Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

12.6 keV Kr K-alpha X-ray Source For High Energy Density Physics Experiments

A high contrast 12.6 keV Kr K{alpha} source has been demonstrated on the petawatt-class Titan laser facility. The contrast ratio (K{alpha} to continuum) is 65, with a competitive ultra short pulse laser to x-ray conversion efficiency of 10{sup -5}. Filtered shadowgraphy indicates that the Kr K{alpha} and K{beta} x-rays are emitted from a roughly 1 x 2 mm emission volume, making this source suitable for area backlighting and scattering. Spectral calculations indicate a typical bulk electron temperature of 50-70 eV (i.e. mean ionization state 13-16), based on the observed ratio of K{alpha} to K{beta}. Kr gas jets provide a debris-free high energy K{alpha} source for time-resolved diagnosis of dense matter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transformation Kinetics of Phosphorus and Nitrogen in Iron-Rich Sewage Sludges during Hydrothermal Treatment and Recovery of Nutrients from Process Water

Hydrothermal treatment (HT) is an emerging technique for sustainable sewage sludge management and resource recovery. Many sludges are rich in iron (Fe) due to the common addition of Fe salts in water resource recovery facilities. To develop guidance for reaction conditions targeting nutrient recovery, this study systematically investigated the influence of HT temperature, treatment time, and sludge source on the dynamic speciation evolution of phosphorus (P) and nitrogen (N) during HT of Fe-rich sewage sludge. Complementary chemical extraction and X-ray spectroscopy analyses were conducted to characterize the treatment products. For the sludge mixture (a blend of primary and waste activated sludges), P speciation did not change significantly within 4.5 h at 125 °C HT, while soluble and labile P was converted into insoluble P over time at 175 and 225 °C HT. Strengite (FePO 4 · 2 H 2 O) preferentially formed in the hydrochars with increasing treatment temperature and/or time, whereas 125 °C HT within 1.5 h favored the formation of vivianite (Fe 3 (PO 4 ) 2 ·8H 2 O). Organic P was completely decomposed into orthophosphate when the HT temperature reached up to 175 °C. Pyrrole-N was enriched in the hydrochars. Similar reaction pathways were observed during HT of anaerobically digested sludge, though some minor differences in Fe-associated P and organic P were observed. Meanwhile, HT of the two sludges released orthophosphate and ammonia into the process waters at 175 and 225 °C, which can be recovered by a sequential process involving struvite (MgNH 4 PO 4 ·6H 2 O) precipitation and air stripping. This study provides new insights into the transformation of P and N during HT of Fe-rich sludges as well as a modular design for maximum P and N recovery from the treatment products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pulsed, Photonuclear-induced, Neutron Measurements of Nuclear Materials with Composite Shielding

Active measurements were performed using a 10-MeV electron accelerator with inspection objects containing various nuclear and nonnuclear materials available at the Idaho National Laboratory’s Zero Power Physics Reactor (ZPPR) facility. The inspection objects were assembled from ZPPR reactor plate materials to evaluate the measurement technologies for the characterization of plutonium, depleted uranium or highly enriched uranium shielded by both nuclear and non-nuclear materials. A series of pulsed photonuclear, time-correlated measurements were performed with unshielded calibration materials and then compared with the more complex composite shield configurations. The measurements used multiple 3He detectors that are designed to detect fission neutrons between pulses of an electron linear accelerator. The accelerator produced 10-MeV bremsstrahlung X-rays at a repetition rate of 125 Hz (8 ms between pulses) with a 4-us pulse width. All inspected objects were positioned on beam centerline and 100 cm from the X-ray source. The time-correlated data was collected in parallel using both a Los Alamos National Laboratory-designed list-mode acquisition system and a commercial multichannel scaler analyzer. A combination of different measurement configurations and data analysis methods enabled the identification of each object. This paper describes the experimental configuration, the ZPPR inspection objects used, and the various measurement and analysis results for each inspected object.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PSR J1907+0602: A RADIO-FAINT GAMMA-RAY PULSAR POWERING A BRIGHT TeV PULSAR WIND NEBULA

