Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Hard X-ray and gamma-ray imaging spectroscopy for the next solar maximum

The objectives and principles are described of a single spectroscopic imaging package that can provide effective imaging in the hard X- and gamma-ray ranges. Called the High-Energy Solar Physics (HESP) mission instrument for solar investigation, the device is based on rotating modulation collimators with germanium semiconductor spectrometers. The instrument is planned to incorporate thick modulation plates, and the range of coverage is discussed. The optics permit the coverage of high-contrast hard X-ray images from small- and medium-sized flares with large signal-to-noise ratios. The detectors allow angular resolution of less than 1 arcsec, time resolution of less than 1 arcsec, and spectral resolution of about 1 keV. The HESP package is considered an effective and important instrument for investigating the high-energy solar events of the near-term future efficiently.

Hudson, H. S.↗

Coherent summation of spatially distorted laser Doppler signals by using a two-dimensional heterodyne detector array

Phase-sensitive coherent summation of individual heterodyne detector array signals was demonstrated for the enhanced detection of spatially distorted laser Doppler returns. With the use of a 2 x 2 heterodyne detector array, the phase and amplitude of a time-varying speckle pattern was detected, and the signal-to-noise ratio of the Doppler shift estimate was shown to be improved by a factor of 2, depending on the extent of spatial coherence loss. These results are shown to agree with a first-order analysis and indicate the advantage of coherent summation for both short-range laser Doppler velocimetry and long-range atmospheric coherent lidar.

Chan, Kin P.↗

Solar-diffuser panel and ratioing radiometer approach to satellite sensor on-board calibration

The use of a solar-diffuser panel is a desirable approach to the on-board absolute radiometric calibration of satellite multispectral sensors used for earth observation in the solar reflective spectral range. It provides a full aperture, full field, end-to-end calibration near the top of the sensor's dynamic range and across its entire spectral response range. A serious drawback is that the panel's reflectance, and the response of any simple detector used to monitor its reflectance may change with time. This paper briefly reviews some preflight and on-board methods for absolute calibration and introduces the ratioing-radiometer concept in which the radiance of the panel is ratioed with respect to the solar irradiance at the time the multispectral sensor is viewing the panel in its calibration mode.

Slater, Philip N.↗

Calibration of the COBE FIRAS instrument

The Far-Infrared Absolute Spectrophotometer (FIRAS) instrument on the Cosmic Background Explorer (COBE) satellite was designed to accurately measure the spectrum of the cosmic microwave background radiation (CMBR) in the frequency range 1-95/cm with an angular resolution of 7 deg. We describe the calibration of this instrument, including the method of obtaining calibration data, reduction of data, the instrument model, fitting the model to the calibration data, and application of the resulting model solution to sky observations. The instrument model fits well for calibration data that resemble sky condition. The method of propagating detector noise through the calibration process to yield a covariance matrix of the calibrated sky data is described. The final uncertainties are variable both in frequency and position, but for a typical calibrated sky 2.6 deg square pixel and 0.7/cm spectral element the random detector noise limit is of order of a few times 10(exp -7) ergs/sq cm/s/sr cm for 2-20/cm, and the difference between the sky and the best-fit cosmic blackbody can be measured with a gain uncertainty of less than 3%.

Fixsen, D. J.↗

System and Method for Measuring the Transfer Function of a Guided Wave Device

A method/system are provided for measuring the NxN scalar transfer function elements for an N-port guided wave device. Optical energy of a selected wavelength is generated at a source and directed along N reference optical paths having N reference path lengths. Each reference optical path terminates in one of N detectors such that N reference signals are produced at the N detectors. The reference signals are indicative of amplitude, phase and frequency of the optical energy carried along the N reference optical paths. The optical energy from the source is also directed to the N-ports of the guided wave device and then on to each of the N detectors such that N measurement optical paths are defined between the source and each of the N detectors. A portion of the optical energy is modified in terms of at least one of the amplitude and phase to produce N modified signals at each of the N detectors. At each of the N detectors, each of the N modified signals is combined with a corresponding one of the N reference signals to produce corresponding N combined signals at each of the N detectors. A total of N(sup 2) measurement signals are generated by the N detectors. Each of the N(sup 2) measurement signals is sampled at a wave number increment (Delta)k so that N(sup 2) sampled signals are produced. The NxN transfer function elements are generated using the N(sup 2) sampled signals. Reference and measurement path length constraints are defined such that the N combined signals at each of the N detectors are spatially separated from one another in the time domain.

