Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Scalable Experimental Bounds for Entangled Quantum State Fidelities

Estimating the state preparation fidelity of highly entangled states on noisy intermediate-scale quantum (NISQ) devices is important for benchmarking and application considerations. Unfortunately, exact fidelity measurements quickly become prohibitively expensive, as they scale exponentially as O(3 N for N-qubit states, using full state tomography with measurements in all Pauli bases combinations. However, Somma et al.established that the complexity could be drastically reduced when looking at fidelity lower bounds for states that exhibit symmetries, such as Dicke states and GHZ states. These bounds must still be tight enough for larger states to provide reasonable estimations on NISQ devices. For the first time and more than 15 years after the theoretical introduction, we report meaningful lower bounds for the state preparation fidelity of all Dicke states up to N=10 and all GHZ states up to N=20 on Quantinuum H1 ion-trap systems using efficient implementations of recently proposed scalable circuits for these states. Our achieved lower bounds match or exceed previously reported exact fidelities on superconducting systems for much smaller states. Furthermore, we provide evidence that for large Dicke states |$D^{N}_{N/2}\rangle$, we may resort to a GHZ-based approximate state preparation to achieve better fidelity. This work provides a path forward to benchmarking entanglement as NISQ devices improve in size and quality.

97 MATHEMATICS AND COMPUTING↗

Measurements of 3D slip velocities and plasma column lengths of a gliding arc discharge

A non-thermal gliding arc discharge was generated at atmospheric pressure in an air flow. The dynamics of the plasma column and tracer particles were recorded using two synchronized high-speed cameras. Whereas the data analysis for such systems has previously been performed in 2D (analyzing the single camera image), we provide here a 3D data analysis that includes 3D reconstructions of the plasma column and 3D particle tracking velocimetry based on discrete tomography methods. The 3D analysis, in particular, the determination of the 3D slip velocity between the plasma column and the gas flow, gives more realistic insight into the convection cooling process. Additionally, with the determination of the 3D slip velocity and the 3D length of the plasma column, we give more accurate estimates for the drag force, the electric field strength, the power per unit length, and the radius of the conducting zone of the plasma column.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Damage mapping in structural health monitoring using a multi-grid architecture

This paper presents a multi-grid architecture for tomography-based damage mapping of composite aerospace structures. The system employs an array of piezo-electric transducers bonded on the structure. Each transducer may be used as an actuator as well as a sensor. The structure is excited sequentially using the actuators and the guided waves arriving at the sensors in response to the excitations are recorded for further analysis. The sensor signals are compared to their baseline counterparts and a damage index is computed for each actuator-sensor pair. These damage indices are then used as inputs to the tomographic reconstruction system. Preliminary damage maps are reconstructed on multiple coordinate grids defined on the structure. These grids are shifted versions of each other where the shift is a fraction of the spatial sampling interval associated with each grid. These preliminary damage maps are then combined to provide a reconstruction that is more robust to measurement noise in the sensor signals and the ill-conditioned problem formulation for single-grid algorithms. Experimental results on a composite structure with complexity that is representative of aerospace structures included in the paper demonstrate that for sufficiently high sensor densities, the algorithm of this paper is capable of providing damage detection and characterization with accuracy comparable to traditional C-scan and A-scan-based ultrasound non-destructive inspection systems quickly and without human supervision.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrating Electrical Resistivity Tomography with Vadose Zone Characterization - 20246

The environmental management mission at the U.S. Department of Energy Hanford Site includes addressing subsurface contaminants that are present in the vadose zone because of historical waste discharges. Characterization is needed to support evaluation of whether contaminants at specific disposal sites will migrate to and contaminate the groundwater in the future. Drilling of boreholes and analysis of retrieved sediment samples is a standard approach to evaluating contaminant distribution in the vadose zone for the types of inorganic and radionuclide contaminants at the Hanford Site. However, borehole sampling has limitations for understanding the volumetric distribution of contaminants. The Hanford Site is now applying electrical resistivity tomography to characterize the path and volumetric extent of contaminant migration in the vadose zone. This information aids selection of appropriate locations for obtaining borehole samples and provides three-dimensional contaminant distribution information for incorporation into conceptual site models and to help configure fate and transport models. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantum Pair Generation in Nonlinear Metasurfaces with Mixed and Pure Photon Polarizations

