Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Finite-Test-Case Development to Demonstrate Logical Integrity of Software in DRPS

Reactor protection system (RPS) in nuclear power plant (NPP) is in the process of digitalization in response to advanced features of digital systems. In this context, software integrity in the RPS becomes an important issue since it may cause common-cause failure. Therefore, to guarantee the safety of NPPs, the integrity of the software need to be properly demonstrated or assessed. There are three typical approaches for software reliability quantification: software reliability growth model (SRGM), Bayesian belief network (BBN), and test-based method. Basically, SRGM is difficult to apply to the safety-critical software because not only sufficient failure sets are unavailable but consequence of system failure is also unacceptable. Then the result obtained through the BBN model may have large uncertainty, so it produces difficulties in integrity demonstration of safety-critical software. Thus, the BBN result need to be complemented or verified by test-based method. Currently, for the integrity demonstration of safety-critical software, black-box test which feeds inputs and examines just outputs whether they succeeded or failed is considered based on trajectory-form-of-input (a series of successive values for the input variables that occur during the operation of the software over time). Usually these trajectory-inputs are randomly sampled from operational profile. In this approach, however, there are some practical difficulties. Therefore, we proposed a new test method for safety-critical software in digitalized reactor protection system (DRPS). The main contents described in this paper are about basic concepts under development of finite-test-cases by which the integrity of the software logic can be verified. It should be noted that the influence of the environments, such as operating system and other hardware, are not considered since the method focuses on software logic only. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

LANSCE Drift Tube Linac Water Control System Refurbishment

There are several refurbishment projects underway at the Los Alamos National Laboratory LANSCE linear accelerator. Systems involved are: RF, water cooling, networks, diagnostics, timing, controls, etc. The Drift Tube Linac (DTL) portion of the accelerator consists of four DTL tanks, each with three independent water control systems. The systems are about 40 years old, use outdated and non-replaceable equipment and NIM bin control modules, are beyond their design life and provide unstable temperature control. Insufficient instrumentation and documentation further complicate efforts at maintaining system performance. Detailed design of the replacement cooling systems is currently in progress. Previous design experience on the SNS accelerator water cooling systems will be leveraged, see the SNS DTL FDR. Plans call for replacement of water piping, manifolds, pumps, valves, mix tanks, instrumentation (flow, pressure and temperature) and control system hardware and software. This presentation will focus on the control system design with specific attention on planned use of the National Instruments Compact RIO platform with the Experimental Physics and Industrial Control system (EPICS) software toolkit.

Accelerator Design, Technology, and Operations↗

SNS BLM SYSTEM EVOLUTION: DETECTORS, ELECTRONICS AND SOFTWARE

SNS is a high intensity hadron beam facility; so the Beam Loss Monitor (BLM) system is a crucial part of Machine Protection System and an important tool for beam tuning. The paper presents the current status of installed detectors and experimental data obtained during SNS operations. We compare several different types of BLMs and show advantages and disadvantages of each type. The electronic parts obsolescence became a real issue since the original electronics was designed about 10 years ago. The first test of our next generation BLM system is expected to be done by summer 2009. The new system will contribute to significant noise reduction and will follow a modular concept of Smart Device to achieve a higher degree of reliability and maintainability.

Zhukov, Alexander P↗

System and methods for hardware-software cooperative pipeline error detection

An error reporting system utilizes a parity checker to receive data results from execution of an original instruction and a parity bit for the data. A decoder receives an error correcting code (ECC) for data resulting from execution of a shadow instruction of the original instruction, and data error correction is initiated on the original instruction result on condition of a mismatch between the parity bit and the original instruction result, and the decoder asserting a correctable error in the original instruction result.