Mark E Froggatt↗

Chandra Radiation Environment Modeling

CRMFLX (Chandra Radiation Model of ion FluX) is a radiation environment risk mitigation tool for use as a decision aid in planning the operations times for Chandra's Advanced CCD Imaging Spectrometer (ACIS) detector. The accurate prediction of the proton flux environment with energies of 100 - 200 keV is needed in order to protect the ACIS detector against proton degradation. Unfortunately, protons of this energy are abundant in the region of space Chandra must operate, and on-board particle detectors do not measure proton flux levels of the required energy range. This presentation will describe the plasma environment data analysis and modeling basis of the CRMFLX engineering environment model developed to predict the proton flux in the solar wind, magnetosheath, and magnetosphere phenomenological regions of geospace. The recently released CRMFLX Version 2 implementation includes an algorithm that propagates flux from an observation location to other regions of the magnetosphere based on convective ExB and VB-curvature particle drift motions. This technique has the advantage of more completely filling out the database and makes maximum use of limited data obtained during high Kp periods or in areas of the magnetosphere with poor satellite flux measurement coverage.

Minow, Joseph I.↗

GOME Total Ozone and Calibration Error Derived Usign Version 8 TOMS Algorithm

The Global Ozone Monitoring Experiment (GOME) is a hyper-spectral satellite instrument measuring the ultraviolet backscatter at relatively high spectral resolution. GOME radiances have been slit averaged to emulate measurements of the Total Ozone Mapping Spectrometer (TOMS) made at discrete wavelengths and processed using the new TOMS Version 8 Ozone Algorithm. Compared to Differential Optical Absorption Spectroscopy (DOAS) techniques based on local structure in the Huggins Bands, the TOMS uses differential absorption between a pair of wavelengths including the local stiucture as well as the background continuum. This makes the TOMS Algorithm more sensitive to ozone, but it also makes the algorithm more sensitive to instrument calibration errors. While calibration adjustments are not needed for the fitting techniques like the DOAS employed in GOME algorithms, some adjustment is necessary when applying the TOMS Algorithm to GOME. Using spectral discrimination at near ultraviolet wavelength channels unabsorbed by ozone, the GOME wavelength dependent calibration drift is estimated and then checked using pair justification. In addition, the day one calibration offset is estimated based on the residuals of the Version 8 TOMS Algorithm. The estimated drift in the 2b detector of GOME is small through the first four years and then increases rapidly to +5% in normalized radiance at 331 nm relative to 385 nm by mid 2000. The lb detector appears to be quite well behaved throughout this time period.

Gleason, J.↗

The Chandra X-Ray Observatory Radiation Environmental Model Update

CRMFLX (Chandra Radiation Model of ion FLUX) is a radiation environment risk mitigation tool for use as a decision aid in planning the operation times for Chandra's Advanced CCD Imaging Spectrometer (ACIS) detector. The accurate prediction of the proton flux environment with energies of 100 - 200 keV is needed in order to protect the ACIS detector against proton degradation. Unfortunately, protons of this energy are abundant in the region of space where Chandra must operate. In addition, on-board particle detectors do not measure proton flux levels of the required energy range. CRMFLX is an engineering environment model developed to predict the proton flux in the solar wind, magnetosheath, and magnetosphere phenomenological regions of geospace. This paper describes the upgrades to the ion flux databases for the magnetosphere, magnetosheath, and solar wind regions. These data files were created by using Geotail and Polar spacecraft flux measurements only when the Advanced Composition Explorer (ACE) spacecraft's 0.14 MeV particle flux was below a threshold value. This new database allows for CRMFLX output to be correlated with both the geomagnetic activity level, as represented by the Kp index, as well as with solar proton events. Also, reported in this paper are results of analysis leading to a change in Chandra operations that successfully mitigates the false trigger rate for autonomous radiation events caused by relativistic electron flux contamination of proton channels.

Blackwell, William C.↗

Method and apparatus for multiple-projection, dual-energy x-ray absorptiometry scanning

Methods and apparatuses for advanced, multiple-projection, dual-energy X-ray absorptiometry scanning systems include combinations of a conical collimator; a high-resolution two-dimensional detector; a portable, power-capped, variable-exposure-time power supply; an exposure-time control element; calibration monitoring; a three-dimensional anti-scatter-grid; and a gantry-gantry base assembly that permits up to seven projection angles for overlapping beams. Such systems are capable of high precision bone structure measurements that can support three dimensional bone modeling and derivations of bone strength, risk of injury, and efficacy of countermeasures among other properties.

Charles, Jr., Harry K.↗

Exploiting the Photoelectric effect for X-ray Polarimetry using Time Projection Chamber

The promise of photoelectric X-ray polarimetry has now been realized in laboratory demonstrations and may soon be used for astrophysical observations. Photoelectric polarimetry in gas filled proportional counters achieves high sensitivity through a combination of broad band width and good modulation. The band can be tuned by careful choice of gas composition and pressure. The measurements rely on imaging the tracks of photoelectrons. The initial direction of each track carries information about the electric field of the X-ray photon, and an ensemble of such measurements thus measures the net polarization of the source. A novel readout geometry using time projection chambers (TPC) allows deep (i.e. high efficiency) detectors, albeit without the ability to image the sky. Polarimeters which exploit the TPC geometry can be optimized for use behind telescopes, to study faint persistent sources, or as wide field of view instruments, designed to study bright transient events such as gamma-ray bursts or solar flares. We present the conceptual design of both types of TPC polarimeter. Recent laboratory results demonstrate that these polarimeters can achieve substantial gains in the polarization sensitivity achievable in experiments of modest size.

