Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “technology performance level assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

FARM supervisory capabilities for thermal energy storage

The FARM (Feasible Actuator Range Modifier) module is a component of the RAVEN-based FORCE framework for the analysis of Integrated Energy Systems (IES). FARM aids HERON in the solution of the power dispatch problem by evaluating feasible set-point signals to be issued to the control systems of the different IES unit components. Set-points need to satisfy limits on both production variables (i.e., the variables to be optimized such as the electrical power, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). To enforce all these limits, a two-stage approach is adopted. First, the power dispatcher algorithm in HERON module estimates set-points that meet the constraints on the production variables, e.g., power levels and power ramp rate limits. These constraints are called explicit constraints. Then, if necessary, FARM adjusts these set-points to ensure the respect of the limits on the process variables of interest, given the knowledge of the system dynamics acquired through machine learning algorithms. These constraints are called implicit constraints. From this standpoint, FARM constitutes a bridge between the HERON power dispatcher that adopts a simplified description of the IES unit (low-resolution physics) and the HYBRID high-fidelity models (high-resolution physics). In this report, an overview of the major capabilities of the latest release of FARM is provided, along with a summary of the tool demonstration campaign conducted at the Dynamic Energy Technology and Integration Laboratory (DETAIL) facility. These results assess the performance of the control system architecture embedding FARM both as a Validator of the HERON power dispatcher and as a real time Supervisory control scheme. Additionally, the report outlines the areas that FARM might benefit from, along with proposed solutions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Revolutionary Aerospace Systems Concepts - Planning for the Future of Technology Investments

In January, 2000, the NASA Administrator gave the following directions to Langley: "We will create a new role for Langley as a leader for the assessment of revolutionary aerospace system concepts and architectures, and provide resources needed to assure technology breakthroughs will be there to support these advanced concepts. This is critical in determining how NASA can best invest its resources to enable future missions." The key objective of the RASC team is to look beyond current research and technology (R&T) programs and missions and evolutionary technology development approaches with a "top-down" perspective to explore possible new mission capabilities. The accomplishment of this objective will allow NASA to provide the ability to go anywhere, anytime - safely, and affordably- to meet its strategic goals for exploration, science, and commercialization. The RASC Team will seek to maximize the cross-Enterprise benefits of these revolutionary capabilities as it defines the revolutionary enabling technology areas and performance levels needed. The product of the RASC Team studies will be revolutionary systems concepts along with enabling technologies and payoffs in new mission capabilities, which these concepts can provide. These results will be delivered to the NASA Enterprises and the NASA Chief Technologist for use in planning revolutionary future NASA R&T program investments.

Ferebee, Melvin J., Jr.↗

Assessment of Lithium-based Battery Electrolytes Developed under the NASA PERS Program

Recently, NASA formally completed the Polymer Energy Rechargeable System (PERS) Program, which was established in 2000 in collaboration with the Air Force Research Laboratory (AFRL) to support the development of polymer-based, lithium-based cell chemistries and battery technologies to address the next generation of aerospace applications and mission needs. The goal of this program was to ultimately develop an advanced, space-qualified battery technology, which embodied a solid polymer electrolyte (SPE) and complementary components, with improved performance characteristics that would address future aerospace battery requirements. Programmatically, the PERS initiative exploited both interagency collaborations to address common technology and engineering issues and the active participation of academia and private industry. The initial program phases focused on R&D activities to address the critical technical issues and challenges at the cell level. A variety of cell and polymeric electrolyte concepts were pursued as part of the development efforts undertaken at numerous governmental, industrial and academic laboratories. Numerous candidate electrolyte materials were developed, synthesized and optimized for evaluation. Utilizing the component screening facility and the "standardized" test procedures developed at the NASA Glenn Research Center, electrochemical screening and performance evaluations of promising candidate materials were completed. This overview summarizes test results for a variety of candidate electrolyte materials that were developed under the PERS Program. Electrolyte properties are contrasted and compared to the original project goals, and the strengths and weaknesses of the electrolyte chemistries are discussed. Limited cycling data for full-cells using lithium metal and vanadium oxide electrodes are also presented. Based on measured electrolyte properties, the projected performance characteristics and temperature limitations of batteries utilizing the advanced electrolytes and components have been estimated. Limitations for the achievement of practical performance levels are also discussed, as well as needs for future research and development.

