Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

On the use of Lineal Energy Measurements to Estimate Linear Energy Transfer Spectra

This paper examines the error resulting from using a lineal energy spectrum to represent a linear energy transfer spectrum for applications in the space radiation environment. Lineal energy and linear energy transfer spectra are compared in three diverse but typical space radiation environments. Different detector geometries are also studied to determine how they affect the error. LET spectra are typically used to compute dose equivalent for radiation hazard estimation and single event effect rates to estimate radiation effects on electronics. The errors in the estimations of dose equivalent and single event rates that result from substituting lineal energy spectra for linear energy spectra are examined. It is found that this substitution has little effect on dose equivalent estimates in interplanetary quiet-time environment regardless of detector shape. The substitution has more of an effect when the environment is dominated by solar energetic particles or trapped radiation, but even then the errors are minor especially if a spherical detector is used. For single event estimation, the effect of the substitution can be large if the threshold for the single event effect is near where the linear energy spectrum drops suddenly. It is judged that single event rate estimates made from lineal energy spectra are unreliable and the use of lineal energy spectra for single event rate estimation should be avoided.

Adams, David A.↗

Radiation Design of Ion Mass Spectrometers

In the harsh radiation environment of Jupiter and with the JUpiter ICy moon Explorer (JUICE) mission including two Europa flybys where local intensities are approx. 150 krad/month behind 100 mils of Al shielding, so background from penetrating radiation can be a serious issue for detectors inside an Ion Mass Spectrometer (IMS). This can especially be important for minor ion detection designs. Detectors of choice for time-of-flight (TOF) designs are microchannel plates (MCP) and some designs may include solid state detectors (SSD). The standard approach is to use shielding designs so background event rates are low enough that the detector max rates and lifetimes are first not exceeded and then the more stringent requirement that the desired measurement can successfully be made (i.e., desired signal is sufficiently greater than background noise after background subtraction is made). GEANT codes are typically used along with various electronic techniques, but such designs need to know how the detectors will respond to the simulated primary and secondary radiations produced within the instrument. We will be presenting some preliminary measurements made on the response of MCPs to energetic electrons (20 ke V to 1400 ke V) using a Miniature TOF (MTOF) device and the High Energy Facility at Goddard Space Flight Center which has a Van de Graaff accelerator.

Sittler, Ed↗

SBND Calibration

The Short-Baseline Near Detector (SBND) is a 112-ton liquid argon time projection chamber (LArTPC) serving as the near detector of the Short-Baseline Neutrino Program at Fermilab. SBND aims to make precise measurements of neutrino-argon interactions, necessitating an extensive calibration program for the LArTPC to ensure precision/accuracy in these measurements. This talk describes the use of cosmogenic, radiogenic, and neutrino interaction activity with both Monte Carlo simulation and data in calibrating the SBND subsystems of the Time Projection Chamber, Photon Detection System, and Cosmic Ray Tagger. We will highlight some of SBND's first calibration results, including electronics calibrations, measurement of the electron lifetime, shower calibration, and studies of space charge effects in the detector.

Oh, Sungbin [Fermilab]↗

Photon-Counting Multikilohertz Microlaser Altimeters for Airborne and Spaceborne Topographic Measurements

We consider the optimum design of photon-counting microlaser altimeters operating from airborne and spaceborne platforms under both day and night conditions. Extremely compact Q-switched microlaser transmitters produce trains of low energy pulses at multi-kHz rates and can easily generate subnanosecond pulse-widths for precise ranging. To guide the design, we have modeled the solar noise background and developed simple algorithms, based on Post-Detection Poisson Filtering (PDPF), to optimally extract the weak altimeter signal from a high noise background during daytime operations. Practical technology issues, such as detector and/or receiver dead times, have also been considered in the analysis. We describe an airborne prototype, being developed under NASA's instrument Incubator Program, which is designed to operate at a 10 kHz rate from aircraft cruise altitudes up to 12 km with laser pulse energies on the order of a few microjoules. We also analyze a compact and power efficient system designed to operate from Mars orbit at an altitude of 300 km and sample the Martian surface at rates up to 4.3 kHz using a 1 watt laser transmitter and an 18 cm telescope. This yields a Power-Aperture Product of 0.24 W-square meter, corresponding to a value almost 4 times smaller than the Mars Orbiting Laser Altimeter (0. 88W-square meter), yet the sampling rate is roughly 400 times greater (4 kHz vs 10 Hz) Relative to conventional high power laser altimeters, advantages of photon-counting laser altimeters include: (1) a more efficient use of available laser photons providing up to two orders of magnitude greater surface sampling rates for a given laser power-telescope aperture product; (2) a simultaneous two order of magnitude reduction in the volume, cost and weight of the telescope system; (3) the unique ability to spatially resolve the source of the surface return in a photon counting mode through the use of pixellated or imaging detectors; and (4) improved vertical and transverse spatial resolution resulting from both (1) and (3). Furthermore, because of significantly lower laser pulse energies, the microaltimeter is inherently more eyesafe to observers on the ground and less prone to internal optical damage, which can terminate a space mission prematurely.

