Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Scaling Relationships Based on Scaled Tank Mixing and Transfer Test Results

This report documents the statistical analyses performed (by Pacific Northwest National Laboratory for Washington River Protection Solutions) on data from 26 tests conducted using two scaled tanks (43 and 120 inches) in the Small Scale Mixing Demonstration platform. The 26 tests varied several test parameters, including mixer-jet nozzle velocity, base simulant, supernatant viscosity, and capture velocity. For each test, samples were taken pre-transfer and during five batch transfers. The samples were analyzed for the concentrations (lbs/gal slurry) of four primary components in the base simulants (gibbsite, stainless steel, sand, and ZrO2). The statistical analyses including modeling the component concentrations as functions of test parameters using stepwise regression with two different model forms. The resulting models were used in an equivalent performance approach to calculate values of scaling exponents (for a simple geometric scaling relationship) as functions of the parameters in the component concentration models. The resulting models and scaling exponents are displayed in tables and graphically. The sensitivities of component concentrations and scaling exponents to the test parameters are presented graphically. These results will serve as inputs to subsequent work by other researchers to develop scaling relationships that are applicable to full-scale tanks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scaling Relationships Based on Scaled Tank Mixing and Transfer Test Results

This report documents the statistical analyses performed (by Pacific Northwest National Laboratory for Washington River Protection Solutions) on data from 26 tests conducted using two scaled tanks (43 and 120 inches) in the Small Scale Mixing Demonstration platform. The 26 tests varied several test parameters, including mixer-jet nozzle velocity, base simulant, supernatant viscosity, and capture velocity. For each test, samples were taken pre-transfer and during five batch transfers. The samples were analyzed for the concentrations (lbs/gal slurry) of four primary components in the base simulants (gibbsite, stainless steel, sand, and ZrO 2 ). The statistical analyses including modeling the component concentrations as functions of test parameters using stepwise regression with two different model forms. The resulting models were used in an equivalent performance approach to calculate values of scaling exponents (for a simple geometric scaling relationship) as functions of the parameters in the component concentration models. The resulting models and scaling exponents are displayed in tables and graphically. The sensitivities of component concentrations and scaling exponents to the test parameters are presented graphically. These results will serve as inputs to subsequent work by other researchers to develop scaling relationships that are applicable to full-scale tanks.

Equivalent Performance↗

DETERMINISTIC COMPONENTS IN THE LIGHT CURVE AMPLITUDE OF Y OPH

About two decades after the discovery of the amplitude decline of the light curve of the classical Cepheid Y Oph, its study is resumed using an increased amount of homogenized data and an extended time base. In our approach, the investigation of different time series concerning the light curve amplitude of Y Oph is not only the reason for the present study, but also a stimulus for developing a coherent methodology for studying long- and short-term variability phenomena in variable stars, taking into account the details of concrete observing conditions: amount of data, data sampling, time base, and individual errors of observational data. The statistical significance of this decreasing trend was estimated by assuming its linearity. We approached the decision-making process by formulating adequate null and alternative hypotheses, and testing the value of the regression line slope for different data sets via Monte Carlo simulations. A variability analysis, through various methods, of the original data and of the residuals obtained after removing the linear trend was performed. We also proposed a new statistical test, based on amplitude spectrum analysis and Monte Carlo simulations, intended to evaluate how detectible is a given (linear) trend in well-defined observing conditions: the trend detection probability. The main conclusion of our study on Y Oph is that, even if the false alarm probability is low enough to consider the decreasing trend to be statistically significant, the available data do not allow us to obtain a reasonably powerful test. We are able to confirm the light curve amplitude decline, and the order of magnitude of its slope with a better statistical substantiation. According to the obtained values of the trend detection probability, it seems that the trend we are dealing with is marked by a low detectibility. Our attempt to find signs of possible variability phenomena at shorter timescales ended by emphasizing the relative constancy of our data, within their precision limits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intermediate Ethanol Blends Catalyst Durability Program