Bennett, William R.↗

Performance, Stability, and Plume Characterization of the HERMeS Thruster with Boron Nitride Silica Composite Discharge Channel

NASA's Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5kW Technology Demonstration Unit-3 (TDU-3) has been the subject of extensive technology maturation in preparation for flight system development. Detailed performance, stability, and plume characterization tests of the thruster were performed at NASA GRC's Vacuum Facility 5 (VF-5). The TDU-3 thruster implements a magnetic topology that is identical to TDU-1. The TDU-3 boron nitride silica composite discharge channel material is different than the TDU-1 heritage boron nitride discharge channel material. Performance and stability characterization of the TDU-3 thruster was performed at discharge voltages between 300V and 600V and at discharge currents between 5A and 21.8A. The thruster performance and stability were assessed for varying magnetic field strength, cathode flow fractions between 5% and 9%, varying harness inductance, and for reverse magnet polarity. Performance characterization test results indicate that the TDU-3 thruster performance is in family with the TDU-1 levels. TDU-3's thrust efficiency of 65% and specific impulse of 2,800sec at 600V and 12.5kW exceed performance levels of SOA Hall thrusters. Thruster stability regimes were characterized with respect to the thruster discharge current oscillations (discharge current peak-to-peak and root mean square magnitudes), discharge current waveform power spectral density analysis, and maps of the current-voltage-magnetic field. Stability characterization test results indicate a stability profile similar to TDU-1. Finally, comparison of the TDU-1 and TDU-3 plume profiles found that there were negligible differences in the plasma plume characteristics between the TDU with heritage boron nitride versus the boron nitride silica composite discharge channel.

ion engines↗

Detection and Perception of Sound by Eagles and Surrogate Raptors

One overarching objective of this program of study was the accumulation of objective, scientifically valid information relating to auditory performance of bald and golden eagles that may be used to guide the development of acoustic alerting/deterrence technologies intended to discourage encroachment into wind energy air spaces. To that end, analyses aimed at the characterization of sensitivity to sound in bald and golden eagles, along with findings in the supra-threshold, dynamic frequency spaces related to response latencies and amplitudes, leads us to conclude that bald, and golden eagles navigate the same basic working auditory space, as in other known and thus far characterized members of the diurnal raptor family. Specifically, bald and golden eagles, along with other raptor species within the group, operate in an auditory space characterized by a frequency band at least four octaves wide and centered on 2 kHz, with an upper frequency limit between 6 and 10 kHz at 80 dB SPL and a lower frequency limit that almost certainly extends below 0.2 kHz. Consequently, we recommend that signal designers use these data as a guideline in efforts to design effective and efficient acoustic alerting/deterrent systems. It is important to note that signal energy broadcast outside of this frequency band at moderate levels will not contribute to the efficacy of a deterrent but will add an unnecessary fraction to the overall acoustic pollution budget. The importance of this consideration is heightened by contemporaneous concerns related to the transmission of noise broadcast by wind energy farms. In addition, based on analyses of data acquired from red-tailed hawks using the same experimental paradigm and data acquisition system, we conclude that auditory function in the red-tailed hawk is sufficiently like that observed in bald and golden eagles to permit its use as a surrogate species. Response waveforms, threshold-frequency curves, and input-output characteristics match those of eagles closely. It should be noted however, that differences in sensitivity and slightly extended high-frequency limits of hearing should be taken into account when extrapolating findings from one species to the others. Although the inclusion of behavioral tests of red-tailed hawks to acoustic stimuli was beyond the scope of this investigation, future efforts to assess response parameters like signal-type preference and habituation rate will further elucidate their suitability to serve as eagle surrogates in behavioral studies; nonetheless, the species in question are well matched with respect to basic auditory performance. A second essential objective of this program of study was the acoustic characterization of a subset of calls comprising the vocal repertoires of bald and golden eagles that may be used to supplement auditory performance findings in the effort to guide the development of acoustic alerting signals. With regard to that objective, the vocal repertoires of both bald and golden eagle species are rich and varied. While similar in spectrographic structure, distinctive differences are also clear. Generally, golden eagles produce some calls with shorter durations, and similar “sounding” calls exhibit distinctively different spectrographic patterns than those of bald eagles. Both species produce calls that contain a wide variety of nonlinear elements that operate to enhance the rich and varied nature of commonly observed vocal products. Comparison of the average power spectra of commonly observed bald and golden eagle calls with threshold-frequency curves leads to the conclusion that call energies fall within the frequency bounds of hearing. Further, the acoustic energy of calls considered in this report tend to fall into overlapping, but different frequency ranges of the acoustic sensitivity curve. This condition may encourage signal designers to vary the frequency content of acoustic deterrence signals in the field. Finally, preliminary observations relating to the tendencies and proclivities of bald eagles to attend to the acoustic landscape lead to the conclusion that eagles monitor their immediate sound environment assiduously. Individuals respond to a variety of natural and synthetic sound signals reliably and, perhaps most relevant in the context of the engineering of acoustic alerting/deterrence technologies, habituation to most sounds considered in this effort was minimal. These preliminary results, while calling for extended behavioral testing, are promising and set the stage for the exportation of behavioral studies into real world scenarios.

