Enhanced pool boiling heat transfer using novel inverted trapezoid microgroove structures

Pool boiling heat transfer improvements with enhanced surfaces have been extensively studied for various hydrofluorocarbon (HFC) refrigerants. However, there is a limited number of studies in the open literature that focus on the pool boiling heat transfer characteristics of hydrofluoroolefin (HFO) refrigerants on enhanced surfaces. This study aims to address this gap by analyzing the pool boiling behavior of HFO refrigerants, specifically R1234yf and R1234ze(E). Experiments were conducted on both plain surfaces and novel inverted trapezoid microgroove structures. Further, the experimental results indicate that the microgroove structures can improve heat transfer coefficients by up to 80% compared to plain surfaces. Additionally, the performance of R1234yf and R1234ze(E) was compared to that of R134. It was observed that R1234yf exhibited comparable performance to R134a, while R1234ze(E) showed slightly lower performance. To assess the influence of saturation temperature on pool boiling heat transfer, tests were conducted at different saturation temperatures of 15℃, 25℃, and 35℃. The findings revealed that the pool boiling heat transfer coefficient increases with rising saturation temperature.

42 ENGINEERING↗

Highly-Efficient Microemulsion-Based Absorption Chillers for HVAC Application

Air conditioning is a necessity to achieve a comfortable, habitable home or office for many places in US. However, vapor compression air conditioners are largely made with chlorofluorocarbon refrigerants, or CFCs, which create problems for a world grappling with climate change. In addition, vapor compression air conditioners are driven by electricity. Cooling and heating represent one-third of building electrical energy consumption in US. An absorption chiller is different to vapor compression chillers or air conditioners because it doesn’t use conventional refrigerants, like CFC. Instead, they may use water as the refrigerant which is mixed with safe and nontoxic absorbents. The research performed in this project advanced the understanding of absorption cooling technology and its application in HVAC. Various technologies were explored to improve the performance of the desorber and absorber components in the absorption chillers.

42 ENGINEERING↗

The preservation of urine samples for determination of renal stone risk factors

A preservation technique for urine specimens before determination of stone risk factors was evaluated. The purpose of these experiments was to prove the effectiveness of the preservatives used to prevent changes in the concentrations of those constituents measured. Measured concentrations in fresh specimens were compared with those in the same specimens after storage with the preservatives. Refrigeration at 4 degrees C up to five days was appropriate in a laboratory setting, as no significant changes in urinary concentrations occurred. Refrigeration, however, did not offer a convenient method for shipping. Chemical preservation was found to be an effective alternative to refrigeration. Thymol prevented changes in concentration of pH, citrate, uric acid, sulfate, sodium, potassium, and cyclic AMP, while a mixture of hydrochloric (HCl) acid and boric acid prevented changes in calcium, magnesium, phosphorus, oxalate, ammonium, and creatinine. Thus, the addition of thymol or HCl/boric acid to urine specimens will prevent significant changes in the concentrations of stone risk factors.

Non-NASA Center↗

A chemical kinetic mechanism for combustion and flame propagation of CH 2 F 2 /O 2 /N 2 mixtures

Here in this work, we compiled and evaluated rate expressions for reactions relevant to the decomposition and combustion of CH 2 F 2 (difluoromethane, refrigerant R-32) in CH 2 F 2 /O 2 /N 2 flames. The recommended values have been used in premixed flame calculations, reported elsewhere, to model experimentally derived burning velocities determined using a constant volume spherical flame method. In this work, we also provide a detailed description of the reaction pathways for decomposition and combustion of CH 2 F 2 . This work is part of a larger effort at NIST to characterize and predict the flammability of new refrigerant working fluids and their blends for consideration as replacements of current refrigerants with high global warming potentials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development, calibration, and validation of a novel gray-box energy model for residential split air conditioners

Energy models for vapor compression refrigeration in residential air conditioners have been developed through white-box, gray-box, and black-box methods in decades. However, existing white-box and gray-box models require complicated equations with detailed geometries while black-box models require substantial experimental data. Further, this paper aims to develop and validate a simple gray-box steady-state energy model without the need for detailed geometries, which can accurately predict the cooling capacity and electrical power input based on outdoor and indoor air conditions, and supply airflow rates. First three state variables, including the evaporation and condensation temperatures, and refrigerant mass flowrate, are applied to develop the energy model and are solved by three physical equations, including the energy conservations at the evaporator and condenser, and the refrigerant volume-mass flow correlation of the compressor. Secondly, seven performance property functions related to three state variables and three physical equations are identified and calibrated by simple temperature and power measurements. Finally, field experiments are conducted on a residential air conditioner to calibrate these performance property functions and validate the developed model. The validated results reveal the model can accurately predict the cooling capacity and electrical power input, with the normalized root mean square errors of 2.3% and 0.87% respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On falling film evaporator – A review of mechanisms and critical assessment of correlation on a horizontal tube bundle with updated development

