Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Low Cost Entry, Descent, and Landing (EDL) Instrumentation for Planetary Missions

Missions that involve traversing through a planetary atmosphere are unique opportunities that require elements of entry, descent, and landing (EDL). Many aspects of the EDL sequence are qualified using analysis and simulation due to the inability to conduct appropriate ground tests, however validating flight data are often lacking, especially for missions not involving Earth re-entry. NASA has made strategic decisions to collect EDL flight data in order to improve future mission designs. For example, MEDLI1 and EFT-1 gathered hypersonic pressure and in-depth temperature data in the thermal protection system (TPS). However, the ability to collect EDL flight data from the smaller competed missions, such as Discovery and New Frontiers, has been limited in part due to the Principal Investigator-managed cost-caps (PIMCC). The recent NASA decision to consider EDL instrumentation earlier in the mission design cycle led to the inclusion of a requirement in the Discovery 2014 Announcement of Opportunity which requires all missions that involve EDL to include an Engineering Science Investigation (ESI).2 The ESI would involve sensors for aerothermal environment and TPS; atmosphere, aerodynamics, and flight dynamics; atmospheric decelerator; and/or vehicle structure.3 The ESI activity would be funded outside of the PIMCC.

and Landing↗

Performance Investigation of a Full-Scale Hybrid Composite Bull Gear

Hybrid composite gears have been investigated as a weight saving technology for rotorcraft transmissions. These gears differ from conventional steel gears in that the structural material between the shaft interface and the gear rim is replaced with a lightweight carbon fiber composite. The work discussed here is an extension of previous coupon level hybrid gear tests to a full-scale bull gear. The NASA Glenn Research Center High-Speed Helical Gear Rig was modified for this program, allowing several hybrid gear web configurations to be tested while utilizing the same gear rim. Testing was performed on both a baseline (steel) web configuration and a hybrid (steel-composite) configuration. Vibration, orbit and temperature data were recorded and compared between configurations. Vibration levels did not differ greatly between the hybrid and steel configurations, nor did temperature differential between inlet and outlet. While orbit shape displayed differences between the hybrid and baseline configurations, the general overall amplitude was comparable. The hybrid configuration discussed here successfully ran at 3300 hp (2,460 kW), however, progressive growth of the orbit while running at this test condition discontinued the test. Further studies are planned to determine the cause of this behavior.

Gears↗

Performance Investigation of a Full-Scale Hybrid Composite Bull Gear

Hybrid composite gears have been investigated as a weight saving technology for rotorcraft transmissions. These gears differ from conventional steel gears in that the structural material between the shaft interface and the gear rim is replaced with a lightweight carbon fiber composite. The work discussed here is an extension of previous coupon level hybrid gear tests to a full-scale bull gear. The NASA Glenn Research Center High-Speed Helical Gear Rig was modified for this program allowing several hybrid gear web configurations to be tested while utilizing the same gear rim. Testing was performed on both a baseline (steel) web configuration and a hybrid (steel-composite)configuration. Vibration, orbit and temperature data were recorded and compared between configurations. Vibration levels did not differ greatly between the hybrid and steel configurations, nor did temperature differential between inlet and outlet. While orbit shape displayed differences between the hybrid and baseline configurations, the general overall amplitude was comparable. The hybrid configuration discussed here successfully ran at 3300 hp(2,460 kW), however, progressive growth of the orbit while running at this test condition discontinued the test. Researchers continue to search for the cause of this orbit shift.

Transmissions↗

Temperature-dependent reaction-rate expression for oxygen recombination at Shuttle entry conditions

A temperature-dependent oxygen surface reaction-rate coefficient has been determined from experimental STS-2 heating and wall temperature data at altitudes of 77.91 km, 74.98 km, and 71.29 km. The coefficient is presented in an Arrhenius form and is shown to be less temperature dependent than previous results. Finite-rate viscous-shock-layer heating rates based on this present expression have been compared with predicted heating rates using the previous rate coefficients and with experimental heating data obtained over an extensive range of STS-2 and STS-3 entry conditions. A substantial improvement is obtained in comparison of experimental data and predicted heating rates using the present oxygen reaction-rate expression.

Zoby, E. V.↗

Data book for 12.5-inch diameter SRB thermal model water flotation test - 14.7 psia, series P024

Tests were conducted to determine how thermal conditions affect space shuttle solid rocket booster (SRB) flotation. Acceleration, pressure, and temperature data were recorded from initial water impact to final flotation position using a 12.5-inch diameter thermal model of the SRB at ambient pressure. The model was 136.9 inches long and weighed 117.3 lbm. The tests indicated the following differences from ambient temperature tests: (1) significant negative static pressures can occur during penetration; (2) maximum penetration is increased; and (3) final flotation is in the spar buoy mode.

