Development of an integrated lightweight flexible silicon solar cell array Quarterly technical report, 1 Jan. - 1 Apr. 1970
Analysis of solar cell array systems for cost effectiveness in production and design
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Analysis of solar cell array systems for cost effectiveness in production and design
Approximate analysis of the effect of nonzero trim on planar tumbling motion of vehicle during atmospheric reentry
This final technical report contains three parts: Part 1 deals with the 2-D shell theory and its element formulation and applications. Part 2 deals with the 3-D degenerated element. These two parts constitute the two major tasks that were completed under the grant. Another related topic that was initiated during the present investigation is the development of a nonlinear material model. This topic is briefly discussed in Part 3. To make each part self-contained, conclusions and references are included in each part. In the interest of brevity, the discussions presented are relatively brief. The details and additional topics are described in the references cited.
The project team has outlined several technical objectives which will allow the companies to improve on their current capabilities. These include modifications to the imaging system, enabling it to operate more cost effectively and with greater ease of use, automation of the post-processing software to mosaic and orthorectify the image scenes collected, and the addition of radiometric calibration to greatly aid in the ability to perform accurate change detection. Business objectives include fine tuning of the market plan plus specification of future product requirements, expansion of sales activities (including identification of necessary additional resources required to meet stated revenue objectives), development of a product distribution plan, and implementation of a world wide sales effort.
This report details the data analysis results from data collected during the September-October 2019 joint survey series between the Department of Energy (DOE) National Nuclear Security Administration (NNSA) Aerial Measuring System (AMS) asset, and the Government of India’s Department of Atomic Energy (DAE) Bhabha Atomic Research Centre (BARC). This joint survey series took place at the Nevada National Security Site (NNSS), areas of public land in Southern Nevada, and at the DOE Office of Legacy Management (LM) Large Area Calibration Pads (LACP) at the Grand Junction Regional Airport in Grand Junction, CO. The data detailed in this report were gathered at the LACP. More details regarding the setup of these surveys and personnel involvement can be found in the AMS / BARC Joint Survey Summary Report. The data from the LACP collected by AMS are consistent with past data collection campaigns at the LACP. The AMS Bell 412 (B412) helicopter, equipped with both the standard AMS thallium-doped sodium iodide (NaI(Tl)) 2"x4"x16" 12-detector system and a subset of the BARC Aerial Gamma Spectroscopy System (AGSS) consisting of two independent 3"x3"cylindrical NaI(Tl) detectors, measured each of the five calibration pads for a minimum of 10 minutes. After the helicopter measurements, a pressurized ion chamber (PIC) was used to directly measure radiation exposure rates on each of the pads for a period 5 minutes. The geophysical calibration procedure published by the International Atomic Energy Agency (IAEA) (Erdi-Krausz et al. 2003) was used to determine the spectral stripping sensitivity matrix for naturally occurring radiological material (NORM). The sensitivity matrix is consistent with the AMS long term average. Additionally, the PIC data was used to calibrate the AMS system for exposure rate. The results of the exposure rate analysis are also consistent with AMS long-term averages.
The purpose of the SDAV institute is to provide tools and expertise in scientific data management, analysis, and visualization to DOE’s application scientists. Our goal is to actively work with application teams to assist them in achieving breakthrough science, and to provide technical solutions in the data management, analysis, and visualization regimes that are broadly used by the computational science community. Over the last 5 years members of our institute worked directly with application scientists and DOE leadership-class facilities to assist them by applying the best tools and technologies at our disposal. We also enhanced our tools based on input from scientists on their needs.
This slide deck report presents a literature review on virtual power plants (VPPs) and a demand flexibility analysis for the state of Virginia as part of DOE's State Energy Program (SEP) technical assistance work. The literature review describes key concepts, examples, participation models, and other issues for VPPs, and the analysis section presents a state-specific demand flexibility analysis estimating the technical potential for demand response from various sectors and end-uses. These materials are meant to inform and support VA's ability to shepherd ongoing dialogue and meet energy needs in the midst of strong load growth.
This final report summarizes NAS8-38250 contract events, 'Special Environmental Control and Life Support Systems Test Analysis and Hardware'. This report is technical and includes programmatic development. Key to the success of this contract was the evaluation of Environmental Control and Life Support Systems (ECLSS) test results via sophisticated laboratory analysis capabilities. The history of the contract, including all subcontracts, is followed by the support and development of each Task.
The Lambda Point Experiment (LPE) is one of the instruments included in the U.S. Microgravity Payload Mission 1 planned for one of the Space Shuttle flights in 1992. The objective of the experiment is to measure the heat capacity of liquid helium within a narrow interval around the transition between superfluid and normal helium (the lambda point) with an unprecedented temperature resolution of about 10 to the -10th. Multiple technical challenges are presented in the areas of structural support, safety analysis, and modal frequency tests. This paper describes the technical challenges of JPL's multidisciplinary involvement in support of these experiments in microgravity.
