Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Optical-pump–terahertz-probe spectroscopy in high magnetic fields with kHz single-shot detection

We demonstrate optical pump–THz probe (OPTP) spectroscopy with a variable external magnetic field (0–9 T), in which the time-dependent THz signal is measured by echelon-based single-shot detection at a repetition rate of 1 kHz. The method reduces data acquisition times by more than an order of magnitude compared to conventional electro-optic sampling using a scanning delay stage. The approach illustrates the wide applicability of the single-shot measurement approach to non-equilibrium systems that are studied through OPTP spectroscopy, especially in cases where parameters such as magnetic field strength (B) or other experimental parameters are varied. We demonstrate the capabilities of our measurement by performing cyclotron resonance experiments in bulk silicon, where we observe B-field-dependent carrier relaxation and distinct relaxation rates for different carrier types. We use a pair of economical linear array detectors to measure 500 time points on each shot, offering an equivalent performance to camera-based detection with possibilities for higher repetition rates.

Instruments & Instrumentation↗

Development of an MEMS ultrasonic microphone array system and its application to compressed wavefield imaging of concrete

Abstract Although contactless ultrasonic wavefield imaging shows potential for effective nondestructive inspection of various engineering materials, it has been rarely applied to concrete materials owing to technical challenges including low signal-to-noise ratio (SNR) caused by inherent heterogeneity of concrete. This paper presents development of a multi-channel MEMS ultrasonic microphone array system and its application to compressed wavefield imaging of concrete materials. The developed multi-channel MEMS ultrasonic microphone array system contains eight MEMS ultrasonic microphone elements and a signal conditioning circuit that enables measurements of ultrasonic signals with high SNR. A compressed sensing approach, based on the multiple measurement vector (MMV) concept, is applied to reconstruct a full dense ultrasonic wavefield data from sparsely sampled ultrasonic wavefield data. Experiments are carried out on a laboratory concrete sample to verify the performance of the developed MEMS microphone array system and proposed compressed sensing approach and then large-scale concrete samples to demonstrate practical application. The experimental results demonstrate that the developed MEMS microphone array system provides high-quality (SNR > 20 dB) ultrasonic data collected from concrete elements; furthermore, the proposed compressed sensing approach provides accurate reconstruction of dense wavefield data, as determined by peak signal-to-noise ratio (PSNR), from sparsely measured wavefield data with compression ratios up to 85% and PSNR above 25 dB in data collected form realistic large-scale concrete samples. By combining the MEMS array system and compressed sensing approach, the total ultrasonic data acquisition time needed to produce dense wavefield data can be significantly reduced.

Instruments & Instrumentation↗

Frequency correction device uses digital circuitry

Signal acquisition and tracking system covering a wide range of frequencies uses a digital circuit to sample the frequency of an incoming signal and provide correction pulses to the voltage-controlled oscillator. The circuit can also sense the presence of a signal on any one of the input lines.

Schaefer, D.↗

Self-calibrating threshold detector

A self calibrating threshold detector comprises a single demodulating channel which includes a mixer having one input receiving the incoming signal and another input receiving a local replica code. During a short time interval, an incorrect local code is applied to the mixer to incorrectly demodulate the incoming signal and to provide a reference level that calibrates the noise propagating through the channel. A sample and hold circuit is coupled to the channel for storing a sample of the reference level. During a relatively long time interval, the correct replica code provides an output level which ranges between the reference level and a maximum level that represents incoming signal presence and synchronism with the replica code. A summer substracts the stored sample reference from the output level to provide a resultant difference signal indicative of the acquisition of the expected signal.

Barnes, J. R.↗

Evaluation of concepts and methods for extraction of flow parameters from laser transit anemometry data

A Monte-Carlo type simulation system was developed to test concepts and associated algorithms proposed by Mayo and Smart (1984) for the extraction of two-dimensional flow parameters from laser transit anemometry data sets. The Monte-Carlo LTA simulation program models a flow field as well as the sample volume geometry of the LTA system, thereby permitting simulation of two-dimensional data acquisition in a three-dimensional flow field. The results of these tests on the proposed processing concepts suggest that the instrument is capable of measuring mean velocities to less than +0.15 percent error and flow angles to less then +0.3 percent for turbulence intensities of up to 15.0 percent.

