Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power balance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

A Novel Voltage Balancing Control With dv/dt Reduction for 10-kV SiC MOSFET-Based Medium Voltage Modular Multilevel Converter

Using high voltage (HV) silicon carbide (SiC) power semiconductors in a modular multilevel converter (MMC) is promising because it results in fewer submodules and lower switching loss compared to conventional Si based solutions. The nearest level pulsewidth modulation (NL-PWM) is commonly used in the MMC for medium voltage applications. However, with the NL-PWM and existing voltage balancing control, there are many submodules that switch their modes in a control cycle, resulting in a high dv/dt during the deadtime of the power semiconductor, which could be multiple times of the dv/dt of the single device. This poses great challenges on the noise immunity and insulation design in the MMC using HV SiC devices, which have very fast switching speed. A novel voltage balancing control, which ensures only two submodules switch their modes in a control cycle, is proposed in this article, limiting the maximum dv/dt to the dv/dt of a single power semiconductor and also maintaining the voltage balance performance. Furthermore, the proposed voltage balancing control is experimentally validated in a 10-kV SiC mosfet based MMC with four submodules per arm.

42 ENGINEERING↗

What Is the Value of Alternative Methods for Estimating Ramping Needs?

Power system operators procure and deploy flexibility reserves or ramping products to address balancing needs caused by uncertainty and variability of load and generation. Existing methods estimate ramping needs using calendar information and historical forecast errors. Novel methods investigate if real-time weather information could inform ramping and other balancing requirements. This paper compares estimation methods for ramping requirements in theory and practice. The theoretical framework indicates when an alternative method could yield improved economic or reliability performance than existing methods by requiring lower or higher levels of ramping products. Preliminary simulations on a 118-bus test system for 4 days in May 2019 illustrate how system performance improves or deteriorates when ramping requirements are weather-informed (alternative) instead of calendar-based (baseline). Preliminary results suggest high variability in change of performance and underline the impact of additional factors, such as system conditions, on the realized performance change.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Inverter Controls for Smooth Transition Operation and Voltage Balancing of Networked Microgrids

With increasing penetrations of distributed energy resources (DERs), researchers have extensively studied the formation and networking of microgrids to improve reliability during distribution system outages. However, these operations might require DERs in the microgrids to switch between grid-following (GFL) and grid-forming (GFM) modes of operation. A smooth transition between the operation modes should be ensured to have a stable system operation and to avoid nuisance tripping. Additionally, as we network microgrids, inverter control schemes with voltage-balancing controls are needed for unbalanced distribution networks. This paper presents the design of a GFM and GFL capable inverter control scheme for reliable operation in networked microgrids with mechanisms for 1) smooth transition between the GFL and GFM modes, and 2) negative sequence voltage control for voltage balancing. Using electromagnetic transient (EMT) simulations, the control scheme is first tested on a simple two-source power system using a digital real-time simulator. Next, a real-world distribution feeder with unbalanced loading and multiple DERs is used to demonstrate stable operation during the networking of microgrids with voltage balance support.

