach to modify free charge carrier generation in donor–acceptor heterojunctions because of the delocalization and controllable energy level properties of hybridized light–matter states known as polaritons. However, in many experimental systems, cavity coupling decreases charge separation. In this work, we theoretically study the quantum dynamics of a coherent and dissipative donor–acceptor cavity system, to investigate the dynamical mechanism and further discover the conditions under which polaritons may enhance free charge carrier generation. We use open quantum system methods based on single-pulse pumping to find that polaritons have the potential to connect excitonic states and charge separated states, further enhancing free charge generation on an ultrafast timescale of several hundred femtoseconds. The mechanism involves polaritons with optimal energy levels that allow the exciton to overcome the high Coulomb barrier induced by electron–hole attraction. Moreover, we propose that a second-hybridization between a polariton state and dark states with similar energy enables the formation of the hybrid charge separated states that are optically active. These two mechanisms lead to a maximum of 50% enhancement of free charge carrier generation on a short timescale. However, our simulation reveals that on the longer timescale of picoseconds, internal conversion and cavity loss dominate and suppress free charge carrier generation, reproducing the experimental results. Thus, our work shows that polaritons can affect the charge separation mechanism and promote free charge carrier generation efficiency, but predominantly on a short timescale after photoexcitation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast Laser Material Damage Simulation—A New Look at an Old Problem

The chirped pulse amplification technique has enabled the generation of pulses of a few femtosecond duration with peak powers multi-Tera and Peta–Watt in the near infrared. Its implementation to realize even shorter pulse duration, higher energy, and higher repetition rate laser systems relies on overcoming the limitations imposed by laser damage of critical components. In particular, the laser damage of coatings in the amplifiers and in post-compression optics have become a bottleneck. The robustness of optical coatings is typically evaluated numerically through steady-state simulations of electric field enhancement in multilayer stacks. However, this approach cannot capture crucial characteristics of femtosecond laser induced damage (LID), as it only considers the geometry of the multilayer stack and the optical properties of the materials composing the stack. This approach neglects that in the interaction of an ultrashort pulse and the materials there is plasma generation and associated material modifications. Here, we present a numerical approach to estimate the LID threshold of dielectric multilayer coatings based on strong field electronic dynamics. In this dynamic scheme, the electric field propagation, photoionization, impact ionization, and electron heating are incorporated through a finite-difference time-domain algorithm. We applied our method to simulate the LID threshold of bulk fused silica, and of multilayer dielectric mirrors and gratings. The results are then compared with experimental measurements. The salient aspects of our model, such as the implementation of the Keldysh photoionization model, the impact ionization model, the electron collision model for ‘low’-temperature, dense plasma, and the LID threshold criterion for few-cycle pulses are discussed.

36 MATERIALS SCIENCE↗

Static characterization of a highly optimized streak tube design incorporating a steering slot anode and an aberration-corrected Einzel lens

The BHx streak tube, under development at the Laboratory for Laser Energetics, incorporates a series of novel electron-optics elements to enable high fidelity measurements for high-energy-density physics experiments. The system is engineered to support a 25-mm active photocathode region compatible with sub-picosecond temporal resolution and with 70% internal photoelectron throughput. It exhibits negligible geometric distortion on a flat output screen, making it well suited for variety of measurements, such as ultrafast x-ray spectroscopy. Here, this paper presents characterization data from a prototype unit tested with an ultraviolet laser in a static deflection (non-swept) mode and shows good agreement with the predictions from numerical modeling, including focusing performance and geometric distortion measurements. Key design elements have been demonstrated and de-risked, laying the foundation for dynamic deflection testing. The anticipated improvements in data fidelity are expected to impact the fields as diverse as inertial confinement fusion, laboratory astrophysics, and materials science.

