Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pv module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Mechanisms of adhesion degradation at the photovoltiac module's cell metallization-encapsulant interface

Adhesion measurements and chemical characterization of the encapsulant/silver metallization interface of a photovoltaic (PV) module through temperature, humidity, and voltage bias exposures were conducted. Results demonstrate two independent degradation mechanisms: (a) with voltage bias, the ionic conduction of Na + ions through the encapsulant results in the formation of sodium silicate at the silver metallization surface, thereby weakening that interface and (b) with moisture ingress, dissociation of the silane bonding to silver in the silver oxide similarly weakens this interface resulting in significantly lower debond energies.

14 SOLAR ENERGY↗

The Role of Water on the Interfacial Adhesion in Si Solar Modules

Delamination of solar module interfaces often occurs in field-tested solar modules after decades of service due to environmental stressors such as humidity. As water diffuses into the module, failure mechanisms like corrosion and delamination are significantly affected. In the presence of water, the interfaces between EVA and the cell, glass, and backsheet all experience losses of adhesion exposing the module to accelerated degradation. Understanding the relation between interfacial adhesion and water content inside PV modules can help mitigate detrimental power losses. Water content measurements via short wave infrared reflectometry combined with 180 degrees peel tests were used to study and quantify the effect of water ingress and egress on adhesion. Changes in adhesion strength for different module interfaces are quantified, correlating spatial distribution of water content to adhesion for damp heat and dry heat exposed samples. After 1000 hours of damp heat exposure, decreases in adhesion strength of approximately 1 N/mm were noted for all interfaces.

adhesion↗

Upstream Extraction of Tellurium from Copper Concentrates

A major barrier to increasing CdTe PV module production is the availability of tellurium (Te), an element necessary to manufacture CdTe PV cells that currently has a very limited supply. Most Te is obtained from ore extracted for copper mining, but the current processing methods only extract 3-4% of the available Te in this ore, with the rest being discarded during other processing steps. This project aims to increase Te supply by developing an innovative extraction method that will recover more Te from the copper ore earlier in the process. This method will also extract toxic elements like antimony and arsenic, making the copper mining process more environmentally friendly.

14 SOLAR ENERGY↗

Updates to the Instant Online PV LCOE Calculator Tool

Levelized cost of energy (LCOE) is an important metric for techno-economic analysis of PV modules, systems, and performance. An NREL team within DuraMAT has developed a simplified PV-specific LCOE calculator as an alternative to the NREL System Advisor Model (SAM) for applications that do not have the degree of detail required by SAM. This webinar will review recent data and new features that have been added to the simplified calculator this year, including breakeven buttons, commercial system options, and inverter loading ratios. It will also review the structure of the source code on GitHub, how to edit a local version of the calculator, and walk through some example use cases for the calculator.

calculator↗

Proposed Junction-Box Stress Test (Using an Added Weight) for Use During the Module Qualification (Presentation)

Engineering robust adhesion of the junction-box (j-box) is a hurdle typically encountered by photovoltaic (PV) module manufacturers during product development. Furthermore, there are historical incidences of adverse effects (e.g., fires) caused when the j-box/adhesive/module system has failed in the field. The addition of a weight to the j-box during the 'damp heat' IEC qualification test isproposed to verify the basic robustness of the j-box adhesion system. The details of the proposed test are described, in addition to the preliminary results conducted using representative materials and components.

14 SOLAR ENERGY↗

Degradation in PV Encapsulation Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test

Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PV installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.

14 SOLAR ENERGY↗

Trial Run of a Junction-Box Attachment Test for Use in Photovoltaic Module Qualification (Presentation)

