Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature dependence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Lower critical field measurements in YBa2Cu3O(6+x) single crystals

The temperature dependence of the lower critical field in YBa2Cu3O(6+x) single crystals was determined by magnetization measurements with the applied field parallel and perpendicular to the c-axis. Results are compared with data from the literature and fitted to Ginzberg-Landau equations by assuming a linear dependence of the parameter kappa on temperature. A value of 7 plus or minus 2 kOe was estimated for the thermodynamic critical field at T = O by comparison of calculated H (sub c2) values with experimental data from the literature.

Kaiser, D. L.↗

Analysis of the upper atmosphere CO2(nu-2) vibrational temperatures retrieved from ATMOS/Spacelab 3 observations

An analysis of the upper atmospheric (80-116 km) CO2(nu-2) vibrational temperatures retrieved from atmospheric trace molecule spectroscopy (ATMOS) experiment Spacelab 3 spectra by using a nonlocal thermodynamic equilibrium (non-LTE) radiative transfer model is presented. Thermal collisions with atmospheric atomic oxygen keep this vibrational state very close to LTE up to around 100 km. Above this height, the different deviations from LTE retrieved from ATMOS/Spacelab 3 spectra for the Northern and the Southern Hemispheres are explained in terms of this collisional process and in terms of the different kinetic temperature profiles measured at those locations. From these simultaneous observations of the kinetic and CO2(nu-2) vibrational temperatures, a deactivation rate of CO2(nu-2) by O(3P) has been derived which leads to a rate coefficient value between 3 and 6 x 10 exp -12 cu cm/s and favors an independent or negative temperature dependence rate constant for the atmospheric temperature range. Cooling rates induced by the CO2 15-micron fundamental band in the upper mesosphere and lower thermosphere were derived from the simultaneous kinetic temperature, CO2(nu-2) vibrational temperature, and CO2 concentration, as measured by ATMOS/Spacelab 3, and found to be a factor of between 5 and 10 times larger than those generally accepted until very recently.

Lopez-Puertas, M.↗

Volatile transport on Venus and implications for surface geochemistry and geology

The high vapor pressure of volatile metal halides and chalcogenides (e.g., of Cu, Zn, Sn, Pb, As, Sb, Bi) at typical Venus surface temperatures, coupled with the altitude-dependent temperature gradient of approximately 8.5 K/km, is calculated to transport volatile metal vapors to the highlands of Venus, where condensation and accumulation will occur. The predicted geochemistry of volatile metals on Venus is supported by observations of CuCl in volcanic gases at Kilauea and Nyiragongo, and large enrichments of these and other volatile elements in terrestrial volcanic aerosols. A one-dimensional finite difference vapor transport model shows the diffusive migration of a thickness of 0.01 to greater than 10 microns/yr of moderately to highly volatile phases (e.g., metal halides and chalcogenides) from the hot lowlands (740 K) to the cold highlands (660 K) on Venus. The diffusive transport of volatile phases on Venus may explain the observed low emissivity of the Venusian highlands, hazes at 6-km altitude observed by two Pioneer Venus entry probes, and the Pioneer Venus entry probe anomalies at 12.5 km.

Brackett, Robert A.↗

Water vapor absorption in the atmospheric window at 239 GHz

Absolute absorption rates of pure water vapor and mixtures of water vapor and nitrogen have been measured in the atmospheric window at 239 GHz. The dependence on pressure as well as temperature has been obtained. The experimental data are compared with several theoretical or empirical models, and satisfactory agreement is obtained with the models involving a continuum; in the case of pure water vapor, the continuum contribution based upon recent theoretical developments gives good results. The temperature dependence is stronger than that proposed in a commonly used atmospheric transmission model.