distributed energy resources↗

Multijunction Solar Cell Development and Production at Spectrolab

Development of multijunction space solar cells is much like that for any high technology product. New products face two major pressures from the market: improving performance while maintaining heritage. This duality of purpose is not new and has been represented since ancient times by the Roman god Janus.[1] This deity was typically represented as two faces on a single head: one facing forward and the other to the rear. The image of Janus has been used as symbolism for many combined forces of dual purpose, such as the balance in life between beginnings and endings, or between art and science. For our purposes, Janus represents our design philosophy balance between looking to the future for improvement while simultaneously blending past heritage. In the space photovoltaics industry there are good reasons for both purposes. Looking to the past, a product must have a space flight heritage to gain widespread use. The main reason being that this is an unforgiving business. Spacecraft are expensive to build, launch and operate. Typically once a satellite is launched, in-field service for a power systems problem is near impossible.[2Balanced with this is looking forward. New missions typically require more power than previous programs or attempt new objectives such as a new orbit. And there is always the cost pressure for both the satellite itself as well as the launch costs. Both of which push solar technology to improve power density at a lower cost. The consequence of this balance in a high-risk environment is that space PV develops as a series of infrequent large technology steps or generational changes interspersed with more frequent small technology steps or evolutionary changes. Figure 1 gives a bit of clarification on this point. It depicts the historical progress in space solar cells tracked by efficiency against first launch date for most major products introduced by Spectrolab. The first generation is the Si-based technology reaching a peak values near 15% AM0 (herein denoted for max. power, AM0, 1.353 W/cm2, 28 C). The GaAs single junction device generation supplanted this technology with first flight of GaAs on GaAs substrate in 1982.[3] More recently this generation has been supplanted by the multijunction solar cell GaInP/GaAs/Ge generation. The first launch of a commercial satellite powered by multijunction technology was in 1997 (Hughes HS 601HP) using solar arrays based on Spectrolab s dual junction (DJ) cells. The cells at that time were an impressive 21.5% efficient at beginning-of-life (BOL).[4] Eight years later, the multijunction device has evolved through several versions. The incorporation of an active Ge subcell formed the Triple Junction (TJ) product line at 25.1% efficient, on orbit since November 2001. The evolution of the TJ into the Improved Triple Junction (ITJ) at 26.8% efficient has been on orbit since June of 2002.[5]

Fetzer, Chris↗

Seismic Isolation of Major Advanced Reactor Systems for Economic Improvement and Safety Assurance

Advanced reactor concepts currently under development in the United States [e.g., the High-Temperature Gas Reactor (HTGR) of X-Energy and the Molten Chloride Fast Reactor (MCFR) of TerraPower] are striving to improve the economics of nuclear power primarily by using passively and ‘walk-away’ safe technologies in the reactor. The recently published report, ‘Future of Nuclear Energy in a Carbon-Constrained World’ by the Massachusetts Institute of Technology Energy Institute (MIT EI) has shown that a significant contributor to the capital cost of NPPs is the ‘civil works’ i.e., the construction of the balance of plant (BoP: all SSCs except those involved in power generation, e.g., reactor vessel) such as the buildings, containment dome, foundation, etc., which amount to almost half of the overnight capital cost. The report suggests that using advanced construction technologies such as seismic isolation and high-performance concrete to significantly reduce the capital costs of advanced reactors. This report demonstrates the application of two cost-cutting solutions on advanced reactor designs that are currently under development. These solutions include, (1) seismic base isolation, and (2) risk- and cost-based seismic design optimization including seismic isolation of individual components.

42 ENGINEERING↗

MPC-based double-layer real-time conditional cSelf-restoration for interconnected microgrids

In this report, we propose a novel model predictive control(MPC)-based real-time conditional self-restoration energy management system (CSR-EMS) for interconnected microgrids (IMGs) integrated with renewable energy sources (RESs) and energy storage systems (ESSs). Superior to the existing IMG self-restoration methods, the “conditionality” of the proposed CSR-EMS can economically realize self-restoration and grid-assisted restoration during energy deficiency or faults, in both islanded and grid-connected modes. Cost minimization is implemented as the objective function to judge in real-time which restoration mode is economically preferred. The proposed CSR-EMS comprises two layers–the lower layer operates locally to eliminate electricity fluctuations created by RESs and ensure economic effectiveness within an MG, whereas the upper layer oversees the real-time operational status of the IMG system and determines power exchange among microgrids (MGs) during abnormalities. In detail, when a microgrid inside the IMG system experiences an energy deficiency, the CSR-EMS, on an MPC basis, intelligently optimizes power production from each dispatchable distributed generator (DG), ESS, power imported from the main grid, and power exchange among the IMGs to maintain the demand–supply balance, while considering system recovery cost, state of charge (SoC) of ESSs and operation modes of the IMGs (i.e., grid-connected or islanded mode). Simulation results and comparisons with existing IMG self-healing EMSs demonstrate the economic efficacy of the proposed CSR-EMS strategy during normal and abnormal operations, which can be used as an energy control framework for modern power systems with multiple interconnected microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Power MPD Thruster Development at the NASA Glenn Research Center

