In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer

With a revived focus to create a permeant presence on the moon and in preparation for future Mars exploration, it is imperative that all re-sources are utilized to their fullest potential. In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen (O2) for not only breathable air, but also for rocket fuel. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith. Although there are numerous minerals within regolith and various processes to extract O2, this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2 (or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide (CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28. Approaches to differentiate isobaric components: Initially, the solution to overcome isobaric overlap was to use isotopic ratios, particularly be-tween carbon-13 and nitrogen-15. Although limited literature discuss isotopic composition and attempt to quantify the ratios, variation is particularly high and limited to a few lunar regolith samples. The following were identified as potential approaches to quantify isobaric species, N2 and CO, using our RGA. Threshold Ionization. CO and N2 both have peaks at m/z 28, but only N2 is capable of producing a peak at m/z 7. While a N2 peak at m/z 7 is generally rare, instrument parameters can be optimized in order to maximize the peak intensity. Typically a standard ionization energy of 70 eV is used to monitor a batch process and would produce reliable results for a majority of the reactants or products that we are interested in quantifying. However, to analyze the rare molecular fragment of N2 (N2+ at m/z 7), a different ionization energy may be beneficial. Threshold Ionization Mass Spectrometry (TIMS) will be explored to optimize the N2+ peak at m/z 7 by varying parameters such as ionization energy and pressure. Therefore, a quantitative value at m/z 7 will be used to determine the product gas concentration of N2, which will be subtracted from the total concentration determined at m/z 28 enabling us to approximate the amount of CO. Secondary Detector (infrared gas detector, IR). Another approach to quantitate and differentiate be-tween isobaric components is to leverage alternative modes of detection. Unlike mass spectrometry, which generally uses a separation step prior to analysis (i.e. gas chromatography), IR produces energy that is specifically absorbed depending on the bond and configuration of the molecule. This technique could be leveraged since it is generally only active on non-symmetric molecules, i.e. CO. Utilizing concentrations of CO determined from another detector could help correct concentrations of CO obtained from the QMS. However, the inclusion of another detector adds additional mission requirements, such as power, software changes and avionics updates that add additional cost and schedule requirements.

mass spectrometry↗

In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer

With a revived focus to create a permanent presence on the moon and in preparation for future Mars exploration, it is imperative that all resources are utilized to their fullest potential.[1] In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen(LO2) for not only breathable air, but also for rocket propellant. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith.[2],[3] Although there are numerous minerals within regolith and various processes to extract O2,this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2(or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide(CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28.

Mass Spectrometry↗

Precise calculations of the deuteron quadrupole moment

Recently, two calculations of the deuteron quadrupole moment have have given predictions that agree with the measured value to within 1%, resolving a long-standing discrepancy. One of these uses the covariant spectator theory (CST) and the other chiral effective field theory (cEFT). In this talk I will first briefly review the foundations and history of the CST, and then compare these two calculations with emphasis on how the same physical processes are being described using very different language. The comparison of the two methods gives new insights into the dynamics of the low energy NN interaction.

Gross, Franz L.↗

Design and Analysis of the PXIE CW Radio-frequency Quadrupole (RFQ)

The Project X Injector Experiment (PXIE) will be a prototype front end of the Project X accelerator proposed by Fermilab. PXIE will consist of an H- ion source, a low-energy beam transport (LEBT), a radio-frequency quadrupole (RFQ) accelerator , a medium-energy beam transport (MEBT) and a section of superconducting cryomodules that will accelerate the beam from 30 keV to 30 MeV. LBNL has developed an RFQ design for PXIE with fabrication scheduled to begin before the end of CY 2012. The chosen b aseline design is a four-vane, 4.4 m long CW RFQ with a resonant frequency at 162.5 MHz (2.4 wavelengths long). The RFQ will provide bunching and acceleration of a nominal 5 mA H- beam to 2.1 MeV. The relatively low wall power density results in wall powe r losses that are less than 100 kW. The beam dynamics design has been optimized to allow for more than 99% beam capture with exceptionally low longitudinal emittance. The RFQ mechanical design and the results of RF and thermal analyses are presented here.

43 PARTICLE ACCELERATORS↗

Quench protection of the first 4 m long prototype of the HL-LHC Nb3Sn quadrupole magnet

The quadrupole magnets for the LHC upgrade to higher luminosity are jointly developed by CERN and US-LARP (LHC Accelerator Research Program). These Nb3Sn magnets will be protected against overheating after a quench by a combination of heaters bonded to the coil outer surface and CLIQ (Coupling-Loss Induced Quench) units. The first 4 meter long prototype magnet, called MQXFAP1, was tested at the Brookhaven National Laboratory in stand-alone configuration. The magnet training campaign, consisting of 18 quenches, was interrupted due to the development of a short circuit between one heater strip and the coil. During the campaign, different quench protection schemes were implemented, including heaters attached to outer and inner layers, one CLIQ unit, and the energy-extraction system. The configuration including outer-layer heaters and CLIQ achieved the fastest current discharge, hence the lowest hot-spot temperature. The electro-magnetic and thermal transients after a quench were simulated with the program STEAM-LEDET and found in good agreement.