Bauer, A.↗

Investigation of Anomalous Behavior in Metallic-Based Materials Under Compressive Loading

An anomalous material response has been observed under the action of applied compressive loads in fibrous SiC/Ti (both Ti-6242 and Ti-15-3 alloys) and the monolithic nickel-base alloy IN-718 in the aged condition. The observed behavior is an increase, rather than a decrease, in the instantaneous Young's modulus with increasing load. This increase is small, but can be significant in yield surface determination tests, where an equivalent offset strain on the order of 10 micron(1 x 10(exp -6) m/m) is being used. Stiffening has been quantified by calculating offset strains from the linear elastic loading line. The offset strains associated with stiffening during compressive loading are positive and of the same order as the target offset strains in yield surface determination tests. At this time we do not have a reasonable explanation for this response nor can we identify a deformation mechanism that might cause it. On the other hand, we are not convinced that it is an artifact of the experimental procedure because a number of issues have been identified and seemingly ruled out. In fact, stiffening appears to be temperature dependent, since it decreases as the temperature increases.

Gil, Christopher M.↗

Thermal Model Performance for the James Webb Space Telescope OTIS Cryo-Vacuum Test

The James Webb Space Telescope (JWST), set to launch in mid-2020, is currently undergoing a series of system-level environmental tests to verify its workmanship and end-to-end functionality. As part of this series, the Optical Telescope Element and Integrated Science Instrument Module (OTIS) Cryo-Vacuum (CV) test, the most complex cryogenic test executed to date by NASA, has recently been completed at the Johnson Space Center's Chamber A facility. The OTIS CV test was intended as a comprehensive test of the integrated instrument and telescope systems to fully understand its optical, structural, and thermal performance within its intended flight environment. Due to its complexity, extensive pre-test planning was required to ensure payload safety and compliance with all limits and constraints. A system-level pre-test thermal model was constructed which fully captured the behavior of the payload, ground support equipment, and surrounding test chamber. This thermal model simulated both the transient cooldown to and warmup from a 20 K flight-like environment, as well as predicted the payload performance at cryo-stable conditions. The current work is an assessment of thermal model pre-test prediction performance against actual payload response during the OTIS CV test. Overall, the thermal model performed exceedingly well at predicting schedule and payload response. Looking in depth, this work examines both the benefits and shortcomings of assumptions made pre-test to simplify model execution when compared against test data. It explores in detail the role of temperature-dependent emissivities during transition to cryogenic temperatures, as well as the impact that model geometry simplifications have on tracking of critical hardware limits and constraints. This work concludes with a list of recommendations to improve the accuracy of thermal modeling for future large cryogenic tests. The insight gained from the OTIS CV test thermal modeling will benefit planning and execution for upcoming cryogenic missions.

Testing↗

Thermal Model Performance for the James Webb Space Telescope OTIS Cryo-Vacuum Test

The James Webb Space Telescope (JWST), set to launch in early 2019, is currently undergoing a series of system-level environmental tests to verify its workmanship and end-to-end functionality. As part of this series, the Optical Telescope Element and Integrated Science Instrument Module (OTIS) Cryo-Vacuum (CV) test, the most complex cryogenic test executed to date by NASA, has recently been completed at the Johnson Space Center's Chamber A facility. The OTIS CV test was intended as a comprehensive test of the integrated instrument and telescope systems to fully understand its optical, structural, and thermal performance within its intended flight environment. Due to its complexity, extensive pre-test planning was required to ensure payload safety and compliance with all limits and constraints. A system-level pre-test thermal model was constructed which fully captured the behavior of the payload, ground support equipment, and surrounding test chamber. This thermal model simulated both the transient cooldown to and warmup from a 20K flight-like environment, as well as predicted the payload performance at cryo-stable conditions. The current work is a preliminary assessment of thermal model performance against actual payload response during the OTIS CV test. It examines both the benefits and shortcomings of assumptions made pre-test to simplify model execution when compared against test data. It explores in detail the role of temperature-dependent emissivities during transition to cryogenic temperatures, as well as the impact that model geometry simplifications have on tracking of critical hardware limits and constraints. This work concludes with a list of recommendations to improve the accuracy of thermal modeling for future large cryogenic tests. It is hoped that the insight gained from the OTIS CV test thermal modeling will benefit planning and execution for upcoming cryogenic missions.

