Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Remediating neutron damage in large area planar Ge-DSSD with amorphous germanium contacts through annealing and pulse-height correction

Large area, position sensitive planar germanium detectors offer new opportunities in -ray spectroscopy. For in-beam studies remediating neutron damage is important. This work studied a mechanically cooled circular planar 9 × 1 cm wafer with orthogonal 16 × 16 amorphous germanium strip electrodes. Before neutron irradiation the wafer was heated in-cryostat to above 373 K for more than 24 h in order to test the robustness of the contacts and the mechanical cooler. No deterioration in performance was observed. The detector was then exposed to controlled doses of 2.2 MeV neutrons, produced from the 7 Li(p,n) 7 Be reaction until substantial damage was observed. Averaged over the surface of the wafer, a flux of 1.9(1) x 10 9 n/cm 2 was delivered. The detector then survived thermal cycling and 350 K (~77°C) annealing for 70 h which substantially reduced hole trapping. pulse-height correction is investigated to further mitigate the neutron damage. Higher temperature annealing at 365 K was not successful.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Second Target Station Project: LANSCE WNR Target 2 (Blue Room) Experiment 2022

The Second Target Station (STS) at SNS will address emerging scientific challenges by providing a source of intense, cold neutrons to instruments optimized for this source, using rotating, tungsten target blocks. The STS target will receive 1.3 GeV proton beam pulses from the SNS accelerator at a repetition rate of 15 Hz. The facility life is planned for 40 years, and each target assembly life is expected to be approximately 10 years. An accurate strain prediction is then critical for fatigue life assessment of STS target blocks because they will be subject to approximately 108 beam pulses per lifetime. As an R&D activity, the LANSCE WNR Target 2 (blue room) facility was used to test the strain response of prototypical target blocks to the thermal shock of a proton pulse. The blue room was well suited for a pulsed proton beam impact test of subscale STS target blocks; the 800 MeV proton energy is approximately 60% of the 1.3 GeV proton energy expected from the SNS accelerator to the STS. Both the LANSCE Proton Storage Ring (PSR) and SNS are short-pulse proton beam sources with nominal pulse widths of 250 ns and 661 ns, respectively, so the energy deposition in the target occurs in < 1 microsecond pulse duration.

43 PARTICLE ACCELERATORS↗

The importance of phonon spectrum measurements for accurate prediction of thermal scattering laws [Slides]

Although approximate phonon spectra (e.g. Debye model) are sufficient to reproduce integral quantities (e.g. total INS cross section) in reasonable agreement with the measured data, more accurate phonon spectra are needed to achieve agreement with the differential data. SANS component is essential for reproducing the total scattering cross section; this is the case for nanodiamonds and other materials where SANS components are present (such as porous materials like nuclear graphite). A format proposal for SANS data in ENDF or GNDS is needed. Therefore, differential (e.g. phonon spectrum) and integral (e.g. total cross section) measurements are necessary in the process of creating an ENDF evaluation. We have successfully developed a method by which ENDF evaluations can be directly compared to the relevant experimentally measured quantities. INS experiments at SNS, ILL, ISIS, and, in the future, ESS, as well as total cross section measurements at the VESUVIO instrument at ISIS, are accessible through user programs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Robust analysis of space-, time-, and energy-resolved soft x-ray measurements of magnetically confined fusion plasmas (invited)

A novel compact multi-energy soft x-ray (ME-SXR) diagnostic based on the PILATUS3 100K x-ray detector has been developed in collaboration between the Princeton Plasma Physics Laboratory and the University of Wisconsin-Madison and tested on the Madison Symmetric Torus (MST) reversed-field pinch. This solid-state photon-counting detector consists of a two-dimensional array of ~100 000 pixels for which the lower photon absorption cutoff energy can be independently set, allowing it to be configured for a unique combination of simultaneous spatial, spectral, and temporal resolution of ~1 cm, 100 eV, and 500 Hz, respectively. The diagnostic is highly versatile and can be readily adapted to diverse plasma operating conditions and scientific needs without any required downtime. New results from improved-confinement and quasi-single helicity plasmas in the MST demonstrate how the detector can be applied to study multiple aspects of the evolution of magnetically confined fusion-grade plasmas. These include observing the evolution of thermal emissivity, characterizing the energy of mid-Z excitation lines, extracting the T e profile, and observing the evolution of non-thermal populations. A technique for integrating the ME-SXR diagnostic into an integrated data analysis framework based on Bayesian inference is also presented. As a result, this allows ME-SXR measurements to be combined with data for complementary diagnostics in order to simultaneously infer Te and nZ from all available information.

