Decommissioning of the V1 Nuclear Power Plant Jaslovske Bohunice - 20270

The paper focuses on introducing the approach and method applied for decommissioning of the V1 nuclear power plant (further the 'V1 NPP') located in Jaslovske Bohunice in the Slovak Republic, to the conference participants. The Paper outlines activities and steps necessary to comply with the requirements contained in the decision of the Slovak government from 1999 regarding the early shutdown of the V1 NPP. The company responsible for the V1 NPP decommissioning is Jadrova a vyradovacia spolocnost, a.s., (further JAVYS) with the State as a sole shareholder. On the basis of the V1 NPP Decommissioning Conceptual Plan, out of four assessed options, JAVYS selected the immediate decommissioning option (the 'IDO') for the V1 NPP. On the basis of multi-criteria analysis, the IDO specified the approach of immediate and continuous dismantling of equipment followed by demolition of buildings and preparation of the site for its further potential use. The IDO also included the summary of technical, environmental, legislative information as well as the determination of assumed costs for decommissioning of the V1 NPP. Prior to commencement of the V1 NPP decommissioning, within the process of termination of operation, activities connected with de-fuelling, monitoring, processing of historical waste and, not to forget, the process of obtaining the license for the V1 NPP decommissioning were executed. JAVYS decided to divide the decommissioning process into two stages. In 2011, JAVYS obtained a license for the first stage of the V1 NPP decommissioning. Within this stage, dismantling of inactive equipment, demolitions of inactive buildings, monitoring of systems and preparatory works for the upcoming stage of decommissioning were implemented. In 2015, in line with the license for the 2. stage of the V1 NPP decommissioning, the activities of decontamination and dismantling of contaminated and active equipment as well as demolitions of remaining buildings began. In this stage radioactive waste (RAW) produced during the decommissioning is to be processed. After decontamination, the material fulfilling the free release criteria is to be released into the environment, the site is to be cleared from the scope of the Atomic Act and released from the surveillance of the national regulators. Future application of certain methods and techniques for decontamination and dismantling in similar environments might bring an added value to the operators. Paper includes a description of best practices for Nuclear Power Plant VVER type reactors decommissioning. Schedule comparison is given to show how the critical path of certain projects is being managed. Application of the International Standard for Decommissioning Costing (ISDC) methodology provides a uniform method which enables comparison of cost estimates to other nuclear facilities under decommissioning. The cost estimate for the V1 NPP decommissioning has been continuously updated based on more advanced and detailed information on the decommissioning activities and projects. Monitoring of progress of the V1 NPP decommissioning is performed via four key-performance indicators. The Earned Value Management (EVM) methodology is used for evaluating time and cost aspect of decommissioning activities while waste conditioning index is calculated by comparing the actually produced waste to planned values of waste for a respective monitored period. Radiological safety index is assessed by comparison of the personnel records on the individual yearly doses received by each respective employee to the boundary value. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Hardware-in-The-Loop Testbed for a Decentralized, Data-Driven Electric Vehicle Charging Control Algorithm

This study presents the design of an electric vehicle (EV)-grid integration (EVGI) hardware test-bed to implement smart EV charging algorithms. Here, the proposed test-bed also allows to create different grid events via flexible integration of other power hardware (e.g., controllable loads and battery energy storage systems) and test their impacts on EV charging. The design uses a real-time digital simulator to realize a complex distribution grid model with primary and secondary networks. A grid simulator physically realizes the selected nodes of the simulated grid to power an actual EV, forming a hardware-in-the-loop (HIL) test setup. The EV-grid integration is demonstrated based on the custom hardware and software implementation of the J1772 charging protocol using dSPACE MicroLabBox, operating as a custom EV Supply Equipment (EVSE). The HIL test-bed features a novel testing platform for accurate implementation and analysis of scalable charging algorithms. To this end, a data-driven, decentralized, model-free charging controller based on the Additive Increase and Multiplicative Decrease (AIMD) algorithm is presented and validated on an EV using the HIL test-bed. We tested the proposed algorithm under various case studies, and presented a comparison study with an existing droop-based, decentralized charging solution. The results showed that the EV successfully performed charging commands generated by the EVSE and regulated its charging power to effectively reduce the system loading caused by high EV penetration.

