Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “signal processing algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Spectral encoding method for measuring the relative arrival time between x-ray/optical pulses

The advent of few femtosecond x-ray light sources brings promise of x-ray/optical pump-probe experiments that can measure chemical and structural changes in the 10–100 fs time regime. Widely distributed timing systems used at x-ray Free-Electron Laser facilities are typically limited to above 50 fs fwhm jitter in active x-ray/optical synchronization. The approach of single-shot timing measurements is used to sort results in the event processing stage. This has seen wide use to accommodate the insufficient precision of active stabilization schemes. In this article, we review the current technique for “measure-and-sort” at the Linac Coherent Light Source at the SLAC National Accelerator Laboratory. The relative arrival time between an x-ray pulse and an optical pulse is measured near the experimental interaction region as a spectrally encoded cross-correlation signal. The cross-correlation provides a time-stamp for filter-and-sort algorithms used for real-time sorting. Sub-10 fs rms resolution is common in this technique, placing timing precision at the same scale as the duration of the shortest achievable x-ray pulses.

43 PARTICLE ACCELERATORS↗

Distributed fiber sensing systems for 3D combustion temperature field monitoring in coal-fired boilers using optically generated acoustic waves (Final Report)

In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.

47 OTHER INSTRUMENTATION↗

Second Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed. Approximate figure of merit of sensitivity to flow rate is 100KHz/GPM. In addition, we have identified an existing liquid sodium experimental setup for demonstration of flow sensing in environment similar to that of an advanced reactor. The setup consists of a cylindrical vessel and center feed line, where transducer inserted through the lid will measure velocity of the impinging liquid jet. As a calibration experiment, we have assembled a water vessel with center feed with the same dimensions as those of the liquid sodium setup. We have also developed and insertion probe consisting of a 50cm brass waveguide enclosed in protective SS316 tube. Using the water loop, we have demonstrated feasibility of sensing the impinging liquid jet in the vessel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Microfabricated Ion Traps on Sapphire for Larger Trap Areas and Higher Qubit Count

Surface ion traps are a promising platform for quantum computing due to their potential to store large numbers of ions that can be addressed by electrical and optical control signals in order to implement quantum algorithms. Increasing the power of the quantum computer requires increasing the number of ions, but this poses a significant challenge in that it leads to a non-linear increase in on-chip power dissipation. The primary contributor to this power scaling in current devices is the capacitance between the radio frequency (RF) electrode and the metal plane that shields the silicon substrate from the RF signals applied to it. Silicon has traditionally been chosen for the substrate material for compatibility with the processing required for multi-metal-level traps. In this work, we address these capacitance and fabrication challenges by replacing the commonly used silicon substrate with an insulating sapphire substrate to fabricate a multi-metal-level ion trap, while still employing common semiconductor manufacturing techniques. This change in substrate allows the design to remove the metal shielding from the device design, reducing the capacitance of the RF electrode. The electrical characteristics of these traps were measured, specifically trap impedance, capacitance, and voltage breakdown, and compared to nearly identical silicon trap devices. Finally, we used laser cutting techniques to shape a sapphire wafer into bowtie shapes matching silicon traps previously fabricated at Sandia National Labs to explore solutions for integrating sapphire substrates into non-rectangular ion trap designs.

97 MATHEMATICS AND COMPUTING↗

International Spine Radiosurgery Consortium Consensus Guidelines for Target Volume Definition in Spinal Stereotactic Radiosurgery