43 PARTICLE ACCELERATORS↗

Magnetic Analysis of the MQXF Quadrupole for the High Luminosity LHC

The high-luminosity upgrade of the large hadron collider (HL-LHC) requires new high-field and large-aperture quadrupole magnets for the low-beta inner triplets (MQXF). The US Hilumi-LHC Accelerator Upgrade (HL-LHC AUP) and CERN are jointly developing a 150 mm aperture Nb3Sn magnet. Due to the large beam size and orbit displacement in the final focusing triplet, MQXF has challenging field quality targets at collision energy. Magnetic measurements have been performed both at ambient and cryogenic temperatures in the four short models built and tested. This paper presents the magnetic analysis, comparing field measurements with the expectations and the field quality requirements. The analysis is focused on the geometrical harmonics and iron saturation effect, including three dimensional effects and transfer function repeatability. Persistent currents and dynamic effects are also discussed.

43 PARTICLE ACCELERATORS↗

Beam Tests of the PIP-II Injector Test Radio Frequency Quadrupole

In modern high intensity ion-particle accelerators, a Radio Frequency Quadrupole (RFQ) is utilized to prepare a high-quality beam for injection to the main accelerating section. Since an RFQ governs the initial beam parameters, characterization of the beam coming out from the RFQ is foremost step toward commissioning of an accelerator facili-ty. It allows validating the RFQ design as well as attaining a better understanding of charged-particle beams. This pa-per describes the beam-performance of the Proton Improvement Plan-II Injector Test (PIP2IT) Continuous Wave (CW) four vane-type RFQ. It is designed to operate at a frequency of 162.5 MHz and accelerate a nominal H- beam of 5 mA from 30 keV to 2.1 MeV. The paper details beam tests performed to validate the RFQ design specifications for trans-mission, beam kinetic energy and, RMS emittances. The paper also presents beam profile measurements and implica-tion of the beam-jitters on the effective beam emittance at the RFQ exit.

43 PARTICLE ACCELERATORS↗

Efficiency, Power Loss, and Power Factor Measurement of Quadrupole Magnet Power Supplies at the Spallation Neutron Source

The linear accelerator (LINAC) quadrupole magnets are powered by 42 silicon-controlled rectifier (SCR) based power supplies at the Spallation Neutron Source (SNS) facility of Oak Ridge National Laboratory. These 35V, 525A power supplies are bulky, inefficient and require both air and water cooling. The reliability of the SNS facility is impacted due to water leaks internal to power supplies and current readback issues associated with their unique control system interface, resulting in multiple downtime events. Hence, an alternate solution is necessary for the continued reliable operation of the SNS. To mitigate the above-mentioned problems, this paper proposes the use of off-the-shelf Switch Mode Power Supplies (SMPS) rated for 20V, 500A with serial control interface. These SMPS are air-cooled, more efficient and more compact owing to their switching speeds of approximately 160 kHz. The performance enhancements of the SMPS in comparison with the existing SCR power supply are discussed in detail in this paper. The features of the SMPS, along with experimental results for both power supplies, like efficiency, power losses and stability, are presented. Ongoing work is also discussed.

Harave, Sudarshan↗

Challenges and Lessons Learned from fabrication, testing and analysis of eight MQXFA Low Beta Quadrupole magnets for HL-LHC

By the end of October 2022, the US HL-LHC Accelerator Upgrade Project (AUP) had completed fabrication of ten MQXFA magnets and tested eight of them. The MQXFA magnets are the low beta quadrupole magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC. This AUP effort is shared by BNL, Fermilab, and LBNL, with strand verification tests at NHMFL. An important step of the AUP QA plan is the testing of MQXFA magnets in a vertical cryostat at BNL. The acceptance criteria that could be tested at BNL were all met by the first four production magnets (MQXFA03-MQXFA06). Subsequently, two magnets (MQXFA07 and MQXFA08) did not meet some criteria and were disassembled. Lessons learned during the disassembly of MQXFA07 caused a revision to the assembly specifications that were used for MQXFA10 and subsequent magnets. In this paper, we present a summary of: 1) the fabrication and test data of all the MQXFA magnets; 2) the analysis of MQXFA07/A08 test results with characterization of the limiting mechanism; 3) the outcome of the investigation, including the lessons learned during MQXFA07 disassembly; and 4) the finite element analysis correlating observations with test performance.

