Revenue Analysis for Energy Storage Systems in the United States

In this work we evaluate the potential revenue from energy storage using historical electricity prices, forward-looking projections of hourly electricity prices, and actual reported revenue. This analysis examines the impact of storage characteristics, specifically duration and round-trip efficiency, as well as locational elements of storage revenue within the current and projected U.S. power system. Figure ES-1 illustrates the revenue for a 1 MW storage system in seven market regions with durations range from 1 hour to 12 hours using both historical and forward-looking price data. The historical analysis covers more than 500 price nodes for each market region, while the forward-looking analysis includes balancing areas under different 10 scenarios of the electricity generation mix. The results indicate that the revenues consistently increase with duration, though the marginal value declines as duration grows. Moreover, the range of revenue depends on the system's operational location, and the electricity generation mix changes for future years. This range also widens with increased durations. In addition, the sensitivity analysis of round-trip efficiency reveals that as efficiency improves, system revenue increases, though the value of better round-trip efficiency declines as at higher efficiency levels.

25 ENERGY STORAGE↗

Performing k eff Validation of As-Loaded Criticality Safety Calculations Using UNF-ST&DARDS: Applicable Experiment Selection

The general method for performing validation of as loaded criticality safety calculations using UNF ST&DARDS is presented in a paper by Clarity, which includes a description of the UNF-ST&DARDS system. Proof-of-principle analyses were performed in the summer of 2019 for MPC-32 dual purpose canisters (DPCs) containing pressurized water reactor (PWR) fuel assemblies. Summaries of these results are presented in this and a companion paper for this conference. The current paper describes the TSUNAMI-IP calculations performed to select applicable experiments for validation of 11 MPC-32 DPCs. The companion paper discusses the TSUNAMI-3D calculations used to generate sensitivity data to support the experiment selections discussed here. Experiment selection is based on the sensitivity/uncertainty (S/U) methods used to validate criticality safety calculations of as-loaded DPCs containing pressurized water reactor (PWR) spent nuclear fuel (SNF). This process has been demonstrated and is summarized in this paper. The approach is similar to that used in NUREG/CR-7109, which provides an approach for validation of PWR burnup credit (BUC), including major and minor actinides and major fission products. The premise of S/U-based validation is that applicable experiments—those having a similar bias to a given application system—will have similar sensitivities for each isotope and reaction in the two systems. It is assumed that cross sections with larger uncertainties are more likely to contain data errors which contribute to the bias. The integral index c k thus propagates the system sensitivities with the nuclear covariance data to calculate a correlation coefficient representing the similarity of the two systems. In this work, a c k value of 0.8 or higher is interpreted as identifying an experiment with sufficient similarity for use in validation. This paper presents a brief summary of the characteristics of the 11 MPC-32 DPCs used in the proof of-principle analysis for as-loaded criticality safety calculation validation and an overview of the critical experiment suite with which each of these DPC models was compared. A summary and discussion of c k results is also presented, followed by conclusions and a discussion of future work to be performed for validation of UNF ST&DARDS as-loaded criticality safety calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluating advanced nuclear fission technologies for future decarbonized power grids

Advanced nuclear fission, which encompasses various innovative nuclear reactor designs, could contribute to the decarbonization of the United States electricity sector. However, little is known about how cost-competitive these reactors would be compared to other technologies, or about which aspects of their designs offer the most value to a decarbonized power grid. We employ an electricity system optimization model and a case study of a decarbonized U.S. Eastern Interconnection circa 2050 to generate initial indicators of future economic value for advanced reactors and the sensitivity of future value to various design parameters, the availability of competing technologies, and the underlying policy environment. These results can inform long-term cost targets and guide near-term innovation priorities, investments, and reactor design decisions. We find that advanced reactors should cost $\$5.7$–$\$7.3$/W to gain an initial market share (assuming 30 year asset life and 3.5 %–6.5 % real weighted average cost of capital), while those that include thermal storage in their designs can cost up to $\$6.0$/W–$\$7.7$/W (not including cost of storage). Since the marginal value of advanced fission reactors declines as market penetration increases, break-even costs fall ~32 % at 100 GW of cumulative capacity and ~51 % at 300 GW. Additionally, policies that provide investment tax credits for nuclear energy create the most favorable environment for advanced nuclear fission. In conclusion, these findings can inform near-term resource allocation decisions by stakeholders, innovators and investors working in the energy technology sector.