17 WIND ENERGY↗

The Potential of Low Molecular Weight Heparin to Mitigate Cytokine Storm in Severe COVID‐19 Patients: A Retrospective Cohort Study

On March 11, 2020, the World Health Organization declared its assessment of coronavirus disease 2019 (COVID‐19) as a global pandemic. However, specific anti‐severe acute respiratory syndrome‐coronavirus 2 (SARS‐CoV‐2) drugs are still under development, and patients are managed by multiple complementary treatments. We performed a retrospective analysis to compare and evaluate the effect of low molecular weight heparin (LMWH) treatment on disease progression. For this purpose, the clinical records and laboratory indicators were extracted from electronic medical records of 42 patients with COVID‐19 (21 of whom were treated with LMWH, and 21 without LMWH) hospitalized (Union Hospital of Huazhong University of Science and Technology) from February 1 to March 15, 2020. Changes in the percentage of lymphocytes before and after LMWH treatment were significantly different from those in the control group ( P = 0.011). Likewise, changes in the levels of D‐dimer and fibrinogen degradation products in the LMWH group before and after treatment were significantly different from those in the control group ( P = 0.035). Remarkably, IL‐6 levels were significantly reduced after LMWH treatment ( P = 0.006), indicating that, besides other beneficial properties, LMWH may exert an anti‐inflammatory effect and attenuate in part the “cytokine storm” induced by the virus. Our results support the use of LMWH as a potential therapeutic drug for the treatment of COVID‐19, paving the way for a subsequent well‐controlled clinical study.

Shi, Chen↗

Development of remote sensing technology in New Zealand, part 1. Seismotectonic, structural, volcanologic and geomorphic study of New Zealand, part 2. Indigenous forest assessment, part 3. Mapping land use and environmental studies in New Zealand, part 4. New Zealand forest service LANDSAT projects, part 5. Vegetation map and landform map of Aupouri Peninsula, Northland, part 6. Geographical applications of LANDSAT mapping, part 7

The author has identified the following significant results. Inspection of pixels obtained from LANDSAT of New Zealand revealed that not only can ships and their wakes be detected, but that information on the size, state of motion, and direction of movement was inferred by calculating the total number of pixels occupied by the vessel and wake, the orientation of these pixels, and the sum of their radiance values above the background level. Computer enhanced images showing the Waimihia State Forest and much of Kaingaroa State Forest on 22 December 1975 were examined. Most major forest categories were distinguished on LANDSAT imagery. However, the LANDSAT imagery seemed to be most useful for updating and checking existing forest maps, rather than making new maps with many forest categories. Snow studies were performed using two basins: Six Mile Creek and Mt. Robert. The differences in radiance levels indicated that a greater areal snow cover in Six Mile Creek Basin with the effect of lower radiance values from vegetation/snow regions. A comparison of the two visible bands (MSS 4 and 5) demonstrate this difference for the two basins.

Probine, M. C.↗

The impact of kidney function on Alzheimer’s disease blood biomarkers: implications for predicting amyloid-β positivity

Impaired kidney function has a potential confounding effect on blood biomarker levels, including biomarkers for Alzheimer’s disease (AD). Given the imminent use of certain blood biomarkers in the routine diagnostic work-up of patients with suspected AD, knowledge on the potential impact of comorbidities on the utility of blood biomarkers is important. We aimed to evaluate the association between kidney function, assessed through estimated glomerular filtration rate (eGFR) calculated from plasma creatinine and AD blood biomarkers, as well as their influence over predicting Aβ-positivity. We included 242 participants from the Translational Biomarkers in Aging and Dementia (TRIAD) cohort, comprising cognitively unimpaired individuals (CU; n = 124), mild cognitive impairment (MCI; n = 58), AD dementia (n = 34), and non-AD dementia (n = 26) patients all characterized by [ 18 F] AZD-4694. Plasma samples were analyzed for Aβ42, Aβ40, glial fibrillary acidic protein (GFAP), neurofilament light chain (NfL), tau phosphorylated at threonine 181 (p-tau181), 217 (p-tau217), 231 (p-tau231) and N-terminal containing tau fragments (NTA-tau) using Simoa technology. Kidney function was assessed by eGFR in mL/min/1.73 m 2 , based on plasma creatinine levels, age, and sex. Participants were also stratified according to their eGFR-indexed stages of chronic kidney disease (CKD). We evaluated the association between eGFR and blood biomarker levels with linear models and assessed whether eGFR provided added predictive value to determine Aβ-positivity with logistic regression models. Biomarker concentrations were highest in individuals with CKD stage 3, followed by stages 2 and 1, but differences were only significant for NfL, Aβ42, and Aβ40 (not Aβ42/Aβ40). All investigated biomarkers showed significant associations with eGFR except plasma NTA-tau, with stronger relationships observed for Aβ40 and NfL. However, after adjusting for either age, sex or Aβ-PET SUVr, the association with eGFR was no longer significant for all biomarkers except Aβ40, Aβ42, NfL, and GFAP. When evaluating whether accounting for kidney function could lead to improved prediction of Aβ-positivity, we observed no improvements in model fit (Akaike Information Criterion, AIC) or in discriminative performance (AUC) by adding eGFR to a base model including each plasma biomarker, age, and sex. While covariates like age and sex improved model fit, eGFR contributed minimally, and there were no significant differences in clinical discrimination based on AUC values. We found that kidney function seems to be associated with AD blood biomarker concentrations. However, these associations did not remain significant after adjusting for age and sex, except for Aβ40, Aβ42, NfL, and GFAP. While covariates such as age and sex improved prediction of Aβ-positivity, including eGFR in the models did not lead to improved prediction for any biomarker. Our findings indicate that renal function, within the normal to mild impairment range, does not seem to have a clinically relevant impact when using highly accurate blood biomarkers, such as p-tau217, in a biomarker-supported diagnosis.

