Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrum monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

FERMI OBSERVATIONS OF GRB 090510: A SHORT-HARD GAMMA-RAY BURST WITH AN ADDITIONAL, HARD POWER-LAW COMPONENT FROM 10 keV TO GeV ENERGIES

We present detailed observations of the bright short-hard gamma-ray burst GRB 090510 made with the Gamma-ray Burst Monitor (GBM) and Large Area Telescope (LAT) on board the Fermi observatory. GRB 090510 is the first burst detected by the LAT that shows strong evidence for a deviation from a Band spectral fitting function during the prompt emission phase. The time-integrated spectrum is fit by the sum of a Band function with E{sub peak} = 3.9 {+-} 0.3 MeV, which is the highest yet measured, and a hard power-law component with photon index -1.62 {+-} 0.03 that dominates the emission below {approx}20 keV and above {approx}100 MeV. The onset of the high-energy spectral component appears to be delayed by {approx}0.1 s with respect to the onset of a component well fit with a single Band function. A faint GBM pulse and a LAT photon are detected 0.5 s before the main pulse. During the prompt phase, the LAT detected a photon with energy 30.5{sup +5.8}{sub -2.6} GeV, the highest ever measured from a short GRB. Observation of this photon sets a minimum bulk outflow Lorentz factor, {Gamma}{approx_gt} 1200, using simple {gamma}{gamma} opacity arguments for this GRB at redshift z = 0.903 and a variability timescale on the order of tens of ms for the {approx}100 keV-few MeV flux. Stricter high confidence estimates imply {Gamma} {approx_gt} 1000 and still require that the outflows powering short GRBs are at least as highly relativistic as those of long-duration GRBs. Implications of the temporal behavior and power-law shape of the additional component on synchrotron/synchrotron self-Compton, external-shock synchrotron, and hadronic models are considered.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantified Event Automata: Towards Expressive and Efficient Runtime Monitors

Runtime verification is the process of checking a property on a trace of events produced by the execution of a computational system. Runtime verification techniques have recently focused on parametric specifications where events take data values as parameters. These techniques exist on a spectrum inhabited by both efficient and expressive techniques. These characteristics are usually shown to be conflicting - in state-of-the-art solutions, efficiency is obtained at the cost of loss of expressiveness and vice-versa. To seek a solution to this conflict we explore a new point on the spectrum by defining an alternative runtime verification approach.We introduce a new formalism for concisely capturing expressive specifications with parameters. Our technique is more expressive than the currently most efficient techniques while at the same time allowing for optimizations.

state machines↗

Time Series Evaluation of Portal Monitor Data

Radiation portal monitors screen cargo and personal vehicle traffic at international border crossings to detect and interdict illicit sources which may be present in the commerce stream. One difficulty faced by RPM systems is the prospect of false alarms, or undesired alarms due to background fluctuation, or Naturally-Occurring Radioactive Material (NORM) sources in the commerce stream. In general, NORM alarms represent a significant fraction of the nuisance alarms at international border crossings, particularly with Polyvinyl-Toluene (PVT) RPM detectors, which have only very weak spectral differentiation capability. With PVT detectors, the majority of detected photon events fall within the Compton continuum of the material, allowing for very little spectral information to be preserved [1]. Previous work has shown that these detectors can be used for limited spectroscopy, utilizing around 8 spectral bins to further differentiate some NORM and other nuisance sources [2]. NaI based systems achieve much more detailed spectral resolution from each measurement of a source, but still combine all measurements over a vehicle's occupancy in order to arrive at a spectrum to be analyzed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Early Characterization of Irradiation Effects in Stainless Steels at the Experimental Breeder Reactor-II

The new Global Nuclear Energy Partnership (GNEP) program is revitalizing interest in materials development for fast spectrum reactors. With this comes the need for new, high-performance materials that are resistant to property changes caused by radiation damage. In the 1970s there was an effort to monitor the irradiation effects on stainless steels used in fast reactor cores, largely because there were a number of ‘surprises’ where materials subjected to a high flux of fast neutrons incurred dimensional and property changes that had not been expected. In the U.S., this applied to the Experimental Breeder Reactor-II. Void swelling and irradiation-induced creep caused dimensional changes in the reactor components that shortened their useful lifetime and impacted reactor operations by creating fuel handling difficulties and reactivity anomalies. The surveillance programs and early experiments studied the simplest of austenitic stainless steels, such as Types 304 and 304L stainless steel, and led to some basic understanding of the links between these irradiation effects and microchemical changes within the steel caused by operational variables such as temperature, neutron flux and neutron fluence. Some of the observations helped to define later alloy development programs designed to produce alloys that were much more resistant to the effects of neutron irradiation.