Capacity expansion↗

DSO+T: Integrated System Simulation (DSO+T Study: Volume 2)

This report summarizes an integrated co-simulation model used by the Distribution System Operator with Transactive (DSO+T) study to represent an electrical generation, delivery, and end-load systems for the purposes of assessing the viability and value proposition of transactive energy coordination of flexible assets versus a business-as-usual case. The integrated co-simulation model includes the bulk generation and transmission system, including the day-ahead and real-time scheduling and dispatch of thermal generators. Forty distribution system operators were modelled in detail, including tens of thousands of residential and commercial buildings and their flexible end-loads. These included HVAC systems, residential water heaters, electric vehicles, and stationary, behind-the-meter, batteries. Both wholesale market and end-load results for the business-as-usual case are presented and compared to actual ERCOT system data to assess the accuracy and representativeness of the resulting model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Response of a quantum disordered spin system to a local periodic drive

We consider a one-dimensional spin chain system with quenched disorder and in the presence of a local periodic drive. We study the time evolution of the system in the Floquet basis and evaluate the fidelity susceptibility, which is a measure of how a given state changes under a small perturbation, of states to a weak periodic drive. In this work, we demonstrate that the statistical properties of the fidelity susceptibility over different disorder realizations can be used to identify two phases of the system: (1) the many-body localized phase, in which the susceptibility exhibits long tails while its average value decreases rapidly as disorder increases, and (2) the ergodic phase, in which the susceptibility distribution is narrow and its average value weakly depends on disorder. This distinction in the average value of the susceptibility between the two phases develops readily for systems with ten or more spins. Therefore, recently built networks of qubits subject to a local drive can simulate dynamics of a system in the many-body localization regime. We also show that the spin accumulation speed is correlated with the fidelity susceptibility and can also be used to distinguish the two phases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Soil Environmental Conditions in the East River Watershed, CO

This dataset contains depth-resolved soil environmental variables collected between June 2016 and October 2018 from the Bradley Meadow site in the East River watershed. Datalogger output from 7 Campbell CS655 12 cm Soil Moisture and Temperature Sensors including depth, temperature, volumetric water content, and electrical conductivity are included in ‘BM_Merged_T_VWC_0616_10_18.csv’. Sensors were installed in June 2016. Data have been processed to merge raw sensor data and to remove additional variables. No additional QA/QC was performed. Measured pCO2 and depth are contained in ‘BM_EGM_WELL_CO2.csv’. These data represent gas well samples measured via injection using a PP Systems EGM-5 infra-red gas analyzer as described in the methods section. Measured CO2 surface flux values are contained in 'BM_EGM_Surface_Flux.csv'. These were measured using the PP Systems EGM-5 with the Soil Respiration Chamber attachment. Multiple reps are reported for each measurement including CO2 flux rate calculations using built-in linear and quadratic function methods, and average and standard deviations are taken across all reps and calculation methods.

54 ENVIRONMENTAL SCIENCES↗

Grid Resilient, Self-Powered, Fuel Flexible, High Efficiency Heating System (Final Report)