60 APPLIED LIFE SCIENCES↗

Enabling Staged Pressurized Oxy-Combustion: Improving Flexibility and Performance at Reduced Cost

Introduction: The staged pressurized oxy-combustion (SPOC) process, developed by Washington University in St. Louis (WUSTL), is an oxy-combustion carbon capture technology that employs a steam power cycle to generate electricity. As with atmospheric-pressure oxy-combustion processes, carbon dioxide (CO 2 ) capture rates of 90% or higher can be achieved. The staged-combustion approach of the SPOC process, when operated at elevated gas pressure, allows for near elimination of flue gas recycle (FGR) and leads to significant improvements in efficiency and reduced costs. The primary goal of this project was to investigate the potential for SPOC for flexible operation beyond the capabilities of conventional coal-fired power plants, particularly those employing carbon capture and storage (CCS). Oxy-combustion differs from conventional coal combustion in that the combustion of coal is carried out using oxygen as opposed to air. The resultant flue gas is a mixture of primarily CO 2 and water, greatly simplifying CO 2 capture. As SPOC does the oxy-combustion process under pressure, it is higher efficiency and lower cost than atmospheric oxy-combustion. The project was led by the Electric Power Research Institute, Inc., with the assistance of WUSTL, Doosan Babcock (DBL – boiler plant original equipment manufacturer), and Air Liquide (AL – air separation experts). The specific objectives of the project were to: (1) Evaluate the SPOC concept and develop a risk-based approach to the heating surface layout ensuring that performance (gas and steam side), manufacturing, transportation, and plant erection considerations were fully accounted for in the system design. (2) Improve the technology to ensure its performance and cost potential are substantially better than today’s baseline pulverized coal power plant with post-combustion capture (PCC) or atmospheric oxy-combustion, and show progress toward performance commensurate with projected commercial operation, including 90% or more CO 2 capture. (3) Address critical technology gaps and improving overall system performance for the technology. (4) Perform combustion tests at scale under commensurate pressure to the commercial operating system validate combustor and advance the SPOC combustion modeling tools that will facilitate full-scale design. Combustion Testing: Testing was initially carried out at atmospheric pressure with methane to ensure that all systems were correctly operating. Following this, the testing then proceeded to moderate pressure operation at 4 bara, where different stoichiometric conditions were used across an extended heat input range, showing that a stable flame could be maintained. Testing then proceeded at 10 and 15 bara where it was shown that the ignition system needed to be replaced at these operating conditions. When testing recommenced, a similar stable flame shape was achieved, without any methane support, and the full 100 kWth coal oxy-combustion was demonstrated. Heat flux measurements showed 400 kW/m 2 (0.126 MMBtu/hr-ft 2 ) from the flame, within the 450 kW/m 2 (0.142 MMBtu/hr-ft 2 ) preferred limit defined by DBL for the full-scale design case. Carbon monoxide and carbon-in-ash measurements showed that complete combustion was possible with ultra-low excess oxygen at 1 vol % in the product flue gas. This allowed the full-scale models to be calculated based on this level of excess oxygen, improving the performance of the system as lower feed oxygen is produced in the air separation unit (ASU), saving auxiliary power. Full-Scale Design: The full-scale design is sized to deliver 550 MWe net electrical power output to allow direct comparison with the National Energy Technology Laboratory (NETL) baseline cases using the same Montana Powder River Basin (PRB) fuel. The cases used for direct comparison are: Case S12A (supercritical [SC] coal without CO 2 capture), Case S12B (SC coal with PCC at 90% CO 2 capture, and Case S12F (atmospheric oxy-combustion SC coal with 90% CO 2 capture). The SPOC stages were configured to be identical arrangements, allowing for a more straightforward design, construction, and control strategy. Each stage consists of two PVs, the first being the combustor PV module and the second being the convective PV module. The combustor module is the tallest vessel, with local coal feeding equipment and the burner FGR and oxygen plenums at the top and ash management at the bottom. The combustor module is effectively an open cross section with membrane tubes around the circumference – this unobstructed slender profile ensures that the relatively slower burnout mechanism needed for the low-speed turbulent mixing burner can proceed unimpeded and that molten ash will not attach to any surfaces at an angle to the predominant flue gas flow. The steam turbine used in the SPOC design is essentially the same unit utilized in the atmospheric oxy-combustion case except the degree of heat recovery possible allows the low-pressure (LP) feedwater heater train to be eliminated. This is a result of being able to capture the latent heat of evaporation of the moisture produced in the combustion (normally lost to the stack). The SPOC system outperforms the NETL atmospheric oxy-combustion baseline case by 3.3% points and the PCC case by 7.5% points. This performance increase is mainly a result of the improved heat recovery possible from the product flue gas and from the reduced auxiliary power consumption from the ASU and the CO 2 compression and purification unit over the atmospheric equivalent. The combined improvement in boiler efficiency and reduction in the steam turbine heat rate resulted in a net improvement in the overall plant efficiency by 0.61%, to 35.6% on a HHV basis. This relatively small