97 MATHEMATICS AND COMPUTING↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Containerization in ATLAS Software Development and Data Production

The ATLAS experiment's software production and distribution on the grid benefits from a semi-automated infrastructure that provides up-to-date information about software usability and availability through the CVMFS dis-tribution service for all relevant systems. The software development process uses a Continuous Integration pipeline involving testing, validation, packag-ing and installation steps. For opportunistic sites that can not access CVMFS, containerized releases are needed. These standalone containers are currently created manually to support Monte-Carlo data production at such sites. In this paper we will describe an automated procedure for the containerization of AT-LAS software releases in the existing software development infrastructure, its motivation, integration and testing in the distributed computing system.

97 MATHEMATICS AND COMPUTING↗

SAPHIRE 8 New Features and Capabilities

The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) software performs probabilistic risk assessment (PRA) calculations. SAPHIRE is used in support of NRC’s risk-informed programs such as the Accident Sequence Precursor (ASP) program, Management Directive 8.3, “NRC Incident Investigation Program,” or the Significance Determination Process (SDP). It is also used to develop and run the Standardized Plant Analysis Risk (SPAR) models. SAPHIRE Version 8 is a new version of the software with an improved interface and capabilities to support risk-informed programs. SAPHIRE Version 8 is designed to easily handle larger and more complex models. Applications of previous SAPHIRE versions indicated the need to build and solve models with a large number of sequences. Risk assessments that include endstate evaluations for core damage frequency and large, early release frequency evaluations have greatly increased the number of sequences required. In addition, the complexity of the models has increased since risk assessments evaluate both potential internal and external events, as well as different plant operational states. Special features of SAPHIRE 8 help create and run integrated models which may be composed of different model types. SAPHIRE 8 includes features and capabilities that are new or improved over the current Version 7 to address the new requirements for risk-informed programs and SPAR models. These include: • Improved User Interfaces • Model development • Methods • General Support Features

97 MATHEMATICS AND COMPUTING↗

INITIAL COMMISSIONING EXPERIENCE WITH THE SPALLATION NEUTRON SOURCE VERTICAL TEST AREA RF SYSTEM

The Spallation Neutron Source (SNS) has developed a vertical test area (VTA) for the testing and qualification of superconducting radio frequency cavities. The associated RF System successfully supported the initial commissioning of the VTA system and has been utilized for cavity testing at both 4 and 2 K. As operational experience was gained, improvements to the RF system were implemented to better utilize the dynamic range of the system, and software updates and additions were made to meet operational needs. The system continues to evolve as we gain better understanding of the testing needs.

Crofford, Mark↗

SU-E-T-465: Implementation of An Automated Collision Detection Program Using Open Source Software for the Pinnacle Treatment Planning System

Purpose: Potential collisions between the gantry head and the patient or table assembly are difficult to detect in most treatment planning systems. We have developed and implemented a novel software package for the representation of potential gantry collisions with the couch assembly at the time of treatment planning. Methods: Physical dimensions of the Varian Edge linear accelerator treatment head were measured and reproduced using the Visual Python display package. A script was developed for the Pinnacle treatment planning system to generate a file with the relevant couch, gantry, and isocenter positions for each beam in a planning trial. A python program was developed to parse the information from the TPS and produce a representative model of the couch/gantry system. Using the model and the Visual Python libraries, a rendering window is generated for each beam that allows the planner to evaluate the possibility of a collision. Results: Comparison against heuristic methods and direct verification on the machine validated the collision model generated by the software. Encounters of <1 cm between the gantry treatment head and table were visualized as collisions in our virtual model. Visual windows were created depicting the angle of collision for each beam, including the anticipated table coordinates. Visual rendering of a 6 arc trial with multiple couch positions was completed in under 1 minute, with network bandwidth being the primary bottleneck. Conclusion: The developed software allows for quick examination of possible collisions during the treatment planning process and helps to prevent major collisions prior to plan approval. The software can easily be implemented on future planning systems due to the versatility and platform independence of the Python programming language. Further integration of the software with the treatment planning system will allow the possibility of patient-gantry collision detection for a range of treatment machines.