Allums, S. L.↗

Modeling surface temperature distributions in forest landscapes

A model of the frequency distributions of the spatial variability in surface temperature is presented. Surface temperature data are obtained from two daytime and two nighttime flights of the Thermal IR Multispectral Scanner (TIMS) over forest land in western Oregon in August, 1985. The temperature values are corrected for atmospheric attenuation and thermal radiation emission with the LOWTRAN-6 algorithm. The temperature distributions were modeled with a two-parameter beta probability density distribution and the fit of the model was evaluated by comparison with the TIMS data set. Use of the model's parameters to identify and classify surface types shows good discrimination among various surfaces for the daytime images, with less distinct discrimination for the nighttime images.

Holbo, H. R.↗

Effects of Melt Convection and Solid Transport on Macrosegregation and Grain Structure in Equiaxed Al-Cu Alloys

Macrosegregation in metal casting can be caused by thermal and solutal melt convection, and the transport of unattached solid crystals resulting from nucleation in the bulk liquid or dendrite fragmentation. To develop a comprehensive numerical model for the casting of alloys, an experimental study has been conducted to generate benchmark data with which such a solidification model could be tested. The objectives were: (1) experimentally study the effects of solid transport and thermosolutal convection on macrosegregation and grain size; and (2) provide a complete set of boundary conditions temperature data, segregation data, and grain size data - to validate numerical models. Through the control of end cooling and side wall heating, radial temperature gradients in the sample and furnace were minimized. Thus the vertical crucible wall was adiabatic. Samples at room temperature were 24 cc and 95 mm long. The alloys used were Al-1 wt. pct. Cu, and Al- 10 wt. pct. Cu; the starting point for solidification was isothermal at 710 and 685 C respectively. To induce an equiaxed structure various amounts of the grain refiner TiB2 were added. Samples were either cooled from the top, or the bottom. Several trends in the data stand out. In attempting to model these experiments, concentrating on these trends or differences may be beneficial.

Rerko, Rodney S.↗

Leaf surface temperature and sapflow raw data, 11 March 2016 - 13 June 2016, Santarem Brazil, Km67 tower

This data package contains raw, unprocessed leaf surface temperature data for five trees and sap velocity data for four trees near the Km67 flux tower in Santarem, Brazil. Data was collected over the course of three months. Datalogger output from sapflow ICT sensors was translated using ICT software and is included in the attached zip file. Raw data is in .csv and .xls formats. Leaf surface temperature sensor photos, sensor manual PDFs, and three file-level metadata excel files are also included in the attached file.

54 ENVIRONMENTAL SCIENCES↗

Potential for Small Unmanned Aircraft Systems Applications for Identifying Groundwater-Surface Water Exchange in a Meandering River Reach: sUAS in Groundwater-Surface Water Study

The exchange of groundwater and surface water (GW-SW), including dissolved constituents and energy, represents a critical yet challenging characterization problem for hydrogeologists and stream ecologists. Here we describe the use of a suite of high spatial resolution remote sensing techniques, collected using a small unmanned aircraft system (sUAS), to provide novel and complementary data to analyze GW-SW exchange. sUAS provided centimeter-scale resolution topography and water surface elevations, which are often drivers of exchange along the river corridor. Additionally, sUAS-based vegetation imagery, vegetation-top elevation, and normalized difference vegetation index mapping indicated GW-SW exchange patterns that are difficult to characterize from the land surface and may not be resolved from coarser satellite-based imagery. We combined these data with estimates of sediment hydraulic conductivity to provide a direct estimate of GW “shortcutting” through meander necks, which was corroborated by temperature data at the riverbed interface.

54 ENVIRONMENTAL SCIENCES↗

Modeling the irradiance and temperature dependence of photovoltaic modules in PVsyst

In order to reliably simulate the energy yield of photovoltaic (PV) systems, it is necessary to have an accurate model of how the PV modules perform with respect to irradiance and cell temperature. Building on previous work that addresses the irradiance dependence, two approaches to fit the temperature dependence of module power in PVsyst have been developed and are applied here to recent multi-irradiance and -temperature data for a standard Yingli Solar PV module type. The results demonstrate that it is possible to match the measured irradiance and temperature dependence of PV modules in PVsyst. As a result, improvements in energy yield prediction using the optimized models relative to the PVsyst standard model are considered significant for decisions about project financing.