improvement in plant efficiency between sub-bituminous and bituminous coals shows the value of useful moisture latent heat recovery offered by the SPOC system when using low rank fuels. Flexibility and Turndown: The SPOC system has inherent high turndown capabilities because of a demonstrated high range of combustion stability and the ability to bypass stages, thereby reducing steam generation rates proportionally without altering firing rates in operating stages. ASU units do not generally offer significant turndown opportunities as they are limited by the performance of the compression plant. The baseline SPOC design has a 2-train ASU configuration, needed to be able to meet the 10,500 tonnes per day duty, that can deliver efficient turndown points between 85–100% load with both trains operating, and at 45–50% load with a single train operating. Outside these operating points, the flexibility and efficiency are limited and may be uncompetitive at loads below 45% as the ASU systems are unable to turndown beyond 85% for the base case and 70% for the flexible case. The ASU cold box for the flexible case was designed to operate at loads between 40-100%, below this operating range the purity of the produced oxygen cannot be guaranteed, resulting in additional load for the CPU equipment. The additional power consumption of these cases yields an uneconomic operating condition with poor efficiency when operating at low loads such as 25% and 12%. To address this flexibility constraint, AL evaluated how the ASU configuration could be altered to deliver efficient oxygen supply over the load range. This involved integrating the compressor duties across both ASU trains into a shared duty arrangement with multiple compressors, strategically sized to deliver the duty required across all load ranges between 40–100% by enabling different combinations of the main air compressors and the booster air compressors. The oxygen purity cannot be guaranteed below 40% load for each train – the power consumption at 25% and 12% loads were estimated based on the multi-compressor configuration at maximum turndown as these load cases were not considered in the flexible ASU design. With a different cold box configuration, i.e. number of trains, the entire load range could be delivered within oxygen purity specifications. Although there is a small efficiency reduction at full load, there are significant improvements in overall plant performance during low-load operation. The exact ASU configuration needed will therefore be dependent on the expected operating profile of the unit. Economic Analysis: Cost estimates for the baseline and the flexible cases were developed using NETL baseline case data for common BOP items and an Association for the Advancement of Cost Engineering International Class 5 (conceptual/screening study) assessment of key components unique to the SPOC system. The capital, operating, and maintenance costs were assessed along with the first-year power cost, levelized cost of electricity, and CO 2 captured and avoided cost for the SPOC cases were compared against the relevant NETL baseline cases in January 2019 dollars. Both SPOC cases achieve a lower cost that the alternative NETL baseline cases (with the flexible SPOC case being slightly higher than the baseline SPOC case due to the compounded impact of higher capital costs and lower efficiency at full load). The SPOC cases deliver a lower cost of CO 2 avoided than the NETL baseline cases due to greater efficiency in generating low-carbon power. However, the cost of CO 2 captured is higher because the higher efficiency of the SPOC process generates less CO 2 , hence less needs to be captured, resulting in a high capital cost being shared over a reduced CO 2 quantity. The flexible ASU adds 1.6% overall to the plant cost in comparison to the baseline case, but the efficiency improvements at loads below 50% are significant. Subsequently, depending on the plant load-profile expectation, the flexible ASU would be beneficial if the plant spends a significant portion of its operating life below 50% load. This kind of operating profile is likely to be required for all fossil plants when more renewable electricity generators are installed on the local grid, particularly solar power that can be predicted ahead of time, allowing for appropriate pricing signals to be incorporated into the diurnal cycle. R&D Recommendations: SPOC, while a promising technology, is a relatively recent concept and, as such, operability issues of combustor design and steam-side integration for such systems at a scale relevant to commercial deployment have not been evaluated. WUSTL has conducted extensive small pilot-scale (100 kWth) research to understand and advance pressurized oxy-combustion processes, including investigation of combustion and flame characteristics, radiative heat flux, burner operability, turn down, char burnout, ash characteristics, water-wash column operation, etc. for pressurized oxy-combustion systems. Nonetheless, at this stage in the development of the SPOC process, what is needed is a large-scale pilot plant that can serve to study pressurized oxy-combustion systems and components at a scale commensurate with the maturity of the technology. A scale of 10 MWth, which includes steam-side integration and two stages would yield essential information with respect to heat transfer characteristics both in the radiative and convective sections of the pressure vessels, and the ability to operate the fuel staging process. In addition, while modeling results indicate that combustion and flame characteristics improve with scale, direct studies of the combustor at this scale will ensure that the models can be relied upon for scale up to commercial scale. Furthermore, a detailed analysis must be performed to understand the scaling aspects of key components and systems.