Near-extremal black holes are subject to large quantum effects, which modify their low-temperature thermodynamic behavior. Hitherto, these quantum effects were analyzed by separating the geometry into the near-horizon region and its exterior. It is desirable to understand and reproduce such corrections from the full higher-dimensional asymptotically flat or AdS geometry’s perspective. We address this question in this article and fill this gap. Specifically, we find off-shell eigenmodes of the quadratic fluctuation operator of the Euclidean gravitational dynamics, with eigenvalues that vanish linearly with temperature. We illustrate this for BTZ and neutral black holes with hyperbolic horizons in AdS in Einstein-Hilbert theory, and for the charged black holes in Einstein-Maxwell theory. The linear scaling with Matsubara frequency, which is a distinctive feature of the modes, together with the fact that their wavefunctions localize close to the horizon as we approach extremality, identifies them as responsible for the aforementioned quantum effects. We provide a contour prescription to deal with the sign indefiniteness of the Euclidean Einstein-Maxwell action, which we derive to aid our analysis. We also resolve a technical puzzle regarding modes associated with rotational isometries in stationary black hole spacetimes.
Background: Using myocardial perfusion scintigraphy (MPS), an increase in left ventricular (LV) volumes or a decrease in ejection fraction (EF) from rest to stress may be clinically important. The variation in these measures between the low-dose stress acquisition and high-dose rest acquisition in a one-day stress-rest protocol has not been established. We assessed the reproducibility of gated volumetric indices between stress and rest and the normal variation in ungated TID ratio for a one-day stress-rest {sup 99m}Tc-tetrofosmin protocol. Methods: Two thousand and one hundred and fifty eight (2158) {sup 99m}Tc-tetrofosmin MPS patient studies were analyzed retrospectively. Studies were excluded for incomplete data, significant technical difficulties, or (for gated analysis but not for analysis of TID ratio) if the LV EF was > 75%. An analysis of gated data was undertaken to establish the reproducibility of ventricular volumes and EF between stress and rest scans. Ungated volume data were analyzed to determine the confidence limits of TID ratio according to ventricular volume. Results: Gated data were analyzed for 621 patients without inducible hypoperfusion. Mean EF at rest was slightly higher than after stress (62.4% ± 10.3% vs 61.2% ± 10.4%, P < 0.001), and the standard deviation of the difference was 5.2% (95% CI 4.9% to 5.5%). Ungated volumes were available for 992 non-ischaemic patients. The upper 95% CI for TID ratio was 1.23. This increased from 1.20 to 1.37 between the highest and lowest deciles of rest ungated volume. Conclusion: Using a one-day stress-rest {sup 99m}Tc-tetrofosmin protocol, a fall in LV EF between rest and stress of > 11.6% or a TID ratio of > 1.23 is likely to be clinically reliable. The upper limit of normal for TID ratio needs to be increased for patients with small LV chamber volumes.
Permanent magnets can provide static magnetic fields without power supplies or feed lines, offering a simpler alternative to conventional electromagnets in tokamaks. This work examines permanent magnet arrays (PMAs) for edge localized mode (ELM) control in double-null (DN) configurations, where traditional RMP coils exhibit limited effectiveness. Linear plasma response calculations using IPEC assess high-field-side (HFS) permanent magnet placement, benchmarking performance against DIII-D low-field-side (LFS) internal coils (I-coils) while evaluating engineering constraints. Modeling results demonstrate that HFS permanent magnet configurations generate HFS plasma response amplitudes more than 5 times larger than conventional I-coil systems. While other resonant response metrics show comparable or reduced response relative to I-coils, the combination of conventional RMP systems and permanent magnets is expected to provide enhanced performance. Operational impact assessments of persistent magnetic fields, including sideband field effects and startup/ramp-up compatibility, reveal acceptable performance within established operational boundaries. This analysis establishes PMAs as a technically viable approach for DN ELM control with reductions in system complexity, motivating further experimental validation on existing tokamak facilities.
The Material Plasma Exposure eXperiment (MPEX) has been proposed as a facility to address plasma material interaction knowledge gaps to qualify and develop materials and technologies that surround plasma environments for future fusion reactors. Utilizing different radio-frequency (rf) heating technologies, MPEX is a linear plasma device that will generate fusion reactor–like plasmas with energies and particle fluxes at the target materials with electron temperatures of 1 to 15 eV, electron densities of 10 20 to 10 21 m -3 , and ion fluxes greater than 10 24 m -2 s -1 . Starting with the MPEX requirements with respect to magnetic fields between 0.1 and 2.5 T and warm bores of either 0.65 m or 1.56 m, conceptual designs for a superconducting magnet system have been developed that utilize multiple NbTi windings distributed across seven cryostats to accommodate rf heating, water cooling, and vacuum systems needed for MPEX. While the cryogenic and magnet technologies relative to the field and space requirements are mature, the integration of these technologies across multiple cryostats presents several technical and logistical challenges. An analysis of the preferred refrigeration approach, modular recondensing liquid helium cryocoolers, was performed. Utilizing a design margin of a factor of two, this approach is feasible within the current design requirements for MPEX with some considerations related to its implementation within the thermal shields and the magnet subsystem geometries.
