Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transport models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Intrinsic rotation modulation by diffusive neutral particles in tokamaks

Abstract The modulated transport model, a model kinetic ion transport equation for the pedestal and scrape-off layer (SOL), is generalized to self-consistently include effects of a single neutral particle species. The neutrals contribute additional transport terms, modifying the v ∥ -dependent orbit-averaged ion diffusivities of the original work and the resulting predicted intrinsic rotation of the ions. After making simplifying assumptions of the neutral transport, in particular taking the continuous transport limit via a short charge-exchange step expansion, we derive relatively simple analytic expressions that capture the diffusive neutral physics. Within the scope of the model’s validity, the neutral-driven intrinsic rotation can compete with the turbulence-driven intrinsic rotation. However, for physically motivated parameters, the neutral-driven intrinsic rotation appears negligible, either on a term-by-term basis or due to a strong cancellation between the neutral-driven momentum diffusion and pinch terms. It appears that a treatment containing finite charge-exchange steps is necessary to capture neutral transport of strong flow momentum into the confined region from the SOL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microtearing instabilities and electron thermal transport in low and high collisionality NSTX discharges

Microtearing mode (MTM) real frequency, growth rate, magnetic fluctuation amplitude and resulting electron thermal transport are studied in systematic NSTX scans of relevant plasma parameters. Here, the dependency of the MTM real frequency and growth rate on plasma parameters, suitable for low and high collision NSTX discharges, is obtained by using the reduced MTM transport model. The plasma parameter dependencies are compared and found to be consistent with the results obtained from MTM using the Gyrokinetic GYRO code. The scaling trend of collision frequency and plasma beta is found to be consistent with the global energy confinement trend observed in the NSTX experiment. The strength of the magnetic fluctuation is found to be consistent with the gyrokinetic estimate. In earlier studies, it was found that the version of the Multi-Mode (MM) anomalous transport model, which did not contain the effect of MTMs, provided an appropriate description of the electron temperature profiles in standard tokamak discharges and not in spherical tokamaks. When the MM model, which involves transport associated with MTMs, is incorporated in the TRANSP code and is used in the study of electron thermal transport in NSTX discharges, it is observed that the agreement with the experimental electron temperature profile is substantially improved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microtearing Instabilities and Electron Thermal Transport in Low and High Collisionality NSTX Discharges

Microtearing mode (MTM) real frequency, growth rate, magnetic fluctuation amplitude and resulting electron thermal transport are studied in systematic NSTX scans of relevant plasma parameters. The dependency of the MTM real frequency and growth rate on plasma parameters, suitable for low and high collision NSTX discharges, is obtained by using the reduced MTM transport model [T. Rafiq, et al., Phys. Plasmas 23, 062507 (2016)]. The plasma parameter dependencies are compared and found to be consistent with the results obtained from MTM using the Gyrokinetic GYRO code. The scaling trend of collision frequency and plasma beta is found to be consistent with the global energy confinement trend observed in the NSTX experiment. The strength of the magnetic fluctuation is found to be consistent with the gyrokinetic estimate.In earlier studies, it was found that the version of the Multi-Mode (MM) anomalous transport model, which did not contain the effect of MTMs, provided an appropriate description of the electron temperature profiles in standard tokamak discharges and not in spherical tokamaks. When the MM model, which involves transport associated with MTMs, is incorporated in the TRANSP code and is used in the study of electron thermal transport in NSTX discharges, it is observed that the agreement with the experimental electron temperature profile is substantially improved.

fusion plasma technology↗

Observational constraints on interchange models at Jupiter

Data from the Voyager plasma science instrument are used to set limits on transport models for the inner Jovian magnetosphere. The instrument has an effective time resolution for detecting changes in density of 0.24 s, which corresopnds to a spatial resolution of about 20 km (equal to the gyroradius of an oxygen ion) in the region just outside of Io. This resolution enables an upper limit of about 10 percent to be set on changes in density between adjacent magnetic flux tubes, which rules out transport models which invoke inward motion of near empty flux tubes to replace outward-moving flux tubes carrying Iogenic plasma.