43 PARTICLE ACCELERATORS↗

Applied Metrology for the Assembly of the Nb3Sn MQXFA Quadrupole Magnets for the HL-LHC AUP

The US HL-LHC Accelerator Upgrade Project (AUP) is building Nb3Sn quadrupole magnets, called MQXFA, with plans to install 16 of them in the HL-LHC Interaction Regions. Variability in coil size must be dealt with at the assembly level, which requires timely and repeatable measurement of each coil. In this paper we will present the methodology used for coil measurements and the geometrical size data for the coils that have been measured thus far. We will also show the coil measurements of 8 coils before and after cold test. The Leica AT960-MR laser tracker with Spatial Analyzer software acquired to achieve these measurements has been used elsewhere in the project to great effect.

43 PARTICLE ACCELERATORS↗

High Power Radiofrequency Operation of the Radiofrequency Quadrupoles in the Spallation Neutron Source

The Spallation Neutron Source (SNS) recently took delivery of a third Radiofrequency Quadrupole (RFQ03) that will ultimately be installed on the front-end (FE) of the SNS Linac. The first RFQ (RFQ01) operated in the SNS FE for more than a decade before being replaced with the second RFQ (RFQ02). RFQ01 was relocated to the Beam Test Facility (BTF) where it operated for five more years. The RFQ02 was initially installed in the BTF for high power testing and used with H- beam for BTF operation. It replaced RFQ01 in the SNS FE in 2017 and has been operating for beam production since then. There are some differences between the three RFQs. RFQ01 has a square cross-section with pi-mode stabilizing loops (PISLs) with the structure being fabricated using two layers of materials, GlidCop outside and OFHC inside. RFQ02 and RFQ03 has an octagonal cross-section with end-wall stabilizer rods and was fabricated using OFHC only. RFQ01 suffered some field flatness distortion incidents that resulted in degradation in beam transmission efficiency and required RF tuning. RFQ02 has performed well but had a melted RF seal in the high energy end wall, that was ultimately mitigated by a redesign of the end flange seals. The SNS decided to order RFQ03 that has a design that followed that of RFQ02 closely, but end-wall contacts were modified to prevent RF seal failure. This report presents the testing, installation, high power RF operation, and design improvements of the RFQ03.

Ren, Haitao↗

Fermilab Booster Beam Emittances from Quadrupole Modes Measured by BPMs

The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and requires a lot of tuning to extract out the emittances. In this paper, an improved method where multiple BPMs are used together with better mathematical analysis is described. The BPM derived emittances are then compared with those measured by the Ion Profile Monitor (IPM). Surprisingly, the BPM measured emittances behave very well and are more realistic than those measured by the IPM.

43 PARTICLE ACCELERATORS↗

A novel approach to RF power coupling in Radio-Frequency Quadrupole (RFQ) structures: built-in coaxial double-loop coupling port

Efficient and reliable RF power couplers in accelerating cavities require precise impedance matching and mechanical stability to ensure optimal beam energy transfer. In radio-frequency quadrupole (RFQ) accelerators, power is commonly delivered using waveguide iris or coaxial loop couplers. Iris couplers can handle high RF power but lack tunability, while coaxial loop couplers offer tuning flexibility but are limited in power handling and thermal performance. We propose a new RFQ power coupling concept utilizing a single input coaxial center-fed double-loop antenna built into a vane in an RFQ structure . The design integrates back-to-back loops into the RFQ vanes, fed by a TEM coaxial transmission line with standard 50-Ω characteristic impedance. The configuration can allow straightforward and easy ceramic window replacement without retuning, and coupling strength is adjusted with protruding tuning rods. Numerical simulations, performed with both a simplified RFQ model and the Spallation Neutron Source RFQ, demonstrate improved RF performance and reduced dipole mode excitation. The results establish the coaxial double-loop coupler as a practical alternative for high-power RFQ coupling applications.