20 FOSSIL-FUELED POWER PLANTS↗

Comprehensive Environmental Informatics System (CEIS) Integrating Crew and Vehicle Environmental Health

Integrated Vehicle Health Management (IVHM) systems have been pursued as highly integrated systems that include smart sensors, diagnostic and prognostics software for assessments of real-time and life-cycle vehicle health information. Inclusive to such a system is the requirement to monitor the environmental health within the vehicle and the occupants of the vehicle. In this regard an enterprise approach to informatics is used to develop a methodology entitled, Comprehensive Environmental Informatics System (CEIS). The hardware and software technologies integrated into this system will be embedded in the vehicle subsystems, and maintenance operations, to provide both real-time and life-cycle health information of the environment within the vehicle cabin and of its occupants. This comprehensive information database will enable informed decision making and logistics management. One key element of the CEIS is interoperability for data acquisition and archive between environment and human system monitoring. With comprehensive components the data acquired in this system will use model based reasoning systems for subsystem and system level managers, advanced on-board and ground-based mission and maintenance planners to assess system functionality. Knowledge databases of the vehicle health state will be continuously updated and reported for critical failure modes, and routinely updated and reported for life cycle condition trending. Sufficient intelligence, including evidence-based engineering practices which are analogous to evidencebased medicine practices, will be included in the CEIS to result in more rapid recognition of off-nominal operation to enable quicker corrective actions. This will result from better information (rather than just data) for improved crew/operator situational awareness, which will produce significant vehicle and crew safety improvements, as well as increasing the chance for mission success, future mission planning as well as training. Other benefits include improved reliability, increase safety in operations and cost of operations. The cost benefits stem from significantly reduced processing and operations manpower, predictive maintenance for systems and subjects. The improvements in vehicle functionality and cost will result from increased prognostic and diagnostic capability due to the detailed total human exploration system health knowledge from CEIS. A collateral benefit is that there will be closer observations of the vehicle occupants as wrist watch sized devices are worn for continuous health monitoring. Additional database acquisition will stem from activities in countermeasure practices to ensure peak performance capability by occupants of the vehicle. The CEIS will provide data from advanced sensing technologies and informatics modeling which will be useful in problem troubleshooting, and improving NASA s awareness of systems during operation.

Nall, Mark E.↗

Assessing the Benefits and Implementations of Secure Embedded Intelligence

This is a poster submission, so we do not have a formal abstract; however, we have included a couple of the main points of the poster. Motivation Current ICS/IIoT reference architectures are ill-suited to continue to meet industry demands. Architectures such as the Purdue Model and ISA-95 split cyber-physical systems into distinct levels; however, business needs and cybersecurity requirements constantly require cross-cutting solutions. Further, newly defined IIoT architectures are better suited for Industry 4.0 systems, but they leave out the feedback seen in Purdue and ISA-95. This underscores a need for new architectures, without which IT and OT boundaries will continue to grow. Secure embedded intelligence (SEI) should drive the creation of these new architectures. Secure Embedded Intelligence Advances in sensing, computation, and automated analysis have opened new possibilities for increased security, performance, and cost savings. SEI enables advanced technology to be utilized to drive new reference architectures to achieve these possibilities while integrating trust and risk.

99 GENERAL AND MISCELLANEOUS↗

Exprimental Results of the First Two Stages of an Advanced Transonic Core Compressor Under Isolated and Multi-Stage Conditions.