36 MATERIALS SCIENCE↗

Unusual Black Hole Binary LMC X-3: A Transient High-mass X-Ray Binary That Is Almost Always On?

We have analyzed a rich, multimission, multiwavelength data set from the black hole X-ray binary (BHXB) LMC X-3, covering a new anomalous low state (ALS), during which the source flux falls to an unprecedentedly low and barely detectable level, and a more normal low state. Simultaneous X-ray and UV/optical monitoring data from Swift are combined with pointed observations from the Rossi X-ray Timing Explorer (RXTE) and X-ray Multi-Mirror Mission (XMM-Newton) and light curves from the Monitor of All-Sky X-ray Image (MAXI) instrument to compare the source characteristics during the ALS with those seen during the normal low state. An XMM-Newton spectrum obtained during the ALS can be modeled using an absorbed power law with Γ=1.41±0.65 and a luminosity of 7.97×10{sup 33} erg s{sup −1} (0.6–5 keV). The Swift X-ray and UV light curves indicate an X-ray lag of ∼8 days as LMC X-3 abruptly exits the ALS, suggesting that changes in the mass accretion rate from the donor drive the X-ray lag. The normal low state displays an asymmetric profile in which the exit occurs more quickly than the entry, with minimum X-ray flux a factor of ∼4300 brighter than during the ALS. The UV brightness of LMC X-3 in the ALS is also fainter and less variable than during normal low states. The existence of repeated ALSs in LMC X-3, as well as a comparison with other BHXBs, implies that it is very close to the transient/persistent X-ray source dividing line. We conclude that LMC X-3 is a transient source that is almost always “on.”.

79 ASTRONOMY AND ASTROPHYSICS↗

A second generation expert system for checking and diagnosing AXAF's electric power system

AXAF - Advanced X-ray Astrophysics Facility - is a third NASA's great space observatory. Each of these observatories is intended to cover different parts of the electromagnetic spectrum (x-ray for AXAF) and to provide high resolution images of celestial sources in our universe. While the spacecraft is in orbit, the electric power system (EPS) performance is monitored via sensors measuring voltages, currents, pressures, and temperatures. The sensor data are sent from the spacecraft to the ground station as telemetry and analyzed on arrival. Monitoring, diagnosis and maintenance of such EPS is an arduous task which requires expertise and constant attention of the ground personnel. To help the ground crew in this task, much of it should be automated and delegated to expert systems, which draw engineer's attention to possible malfunctions and allows him to review the telemetry to determine the source of the trouble, diagnose the suspected fault and to propose a corrective action. Those systems are built on assumptions such as: (1) domain knowledge is available and can be represented as a set of rules; (2) domain knowledge is circumscribed, static, and monotonic; and (3) expert decision making can be emulated by a logical inference mechanism.

Bykat, Alex↗

Measurement Sets and Sites Commonly Used for High Spatial Resolution Image Product Characterization

Scientists within NASA's Applied Sciences Directorate have developed a well-characterized remote sensing Verification & Validation (V&V) site at the John C. Stennis Space Center (SSC). This site has enabled the in-flight characterization of satellite high spatial resolution remote sensing system products form Space Imaging IKONOS, Digital Globe QuickBird, and ORBIMAGE OrbView, as well as advanced multispectral airborne digital camera products. SSC utilizes engineered geodetic targets, edge targets, radiometric tarps, atmospheric monitoring equipment and their Instrument Validation Laboratory to characterize high spatial resolution remote sensing data products. This presentation describes the SSC characterization capabilities and techniques in the visible through near infrared spectrum and examples of calibration results.