60 APPLIED LIFE SCIENCES↗

SMS Software Training Exercise 101: SMS and Janam XP20 Data Entry with PSU Collectors

The LANL Sample Management System (SMS) is a software system written in JAVA that supports record keeping associated with handling of media and samples in the BioWatch program. During this portion of the class the instructor will provide: 1. A general overview of what SMS is, 2. How SMS may be configured, 3. How to launch and log-in to SMS, 4. How to accomplish data entry, 5. How to use the Tracking / Exposure History features, 6. How to use the Tracking / Data View and Edit data view features (a. Specifically cover editing a PSU Collector name).

99 GENERAL AND MISCELLANEOUS↗

MyEMSL MTS File Cache Manager

MTS manager for retrieving files from MyEMSL; The MyEMSL MTS File Cache Manager is a part of PRISM, the Proteomics Research Information and Management System. The software processes the MyEMSL Download Queue in the Mass and Time Tag System (MTS) to download files required for processing.

Monroe, Matthew↗

Temperature Measurements in the Magnetic Measurement Facility

Several key LCLS undulator parameter values depend strongly on temperature primarily because of the permanent magnet material the undulators are constructed with. The undulators will be tuned to have specific parameter values in the Magnetic Measurement Facility (MMF). Consequently, it is necessary for the temperature of the MMF to remain fairly constant. Requirements on undulator temperature have been established. When in use, the undulator temperature will be in the range 20.0 {+-} 0.2 C. In the MMF, the undulator tuning will be done at 20.0 {+-} 0.1 C. For special studies, the MMF temperature set point can be changed to a value between 18 C and 23 C with stability of {+-}0.1 C. In order to ensure that the MMF temperature requirements are met, the MMF must have a system to measure temperatures. The accuracy of the MMF temperature measurement system must be better than the {+-}0.1 C undulator tuning temperature tolerance, and is taken to be {+-}0.01 C. The temperature measurement system for the MMF is under construction. It is similar to a prototype system we built two years ago in the Sector 10 alignment lab at SLAC. At that time, our goal was to measure the lab temperature to {+-}0.1 C. The system has worked well for two years and has maintained its accuracy. For the MMF system, we propose better sensors and a more extensive calibration program to achieve the factor of 10 increase in accuracy. In this note we describe the measurement system under construction. We motivate our choice of system components and give an overview of the system. Most of the software for the system has been written and will be discussed. We discuss error sources in temperature measurements and show how these errors have been dealt with. The calibration system is described in detail. All the LCLS undulators must be tuned in the Magnetic Measurement Facility at the same temperature to within {+-}0.1 C. In order to ensure this, we are building a system to measure the temperature of the undulators to {+-}0.01 C. This note describes the temperature measurement system under construction.

43 PARTICLE ACCELERATORS↗

VOLTTRON-enabled Home Energy Management System

Home Energy Management Systems (HEMS) consist of software and hardware systems that provide communication, control, and management among different electronic devices, such as heating, ventilation, and air-conditioning (HVAC) systems. HEMS are a growing market sector in the era of smart grids and smart homes. HEMS can help both homeowners and utilities save money and energy by monitoring and controlling smart devices in a house. Based on the Department of Energy (DOE) Building Energy Data Book, 41% of the energy consumed in the United States is used by buildings (see Figure 1). This shows the importance of saving energy in the building sector. This report introduces two approaches that existing HEMS vendors can use to leverage VOLTTRON as their control and interoperability engine. The goal of this project is to make open-source, user-friendly HEMS available to the market so that everyone can benefit from them. The HEMS introduced as a result of this study should satisfy HEMS specifications such as device monitoring and control, seamless communication between devices, DR, intelligence, data management, and security.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement, Modeling, and Analysis of a Large-scale Blog Sever Workload

Despite the growing popularity of Online Social Networks (OSNs), the workload characteristics of OSN servers, such as those hosting blog services, are not well understood. Understanding workload characteristics is important for opti- mizing and improving the performance of current systems and software based on observed trends. Thus, in this paper, we characterize the system workload of the largest blog hosting servers in South Korea, Tistory1. In addition to understanding the system workload of the blog hosting server, we have developed synthesized workloads and obtained the following major findings: (i) the transfer size of non-multimedia files and blog articles can be modeled by a truncated Pareto distribution and a log-normal distribution respectively, and (ii) users accesses to blog articles do not show temporal locality, but they are strongly biased toward those posted along with images or audio.