The Grid Independent High Efficiency System (GIHES) delivers a heating system that operates free from the power grid and provides ultra-low emissions and high efficiency heating for residential and commercial buildings. The project demonstrated two weeks of continuous grid independent operation of a storage water heater equipped with a powered damper. The Thermoelectric Generator (TEG) integrated GIHES technology revolutionizes heating systems to provide grid resilient hot water production, while delivering significant value to the end user by eliminating impacts of power interruption and enhancing comfort, convenience and productivity. The system maximizes the thermal-to-electric conversion efficiency by optimizing location and orientation of the TEGs and durability while lowering system costs. The TEGs generate enough power to charge a battery and run the storage water heater unit with a powered damper uninterrupted by providing the required parasitic electrical power for start-up, shutdown and during idling. Several TEGs were analytically and experimentally evaluated based on the size, surface area and the power being generated before designing and fabricating a complete multi-TEG assembly for integration with the water heater. The GIHES technology can be extended to boilers, furnaces and tankless water heaters and integrated with heat pump to further increase the overall equipment efficiency. The technology has the potential to reduce the amount of dispatch power and peak power plant operation. An advanced burner was designed, developed and 3D printed for fuel flexible operation. The burner was designed to enable tighter integration with TEGs for potentially higher TEG output, should this be necessary. A bench-scale test rig to perform testing of a 200,000 Btu/h burner and capable of handling up to 10% H2 (by volume) was setup at GTI’s laboratory with appropriate safety and controls to ensure smooth and safe operation. Testing of the 3D burner showed < 5 ppm NOx emissions can be achieved for the entire firing range and with different levels of hydrogen blends with natural gas. The burner will enable a more integrated TEG-burner module design for improved system performance, should this be required in the future. Techno-economic analysis (TEA) of the TEG integrated with the water heaters was performed. The testing data and the power output were used to develop the TEA. The analysis for the storage unit with damper showed that the TEG integrated system costs $95. This is much lower than a one-time charge needed to wire and install dedicated power. Discussions with TEG manufacturers and OEM’s will provide more detailed information and methods to further lower these costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual sensor supervised learning for cyber-attack neutralization

An industrial asset may have monitoring nodes that generate current monitoring node values. A dynamic, resilient estimator may split a temporal monitoring node space into normal and one or more abnormal subspaces associated with different kinds of attack vectors. According to some embodiments, a neutralization model is constructed and trained for each attack vector using supervised learning and the associated abnormal subspace. In other embodiments, a single model is created using out-of-range values for abnormal monitoring nodes. Responsive to an indication of a particular abnormal monitoring node or nodes, the system may automatically invoke the appropriate neutralization model to determine estimated values of the particular abnormal monitoring node or nodes (e.g., by selecting the correct model or using out-of-range values). The series of current monitoring node values from the abnormal monitoring node or nodes may then be replaced with the estimated values.

97 MATHEMATICS AND COMPUTING↗

Fleet-wide Electrification Impacts Assessment for the Valley Transportation Authority

This report explores the long-term electrification opportunities for the Valley Transit Authority’s (VTA) transit bus fleet. The potential for transit bus electrification at VTA as well as the economic impacts of partial and complete electrification are explored. We use the Revenue Operation and Device Optimization model to determine the optimal charging, operation and lowest capital and operating cost solution to achieve different levels of electrification to meet their existing routes. This study finds that, relying on only depot charging, around 70% of the daily trips by VTA’s transit bus fleet can be replaced with battery electric buses (BEBs) today. The benefits and drawbacks of five methods for improving the electrification potential beyond that achievable with only depot charging are discussed including (1) increase charger power, (2) purchase of larger vehicle batteries, (3) en-route charging, (4) purchasing additional buses and swapping them to enable the existing routes/blocks1 to be met, and (5) route/block redesign. A strategy is developed to enable full fleet electrification by increasing charger power or allowing intraday charging as a proxy for the options mentioned above. This method allows us to develop an understanding of the impacts and trade-offs of full fleet electrification. Two charging strategies are examined. Immediate charging, when the bus is charged as soon as it arrives at a depot or en-route charging station, and smart charging, which uses a controller to determine the best times to charge to achieve the lowest charging cost, while maintaining the same trip schedules. Smart charging is effective at reducing the peak power consumption, which can be reduced by between 31% and 65% compared to immediate charging. This translates directly to lower electricity demand charges and lower costs for possible distribution system upgrades. The total lifetime net present value (NPV) costs for different scenarios are presented in Figure ES-1. Scenarios are separated into three sections. The first stacked bar on the left is the base case (business-as-usual) where all buses are diesel hybrids, the next four bars include partial and full fleet electrification utilizing only immediate charging, and the last four bars include partial and full fleet electrification utilizing smart charging. The results show that smart charging scenarios are within ±4% of the lifetime NPV cost of the diesel-hybrid only (business-as-usual) scenario. The scenarios with full fleet electrification (i.e., including intraday charging) are 4% lower cost and those with partial fleet electrification (i.e., without intraday charging) are 2%–3% higher. However, it is important to note that the intraday charging scenarios do not include any additional costs for the equipment necessary to achieve intraday charging (e.g., additional chargers, larger batteries, new route design). Additionally, it is worth noting that the Low Carbon Fuel Standard (LCFS) credit received for implementing electric buses is essential to achieving these results.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluation of Hybrid FPOG Applications in Regulated and Deregulated Markets Using HERON