33 ADVANCED PROPULSION SYSTEMS↗

Complete Performance Comparison Between the Optimized Image Construction Algorithm (U-MBIR) and the Existing Reconstruction Algorithm for Detecting Defects and Damage in Concrete

Reinforced concrete (RC) is a composite material subjected to mechanical, thermal, and chemical loads throughout its service life. Because of these external stressors and the susceptibility of RC structural members to shrinkage and microcracking, the material degrades throughout its life cycle. This deterioration can lead to a decrease in member capacity and, ultimately, poses a threat to the structural integrity. Thus, it is crucial that the damage caused by aging and degradation be monitored and assessed at regular intervals throughout the material’s service life. Since coring of the material is typically not feasible for in-service structural systems, non-destructive evaluation (NDE) methodologies are used to assess remaining structural capacity. NDE methods enable surface and subsurface examination without damaging or degrading the medium. Moreover, RC is a critical component of nuclear power plants; thus, its safety and reliability must be thoroughly examined throughout the life cycle of the structural system. Ultrasonic measurements have been an industry standard for both surface and subsurface inspections. To this end, Oak Ridge National Laboratory (ORNL) has researched and developed advanced image reconstruction algorithms to capture internal damage. The results and discussion presented herein summarize the current state of the ultrasonic model–based iterative reconstruction (U-MBIR) algorithm developed at ORNL. More specifically, this report presents a comparison between reconstruction images produced via a widely employed ultrasonic NDE technique—the synthetic aperture focusing technique (SAFT)—and the ORNL-developed U-MBIR algorithm. These NDE methodologies are demonstrated using ultrasonic data collected from four concrete specimens. Overall, the U-MBIR algorithm eliminates artifacts and noise that are typically present within the SAFT reconstructions, and it shows defects and anomalies more clearly than the SAFT images. In conclusion, this algorithm is suitable for identifying concrete defects, although more improvements and optimization could be done to better define internal defects.

36 MATERIALS SCIENCE↗

The Early Light Curve of the Type Ia Supernova 2021hpr in NGC 3147: Progenitor Constraints with the Companion Interaction Model

The progenitor system of Type Ia supernovae (SNe Ia) is expected to be a close binary system consisting of a carbon/oxygen white dwarf (WD) and a nondegenerate star or another WD. Here, we present results from high-cadence monitoring observations of SN 2021hpr in a spiral galaxy, NGC 3147, and constraints on the progenitor system based on its early multicolor light-curve data. First, we classify SN 2021hpr as a normal SN Ia from its long-term photometric and spectroscopic data. More interestingly, we found a significant "early excess" in the light curve over a simple power-law ~t 2 evolution. The early light curve evolves from blue to red to blue during the first week. To explain this, we fitted the early part of the BVRI-band light curves with a two-component model consisting of ejecta–companion interaction and a simple power-law model. The early excess and its color can be explained by shock-cooling emission due to a companion star having a radius of 8.84 ± 0.58 R ⊙ . We also examined Hubble Space Telescope preexplosion images, finding no detection of a progenitor candidate, consistent with the above result. However, we could not detect signs of a significant amount of stripped mass from a nondegenerate companion star (≲0.003 M ⊙ for Hα emission). The early excess light in the multiband light curve supports a nondegenerate companion in the progenitor system of SN 2021hpr. At the same time, the nondetection of emission lines opens the door for other methods to explain this event.

79 ASTRONOMY AND ASTROPHYSICS↗

Online Tracking of Two Dominant Inter-Area Modes of Oscillation in the Eastern Interconnection

Reliable power system operation requires that small-signal stability be maintained at all times. Mode meters are measurement-based tools that provide operators with situational awareness of the system's stability margin. They operate by continually tracking the inter-area modes of oscillation that govern small-signal stability. This paper reports on the deployment of mode meters for online monitoring of two dominant modes of oscillation in the United States' Eastern Interconnection (EI). The use of measurements from system operators across the interconnection to provide continuous tracking is novel in the EI. Results from over four months of analysis reveal diurnal patterns in the modes and demonstrate that they can be tracked through a variety of system conditions. The results from this study continue to build an understanding of the EI's modes that will inform future modeling and monitoring efforts.