99 GENERAL AND MISCELLANEOUS↗

WE-D-9A-06: Open Source Monitor Calibration and Quality Control Software for Enterprise Display Management

Purpose: Medical display monitor calibration and quality control present challenges to medical physicists. The purpose of this work is to demonstrate and share experiences with an open source package that allows for both initial monitor setup and routine performance evaluation. Methods: A software package, pacsDisplay, has been developed over the last decade to aid in the calibration of all monitors within the radiology group in our health system. The software is used to calibrate monitors to follow the DICOM Grayscale Standard Display Function (GSDF) via lookup tables installed on the workstation. Additional functionality facilitates periodic evaluations of both primary and secondary medical monitors to ensure satisfactory performance. This software is installed on all radiology workstations, and can also be run as a stand-alone tool from a USB disk. Recently, a database has been developed to store and centralize the monitor performance data and to provide long-term trends for compliance with internal standards and various accrediting organizations. Results: Implementation and utilization of pacsDisplay has resulted in improved monitor performance across the health system. Monitor testing is now performed at regular intervals and the software is being used across multiple imaging modalities. Monitor performance characteristics such as maximum and minimum luminance, ambient luminance and illuminance, color tracking, and GSDF conformity are loaded into a centralized database for system performance comparisons. Compliance reports for organizations such as MQSA, ACR, and TJC are generated automatically and stored in the same database. Conclusion: An open source software solution has simplified and improved the standardization of displays within our health system. This work serves as an example method for calibrating and testing monitors within an enterprise health system.

60 APPLIED LIFE SCIENCES↗

10 CFR 830 Major Modification Determination for Advanced Test Reactor RDAS and LPCIS Replacement

The replacement of the ATR Control Complex's obsolete computer based Reactor Data Acquisition System (RDAS) and its safety-related Lobe Power Calculation and Indication System (LPCIS) software application is vitally important to ensure the ATR remains available to support this national mission. The RDAS supports safe operation of the reactor by providing 'real-time' plant status information (indications and alarms) for use by the reactor operators via the Console Display System (CDS). The RDAS is a computer support system that acquires analog and digital information from various reactor and reactor support systems. The RDAS information is used to display quadrant and lobe powers via a display interface more user friendly than that provided by the recorders and the Control Room upright panels. RDAS provides input to the Nuclear Engineering ATR Surveillance Data System (ASUDAS) for fuel burn-up analysis and the production of cycle data for experiment sponsors and the generation of the Core Safety Assurance Package (CSAP). RDAS also archives and provides for retrieval of historical plant data which may be used for event reconstruction, data analysis, training and safety analysis. The RDAS, LPCIS and ASUDAS need to be replaced with state-of-the-art technology in order to eliminate problems of aged computer systems, and difficulty in obtaining software upgrades, spare parts, and technical support. The major modification criteria evaluation of the project design did not lead to the conclusion that the project is a major modification. The negative major modification determination is driven by the fact that the project requires a one-for-one equivalent replacement of existing systems that protects and maintains functional and operational requirements as credited in the safety basis.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Frequency Responsive Demand in U.S. Western Power System Model

Frequency control from the demand side presents a novel and viable way to complement control by traditional generators. This paper presents simulation tests of a previously developed load controller in a large interconnected system model. The controller was implemented as a user defined model in PowerWorld software. WECC system model was used. The simulation tests include comparison of situation with and without control, sensitivities to controller location, control gain parameters, and type of end-use loads. The performance is measured in terms of frequency and intertie power flow deviations after a large generator outage.

Power system dynamics, power system control↗