Pagnutti, Mary↗

Methods and apparatus for mid-infrared sensing

A chip-scale, air-clad semiconductor pedestal waveguide can be used as a mid-infrared (mid-IR) sensor capable of in situ monitoring of organic solvents and other analytes. The sensor uses evanescent coupling from a silicon or germanium waveguide, which is highly transparent in the mid-IR portion of the electromagnetic spectrum, to probe the absorption spectrum of fluid surrounding the waveguide. Launching a mid-IR beam into the waveguide exposed to a particular analyte causes attenuation of the evanescent wave's spectral components due to absorption by carbon, oxygen, hydrogen, and/or nitrogen bonds in the surrounding fluid. Detecting these changes at the waveguide's output provides an indication of the type and concentration of one or more compounds in the surrounding fluid. If desired, the sensor may be integrated onto a silicon substrate with a mid-IR light source and a mid-IR detector to form a chip-based spectrometer.

54 ENVIRONMENTAL SCIENCES↗

Results of South-East Flux Trap Dosimetry Measurements for the Advanced Test Reactor Critical Facility in support of Advanced Sensors and Instrumentation Development

Reactor dosimetry measurements are commonly used to validate simulation and modeling in nuclear reactor tests. Numerous standard dosimeter materials exist which are commonly utilized with sensitivities to different energy ranges of neutrons. At the Advanced Test Reactor (ATR), cobalt alloy and pure nickel wires are installed every cycle to monitor thermal- and fast-neutron fluence rates. However, there is growing interest in exploring less commonly used materials which are either more sensitive to different parts of the neutron energy spectrum or which can incorporate multiple activation paths in a single material. Epithermal and fast-neutron energies beyond the typical 1-MeV threshold are of particular interest. Two ATR-C Flux Runs took place during 2024; each flux run included supplemental dosimetry packages in the South-East Flux Trap (SEFT) Filler. The focus of the dosimetry package for flux run 23-4 was to test two novel dosimetry methods that can provide simultaneous thermal and threshold (fast) sensitivity in a single dosimeter wire. A selection of 3% Au in Cu alloyed wires were available that provided sensitivity to fast and thermal neutrons through 5 different reactions. Likewise, Fe offers multiple interaction pathways with sensitivity to both thermal and fast neutrons. The main question to be answered by these irradiations was if sufficient radioactivation would take place in the ATR-C SEFT during a nominal 20-minute irradiation at typical power levels (near 600Wth) to observe the threshold reactions that have smaller activation cross-sections than the thermal reactions without being saturated by interfering interactions and Compton continuum during the High-Purity Germanium (HPGe) measurements. The results from comparing the measurement results to anticipated activity levels provide confidence in our ability to activate both traditional and novel dosimetry materials in ATR-C, however not all the measured values matched with the predicted activities. This leaves further room for investigation both on the experimental and computational approaches for future irradiation experiments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Development of a piezopolymer pressure sensor for a portable fetal heart rate monitor

A piezopolymer pressure sensor has been developed for service in a portable fetal heart rate monitor, which will permit an expectant mother to perform the fetal nonstress test, a standard predelivery test, in her home. Several sensors are mounted in an array on a belt worn by the mother. The sensor design conforms to the distinctive features of the fetal heart tone, namely, the acoustic signature, frequency spectrum, signal amplitude, and localization. The components of a sensor serve to fulfill five functions: signal detection, acceleration cancellation, acoustical isolation, electrical shielding, and electrical isolation of the mother. A theoretical analysis of the sensor response yields a numerical value for the sensor sensitivity, which is compared to experiment in an in vitro sensor calibration. Finally, an in vivo test on patients within the last six weeks of term reveals that nonstress test recordings from the acoustic monitor compare well with those obtained from conventional ultrasound.