NASA's Environmentally Responsible Aviation (ERA) Program calls for investigation of the technology barriers associated with improved fuel efficiency for large gas turbine engines. Under ERA, the highly loaded core compressor technology program attempts to realize the fuel burn reduction goal by increasing overall pressure ratio of the compressor to increase thermal efficiency of the engine. Study engines with overall pressure ratio of 60 to 70 are now being investigated. This means that the high pressure compressor would have to almost double in pressure ratio while keeping a high level of efficiency. NASA and GE teamed to address this challenge by testing the first two stages of an advanced GE compressor designed to meet the requirements of a very high pressure ratio core compressor. Previous test experience of a compressor which included these front two stages indicated a performance deficit relative to design intent. Therefore, the current rig was designed to run in 1-stage and 2-stage configurations in two separate tests to assess whether the bow shock of the second rotor interacting with the upstream stage contributed to the unpredicted performance deficit, or if the culprit was due to interaction of rotor 1 and stator 1. Thus, the goal was to fully understand the stage 1 performance under isolated and multi-stage conditions, and additionally to provide a detailed aerodynamic data set for CFD validation. Full use was made of steady and unsteady measurement methods to understand fluid dynamics loss source mechanisms due to rotor shock interaction and endwall losses. This paper will present the description of the compressor test article and its measured performance and operability, for both the single stage and two stage configurations. We focus the paper on measurements at 97% corrected speed with design intent vane setting angles.

transonic compressors↗

Failure Analysis for Molten Salt Thermal Energy Storage Tanks for In-Service CSP Plants

Thermal Energy Storage (TES) is a fundamental component in concentrating solar power (CSP) plants to increase the plant's dispatchability, capacity factor, while reducing the levelized cost of electricity. In central receivers CSP plants, nitrate molten salts have been used for several years for operation temperatures of up to 565 degrees C. Despite many efforts to advance nitrate salt to higher operation temperatures (even considering a replacement with molten chloride salts) to achieve higher energy conversion efficiencies, the 565 degrees C temperature is currently considered the state-of-the art. Although molten salt tanks have been broadly deployed in commercial CSP plants worldwide, several failures have been reported in these tanks after a few months or years of operation, causing significant economic loss and mistrust in CSP technologies. Most of these failures are associated with the infancy of the technology and multiple issues related to tank design, fabrication, commissioning, and aggressive operation. A technical standard dedicated to the design and fabrication of molten nitrate TES tanks does not exist today. Current in-service molten salt tanks have been generally designed based on the American Petroleum Institute's (API) 650 and ASME Section II standards. The API 650 code provides guidelines for dimensions and fabrication for oil storage tanks up to 260 degrees C. The ASME standard provides allowable stress values for various materials at a range of temperatures and conditions. Both standards seem to be limited for molten salt TES tanks where high temperatures, thermal cycling, and transient conditions are expected. In 2020, NREL released the Concentrating Solar Power Best Practices Study (NREL/TP-5500-75763) that summarized multiple issues in CSP plants, along with potential alternatives and recommendations to address those issues based on information collected from participants representing about 80% of operating CSP plants in the world. One of the recommendations from this study was the development of accurate and validated models to evaluate the plant's transient operation, capable of capturing the effect of short-term clouds and operator response, while being flexible in being adapted to various spatial and temporal resource data. The "Failure Analysis for Molten Salt Thermal Energy Tanks for In-Service CSP Plants" project was inspired on this recommendation and was focused on (1) the development and validation of a physics-based model for a representative, commercial-scale molten salt tank, (2) performing simulations to evaluate the behavior of the tank as a function of typical plant operation conditions, (3) understanding tank failures mechanisms, (4) determining the residual stress and distortion in the tank floor after welding fabrication and evaluating their impact in the stresses developed in the tank during operation, (5) assessing the impact of key operation parameters on the temperature and stress distribution, (6) conduct a preliminary evaluation of design features to reduce stress and improve tank's reliability, and (7) estimate the tank's service life based on the stress developed under diverse operation scenarios. From the analysis conducted in the project and presented in this report, it was found that maximum stresses surpassing the yield strength point of the stainless steel (SS) 347H are developed on the tank floor near the perimeter. These large stresses are strongly influenced by the initial residual stresses and distortion of the tank floor after welding fabrication. During operation, large stresses are developed in the tank floor at high operation temperatures with large salt inventory levels during transient operation. High stresses are also related to elevated temperature gradients in the tank floor that could be attributed to insufficient mixing within the salt inflow and the salt inventory. Based on the analysis, creep is the predominant failure mechanism. However, the large stress levels could favor the plastic deformation into buckles, and crack formation due to stress relaxation cracking during cycle operation. A lifetime below 3 years was estimated for the typical plant operation conditions and a specific initial residual stress and deformation distribution of the tank floor. The estimated life agrees with the service time to failure reported in several commercial molten salt tanks. Desing and operation guidelines can be extracted from the analysis presented in this report, which could be adopted by tank manufacturers and CSP operators to advance toward an ultimate solution for tank failures by reducing residual and operational stresses to achieve a tank service life of more than 30 years. Addressing failures in molten salt TES tanks is fundamental for the CSP industry's survivability, but it is also important for other industrial and power generation applications using this technology, including nuclear and concentrating solar thermal.