14 SOLAR ENERGY↗

The thermal conductance of solid-lubricated bearings at cryogenic temperatures in vacuum

The thermal conductance of Hertzian contacts is of great importance to cryogenic spacecraft mechanisms such as the Infra-Red Space Observatory (ISO) and the Far Infra-Red Space Telescope (FIRST). At cryogenic temperatures, cooling of mechanism shafts and associated components occurs via conduction through the bearings. When fluid lubricants are cooled below their pour points, they no longer lubricate effectively, and it is necessary to use low shear strength solid lubricants. Currently, only very limited low temperature data exists on the thermal conductance of Hertzian contacts in both unlubricated and lubricated conditions. This paper reports on measurements of thermal conductance made on stationary ball bearings under cryo-vacuum conditions. Quantitative data is provided to support the development of computer models predicting the thermal conductance of Hertzian contacts and solid lubricants at cryogenic temperatures.

Anderson, M. J.↗

Evaluation of 18 Satellite- and Model-Based Soil Moisture Products Using in Situ Measurements From 826 Sensors

Information about the spatiotemporal variability of soil moisture is critical for many purposes, including monitoring of hydrologic extremes, irrigation scheduling, and prediction of agricultural yields. We evaluated the temporal dynamics of 18 state-of-the-art (quasi-)global near-surface soil moisture products, including six based on satellite retrievals, six based on models without satellite data assimilation (referred to hereafter as “open-loop” models), and six based on models that assimilate satellite soil moisture or brightness temperature data. Seven of the products are introduced for the first time in this study: one multi-sensor merged satellite product called MeMo (Merged soil Moisture) and six estimates from the HBV (Hydrologiska Byråns Vattenbalansavdelning) model with three precipitation inputs (ERA5, IMERG, and MSWEP) with and without assimilation of SMAPL3E satellite retrievals, respectively. As reference, we used in situ soil moisture measurements between 2015 and 2019 at 5 cm depth from 826 sensors, located primarily in the USA and Europe. The 3-hourly Pearson correlation (R) was chosen as the primary performance metric. We found that application of the Soil Wetness Index (SWI) smoothing filter resulted in improved performance for all satellite products. The best-to-worst performance ranking of the four single-sensor satellite products was SMAPL3E SWI , SMOS SWI , AMSR2 SWI , and ASCAT SWI , with the L-band-based SMAPL3E SWI (median R of 0.72) outperforming the others at 50 % of the sites. Among the two multi-sensor satellite products (MeMo and ESA-CCI SWI ), MeMo performed better on average (median R of 0.72 versus 0.67), probably due to the inclusion of SMAPL3E SWI . The best-to-worst performance ranking of the six open-loop models was HBV-MSWEP, HBV-ERA5, ERA5-Land, HBV-IMERG, VIC-PGF, and GLDAS-Noah. This ranking largely reflects the quality of the precipitation forcing. HBV-MSWEP (median R of 0.78) performed best not just among the open-loop models but among all products. The calibration of HBV improved the median R by +0.12 on average compared to random parameters, highlighting the importance of model calibration. The best-to-worst performance ranking of the six models with satellite data assimilation was HBV-MSWEP+SMAPL3E, HBV-ERA5+SMAPL3E, GLEAM, SMAPL4, HBV-IMERG+SMAPL3E, and ERA5. The assimilation of SMAPL3E retrievals into HBV-IMERG improved the median R by +0.06, suggesting that data assimilation yields significant benefits at the global scale.

Hylke E. Beck↗

Validation of an inverse model of zone air heat balance

Our work introduces the validation method and results of an inverse model of zone air heat balance. The inverse model, implemented in EnergyPlus and published in a previous article [1], calculates highly uncertain model parameters such as internal thermal mass and infiltration airflow by inversely solving the zone air heat balance equation using the easy-to-measure zone air temperature data. The paper provides technical details of validation from the experiments using LBNL's Facility for Low Energy eXperiment in Buildings (FLEXLAB) that measures zone air temperature under the controlled experiment of two levels of internal mass and four levels of infiltration airflow. The simulation results of the zone infiltration airflow and internal thermal mass from the inverse model agree well with the measured data from the FLEXLAB experiments. The validated inverse model in EnergyPlus can be utilized to enhance the energy modeling of existing buildings that enables energy performance assessments for energy efficiency improvements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Materials Assessment of Insulating Foam in the 9977 Shipping Package for Long-Term Storage - Annual Report