Propulsion requirements for large platform orbit raising, cargo and piloted planetary missions, and robotic deep space exploration have rekindled interest in the development and deployment of high power electromagnetic thrusters. Magnetoplasmadynamic (MPD) thrusters can effectively process megawatts of power over a broad range of specific impulse values to meet these diverse in-space propulsion requirements. As NASA's lead center for electric propulsion, the Glenn Research Center has established an MW-class pulsed thruster test facility and is refurbishing a high-power steady-state facility to design, build, and test efficient gas-fed MPD thrusters. A complimentary numerical modeling effort based on the robust MACH2 code provides a well-balanced program of numerical analysis and experimental validation leading to improved high power MPD thruster performance. This paper reviews the current and planned experimental facilities and numerical modeling capabilities at the Glenn Research Center and outlines program plans for the development of new, efficient high power MPD thrusters.

LaPointe, Michael R.↗

A Distributed Control Architecture for Cascaded H-Bridge Converter with Integrated Battery Energy Storage

Cascaded H-bridge topology has been used in grid-tied converters for battery energy storage system due to its modular structure. To fully utilize the converter’s modularity, this paper proposes a hierarchical distributed control architecture that consists of primary control, secondary control and battery state of charge (SOC) balancing control. Primary control ensures accurate current tracking while a distributed secondary control based on consensus algorithm is presented to regulate power sharing among modules and is proved to be stable theoretically. Here, a distributed SOC balancing control is further introduced to improve energy efficiency of battery energy storage system. Finally, the hierarchical distributed control strategy is implemented using hardware controllers and a software platform. Besides, a carrier phase shift control is also implemented to achieve multilevel output voltage and harmonic reduction. The experimental results demonstrate the performance of the proposed control scheme effectively.

25 ENERGY STORAGE↗

Fuel cells for single-aisle regional aircraft: System configuration, performance and cost

A hydrogen fuel cell propelled electric aircraft can compete with incumbent turbofan technologies for single-aisle regional aircraft by coupling design of stack, air handling, thermal management, propulsion, and airframe to optimize performance. The stack operates at 95°C to facilitate heat rejection during take-off and below 75°C during cruise to extend lifetime and is oversized to satisfy power requirements at end of life. A multi-stage turbocompressor with a compression ratio >10 is selected to reach high stack power density at 11,300-m cruise altitude. The propulsion system is configured to accommodate air handling within the core duct, an inclined heat exchanger in the outer duct to limit the nacelle size, and variable area nozzles to independently control mass flows through the core and bypass ducts. The airframe is modified for maximum lift coefficient and longer balanced field length for dramatically reduced thrust during take-off, and the fuselage is stretched by 20% to store liquid hydrogen (LH 2 ). Modularization of power systems promotes safety in one engine inoperative scenarios and allows reaching specific power metrics for stack, balance-of-plant and fuel cell system (FCS), necessary for acceptable take-off weight. In conclusion, cost parity requires increase in FCS lifetime, LH 2 cost reduction, and improved FCS specific power.

Catalyst durability↗

The spherical tokamak advanced reactor (STAR) fusion power plant design

Scientific and technical advancements have been made that improve fusion’s prospects to provide a new energy source, showing enhanced plasma confinement conditions with plasma temperatures reaching or exceeding 100 million degrees. Overshadowing this progress is the challenge involved in developing an economically viable fusion power plant design. Many proposed next-step DEMO and pilot plant designs are extensions of existing physics-focused experimental devices defined to understand and control plasma operations to achieve and sustain a fusion reaction. Transitioning scientific and technical advancements into a functional power plant requires a dedicated focus on architectural designs that integrate diverse technologies, while optimizing physics conditions, with a focus on economic viability. This holistic approach is essential in turning the promise of fusion energy into a reality. The Spherical Tokamak Advanced Reactor (STAR) is a fusion power plant conceptual design with the architectural focus that strives to balance physics, engineering, and cost considerations. In conclusion, it has been set up to introduce relevant physics, engineering and concept features that an intermediate pilot plant might follow, with the goal of meeting system performances and economic requirements that lead to a commercially competitive fusion power plant.