Recent changes in the U.S. energy market, such as low natural gas prices and increased electricity production for variable renewable energy (VRE) sources, have led to an economic crisis for existing light-water reactor (LWR) nuclear power plants (NPP). Many owners and operators of LWRs have elected to decommission these plants rather than continue using them as consistent sources of clean baseload power. This has led to exploration of various possibilities to increase the economic viability of these units, including market restructuring to monetize benefits LWRs already provide to the grid through ancillary markets, load following and economic dispatch, and possible integration of secondary systems directly to the NPP for production of additional products through technologies such as hydrogen electrolysis or water desalination. Previous studies have considered the technologies associated with these Integrated Energy Systems (IES) activities, and the analysis of markets for these secondary products. To analyze the economic viability of various system configurations including IES, especially given the uncertainty surrounding load demand, electricity prices, and the availability of VRE resources, the stochastic technoeconomic analysis package HERON (Heuristic Energy Resource Optimization Network) was released earlier this year as an extension of the risk analysis framework RAVEN (Risk Analysis Virtual Environment). HERON focuses foremost on making the complex uncertainty quantification analysis tools approachable for energy systems analysts, also providing general dispatch optimization algorithms for those workflows. HERON continues to be improved and tested as a significant part of the IES viability analyses performed in this work. HERON is not a capacity expansion model. To consider market and grid energy system development in a variety of scenarios, HERON is best used in coupling with modelling tools such as US-REGEN, which sacrifice some of the uncertainty analysis and resolution of HERON's modelling for the ability to efficiently predict the change in the grid energy system's profile due to economic drivers over decades. HERON can then use this information to explore the economic viability of introducing changes to the predicted outcomes, such as the introduction of an IES. In this work, experts at EPRI using US-REGEN provide six projection scenarios for use in HERON stochastic technoeconomic analysis (STEA) in considering the options available for increasing LWR economic viability through introduction of a hydrogen-centric IES using a high-temperature steam electrolysis plant (HTSE), hydrogen storage, and a constant-rate contracted hydrogen consumer. The results obtained are differential in nature; they do not report expected profits for any configuration, but rather report on the possible increase in the NPV of a configuration with respect to a baseline no-IES configuration. Due to the uncertainty captured in the variable net load of the systems, there is likewise uncertainty in the mean values reported. We consider this viability both in terms of a regulated market, where the energy producers and IES are owned and operated by single entity, as well as a deregulated market, where the IES chooses its bid for electricity generation and is then dispatched by the grid system operator. Results indicate that for deregulated markets, the inclusion of the IES is often statistically beneficial. This is especially true in policies that are not favorable towards nuclear, as nuclear is less often dispatched and is forced to deal with frequent idle capacity. In the nominal case as well as the case of carbon tax policies, inclusion of the IES clearly benefited the economic performance of the NPP. In the regulated case, however, there was a trend towards minimizing the IES, likely due to the optimal sizing performed by US-REGEN of the NPP within the system as well as the lack of penalty for idle capacity at the NPP in the regulated market analyses.

99 GENERAL AND MISCELLANEOUS↗

Locational Value of Distributed Energy Resources

This report focuses on potential DER benefits for distribution systems, primarily in their role as non-wires alternatives to defer, mitigate, or eliminate the need for some traditional system investments at locations where distribution capacity is insufficient to meet expected future needs. It describes approaches and tools to estimate the locational value of DERs. The report includes 24 case studies to illustrate how states and utilities are considering the locational value of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

OPALCO - Decatur Island Solar and Energy Storage Project: An Assessment of Battery Technical Performance