Richardson, John D.↗

Evaluation of Modeling NO2 Concentrations Driven by Satellite-Derived and Bottom-Up Emission Inventories Using In-Situ Measurements Over China

Chemical transport models together with emission inventories are widely used to simulate NO2 concentrations over China, but validation of the simulations with in situ measurements has been extremely limited. Here we use ground measurements obtained from the air quality monitoring network recently developed by the Ministry of Environmental Protection of China to validate modeling surface NO2 concentrations from the CHIMERE regional chemical transport model driven by the satellite-derived DECSO and the bottom-up MIX emission inventories. We applied a correction factor to the observations to account for the interferences of other oxidized nitrogen compounds (NOz), based on the modeled ratio of NO2 to NOz. The model accurately reproduces the spatial variability in NO2 from in situ measurements, with a spatial correlation coefficient of over 0.7 for simulations based on both inventories. A negative and positive bias is found for the simulation with the DECSO (slopeD0.74 and 0.64 for the daily mean and daytime only) and the MIX (slopeD1.3 and 1.1) inventories, respectively, suggesting an underestimation and overestimation of NOx emissions from corresponding inventories. The bias between observed and modeled concentrations is reduced, with the slope dropping from 1.3 to 1.0 when the spatial distribution of NOx emissions in the DECSO inventory is applied as the spatial proxy for the MIX inventory, which suggests an improvement of the distribution of emissions between urban and suburban or rural areas in the DECSO inventory compared to that used in the bottom-up inventory. A rough estimate indicates that the observed concentrations, from sites predominantly placed in the populated urban areas, may be 10-40% higher than the corresponding model grid cell mean. This reduces the estimate of the negative bias of the DECSO-based simulation to the range of -30 to 0% on average and more firmly establishes that the MIX inventory is biased high over major cities. The performance of the model is comparable over seasons, with a slightly worse spatial correlation in summer due to the difficulties in resolving the more active NOx photochemistry and larger concentration gradients in summer by the model. In addition, the model well captures the daytime diurnal cycle but shows more significant disagreement between simulations and measurements during nighttime, which likely produces a positive model bias of about 15% in the daily mean concentrations. This is most likely related to the uncertainty in vertical mixing in the model at night.

NO2 modelling↗

Quantifying the Causes of Differences in Tropospheric OH Within Global Models

The hydroxyl radical (OH) is the primary daytime oxidant in the troposphere and provides the main loss mechanism for many pollutants and greenhouse gases, including methane (CH4). Global mean tropospheric OH differs by as much as 80% among various global models, for reasons that are not well understood. We use neural networks (NNs), trained using archived output from eight chemical transport models (CTMs) that participated in the Polar Study using Aircraft, Remote Sensing, Surface Measurements and Models, of Climate, Chemistry, Aerosols and Transport Model Intercomparison Project (POLMIP), to quantify the factors responsible for differences in tropospheric OH and resulting CH4 lifetime (Tau CH4) between these models. Annual average Tau CH4, for loss by OH only, ranges from 8.0 to 11.6 years for the eight POLMIP CTMs. The factors driving these differences were quantified by inputting 3-D chemical fields from one CTM into the trained NN of another CTM. Across all CTMs, the largest mean differences in Tau CH4 (Delta Tau CH4) result from variations in chemical mechanisms (Delta Tau CH4 = 0.46 years), the photolysis frequency (J) of O3 yields O(D-1) (0.31 years), local O3 (0.30 years), and CO (0.23 years). The Delta Tau CH4 due to CTM differences in NO(x) (NO + NO2) is relatively low (0.17 years), although large regional variation in OH between the CTMs is attributed to NO(x). Differences in isoprene and J(NO2) have negligible overall effect on globally averaged tropospheric OH, although the extent of OH variations due to each factor depends on the model being examined. This study demonstrates that NNs can serve as a useful tool for quantifying why tropospheric OH varies between global models, provided that essential chemical fields are archived.