Blanket segmentation↗

Analysing a multi‐stage cyber threat and its impact on the power system

Abstract Electric power systems are composed of physical and cyber sub‐systems. The sub‐systems depend on each other. If the cyber sub‐system is compromised by a cyber threat, what is the impact on the physical system? This paper presents a case study that shows the steps of a multi‐stage cyber threat involving a database injection attack, and what happens to the power system if this threat is not detected in its early stages. The threat first affects one utility but it can spread to the balancing authority, which is responsible for keeping the voltage and frequency stable in the power grid. During the cyber threat, the authors also show defence tools, such as a cyber‐physical data fusion tool that displays and analyses power and cyber telemetry.

Al Homoud, Leen [Texas A&amp,M University College ↗

Net-Zero Carbon Microgrids

The microgrid concept has been effective in creating aggregations of distributed energy resources—generation, storage and loads—for resiliency, in the form of energy security. The success of microgrids in bringing energy security to a wide range of customers—from individual residences to commercial and industrial installations to military bases—has been exemplified during power disruptions and extended outages due to extreme weather events, cybersecurity attacks, and equipment failures. Now microgrids have an opportunity to meet the challenges of climate change and contribute to a carbon-free power delivery system. The transition to net-zero starts within microgrids themselves. In fact, today’s microgrids are largely dominated by generators using fossil fuels, natural gas and diesel, with high greenhouse gas emissions. In short, the transition to net-zero means replacing fossil fueled generators with renewable generation in microgrids. This transition is extended by including new dispatchable generation technologies that are 100% carbon-free and that offer additional advantage of a more-dependable and sustainable source of energy and power. Basically, the decarbonization of microgrids requires three elements: 1) maximizing generation from renewable energy resources, 2) management of storage and flexible loads to balance the variability and intermittency of renewable energy resources, and 3) introducing new clean power sources, including hydrogen-based generation and small modular reactors. This report affirms a need for specific focus by governmental agencies at national, regional, and local levels to establish technology, policy, and investment in this area. The intention of the Net-Zero Microgrid (NZM) Program is to inform these constituencies with cross-cutting research and tools for the reduction of GHG in microgrids – to net-zero in the near term eventually to zero in the longer term. The NZM Program is committed to achieving decarbonization for resiliency and for providing clean energy at the local or distribution level, from remote communities to underserved communities, and large industrial and military facilities. The NZM Planning and Design Platform is a core tool to be developed as an early deliverable of the NZM Program because only a fully integrated microgrid-design approach will ensure maximum carbon reduction in energy production.

13 HYDRO ENERGY↗

Using Liquid Natural Gas Fuel to Cryogenically Cool and Enhance a Hybrid Electric Aircraft Power System

A previous system study identified significant increases in range and number of urban air mobility (UAM) missions by replacing the all battery power system of a notional UAM vehicle with an advanced diesel hybrid using conventional diesel or liquid natural gas (LNG) fuels (at constant vehicle design gross weight). Some benefits were realized using the LNG's cryogenic properties to reduce some electrical component losses and cooling requirements. Significant questions were raised concerning volume and thermal management considerations for all studied systems. The notional, baseline vehicle was a hybrid helicopter / airplane design capable of vertical take-off and landing (VTOL), balancing high cruise efficiency with reasonable hover capability. A subsequent power system assessment using the same notional vehicle and mission was performed that identified increased volume and power requirements for the active cooling required. The cooling airflow could also generate additional drag on the vehicle during operation. For the notional vehicle studied, the additional volume identified by the subsequent study would not affect vehicle mold line and therefore drag. However, the additional drag from cooling airflow and the power to circulate it as needed would impact power system and vehicle mission performance. Vehicle and mission models were updated and rerun. Updated results still indicated significant benefits in range and number of UAM missions, but reduced the benefit by 12-15%. Hold time for the hybrid systems also generally increased a few minutes because of reduced power available for charging from the power for required cooling flows. Vehicle weights, thermal loads, and cooling airflows from the updated analyses were similar to previous results.