Humphreys, W. M., Jr.↗

Ejecta patterns of Meteor Crater, Arizona derived from the linear un-mixing of TIMS data and laboratory thermal emission spectra

Accurate interpretation of thermal infrared data depends upon the understanding and removal of complicating effects. These effects may include physical mixing of various mineralogies and particle sizes, atmospheric absorption and emission, surficial coatings, geometry effects, and differential surface temperatures. The focus is the examination of the linear spectral mixing of individual mineral or endmember spectra. Linear addition of spectra, for particles larger than the wavelength, allows for a straight-forward method of deconvolving the observed spectra, predicting a volume percent of each endmember. The 'forward analysis' of linear mixing (comparing the spectra of physical mixtures to numerical mixtures) has received much attention. The reverse approach of un-mixing thermal emission spectra was examined with remotely sensed data, but no laboratory verification exists. Understanding of the effects of spectral mixing on high resolution laboratory spectra allows for the extrapolation to lower resolution, and often more complicated, remotely gathered data. Thermal Infrared Multispectral Scanner (TIMS) data for Meteor Crater, Arizona were acquired in Sep. 1987. The spectral un-mixing of these data gives a unique test of the laboratory results. Meteor Crater (1.2 km in diameter and 180 m deep) is located in north-central Arizona, west of Canyon Diablo. The arid environment, paucity of vegetation, and low relief make the region ideal for remote data acquisition. Within the horizontal sedimentary sequence that forms the upper Colorado Plateau, the oldest unit sampled by the impact crater was the Permian Coconino Sandstone. A thin bed of the Toroweap Formation, also of Permian age, conformably overlays the Coconino. Above the Toroweap lies the Permian Kiabab Limestone which, in turn, is covered by a thin veneer of the Moenkopi Formation. The Moenkopi is Triassic in age and has two distinct sub-units in the vicinity of the crater. The lower Wupatki member is a fine-grained sandstone, while the upper Moqui member is a fissile siltstone. Ejecta from these units are preserved as inverted stratigraphy up to 2 crater radii from the rim. The mineralogical contrast between the units, relative lack of post-emplacement erosion and ejecta mixing provide a unique site to apply the un-mixing model. Selection of the aforementioned units as endmembers reveals distinct patterns in the ejecta of the crater.

Ramsey, Michael S.↗

High-Resolution Imaged-Based 3D Reconstruction Combined with X-Ray CT Data Enables Comprehensive Non-Destructive Documentation and Targeted Research of Astromaterials

Providing web-based data of complex and sensitive astromaterials (including meteorites and lunar samples) in novel formats enhances existing preliminary examination data on these samples and supports targeted sample requests and analyses. We have developed and tested a rigorous protocol for collecting highly detailed imagery of meteorites and complex lunar samples in non-contaminating environments. These data are reduced to create interactive 3D models of the samples. We intend to provide these data as they are acquired on NASA's Astromaterials Acquisition and Curation website at http://curator.jsc.nasa.gov/.

Blumenfeld, E. H.↗

Accuracy and precision of ESI-Orbitrap-IRMS observations of hours to tens of hours via reservoir injection

Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.

58 GEOSCIENCES↗

Autonomous support for microorganism research in space

A preliminary design for performing on-orbit, autonomous research on microorganisms and cultured cells/tissues is presented. An understanding of gravity and its effects on cells is crucial for space exploration as well as for terrestrial applications. The payload is designed to be compatible with the COMmercial Experiment Transported (COMET) launch vehicle, an orbiter middeck locker interface, and with Space Station Freedom. Uplink/downlink capabilities and sample return through controlled reentry are available for all carriers. Autonomous testing activities are preprogrammed with inflight reprogrammability. Sensors for monitoring temperature, pH, light, gravity levels, vibration, and radiation are provided for environmental regulation and experimental data collection. Additional experiment data acquisition includes optical density measurement, microscopy, video, and file photography. Onboard full data storage capabilities are provided. A fluid transfer mechanism is utilized for inoculation, sampling, and nutrient replenishment of experiment cultures. In addition to payload design, representative experiments were developed to ensure scientific objectives remained compatible with hardware capabilities. The project is defined to provide biological data pertinent to extended duration crewed space flight including crew health issues and development of a Controlled Ecological Life Support System (CELSS). In addition, opportunities are opened for investigations leading to commercial applications of space, such as pharmaceutical development, modeling of terrestrial diseases, and material processing.