JWST↗

Thermal Model Performance for the James Webb Space Telescope OTIS Cryo-Vacuum Test

The James Webb Space Telescope (JWST), set to launch in early 2019, is currently undergoing a series of system-level environmental tests to verify its workmanship and end-to-end functionality. As part of this series, the Optical Telescope Element and Integrated Science Instrument Module (OTIS) Cryo-Vacuum (CV) test, the most complex cryogenic test executed to date by NASA, has recently been completed at the Johnson Space Center’s Chamber A facility. The OTIS CV test was intended as a comprehensive test of the integrated instrument and telescope systems to fully understand its optical, structural, and thermal performance within its intended flight environment. Due to its complexity, extensive pre-test planning was required to ensure payload safety and compliance with all limits and constraints. A system-level pre-test thermal model was constructed which fully captured the behavior of the payload, ground support equipment, and surrounding test chamber. This thermal model simulated both the transient cooldown to and warmup from a 20K flight-like environment, as well as predicted the payload performance at cryo-stable conditions. The current work is a preliminary assessment of thermal model performance against actual payload response during the OTIS CV test. Overall, the thermal model performed exceedingly well at predicting schedule and payload response. Looking in depth, this work examines both the benefits and shortcomings of assumptions made pre-test to simplify model execution when compared against test data. It explores in detail the role of temperature-dependent emissivities during transition to cryogenic temperatures, as well as the impact that model geometry simplifications have on tracking of critical hardware limits and constraints. This work concludes with a list of recommendations to improve the accuracy of thermal modeling for future large cryogenic tests. It is hoped that the insight gained from the OTIS CV test thermal modeling will benefit planning and execution for upcoming cryogenic missions.

Yang, Kan↗

Temperature and pressure dependence of dichloro-difluoromethane (CF2C12) absorption coefficients for CO2 waveguide laser radiation

Measurements were performed to determine the pressure and temperature dependence of CFM-12 absorption coefficients for CO2 waveguide laser radiation. The absorption coefficients of CFM-12 for CO2 waveguide laser radiation were found to have no spectral structure within small spectral bandwidths around the CO2 waveguide laser lines in the CO2 spectral band for pressures above 20 torr. All of the absorption coefficients for the CO2 laser lines studied are independent of pressure above 100 torr, except for the P(36) laser CO2 spectral band. The absorption coefficients associated with the P(42) line in the same band showed the greatest change with temperature, and it also has the largest value of all the lines studied.

Harward, C. N.↗

Partitioning of Ni/2+/ between basaltic and synthetic melts and olivines An experimental study

Olivine/liquid distribution coefficients for Ni in basaltic and simple synthetic melts are found in the 1400-1070 C temperature range. The results suggest that: (1) the Ni distribution coefficients and NiO activity coefficients are strongly temperature dependent, (2) the Ni distribution coefficients are functions of melt composition and structure at a constant temperature although the dependence is small for most basaltic magmas, (3) differences in melt composition do not significantly influence generally 'basaltic' melts, (4) the Ni distribution coefficients may be used as geothermometers to predict the olivine crystallization temperatures of basaltic magmas to within plus or minus 50 C, (5) the Ni distribution coefficients are greater than one at all natural magmatic temperatures, and (6) the Ni distribution coefficients do not significantly vary as functions of the Ni content of the melt to at least one mole percent.

Leeman, W. P.↗

Application of Satellite-Derived Land Surface Temperature to Minimum Temperature Forecasting

Satellite-derived land surface temperature (LST) is studied for the purpose of understanding regional skin temperature dependency and variability, and its relationship to corresponding, site-specific air temperature. Skin temperature is highly correlated with surface-air temperature although it differs depending on land surface characteristics, terrain, and atmospheric conditions on a diurnal and seasonal scale. The high temporal resolution of the Geostationary Operational Environmental Satellite (GOES) -12 sounder is used to compare the diurnal cycles of LST and surface-air temperature. The minimum for both temperatures occurs near sunrise and LST is found to agree closely with surface-air temperatures a period of hours before sunrise on clear sky nights. The Moderate Resolution Imaging Spectroradiometer (MODIS)-derived LST renders more horizontal temperature structure - with its high spatial resolution (1 km at nadir) compared to the GOES-12 sounder (10 km). Nighttime MODIS-derived LST is extrapolated to the time of minimum temperature for a number of case study days and these are grouped by season and atmospheric conditions. These composites show that the variation in LST mirror the variation in minimum surface-air temperature under similar conditions.