Heart Rate, Fetal/physiology↗

iPTF Discovery of the Rapid “Turn-on” of a Luminous Quasar

We present a radio-quiet quasar at z = 0.237 discovered “turning on” by the intermediate Palomar Transient Factory (iPTF). The transient, iPTF 16bco, was detected by iPTF in the nucleus of a galaxy with an archival Sloan Digital Sky Survey spectrum with weak narrow-line emission characteristic of a low-ionization nuclear emission-line region (LINER). Our follow-up spectra show the dramatic appearance of broad Balmer lines and a power-law continuum characteristic of a luminous (L{sub bol}≈10{sup 45} erg s{sup −1}) type 1 quasar 12 yr later. Our photometric monitoring with PTF from 2009–2012 and serendipitous X-ray observations from the XMM-Newton Slew Survey in 2011 and 2015 constrain the change of state to have occurred less than 500 days before the iPTF detection. An enhanced broad Hα/[O iii] λ5007 line ratio in the type 1 state relative to other changing-look quasars also is suggestive of the most rapid change of state yet observed in a quasar. We argue that the >10 increase in Eddington ratio inferred from the brightening in UV and X-ray continuum flux is more likely due to an intrinsic change in the accretion rate of a preexisting accretion disk than an external mechanism such as variable obscuration, microlensing, or the tidal disruption of a star. However, further monitoring will be helpful in better constraining the mechanism driving this change of state. The rapid “turn-on” of the quasar is much shorter than the viscous infall timescale of an accretion disk and requires a disk instability that can develop around a ∼10{sup 8} M{sub ⊙} black hole on timescales less than 1 yr.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapid Monitoring and Defense Approach for Resilience Improvement of Grid Cyber Security

Cyber-physical systems and electric utilities significantly depend on the reliability and efficiency of information and operational technology. However, false data injection attacks based on synchrophasor measurement data pose a serious threat to the safe and reliable operation of modern power systems. Here, to mitigate this problem, a rapid monitoring and defense approach is proposed to defend against cyber attacks. Initially, the Time and Frequency based Convolutional neural Network (TFCN) is proposed to detect different types of attacks. Within the TFCN, the advances are that both time and frequency domain information can be fused without extra spectrum analysis methods, and can save detection time to speed the calculation efficiency using the developed time-frequency block. Next, a comprehensive defense strategy is developed for multiple cyber attacks to ensure the stability and resilience of the power system according to the feedback detection results. The advances of this strategy are that different control strategies can be automatically selected to recover the stability to the greatest extent according to the detected attacks. To verify the effectiveness of the proposed approach, the high-speed frequency measurements collected from the wide-area monitoring system are used. The results demonstrate that the cyber attack detection performance can reach 95.57% accuracy, outperforming both traditional and some advanced neural networks. Importantly, the defense strategy is conducted and verified in a modified IEEE 39 bus system as well, which illustrates profound performance in faster stability restoration.

Comprehensive defense strategy↗

Monitoring Human Performance on Future Deep Space Missions Abstract

NASA and the commercial spacecraft community are working diligently to put the first woman on the moon in the 2024 timeframe. At the same time, NASA researchers are thinking about how to solve the even larger challenges that future deep space missions will bring. Space travel itself is difficult, but astronauts on deep space missions will face obstacles and unknowns never before experienced. In addition to the altered gravity and hostile/closed environment of a spacecraft, deep space crews will face increased radiation, isolation, and distance from Earth. During Extravehicular Activity (EVA, or “spacewalk”) operations, crew will experience increased physical and cognitive workload due to extended types, frequencies and durations of tasks performed on exploration missions in partial gravity environments. All of these stressors will impact crew physical and mental health and performance in difficult-to-anticipate ways. Crew autonomy may be one of the biggest challenges faced. Communication delays and blackouts will occur, and in those situations, the crew may not have access to the Mission Control Center (MCC). They may be forced to be solely dependent on each other and the available information onboard to stay alive, healthy, and achieve the mission. The only conceivable way to meet the challenges of Earth independence is to enable the crew to monitor their own health and performance -- preferably unobtrusively as they perform their duties. Technologies and techniques must be developed to aid the crew in these assessments. A deep space mission is expected to have relatively short periods of high cognitive demand, stress, and fatigue, alongside potentially long periods of cognitive underload during the transit, where boredom, loneliness, and depression can set in. Both ends of this spectrum are dangerous. Crew must be made aware when their task performance drops significantly, when their cognitive workload is too high, when they have lost situation awareness, or when they are too stressed or too fatigued to perform well. They must be able to identify these risks, and then mitigate them with countermeasures available onboard. A number of self-monitoring technologies are presently being explored by NASA to advance crew state determination capabilities. These range from real-time, physiological workload and situation awareness assessments, to crew health measurements determining physical and mental fitness for duty, to task performance metrics such as suit resource expenditures. For EVA tasks during surface exploration missions, biomedical information such as metabolic rate may be provided to crewmembers for situational awareness related to task performance efficiency. In addition, translation distances, hydration, nutrition, inspired CO2 exposure and other consumables usage rates may be useful input metrics for modeling individualized performance during tasks to inform crew or provide estimates of work efficiency. Oculomotor metrics such as gaze dwell time, pupilometry, and eye tracking collected in advanced helmet mounted displays could potentially be used to characterize crew situation awareness. This paper highlights some of these projects, and provides broader discussion about the need for advanced monitoring and smart technologies, as NASA takes the leap into the next generation of space exploration.