Purpose: Spinal stereotactic radiosurgery (SRS) is increasingly used to manage spinal metastases. However, target volume definition varies considerably and no consensus target volume guidelines exist. This study proposes consensus target volume definitions using common scenarios in metastatic spine radiosurgery. Methods and Materials: Seven radiation oncologists and 3 neurological surgeons with spinal radiosurgery expertise independently contoured target and critical normal structures for 10 cases representing common scenarios in metastatic spine radiosurgery. Each set of volumes was imported into the Computational Environment for Radiotherapy Research. Quantitative analysis was performed using an expectation maximization algorithm for Simultaneous Truth and Performance Level Estimation (STAPLE) with kappa statistics calculating agreement between physicians. Optimized confidence level consensus contours were identified using histogram agreement analysis and characterized to create target volume definition guidelines. Results: Mean STAPLE agreement sensitivity and specificity was 0.76 (range, 0.67-0.84) and 0.97 (range, 0.94-0.99), respectively, for gross tumor volume (GTV) and 0.79 (range, 0.66-0.91) and 0.96 (range, 0.92-0.98), respectively, for clinical target volume (CTV). Mean kappa agreement was 0.65 (range, 0.54-0.79) for GTV and 0.64 (range, 0.54-0.82) for CTV (P<.01 for GTV and CTV in all cases). STAPLE histogram agreement analysis identified optimal consensus contours (80% confidence limit). Consensus recommendations include that the CTV should include abnormal marrow signal suspicious for microscopic invasion and an adjacent normal bony expansion to account for subclinical tumor spread in the marrow space. No epidural CTV expansion is recommended without epidural disease, and circumferential CTVs encircling the cord should be used only when the vertebral body, bilateral pedicles/lamina, and spinous process are all involved or there is extensive metastatic disease along the circumference of the epidural space. Conclusions: This report provides consensus guidelines for target volume definition for spinal metastases receiving upfront SRS in common clinical situations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE CONTRIBUTION OF THE KINEMATIC SUNYAEV-ZEL'DOVICH EFFECT FROM THE WARM-HOT INTERGALACTIC MEDIUM TO THE FIVE-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE DATA

We study the contribution of the kinematic Sunyaev-Zel'dovich (kSZ) effect, generated by the warm-hot intergalactic medium, to the cosmic microwave background temperature anisotropies in the five-year Wilkinson Microwave Anisotropy Probe (WMAP) data. We explore the concordance {lambda}CDM cosmological model, with and without this kSZ contribution, using a Markov chain Monte Carlo algorithm. Our model requires a single extra parameter to describe this new component. Our results show that the inclusion of the kSZ signal improves the fit to the data without significantly altering the best-fit cosmological parameters except {omega}{sub b} h {sup 2}. The improvement is localized at the l {approx}> 500 multipoles. For the best-fit model, this extra component peaks at l {approx} 450 with an amplitude of 129 {mu}K{sup 2}, and represents 3.1% of the total power measured by WMAP. Nevertheless, at the 2{sigma} level a null kSZ contribution is still compatible with the data. Part of the detected signal could arise from unmasked point sources and/or Poissonianly distributed foreground residuals. A statistically more significant detection requires the wider frequency coverage and angular resolution of the forthcoming Planck mission.

99 GENERAL AND MISCELLANEOUS↗

Iterative Bragg peak removal on X-ray absorption spectra with automatic intensity correction

This study introduces a novel iterative Bragg peak removal with automatic intensity correction (IBR-AIC) methodology for X-ray absorption spectroscopy (XAS), specifically addressing the challenge of Bragg peak interference in the analysis of crystalline materials. The approach integrates experimental adjustments and sophisticated post-processing, including an iterative algorithm for robust calculation of the scaling factor of the absorption coefficients and efficient elimination of the Bragg peaks, a common obstacle in accurately interpreting XAS data, particularly in crystalline samples. The method was thoroughly evaluated on dilute catalysts and thin films, with fluorescence mode and large-angle rotation. The results underscore the technique's effectiveness, adaptability and substantial potential in improving the precision of XAS data analysis. While demonstrating significant promise, the method does have limitations related to signal-to-noise ratio sensitivity and the necessity for meticulous angle selection during experimentation. Overall, IBR-AIC represents a significant advancement in XAS, offering a pragmatic solution to Bragg peak contamination challenges, thereby expanding the applications of XAS in understanding complex materials under diverse experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reconstructions from randomly generated longitudinal electron bunch profiles with Gaussian envelopes using the Gerchberg–Saxton algorithm

Knowledge of longitudinal electron bunch profiles is vital to optimize the performance of plasma wakefield accelerators and x-ray free electron laser linacs. Because of their importance to these novel applications, noninvasive frequency domain techniques are often employed to reconstruct longitudinal bunch profiles from coherent synchrotron, transition, or undulator radiation measurements. In this paper, we detail several common reconstruction techniques involving the Kramers–Kronig phase relationship and Gerchberg–Saxton algorithm. Additionally, through statistical analysis, we draw general conclusions about the accuracy of these reconstruction techniques and the most suitable candidate for reconstructing well-isolated longitudinal bunch profiles from spectroscopic data.