Metasurfaces are highly effective at manipulating classical light in the linear regime; however, effectively controlling the polarization of nonclassical light generated from nonlinear resonant metasurfaces remains a challenge. Here, in this study, we present a solution by achieving polarization engineering of frequency-nondegenerate biphotons emitted via spontaneous parametric down-conversion in GaAs metasurfaces, utilizing quasi-bound states in the continuum (qBIC) resonances to enhance biphoton generation. Through comprehensive polarization tomography, we demonstrate that the emitted photons’ polarization directly reflects the qBIC mode’s far-field properties. Furthermore, we show that both the type of qBIC mode and the symmetry of the meta-atoms can be tailored to control each single-photon polarization state, and that the subsequent two-photon polarization states are nearly separable, offering potential applications in the heralded generation of single photons with adjustable polarization. This work provides a significant step toward utilizing metasurfaces to generate quantum light and engineer their polarization, a critical aspect for future quantum technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Equally sloped X-ray microtomography of living insects with low radiation dose and improved resolution capability

Three-dimensional X-ray imaging of living specimens is challenging due to the limited resolution of conventional absorption contrast X-ray imaging and potential irradiation damage of biological specimens. In this letter, we present microtomography of a living specimen combining phase-contrast imaging and a Fourier-based iterative algorithm termed equally sloped tomography. Non-destructive 3D imaging of an anesthetized living yellow mealworm Tenebrio molitor was demonstrated with a relatively low dose using synchrotron generated X-rays. Based on the high-quality 3D images, branching tracheoles and different tissues of the insect in a natural state were identified and analyzed, demonstrating a significant advantage of the technique over conventional X-ray radiography or histotomy. Additionally, the insect survived without problem after a 1.92-s X-ray exposure and subsequent absorbed radiation dose of ∼1.2 Gy. No notable physiological effects were observed after reviving the insect from anesthesia. The improved static tomographic method demonstrated in this letter shows advantage in the non-destructive structural investigation of living insects in three dimensions due to the low radiation dose and high resolution capability, and offers many potential applications in biological science.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance characterization of microtomography with complementary metal-oxide-semiconductor detectors for computer-aided defect inspection

We developed a computer-aided defect inspection system based on computed tomography (CT). The system consists of a homemade small cone-beam CT (CBCT) system and a graphical toolbox, which is used to extract a computer-aided design (CAD) model from the CT data. In the small CBCT system, the x-ray imaging detector is based on a complementary metal-oxide-semiconductor photodiode array in conjunction with a scintillator. Imaging performance of the detector was evaluated in terms of modulation-transfer function, noise-power spectrum, and detective quantum efficiency. The tomographic imaging performance of the small CBCT system was evaluated in terms of signal-to-noise ratio and contrast-to-noise ratio. The graphical toolbox to support defect inspection incorporates various functional tools such as volume rendering, segmentation, triangular-mesh data generation, and data reduction. All the tools have been integrated in a graphical-user interface form. The developed system can provide rapid visual inspection as well as quantitative evaluation of defects by comparing the extracted CAD file with the original file, if available, of an object. The performance of the developed system is demonstrated with experimental CT volume data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction 3-dimensional image from 2-dimensional image of status optical coherence tomography (OCT) for analysis of changes in retinal thickness

Optical Coherence Tomography is often used in medical image acquisition to diagnose that change due easy to use and low price. Unfortunately, this type of examination produces a two-dimensional retinal image of the point of acquisition. Therefore, this study developed a method that combines and reconstruct 2-dimensional retinal images into three-dimensional images to display volumetric macular accurately. The system is built with three main stages: data acquisition, data extraction and 3-dimensional reconstruction. At data acquisition step, Optical Coherence Tomography produced six *.jpg images of each patient were further extracted with MATLAB 2010a software into six one-dimensional arrays. The six arrays are combined into a 3-dimensional matrix using a kriging interpolation method with SURFER9 resulting 3-dimensional graphics of macula. Finally, system provides three-dimensional color graphs based on the data distribution normal macula. The reconstruction system which has been designed produces three-dimensional images with size of 481 × 481 × h (retinal thickness) pixels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of dynamic specimen shape evolution on the atom probe tomography results of doped epitaxial oxide multilayers: Comparison of experiment and simulation