In the summer of 2007, the U.S. Department of Energy (DOE) initiated a test program to evaluate the potential impacts of intermediate ethanol blends (also known as mid-level blends) on legacy vehicles and other engines. The purpose of the test program was to develop information important to assessing the viability of using intermediate blends as a contributor to meeting national goals for the use of renewable fuels. Through a wide range of experimental activities, DOE is evaluating the effects of E15 and E20 - gasoline blended with 15% and 20% ethanol - on tailpipe and evaporative emissions, catalyst and engine durability, vehicle driveability, engine operability, and vehicle and engine materials. This report provides the results of the catalyst durability study, a substantial part of the overall test program. Results from additional projects will be reported separately. The principal purpose of the catalyst durability study was to investigate the effects of adding up to 20% ethanol to gasoline on the durability of catalysts and other aspects of the emissions control systems of vehicles. Section 1 provides further information about the purpose and context of the study. Section 2 describes the experimental approach for the test program, including vehicle selection, aging and emissions test cycle, fuel selection, and data handling and analysis. Section 3 summarizes the effects of the ethanol blends on emissions and fuel economy of the test vehicles. Section 4 summarizes notable unscheduled maintenance and testing issues experienced during the program. The appendixes provide additional detail about the statistical models used in the analysis, detailed statistical analyses, and detailed vehicle specifications.

02 PETROLEUM↗

SU-D-201-04: Evaluation of Elekta Agility MLC Performance Using Statistical Process Control

Purpose: to evaluate the performance and stability of the Elekta Agility MLC model using an automated quality control (QC) test in combination with statistical process control tools. Methods: Leaf positions were collected daily for 11 Elekta units over 5–19 months using the automated QC test, which analyzes 23 MV images to determine the location of MLC leaves relative to the radiation isocenter. The leaf positions are measured at 5 nominal positions, and images are acquired at collimator 0° and 180° to capture all MLC leaves in the field-of-view. Leaf positioning accuracy was assessed using individual and moving range control charts. Control limits were recomputed following MLC recalibration (occurred 1–2 times for 4 units). Specification levels of ±0.5, ±1 and ±1.5mm were tested. The mean and range of duration between out-of-control and out-of-specification events were determined. Results: Leaf position varied little over time, as confirmed by very tight individual control limits (mean ±0.19mm, range 0.09–0.44). Mean leaf position error was −0.03mm (range −0.89–0.83). Due to sporadic out-of-control events, the mean in-control duration was 3.3 days (range 1–23). Data stayed within ±1mm specification for 205 days on average (range 3–372) and within ±1.5mm for the entire date range. Measurements stayed within ±0.5mm for 1 day on average (range 0–17); however, our MLC leaves were not calibrated to this level of accuracy. Conclusion: The Elekta Agility MLC model was found to perform with high stability, as evidenced by the tight control limits. The in-specification durations support the current recommendation of monthly MLC QC tests with a ±1mm tolerance. Future work is on-going to determine if Agility performance can be optimized further using high-frequency QC test results to drive recalibration frequency. Factors that can affect leaf positioning accuracy, including beam spot motion, leaf gain calibration, drifting leaves, and image artifacts, are under investigation.

60 APPLIED LIFE SCIENCES↗

Periodicity significance testing with null-signal templates: reassessment of PTF’s SMBH binary candidates

Periodograms are widely employed for identifying periodicity in time series data, yet they often struggle to accurately quantify the statistical significance of detected periodic signals when the data complexity precludes reliable simulations. We develop a data-driven approach to address this challenge by introducing a null-signal template (NST). The NST is created by carefully randomizing the period of each cycle in the periodogram template, rendering it non-periodic. It has the same frequentist properties as a periodic signal template, and we show with simulations that the distribution of false positives is the same as with the original periodic template, regardless of the underlying data. Thus, performing a periodicity search with the NST acts as an effective simulation of the null (no-signal) hypothesis, without having to simulate the noise properties of the data. We apply the NST method to the supermassive black hole binaries (SMBHB) search in the Palomar Transient Factory (PTF), where Charisi et al. had previously proposed 33 high signal-to-noise candidates utilizing simulations to quantify their significance. Our approach reveals that these simulations do not capture the complexity of the real data. There are no statistically significant periodic signal detections above the non-periodic background. To improve the search sensitivity, we introduce a Gaussian quadrature based algorithm for the Bayes Factor with correlated noise as a test statistic. We show with simulations that this improves sensitivity to true signals by more than an order of magnitude. However, the Bayes Factor approach also results in no statistically significant detections in the PTF data.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-187: Quantifying Normal Tissue Sparing with 4D Robust Optimization of Intensity Modulated Proton Therapy