47 OTHER INSTRUMENTATION↗

Wasserstein normalized autoencoder for anomaly detection

A novel anomaly detection algorithm is presented. The Wasserstein normalized autoencoder (WNAE) is a normalized probabilistic model that minimizes the Wasserstein distance between the learned probability distribution—a Boltzmann distribution where the energy is the reconstruction error of the autoencoder (AE)—and the distribution of the training data. This algorithm has been developed and applied to the identification of semivisible jets—conical sprays of visible standard model (SM) particles and invisible dark matter states—with the CMS experiment at the CERN LHC. Trained on jets of particles from simulated SM processes, the WNAE is shown to learn the probability distribution of the input data in a fully unsupervised fashion, such that it effectively identifies new physics jets as anomalies. The model exhibits stable, convergent training and recovers strong classification performance for a wide range of signals against the selected background process, for which a standard AE fails because of outlier reconstruction. In addition, the model improves upon standard normalized autoencoders while remaining fully agnostic to the signal. The WNAE directly tackles the problem of outlier reconstruction, a common failure mode of autoencoders in anomaly detection tasks.

Hayrapetyan, Aram [Yerevan Phys. Inst.]↗

How to COAAD Images. II. A Coaddition Image that is Optimal for Any Purpose in the Background-dominated Noise Limit

Image coaddition is one of the most basic operations that astronomers perform. In Paper I, we presented the optimal ways to coadd images in order to detect faint sources and to perform flux measurements under the assumption that the noise is approximately Gaussian. Here, we build on these results and derive from first principles a coaddition technique that is optimal for any hypothesis testing and measurement (e.g., source detection, flux or shape measurements, and star/galaxy separation), in the background-noise-dominated case. This method has several important properties. The pixels of the resulting coadded image are uncorrelated. This image preserves all the information (from the original individual images) on all spatial frequencies. Any hypothesis testing or measurement that can be done on all the individual images simultaneously, can be done on the coadded image without any loss of information. The PSF of this image is typically as narrow, or narrower than the PSF of the best image in the ensemble. Moreover, this image is practically indistinguishable from a regular single image, meaning that any code that measures any property on a regular astronomical image can be applied to it unchanged. In particular, the optimal source detection statistic derived in Paper I is reproduced by matched filtering this image with its own PSF. This coaddition process, which we call proper coaddition, can be understood as the maximum signal-to-noise ratio measurement of the Fourier transform of the image, weighted in such a way that the noise in the entire Fourier domain is of equal variance. This method has important implications for multi-epoch seeing-limited deep surveys, weak lensing galaxy shape measurements, and diffraction-limited imaging via speckle observations. The last topic will be covered in depth in future papers. We provide an implementation of this algorithm in MATLAB.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast inference of Boosted Decision Trees in FPGAs for particle physics

We describe the implementation of Boosted Decision Trees in the hls4ml library, which allows the translation of a trained model into FPGA firmware through an automated conversion process. Thanks to its fully on-chip implementation, hls4ml performs inference of Boosted Decision Tree models with extremely low latency. With a typical latency less than 100 ns, this solution is suitable for FPGA-based real-time processing, such as in the Level-1 Trigger system of a collider experiment. These developments open up prospects for physicists to deploy BDTs in FPGAs for identifying the origin of jets, better reconstructing the energies of muons, and enabling better selection of rare signal processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessing chromophoric dissolved organic matter (CDOM) distribution, stocks, and fluxes in Apalachicola Bay using combined field, VIIRS ocean color, and model observations

Understanding the role of estuarine-carbon fluxes is essential to improve estimates of the global carbon budget. Dissolved organic matter (DOM) plays an important role in aquatic carbon cycling. Here, the chromophoric fraction of DOM (CDOM) can be readily detected via in situ and remotely-sensed optical measurements. DOM properties, including CDOM absorption coefficient at 412 nm (a g 412) and dissolved organic carbon (DOC) concentrations were examined in Apalachicola Bay, a national estuarine research reserve located in the northeast Gulf of Mexico, using in situ and satellite observations during the spring and fall of 2015. Synoptic and accurate representation of estuarine-scale processes using satellite ocean color imagery necessitates the removal of atmospheric contribu- tion (~90%) to signals received by satellite sensors to successfully link to in situ observations. Three atmospheric correction schemes (e.g., Standard NIR correction, Iterative NIR correction, and SWIR correction) were tested first to find a suitable correction scheme for the VIIRS imagery in low to moderately turbid Apalachicola Bay. The iterative NIR correction performed well, and validation showed high correlation (R 2 = 0.95, N = 25) against in situ light measurements. A VIIRS-based CDOM algorithm was developed (R 2 = 0.87, N = 9) and validated (R 2 = 0.76, N = 20, RMSE = 0.29 m -1 ) against in situ observations. Subsequently, ag412 was used as a proxy of DOC in March (DOC = 1.08 + 0.94 × a g 412,R 2 =0.88, N = 13)and in November (DOC= 1.61 + 1.33 × a g 412, R 2 = 0.83, N = 24) to derive DOC maps that provided synoptic views of DOC distribution, sources, and their transport to the coastal waters during the wet and dry seasons. The estimated DOC stocks were ~3.71 × 10 6 kg C in March and ~4.07 × 10 6 kg C in November over an area of ~560 km2. Volume flux (out of the bay) almost doubled for March 24 (735 m 3 s -1 ) relative to November 4 (378 m 3 s -1 ). However, estimates of DOC fluxes exported out of the bay from model-derived currents and satellite-derived DOC were only marginally greater in March (0.163 × 10 6 kg C d -1 ) than in November (0.124 × 10 6 kg C d -1 ) and reflected greater DOC stocks in the fall. Finally, the combination of satellite-, field-, and model-based observations revealed the strong linkage between the Apalachicola River plume, a major source of DOM, and the overall hydrodynamic forcing that controlled distributions of CDOM abundance, DOC concentration, stocks, and fluxes in the bay.