47 OTHER INSTRUMENTATION↗

Alignment tolerance analysis for divided-pulse nonlinear compression

We present an analytic model that describes the output pulse after Kerr-based spectral broadening with divided-pulse nonlinear compression that includes errors in unequal pulse division, birefringent plate retardance, and thermal drift. The model shows that alignment tolerances become impractically tight at high levels of nonlinearity and that the angle of incidence on the birefringent plates can be utilized as a compensator to loosen those tolerances. We present experimental verification of the model, which is expected to be a fast and flexible tool to design future divided-pulse nonlinear compression systems.

47 OTHER INSTRUMENTATION↗

Large-scale cascading of first-order FBG array in a highly multimode coreless fiber using femtosecond laser for distributed thermal sensing

This research focuses on the performance analysis and characterization of a fiber Bragg gratings (FBGs) array, consisting of 10 first-order FBGs inscribed by a femtosecond (FS) laser in a highly multimode coreless fiber. The study evaluates the FBG array's ability to function as a distributed thermal sensing (DTS) platform, with the coreless fiber chosen as the sensing element due to its immunity to dopant migration at high temperatures. The design of a large cascaded first-order FBG array effectively eliminates unwanted harmonic peaks across a wide spectrum range. In contrast, higher-order FBGs introduce limitations due to the overlapping of Bragg peaks with harmonics. The FBG array's performance is evaluated by measuring the reflection spectrum of each grating at different temperatures, showing a high temperature sensitivity of 15.05 pm/°C at a Bragg wavelength of 1606.3 nm, with a linear response in the temperature range of 24 - 1100 °C. The FBG array was designed for a spatial resolution of 5 mm. A mode scrambler in the sensing network is employed, which suppresses multimodal interference, characterizes FBG peak visibility, and stabilizes the interference spectrum. The stability of the FBG array is also assessed over 24 hrs at 1100 °C, and it is observed to be stable during thermal treatment. Heat treatment at 1100°C improves the signal to noise ratio of the FBG array, demonstrating the robustness and suitability of the proposed FBG array on highly multimode coreless fiber as a potential sensing platform for DTS applications in harsh environmental conditions, overcoming the issues of dopant migration presented by dopes silica optical fibers at high temperatures.

47 OTHER INSTRUMENTATION↗

Understanding spectral dependance of laser-induced damage precursors in dielectric materials (Full report_23-ERD-006)

The performance of high-energy laser systems is constrained by laser-induced damage in dielectric coatings, particularly those containing hafnium oxide (HfO 2 ). While thresholds at fundamental Nd harmonics are well studied, the spectral dependence of damage initiation—especially under dual-wavelength irradiation—remains poorly characterized. This project provides the first systematic investigation of wavelength-dependent laser damage in hafnia coatings, focusing on nanoscale precursors such as craze lines, nanobubbles, stoichiometric variations, nodules, and controlled crystallization. Coatings were fabricated via ion beam sputtering and electron-beam deposition and characterized using spectrophotometry, ellipsometry, AFM, GI-XRD, RBS, PCI absorption, and fs/ns laser damage testing. Results show that craze lines, benign under infrared light, strongly initiate damage under UV due to wavelength-selective field intensification. Substituting xenon for argon suppresses nanobubbles and improves UV thresholds by up to 32%. Oxygen modulation reveals that fully oxidized films maximize UV resistance, though at the cost of porosity and stress in multilayers. HfO 2 –SiO 2 composites resist crystallization and defects while achieving ppm-level absorption and elevated thresholds, whereas full crystallization of HfO 2 enhances LIDT by reducing defects and improving thermal transport. Collectively, these findings link photon energy, defect states, and bandgap collapse, providing a predictive framework for wavelength-dependent laser damage. The outcomes directly inform the design of durable, multi-wavelength coatings for facilities such as NIF, MEC, HAPLS, and DPAL, advancing the readiness of next-generation optics.