We present multiwavelength studies of the 106.6 ms gamma-ray pulsar PSR J1907+06 near the TeV source MGRO J1908+06. Timing observations with Fermi result in a precise position determination for the pulsar of R.A. = 19{sup h}07{sup m}54.{sup s}7(2), decl. = +06{sup 0}02'16(2)'' placing the pulsar firmly within the TeV source extent, suggesting the TeV source is the pulsar wind nebula of PSR J1907+0602. Pulsed gamma-ray emission is clearly visible at energies from 100 MeV to above 10 GeV. The phase-averaged power-law index in the energy range E > 0.1 GeV is GAMMA = 1.76 +- 0.05 with an exponential cutoff energy E{sub c} = 3.6 +- 0.5 GeV. We present the energy-dependent gamma-ray pulsed light curve as well as limits on off-pulse emission associated with the TeV source. We also report the detection of very faint (flux density of {approx_equal} 3.4 {mu}Jy) radio pulsations with the Arecibo telescope at 1.5 GHz having a dispersion measure DM = 82.1 +- 1.1 cm{sup -3} pc. This indicates a distance of 3.2 +- 0.6 kpc and a pseudo-luminosity of L{sub 1400} {approx_equal} = 0.035 mJy kpc{sup 2}. A Chandra ACIS observation revealed an absorbed, possibly extended, compact ({approx}<4'') X-ray source with significant nonthermal emission at R.A. = 19{sup h}07{sup m}54.{sup s}76, decl. = +06{sup 0}02'14.''6 with a flux of 2.3{sup +0.6}{sub -1.4} x 10{sup -14} erg cm{sup -2} s{sup -1}. From archival ASCA observations, we place upper limits on any arcminute scale 2-10 keV X-ray emission of {approx}1 x 10{sup -13} erg cm{sup -2} s{sup -1}. The implied distance to the pulsar is compatible with that of the supernova remnant G40.5 - 0.5, located on the far side of the TeV nebula from PSR J1907+0602, and the S74 molecular cloud on the nearer side which we discuss as potential birth sites.

79 ASTRONOMY AND ASTROPHYSICS↗

Spherical time-encoded radiation imaging simulations

Radiation source localization is important for nuclear nonproliferation and can be obtained using time-encoded imaging systems with unsegmented detectors. A scintillation crystal can be used with a moving coded-aperture mask to vary the detected count rate produced from radiation sources in the far field. The modulation of observed counts over time can be used to reconstruct an image with the known coded-aperture mask pattern. Current time-encoded imaging systems incorporate cylindrical coded-aperture masks and have limits to their fully coded imaging field-of-view. This work focuses on expanding the field-of-view to 4π by using a novel spherical coded-aperture mask. A regular icosahedron is used to approximate a spherical mask. This icosahedron consists of 20 equilateral triangles; the faces of which are each subdivided into four equilateral triangle-shaped voxels which are then projected onto a spherical surface, creating an 80-voxel coded-aperture mask. Furthermore, these polygonal voxels can be made from high-Z materials for gamma-ray modulation and/or low-Z materials for neutron modulation. In this work, we present Monte Carlo N-Particle (MCNP) simulations and simple models programmed in Mathematica to explore image reconstruction capabilities of this 80-voxel coded-aperture mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broad M-band multi-keV x-ray emission from plasmas created by short laser pulses

The investigation of the broad M-band x-ray emission from high-Z plasmas created by a laser, with a 30 fs to 3 ps pulse duration and achieving 10{sup 15-17} W/cm{sup 2} on target, is reported. Experimental emission spectra are measured in the energy range from 1.50 to 1.75 keV and discussed as potential backlighting x-ray sources for time-resolved x-ray absorption spectroscopy studies. They are compared with theoretical nonlocal thermodynamic equilibrium calculations of x-ray emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generalized Reference Fields and Source Interpolation for the Difference Formulation of Radiation Transport