54 ENVIRONMENTAL SCIENCES↗

Decoupling Mesoscale Functional Response in PLZT across the Ferroelectric–Relaxor Phase Transition with Contact Kelvin Probe Force Microscopy and Machine Learning

Relaxor ferroelectrics exhibit a range of interesting material behavior, including high electromechanical response, polarization rotations, as well as temperature and electric field-driven phase transitions. The origin of this unusual functional behavior remains elusive due to limited knowledge on polarization dynamics at the nanoscale. Piezoresponse force microscopy and associated switching spectroscopy provide access to local electromechanical properties on the micro- and nanoscale, which can help to address some of these gaps in our knowledge. However, these techniques are inherently prone to artefacts caused by signal contributions emanating from electrostatic interactions between tip and sample. Understanding functional behavior of complex, disordered systems like relaxor materials with unknown electromechanical properties therefore requires a technique that allows distinguishing between electromechanical and electrostatic response. Here, contact Kelvin probe force microscopy (cKPFM) is used to gain insight into the evolution of local electromechanical and capacitive properties of a representative relaxor material lead lanthanum zirconate across the phase transition from a ferroelectric to relaxor state. The obtained multidimensional data set was processed using an unsupervised machine learning algorithm to detect variations in functional response across the probed area and temperature range. Further analysis showed the formation of two separate cKPFM response bands below 50 °C, providing evidence for polarization switching. At higher temperatures only one band is observed, indicating an electrostatic origin of the measured response. In addition, the junction potential difference, which was extracted from the cKPFM data, becomes independent of the temperature in the relaxor state. As a result, the combination of this multidimensional voltage spectroscopy technique and machine learning allows to identify the origin of the measured functional response and to decouple ferroelectric from electrostatic phenomena necessary to understand the functional behavior of complex, disordered systems like relaxor materials.

36 MATERIALS SCIENCE↗

Toward artifact-free data in Hadamard transform-based double multiplexing of ion mobility-Orbitrap mass spectrometry

The integration of ion mobility spectrometry (IMS) with trap-based mass spectrometer (MS) such as Orbitrap using the dual gate approach suffers from low duty cycle. Efforts to improve the duty cycle involve the utilization of Hadamard transform based double multiplexing which significantly improve the signal to noise ratio and duty cycle of the ion mobility – Orbitrap mass spectrometry (IM – Orbitrap MS) platform. However, significant fluctuations in ion intensity and the temporal shifts in the encoded data give rise to artifacts and noise in the demultiplexed data which significantly reduce the data quality and negate the benefits of multiplexing. We propose a new approach that identifies the true IM peaks and helps in eliminating the artifacts in the demultiplexed data leading to a decrease in false positives in subsequent data processing. The algorithm takes an analytical approach to first identify the position of the IM peak in the temporal domain, and then demultiplex and identify the true data making it easier for subsequent data processing. After the application of the algorithm, the quality of the IM-Orbitrap MS measurements was greatly improved because of the reduction in artifacts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Statistical Framework for Operational lnfrasound Monitoring [Slides]