Directly visualizing the trajectories of chemistry can unravel novel insights into the behavior of catalysts, gas phase reactions, photo-induced dynamics, and building blocks for quantum information processing. The ability of explicitly identifying, tracking, and tagging the exchange of matter, hence the annihilation and creation of new chemical species, can be best realized through a close coupling of theory and experiment. While the synchrotron-based characterization facilities propelled rapidly in its hardware, providing higher brightness, better resolution, and more precision, the software infrastructure is lagging. We developed DTCS (Digital Twin for Chemical Science) v.01, a central platform that faithfully mimics advanced instrumentations in Scientific User Facilities, by solving a variety of technical challenges in data acquisition, analysis, and model-driven interpretation. Rooted in physics and accelerated by AI, we validated this concept by direct comparison with precise experimental X-ray Photoelectron Spectroscopy (XPS) observations using a ubiquitous metal-water interfacial scenario, i.e., Ag/H2O as our main narrative. The DTCS v.01 input mirrors how the bench chemists work, with the output directly linked to the end station computer, thereby providing a user-friendly, knowledge-driven, and accessible user experience with mechanistic insights standardized in a way that are ready to be published, versioned, and transferred flexibly.
Auditory steady-state responses (ASSRs) are ongoing evoked brain responses to continuous auditory stimuli that play a role for auditory processing of complex sounds and speech perception. Transient auditory event-related responses (AERRs) have previously been recorded using fetal magnetoencephalography (fMEG) but involve different neurological pathways. Previous studies in children and adults demonstrated that the cortical components of the ASSR are significantly affected by state of consciousness and by maturational changes in neonates and young infants. To our knowledge, this is the first study to investigate ASSRs in human fetuses. 47 fMEG sessions were conducted with 24 healthy pregnant women in three gestational age groups (30–32 weeks, 33–35 weeks and 36–39 weeks). The stimulation consisted of amplitude-modulated (AM) tones with a duration of one second, a carrier frequency (CF) of 500 Hz and a modulation frequency (MF) of 27 Hz or 42 Hz. Both tones were presented in a random order with equal probability adding up to 80–100 repetitions per tone. The ASSR across trials was quantified by assessing phase synchrony in the cortical signals at the stimulation frequency. Ten out of 47 recordings were excluded due to technical problems or maternal movements. Analysis of the included 37 fetal recordings revealed a statistically significant response for the phase coherence between trials for the MF of 27 Hz but not for 42 Hz. An exploratory subgroup analysis moreover suggested an advantage in detectability for fetal behavioral state 2F (active asleep) compared to 1F (quiet asleep) detected using fetal heart rate. In conclusion, this pilot study is the first description of a method to detect human ASSRs in fetuses. The findings warrant further investigations of the developing fetal brain.
Computed tomography and special core analysis data associated with the technical report series document Computed Tomography Scanning and Geophysical Measurements of the Enhanced Geothermal Systems (EGS) Collab SURF Core. Paronish, T.; Mackey, P.; Schmitt, R.; Crandall, D.; Moore, J.; Brown, S.; Roggenthen, W.; Schwering, P. C.; Dobson, P. F.; Kneafsey, T. Computed Tomography Scanning and Geophysical Measurements of the Enhanced Geothermal Systems (EGS) Collab SURF Core; DOE.NETL-2021.2866; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2022; p 76.
Thirty individual items at the Chemistry and Metallurgy Research (CMR) facility with accountable amounts of 242 Pu required assay by gamma ray spectrometry in order to establish their masses with reasonable precision. There were two phases to this measurement campaign: 1) a preliminary screening phase in which each item was measured for a short 600 second count time to establish the relative masses between similar or like items, and 2) a second phase in which groups of items were counted for a considerably longer time in order to establish the group mass of 242 Pu in a reasonable time frame. The data from the two phases were assessed in a manner that allowed the project team to assign a 242 Pu mass to each individual item in the inventory, with the exception of three column tubes that could not be measured individually because of radiological contamination issues. The project team performed technical analyses with the SNAP™ analysis routine, PC-FRAM plutonium isotopic routine, and the NEN-2 PeakEasy routine. When total measurement uncertainties are factored in, the individual mass quantities calculated for all samples are statistically equivalent to the expected mass of 0.88 grams of total plutonium per sample.
The 2 qt SAVY nuclear material storage container is the latest in the SAVY-4000 series. The 2 qt design is identical to the 1 qt container, with the exception of an extended, deep-drawn body. Here, a technical basis using engineering equivalency analysis, calculation, and test data is presented to establish that the 2 qt SAVY-4000 Container is a DOE Manual 441.1-1 compliant container and that a fifteen-year design life (as with the currently approved SAVY series) is justified.