Optimization of the energy efficiency and reduction of the greenhouse gas emission for the heat pump system is imperative to meet the net-zero goals at 2050. Chillers with falling film evaporator design not only possess better system performance but also contain less refrigerant inventory. Hence, accurate prediction of the evaporator performance is pivotal especially when charged with low-GWP refrigerant. Here, the study reviews the correlations for falling film evaporator with a horizontal tube bundle configuration. The major efforts of this study include four tasks: (a) literature review of the experimental studies and available empirical correlations; (b) comprehensive discussion of the falling film evaporation heat transfer mechanism; (c) development of a new rationally based correlation based on available literature; and (d) comparison of different correlations based on the existing data. The collected data includes 4114 data points from 8 sources, 6 refrigerants (R-600a, R-290, R-245fa, R-134a, R-1234ze(E), R-123), 5 types of the tubes (Plain, Turbo-GII-HP, GEWA-B, Low-fin, High-Flux), liquid Weber number from 2.2 × 10 –6 to 0.7, imposed vapor Weber number from 0 to 37.2, heat flux from 2.5 to 151.5 kW/m 2 , and film Reynolds number from 1 to 3159.8. The new correlation gives a MAD of 28.3%, and an R 2 of 0.86. Yet, the developed correlation considers various heat transfer mechanisms, including the transition point from falling film evaporation to the nucleate boiling, local evaporation, dry-out, mist flow, imposed flow, and enhanced tube effects.

42 ENGINEERING↗

Active magnetic regenerative cooling with smaller magnets

Magnetocaloric heat pumping near room temperature, a.k.a. magnetic cooling, relies on the active regenerator cycle to achieve functional temperature spans and realize economic and societal benefits promised by this emerging solid-state cooling technology. The cycle itself depends upon synchronizing oscillating flow of a heat transfer fluid through a solid porous active material matrix, or the refrigerant, with periods when the refrigerant is in the highest available (field-on) and in nearly zero (field-off) magnetic fields to accomplish heat transfer. With this in mind, in this work we analyze varying flow and magnetic field wave forms and the timing between when the fluid is pumped and when the magnetic field is turned on and off. We demonstrate that the volume and the cost of permanent magnet generating the field changes can be cut nearly in half with little to no effect on the device temperature span and cooling power normalized by the refrigerant mass.

36 MATERIALS SCIENCE↗

Universal correlation for falling film evaporation on a horizontal plain tube

Falling film evaporators are widely used in many industrial sectors, such as desalination, refrigeration & air-conditioning, and chemical processes. The heat transfer correlations suitable for wider operating conditions and various refrigerants are useful for designing falling film evaporators. Although many researchers developed the correlation for their own experimental data, there is a limited universal correlation for falling film evaporators. In addition, the dry-out effects were not considered in the available universal correlations. Here, therefore, this study proposes a new correlation for falling film evaporation on a single horizontal plain tube, which includes nucleate boiling, film evaporation, and dry-out effects. The proposed correlation covers a wider range of operating conditions (Heat flux is of 2.5–168kWm -2 , and film Reynolds number is up to 3500), various refrigerants (R134a, R245fa, R1234ze(E), R123, R32, R410A, R290, and R600a), and the large number of experimental data (1101 data in total). The proposed correlation is validated against the available standard correlation with regard to mean absolute deviation (MAD) and R 2 values. The MAD of the new correlation is about 10%, respectively, which is the lowest among other correlations. Similarly, the R 2 showed a value of 0.92, which is the highest compared to the existing correlations. A simplified correlation is also proposed.