Kritina Holden↗

Acoustic Monitor for Particle Size and Bed Friction in a Carbonate Fluidized Bed at High Temperature - 18014

Previous work has shown that acoustic spectra of fluidized bed pressure fluctuations show many useful bed properties [1-3]. This current work further explores the use of acoustic monitors for an 18' diameter, 66-74'' height fluidized bed at >640 deg. C. This process denitrates and agglomerates an injected sodium/aluminum nitrate aqueous simulant and produces at steady-state a denitrated product of 200-300 micron sodium carbonate/aluminate particles. The fluidized bed shows characteristic acoustic resonances around 1-2 Hz in the FFT (Fast Fourier Transform) of pressure fluctuations for each of three taps at fluidized bed heights of 12'', 39'', and 58''. The acoustic resonance spectra depend on a bed friction that once calibrated, monitors the HMPD (harmonic mass mean particle diameter or Sauter mean diameter) along with other important bed properties. This fluidized bed operates at high temperature with an evolving HMPD that can be steady state with an appropriate superficial spatial velocity (SSV). The acoustic FFT integrated power spectrum, IPS, of pressure fluctuations represents the bed-friction damped RMS (root mean square) pressure fluctuations at each tap. The transition from a static to fluidized bed at each bed height occurs when the damped bed RMS pressure fluctuations are greater than the static head (the FFT zero Hz designated zero Hz proportional to FFT zero Hz) at that bed height. A bed will de-fluidize and become static at a bed height when bed friction completely dampens the RMS pressure fluctuations, which occurs for decreasing particle size among other factors. The ratio IPS/zero Hz then provides a continuous monitor of bed friction damping as well as particle size as the HMPD. Since HMPD and bed friction damping are both very important parameters for fluidized particle beds, the acoustic HMPD and bed friction damping both provide very useful monitors for fluidized bed operation. Such acoustic monitors have shown that they are especially sensitive to the presence of very fine particles in the bed of less than 50 microns diameter. Acoustic monitors for particle size and bed friction damping will be very useful in any fluidized bed, especially fluidized beds where particle size changes. The fluidized bed friction damping depends on many other bed properties besides particle size such as bed height, density, SSV, void fraction, gas viscosity, and fluidization scheme and so acoustic bed friction should also be useful for monitoring other bed properties besides particle size. In fact, the change in the static bed friction slope with SSV upon fluidization follows the Ergun function and reveals a minimum fluidization velocity for each HMPD. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Visible to near-infrared luminescence properties of Nd{sup 3+}-doped La{sub 2}BaZnO{sub 5} phosphor

La{sub 2}BaZnO{sub 5}:Nd{sup 3+} phosphors are synthesized by a conventional high temperature solid state reaction method, and its crystal structure and luminescence properties are investigated. Photoluminescence bands peaking at ∼496, 540, 630, 670, 905, 1070, and 1350 nm of La{sub 2}BaZnO{sub 5}:Nd{sup 3+} phosphors are observed at room temperature due to f–f transition of Nd{sup 3+} ion. The optimum Nd{sup 3+} doped concentration is ∼0.03. Lifetimes of La{sub 1.97}BaZnO{sub 5}:0.03Nd{sup 3+} phosphor with 496 and 1070 nm monitoring wavelengths are ∼280 and 250 µs, respectively. The luminescence mechanism is explained by using simplified energy lever diagram of Nd{sup 3+} ion. La{sub 2}BaZnO{sub 5}:Nd{sup 3+} material can be applied to powerful solid-state lasers as high efficient light sources. - Graphical abstract: PL spectra of La{sub 2}BaZnO{sub 5}:Nd{sup 3+} phosphor in the visible and near-infrared regions and their corresponding to PLE at room temperature. - Highlights: • La{sub 2}BaZnO{sub 5}:Nd{sup 3+} phosphor is synthesized. • PL spectrum is observed in the visible region. • PL spectrum is observed in the near-infrared region.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anticoincidence analysis for radioxenon detection