36 MATERIALS SCIENCE↗

The new Device for Indirect Capture Experiments on Radionuclides at LANSCE: Efforts on measuring the resonance(s) responsible for the extremely large 88 Zr (n,γ) cross section

The thermal neutron capture cross section of 88 Zr was recently reported to be the second largest in nature with the largest resonance integral measured. Presumably, these very large values are caused by a resonance or resonances very near thermal energy. Determining their energies and widths, and hence the shape of the cross section away from thermal energies,is useful for applications. The short half-life (83.4 days) and associated large background, renders direct measurements of the neutron capture cross section impossible using current techniques. However, it is possible to measure the total neutron cross section, and hence the resonance properties, using the newly commissioned Device for Indirect Capture Experiments on Radionuclides (DICER) at the Los Alamos Neutron Science Center (LANSCE). Transmission measurements are utilized as a surrogate method to perform capture measurements. The 88 Zr needed for a DICER measurement was produced at the Isotope Production Facility (IPF) and cleanly separated from the production target material. A description of the new instrument, efforts and preliminary results on 88 Zr will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tailoring coherent beam combined laser pulse trains for high peak and average power applications

Laser systems based on coherent beam combination (CBC) that rely on tiled pupil architecture intrinsically carry digital capabilities independently applicable to all three essential characteristics of a laser pulse: amplitude, phase and polarization. Those capabilities allow the far-field energy distribution to be flexibly tailored in real time. Operation in the femtosecond regime at high repetition rates gives access to a wide range of applications requiring both high peak and average powers. We address the task of independent peak versus average power adjustment needed for applications seeking to decouple nonlinear phenomena associated with GW peak power from the thermal load inherent to kW average power operation. The technical solutions proposed are presented in the framework of the Ecole Polytechnique XCAN CBC laser platform (61 independent channels) with an emphasis on thermal management measures implemented to ensure its nominal operation.

47 OTHER INSTRUMENTATION↗

Martensite decomposition during rapid heating of Ti-6Al-4V studied via in situ synchrotron X-ray diffraction

Martensite, α‘, commonly appears in Ti-6Al-4V upon rapid cooling from above the β-transus temperature. It is known that α‘ decomposes into α and β at high temperatures but well below the β-transus temperature. Here, we study the decomposition of martensitic Ti-6Al-4V under rapid laser heating, employing in situ synchrotron X-ray diffraction. A comparison is made with post-annealed Ti-6Al-4V under heating to elucidate changes without martensite decomposition. The fast acquisition of X-ray diffraction data at 250 Hz temporally resolves the decomposition process initiated by annihilating dislocations in α‘. The recovery process is accompanied by structural changes in martensite, followed by the phase transformation to β. Thermal profiles estimated from the lattice parameter data reveal the influence of heating rates and dislocation densities on the decomposition process. Throughout the analysis of the diffraction profiles with respect to estimated temperature, we propose a straightforward method for approximating the initiation temperature of martensite decomposition.

42 ENGINEERING↗

Proximal remote sensing: an essential tool for bridging the gap between high‐resolution ecosystem monitoring and global ecology

Summary A new proliferation of optical instruments that can be attached to towers over or within ecosystems, or ‘proximal’ remote sensing, enables a comprehensive characterization of terrestrial ecosystem structure, function, and fluxes of energy, water, and carbon. Proximal remote sensing can bridge the gap between individual plants, site‐level eddy‐covariance fluxes, and airborne and spaceborne remote sensing by providing continuous data at a high‐spatiotemporal resolution. Here, we review recent advances in proximal remote sensing for improving our mechanistic understanding of plant and ecosystem processes, model development, and validation of current and upcoming satellite missions. We provide current best practices for data availability and metadata for proximal remote sensing: spectral reflectance, solar‐induced fluorescence, thermal infrared radiation, microwave backscatter, and LiDAR. Our paper outlines the steps necessary for making these data streams more widespread, accessible, interoperable, and information‐rich, enabling us to address key ecological questions unanswerable from space‐based observations alone and, ultimately, to demonstrate the feasibility of these technologies to address critical questions in local and global ecology.