14 SOLAR ENERGY↗

Assessment of a Conceptual Flap System Intended for Enhanced General Aviation Safety

A novel multielement trailing-edge flap system for light general aviation airplanes was conceived for enhanced safety during normal and emergency landings. The system is designed to significantly reduce stall speed, and thus approach speed, with the goal of reducing maneuveringflight accidents and enhancing pilot survivability in the event of an accident. The research objectives were to assess the aerodynamic performance characteristics of the system and to evaluate the extent to which it provided both increased lift and increased drag required for the low-speed landing goal. The flap system was applied to a model of a light general aviation, high-wing trainer and tested in the Langley 12- Foot Low-Speed Wind Tunnel. Data were obtained for several device deflection angles, and component combinations at a dynamic pressure of 4 pounds per square foot. The force and moment data supports the achievement of the desired increase in lift with substantially increased drag, all at relatively shallow angles of attack. The levels of lift and drag can be varied through device deflection angles and inboard/outboard differential deflections. As such, it appears that this flap system may provide an enabling technology to allow steep, controllable glide slopes for safe rapid descent to landing with reduced stall speed. However, a simple flat-plate lower surface spoiler (LSS) provided either similar or superior lift with little impact on pitch or drag as compared to the proposed system. Higher-fidelity studies are suggested prior to use of the proposed system.

Campbell, Bryan A.↗

Mass Modeling of NEP Power Conversion Concepts for Human Mars Exploration

The specific mass (mass per unit of electric power output) of an NEP power conversion system is an important metric for the performance and feasibility of a crewed NEP vehicle. This work explores a component level buildup of the specific mass for a crewed NEP vehicle. The buildup is highly parametric and avoids being tied to specific technologies where practical. This allows the specific mass to be calculated for a variety of assumptions and operating conditions and be used to optimize particular design variables or compare different system configurations. The values of specific mass are dependent on assumptions with significant uncertainty; comparison between cases and trends observed in the models are the main goal of the work presented here. To demonstrate the level of insight this type of modeling can provide, the impacts of compressor inlet temperature, turbine inlet temperature, and radiator pressure drop on specific mass are explored. In addition, the specific mass can be used to assess the benefit of separating the radiator and reactor loop from the power conversion cycle.

NEP↗

Mass Modeling of NEP Power Conversion Concepts for Human Mars Exploration

The specific mass (mass per unit of electric power output) of an NEP power conversion system is an important metric for the performance and feasibility of a crewed NEP vehicle. This work explores a component level buildup of the specific mass for a crewed NEP vehicle. The buildup is highly parametric and avoids being tied to specific technologies where practical. This allows the specific mass to be calculated for a variety of assumptions and operating conditions and be used to optimize particular design variables or compare different system configurations. The values of specific mass are dependent on assumptions with significant uncertainty; comparison between cases and trends observed in the models are the main goal of the work presented here. To demonstrate the level of insight this type of modeling can provide, the impacts of compressor inlet temperature, turbine inlet temperature, and radiator pressure drop on specific mass are explored. In addition, the specific mass can be used to assess the benefit of separating the radiator and reactor loop from the power conversion cycle.

nep↗

Fleet-Level Fuel Impact of Hybrid-Electric Aircraft in United States

Here, this paper examines the impact of two potential solutions for increasing fuel efficiency and reducing emissions in commercial aviation: hybrid-electric propulsion and the use of drop-in synthetic aviation fuels (SAFs). The authors modeled three representative aircraft employed in the U.S. domestic market: a 70-seat regional turboprop, a 100-seat airliner, and a 180-seat airliner. These aircraft were retrofitted with hybrid-electric propulsion systems that integrate batteries and electric motors to provide additional torque to the propeller or fan. The authors explored various technological scenarios involving different battery specific energies, electric motor specific powers, and other relevant parameters. Flight performance models were used to analyze the range–payload capabilities of these new hybrid-electric aircraft and to compare them with their conventional counterparts. Subsequently, the authors virtually deployed the hybrid-electric aircraft on 2019 U.S. domestic commercial flights to assess the types and lengths of flights that could be serviced by this new fleet. We then compared the resulting fuel consumption, energy use, and emissions with those of a conventional fleet using a combination of jet fuel and SAF.

SAF↗

Cardiovascular Adjustments to Gravitational Stress

The effects of gravity on the cardiovascular system must be taken into account whenever a hemodynamic assessment is made. All intravascular pressure have a gravity-dependent hydrostatic component. The interaction between the gravitational field, the position of the body, and the functional characteristics of the blood vessels determines the distribution of intravascular volume. In turn this distribution largely determines cardiac pump function. Multiple control mechanisms are activated to preserve optimal tissue perfusion when the magnitude of the gravitational field or its direction relative to the body changes. Humans are particularly sensitive to such changes because of the combination of their normally erect posture and the large body mass and blood volume below the level of the heart. Current aerospace technology also exposes human subjects to extreme variations in the gravitational forces that range from zero during space travel to as much an nine-times normal during operation of high-performance military aircraft. This chapter therefore emphasizes human physiology.

Blomqvist, C. Gunnar↗