Luttges, M. W.↗

Long-Term Photovoltaic System Performance in Cold, Snowy Climates

As countries around the world transition towards renewable energy, there is increasing interest in using photovoltaic (PV) technologies to help decarbonize northern and alpine communities due to their scalability and affordability. However, a barrier to large-scale adoption of PV in cold climates is long-term performance uncertainty under snowfall, freeze-thaw cycles, low temperatures, and high winds. In this work, we provide a comprehensive review of published silicon degradation rates in cold Koppen-Geiger climate classifications of Dfb (humid continental), Dfc (subarctic), and ET (tundra). We first analyze the system degradation rates of three subarctic ground-mounted photovoltaic sites in North America using the RdTools year-on-year method: an Al-BSF double-axis tracking site in Fairbanks, Alaska (65degrees N); a PERC and silicon heterojunction bifacial vertical and south-tilted site in Fairbanks, Alaska; and a PERC south-facing fixed-tilt site in Fort Simpson, Northwest Territories (62degrees N). Degradation rates of these newly analyzed sites vary between -0.4%/year and -1.5%/year. Combining these data with previously reported cold climate degradation rates, we show that the distribution of cold climate degradation peaks at -0.1%/year to -0.2%/year but has a large tail with rates above -0.5%/year. The average reported cold climate degradation rate is -0.45%/year, whereas the median value is -0.33%/year. These results suggest that despite frequent freeze-thaw cycles and potential exposure to high wind and snow loads, PV systems in cold climates tend to degrade slower than PV systems in warmer climates. The limited sample size of reported degradation rates in cold climates (27) motivates the need for further data acquisition and monitoring efforts as new technologies are deployed.

14 SOLAR ENERGY↗

Two-dimensional heteronuclear single quantum coherence (HSQC) NMR spectra of lignin isolated from Populus trichocarpa residues after CELF pretreatment and CBP fermentation

Here we present a curated dataset of a series of two-dimensional heteronuclear single quantum coherence (HSQC) nuclear magnetic resonance (NMR) spectra of lignin isolated from a woody energy crop (Populus trichocarpa) residues after co-solvent enhanced lignocellulosic fractionation (CELF) pretreatment and consolidated bioprocessing (CBP) process. The natural poplar variant GW-9947 from the Center for Bioenergy Innovation (CBI) was used. The poplar was knife milled and passed through a 1 mm sieve. The CELF pretreatment was performed in a Parr autoclave reactor with 7.5 wt % solids loading, 0.5 wt% H2SO4 as catalyst at 150°C with 15, 25 and 30 minutes, respectively. Tetrahydrofuran was added in a 1:1 mass ratio with water as the pretreatment solvent. The residues from CELF pretreatment were then subjected to CBP using the bacterium C. thermocellum DSM 1313. CBP fermentations were performed at 60 °C in a shaker at 50 grams/L solids loadings. Lignin was isolated from the pretreated samples after ball-milling in a porcelain jar with ceramic balls via Retsch PM 200 at 580 rpm for 2.5 h followed by enzymatic hydrolysis in acetate buffer (pH 4.8, 50 °C) for 48 h. The lignin samples were characterized using 13C–1H HSQC experiments which were performed in a Bruker Avance III HD 500 MHz NMR spectrometer operating at a frequency of 125.12 MHz for the 13C nucleus. A standard Bruker pulse sequence was used on a Prodigy platform cryoprobe. The dry lignin samples were dissolved in deuterated dimethylsulfoxide for HSQC experiments. The spectra were acquired under the following acquisition conditions: 210 ppm spectral width in F1 (13C) dimension with 256 data points and 11 ppm spectral width in F2 (1H) dimension with 1024 data points, a 90° pulse, a one bond C–H coupling constant of 145 Hz, a 1.0 s pulse delay, and 64 scans. All the data was processed using the TopSpin 3.6 software (Bruker BioSpin). The NMR spectra provides structural characteristics information about lignin remaining in solids after CELF (150 °C with 15, 25 and 30 minutes) process and C. thermocellum CBP.