Surface Measurements and Models↗

Assessment of tritium effluent from Prototype Generation IV Sodium-cooled Fast Reactor

We report a tritium transport model for a pool-type sodium cooled fast reactor was developed for estimation of tritium effluents from the Prototype Generation IV Sodium-cooled Fast Reactor (PGSFR). For this purpose, the transport model developed for Experimental Breeder Reactor II and Fast Flux Test Facility was updated and validated. The tritium production rate from ternary fission and activations in PGSFR were calculated by the Argonne Reactor Computation (ARC) code suite for fast reactor analysis, and due to the potential uncertainties in source terms and variations of cold trap performance and material permeability during reactor operation, the tritium distributions and tritium effluents were estimated for several bounding cases. The upper bounding gaseous and liquid tritium release rates from PGSFR are similar to ~440.7 Ci/year and 14.7 Ci/year, respectively. The gaseous tritium effluent is about few orders of magnitude smaller than the regulatory constraint of the tritium concentration in the air. The peak tritium concentration in the steam-generator feedwater is similar to ~1.1x10 -3 mu Ci/g, which is required to be diluted prior to releasing as tritiated water. The accumulated tritium in the cold trap after five cycle operations is ~ 52,000 Ci. Because of significant conservatism in these upper bounding estimations, it is expected that the tritium effluent at the nominal case with plausible source terms would be about 2 orders of magnitude smaller than that of the upper bounding case.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluating nonlocal heat transport in directly driven chromium spheres using x-ray spectroscopy

We report on experiments investigating heat transport in laser-generated plasmas using directly driven chromium spheres. The spheres are fielded at the OMEGA laser facility and are driven with laser intensities of 5×10 14 Wcm −2 . Plasma conditions in the corona and scattered light are measured experimentally and compared against predictions from two-dimensional (2D) radiation-hydrodynamic simulations using different heat transport models. Spectroscopic analysis of x-ray self-emission is used as an additional diagnostic. X-ray emission is integrated over a large region of the plasma, probing regions that are not observed by localized optical Thomson scattering. In particular, x-ray emission peaks near the plasma critical density, so emission from optically thin lines provides information on plasma conditions where nonlocal transport is most likely to be significant. Three common heat transport models are considered: local transport with flux limiters f = 0.15 and f = 0.03, and the nonlocal Schurtz–Nicolai–Busquet (SNB) model. Consistent with previous work, both the high-flux (f = 0.15) and SNB models show good agreement with experimentally measured plasma conditions in the corona despite overpredicting laser absorption, whereas the low-flux (f = 0.03) model fails to match any experimental data. Conditions inferred from x-ray self-emission line ratios support this conclusion during the period of laser peak power, although synthetic spectra for all models fail to match the experiment during the transient portions of the pulse. For these reasons, the low-flux model is again rejected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Position-specific isotope effects during alkaline hydrolysis of 2,4-dinitroanisole resolved by compound-specific isotope analysis, 13 C NMR, and density-functional theory

Compound-specific isotope analysis (CSIA), position-specific isotope analysis (PSIA), and computational modeling (e.g., quantum mechanical models; reactive-transport models) are increasingly being used to monitor and predict biotic and abiotic transformations of organic contaminants in the field. However, identifying the isotope effect(s) associated with a specific transformation remains challenging in many cases. We describe and interpret the position-specific isotope effects of C and N associated with a SN 2 Ar reaction mechanism by a combination of CSIA and PSIA using quantitative 13 C nuclear magnetic resonance spectrometry, and density-functional theory, using 2,4-dinitroanisole (DNAN) as a model compound. The position-specific 13 C enrichment factor of O–C 1 bond at the methoxy group attachment site (ε C1 ) was found to be approximately -41‰, a diagnostic value for transformation of DNAN to its reaction products 2,4-dinitrophenol and methanol. Theoretical kinetic isotope effects calculated for DNAN isotopologues agreed well with the position-specific isotope effects measured by CSIA and PSIA. This combination of measurements and theoretical predictions demonstrates a useful tool for evaluating degradation efficiencies and/or mechanisms of organic contaminants and may promote new and improved applications of isotope analysis in laboratory and field investigations.