Orcas Power & Light Cooperative (OPALCO) is a member-owned, nonprofit cooperative utility that provides energy services to approximately 11,200 customers across 20 islands in San Juan County, Washington. OPALCO’s mostly hydroelectric power is generated by Bonneville Power Administration and delivered to the islands by submarine cables. In 2016, as part of the second round of funding from the Washington state Clean Energy Fund, OPALCO received a $1 million matching grant to support a project that deployed a 504-kW LG community photovoltaic (PV) system in combination with a 1 MW/2 MWh lithium-iron-phosphate battery energy storage system (BESS) on Decatur Island, Washington. The Decatur Island Substation is essential to ensuring reliable energy for the residents of the San Juan Islands as it is the point of interconnection with the mainland transmission system. The BESS, in combination with the community solar array, will deliver an innovative method to both defer the costly upgrade of the transmission system and allow for other high-value applications intended to benefit the utility and its customers. In 2018, Pacific Northwest National Laboratory (PNNL) completed a preliminary economic assessment for several identified use cases in collaboration with OPALCO. Between August 2021 and May 2022, extensive testing was conducted, and the results were used to assess the technical performance of the BESS subjected to actual field operations. Both reference performance and use case tests were performed: (a) Reference performance tests assess the general technical capabilities of the BESS, such as energy capacity, round-trip efficiency (RTE), ramp rate, and signal tracking capability. These are the first tests performed (baseline) and are repeated after use case tests (post cycle). A standardized U.S. Department of Energy (DOE) energy storage performance protocol was used to characterize the BESS, including representative duty cycle profiles, test procedure guidance, and calculation guidance for determining key characteristics. (b) Use case tests examine the performance of the BESS for specific use cases using duty cycles developed by PNNL in collaboration with OPALCO. Four use cases were selected for testing: 1) demand charge reduction, 2) load shaping, 3) outage mitigation, and 4) transmission deferral. The use case duty cycles were developed based on utility and site-specific characteristics in addition to the technical characteristics and physical capabilities of the BESS. Use case tests were performed between the baseline and post cycle tests. This report describes the BESS and its components, presents testing and performance analysis results, and shares key insights and lessons learned from this project. Outcomes of the tests and analyses will help OPALCO understand the performance of the Decatur Island BESS in its current state and design appropriate operational strategies for this and other BESSs over the long term.

14 SOLAR ENERGY↗

Fault isolation and fault-tolerant control for Takagi-Sugeno fuzzy time-varying delay stochastic distribution systems

A fault isolation, estimation, and fault-tolerant control (FTC) scheme for nonlinear time-varying delay stochastic distribution control systems was presented in this paper. The Takagi-Sugeno fuzzy model was adopted to approach the nonlinear dynamics of time-varying delay systems. According to the output equivalence principle and Laplace transformation, an augmented state vector was given to solve the time-varying delay problem. When multiple actuator faults and interference occur simultaneously, fault detection, isolation and fault estimation was designed to obtained the fault information. To decouple faults and obtain the value and location information of the fault, the system was separated into two parts through the designed multiple conversion matrices, in which one subsystem was only affected by one actuator fault. This has simplified the design of fault isolation and estimation. A adaptive observer for fault estimation was given. Then, fault information such as the time, location, and size was determined. The observer gain matrices were calculated using linear matrix inequality (LMI). When a fault was detected and diagnosed, a FTC algorithm was devised using the proportional-integral control scheme to compensate the fault as much as possible. It has been shown that even if multiple faults actuator occurred simultaneously, the FTC controller still ensured the output probability density function of the system traced the desired probability density function when a fault occurred. Finally, the expected results were obtained through the simulation example, which confirmed the effectiveness of the method.

42 ENGINEERING↗

Estimating time in quantum chaotic systems and black holes

We characterize new universal features of the dynamics of chaotic quantum many-body systems, by considering a hypothetical task of "time estimation". Most macroscopic observables in a chaotic system equilibrate to nearly constant late-time values. Intuitively, it should become increasingly difficult to estimate the precise value of time by making measurements on the state. We use a quantity called the Fisher information from quantum metrology to quantify the minimum uncertainty in estimating time. Due to unitarity, the uncertainty in the time estimate does not grow with time if we have access to optimal measurements on the full system. Restricting the measurements to act on a small subsystem or to have low computational complexity leads to results expected from equilibration, where the time uncertainty becomes large at late times. With optimal measurements on a subsystem larger than half of the system, we regain the ability to estimate the time very precisely, even at late times. Hawking's calculation for the reduced density matrix of the black hole radiation in semiclassical gravity contradicts our general predictions for unitary quantum chaotic systems. Hawking's state always has a large uncertainty for attempts to estimate the time using the radiation, whereas our general results imply that the uncertainty should become small after the Page time. This gives a new version of the black hole information loss paradox in terms of the time estimation task. By restricting to simple measurements on the radiation, the time uncertainty becomes large. This indicates from a new perspective that the observations of computationally bounded agents are consistent with the semiclassical effective description of gravity.