Follum, James D.↗

Power System Event Detection Using the Energy Detector: A Performance Analysis

As the grid becomes smarter, the need to accurately detect, predict, and classify waveform phenomena is growing. When it comes to detecting high-frequency behaviors, i.e. transients, it is especially important to employ an event detection system that is able to accurately uncover these types of disturbances that would otherwise be lost with traditional hardware. In this paper, we first present the energy detector; a waveform event detection system that adaptively monitors a signal's energy and picks out high-frequency events that deviate from the nominal state. Secondly, we evaluate the performance of this detector against waveform data that have been corrupted by sensor irregularities. Using Oak Ridge National Laboratory's sensor testbed, we are able to show the results of the detector's performance against events that have been corrupted by three distinct sensor types, and examine how these results change with multiple trials. The results show excellent performance when detecting the beginning of an anomalous event with an average of less than 1% error.

Ekti, Ali Riza↗

Basic Energy Sciences Roundtable: Foundational Science to Accelerate Nuclear Energy Innovation

Energy security, availability, and reliability are among the greatest challenges facing the nation and the planet. An abundant potential source of energy resides in the fundamental atomic building blocks of the universe in the form of nuclear fission and fusion reactions. In fact, energy from nuclear fission currently provides the majority of the world’s zero-carbon electricity, and future fusion energy systems offer great promise; carbon-free nuclear energy technologies can be key to the world’s decarbonized energy future. Although contemporary fission systems use well-established technologies to supply safe and efficient baseload power, they could be more fuel efficient and less costly. Moving beyond massive light-water fission reactors to a variety of advanced nuclear systems—which will vary in size and operate in extremes of temperature, corrosivity, and other parameters—will place stringent conditions on materials and chemical systems. New demands will be placed on the coolants and solvents, the materials, and the monitoring tools used in these reactors. Fusion-based nuclear energy will require superior materials to withstand extremely high temperatures, plasma exposure, radiation damage, and implanted gases. The advantages associated with these new fission and fusion technologies will be realized only through continued advancements in the fundamental science underpinning our knowledge of the physics and chemistry of nuclear systems gained via improved experimental and computational methods. In July 2022, the U.S. Department of Energy’s Office of Basic Energy Sciences—in coordination with the Offices of Nuclear Energy, Fusion Energy Sciences, and Advanced Scientific Computing Research—held a virtual roundtable titled “Foundational Science to Accelerate Nuclear Energy Innovation” to discuss the scientific and technical barriers for advanced nuclear energy systems. Five priority research opportunities were identified to address these scientific and technical challenges and to accelerate progress toward the realization of next-generation fusion and fission energy systems. The foundational science gaps inhibiting the advancement of nuclear energy technologies are identified and tackled in five priority research opportunities. These opportunities pave the way to accelerate the development and ultimately the adoption of new nuclear energy systems. They include the fundamental aspects of ion-electron interactions; novel properties of next-generation coolants and solvents; interfacial dynamics, not only in solids, but in other aspects of nuclear reactors; novel operando and in situ monitoring and sensing; and artificial intelligence to accelerate condensed phases discovery. Building on the foundation established by previous Basic Energy Sciences workshops, these opportunities encompass recent advances in fundamental knowledge and focus on the experimental and computational methods needed to resolve major technical challenges for nuclear energy technologies. Through developing fundamental scientific insight as well as pushing the frontiers of modeling complex systems and probing the operation of materials and chemical systems in extreme environments, research motivated by the priorities identified here will further develop the promise, potential, and utilization of nuclear energy for a clean energy future.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radio Frequency Field Programable Gate Array Implementation of Reflectometry Cable Monitoring

PNNL has developed an innovative cable testing system that leverages the Xilinx RF System-on-Chip (RFSoC) technology to create a more flexible and capable measurement tool than traditional approaches. The architecture is designed on the ZCU111 development board and takes advantage of the high-speed digital to analog converters (DAC) and analog to digital converters (ADC) to generate and capture digitally synthesized waveforms. The platform allows engineers to easily adjust power, frequency, duration and modulation on the fly rather than being locked into fixed hardware configurations

Tedeschi, Jonathan [Pacific Northwest National Lab↗

Application of Advanced Metering Infrastructure Data to Advanced Utility System Operations: Cooperative Research and Development, CRADA Number CRD-17-00712 (Final Report)