Lignin structure, HSQC, poplar, CELF, CBP, CBI↗

Mechanism Across Scales: A Holistic Modeling Framework Integrating Laboratory and Field Studies for Microbial Ecology

Over the last century, leaps in technology for imaging, sampling, detection, high-throughput sequencing, and -omics analyses have revolutionized microbial ecology to enable rapid acquisition of extensive datasets for microbial communities across the ever-increasing temporal and spatial scales. The present challenge is capitalizing on our enhanced abilities of observation and integrating diverse data types from different scales, resolutions, and disciplines to reach a causal and mechanistic understanding of how microbial communities transform and respond to perturbations in the environment. This type of causal and mechanistic understanding will make predictions of microbial community behavior more robust and actionable in addressing microbially mediated global problems. To discern drivers of microbial community assembly and function, we recognize the need for a conceptual, quantitative framework that connects measurements of genomic potential, the environment, and ecological and physical forces to rates of microbial growth at specific locations. We describe the Framework for Integrated, Conceptual, and Systematic Microbial Ecology (FICSME), an experimental design framework for conducting process-focused microbial ecology studies that incorporates biological, chemical, and physical drivers of a microbial system into a conceptual model. Through iterative cycles that advance our understanding of the coupling across scales and processes, we can reliably predict how perturbations to microbial systems impact ecosystem-scale processes or vice versa. We describe an approach and potential applications for using the FICSME to elucidate the mechanisms of globally important ecological and physical processes, toward attaining the goal of predicting the structure and function of microbial communities in chemically complex natural environments.

59 BASIC BIOLOGICAL SCIENCES↗

Electromagnetic measurement of lightning strikes to aircraft

Recent in-flight direct-strike lightning research, using an NASA F-1068 aircraft, is reviewed. The instrumentation system which records the rates of change of electric and magnetic flow density at several locations on the aircraft and rate of change of strike current to the boom is described. The measurement parameters are: rate of change of electric flux density over a range of 50 amperes per square meter, rate of change of magnetic flux density over a range of 20,000 tesla per second, and rate of change of strike current over a range of 100 kilo-amperes per microsecond. The isolated and shielded instrumentation system employs high-sample-rate digital transient recorders with augmented memory capacity and a wideband analog recorder for data acquisition and recording. The data obtained during the 1980 flight test program are presented and the data significance is discussed.

Pitts, F. L.↗

Computer controlled facility for measurement of the bidirectional scattering distribution function

A computer controlled facility for measurement of the bidirectional scattering distribution function is described, with application to the evaluation of spacecraft surface contamination in optical and thermal control systems. An automatic detector/sampleholder allows a 360-deg detector scan around the sample for a complete bidirectional reflectance and transmittance distribution function characterization. The system demonstrates reduced data acquisition and reduction cycle time, and improved accuracy.

Carosso, Paolo A.↗

Measurement of surface microtopography

Acquisition of ground truth data for use in microwave interaction modeling requires measurement of surface roughness sampled at intervals comparable to a fraction of the microwave wavelength and extensive enough to adequately represent the statistics of a surface unit. Sub-centimetric measurement accuracy is thus required over large areas, and existing techniques are usually inadequate. A technique is discussed for acquiring the necessary photogrammetric data using twin film cameras mounted on a helicopter. In an attempt to eliminate tedious data reduction, an automated technique was applied to the helicopter photographs, and results were compared to those produced by conventional stereogrammetry. Derived root-mean-square (RMS) roughness for the same stereo-pair was 7.5 cm for the automated technique versus 6.5 cm for the manual method. The principal source of error is probably due to vegetation in the scene, which affects the automated technique but is ignored by a human operator.

Wall, S. D.↗

A three-dimensional orthogonal laser velocimeter for the NASA Ames 7- by 10-foot wind tunnel

A three-component dual-beam laser-velocimeter system has been designed, fabricated, and implemented in the 7-by 10-Foot Wind Tunnel at NASA Ames Research Center. The instrument utilizes optical access from both sides and the top of the test section, and is configured for uncoupled orthogonal measurements of the three Cartesian coordinates of velocity. Bragg cell optics are used to provide fringe velocity bias. Modular system design provides great flexibility in the location of sending and receiving optics to adapt to specific experimental requirements. Near-focus Schmidt-Cassegrain optic modules may be positioned for collection of forward or backward scattered light over a large solid angle, and may be clustered to further increase collection solid angle. Multimode fiber optics transmit collected light to the photomultiplier tubes for processing. Counters are used to process the photomultiplier signals and transfer the processed data digitally via buffered interface controller to the host MS-DOS computer. Considerable data reduction and graphical display programming permit on-line control of data acquisition and evaluation of the incoming data. This paper describes this system in detail and presents sample data illustrating the system's capability.