Degnan, John J.↗

Optical-pump–terahertz-probe spectroscopy in high magnetic fields with kHz single-shot detection

We demonstrate optical pump–THz probe (OPTP) spectroscopy with a variable external magnetic field (0–9 T), in which the time-dependent THz signal is measured by echelon-based single-shot detection at a repetition rate of 1 kHz. The method reduces data acquisition times by more than an order of magnitude compared to conventional electro-optic sampling using a scanning delay stage. The approach illustrates the wide applicability of the single-shot measurement approach to non-equilibrium systems that are studied through OPTP spectroscopy, especially in cases where parameters such as magnetic field strength (B) or other experimental parameters are varied. We demonstrate the capabilities of our measurement by performing cyclotron resonance experiments in bulk silicon, where we observe B-field-dependent carrier relaxation and distinct relaxation rates for different carrier types. We use a pair of economical linear array detectors to measure 500 time points on each shot, offering an equivalent performance to camera-based detection with possibilities for higher repetition rates.

Instruments & Instrumentation↗

Blocking Losses With a Photon Counter

It was not known how to assess accurately losses in a communications link due to photodetector blocking, a phenomenon wherein a detector is rendered inactive for a short time after the detection of a photon. When used to detect a communications signal, blocking leads to losses relative to an ideal detector, which may be measured as a reduction in the communications rate for a given received signal power, or an increase in the signal power required to support the same communications rate. This work involved characterizing blocking losses for single detectors and arrays of detectors. Blocking may be mitigated by spreading the signal intensity over an array of detectors, reducing the count rate on any one detector. A simple approximation was made to the blocking loss as a function of the probability that a detector is unblocked at a given time, essentially treating the blocking probability as a scaling of the detection efficiency. An exact statistical characterization was derived for a single detector, and an approximation for multiple detectors. This allowed derivation of several accurate approximations to the loss. Methods were also derived to account for a rise time in recovery, and non-uniform illumination due to diffraction and atmospheric distortion of the phase front. It was assumed that the communications signal is intensity modulated and received by an array of photon-counting photodetectors. For the purpose of this analysis, it was assumed that the detectors are ideal, in that they produce a signal that allows one to reproduce the arrival times of electrons, produced either as photoelectrons or from dark noise, exactly. For single detectors, the performance of the maximum-likelihood (ML) receiver in blocking is illustrated, as well as a maximum-count (MC) receiver, that, when receiving a pulse-position-modulated (PPM) signal, selects the symbol corresponding to the slot with the largest electron count. Whereas the MC receiver saturates at high count rates, the ML receiver may not. The loss in capacity, symbol-error-rate (SER), and count-rate were numerically computed. It was shown that the capacity and symbol-error-rate losses track, whereas the count-rate loss does not generally reflect the SER or capacity loss, as the slot-statistics at the detector output are no longer Poisson. It is also shown that the MC receiver loss may be accurately predicted for dead times on the order of a slot.

Moision, Burce E.↗

The South Pole Telescope AGN Monitoring Campaign: First Release of SPTpol Bright AGN Light Curves