The primary objective of the proposed project is to evaluate the capabilities of Advanced Metering Infrastructure (AMI) based controls for grid operations. This includes monitoring and control at the secondary transformer level using existing AMI infrastructure. In addition, some of the challenges of using a model-less control will also be identified. The lessons learned will be disseminated to other utilities around the country through peer-reviewed publications with the consent of SDG&E. The scope of the work includes using data from SDG&E's existing AMI infrastructure and working with third party vendors selected by SDG&E. The grid edge monitoring systems and controls provided by the selected vendors will perform grid operations using AMI data. The National Renewable Energy Laboratory (NREL) will perform a software and controller-based evaluation of the grid edge controller, intelligent devices and sensors, at the Energy System Integration Facility (ESIF) laboratory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Energy Resources Cybersecurity Framework & Risk Manager

Distributed Energy Resource Cybersecurity Framework (DER-CF) provides a holistic assessment for evaluating the cybersecurity posture of DER systems - filling an important gap that expands upon existing cybersecurity frameworks for more modern energy systems. The DER-CF is available as a written framework and an interactive Web tool. Distributed Energy Resource Risk Manager (DER-RM) process adheres closely to NIST's seven risk management steps: prepare, categorize, select, implement, assess, monitor, and authorize. This added feature is independent of the DER-CF's existing self-assessment and allows managers to focus on the RMF process.

cybersecurity↗

First application of a digital mirror Langmuir probe for real-time plasma diagnosis

We report for the first time, a digital Mirror Langmuir Probe (MLP) has successfully sampled plasma temperature, ion saturation current, and floating potential together on a single probe tip in real time in a radio-frequency driven helicon linear plasma device. This is accomplished by feedback control of the bias sweep to ensure a good fit to I–V characteristics with a high frequency, high power digital amplifier, and field-programmable gate array controller. Measurements taken by the MLP were validated by a low speed I–V characteristic manually collected during static plasma conditions. Plasma fluctuations, induced by varying the axial magnetic field($\widetilde{f}$ = 10 Hz), were also successfully monitored with the MLP. Further refinement of the digital MLP pushes it toward a turn-key system that minimizes the time to deployment and lessens the learning curve, positioning the digital MLP as a capable diagnostic for the study of low radio-frequency plasma physics. These demonstrations bolster confidence in fielding such digital MLP diagnostics in magnetic confinement experiments with high spatial and adequate temporal resolution, such as edge plasma, scrape-off layer, and divertor probes.

47 OTHER INSTRUMENTATION↗

In-Water Data Acquisition Tool Supports Four Marine Energy Projects

The NREL-developed Modular Ocean Data Acquisition (MODAQ) system is built from open-source hardware and software. The tool can both collect and store data and even share curated information through the cloud. Marine energy developers can work with NREL's engineers to design their own customized MODAQ and capture high-quality field data to help monitor and improve their technology designs. For example, users could assess how much power their device produces at sea, analyze the durability of a specific device component, or even control their device from a desk halfway around the world.

data acquisition↗

Failure diagnosis and trend‐based performance losses routines for the detection and classification of incidents in large‐scale photovoltaic systems

Abstract Fault detection and classification in photovoltaic (PV) systems through real‐time monitoring is a fundamental task that ensures quality of operation and significantly improves the performance and reliability of operating systems. Different statistical and comparative approaches have already been proposed in the literature for fault detection; however, accurate classification of fault and loss incidents based on PV performance time series remains a key challenge. Failure diagnosis and trend‐based performance loss routines were developed in this work for detecting PV underperformance and accurately identifying the different fault types and loss mechanisms. The proposed routines focus mainly on the differentiation of failures (e.g., inverter faults) from irreversible (e.g., degradation) and reversible (e.g., snow and soiling) performance loss factors based on statistical analysis. The proposed routines were benchmarked using historical inverter data obtained from a 1.8 MWp PV power plant. The results demonstrated the effectiveness of the routines for detecting failures and loss mechanisms and the capability of the pipeline for distinguishing underperformance issues using anomaly detection and change‐point (CP) models. Finally, a CP model was used to extract significant changes in time series data, to detect soiling and cleaning events and to estimate both the performance loss and degradation rates of fielded PV systems.