Jahoda, Keith↗

50 Years of Spaceflight with Fourier Transform Spectrometers (FTS) Built at NASA GSFC

Over the past 50 years, NASA Goddard Space Flight Center (GSFC) has been developing, building, testing and flying a series of Fourier Transform Spectrometers (FTS). This began with the IRIS instruments on the Earth-orbiting Nimbus satellites and progressed to more sophisticated designs optimized for interplanetary spacecraft sent to Mars and later to the outer solar system. Adaptions have been made over time, including progressively higher spectral resolution, sensitivity, numbers of detectors and complexity. Instrument operating temperatures have decreased to enable remote sensing of the cold giant planet systems. In this paper we describe the historical evolution of this instrument line, comparing and contrasting different aspects such as optical design and materials, detector types and data handling. We conclude by looking towards the future. At present the CIRS-Lite prototype is being tested at NASA GSFC for potential use on a future mission to the ice giants, Uranus and Neptune. Surpassing the previous performance of the Voyager IRIS instruments remains challenging, and new technologies that could enable these measurements are discussed.

Nixon, Conor A.↗

Prism Assembly for Roman Space Telescope Wide Field Instrument Slit-less Spectroscopy

The Roman Space Telescope (RST) is a three mirror anastigmat design with a 2.4 m primary mirror. RST will be based in L2 orbit, from where it will provide science information on exoplanets and dark energy using the Coronagraph Instrument (CGI) and Wide Field Instrument (WFI). The WFI features a 300 megapixel near-infrared detector array which provides a field of view 100 times larger than that of Hubble Space Telescope. The Prism Assembly is a small add-on instrument to the Roman Space Telescope’s Wide Field Instrument (WFI), installed in a slot in WFI’s element wheel. The Prism assembly has a passband from 0.75 µm to 1.8 µm, enabling a survey of redshifts in the range 0.2 to 1.7 µm. It provides low resolution slit-less spectroscopy with a spectral resolution R > 70 for all wavelengths, and R < 170 for λ > 0.8 µm across the full field. The Prism Assembly has the potential to provide more supernova spectra than ground-based spectroscopy during the mission lifetime. Being a late add-on to the RST mission, the Prism Assembly has had restrictions on size, weight and geometry, and a challenging schedule, which has dictated much of the implementation. Despite these challenges, the Prism Assembly is a pocket-sized high-performance spectrographic element, implemented as a refractive, all-spherical optical design using only two elements, one S-TIH-1 glass and one CaF2. This presentation will give an overview of the Prism Assembly, from design and implementation, through alignment, test and calibration. (100 words): The Roman Space Telescope is a three mirror anastigmat design with a 2.4 m primary mirror, which will provide science information on dark energy and exoplanets. The Prism Assembly is a small add-on instrument to the telescope’s Wide Field Instrument, enabling low resolution slit-less spectroscopy with a spectral resolution 70 < R < 170 across the full field from λ= 0.75 µm to 1.8 µm. The Prism Assembly is a refractive, all-spherical optical design using a glass and a CaF2 element. This presentation will give an overview of the Prism Assembly, from design and implementation, through alignment, test and calibration.

Space Instrumentation↗

JWST Noise Floor. II. Systematic Error Sources in JWST NIRCam Time Series

The James Webb Space Telescope (JWST) holds great promise for characterizing atmospheres of transiting exoplanets, potentially providing insights into Earth-sized planets within the habitable zones of M-dwarf host stars if photon-limited performance can be achieved. Here, we discuss the systematic error sources that are expected to be present in grism time-series observations with the NIRCam instrument. We find that pointing jitter and high-gain antenna moves in addition to the detectors' subpixel crosshatch patterns will produce relatively small variations (less than 6 parts per million, ppm). The time-dependent aperture losses due to thermal instabilities in the optics can also be kept to below 2 ppm. To achieve these low noise values, it is important to employ a sufficiently large (more than 1farcs1) extraction aperture. Persistence due to charge-trapping will have a minor (less than 3 ppm) effect on the time series 20 minutes into an exposure and is expected to play a much smaller role than it does for the Hubble Space Telescope WFC3 detectors. We expect detector temperature fluctuations to contribute less than 3 ppm. In total, our estimated noise floor from known systematic error sources is only 9 ppm per visit. We urge caution, however, because unknown systematic error sources could be present in flight and will only be measurable on astrophysical sources such as quiescent stars. We find that reciprocity failure may introduce a perennial instrument offset at the 40 ppm level, so corrections may be needed when a multi-instrument multi-observatory spectrum is stitched together over wide wavelength ranges.