systems analysis↗

Transformational Solid Oxide Fuel Cell (SOFC) Technology

This project was conducted under the Co-operative Agreement No. DE-FE0027584 with the US Department Energy to developed advanced Solid Oxide Fuel Cell (SOFC) Technologies. The overall objective of this project was to advance SOFC technology at the cell and stack level to enhance cell robustness and durability, increase performance, and reduce balance-of-plant (BOP) requirements. By reducing system complexity combined with the increases in power density and efficiency, the ultimate goal of the project was to increased reliability and to reduce capital and operating costs of installed systems. The project was focused on pathways that will reduce the cost of the SOFC cell and stack, including the following areas: Robust, redox tolerant cell technology Lower cost cell manufacturing through advances in cell design, which will reduce the amount of material, energy and time used in the fabrication of SOFCs High performance, low temperature electrolyte based on improvement of established materials Innovative SOFC stack architecture which truly integrates Balance of Plant functionality into the stack level design Thermal management of the fuel cell stack for increased durability and expanded window of operation Novel stack design amenable for use in sub-MW to multi-MW-scale power plants and having low replacement cost The incorporation of balance-of-plant (BOP) equipment into the stack platform increased the economic viability of smaller scale systems. The project objectives were met by a multi-prong approach, including new cell design complemented with modifications to existing cell technology, as well as a new stack design incorporating components typically included in the BOP, such as heat exchangers, oxidizer, fuel reformers, and recycle systems. The project culminated with demonstration of a stack test validating the viability of the cell and stack improvements. A cost model was also developed to estimate costs for the advanced stack technology at high volume manufacturing levels. The net outcome of the project is SOFC cell and stack technology with costs significantly below current DOE targets without compromising and, in some cases, improving on the performance and degradation rate demonstrated with the current state-of-the-art stack design. The results of this project advanced the reliability, robustness, and endurance of low-cost SOFC technology that ultimately are ready to be deployed in coal power systems with greater than 60 percent efficiency (based on higher heating value of fuel) and the capability for ≥97% CO 2 capture at a cost-of-electricity that is approximately 40 percent below presently available Integrated Gasification Combined Cycle systems.

03 NATURAL GAS↗

Scaleup and Site-Specific Engineering Design for Global Thermostat Direct Air Capture Technology

The overall goal of the project is completion of an initial design of a commercial-scale, Carbon Capture, Utilization, and Storage Direct Air Capture (CCUS-DAC) plant design at three different sites that captures a net of at least 100,000 tonnes per year (TPY) carbon dioxide (CO 2 ) from the atmosphere and considers compression and conditioning of the captured CO 2 for purpose of pipeline transportation to different geological formation sites for deep well injection and underground storage. In addition to the leading system consisting of a scaled-up Global Thermostat DAC unit, overall plant design includes a combined Heat and Power (CHP) unit integrated with a conventional liquid amine-based carbon capture system (90% capture) and compression facilities. These are considered balance of plant (BOP) systems and are required to provide low carbon-intensity steam and power to the DAC process. A second approach involving provision of DAC units modified to directly capture emissions from the CHP unit was initially assessed as an alternative and it was determined to be less mature than considered approach and not included in the scaled-up plant design efforts. Three geographically diverse continental United States locations were selected to better understand the effect of local/regional ambient conditions on scaled-up DAC system performance and project costs: Bucks, Alabama (hot wet climate), Odessa, Texas (dry hot climate), and Goose Creek, Illinois (mid continental climate). The team focused on initial engineering design activities, including the development of project design criteria, initiation of site-specific studies and investigations, completion of DAC system process and equipment design, and definition of balance of plant (BOP) engineering. The purpose of the activities were to develop Technoeconomic Analysis (TEA), Life-Cycle Analysis (LCA), and Environmental, Health, and Safety (EH&S) analysis, and Business Case Analysis (BCA) to validate that the project engineering and scale-up plans of the DAC systems, at each of the three distinct case studies considered, are technically, economically, and environmentally feasible for commercial-scale operation.