Historically, much infrasound research has been event-based, with known events providing the ground-truth required to inform the search for associated signals. For monitoring nuclear explosions in the atmosphere or underground, reliable techniques are required for operational infrasound data processing that effectively minimize both false alarms and missed detections. A difficulty in working with infrasound data is to adequately account for dynamic variations in the atmosphere, which occur over a variety of temporal and spatial scales. However, contrary to one's intuition, it is not necessary to have a high fidelity atmospheric model in order to perform robust detection, association and location. We present detection, association and location algorithms that assume no a priori knowledge of the atmosphere; however, where knowledge is available we show how it can be used to reduce the associated uncertainties. Rather than exporting seismic techniques to the problem of infrasound monitoring, our techniques were developed from the ground-up to properly account for the unique considerations of atmospheric acoustics. In contrast with other routinely used infrasound detectors, we utilize a contextual detection hypothesis that adaptively accounts for temporally variable correlated ambient noise. Our location scheme allows for the location of infrasound events without any meteorological data through a Bayesian framework. We demonstrate the application of the techniques presented here for a series of ground-truth events, and for routine data processing of large amounts of regional infrasound data.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Coordinated Regulation of Virulence during Systemic Infection of Salmonella enterica serovar Typhimurium

Salmonella must respond to a myriad of environmental cues during infection of a mouse and express specific subsets of genes in a temporal and spatial manner to subvert the host defense mechanisms but these regulatory pathways are poorly established. To unravel how micro-environmental signals are processed and integrated into coordinated action, we constructed in-frame non-polar deletions of 84 regulators inferred to play a role in Salmonella typhimurium virulence and tested them in three virulence assays (intraperitoneal (i.p.), and intragastric (i.g.) infection in BALB/c mice, and persistence in SvJ129 mice). Overall 36 regulators were identified that were less virulent in at least one assay, and of those, 15 regulators were required for systemic mouse infection in an acute infection model. As a first step towards understanding the interplay between a pathogen and its host from a systems biology standpoint we focused on these 15 genes. Transcriptional profiles were obtained for each of these 15 regulators from strains grown under four different environmental conditions. These results as well as publicly available transcriptional profiles were analyzed using both network inference and cluster analysis algorithms. The analysis predicts a regulatory network in which all 15 regulators control a specific set of genes necessary for Salmonella to cause systemic infection. We tested the regulatory model by expressing a subset of the regulators in trans and monitoring transcription of 7 known virulence factors located within Salmonella pathogenicity island 2 (SPI-2). These experiments validated the regulatory model and showed that, for these 7 genes, the response regulator SsrB and the marR type regulator SlyA co-regulate in a regulatory cascade by integrating multiple signals.

59 BASIC BIOLOGICAL SCIENCES↗

Event driven readout architecture with non-priority arbitration for radiation detectors

A novel event driven readout architecture, EDWARD (Event Driven with Access and 8 Reset Decoder) architecture, for highly granular pixel detectors is presented. It incorporates, inter alia, an asynchronous arbitration tree based on Seitz' arbiters, removing the need for an imposed prioritization scheme. It also provides protection against glitches during readout. The system allows not only reading pixel activities, but also retrieving additional data, both analog and digital, from the pixels. A novel in-channel logic allows the entire readout process to be split into consecutive phases for additional flexibility. All operations are controlled by only one edge of the clock signal, seen as an acknowledge token, so there is no dead time between readouts.

47 OTHER INSTRUMENTATION↗

Cycle-by-cycle Delay Estimation at Signalized Intersections by using Machine Learning and Simulated Video Detection Data

Accurate estimation of delay is crucial for efficient traffic signal operations. Estimation of delay in the real-time manner using traditional loop detectors requires advanced detectors (in addition to stop-bar detection). In cases when this detection layout is not in place, delay estimates are approximated with a lower accuracy. Video detection is one of the most frequently deployed detection systems at signalized intersections in recent years. In most cases video detection operates in the same way as traditional inductive loops. However, when coupled with computer vision algorithms, video detection systems could be used to retrieve additional information (e.g., vehicular arrivals and departures) that cannot be taken out from the conventional systems (e.g., long stop-bar loop detectors). Although present for several decades, video detection data were not frequently examined for delay estimation purposes. In this study, we proposed a novel delay estimation model which can be developed with only data from stop-bar video detectors. Relevant data were collected from a simulation model of 11 signalized intersections at downtown Chattanooga, TN and processed to create needed inputs for model development. With the use of multigene genetic programming the authors developed a delay model that outperforms accuracy of multi regression model. Furthermore, authors evaluated the developed model by comparison with the other benchmark delay models, such as HCM and approach delay model. It was found that the developed MGGP delay model outperforms benchmark models for a wide range of traffic and signal operation conditions.

Erdagi, Ismet Goksad↗