The South Pole Telescope (SPT) collaboration has recently embarked upon a campaign to monitor the brightness of a sample of active galactic nuclei (AGN), both in real time and in archival SPT data. The original design of the SPT was optimized for observations of the cosmic microwave background (CMB) at arc-minute and larger angular scales, and it has been used for this purpose for nearly twenty years, using three generations of CMB cameras. Recently it has been recognized that data from CMB experiments have the potential to be used for AGN monitoring. In this paper, we present the first public release of data from a full sample of SPT-monitored AGN, comprising 158 AGN light curves and associated data from the SPTpol camera, which was operational from 2012-2016. These light curves were created using observations from the SPTpol 500 deg$^{2}$ survey, in which the instrument was used to scan a 500 deg$^2$ patch of the sky several times per day with detectors sensitive to radiation in bands centered at 90 and 150 GHz. We provide a comprehensive description of the observations, the data processing methods, and the resulting light curve catalog. As an example of analyses that these data enable, we searched for a correlation between variability and spectral index, and we looked for ``bluer-when-brighter'' trends in the sample. Our analysis finds $> 10 σ$ correlation between fractional intrinsic variance and mean spectral index in the sample, but no significant evidence for bluer-when-brighter trends. The datasets from this study can be accessed through the SPT Treasury Record of AGN With Historical Activity and Time-Series or STRAWHAT catalog. This initial data release includes SPTpol light curves at 90 and 150 GHz, focusing on total intensity. In later updates, SPTpol polarization data and new observations from the SPT-3G instrument at 90, 150, and 220 GHz will be included.

Hood, J.C., II [Chicago U., KICP; Chicago U., Astr↗

Cosmogenic activation of silicon

In the production of 3 H, 7 Be, and 22 Na by interactions of cosmic-ray particles with silicon can produce radioactive backgrounds in detectors used to search for rare events. Through controlled irradiation of silicon CCDs and wafers with a neutron beam that mimics the cosmic-ray neutron spectrum, followed by direct counting, we determined that the production rate from cosmic-ray neutrons at sea level is (112 ± 24) atoms/( kg day ) for 3 H, (8.1 ± 1.9) atoms/( kg day ) for 7 Be, and (43.0 ± 7.2) atoms/( kg day ) for 22 Na . Complementing these results with the current best estimates of activation cross sections for cosmic-ray particles other than neutrons, we obtain a total sea-level cosmic-ray production rate of (124 ± 25) atoms/(kg day) for 3 H, (9.4 ± 2.0) atoms/( kg day ) for 7 Be, and (49.6 ± 7.4) atoms/( kg day ) for 22 Na. These measurements will help constrain background estimates and determine the maximum time that silicon-based detectors can remain unshielded during detector fabrication before cosmogenic backgrounds impact the sensitivity of next-generation rare-event searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Machine Learning-Based Extreme Data Reduction for Prompt Supernova Pointing at DUNE

One of the goals of the Deep Underground Neutrino Experiment (DUNE) is to use the massive underground liquid argon time projection chamber (LArTPC) detectors at its far site for multimessenger astronomy (MMA), in the detection of neutrinos from core-collapse supernovae (SNe). Its current baseline trigger strategy detects activity in the detector that is consistent with supernova (SN) neutrinos and saves the raw data for further offline analysis but provides no prompt pointing information crucial for optical follow-ups by other observatories. This approach is based on the assumption that prompt pointing determination using raw data is computationally prohibitive. In this article, we demonstrate a proof-of-concept based on applying extreme data reduction on the buffered SN data in the DUNE data acquisition (DAQ) system’s front-end computers using a machine learning (ML) workflow. This reduces the data by ~5 orders of magnitude, allowing a full track reconstruction to be carried out quickly on a single server. The total time to perform the ML-based data reduction and the full track reconstruction is less than the time to transfer the SN data back to Fermilab or a high-performance computing (HPC) center. This shows that prompt processing of raw SN data is possible and, in fact, trivial once the data have been reduced to reject radiological backgrounds, paving the way to a high-quality SN pointing trigger that is based on fully reconstructed data instead of trigger primitives (TPs).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Angular scattering of protons through ultrathin graphene foils: Application for time-of-flight instrumentation

Space plasma instruments often rely on ultrathin carbon foils for incident ion detection, time-of-flight (TOF) mass spectrometry, and ionization of energetic neutral atoms. Angular scattering and energy loss of ions or neutral atoms in the foil can degrade instrument performance, including sensitivity and mass resolution; thus, there is an ongoing effort to manufacture thinner foils. Using new 3-layer graphene foils manufactured at the Los Alamos National Laboratory, we demonstrate that these are the thinnest foils reported to date and discuss future testing required for application in space instrumentation. We characterize the angular scattering distribution for 3–30 keV protons through the foils, which is used as a proxy for the foil thickness. We show that these foils are ~2.5–4.5 times thinner than the state-of-the-art carbon foils and ~1.6 times thinner than other graphene foils described in the literature. We find that the inverse relationship between angular scattering and energy no longer holds, reaffirming that this may indicate a new domain of beam–foil interactions for ultrathin (few-layer) graphene foils.