High energy density physics↗

Speckle correlation as a monitor of X-ray free-electron laser induced crystal lattice deformation

X-ray free-electron lasers (X-FELs) present new opportunities to study ultrafast lattice dynamics in complex materials. While the unprecedented source brilliance enables high fidelity measurement of structural dynamics, it also raises experimental challenges related to the understanding and control of beam-induced irreversible structural changes in samples that can ultimately impact the interpretation of experimental results. This is also important for designing reliable high performance X-ray optical components. In this work, X-FEL beam-induced lattice alterations are investigated by measuring the shot-to-shot evolution of near-Bragg coherent scattering from a single crystalline germanium sample. It is shown that X-ray photon correlation analysis of sequential speckle patterns measurements can be used to monitor the nature and extent of lattice rearrangements. Additionally, abrupt, irreversible changes are observed following intermittent high-fluence monochromatic X-ray pulses, thus revealing the existence of a threshold response to X-FEL pulse intensity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Highly Conjugated Porphyrin Arrays Enable Optical Resolution of Ferromagnetic and Antiferromagnetic Aligned States of the Triplet Exciton and an Incorporated Stable Radical

Well-defined photogenerated molecular spin systems have potential utility in spintronics and quantum information science (QIS). Because molecular magnetic, optical, and electronic properties can be controlled by design, diverse spin systems can be prepared at modest temperatures. Photogenerated molecular spin systems often involve states prepared from the interaction of excitons and charges. Resolving the nature of electron spin alignment in photogenerated spin states described by the coupling of a triplet exciton and a stable radical commonly relies on EPR spectroscopy. Here, we describe ethyne-bridged (porphinato)metal ( PM n ) oligomers that incorporate a macrocycle-bound Cu(II) radical center. Upon photoexcitation of such PM n arrays, a singdoublet ( 2 S 1 ) state is formed; ultrafast internal conversion (IC) then produces a tripdoublet ( 2 T 1 ) state, which undergoes intersystem crossing (ISC) to produce a tripquartet ( 4 T 1 ) state, before relaxation to the ground state ( 2 S 0 ). These highly conjugated Cu(II) radical-containing PMn arrays enable direct observation of copper porphyrin 2 T 1 → 4 T 1 ISC dynamics from the biexponential decay of the near-infrared (NIR) 2,4 T 1 → 2,4 T n transient absorption manifold. Multireference n-electron valence perturbation theory (NEVPT2) computations illuminate how PM n electronic structure controls the relaxation dynamics of these long-lived (>10 ns) electronically excited multiplet states. These studies show that highly conjugated and polarizable porphyrin arrays incorporating stable spin centers provide rare π-delocalized systems where the ferromagnetic and antiferromagnetic alignment between a triplet exciton and a stable radical are both spectrally resolved and addressable using transient optical spectroscopy at wavelengths exceeding 1 μm, providing new opportunities to QIS.

14 SOLAR ENERGY↗

A Quantitative Method for In Situ Pump-Beam Metrology in 4D Ultrafast Electron Microscopy

In this work, we report a method for measuring spot size and focusing conditions of the femtosecond (fs) excitation laser in situ at the specimen location in 4D ultrafast electron microscopy (UEM). The method makes use of threshold laser ablation behaviors of thin amorphous carbon membranes. For Gaussian beam profiles and for ablation threshold fluence values, we analytically derive expressions describing the relationship between ablated hole size and the actual laser spot size. Using these expressions, we developed experimental procedures for characterizing the shape and spot size of the pump beam at the specimen. We demonstrate the viability of the approach for incident excitation wavelengths of 343 nm and 515 nm, thus illustrating the applicability of the method to a range of optical wavelengths without modification. Further, we show that by measuring ablated hole size as a function of focusing condition, a full metrological characterization of the Gaussian beam propagation properties can be performed. Finally, we find good agreement for spot sizes determined with this method and with those determined by extrapolation from measurements taken outside the microscope column. Overall, this method is a simple, cost-effective means for accurate and precise determination of key pump-beam parameters in situ at the specimen location in UEM experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