In the difference formulation for the transport of thermally emitted photons, the photon intensity is defined relative to a reference field, the black body at the local material temperature. This choice of reference field combines the separate emission and absorption terms that nearly cancel, removing the dominant cause of noise in the Monte Carlo solution of thick systems, but introduces time and space derivative source terms that can not be determined until the end of the time step. The space derivative source term can also lead to noise induced crashes under certain conditions where the real physical photon intensity differs strongly from a black body at the local material temperature. In this paper, we consider a difference formulation relative to the material temperature at the beginning of the time step, or in cases where an alternative temperature better describes the radiation field, that temperature. The result is a method where iterative solution of the material energy equation is efficient and noise induced crashes are avoided. We couple our generalized reference field scheme with an ad hoc interpolation of the space derivative source, resulting in an algorithm that produces the correct flux between zones as the physical system approaches the thick limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical solution of the Stratonovich- and Ito–Euler equations: Application to the stochastic piston problem

We consider a piston with a velocity perturbed by Brownian motion moving into a straight tube filled with a perfect gas at rest. The shock generated ahead of the piston can be located by solving the one-dimensional Euler equations driven by white noise using the Stratonovich or Ito formulations. We approximate the Brownian motion with its spectral truncation and subsequently apply stochastic collocation using either sparse grid or the quasi-Monte Carlo (QMC) method. In particular, we first transform the Euler equations with an unsteady stochastic boundary into stochastic Euler equations over a fixed domain with a time-dependent stochastic source term. We then solve the transformed equations by splitting them up into two parts, i.e., a ‘deterministic part’ and a ‘stochastic part’. Numerical results verify the Stratonovich–Euler and Ito–Euler models against stochastic perturbation results, and demonstrate the efficiency of sparse grid and QMC for small and large random piston motions, respectively. The variance of shock location of the piston grows cubically in the case of white noise in contrast to colored noise reported in [1], where the variance of shock location grows quadratically with time for short times and linearly for longer times.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved Bayesian Infrasonic Source Localization for regional infrasound

The Bayesian Infrasonic Source Localization (BISL) methodology is examined and simplified providing a generalized method of estimating the source location and time for an infrasonic event and the mathematical framework is used therein. The likelihood function describing an infrasonic detection used in BISL has been redefined to include the von Mises distribution developed in directional statistics and propagation-based, physically derived celerity-range and azimuth deviation models. Frameworks for constructing propagation-based celerity-range and azimuth deviation statistics are presented to demonstrate how stochastic propagation modelling methods can be used to improve the precision and accuracy of the posterior probability density function describing the source localization. Infrasonic signals recorded at a number of arrays in the western United States produced by rocket motor detonations at the Utah Test and Training Range are used to demonstrate the application of the new mathematical framework and to quantify the improvement obtained by using the stochastic propagation modelling methods. Moreover, using propagation-based priors, the spatial and temporal confidence bounds of the source decreased by more than 40 per cent in all cases and by as much as 80 per cent in one case. Further, the accuracy of the estimates remained high, keeping the ground truth within the 99 per cent confidence bounds for all cases.

58 GEOSCIENCES↗

High-Resolution Neutron Cross-Section Measurements at the Oak Ridge Electron Linear Accelerator