47 OTHER INSTRUMENTATION↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Global polarization of hyperons and spin alignment of vector mesons in quark matters

Relativistic heavy ion collider (RHIC) as a dedicated nuclear facility has made a few major discoveries in physics. This year marks the 30th year STAR Collaboration formation and the 23th year of STAR detector operation and data collection at RHIC. In the last two decades, STAR has collected many datasets, exhibiting scientific versatility and flexibility of the RHIC facility. The total dataset in the first year is less than 1 million good events, and currently there are about 1 billion events per dataset. The Global Hyperon Polarization was proposed in 2004. This immediately prompted the STAR Collaboration to search for this phenomenon from the early datasets. The null results were presented at Quark Matter Conference in Shanghai in 2006 and subsequently published. Although there were peripheral and continuous efforts in the following decade, no positive result has been observed experimentally. This situation changed in the following decade with the upgrade of high data rate and time-of-flight (TOF) detector and the progress of the Beam Energy Scan Phase I (BES-I). The experimental discoveries of the global polarization of hyperons in 2017 and the spin alignment of vector mesons in 2023 at RHIC-STAR confirm the theory which was established nearly twenty years ago. The theory and these measurements open the way to studying the properties of the hot and dense nuclear matter created in high-energy heavy ion collisions from a new degree of freedom, spin. We briefly review these discoveries from the proposals of theory to the experimental measurements, and summarize the related measurements at the existing facilities and the theoretical explanations to the original proposal. The basic understanding and the original proposal are still valid and fundamental, that is, the angular momentum of system can transform into a spin effect observable in experiment. However, it appears that in each case a new model is needed to explain the new experimental observation. We need a more basic theory to help us unify all these spin related phenomena. Over the past five years, STAR has successfully installed 3 new detectors and we have begun to see the physical analysis results from datasets with those new functions. What makes the STAR detector viable after 20 years of operation is its continuous evolution through successful upgrades, with new scientific programs added year by year. The next big thing is to forward upgrade a tracking system (3 layers of silicon strips and 4 layers of sTGC chambers) and a calorimetry system (electromagnetic and hadronic calorimeters). In addition to studying the spin structure of protons by using the polarized proton beams at RHIC, the upgrades also provide a unique ability to investigate the origin of Λ Global Polarization as a function of rapidity and rapidity (de-)correlations in Au+Au collisions.

Physics↗

Neutron Tagging From Neutrino Interactions in DUNE-ND 2x2 Prototype

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims to measure whether CP is violated in the leptonic sector (if violated, how much) and unambiguously determine the neutrino mass ordering. DUNE consists of near and far detectors that rely on liquid argon time projection chamber (LArTPC) technology to observe neutrino interactions. The near detector (ND) will be placed in Fermilab, near the neutrino source, while the far detector (FD) will be deployed in Sanford Lab, 1.5 km deep underground, which is 1300 km away from the source. LArTPCs provide excellent particle identification and calorimetry; however, detecting neutrons is challenging, as they do not leave direct ionization signals in LArTPCs. Neutrons can carry away up to 25% of the neutrino energy, introducing a significant uncertainty in DUNE measurements. The DUNE near detector (ND) features a novel modular LArTPC with pixelated charge readout, which enhances event recons truction. The modular design enables precise correlation between ionization signals and light signals in a high-rate environment, improving the identification of delayed energy depositions from neutrons in neutrino interactions. We introduce a neutron tagging technique using the 2x2 Demonstrator, a small-scale prototype of the DUNE ND LArTPC. The analysis utilizes Monte Carlo simulations and deep-learning techniques to identify neutron-induced energy depositions and reconstruct low-energy activity.

Kufatty, Georgette [Florida State U.]↗

Converting existing optical detectors into fast x-ray detectors

Here, the very short burn time and small size of burning plasmas created at advanced laser-fusion facilities will require high-spatial-resolution imaging diagnostics with fast time resolution. These instruments will need to function in an environment of extremely large neutron fluxes that will cause conventional diagnostics to fail because of radiation damage and induced background levels. One solution to this challenge is to perform an ultrafast conversion of the x-ray signals into the optical regime before the neutrons are able to reach the detector and then to relay image the signal out of the chamber and into a shielded bunker, protected from the effects of these neutrons. With this goal in mind, the OMEGA laser was used to demonstrate high-temporal-resolution x-ray imaging by using an x-ray snout to image an imploding backlighter capsule onto a semiconductor. The semiconductor was simultaneously probed with the existing velocity interferometry system for any surface reflector (VISAR) diagnostic, which uses an optical streak camera and provided a one-dimensional image of the phase in the semiconductor as a function of time. The phase induced in the semiconductor was linearly proportional to the x-ray emission from the backlighter capsule. This approach would then allow a sacrificial semiconductor to be attached at the end of an optical train with the VISAR and optical streak camera placed in a shielded bunker to operate in a high neutron environment and obtain time-dependent one-dimensional x-ray images or time-dependent x-ray spectra from a burning plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Search for New Physics through a Long-Lived Di-Muon Resonance in the NuMI Beam with the ICARUS Detector