Lee, Sung-Woo [ORNL] (ORCID:000000030915835X)↗

Electron Transfer Dissociation of All Ions at All Times, MS{sup ETD}, in a Quadrupole Time-of-Flight (Q-ToF) Mass Spectrometer

Data-independent mass spectral acquisition is particularly powerful when combined with ultra-performance liquid chromatography (LC) that provides excellent separation of most components present in a given sample. Data-independent analysis (DIA) consists of alternating full MS scans and scans with fragmentation of all ions within a selected m/z range, providing precursor masses and structure information, respectively. Fragmentation spectra are acquired either by sequential isolation and fragmentation of sliding m/z ranges or fragmenting all ions entering the MS instrument with no ion isolation, termed broadband DIA. Previously, broadband DIA has only been possible using collision induced dissociation (CID). Here, we report the use of electron transfer dissociation (ETD) as the fragmentation technique in broadband DIA instead of traditional collision induced dissociation (CID) during MS{sup E}. In this approach, which we refer to as MS{sup ETD}, we implement the inherent benefits provided by ETD, such as discrimination of leucine and isoleucine, in a DIA setup. The combination of DIA analysis and ETD fragmentation with supplemental CID energy provides a powerful platform to obtain information on all precursors and their sequence from a single experiment. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Desorption Ionization Quadrupole Ion Trap Time-of-Flight Mass Spectrometry of Au{sub m}Fe{sub n}{sup +/–} Clusters Generated from Gold-Iron Nanoparticles and their Giant Nanoflowers. Electrochemical and/or Plasma Assisted Synthesis

Gold nanoparticles (NP) with average diameter ~100 nm synthesized from tetrachloroauric acid solution using stainless steel as a reducing agent were found to contain iron. Applying simultaneously high frequency (HF) plasma discharge in solution during the electrochemical reduction, giant gold-iron nanoflowers with average size ~1000–5000 nm were formed. Scanning electron microscopy (SEM) shows the morphology of the nanopowders produced as polygonal yet nearly spherical, whereas iron content in both products determined by energy dispersive X-ray analysis (EDX) was found to be at ~2.5 at. %. Laser desorption ionization (LDI) of both nanomaterials and mass spectrometric analysis show the formation of Au{sub m}Fe{sub n}{sup +/–} (m = 1–35; n = 1–3) clusters. Structure of few selected clusters in neutral or monocharged forms were computed by density functional theory (DFT) calculations and it was found that typical distances of an iron nucleus from adjacent gold nuclei lie in the interval 2.5 to 2.7 Å. Synthetized Au-Fe nanoparticles were found stable for at least 2 mo at room temperature (even in aqueous solution) without any stabilizing agent. Produced Au-Fe nanoparticles in combination with standard MALDI matrices enhance ionization of peptides and might find use in nanomedicine. .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Matrix Assisted and/or Laser Desorption Ionization Quadrupole Ion Trap Time-of-Flight Mass Spectrometry of WO{sub 3} Clusters Formation in Gas Phase. Nanodiamonds, Fullerene, and Graphene Oxide Matrices

The formation of W{sub x}O{sub y}{sup +●/-●} clusters in the gas phase was studied by laser desorption ionization (LDI) and matrix assisted laser desorption ionization (MALDI) of solid WO{sub 3}. LDI produced (WO{sub 3}){sub n}{sup +●/-●} (n = 1-7) clusters. In MALDI, when using nano-diamonds (NDs), graphene oxide (GO), or fullerene (C{sub 60}) matrices, higher mass clusters were generated. In addition to (WO{sub 3}){sub n}{sup -●} clusters, oxygen-rich or -deficient species were found in both LDI and MALDI (with the total number of clusters exceeding one hundred ≈ 137). This is the first time that such matrices have been used for the generation of(WO{sub 3}){sub n}{sup +●/-●} clusters in the gas phase, while new high mass clusters (WO{sub 3}){sub n}{sup -●} (n = 12-19) were also detected. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser Ablation Generation of Antimony Selenide Clusters: Laser Desorption Ionization (LDI) Quadrupole Ion Trap Time of Flight Mass Spectrometry

The binary system Sb-Se was studied via laser ablation using antimony-selenium mixtures made from powdered elements in various ratios generating new Sb{sub m}Se{sub n} clusters. The results show that in addition to Sb{sub m}{sup +} (m = 1–8) and Se{sub n}{sup +} (n = 2–9) clusters, a series of Sb{sub m}Se{sub n}{sup +} clusters such as SbSe{sub 1–8}{sup +}, Sb{sub 2}Se{sub 1–6}{sup +}, Sb{sub 3}Se{sub 1–5}{sup +}, Sb{sub 4}Se{sub 1–3}{sup +}, and Sb{sub 5}Se{sub 1,2}{sup +} is generated. In addition, some low intensity oxidized clusters like Se{sub 6}O{sub 2}{sup +}, Se{sub 7}O{sub 2}{sup +}, and SbSe{sub 2-6}O{sub 5}{sup +} and partially hydroxylated clusters (SbSeO{sub 2}H{sub 7}{sup +}, SbSe{sub 5}O{sub 4}H{sup +}) are also formed. In total, 24 new antimony selenide clusters were generated. The knowledge gained can contribute to the elucidation of the structure of Sb{sub m}Se{sub n} glasses. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