Purpose: To report an approach to quantify the normal tissue sparing for 4D robustly-optimized versus PTV-optimized IMPT plans. Methods: We generated two sets of 90 DVHs from a patient’s 10-phase 4D CT set; one by conventional PTV-based optimization done in the Eclipse treatment planning system, and the other by an in-house robust optimization algorithm. The 90 DVHs were created for the following scenarios in each of the ten phases of the 4DCT: ± 5mm shift along x, y, z; ± 3.5% range uncertainty and a nominal scenario. A Matlab function written by Gay and Niemierko was modified to calculate EUD for each DVH for the following structures: esophagus, heart, ipsilateral lung and spinal cord. An F-test determined whether or not the variances of each structure’s DVHs were statistically different. Then a t-test determined if the average EUDs for each optimization algorithm were statistically significantly different. Results: T-test results showed each structure had a statistically significant difference in average EUD when comparing robust optimization versus PTV-based optimization. Under robust optimization all structures except the spinal cord received lower EUDs than PTV-based optimization. Using robust optimization the average EUDs decreased 1.45% for the esophagus, 1.54% for the heart and 5.45% for the ipsilateral lung. The average EUD to the spinal cord increased 24.86% but was still well below tolerance. Conclusion: This work has helped quantify a qualitative relationship noted earlier in our work: that robust optimization leads to plans with greater normal tissue sparing compared to PTV-based optimization. Except in the case of the spinal cord all structures received a lower EUD under robust optimization and these results are statistically significant. While the average EUD to the spinal cord increased to 25.06 Gy under robust optimization it is still well under the TD50 value of 66.5 Gy from Emami et al. Supported in part by the NCI U19 CA021239.

60 APPLIED LIFE SCIENCES↗

Using a Simple Binomial Model to Assess Improvement in Predictive Capability: Sequential Bayesian Inference, Hypothesis Testing, and Power Analysis

We present a Bayesian statistical methodology for identifying improvement in predictive simulations, including an analysis of the number of (presumably expensive) simulations that will need to be made in order to establish with a given level of confidence that an improvement has been observed. Our analysis assumes the ability to predict (or postdict) the same experiments with legacy and new simulation codes and uses a simple binomial model for the probability, {theta}, that, in an experiment chosen at random, the new code will provide a better prediction than the old. This model makes it possible to do statistical analysis with an absolute minimum of assumptions about the statistics of the quantities involved, at the price of discarding some potentially important information in the data. In particular, the analysis depends only on whether or not the new code predicts better than the old in any given experiment, and not on the magnitude of the improvement. We show how the posterior distribution for {theta} may be used, in a kind of Bayesian hypothesis testing, both to decide if an improvement has been observed and to quantify our confidence in that decision. We quantify the predictive probability that should be assigned, prior to taking any data, to the possibility of achieving a given level of confidence, as a function of sample size. We show how this predictive probability depends on the true value of {theta} and, in particular, how there will always be a region around {theta} = 1/2 where it is highly improbable that we will be able to identify an improvement in predictive capability, although the width of this region will shrink to zero as the sample size goes to infinity. We show how the posterior standard deviation may be used, as a kind of 'plan B metric' in the case that the analysis shows that {theta} is close to 1/2 and argue that such a plan B should generally be part of hypothesis testing. All the analysis presented in the paper is done with a general beta-function prior for {theta}, enabling sequential analysis in which a small number of new simulations may be done and the resulting posterior for {theta} used as a prior to inform the next stage of power analysis.

42 ENGINEERING↗

Validation of a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial HDR brachytherapy