Dunagan, Stephen E.↗

Climate and infectious disease: use of remote sensing for detection of Vibrio cholerae by indirect measurement

It has long been known that cholera outbreaks can be initiated when Vibrio cholerae, the bacterium that causes cholera, is present in drinking water in sufficient numbers to constitute an infective dose, if ingested by humans. Outbreaks associated with drinking or bathing in unpurified river or brackish water may directly or indirectly depend on such conditions as water temperature, nutrient concentration, and plankton production that may be favorable for growth and reproduction of the bacterium. Although these environmental parameters have routinely been measured by using water samples collected aboard research ships, the available data sets are sparse and infrequent. Furthermore, shipboard data acquisition is both expensive and time-consuming. Interpolation to regional scales can also be problematic. Although the bacterium, V. cholerae, cannot be sensed directly, remotely sensed data can be used to infer its presence. In the study reported here, satellite data were used to monitor the timing and spread of cholera. Public domain remote sensing data for the Bay of Bengal were compared directly with cholera case data collected in Bangladesh from 1992-1995. The remote sensing data included sea surface temperature and sea surface height. It was discovered that sea surface temperature shows an annual cycle similar to the cholera case data. Sea surface height may be an indicator of incursion of plankton-laden water inland, e.g., tidal rivers, because it was also found to be correlated with cholera outbreaks. The extensive studies accomplished during the past 25 years, confirming the hypothesis that V. cholerae is autochthonous to the aquatic environment and is a commensal of zooplankton, i.e., copepods, when combined with the findings of the satellite data analyses, provide strong evidence that cholera epidemics are climate-linked.

Cholera/epidemiology↗

Water Across Synthetic Aperture Radar Data (WASARD): SAR Water Body Classification for the Open Data Cube