13C NMR↗

Cumulants and correlation functions of net-proton, proton, and antiproton multiplicity distributions in Au+Au collisions at energies available at the BNL Relativistic Heavy Ion Collider

Here, we report a systematic measurement of cumulants, C n , for net-proton, proton, and antiproton multiplicity distributions, and correlation functions, κ n , for proton and antiproton multiplicity distributions up to the fourth order in Au+Au collisions at $\sqrt{s_{NN}}$ = 7.7, 11.5, 14.5, 19.6, 27, 39, 54.4, 62.4, and 200 GeV. The C n and κ n are presented as a function of collision energy, centrality and kinematic acceptance in rapidity, y, and transverse momentum, p T . The data were taken during the first phase of the Beam Energy Scan (BES) program (2010–2017) at the BNL Relativistic Heavy Ion Collider (RHIC) facility. The measurements are carried out at midrapidity (|y| < 0.5) and transverse momentum 0.4 < p T < 2.0 GeV/c, using the STAR detector at RHIC. We observe a nonmonotonic energy dependence ($\sqrt{s_{NN}}$ = 7.7–62.4 GeV) of the net-proton C 4 /C 2 with the significance of 3.1σ for the 0–5% central Au+Au collisions. This is consistent with the expectations of critical fluctuations in a QCD-inspired model. Thermal and transport model calculations show a monotonic variation with $\sqrt{s_{NN}}$. For the multiparticle correlation functions, we observe significant negative values for a two-particle correlation function, κ 2 , of protons and antiprotons, which are mainly due to the effects of baryon number conservation. Furthermore, it is found that the four-particle correlation function, κ 4 , of protons plays a role in determining the energy dependence of proton C 4 /C 1 below 19.6 GeV, which cannot be understood by the effect of baryon number conservation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HdsaLib

HdsaLib performs hyper-differential sensitivity analysis in optimization problems that are constrained by partial differential equation problems. The software aids researchers in understanding the impact of uncertainties on their optimization models. The tool has been applied for use in ice sheet modeling, fluid flow modeling, atmospheric tracer transport modeling, and subsurface flow modeling. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

van Bloemen Waanders, Bart [Sandia National Lab. (↗

Contaminant Source Identification from Finite Sensor Data: Perron–Frobenius Operator and Bayesian Inference

Sensors in the built environment ensure safety and comfort by tracking contaminants in the occupied space. In the event of contaminant release, it is important to use the limited sensor data to rapidly and accurately identify the release location of the contaminant. Identification of the release location will enable subsequent remediation as well as evacuation decision-making. In previous work, we used an operator theoretic approach—based on the Perron–Frobenius (PF) operator—to estimate the contaminant concentration distribution in the domain given a finite amount of streaming sensor data. In the current work, the approach is extended to identify the most probable contaminant release location. The release location identification is framed as a Bayesian inference problem. The Bayesian inference approach requires considering multiple release location scenarios, which is done efficiently using the discrete PF operator. The discrete PF operator provides a fast, effective and accurate model for contaminant transport modeling. The utility of our PF-based Bayesian inference methodology is illustrated using single-point release scenarios in both two and three-dimensional cases. The method provides a fast, accurate, and efficient framework for real-time identification of contaminant source location.

42 ENGINEERING↗

Constraints on the development of the early continental crust from isotopic data

Aspects of the origin and development of the early (AE) continential crust are addressed by radiogenic isotope and trace element studies. The most important ones are: (1) at what time did the earliest continental crust form; (2) what was its composition; (3) by what processes did it grow and by what processes was it destroyed; (4) what were the rates of production and destruction as a function of time during this time period? Nd is isotopic data on the oldest terrestrial rocks indicate that the mantle at this time had already suffered substantial depletion in incompatible elements due to earlier continent forming events. Isotopic data on young volcanic rocks derived from the depleted mantle show no evidence of this early history. The observed isotopic patterns of Nd, Sr, Hf and Pb through time together with the presently observed age spectrum of crustal rocks are considered. These patterns can be modelled by a transport model in which the continental growth and destruction rates are allowed to vary as a function of time. It is suggest that the mass of the continents at 3.8 AE ago was about 25% of the current continental mass. However, due to the very high recycling rates obtained in the early Archean only a few percent of this crust has been preserved up to the present.