Over the last three decades, the Oak Ridge Electron Linear Accelerator (ORELA) has produced many neutron-induced cross-section data. ORELA is the only high-power white neutron source with excellent time resolution still operating in the United States and is ideally suited for experiments to measure neutron fission, total, (n,), and capture cross sections in the energy range from 1 eV to as high as several MeV. Recent measurements have included neutron capture measurements on 39,41K, 35,37Cl, F, Mn, 58,60Ni, 53Cr, natural Cr, 48Ti, natural Ti, and 95Mo and total cross-section measurements on natural Cl, natural K, 95Mo, Mn, 53Cr, natural Cr, 48Ti, natural Ti, and 64Zn(n,). Many of these measurements were carried out to support the U.S. Nuclear Criticality Safety Program. Concerns have been raised about many of the older nuclear data evaluations important for criticality safety. For example, the time-of-flight resolution and accuracy of some of the existing data are too poor for new evaluations and thus applications. Several of these data are also important input parameters for the ongoing nuclear astrophysics program, which investigates the s-process nucleosynthesis in asymptotic giant branch stars. Here the Maxwellian-averaged neutron capture cross sections at kT = 8 and 30 keV are of importance. This paper provides an overview of the high-resolution cross-section measurement facility ORELA and describes the current measurement activities.

43 PARTICLE ACCELERATORS↗

Neutron Cross Section Measurements at ORELA for Improved Nuclear Data and Their Application

Many older neutron cross-section evaluations from libraries such as ENDF/B-VI or JENDL-3.2 exhibit deficiencies or do not cover energy ranges that are important for criticality safety applications. These deficiencies may occur in the resolved and unresolved-resonance regions. Consequently, these evaluated data may not be adequate for nuclear criticality calculations where effects such as self-shielding, multiple scattering, or Doppler broadening are important. To support the Nuclear Criticality Predictability Program, neutron cross-section measurements have been initiated at the Oak Ridge Electron Linear Accelerator (ORELA). ORELA is the only high-power white neutron source with excellent time resolution still operating in the United States. It is ideally suited to measure fission, neutron total, and capture cross sections in the energy range from 1 eV to {approx}600 keV, which is important for many nuclear criticality safety applications.

43 PARTICLE ACCELERATORS↗

The effect of temperature, storage time and collection method on biomethane potential of source separated household food waste

Highlights: • Experiments to mimic storage of OFMSW performed in laboratory scale at 6 and 22 °C. • A recipe representative for OFMSW from households in Sweden was designed. • Clear signs of degradation for OFMSW stored at 22 °C with respect to time. • Higher loss of VS and H{sub 2}O for OFMSW in paper bags compared to plastic bags at 22 °C. - Abstract: The aim of this study was to mimic real conditions for storage and transport and to evaluate how much of the biomethane potential is lost before the organic fraction of municipal solid waste (OFMSW) from households in Sweden reaches the biogas plant. The laboratory biomethane potential (BMP) experiments was carried out with respect to the storage time, collection method (paper or plastic bag) and storage temperature (22 °C and 6 °C) in order to evaluate the effect of these factors on the biomethane potential. A recipe representative for OFMSW from households in Sweden was designed with the help of literature and modification of recipes from technical reports and scientific literature. Laboratory experiments showed that the difference in the BMP of OFMSW stored in plastic- compared to paper bags were obvious at 22 °C with a lower biomethane potential for paper bags, but there was no difference at 6 °C. Provided that the loss of organic matter during pre-treatment is equivalent for both paper and plastic bags it is possible to get more biomethane from OFMSW collected in plastic bags during the warmest part of the year, since they have a more preservative effect on OFMSW than paper bags. This could be explained by the plastic bags being denser than paper and therefore maintain the volatile organic compounds inside the bag and promote a pre-hydrolysis of the material rather than aerobic degradation.

09 BIOMASS FUELS↗

A new tri-particle backlighter for high-energy-density plasmas (invited)