The experimental atom probe tomography (APT) results from two different specimen orientations (top-down and sideways) of a high oxygen ion conducting Samaria-doped-ceria/Scandia-stabilized-zirconia multilayer thin film solid oxide fuel cell electrolyte was compared with level-set method based field evaporation simulations for the same specimen orientations. This experiment-simulation comparison explains the dynamic specimen shape evolution and ion trajectory aberrations that can induce density artifacts in final reconstruction, leading to inaccurate estimation of interfacial intermixing. This study highlights the importance of comparing experimental results with field evaporation simulations when using APT to study oxide heterostructure interfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Raster scanning and averaging for reducing the influence of speckles in optical coherence tomography

The application of small-angle raster scanning and averaging in the sample arm of the Michelson interferometer in optical coherence tomography (OCT) is described. Raster averaging is used to increase the signal-to-noise ratio and to reduce the speckle noise of the 2D OCT image in diagnostics of surface layers of human skin and subcutaneous blood vessels in vivo. The method allows using low-coherence source of low-power radiation and increasing the depth of human skin coherent probing up to 1.5 - 1.8 mm. The reduction of speckle noise in the obtained OCT image for the first time allowed visualisation of subcutaneous blood vessels at the entire depth of their localisation. (biophotonics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structural and optical study of Ce segregation in Ce-doped SiO{sub 1.5} thin films

Cerium doped SiO{sub 1.5} thin films fabricated by evaporation and containing silicon nanocrystals were investigated by atom probe tomography. The effect of post-growth annealing treatment has been systematically studied to correlate the structural properties obtained by atom probe tomography to the optical properties measured by photoluminescence spectroscopy. The atom probe results demonstrated the formation of Ce-Si rich clusters upon annealing at 900 °C which leads to a drastic decrease of the Ce-related luminescence. At 1100 °C, pure Si nanocrystals and optically active cerium silicate compounds are formed. Consequently, the Ce-related luminescence is found to re-appear at this temperature while no Si-nanocrystal related luminescence is observed for films containing more than 3% Ce.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Swept source optical coherence tomography for in vivo imaging and vibrometry in the apex of the mouse cochlea

Cochlear amplification has been most commonly investigated by measuring the vibrations of the basilar membrane in animal models. Several different techniques have been used for measuring these vibrations such as laser Doppler vibrometry, miniature pressure sensors, low coherence interferometry, and spectral-domain optical coherence tomography (SD-OCT). We have built a swept-source OCT (SS-OCT) system, which is similar to SD-OCT in that it is capable of performing both imaging and vibration measurements within the mouse cochlea in vivo without having to open the bone. In vivo 3D images of a mouse cochlea were obtained, and the basilar membrane, tectorial membrane, Reissner’s membrane, tunnel of Corti, and reticular lamina could all be resolved. We measured vibrations of multiple structures within the mouse cochlea to sound stimuli. As well, we measured the radial deflections of the reticular lamina and tectorial membrane to estimate the displacement of the outer hair cell stereocilia. These measurements have the potential to more clearly define the mechanisms underlying the linear and non-linear processes within the mammalian cochlea.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Visualisation of distribution of gold nanoparticles in liver tissues ex vivo and in vitro using the method of optical coherence tomography

The possibility of visualising the distribution of gold nanoparticles in liver by means of the method of optical coherence tomography is studied experimentally in model samples of beef liver in vitro and rat liver ex vivo. In the experiments we used the gold nanoparticles in the form of nanocages with resonance absorption in the near-IR spectral region. In the model studies the suspension of nanoparticles was applied to the surface of the sample, which then was treated with ultrasound. In the ex vivo studies the suspension of nanoparticles was injected to the laboratory rats intravenously. The image contrast and the optical depth of detection of blood vessels and liver structure components are calculated, as well as the depth of liver optical probing before and after the injection of nanoparticles. It was shown that the administration of the nanoparticle increases significantly the imaging contrast of liver blood vessels owing to the localisation of the nanoparticles therein.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical tomography of fluorophores in dense scattering media based on ultrasound-enhanced chemiluminescence