42 ENGINEERING↗

Scalable and Resilient Etched Metallic Micro- and Nanostructured Surfaces for Enhanced Flow Boiling

Flow boiling and evaporation in tubes and channels occur in a wide variety of energy systems, such as refrigeration, air conditioning, power generation, electronics cooling, distillation, and purification. In this work, we demonstrate remarkably increased heat transfer coefficients of 270% during refrigerant flow boiling in scalable microstructured (~40 µm), industrial-scale (~1 m long) aluminum (Al) tubes, when compared to smooth unstructured Al tubes. To achieve scalable nanomanufacturing, we create highly conformal and durable structured surfaces by relying on hydrochloric acid Al etching. Flow boiling tests were conducted in 6.35 mm diameter Al tubes using R134a refrigerant as the working fluid. To benchmark our approach and to elucidate the effect of the structure length scale, we also fabricated ultrascalable boehmite (AlO(OH)) nanostructured (~300 nm) Al tubes, showing that etched microscale features are necessary and key to enhancement. Durability tests conducted using a 28 day long continual flow boiling experiment demonstrated negligible degradation of the etched surfaces. The scalable and cost-effective techniques used to create these durable, etched-Al microstructures may significantly reduce manufacturing cost when contrasted with current enhancement approaches such as extrusion, drawing, and welding.

36 MATERIALS SCIENCE↗

Enhanced magnetocaloric performance in manganite bilayers

Bilayer films of La 0.8 Sr 0.2 MnO 3 and La 0.7 Ca 0.3 MnO 3 with different layer thicknesses and stacking sequences were synthesized via pulsed laser deposition. The magnetic properties and magnetocaloric effects were systematically investigated. We found that the phase transition associated with the layers tends to merge together at an optimal thickness and a stacking sequence. The operating temperature span of the entropy change broadens at the expense of its magnitude, leading to an enhancement of the refrigerant capacity by over 40%. The optimized bilayer film possesses a refrigerant capacity of ~6.0J/kg, compared to a value of ~4.2J/kg for the single-phase films. The phase transition broadening induced by epitaxial strain is responsible for the enhanced window of operating temperature as well as refrigerant capacity. Finally, the design principle developed here may be applied to ferroelastic and ferroelectric materials to enhance elastocaloric and electrocaloric effects.

36 MATERIALS SCIENCE↗

building-physics/refrigeration-system

The existing refrigeration system for OpenStudio was originally designed for a prototype supermarket model. To support the development of new modular space types, it is crucial to refactor the system. This process includes refining the design by utilizing the manufacturer's existing data, along with incorporating the latest data from manufacturers, to enhance the system’s adaptability and functionality. This repository currently contains the refrigeration system database and Python-based automation for generating OpenStudio-compatible refrigeration JSON files.

Bae, Yeonjin [Oak Ridge National Laboratory (ORNL)↗

Electrohydrodynamic Enabled Electrochemical Membrane Dehumidifier for Separate Sensible and Latent Cooling

In hot and humid parts of the world, air conditioning is a necessity for an adequate standard of living. Cooling and heating represent one-third of building energy consumption. When cooling humid air, a substantial amount of the cooling energy is absorbed by water vapor condensation. The dehumidification cooling load is referred to as the latent cooling load and the dry bulb cooling load is referred to as the sensible cooling load. In most residential applications, the total cooling load is processed by a vapor compression cycle. Processing the latent load separately would not only reduce energy consumption. It would also reduce the required refrigeration capacity. Refrigerants often have adverse ecological impacts, contributing to the greenhouse effect and depletion of the ozone layer. Reduction of the cooling capacity in a system could reduce the amount of refrigerant charge required.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Carbon Molecular Sieves Hollow Fiber Membranes based on Polybenzimidazole Doped with Polyprotic Acids with Superior H 2 /CO 2 Separation Properties (Final Report)