Jacobson, S. B.↗

Analysis of MIR-18 results for physical and biological dosimetry: radiation shielding effectiveness in LEO

We compare models of radiation transport and biological response to physical and biological dosimetry results from astronauts on the Mir space station. Transport models are shown to be in good agreement with physical measurements and indicate that the ratio of equivalent dose from the Galactic Cosmic Rays (GCR) to protons is about 3/2:1 and that this ratio will increase for exposures to internal organs. Two biological response models are used to compare to the Mir biodosimetry for chromosome aberration in lymphocyte cells; a track-structure model and the linear-quadratic model with linear energy transfer (LET) dependent weighting coefficients. These models are fit to in vitro data for aberration formation in human lymphocytes by photons and charged particles. Both models are found to be in reasonable agreement with data for aberrations in lymphocytes of Mir crew members: however there are differences between the use of LET dependent weighting factors and track structure models for assigning radiation quality factors. The major difference in the models is the increased effectiveness predicted by the track model for low charge and energy ions with LET near 10 keV/micrometers. The results of our calculations indicate that aluminum shielding, although providing important mitigation of the effects of trapped radiation, provides no protective effect from the galactic cosmic rays (GCR) in low-earth orbit (LEO) using either equivalent dose or the number of chromosome aberrations as a measure until about 100 g/cm 2 of material is used.

Flight Experiment↗

The Carbon Monoxide Tape Recorder

Using Aura MLS data we have identified the stratospheric tape recorder in carbon monoxide (CO). Unlike the water vapor tape recorder, which is controlled by upper troposphere processes, the CO tape recorder is linked to seasonal biomass burning. Since CO has a lifetime of only a few months, the CO tape recorder barely extends above 20 km. The tape head for CO appears to be close to 360K near the same location as the water vapor tape head [Read et al, 20041. Both tape heads are below the equatorial cold point tropopause but above the base of the tropical tropopause layer. The tape recorder signal becomes more distinct from 360K to 380K suggesting that convective detrainment of plays a decreasingly important role with altitude. The Global Modeling Initiative chemical transport model forced by the climatology of biomass burning reproduces the CO tape recorder.

Schoeberl, M. R.↗

Forecast, Measurement, and Modeling of an Unprecedented Polar Ozone Filament Event over Mauna Loa Observatory, Hawaii

In mid-March 2005 the northern lower stratospheric polar vortex experienced a severe stretching episode, bringing a large polar filament far south of Alaska toward Hawaii. This meridional intrusion of rare extent, coinciding with the polar vortex final warming and breakdown, was followed by a zonal stretching in the wake of the easterly propagating subtropical main flow. This caused polar air to remain over Hawaii for several days before diluting into the subtropics. After being successfully forecasted to pass over Hawaii by the high-resolution potential vorticity advection model Modele Isentrope du transport Meso-echelle de l'Ozone Stratospherique par Advection (MIMOSA), the filament was observed on isentropic surfaces between 415 K and 455 K (17-20 km) by the Jet Propulsion Laboratory stratospheric ozone lidar measurements at Mauna Loa Observatory, Hawaii, between 16 and 19 March 2005. It was materialized as a thin layer of enhanced ozone peaking at 1.6 ppmv in a region where the climatological values usually average 1.0 ppmv. These values were compared to those obtained by the three dimensional Chemistry-Transport Model MIMOSA-CHIM. Agreement between lidar and model was excellent, particularly in the similar appearance of the ozone peak near 435 K (18.5 km) on 16 March, and the persistence of this layer at higher isentropic levels for the following three days. Passive ozone, also modeled by MIMOSA-CHIM, was at about 3-4 ppmv inside the filament while above Hawaii. A detailed history of the modeled chemistry inside the filament suggests that the air mass was still polar ozone- depleted when passing over Hawaii. The filament quickly separated from the main vortex after its Hawaiian overpass. It never reconnected and, in less than 10 days, dispersed entirely in the subtropics.

atmospheric processes↗