14 SOLAR ENERGY↗

Advanced Microstructured BaTiO 3 -Embedded PVDF–HFP/PEO Film for Enhanced Triboelectric Interface in Self-Sufficient Energy Generation and Sensing

The global reliance on fossil fuels and natural gas has largely dominated the energy production field, but due to finite resource depletion and escalating greenhouse gas emissions, the immediate exploration of sustainable energy alternatives to mitigate climate change and ensure resource security has been a major concern. There has been extensive research into other more renewable methods of energy production, such as wind and hydropower. Of these current energy generation types, there are many areas of untapped potential from the mechanical movements generated ambiently not only in the large scale of power generation but also on a smaller scale. The piezoelectric and triboelectric effects are phenomena where these ambient mechanical movements can generate electrical energy. Developing a hybrid system that leverages both mechanical stress and surface charges presents an ideal opportunity to exploit these untapped energy sources. Producing a hybrid PVDF–HFP/PEO film with perovskite BaTiO 3 (BTO) enables ambient power harvesting from both mechanical movement and surface charge. The optimized cell produced a potential of up to 15 V and a current of 200 nA with a 68 kΩ resistor, a substantial increase from a base system with an average of 2.1 V and 40 nA. These hybrid TENGs offer significant potential for energy harvesting in small-scale applications, such as health monitoring devices and indicators in electric circuits.

Ybarra, Rigobert [University of Texas Rio Grande V↗

Temperature and Dynamic Strain Measurements Using a Single SAWR Sensor

Dynamic strain sensing is relevant in numerous applications involving structural health monitoring, condition-based maintenance, operation efficiency preservation, and work environment safety. These sensors are particularly critical for high-temperature (HT) harsh-environment (HE) industries such as aerospace, automotive, power plants, and advanced manufacturing. In HT/HE, sensor implementation and measurement present challenges such as maintaining sensor stability, accounting for temperature cross-sensitivity, providing HT attachment, and packaging of the sensors and system. Surface acoustic wave resonator (SAWR) sensors can address these needs and offer additional benefits such as compact size and wireless interrogation capability. The SAWR sensitivity to dynamic strain is temperature dependent, making it necessary to measure the sensor temperature in order to use the correct dynamic strain calibration curve. In this work, a method for determining the temperature, dynamic strain magnitude, and dynamic strain spectral components using a single SAWR sensor is presented. Here, the established technique for determining operational temperature and dynamic strain magnitude/spectral components using only one SAWR simplifies the sensor measurement system, thus being very attractive for HT /HE applications.

47 OTHER INSTRUMENTATION↗

Review—Thermal Safety Management in Li-Ion Batteries: Current Issues and Perspectives

Approaches for thermal management of lithium-ion (Li-ion) batteries do not always keep pace with advances in energy storage and power delivering capabilities. Root-cause analysis and empirical evidence indicate that thermal runaway (TR) in cells and cell-to-cell thermal propagation are due to adverse changes in physical and chemical characteristics internal to the cell. However, industry widely uses battery management systems (BMS) originally designed for aqueous-based batteries to manage Li-ion batteries. Even the "best" BMS that monitor both voltage and outside-surface temperature of each cell are not capable of preventing TR or TR propagation, because voltage and surface-mounted temperature sensors do not track fast-emerging adverse events inside a cell. Most BMS typically include a few thermistors mounted on select cells to monitor their surface temperature. Technology to track intra-cell changes that are TR precursors is becoming available. Simultaneously, the complex pathways resulting in cell-to-cell TR propagation are being successfully modelled and mapped. Innovative solutions to prevent TR and thermal propagation are being advanced. These include modern BMS for rapid monitoring the internal health of each individual cell and physical as well as chemical methods to reduce the deleterious effects of rapid cell-to-cell heat and material transport in case of TR.

25 ENERGY STORAGE↗

Energy Improvements of Fire Station 71

Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.

14 SOLAR ENERGY↗

First application of a digital mirror Langmuir probe for real-time plasma diagnosis

For the first time, a digital Mirror Langmuir probe (MLP) has successfully sampled plasma temperature, ion saturation current, and floating potential together on a single probe tip in real time in a radio-frequency driven helicon linear plasma device. This is accomplished by feedback control of the bias sweep to ensure a good fit to I-V characteristics with a high frequency, high power digital amplifier and field-programmable gate array (FPGA) controller. Measurements taken by the MLP were validated by a low speed I-V characteristic manually collected during static plasma conditions. Plasma fluctuations, induced by varying the axial magnetic field (f̃ = 10 Hz), were also successfully monitored with the MLP. Further refinement of the digital MLP pushes it towards a turn-key system that minimizes the time to deployment and lessens the learning curve, positioning the digital MLP as a capable diagnostic for the study of low radio-frequency plasma physics. These demonstrations bolster confidence in fielding such digital MLP diagnostics in magnetic confinement experiments with high spatial and adequate temporal resolution such as edge plasma, scrape-off layer, and divertor probes.