The goal of this project was to develop a highly efficient membrane-based process to capture CO 2 from coal-derived syngas with 95% CO 2 purity, achieving the cost of electricity (COE) 30% below the baseline capture approaches (i.e., Selexol process) when coupled with the advancement in other areas of the power generation facility. Our core approach is based on high-permeance hollow fiber membranes (HFMs) with superior H 2 /CO 2 separation properties at the syngas process conditions, which can then be further utilized to design membrane reactors for process intensification of H 2 production and purification and CO 2 capture. Three organizations with complementary skills collaborated to achieve the goal, including the University at Buffalo (UB), Los Alamos National Laboratory (LANL), and Trimeric Corporation (Trimeric). We formulated logical steps to bring the membrane technology from Technology Readiness Level (TRL) 3 (Experimental proof of concept) to TRL 4 (Laboratory scale validation in relevant environment). During the budget period (BP) 1, we screened various polymeric materials and identified polybenzimidazole doped with inorganic polyprotic acids as the desirable platform. The acid doping increases the H 2 /CO 2 selectivity, and the sequential carbonization increases H 2 permeability while retaining the high selectivity. By manipulating the acid type and doping level and the carbonization temperature, we demonstrated advanced carbon molecular sieving (CMS) materials with H 2 permeability of above 200 Barrer (1 Barrer = 10 -10 cm 3 (STP) cm cm -2 s -2 cmHg -1 ) and H 2 /CO 2 selectivity of above 40 at 200-300°C with simulated syngas containing CO and water vapor. For example, the PBI-(H 3 PO 4 ) 0.11 carbonized at 700 °C exhibits H 2 permeability of 200 Barrer and H 2 /CO 2 selectivity of 60 at 200 °C, and H 2 permeability of 240 Barrer and H 2 /CO 2 selectivity of 54 at 225 °C, which meets the targeted properties and surpasses Robeson’s upper bound. During the BP2, we focused on the conversion of the advanced CMS materials to stable HFMs. Membranes with H 2 permeance of 1,090 GPU (1 GPU = 10 -6 cm 3 (STP) cm -2 s -2 cmHg -1 ) and H 2 /CO 2 selectivity of 57 at 300 °C were successfully fabricated. The effects of temperature, gas compositions, pressure, and time on the separation properties were systematically investigated. Pencil modules were continuously evaluated for 219 h (dry pure gas) and 669 h (dry simulated syngas) and showed initial decline in permeance and increased H 2 /CO 2 selectivity over time, ultimately achieving a steady state stable value, indicating that the ageing phenomena in the nanoporous structures of the membranes during the test. Membrane reactors were fabricated based on the CMS membranes and evaluated for water-gas shift (WGS) reaction. The use of membranes slightly improves the conversion of the CO. However, parametric tests of the membrane reactors at various temperatures and flow rates need to be conducted, as well as the membranes with improved separation performance. We performed a sensitivity analysis on the impact of H 2 /CO 2 selectivity on the COE based on a hybrid process of a membrane unit and cryogenic unit developed by Membrane Technology and Research, Inc. (MTR). Three H 2 /CO 2 selectivity (40, 60, and 15) cases were developed and compared with the baseline capture process (Case B5B) provided by the DOE report. Increasing the membrane H 2 /CO 2 selectivity reduces COE, but the rate of the decrease of COE also diminishes. The COE values for H 2 /CO 2 selectivities of 40 and 60 were nearly the same. As the H 2 /CO 2 selectivity increases, the inert recycling decreases, leading to smaller equipment, less auxiliary power requirements, and less heating, cooling, and refrigeration duty. The refrigeration system used to liquefy the CO 2 is the most expensive piece of equipment and consumes the most electricity within the CO 2 capture process. Increasing the CO 2 concentration in the recycle stream would improve the economics of the process by reducing the refrigeration duty requirement of the unit and also allow for higher liquefaction temperatures. The high H 2 -selective membrane developed by our team may be applicable in other separation processes where lower pressure H 2 retains value. Typically, hydrogen retains its pressure when it is separated from syngas components. Residual components may be used as low-quality fuel and then vented to the atmosphere. Applications might include control of H 2 /CO ratios or mitigation of the water gas shift reaction by CO 2 recycling to the feed of a gasifier or steam methane reformer. To summarize, we have developed industrial HFMs with the best H 2 /CO 2 separation performance reported in the literature. The membranes demonstrate stability with simulated syngas and show great potential for membrane reactors for WGS reactions, lowering the cost of blue H 2 production.

20 FOSSIL-FUELED POWER PLANTS↗

Low Carbon Development Pathways for Cooling: Leveraging Kigali Amendment Across Residential Applications

Heating and cooling demand for space conditioning and refrigeration accounts for around a fifth of global final energy consumption. Climate change, urbanisation, and economic development have tripled electricity demand for cooling alone since the 1990s, with the majority coming from the use of inefficient cooling equipment, which burdens electricity grids, especially during the peak hours. It is imperative to address the energy required to provide cooling. The Kigali Amendment to the Montreal Protocol addresses these needs by setting ambitious global targets to phase down refrigerants with high global warming potential, while improving energy efficiency. Integrating energy efficiency and the refrigerant transition will contribute to economic security, well-being, energy access and security, and sustainability among the G20 countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High performance heat exchangers for next generation hybrid cooler (CRADA NFE-19-07891 Final Report)