A new tri-particle mono-energetic backlighter based on laser-driven implosions of DT3He gas-filled capsules has been implemented at the OMEGA laser. This platform, an extension of the original D 3 He backlighter platform, generates 9.5 MeV deuterons from the T3He reaction in addition to 14.7 and 3.0 MeV protons from the deuterium and helium-3 reactants. The monoenergetic 14.7 and 3.0 MeV protons have been used with success at OMEGA and the NIF for both radiography and stopping-power studies. There are several advantages of having a third particle to diagnose plasma conditions: an extra time-of-flight-separated radiograph and an improved ability to discern between electric and magnetic fields. In cases where the 3.0 MeV protons cannot penetrate an experiment, the benefit of the additional 9.5 MeV deuterons is magnified. This capability is well-suited for NIF experiments, where large fields and plasma densities often preclude useful 3.0 MeV proton data. The advantages are demonstrated with radiographs of OMEGA plasmas with magnetic and electric fields. Tests using backlighter-scale 420 μm diameter thin glass capsules validate the platform’s extended backlighting capability. The performance characteristics of this backlighter, such as source size and timing, are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Realistic model of entanglement-enhanced sensing in optical fibers

Experimental limitations such as optical loss and noise have prevented entanglement-enhanced measurements from demonstrating a significant quantum advantage in sensitivity. Holland-Burnett entangled states can mitigate these limitations and still present a quantum advantage in sensitivity. Here we model a fiber-based Mach-Zehnder interferometer with internal loss, detector efficiency, and external phase noise and without pure entanglement. This model features a practical fiber source that transforms the two-mode squeezed vacuum (TMSV) into Holland-Burnett entangled states. We predict that a phase sensitivity 28% beyond the shot noise limit is feasible with current technology. Simultaneously, a TMSV source can provide about 25 times more photon flux than other entangled sources. This system will make fiber-based quantum-enhanced sensing accessible and practical for remote sensing and probing photosensitive materials.

Krueper, Gregory↗

Using GPU Programming for Inverse Spectroscopy

The Idaho National Laboratory (INL) has developed a detector that relies heavily on computationally expensive inverse spectroscopy algorithms to determine probabilistic three dimensional mappings of the source and its intensity. This inverse spectroscopy algorithm applies to material accountability due to the potential to determine where nuclear sources are present as a function of time and space. And yet because the novel algorithm can become prohibitively expensive on a standard desktop PC, the INL has incorporated new hardware from the commercial graphics community. General programming for graphics processing units (GPUs) is not a new concept. However, the application of GPUs to evidence theory-based inverse spectroscopy is both novel and particularly apropos. Improvements while using a (slightly upgraded) standard PC are approximately three orders of magnitude, making a ten hour computation in less than four seconds. This significantly changes the concept of prohibitively expensive calculations and makes application to materials accountability possible in near real time. Indeed, the sensor collection time is now expected to dominate the time required to determine the source and its intensity, instead of the inverse spectroscopy method.

97 MATHEMATICS AND COMPUTING↗

Alteration trends and geochemical source region characteristics preserved in the fluviolacustrine sedimentary record of Gale crater, Mars