Jones, P. R.↗

The long-term performance degradation of a radioisotope thermoelectric generator using silicon germanium

The successful utilization of a radioisotope thermoelectric generator (RTG) as the power source for spaceflight missions requires that the performance of such an RTG be predictable throughout the mission. Several mechanisms occur within the generator which tend to degrade the performance as a function of operating time. The impact which these mechanisms have on the available output power of an RTG depends primarily on such factors as time, temperature and self-limiting effects. The relative magnitudes, rates and temperature dependency of these various degradation mechanisms have been investigated separately by coupon experiments as well as 4-couple and 18-couple module experiments. This paper discusses the different individual mechanisms and summarizes their combined influence on the performance of an RTG. Also presented as part of the RTG long-term performance characteristics is the sensitivity of the available RTG output power to variations of the individual degradation mechanisms thus identifying the areas of greatest concern for a successful long-term mission.

Stapfer, G.↗

Fresnel-Fizeau effect in a rotating optical fiber ring interferometer

Measurements of the Fresnel-Fizeau effect in a fiber ring interferometer gyroscope are reported. The presence of the dispersion term in the Fresnel drag coefficient was discernable. The temperature dependence of the coefficient bears on the temperature sensitivity of the optical fiber gyroscope. An alternate approach to measuring fiber dispersion is an added benefit, leading to determination of maximum pulse rate transmitted through single-mode fibers.

Vali, V.↗

Radiative dominated cooling of the flare corona and transition region

Models in which radiation dominates cooling flare loops are investigated. The radiative models are found to predict a differential emission measure (Q) proportional to T to the (l+1) power, where l measures the dependence of the radiative loss coefficient on temperature, lamda (T) approximately T to the (-l) power. It is concluded that the radiative models are incapable of explaining the observed temperature dependence of Q for flare coronal and transitional plasma. The models suggest that large mass motions (velocities of the order of the sound speed) may be required.

Antiochos, S. K.↗

Thermohydrodynamic analysis for laminar lubricating films

A Galerkin-type analysis to include thermal effects in laminar lubricating films was performed. The lubricant properties were assumed constant except for a temperature-dependent Newtonian viscosity. The cross-film temperature profile is established by collocation at the film boundaries and two interior Lobatto points. The interior temperatures are determined by requiring that the zeroth and first moment of the energy equation be satisfied across the film. The fluidity is forced to conform to a third--degree polynomial appropriate to the Lobatto-point temperatures. Preliminary indications are that the use of just two such sampling points enables satisfactory prediction of bearing performance even in the presence of substantial viscosity variation.

Elrod, H. G.↗

Raman spectroscopic investigations of Hg-Cd-Te melts

Raman scattering measurements are reported for a series of Hg sub1-xCd subxTe (with x less than or =0.2) materials from 295 K (room temperature) to 1126K (up to and above their liquidus temperatures), and for Hg sub1-xCd subxTe (x=0.3) at 285K. The samples were contained in high-temperature optically-flat fused silica cell. Variable temperature measurements were effected in a three-zone, high-temperature furnace equipped with optical windows, and monitored externally by three independently programmable temperature controllers. All studies were made in the backscattering geometry using the 5145 A line of an Ar+ ion laser, with incident power less than 250 mW, as the excitiation source. An intensity enhancement is observed for a mode in each of the compositions studied. The frequency of this mode varies with composition, 142/cm for HgTe, and 128/cm for both the Hg sub1-xCd subxTe (x=0.053 and 0.204) samples. In addition, a shift to lower frequency as a function of temperature is observed in all samples. This shift is most prominent for the x=0.053 sample. The temperature dependence of these modes as the liquidus temperatures are achieved and surpassed for these samples is presented as being associated with a structural transition in the Hg-rich compositions of the Hg sub1-xCd subxTe series. To our knowledge, this is the first reported study of Raman scattering by phonons in the melts of these materials.

Morrobel-Sosa, Anny↗