Plant Sciences↗

An Adaptive Reference Scheme to Extend the Functional Range of Optical Backscatter Reflectometry in Extreme Environments

Optical frequency domain reflectometry (OFDR) measurements are performed by recording the interference pattern of light backscattered by density fluctuations or Bragg gratings along the length of an optical fiber. Changes in local temperature or strain in the fiber cause shifts in the backscattered light spectrum, which can be calibrated to the applied temperature or strain. Comparing the backscattered optical spectra from each reflection site with a reference (unstrained) spectrum allows for quantification of local spectral shifts. While mature OFDR-based technologies can provide high-precision spatially distributed measurements over kilometer lengths, the post-processing approaches used to recover spectral shifts from raw optical intensity data can limit the use of OFDR in harsh environments. This paper presents a novel approach to post-processing OFDR data which extends the usability of optical fibers exposed to harsh environments. This approach is the first to use the spectral shift quality, calculated for two OFDR measurements, to identify an appropriate reference scan from which the spectral shift can be determined. Here, three experimental data sets are used to test the algorithm: (1) an optical fiber heated to >950°C, (2) an aluminum-embedded optical fiber under strain from differential thermal expansion, and (3) an optical fiber exposed to a total neutron flux of 2×10 13 n/cm 2 /s over 40 hours in a nuclear test reactor. Results show that using a metric of quality to select an appropriate reference measurement extends the functional range of OFDR strain and temperature sensors. Furthermore, this algorithm can be applied to existing OFDR data.

47 OTHER INSTRUMENTATION↗

Measurement of Plutonium Ratios for CRM 137A Recertification

This report documents the analytical methodologies used by the Chemical and Isotopics Mass Spectrometry (CIMS) Group at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) for plutonium isotopic ratio characterizations on purified ~1 mg units prepared by Lawrence Livermore National Laboratory (LLNL) from a mother solution created from an existing 250 mg unit of certified reference material (CRM) 137. The analytical processes described are designed to maintain traceability of the final certified attributes and to eliminate sources of systematic bias for the measurements described. The measurands for certification are the plutonium isotope ratios: 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu. The preparation and analytical process included the following activities: Preparation of reference materials to be used as calibrants to establish traceability to the SI unit of mass for the isotopic analyses and quality controls. For the plutonium isotopic analyses, CRM 128 (a CRM comprising equal atoms of 239 Pu and 242 Pu) was used as the primary calibrant; Each CRM 137A unit was reconstituted using dilute high-purity HNO3. From each, seven replicates were distributed for the isotopic characterizations by thermal ionization mass spectrometry (TIMS) using the total evaporation (TE) method for isotope ratio measurements and MC-ICP-MS using a dynamic peak hooping method for secondary isotope ratio measurements; Due to time delay in the analyses from the last purification of the original CRM 137 mother solution by LLNL, an aliquot of the three provided plutonium units was purified using Eichrom TEVA separation methods to remove americium in-growth and uranium impurities; Minimally corrected data were reported from each analysis using reporting templates provided by the New Brunswick Laboratory Program Office (NBL PO) for the specific methods used for isotopic measurements. In addition, a copy of the instrument exports, Excel templates for isotopic data corrections, and the uncertainty budgets completed with the GUM Workbench software package were submitted to NBL PO.

07 ISOTOPE AND RADIATION SOURCES↗

Compositional and phase dependence of elastic modulus of crystalline and amorphous Hf 1- x Zr x O 2 thin films

The elastic moduli of amorphous and crystalline atomic layer-deposited Hf 1-x Zr x O 2 (HZO, x = 0, 0.31, 0.46, 0.79, 1) films prepared with TaN electrodes on silicon substrates were investigated using picosecond acoustic measurements. The moduli of the amorphous films were observed to increase between 211 ± 6 GPa for pure HfO 2 and 302 ± 9 GPa for pure ZrO 2 . In the crystalline films, it was found that the moduli increased upon increasing the zirconium composition from 248 ± 6 GPa for monoclinic HfO 2 to 267 ± 9 GPa for tetragonal ZrO 2 . Positive deviations from this increase were observed for the Hf 0.69 Zr 0.31 O 2 and Hf 0.54 Zr 0.46 O 2 compositions, which were measured to have moduli of 264 ± 8 GPa and 274 ± 8 GPa, respectively. These two compositions contained the largest fractions of the ferroelectric orthorhombic phase, as assessed from polarization and diffraction data. The biaxial stress states of the crystalline films were characterized through sin 2 (ψ) x-ray diffraction analysis. The in-plane stresses were all found to be tensile and observed to increase with the increasing zirconium composition, between 2.54 ± 0.6 GPa for pure HfO 2 and 5.22 ± 0.5 GPa for pure ZrO 2 . The stresses are consistent with large thermal expansion mismatches between the HZO films and silicon substrates. Furthermore, these results demonstrate a device-scale means to quantify biaxial stress for investigation on its effect on the ferroelectric properties of hafnia-based materials.