Many of the unexplained phenomena in particle physics and cosmology today, such as the microphysical nature of dark matter, the strong CP problem, and the origin of the neutrino masses, can be resolved by the existence of a light (~GeV), weakly-coupled hidden sector of new physics. Such hidden sectors often predict the existence of “long-lived” particles (LLPs) that travel a far distance from production before decaying into Standard Model particles. Neutrino oscillation experiments, which combine intense particle beams with precise imaging detectors, are well equipped to probe LLP models with new sensitivity. This thesis details a search for a long-lived particle decaying to two muons with the ICARUS liquid argon time projection chamber (LArTPC) neutrino detector in the Short-Baseline Neutrino program at Fermilab. The calibration of the ICARUS time projection chamber (TPC) which enables the search is also presented. Notably, the calibration measures an angular dependence in electron-ion recombination in argon, a novel effect in the detector physics of LArTPCs. The search is performed using data taken with the Neutrinos at the Main Injector (NuMI) beam, with an exposure of 2.41e20 protons on target. No significant excess over background is observed, and we set world-leading limits on two new physics models that predict this process: the Higgs portal scalar and a heavy axion model. We also present the sensitivity in a model-independent way applicable to any new physics model predicting the process K → π + S(→μμ), for a long-lived particle S.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Active Neutron and Gamma-Ray Instrumentation for In Situ Planetary Science Applications

We describe the development of an instrument capable of detailed in situ bulk geochemical analysis of the surface of planets, moons, asteroids, and comets. This instrument technology uses a pulsed neutron generator to excite the solid materials of a planet and measures the resulting neutron and gamma-ray emission with its detector system. These time-resolved neutron and gamma-ray data provide detailed information about the bulk elemental composition, chemical context, and density distribution of the soil within 50 cm of the surface. While active neutron scattering and neutron-induced gamma-ray techniques have been used extensively for terrestrial nuclear well logging applications, our goal is to apply these techniques to surface instruments for use on any solid solar system body. As described, experiments at NASA Goddard Space Flight Center use a prototype neutron-induced gamma-ray instrument and the resulting data presented show the promise of this technique for becoming a versatile, robust, workhorse technology for planetary science, and exploration of any of the solid bodies in the solar system. The detection of neutrons at the surface also provides useful information about the material. This paper focuses on the data provided by the gamma-ray detector.

Parsons, A.↗

Synchronized Electronic Shutter System and Method for Thermal Nondestructive Evaluation

The invention is a synchronized electronic shutter system (SESS) and method for same side and through transmission thermal analysis and inspection of a material for finding defects, corrosion, disbond defects, integrity of a weld and determination of paint thickness. The system comprises an infrared detector that acquires background images of the sample. A shutter then covers the detector and lamps rapidly heat the sample above ambient temperature. Shutters cover all lamps at the same time the shutter over the infrared detector is opened. The infrared detector acquires a series of temperature images over time radiated from the sample a s the sample cools down. After collecting a series of temperature images taken by the SESS, a processed image is developed using one of the group comprising time derivative calculation, temperature normalization data reduction routine, thermal diffusivity curve fitting and averaging the series of temperature images.

Joseph N Zalameda↗

Initial Calibration of Large Timing Arrays for the LHC

In preparation for HL-LHC operation a number of new detector systems are being constructed with timing precision on physics objects of <50 picoseconds. These time stamps will reduce the level of pileup induced backgrounds in this LHC phase where the number of interactions per crossing will reach of order 100-200. In the case of CMS, three new systems have initially to be corrected for the usual amplitude walk resulting from the effect of variations in signal size on leading edge timing. In these systems the resulting timing spread (ie walk) ranges from one to four nanoseconds. In the following note we advocate approaching this initial calibration for walk as a calculable correction given early calibration during commissioning -- rather than depending on special collider data to perform the calibration. We derive a simple analytic expression for the walk correction and confirm its effectiveness with lab data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