Engineering robust adhesion of the junction-box (j-box) is a hurdle typically encountered by photovoltaic (PV) module manufacturers during product development and manufacturing process control. There are historical incidences of adverse effects (e.g., fires), caused when the j-box/adhesive/module system has failed in the field. The addition of a weight to the j-box during the 'damp-heat', 'thermal-cycle', or 'creep' tests within the IEC qualification protocol is proposed to verify the basic robustness of the adhesion system. The details of the proposed test are described, in addition to a trial run of the test procedure. The described experiments examine 4 moisture-cured silicones, 4 foam tapes, and a hot-melt adhesive used in conjunction with glass, KPE, THV, and TPE substrates. For the purpose of validating the experiment, j-boxes were adhered to a substrate, loaded with a prescribed weight, and then subjected to aging. The replicate mock-modules were aged in an environmental chamber (at 85 deg C/85% relative humidity for 1000 hours; then 100 degrees C/<10% relative humidity for 200 hours) or fielded in Golden, Miami, and Phoenix for 1 year. Attachment strength tests, including pluck and shear test geometries, were also performed on smaller component specimens.

14 SOLAR ENERGY↗

Annual Supply Chain for Photovoltaics (ASC-PV) in the United States: 2024 in Review

This report analyzes U.S. PV and BESS supply chains and costs in 2024, for PV module and battery technologies, structural and electrical balance of system (BOS) components, as well as PV recycling. The report concludes with an analysis of technology installation trends, government support for domestic manufacturing, manufacturing jobs, and the domestic content of PV systems installed in the United States in 2024.

14 SOLAR ENERGY↗

Characterization of Multicrystalline Silicon Modules with System Bias Voltage Applied in Damp Heat

As it is considered economically favorable to serially connect modules to build arrays with high system voltage, it is necessary to explore potential long-term degradation mechanisms the modules may incur under such electrical potential. We performed accelerated lifetime testing of multicrystalline silicon PV modules in 85 degrees C/ 85% relative humidity and 45 degrees C/ 30% relative humiditywhile placing the active layer in either positive or negative 600 V bias with respect to the grounded module frame. Negative bias applied to the active layer in some cases leads to more rapid and catastrophic module power degradation. This is associated with significant shunting of individual cells as indicated by electroluminescence, thermal imaging, and I-V curves. Mass spectroscopy resultssupport ion migration as one of the causes. Electrolytic corrosion is seen occurring with the silicon nitride antireflective coating and silver gridlines, and there is ionic transport of metallization at the encapsulant interface observed with damp heat and applied bias. Leakage current and module degradation is found to be highly dependent upon the module construction, with factors such asencapsulant and front glass resistivity affecting performance. Measured leakage currents range from about the same seen in published reports of modules deployed in Florida (USA) and is accelerated to up to 100 times higher in the environmental chamber testing.

14 SOLAR ENERGY↗

Direct Current Arc-Flash Hazards of Solar Photovoltaic Systems

An arc-flash is a rapid release of thermal energy, pressure waves, and electromagnetic interference from a high-power electrical system, caused by such events as unintentional shorting or equipment malfunction. Arc-flashes are hazardous to people and equipment. Incident energy (IE) is a means of quantifying the degree of thermal hazard posed by an arc-flash event. The calculated IE value dictates what level of personal protective equipment (PPE) workers are required to wear when servicing equipment. Overly burdensome PPE may increase a worker’s discomfort and decrease dexterity, which could lead to unintentional shorting, while inadequate PPE also comes with increased safety risks. The majority of arc-flash research to date has focused on alternating current (ac) systems. For example, IE calculations and PPE for ac systems are relatively well understood and have been applied across many equipment types and voltages. IE calculation methodologies in ac systems are backed by a wide range of industry tests and are included in Institute of Electrical and Electronics Engineers (IEEE) and National Fire Protection Association (NFPA) standards. However, very little is known about direct current (dc) arc-flash and its hazards. This is a significant knowledge gap, as an increasing number of dc systems are being deployed: solar photovoltaic (PV) plants, battery storage, and electric vehicles and their charging infrastructure. The dc arc-flash hazard publications are rooted primarily in theory, and their IE calculation methods contradict each other. Insufficient knowledge and data are preventing the formation of industry consensus and standards around dc arc-flash hazard assessment. Here, this white paper highlights the current status and research opportunities for assessing arc-flash hazards in dc systems, with a focus on PV plants. The nonlinear current-voltage characteristics of PV modules make them unique in comparison to other linear dc sources, such as batteries. Also, PV equipment has rapidly evolved from 600 Vdc to 1,500 Vdc (in the United States), increasing potential arc-flash hazards. The operating regime of a PV-array within its I-V characteristic curve during an arc-flash event and the sustainability of arc-flash events in a utility-scale PV plant need to be investigated. Arc-flash experiments on a 1-MWdc nameplate capacity utility-owned ground-mount photovoltaic plant suggest that the PV array acts as a constant-current supply with currents near the short-circuit portion of the I-V characteristic curve of the array, with median arc voltage as 1/3 of the rated voltage. Various engineering software packages (CYME7 by EATON, PTW by SKM, ArcFlash™ by EasyPower, ETAP, and so on) have started offering dc arc-flash calculation features to estimate the risk of arc-flash in dc and PV systems. However, they are reliant on the same simplified arc-flash models, which contradict each other due to differences in assumptions such as characteristics of the power source, arc current, voltage and impedance, arc-operating regime, and so on. Physical arc-flash testing and improved physics-based modeling with correct assumptions representing practical scenarios are two methods to improve understanding and quantify the risks associated with dc arc-flash hazards. The results would inform development of a more accurate calculation procedure for IE and proper PPE levels.