36 MATERIALS SCIENCE↗

Automated, Unmanned Detection and Quantification of Fugitive Methane Emissions

Compressor stations used to move natural gas are one of the largest sources of fugitive methane emissions in the midstream sector, accounting for approximately 50% of all fugitive emissions (Zimmerle et al., 2015). This problem is most widespread at reciprocating compressors (Subramanian et al., 2015) where faulty seals are a key contributor to methane emissions (Johnson et al., 2015). As such, there is a significant need for a robust technology that could provide an early indication of an unexpected emission. Equally important, the technology needs to be able to account for biogenic versus anthropogenic sources of methane. One means of indirectly making this determination, is to leverage optical technologies that can autonomously pinpoint the source of such leaks. This presentation discusses recent work funded by the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL), focused on the development of an innovative remote sensing technology that can reliably and autonomously detect fugitive methane emissions in near real-time, using computer vision and deep learning. The technology called the Smart Methane Leak Detection (SLED/M) system was initially developed to monitor facilities such as compressor stations in a stationary, pan-tilt-zoom configuration. The system has recently been adapted to monitor facilities from an unmanned aerial system (UAS). The speed and maneuverability of UAS platforms are attractive to leak detection and repair program operators, but introduce several challenges. Many existing methane detection algorithms rely on mostly static backgrounds becoming unusable with motion. In addition, top-down views of fugitive methane emissions present differently in Optical Gas Imagers (OGI) compared to looking across the plume. Our work has focused on overcoming these challenges, enhancing the operators ability to detect methane emissions, and pinpoint their sources. Another recent adaptation to SLED/M is the ability to quantify methane emissions using passive sensors (OGI, thermal camera), environmental conditions, plume modeling, and deep learning. SLED/M advances the state-of-the-art for methane emission detection and quantification by focusing on three key critical criteria for effective methane emission mitigation: (1) autonomy (no need for a human to be in the loop), (2) high reliability (low false alarm rates), and (3) real-time performance. Results from this work will be presented.

03 NATURAL GAS↗

Sensitivity Analyses of Natural Convection in the AP1000 Passive Containment Cooling System Following LBLOCA Using CFD

The AP1000 power plant has implemented multiple layers of passive safety systems to enhance reactor safety and ensure system integrity during postulated scenarios, such as loss of coolant accident (LOCA) and main steam line break (MSLB). Among these, the passive containment cooling system (PCCS) is a safety-related system designed to prevent the containment from exceeding the design limits of both pressure and temperature following a postulated design basis accident, by transferring heat from the steel containment vessel to the atmosphere. During LOCA, natural air convection plays a vital role in removing heat from the steel containment vessel to the atmosphere. This is integrated with the condensate film from the Passive Containment Cooling Water Storage Tank (PCCWST). Air natural convection is also the only heat removal mechanism after the dry-out of the PCCWST and during the loss of shutdown decay heat removal (LOSDHR) event. Therefore, it is essential to investigate the thermal hydraulics behavior of the containment under transient conditions to ensure its safety and integrity. This paper presents a simplified CFD/ANSYS FLUENT model developed to analyze the impact of different parameters, such as air relative humidity, air temperature, and steel containment temperature, on the natural convection capability to remove the decay heat following LOCA. The model aims to examine the thermal behavior of the containment and provides a comprehensive understanding of the system's natural convection capability during postulated accidents. The results obtained from the model can be used to improve the safety and integrity of the containment system and provide valuable insights for future research in the field.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Acoustics Reveals Short–Term Air Temperature Fluctuations Near Mars' Surface

Acoustics is new on Mars: it allows the characterization of turbulence at smaller scales than previously possible within the lowest part of the Planetary Boundary Layer. Sound speed measurements, by the SuperCam instrument and its microphone onboard the NASA Perseverance rover, allow the retrieval of atmospheric temperatures at 0.77 m above the ground, at 3 Hz, with a ~10 ms response time that is 20–100 times shorter than for typical thermocouple sensors used on Mars. Here we report on the first measurements of the sound speed-derived temperature and its fluctuations near the surface. Data highlight large and rapid fluctuations up to ±7 K/s, whose amplitude over such a timescale has never been reported, nor predicted by atmospheric models. These fluctuations follow the daytime pattern of the turbulence and highlight occasional high amplitude events that are likely due to the conjunction of low thermal inertia and strong winds.

79 ASTRONOMY AND ASTROPHYSICS↗