The Mars Science Laboratory’s Chemistry and Camera (ChemCam) instrument suite on-board the Curiosity rover has analysed ~1200 sedimentary targets during the mission up to sol 1482. These targets have included sedimentary rock, diagenetic features (e.g., fracture-associated alteration halos, mineral veins, nodules, and erosion resistant raised ridges), active aeolian fines, soils and float. We have isolated ChemCam geochemical trends relating to diagenetic features and alteration products from those of the sedimentary rock in order to identify the compositional characteristics of Gale crater’s sediment source regions. The effects of grain size variation on sedimentary unit geochemistry have been taken into account by grouping and analysing geological units according to grain size. With obvious diagenetic features removed from the database, and predominately isochemical aqueous alteration inferred for the Mt Sharp Group samples, we propose that source region composition is a stronger source of geochemical change between the Bradbury and Mt Sharp Groups than open-system alteration. Additionally, a lack of correlation between the Chemical Index of Alteration (CIA) values and SiO 2 , MgO or FeO T indicates that the slight increase in chemical weathering of the Mt Sharp Group sediments was insufficient to overprint sediment source compositional signatures. This has led to the identification of five unique igneous endmember compositions which we hypothesise to have contributed to Gale crater’s stratigraphic record. These endmembers are: (1) a subalkaline basalt, compositionally similar to the tholeiitic Adirondack Class basalts of Gusev crater, and dominant within the finer grained units up to the base of Mt Sharp; (2) a trachybasalt, mostly identified within conglomerate units from the Darwin waypoint to the base of Mt Sharp; (3) a potassium-rich volcanic source, determined from strong potassium enrichment and a high abundance of sanidine that is most dominant in the fluvial sandstones and conglomerates of the Kimberley formation; (4) a highly evolved, silica-rich igneous source that correlates with the presence of tridymite, and is recorded in the lacustrine mudstone of Mt Sharp’s Marias Pass locality; and, (5) a fractionated, relatively SiO 2 -rich subalkaline basalt, seen to have influenced the composition of mudstone deposited in the lower part of the Mt Sharp Group. Endmembers (1), (2), (3), and (4) have previously been identified at specific waypoints along the rover’s traverse, but we show that their influence extends throughout Gale’s stratigraphic record. The occurrence of detected endmembers is also strongly correlated with stratigraphic position, which suggests changing sediment source regions with time. We conclude that Gale sediment provenances were much more varied than suggested by the largely homogenous, globally-distributed Martian basalt inferred from orbit, showing that complex magmatic assemblages exist within the ancient highland crust surrounding Gale.

58 GEOSCIENCES↗

Snake River Plain Geothermal Play Fairway Analysis Project MT Data

MT is measured in the field by using induction coils to measure the time-varying magnetic source for frequencies between 1000-0.001~Hz, and electric dipoles to measure the Earth's electrical response. Because the magnetic source field is polarized, orthogonal directions of the fields need to be measured to get a complete description of the fields. In all measurements collected for this project, induction coils and electric dipoles were aligned with geomagnetic north and east. MT data were collected at 22 stations with a ZEN 32-bit data logger developed by Zonge International, magnetic fields were measured with ANT-4 induction coils, and electric fields where measured with Ag-AgCl reference electrodes from Borin on 50~m dipoles. The data was collected on a repeating schedule of 10~min at 4096~samples/s and 7 hours and 50 minutes at 256 samples/s over a 20-24 hour period. To convert time series data into the frequency domain and get estimations of the impedance tensor, the processing code BIRRP was used (Chave & Thompson 2004). Simultaneous measurements were used as remote references to reduce noise and bias in the data. Chave, A. D., & Thomson, D. J. 2004. Bounded inuence magnetotelluric response function estimation. Geophys. J. Int., 157, 988-1006.

15 GEOTHERMAL ENERGY↗

THE 5 hr PULSE PERIOD AND BROADBAND SPECTRUM OF THE SYMBIOTIC X-RAY BINARY 3A 1954+319

We present an analysis of the highly variable accreting X-ray pulsar 3A 1954+319 using 2005-2009 monitoring data obtained with INTEGRAL and Swift. This considerably extends the pulse period history and covers flaring episodes in 2005 and 2008. In 2006 the source was identified as one of only a few known symbiotic X-ray binaries (SyXBs), i.e., systems composed of a neutron star accreting from the inhomogeneous medium around an M-giant star. The extremely long pulse period of {approx}5.3 hr is directly visible in the 2008 INTEGRAL-ISGRI outburst light curve. The pulse profile is double peaked and generally not significantly energy dependent although there is an indication of possible softening during the main pulse. During the outburst a strong spin-up of -1.8 Multiplication-Sign 10{sup -4} hr hr{sup -1} occurred. Between 2005 and 2008 a long-term spin-down trend of 2.1 Multiplication-Sign 10{sup -5} hr hr{sup -1} was observed for the first time for this source. The 3-80 keV pulse peak spectrum of 3A 1954+319 during the 2008 flare could be well described by a thermal Comptonization model. We interpret the results within the framework of a recently developed quasi-spherical accretion model for SyXBs.

79 ASTRONOMY AND ASTROPHYSICS↗