The 9977 shipping package is being evaluated for long-term storage applications in the K-Area Complex (KAC) with specific focus on the packaging foam material. A rigid closed cell polyurethane foam, LAST-A-FOAM® FR-3716, produced by General Plastics Manufacturing Company is sprayed and expands to fill the void between the inner container and the outer shell of the package. The foam is sealed in this annular space and is not accessible. During shipping and storage, the foam experiences higher than ambient temperatures from the heat generated by nuclear material within the package creating the potential for degradation of the foam. A series of experiments is underway to determine the extent of foam degradation. Foam samples of three densities have been aging at elevated temperatures 160 °F, 160 °F + 50% relative humidity (RH), 185 °F, 215 °F, and 250 °F since 2014. Samples were periodically removed and tested. After approximately 80 weeks, samples conditioned at 160 °F, 160 °F + 50% RH, and 185 °F have retained initial property values while samples conditioned at 215 °F have reduced intumescence. Samples conditioned at 250 °F have shown the most degradation, loss of volume, mass, absorbed energy under compression, intumescence, and increased flammability. Based on the initial data, temperatures up to 185 °F have not yet shown an adverse effect on the foam properties and it is recommended that exposure of FR-3716 foam to temperatures in excess of 250 °F be avoided or minimized. Testing will continue beyond the 96 week mark. This will provide additional data to help define the long-term behavior for the lower temperature conditions. Additional testing will be pursued in an attempt to identify transition points (threshold times and temperatures) at the higher temperatures of interest, as well as possible benefits of aging within the relatively oxygen-free environment the foam experiences inside the 9977 shipping package.

36 MATERIALS SCIENCE↗

Atomic density effects on temperature characteristics and thermal transport at grain boundaries through a proper bin size selection

This study focuses on the proper characterization of temperature profiles across grain boundaries (GBs) in order to calculate the correct interfacial thermal resistance (ITR) and reveal the influence of GB geometries onto thermal transport. The solid-solid interfaces resulting from the orientation difference between the (001), (011), and (111) copper surfaces were investigated. Temperature discontinuities were observed at the boundary of grains due to the phonon mismatch, phonon backscattering, and atomic forces between dissimilar structures at the GBs. We observed that the temperature decreases gradually in the GB area rather than a sharp drop at the interface. As a result, three distinct temperature gradients developed at the GB which were different than the one observed in the bulk solid. This behavior extends a couple molecular diameters into both sides of the interface where we defined a thickness at GB based on the measured temperature profiles for characterization. Results showed dependence on the selection of the bin size used to average the temperature data from the molecular dynamics system. The bin size on the order of the crystal layer spacing was found to present an accurate temperature profile through the GB. We further calculated the GB thickness of various cases by using potential energy (PE) distributions which showed agreement with direct measurements from the temperature profile and validated the proper binning. The variation of grain crystal orientation developed different molecular densities which were characterized by the average atomic surface density (ASD) definition. Our results revealed that the ASD is the primary factor affecting the structural disorders and heat transfer at the solid-solid interfaces. Using a system in which the planes are highly close-packed can enhance the probability of interactions and the degree of overlap between vibrational density of states (VDOS) of atoms forming at interfaces, leading to a reduced ITR. Thus, an accurate understanding of thermal characteristics at the GB can be formulated by selecting a proper bin size.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic ground state of La 2 LiMoO 6 : A comparison with other Mo 5+ ( S=1/2 ) double perovskites

La 2 LiMoO 6 is a double perovskite (DP) with P2 1 /n symmetry based on the Mo5+ ion, 4d1, t2g1, S=1/2. It is isostructural with Sr 2 YMoO 6 , the magnetic ground state of which is apparently a very unusual collective spin singlet or valence-bond glass state as is the case for cubic (Fm-3m) Ba 2 YMoO 6 . Initial studies of La 2 LiMoO 6 suggested a different ground state from the other DPs but no clear conclusions could be drawn. A more detailed study is presented here including magnetic susceptibility, heat capacity, and elastic neutron-scattering results. This DP is now well characterized as an antiferromagnet, T N =18K, via observation of magnetic Bragg peaks in neutron scattering and an anomaly in the magnetic heat capacity. The ordering wave vector is k=( 1/21/2 0), consistent with a type I face-centered-cubic magnetic structure, and the ordered moment on Mo 5+ is 0.32(11)μ B , much reduced from the spin-only value of 1μ B . The index, f=|v c |/T N ~3, indicates a low level of frustration. The heat-capacity data above T N can be interpreted in terms of a one-dimensional spin-correlation model, as can the low-temperature data which follow a T 1 power law. This is consistent with an earlier suggestion. The difference with isostructural Sr 2 YMoO 6 is attributed to differences in the local distortion of the Mo–O octahedron and the resulting orbital ordering.