Purpose: In current clinical practice, there is no integrated 3D ultrasound (3DUS) guidance system clinically available for breast brachytherapy. In this study, the authors present a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial high dose rate (HDR) brachytherapy treatment. Methods: For this work, a new computer controlled robotic 3DUS system was built to perform a hybrid motion scan, which is a combination of a 6 cm linear translation with a 30° rotation at both ends. The new 3DUS scanner was designed to fit on a modified Kuske assembly, keeping the current template grid configuration but modifying the frame to allow the mounting of the 3DUS system at several positions. A finer grid was also tested. A user interface was developed to perform image reconstruction, semiautomatic segmentation of the surgical bed as well as catheter reconstruction and tracking. A 3D string phantom was used to validate the geometric accuracy of the reconstruction. The volumetric accuracy of the system was validated with phantoms using magnetic resonance imaging (MRI) and computed tomography (CT) images. In order to accurately determine whether 3DUS can effectively replace CT for treatment planning, the authors have compared the 3DUS catheter reconstruction to the one obtained from CT images. In addition, in agarose-based phantoms, an end-to-end procedure was performed by executing six independent complete procedures with both 14 and 16 catheters, and for both standard and finer Kuske grids. Finally, in phantoms, five end-to-end procedures were performed with the final CT planning for the validation of 3DUS preplanning. Results: The 3DUS acquisition time is approximately 10 s. A paired Student t-test showed that there was no statistical significant difference between known and measured values of string separations in each direction. Both MRI and CT volume measurements were not statistically different from 3DUS volume (Student t-test: p > 0.05) and they were significantly correlated to 3DUS measurement (Pearson test: MRI p < 0.05 and CT p < 0.001). The mean angular separation distance between catheter trajectories segmented from 3DUS and CT images was 0.42° ± 0.24°, while the maximum and mean trajectory separations were 0.51 ± 0.19 and 0.37 ± 0.17 mm, respectively. Overall, the new finer grid has performed significantly better in terms of dosimetric indices. The planning target volume dosimetric indices were not found statistically different between 3DUS and CT planning (Student t-test, p > 0.05). Both the skin and the pectoral muscle dosimetric indices were within ABS guidelines. Conclusions: A novel robot-assisted 3DUS system was designed and validated. To their knowledge, this is the first system capable of performing real-time guidance and planning of breast multicatheter HDR brachytherapy treatments. Future investigation will test the feasibility of using the system in the clinic and for permanent breast brachytherapy.

60 APPLIED LIFE SCIENCES↗

Statistical Analysis and Geologic Evaluation of Laboratory-Derived Physical Property Data for Selected Nevada Test Site Core Samples of Non-Zeolitized Tuffs

A statistical analysis and geologic evaluation of recently acquired laboratory-derived physical property data are being performed to better understand and more precisely correlate physical properties with specific geologic parameters associated with non-zeolitized tuffs at the Nevada Test Site. Physical property data include wet and dry bulk density, grain density (i.e., specific gravity), total porosity, and effective porosity. Geologic parameters utilized include degree of welding, lithology, stratigraphy, geographic area, and matrix mineralogy (i.e., vitric versus devitrified). Initial results indicate a very good correlation between physical properties and geologic parameters such as degree of welding, lithology, and matrix mineralogy. However, physical properties appear to be independent of stratigraphy and geographic area, suggesting that the data are transferrable with regards to these two geologic parameters. Statistical analyses also indicate that the assumed grain density of 2.65 grams per cubic centimeter used to calculate porosity in some samples is too high. This results in corresponding calculated porosity values approximately 5 percent too high (e.g., 45 percent versus 40 percent), which can be significant in the lower porosity rocks. Similar analyses and evaluations of zeolitic tuffs and carbonate rock physical properties data are ongoing as well as comparisons to geophysical log values.

58 GEOSCIENCES↗

Test Vector Development for Verification and Validation of Heavy-Duty Autonomous Vehicle Operations

The current focus in the ongoing development of autonomous driving systems (ADS) for heavy duty vehicles is that of vehicle operational safety. To this end, developers and researchers alike are working towards a complete understanding of the operating environments and conditions that autonomous vehicles are subject to during their mission. This understanding is critical to the testing and validation phases of the development of autonomous vehicles and allows for the identification of both the nominal and edge case scenarios encountered by these systems. Previous work by the authors saw the development of a comprehensive scenario generation framework to identify an operating domain specification (ODS), or external and internal conditions an autonomous driving system can expect to encounter on its mission to form critical scenario groups for autonomous vehicle testing and validating using statistical patterns, clustering, and correlation. Continuing this prior work, this paper focuses on the generation of test cases based on the critical scenarios identified that can be used to prioritize either the most common nominal driving scenarios or the least common severe driving scenarios. These test cases can then be used validate, through simulation or real-world testing, the operating design domain (ODD) for a generalized driving mission and built upon to identify spatial and temporal impacts on the driving mission of an autonomous vehicle.

Siekmann, Adam↗

Contributions of Various Radiological Sources to Background in a Suburban Environment

This work is a brief overview and comparison of dose rates stemming from both indoor and outdoor natural background radiation and household objects within a suburban environment in North Carolina. Combined gamma and beta dose rates were taken from indoor objects that ranged from the potassium in fruit to the americium in smoke detectors. For outdoor measurements, various height and time data samples were collected to show fluctuations in dose rate due to temperature inversion and geometric attenuation. Although each sample tested proved to have a statistically significant increase over background using Students t-test, no sample proved to be more than a minor increase in natural radiation dose. Furthermore, the relative contributions from natural radioactivity such as potassium in foods and common household items are shown to be easily distinguished from background using standard handheld instrumentation when applied in a systematic, methodological manner.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fracture Stress Data for SiC Layers in the TRISO-Coated Fuel Particles