This letter proposes and demonstrates ultrasound-combined optical imaging in dense scattering media. A peroxyoxalate chemiluminescence system that includes fluorophores to chemically excite the pigment is stimulated by ultrasound irradiation with power of less than 0.14 W/cm{sup 2}. Using focused ultrasound, the chemiluminescence is selectively spatially enhanced, which leads to imaging of the pigment when embedded in a light-scattering medium via scanning of the focal point. The ultrasonically enhanced intensity of the chemiluminescence depends on the base intensity of the chemiluminescence without the applied ultrasound irradiation, which thereby enables quantitative determination of the fluorophore concentration. The authors demonstrate the potential of this method to resolve chemiluminescent targets in a dense scattering medium that is comparable to biological tissue. An image was acquired of a chemiluminescent target that included indocyanine green as the fluorophore embedded at a depth of 20 mm in an Intralipid-10% 200 ml/l solution scattering medium (the reduced scattering coefficient was estimated to be approximately 1.3 mm{sup −1}), indicating the potential for expansion of this technique for use in biological applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast tomographic methods for the tokamak ISTTOK

The achievement of long duration, alternating current discharges on the tokamak IST-TOK requires a real-time plasma position control system. The plasma position determination based on magnetic probes system has been found to be inadequate during the current inversion due to the reduced plasma current. A tomography diagnostic has been therefore installed to supply the required feedback to the control system. Several tomographic methods are available for soft X-ray or bolo-metric tomography, among which the Cormack and Neural networks methods stand out due to their inherent speed of up to 1000 reconstructions per second, with currently available technology. This paper discusses the application of these algorithms on fusion devices while comparing performance and reliability of the results. It has been found that although the Cormack based inversion proved to be faster, the neural networks reconstruction has fewer artifacts and is more accurate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast and low-dose computed laminography using compressive sensing based technique

Computed laminography (CL) is well known for inspecting microstructures in the materials, weldments and soldering defects in high density packed components or multilayer printed circuit boards. The overload problem on x-ray tube and gross failure of the radio-sensitive electronics devices during a scan are among important issues in CL which needs to be addressed. The sparse-view CL can be one of the viable option to overcome such issues. In this work a numerical aluminum welding phantom was simulated to collect sparsely sampled projection data at only 40 views using a conventional CL scanning scheme i.e. oblique scan. A compressive-sensing inspired total-variation (TV) minimization algorithm was utilized to reconstruct the images. It is found that the images reconstructed using sparse view data are visually comparable with the images reconstructed using full scan data set i.e. at 360 views on regular interval. We have quantitatively confirmed that tiny structures such as copper and tungsten slags, and copper flakes in the reconstructed images from sparsely sampled data are comparable with the corresponding structure present in the fully sampled data case. A blurring effect can be seen near the edges of few pores at the bottom of the reconstructed images from sparsely sampled data, despite the overall image quality is reasonable for fast and low-dose NDT.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Layout and first results of the nanotomography endstation at the P05 beamline at PETRA III

The Helmholtz-Zentrum Geesthacht operates the P05 Imaging Beamline at the DESY storage ring PETRA III. This beamline is dedicated to micro- and nanotomography with two endstations. This paper will present the nanotomography endstation layout and first results obtained from commissioning and test experiments. First tests have been performed with CRLs as X-ray objectives and newly developed rolled X-ray prism lenses as condenser optics. This setup allows a resolution of 100 nm half period with an effective detector pixel size of 15nm. A first tomograph of a photonic glass sample was measured in early 2014.

43 PARTICLE ACCELERATORS↗

Tunable semiconductor laser with two acousto-optic tunable filters in its external cavity

We report a laser with a linear external cavity containing a near-IR injection semiconductor optical amplifier as a gain element and two acousto-optic tunable filters (AOTFs) with quasi-collinear interaction of acoustic and light waves. At identical frequencies of RF signals that control the filters and ensure compensation for the Doppler frequency shift of light passing through the AOTFs, the steady-state laser emission linewidth can be reduced to about 25 MHz, which is almost three orders of magnitude smaller than that in the case of one filter (20 GHz). The position of the emission line, which remains narrow, slowly fluctuates within a spectral range about 3 GHz wide, which seems to be due to the large length of the external cavity and insufficient thermal stabilization of its components. This does not prevent us from obtaining light with a large coherence length. In emission wavelength sweep mode, the instantaneous emission linewidth increases with tuning rate, reaching 0.022 nm (8.8 GHz) at the highest tuning rate: 10{sup 4} nm s{sup −1}. In the case of automatic control over the output optical power at a level of 3 mW, the tuning range is 815 – 875 nm. Such instruments are of practical interest for optical coherence tomography, spectroscopy, optical metrology, and other application areas. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