14 SOLAR ENERGY↗

Evaluation of the PID-s Susceptibility of Modules Encapsulated in Materials of Varying Resistivity

A common mechanism of potential-induced degradation is by shunting (PID-s) in PV modules, usually associated with the transport of sodium ions (Na+) through the encapsulant and penetrating the front junction of solar cells under voltage stress. Encapsulants with high volume resistivity have been suggested as a potentially cost-effective solution to this degradation mechanism. In this work, we examine three polyolefin elastomer (POE) encapsulants with volume resistivity varying over two orders of magnitude (ranging from 9 x 10^13 to 1 x 10^16 ..omega.. cm) that show equivalent and complete resistance to PID at the damp heat stress test level of 85 degrees C and 85% relative humidity and -1000 V system voltage stress. Performance is compared with a PID-susceptible ethylene vinyl acetate (EVA) encapsulant with resistivity 1 x 10^13 ..omega.. cm. The independence of PID susceptibility with respect to the resistivity of the polyolefin is attributed to the impermeability of POEs to Na + ions. Specific ions (i.e. Na + ), rather than charge-carrying species in general, are responsible for this degradation mechanism.

14 SOLAR ENERGY↗

Durable Module Materials (DuraMAT) Consortium (Final Technical Report)

The DuraMAT Consortium brings together DOE national lab and university research capabilities with the photovoltaic (PV) and supply-chain industries to accelerate a sustainable, just, and equitable transition to zero carbon electricity generation by 2035 through our five core objectives: development of a central data resource for PV modules, multi-scale and multi-physics modeling, disruptive acceleration science, forensic tools for fielded modules, and materials solutions for more durable, reliable, and resilient modules.

14 SOLAR ENERGY↗

Review of the environmental effects of the Space Station Freedom photovoltaic power module

An overview is provided of the environment in the low Earth orbit (LEO), the interaction of this environment with the Photovoltaic (PV) Power system of the Space Station Freedom is reviewed, and the environmental programs are described that are designed to investigate the interactions of the LEO environment with the photovoltaic power system. Such programs will support and impact the design of the subsystems of the PV module in order to survive the design lifetime in the LEO natural and induced environment.

Nahra, Henry K.↗

Review of the environmental effects on the Space Station Freedom photovoltaic power module

An overview is provided of the environment in the low earth orbit (LEO), the interaction of this environment with the photovoltaic (PV) power system of the Space Station Freedom is reviewed, and the environmental programs are described that are designed to investigate the interaction of the LEO environment with the photovoltaic power system. Such programs will support and impact the design of the subsystems of the PV module in order to survive the design lifetime in the LEO natural and induced environment.

Nahra, Henry K.↗

Uncertainty Quantification of Bifacial Performance Modeling

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

energy modeling↗

Uncertainty Quantification of Bifacial Performance Modeling

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

bifacial↗

Uncertainty Quantification of Bifacial Performance Modeling: Preprint

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

energy modeling↗