Black holes↗

Self-compression of laser pulses in a discrete medium

Using the discrete nonlinear Schrödinger equation, we study the laser radiation self-action dynamics in a nanostructured waveguide system. It is shown that for a laser pulse energy exceeding the critical value, the nonlinear evolution of the wave field markedly differs from the corresponding process in a continuous medium. While the pulse propagates in a discrete medium, its length decreases to values comparable to the scale of the structure and the velocity decreases to zero. The system parameters are determined at which the wave field after the laser pulse termination begins to propagate in the opposite direction in a compressed form. The process of slowing down and stopping the pulse is accompanied by strong radiation losses, so that about a third of the energy of the initial field distribution remains in the final compressed state. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the Verification of Deep Reinforcement Learning Solution for Intelligent Operation of Distribution Grids

Capabilities of deep reinforcement learning (DRL) in obtaining fast decision policies in high dimensional and stochastic environments have led to its extensive use in operational research, including the operation of distribution grids with high penetration of distributed energy resources (DER). However, the feasibility and robustness of DRL solutions are not guaranteed for the system operator, and hence, those solutions may be of limited practical value. This paper proposes an analytical method to find feasibility ellipsoids that represent the range of multi-dimensional system states in which the DRL solution is guaranteed to be feasible. Empirical studies and stochastic sampling determine the ratio of the discovered to the actual feasible space as a function of the sample size. In addition, the performance of logarithmic, linear, and exponential penalization of infeasibility during the DRL training are studied and compared in order to reduce the number of infeasible solutions

Hosseini, Mohammad Mehdi↗

Physics-guided Deep Learning for Power System State Estimation

In the past decade, dramatic progress has been made in the field of machine learning. This paper explores the possibility of applying deep learning in power system state estimation. Traditionally, physics-based models are used including weighted least square (WLS) or weighted least absolute value (WLAV). These models typically consider a single snapshot of the system without capturing temporal correlations of system states. In this paper, a physics-guided deep learning (PGDL) method is proposed. Specifically, inspired by autoencoders, deep neural networks (DNNs) are used to learn the temporal correlations. The estimated system states from DNNs are then checked against physics laws by running through a set of power flow equations. Hence, the proposed PGDL is both data-driven and physics-guided. The accuracy and robustness of the proposed PGDL method are compared with traditional methods in standard IEEE cases. Simulations show promising results and the applicability is further discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DSO+T: Valuation Methodology and Economic Metrics (DSO+T Study: Volume 4)

This report summarizes a rigorous valuation analysis methodology used by the Distribution System Operator with Transactive (DSO+T) study to estimate the financial benefits and costs of adopting Transactive Energy coordination of distributed energy resources for key stakeholders (for example distribution system operators and customers). This was achieved by modeling the value exchanges between stakeholders and determining the annualized costs and revenues experienced by stakeholders, enabling the evaluation of overall impact on stakeholder’s annualized cash flow. Extensive work was conducted developing methods to estimate the operating costs of distribution system operators at a level of granularity that would allow the financial impact of implementing a transactive energy approach to be estimated. This work included developing parametric models for labor and software costs, distribution system capital and maintenance costs, growth rates, and factors to determine annualized costs of capital investments. Simulation results were used to calculate wholesale energy costs and revenues from retail sales. Valuation analysis methods were also developed for other stakeholders including customers, the transmission system operator, independent system operator, and generators. The resulting capability allows a complete mapping of the flow of financial value between stakeholders that can be directly integrated with the results of demand flexibility simulations. Example results are provided for a business-as-usual case and compared to a transactive energy case as well as to actual cost data.

24 POWER TRANSMISSION AND DISTRIBUTION↗