The evaporative cooling process has been successfully deployed in multiple energy conversion processes such as power generation, process cooling, heating, ventilation & cooling (HVAC), and commercial and industrial refrigeration. The heat exchanger is a very common yet extremely critical component of such systems. The device is important since the performance of the overall cooling system heavily relies on the thermal-hydraulic efficiency of the heat exchanger. The possible wet operation as evaporative cooling heat exchanger complicates the issue. Indeed, based on the hybrid nature of operation (fully dry, partially wet, fully wet) the efficiency can vary significantly and can cause performance variation for the whole system. Understanding the importance of the issue, Oak Ridge National Laboratory (Contractor) and Baltimore Aircoil Company (Participant) propose an activity focused on the analysis of the existing heat exchanger technology used in air and evaporative cooling processes and design, development and demonstration of a novel heat exchanger design based on porous materials. The potential candidates include metallic wire meshes and metal foams carefully designed for the proposed application. Prior research has indicated that these materials have great potential for deployment in thermal systems, particularly heat sinks and heat exchangers. It is expected that the successful completion of the project will lead to novel heat exchanger technology for hybrid systems (capable of dry and wet operation) by exploring newly emerging materials and their potential for heat transfer application. The overall goal is to develop a next generation heat exchanger technology which can be deployed in evaporative cooling systems. The impact of the such development is significant since, it will not only make the overall system highly efficient but will also, reduce the total refrigerant charge in the heat exchanger, a critical aspect for the deployment of refrigerants with lower Global Warming Potential (GWP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High performance heat exchangers for next generation hybrid cooler (CRADA Final Report)

The evaporative cooling process has been successfully deployed in multiple energy conversion processes such as power generation, process cooling, heating, ventilation & cooling (HVAC), and commercial and industrial refrigeration. The heat exchanger is a very common yet extremely critical component of such systems. The device is important since the performance of the overall cooling system heavily relies on the thermal-hydraulic efficiency of the heat exchanger. The possible wet operation as evaporative cooling heat exchanger complicates the issue. Indeed, based on the hybrid nature of operation (fully dry, partially wet, fully wet) the efficiency can vary significantly and can cause performance variation for the whole system. Understanding the importance of the issue, Oak Ridge National Laboratory (Contractor) and Baltimore Aircoil Company (Participant) propose an activity focused on the analysis of the existing heat exchanger technology used in air and evaporative cooling processes and design, development and demonstration of a novel heat exchanger design based on porous materials. The potential candidates include metallic wire meshes and metal foams carefully designed for the proposed application. Prior research has indicated that these materials have great potential for deployment in thermal systems, particularly heat sinks and heat exchangers. It is expected that the successful completion of the project will lead to novel heat exchanger technology for hybrid systems (capable of dry and wet operation) by exploring newly emerging materials and their potential for heat transfer application. The overall goal is to develop a next generation heat exchanger technology which can be deployed in evaporative cooling systems. The impact of the such development is significant since, it will not only make the overall system highly efficient but will also, reduce the total refrigerant charge in the heat exchanger, a critical aspect for the deployment of refrigerants with lower Global Warming Potential (GWP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Compressor is A Sensor (Final Report)

The performance of the heat pump system varies greatly depending on the refrigerant charge amount. Improving the refrigerant charge fault detection and diagnostics (FDD) method of vapor compression systems have the potential for increasing energy efficiency and reducing service cost. Previous studies to predict refrigerant charge amount are mostly empirical methods which require significant amount of experimental data for high accuracy. The primary goal of this research is to develop a charge fault detection method which requires only a few experimental data with high prediction accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Frost Sensor for HVAC Applications

Frost is a common problem in heating, ventilation, and air conditioning (HVAC) systems that can degrade their efficiencies, leading to excessive electricity consumption. Appropriate defrosting is therefore essential for heat pumps and refrigeration systems. However, these systems typically run the defrost cycle based on a predetermined time interval, a method that does not accurately identify the amount of frost and thus consume excessive electricity. To substantially improve defrosting initiation and termination, this paper describes development of a smart sensor based on a capacitive sensing technique that can quantify frost accumulation and difference between frost, ice, and water. The reported sensor adopts interdigitated comb electrodes and can be updated to a potential multifunctional sensor array for the enhancing identification of frost, ice, and water with the integrated measurement of surface temperature, frost capacitance, and resistance. The proposed frost sensor is potentially expected to have widespread applications in HVAC systems, including heat pumps, refrigerators, and commercial refrigeration systems.

Gao, Zhiming↗