The detection of inland water bodies from Synthetic Aperture Radar (SAR) data provides a great advantage over water detection with optical data, since SAR imaging is not impeded by cloud cover. Traditional methods of detecting water from SAR data involves using thresholding methods that can be labor intensive and imprecise. This paper describes Water Across Synthetic Aperture Radar Data (WASARD): a method of water detection from SAR data which automates and simplifies the thresholding process using machine learning on training data created from Geoscience Australia’s WOFS algorithm. Of the machine learning models tested, the Linear Support Vector Machine was determined to be optimal, with the option of training using solely the VH polarization or a combination of the VH and VV polarizations. WASARD was able to identify water in the target area with a correlation of 97% with WOFS. Sentinel-1, Open Data Cube, Earth Observations, Machine Learning, Water Detection 1. INTRODUCTION Water classification is an important function of Earth imaging satellites, as accurate remote classification of land and water can assist in land use analysis, flood prediction, climate change research, as well as a variety of agricultural applications [2]. The ability to identify bodies of water remotely via satellite is immensely cheaper than contracting surveys of the areas in question, meaning that an application that can accurately use satellite data towards this function can make valuable information available to nations which would not be able to afford it otherwise. Highly reliable applications for the remote detection of water currently exist for use with optical satellite data such as that provided by LANDSAT. One such application, Geoscience Australia’s Water Observations from Space (WOFS) has already been ported for use with the Open Data Cube [6]. However, water detection using optical data from Landsat is constrained by its relatively long revisit cycle of 16 days [5], and water detection using any optical data is constrained in that it lacks the ability to make accurate classifications through cloud cover [2]. The alternative solution which solves these problems is water detection using SAR data, which images the Earth using cloud-penetrating microwaves. Because of its advantages over optical data, much research has been done into water detection using SAR data. Traditionally, this has been done using the thresholding method, which involves picking a polarization band and labeling all pixels for which this band’s value is below a certain threshold as containing water. The thresholding method works since water tends to return a much lower backscatter value to the satellite than land [1]. However, this method can be flawed since estimating the proper threshold is often imprecise, complicated, and labor intensive for the end user. Thresholding also tends to use data from only one SAR polarization, when a combination of polarizations can provide insight into whether water is present. [2] In order to alleviate these problems, this paper presents an application for the Open Data Cube to detect water from SAR data using support vector machine (SVM) classification. 2. PLATFORM WASARD is an application for the Open Data Cube, a mechanism which provides a simple yet efficient means of ingesting, storing, and retrieving remote sensing data. Data can be ingested and made analysis ready according to whatever specifications the researcher chooses, and easily resampled to artificially alter a scene’s resolution. Currently WASARD supports water detection on scenes from ESA’s Sentinel-1 and JAXA’s ALOS. When testing WASARD, Sentinel-1 was most commonly used due to its relatively high spatial resolution and its rapid 6 day revisit cycle [5]. With minor alterations to the application's code, however, it could support data from other satellites. 3. METHODOLOGY Using supervised classification, WASARD compares SAR data to a dataset pre-classified by WOFS in order to train an SVM classifier. This classifier is then used to detect water in other SAR scenes outside the training set. Accuracy was measured according to the following metrics:  Precision: a measure of what percentage of the points WASARD labels as water are truly water  Recall: a measure of what percentage of the total water cover WASARD was able to identify.  F1 Score: a harmonic average of the precision and recall scores Both precision and recall are calculated at the end of the training phase, when the trained classifier is compared to a testing dataset. Because the WOFS algorithm’s classifications are used as the truth values when training a WASARD classifier, when precision and recall are mentioned in this paper, they are always with respect to the values produced by WOFS on a similar scene of Landsat data, which themselves have a classification accuracy of 97% [6]. Visual representations of water identified by WASARD in this paper were produced using the function wasard_plot(), which is included in WASARD. 3.1 Algorithm Selection The machine learning model used by WASARD is the Linear Support Vector Machine (SVM). This model uses a supervised learning algorithm to develop a classifier, meaning it creates a vector which can be multiplied by the vector formed by the relevant data bands to determine whether a pixel in a SAR scene contains water. This classifier is trained by comparing data points from selected bands in a SAR scene to their respective labels, which in this case are “water” or “not water” as given by the WOFS algorithm. The SVM was selected over the Random Forest model, which outperformed the SVM in training speed, but had a greater classification time and lower accuracy, and the Multilayer Perceptron Artificial Neural Network, which had a slightly higher average accuracy than the SVM, but much greater training and classification times. Figure 1: Visual representation of the SVM Classifier. Each white point represents a pixel in a SAR scene. In Figure 1, the diagonal line separating pixels determined to be water from those determined not to be water represents the actual classification vector produced by the SVM. It is worth noting that once the model has been trained, classification of pixels is done in a similar manner as in the thresholding method. This is especially true if only one band was used to train the model. 3.1 Feature Selection Sentinel-1 collects data from two bands: the Vertical/Vertical polarization (VV) and the Vertical/Horizontal polarization (VH). When 100 SVM classifiers were created for each polarization individually, and for the combination of the two, the following results were achieved: Figure 2: Accuracy of classifiers trained using different polarization bands. Precision and Recall were measured with respect to the values produced by WOFS. Figure 2 demonstrates that using both the VV and VH bands trades slightly lower recall for significantly greater precision when compared with the VH band alone, and that using the VV band alone is inferior in both metrics. WASARD therefore defaults to using both the VV and VH bands, and includes the option to use solely the VH band. The VV polarization’s lower precision compared to the VH polarization is in contrast to results from previous research and may merit further analysis [4]. 3.2 Training a Classifier The steps in training a classifier with WASARD are 1. Selecting two scenes (one SAR, one optical) with the same spatial extents, and acquired close to each other in time, with a preference that the scenes are taken on the same day. 2. Using the WOFS algorithm to produce an array of the detected water in the scene of optical data, to be used as the labels during supervised learning 3. Data points from the selected bands from the SAR acquisition are bundled together into an array with the corresponding labels gathered from WOFS. A random sample with an equal number of points labeled “Water” and “Not Water” is selected to be partitioned into a training and a testing dataset 4. Using Scikit-Learn’s LinearSVC object, the training dataset is used to produce a classifier, which is then tested against the testing dataset to determine its precision and recall The result is a wasard_classifier object, which has the following attributes: 1. f1, recall, and precision: 3 metrics used to determine the classifier’s accuracy 2. Coefficient: Vector which the SVM uses to make its predictions. The classifier detects water when the dot product of the coefficient and the vector formed by the SAR bands is positive 3. Save(): allows a user to save a classifier to the disk in order to use it without retraining 4. wasard_classify(): Classifies an entire xarray of SAR data using the SVM classifier All of the above steps are performed automatically when the user creates a wasard_classifier object. 3.3 Classifying a Dataset Once the classifier has been created, it can be used to detect water in an xarray of SAR data using wasard_classify(). By taking the dot product of the classifier’s coefficients and the vector formed by the selected bands of SAR data, an array of predictions is constructed. A classifier can effectively be used on the same spatial extents as the ones where it was trained, or on any area with a similar landscape. While

Kreiser, Zachary↗