A number of beta-gamma coincidence detectors have been deployed for monitoring nuclear explosions. When 133Xe is present in a sample it causes interference in the calculation of the metastable isotopes. Therefore, an alternative method for activity quantification is to analyze the anticoincidence spectrum of the plastic detector to decrease interference from 133Xe. Simulated and experimental measurements were tested. The results show that the anticoincidence analysis produces more accurate results when quantifying the activity of 131mXe but is sometimes limited by the background increasing the minimum detectable activity.

Sivels, Ciara B.↗

Dissociation Dynamics and Electronic Structures of Highly Excited Ferrocenium Ions Studied by Femtosecond XUV Absorption Spectroscopy

In this work, the dissociation dynamics of ferrocene are explored following strong field ionization using femtosecond time-resolved extreme ultraviolet (XUV) transient absorption spectroscopy. Employing transitions in the vicinity of the iron 3p (M 2,3 ) edge, the dissociation is monitored from the point of view of the iron atom. With low strong field pump intensities (≈2 × 10 13 W cm -2 ), only ferrocenium cations are produced, and their iron 3p absorption spectrum is reported. It very closely resembles the 3p spectrum of atomic Fe + ions but is red-shifted by 0.8 eV. With the aid of time-dependent density functional theory calculations, the spectrum is assigned to a combination of doublet and quartet spin states of ferrocenium ions. Ionization with more intense strong field pump pulses (≥6 × 10 13 W cm –2 ) leads predominantly to the prompt production of ferrocenium ions that dissociate to give the spectral signature of bare Fe + ions within 240 ± 80 fs. Within the temporal resolution of the experiment (≈40 fs), no spectral intermediates are observed, suggesting that the dissociation process occurs directly from the excited ferrocenium ion and that the bonds between the iron center and both cyclopentadienyl rings are broken almost simultaneously in an asynchronous concerted decay process. Finally, no evidence of slower dissociation channels is observed at a pump–probe delay of 250 ps, suggesting that all energy is very rapidly routed into dissociative states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EVIDENCE FOR A PHOTOSPHERIC COMPONENT IN THE PROMPT EMISSION OF THE SHORT GRB 120323A AND ITS EFFECTS ON THE GRB HARDNESS-LUMINOSITY RELATION

The short GRB 120323A had the highest flux ever detected with the Gamma-Ray Burst Monitor on board the Fermi Gamma-Ray Space Telescope. Here we study its remarkable spectral properties and their evolution using two spectral models: (1) a single emission component scenario, where the spectrum is modeled by the empirical Band function (a broken power law), and (2) a two-component scenario, where thermal (a Planck-like function) emission is observed simultaneously with a non-thermal component (a Band function). We find that the latter model fits the integrated burst spectrum significantly better than the former, and that their respective spectral parameters are dramatically different: when fit with a Band function only, the E{sub peak} of the event is unusually soft for a short gamma-ray burst (GRB; 70 keV compared to an average of 300 keV), while adding a thermal component leads to more typical short GRB values (E{sub peak} {approx} 300 keV). Our time-resolved spectral analysis produces similar results. We argue here that the two-component model is the preferred interpretation for GRB 120323A based on (1) the values and evolution of the Band function parameters of the two component scenario, which are more typical for a short GRB, and (2) the appearance in the data of a significant hardness-intensity correlation, commonly found in GRBs, when we employee two-component model fits; the correlation is non-existent in the Band-only fits. GRB 110721A, a long burst with an intense photospheric emission, exhibits the exact same behavior. We conclude that GRB 120323A has a strong photospheric emission contribution, observed for the first time in a short GRB. Magnetic dissipation models are difficult to reconcile with these results, which instead favor photospheric thermal emission and fast cooling synchrotron radiation from internal shocks. Finally, we derive a possibly universal hardness-luminosity relation in the source frame using a larger set of GRBs (L{sub i}{sup Band} = (1.59 {+-} 0.84) x 10{sup 50} (E{sub peak,i}){sup 1.33{+-}0.07} erg s{sup -1}), which could be used as a possible redshift estimator for cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