Everett Schlawin↗

Solid-state Image Sensor with Focal-plane Digital Photon-counting Pixel Array

A solid-state focal-plane imaging system comprises an NxN array of high gain. low-noise unit cells. each unit cell being connected to a different one of photovoltaic detector diodes, one for each unit cell, interspersed in the array for ultra low level image detection and a plurality of digital counters coupled to the outputs of the unit cell by a multiplexer(either a separate counter for each unit cell or a row of N of counters time shared with N rows of digital counters). Each unit cell includes two self-biasing cascode amplifiers in cascade for a high charge-to-voltage conversion gain (greater than 1mV/e(-)) and an electronic switch to reset input capacitance to a reference potential in order to be able to discriminate detection of an incident photon by the photoelectron (e(-))generated in the detector diode at the input of the first cascode amplifier in order to count incident photons individually in a digital counter connected to the output of the second cascade amplifier. Reseting the input capacitance and initiating self-biasing of the amplifiers occurs every clock cycle of an integratng period to enable ultralow light level image detection by the may of photovoltaic detector diodes under such ultralow light level conditions that the photon flux will statistically provide only a single photon at a time incident on anyone detector diode during any clock cycle.

Fossum, Eric R.↗

Infrared astronomical imaging using a microcomputer data system

A small, portable data-acquisition and display system with a unique coprocessor was designed and built to collect data from infrared array detectors for astronomical and laboratory use. The system consists of a microcomputer board, two 12-bit analog-to-digital data-acquisition boards, a color-graphics driver board, and two coprocessor boards. The coprocessors are arithmetic logic units designed to achieve the high computation rates necessary for real-time infrared background cancellation. The system can collect data from infrared detectors of 1 to 256 pixel elements with a computation rate of 768 kHz. The software for the system was designed to collect data in the system's background, while performing other tasks in the system's foreground. The data for the detector arrays is stored in block fashion to facilitate variable image size.

Stafford, P. S.↗

Survey of candidate gamma-ray sources at TeV energies using a high-resolution Cerenkov imaging system - 1988-1991

The steady TeV gamma-ray emission from the Crab Nebula has been used to optimize the sensitivity of the Whipple Observatory atmospheric Cerenkov imaging telescope. Using this method, which is of order 20 times more sensitive than the standard method using a simple non-imaging detector, it is possible to detect the Crab Nebula at a significance level in excess of 6 standard deviations (6 sigma) in under 1 hr on source (with a corresponding time observing a background comparison region); a source one-tenth the strength of the Crab Nebula can be detected at the 4 sigma level after 40 hr on the source (and 40 hr on a background region). A variety of sources have been monitored using this technique over the period 1988-1991, but none were detected apart from the Crab Nebula. Upper limits are presented which in many instances are a factor of 10 below the flux of the Crab Nebula. These upper limits assume steady emission from the source and cannot rule out sporadic gamma-ray emission with short duty cycles.

Reynolds, P. T.↗

Quiet time energy spectra of heavy nuclei from 20 to 400 keV/amu

Glass track detectors were exposed to cosmic rays on the moon from December 11 to 13, 1972, during a period of relatively quiet sun activity as inferred from satellite proton counters. From 80 to 400 keV/amu, the differential flux of heavy cosmic ray nuclei decreases roughly as E to the -2nd power; this result together with the greater flux from the solar than the antisolar direction identify these nuclei as solar in origin.

Woods, R. T.↗

Impacts of Cross-Platform Vicarious Calibration on the Deep Blue Aerosol Retrievals for Moderate Resolution Imaging Spectroradiometer Aboard Terra

The retrieval of aerosol properties from spaceborne sensors requires highly accurate and precise radiometric measurements, thus placing stringent requirements on sensor calibration and characterization. For the Terra/Moderate Resolution Imaging Spedroradiometer (MODIS), the characteristics of the detectors of certain bands, particularly band 8 [(B8); 412 nm], have changed significantly over time, leading to increased calibration uncertainty. In this paper, we explore a possibility of utilizing a cross-calibration method developed for characterizing the Terral MODIS detectors in the ocean bands by the National Aeronautics and Space Administration Ocean Biology Processing Group to improve aerosol retrieval over bright land surfaces. We found that the Terra/MODIS B8 reflectance corrected using the cross calibration method resulted in significant improvements for the retrieved aerosol optical thickness when compared with that from the Multi-angle Imaging Spectroradiometer, Aqua/MODIS, and the Aerosol Robotic Network. The method reported in this paper is implemented for the operational processing of the Terra/MODIS Deep Blue aerosol products.

Jeong, Myeong-Jae↗