36 MATERIALS SCIENCE↗

Thermal adaptation of soil microbial growth traits in response to chronic warming

ABSTRACT Adaptation of soil microbes due to warming from climate change has been observed, but it remains unknown what microbial growth traits are adaptive to warming. We studied bacterial isolates from the Harvard Forest Long-Term Ecological Research site, where field soils have been experimentally heated to 5°C above ambient temperature with unheated controls for 30 years. We hypothesized that Alphaproteobacteria from warmed plots have (i) less temperature-sensitive growth rates; (ii) higher optimum growth temperatures; and (iii) higher maximum growth temperatures compared to isolates from control plots. We made high-throughput measurements of bacterial growth in liquid cultures over time and across temperatures from 22°C to 37°C in 2–3°C increments. We estimated growth rates by fitting Gompertz models to the growth data. Temperature sensitivity of growth rate, optimum growth temperature, and maximum growth temperature were estimated by the Ratkowsky 1983 model and a modified Macromolecular Rate Theory (MMRT) model. To determine evidence of adaptation, we ran phylogenetic generalized least squares tests on isolates from warmed and control soils. Our results showed evidence of adaptation of higher optimum growth temperature of bacterial isolates from heated soils. However, we observed no evidence of adaptation of temperature sensitivity of growth and maximum growth temperature. Our project begins to capture the shape of the temperature response curves, but illustrates that the relationship between growth and temperature is complex and cannot be limited to a single point in the biokinetic range. IMPORTANCE Soils are the largest terrestrial carbon sink and the foundation of our food, fiber, and fuel systems. Healthy soils are carbon sinks, storing more carbon than they release. This reduces the amount of carbon dioxide released into the atmosphere and buffers against climate change. Soil microbes drive biogeochemical cycling and contribute to soil health through organic matter breakdown, plant growth promotion, and nutrient distribution. In this study, we determined how soil microbial growth traits respond to long-term soil warming. We found that bacterial isolates from warmed plots showed evidence of adaptation of optimum growth temperature. This suggests that increased microbial biomass and growth in a warming world could result in greater carbon storage. As temperatures increase, greater microbial activity may help reduce the soil carbon feedback loop. Our results provide insight on how atmospheric carbon cycling and soil health may respond in a warming world.

59 BASIC BIOLOGICAL SCIENCES↗

Thermostatic Radiator Valve Evaluation and Demonstration

A large stock of multifamily buildings in the Northeast and Midwest uses hot water or steam for space heating. Typically, residents do not pay for heat directly (i.e., heating fuel serves a central plant and use is not submetered). Losses from these systems are typically high, and a significant number of apartments are overheated much of the time. This is often evidenced by open windows on winter days. Controls and distribution are often faulty, and improving them can be more cost effective than replacing boilers. Thermostatic radiator valves (TRVs), which have been in use for many decades, are one potential strategy to combat this problem. They are commonly used in Europe and in other markets such as commercial buildings, but have not been widely accepted by the residential retrofit market in the northeastern United States. Anecdotal evidence suggests that heating systems engineers and contractors have a variety of opinions about their effectiveness, illustrating a lack of consensus on this potentially important energy efficiency measure. A review of the limited available literature revealed that, in one study, heating fuel savings as high as 15% was achieved through TRV retrofits. In this project, the U.S. Department of Energy Building America team, Advanced Residential Integrated Energy Solutions, sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt (Building Energy Optimization software). Radiator and apartment space temperature data were collected and analyzed for two similar apartment units in a building that underwent a one-pipe steam TRV retrofit. Space temperature comparisons were made across the pre- and post-TRV installation heating periods and between rooms equipped with old or new TRVs in an attempt to show the comparative effectiveness of each vintage of TRV. Analyses of the heating fuel utility bills before and after the building-wide TRV installation were conducted to quantify potential savings. The results of the field experiment and utility bill analysis did not show energy savings at either the unit or the building-wide level. The results provided inconclusive answers to the original study questions but provided valuable insight into common steam system imbalance and resident behavior issues that are critical to address in conjunction with TRV retrofits. Specific issues identified included steam distribution imbalance, possible TRV sensor location issues, a persistent window-opening habit, and a failure to optimize the boiler control set points as part of the TRV retrofit. The lack of heating fuel savings underscored the need to include whole steam system commissioning alongside or as a prerequisite to TRVs. Failed air vents and uneven steam main venting are critical to address either in conjunction with or before a TRV installation. Monitoring existing space temperatures before a retrofit strategy is chosen would allow the consultant and building owner to better assess the potential benefits of a whole-building TRV retrofit, selective installation of TRVs in some units, or simply balancing the steam distribution venting. Further gaps in the understanding of underlying processes that allow TRVs to function effectively were also identified and are presented as opportunities for future research.

Array↗