A crush testing method for hemispherical shell specimens was developed based on the result of finite element (FE) analysis on stress distribution, and was applied to the evaluation of fracture strength for the chemical vapor deposited (CVD) SiC layers of tri-isotropic (TRISO) fuel particles. This report presents descriptions on the testing and evaluation procedures, SiC fracture data, and Weibull statistics parameters. In the mechanical testing, hemispherical shell specimens of SiC layers removed from TRISO particles were diametrically loaded between a bottom base and a plunger with brass foil at its end. The fracture in the shells always initiates at the inner surface below the loading contact at the convex (outer) surface. Producing a highly uniform stress distribution under the loading contact area is necessary to accurately evaluate the fracture stress from the measured fracture load data by using an analytical solution. Finite element analysis confirms that a relatively soft metal (brass foil) inserted between the specimen’s convex surface and plunger tip produced a highly uniform stress distribution under the contact area. Some conventional crust test methods without defining effective volume or area cause difficulties in interpretation of fracture strength data because a strong size effect exists in the fracture test results from miniature specimens. In this study a major improvement was made by using a simple experimental method to obtain the effective area.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Chandrasekhar's relation and stellar rotation in the Kepler field

According to the statistical law of large numbers, the expected mean of identically distributed random variables of a sample tends toward the actual mean as the sample increases. Under this law, it is possible to test the Chandrasekhar's relation (CR), (V) = (π/4){sup –1}(Vsin i), using a large amount of Vsin i and V data from different samples of similar stars. In this context, we conducted a statistical test to check the consistency of the CR in the Kepler field. In order to achieve this, we use three large samples of V obtained from Kepler rotation periods and a homogeneous control sample of Vsin i to overcome the scarcity of Vsin i data for stars in the Kepler field. We used the bootstrap-resampling method to estimate the mean rotations ((V) and (Vsin i)) and their corresponding confidence intervals for the stars segregated by effective temperature. Then, we compared the estimated means to check the consistency of CR, and analyzed the influence of the uncertainties in radii measurements, and possible selection effects. We found that the CR with (sin i) = π/4 is consistent with the behavior of the (V) as a function of (Vsin i) for stars from the Kepler field as there is a very good agreement between such a relation and the data.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of Cerebellum Radiation Dosimetry on Cognitive Outcomes in Children With Infratentorial Ependymoma

Purpose: Cognitive decline is a recognized effect of radiation therapy (RT) in children treated for brain tumors. The importance of the cerebellum and its contribution to cognition have been recognized; however, the effect of RT on cerebellum-linked neurocognitive deficits has yet to be explored. Methods and Materials: Seventy-six children (39 males) at a median 3.3 years of age (range, 1-17 years old) were irradiated for infratentorial ependymoma from 1997 to 2008. The total prescribed dose was 54 to 59.4 Gy administered to the postoperative tumor bed with 5- or 10-mm clinical target volume margin. Age-appropriate cognitive and academic testing was performed prior to the start of RT and was then repeated at 6 months and annually throughout 5 years. The anterior and posterior cerebellum and other normal brain volumes were contoured on postcontrast, T1-weighted postoperative magnetic resonance images registered to treatment planning computed tomography images. Mean doses were calculated and used with time after RT and other clinical covariates to model their effect on neurocognitive test scores. Results: Considering only the statistically significant rates in longitudinal changes for test scores and models that included mean dose, there was a correlation between mean infratentorial dose and intelligence quotient (IQ; −0.190 patients/Gy/year; P=.001), math (−0.164 patients/Gy/year; P=.010), reading (−0.137 patients/Gy/year; P=.011), and spelling scores (−0.147 patients/Gy/year; P=.012), where Gy was measured as the difference between the mean dose received by an individual patient and the mean dose received by the patient group. There was a correlation between mean anterior cerebellum dose and IQ scores (−0.116 patients/Gy/year; P=.042) and mean posterior cerebellum dose and IQ (−0.150 patients/Gy/year; P=.002), math (−0.120 patients/Gy/year; P=.023), reading (−0.111 patients/Gy/year; P=.012), and spelling (−0.117 patients/Gy/year; P=.015) scores. Conclusions: Sparing portions of the cerebellum should be considered in RT planning for children with infratentorial ependymoma because of the potential impact of radiation dose on cognitive function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