20 FOSSIL-FUELED POWER PLANTS↗

TunIO: An AI-powered Framework for Optimizing HPC I/O

I/O operations are a known performance bottleneck of HPC applications. To achieve good performance, users often employ an iterative multistage tuning process to find an optimal I/O stack configuration. However, an I/O stack contains multiple layers, such as high-level I/O libraries, I/O middleware, and parallel file systems, and each layer has many parameters. These parameters and layers are entangled and influenced by each other. The tuning process is time-consuming and complex. In this work, we present TunIO, an AI-powered I/O tuning framework that implements several techniques to balance the tuning cost and performance gain, including tuning the high-impact parameters first. Furthermore, TunIO analyzes the application source code to extract its I/O kernel while retaining all statements necessary to perform I/O. It utilizes a smart selection of high-impact configuration parameters of the given tuning objective. Finally, it uses a novel Reinforcement Learning (RL)-driven early stopping mechanism to balance the cost and performance gain. Experimental results show that TunIO leads to a reduction of up to ≈73% in tuning time while achieving the same performance gain when compared to H5Tuner. It achieves a significant performance gain/cost of 208.4 MBps/min (I/O bandwidth for each minute spent in tuning) over existing approaches under our testing.

Rajesh, Neeraj↗

Comparative Thermal Performance of Downdraft and Updraft Forced Convection in a Representative 3x3 PWR Fuel Assembly

A plethora of theoretical, numerical, and experimental investigations have relied on updraft forced convection of operating fuel assemblies for light water-cooled fuel assemblies. The inertial scales of turbulence in updraft flow through PWR fuel assemblies are primarily influenced by upstream mixing patterns within the lower plenum and consequent acceleration of flow through the lower core and support plates into the bottom nozzles. In secondary heat transfer applications such as steam generation, recuperation and economization, downdraft flow is utilized to retrieve maximal sensible heat from the primary coolant. Sub-channel volumes aligned vertically could also benefit from force of gravity in developing turbulent flows. A large reduction in pumping power, associated cost of operation and maintenance, and improved balance of plant is suggested to be possible through downdraft forced convection in PWR-type reactors. This article explores the impact of downdraft forced convection within the well-studied 3x3 sub-channel within a range of 20 hydraulic diameters across a representative intermediate flow mixing grid. A range of inflow Reynolds number from 10,000 to 60,000 is simulated over a range of equivalent heat loads of 20% to 100% spanning 20 hydraulic diameters. The fuel rods are represented in true geometric detail, and a constant-value heat profile is assumed for the investigation. At each inflow condition, the turbulence intensity, peak velocity, local heat transfer coefficient, peak wall heat flux, and peak wall temperature are collected across the sub-channel and compared with an updraft configuration evaluated at the same conditions.

Rao, Vivek↗

Benchmark Exercise for the Control Rod Swelling Evaluation

The VTR core has six reactivity control assemblies and three safety assemblies. The control assemblies or primary control rods are adjusted during the normal operation to balance the core reactivity and to control the reactor power. A typical control assembly radial layout is presented in Figure 1. The figure shows the swelled absorber (B 4 C) rod. Initially, helium gas fills the gap between the pin and the cladding before irradiation swelling takes place. For VTR, HT9 steel was selected as the cladding and duct material. The main neutron absorbing material used in the VTR is B 4 C. When residing in the core, the neutronics, thermophysical, and mechanical properties of the materials used in a control assembly will degrade due to accumulated neutron damage. Material degradation limits how long a control assembly can reside in the core. Many phenomena affect the control assembly lifetime, such as the loss of reactivity worth due to B 4 C depletion, the mechanical interaction of the absorber rod and the cladding due to B 4 C swelling, the helium gas buildup in the pin due to B-10 capture, etc. B 4 C swelling, which causes closure of the gap between the absorber rod and the cladding, is usually considered as the main limiting factor from past experience. An initial study was conducted at PNNL to evaluate the irradiation behavior of a VTR control assembly. The evaluation was performed using the CNRD2 code that was initially developed for the FFTF. The study also included an assessment of the VTR control assembly and focused on a 61-pin control assembly design, which is different from that used (37-pin design) in the core design study. The study conducted by PNNL was reviewed independently by ANL. A Python script referred to as the Control Assembly Evaluation Script (CAES) was developed for the independent review and additional assessment of 37-pin control assembly design. The script has focused on the assessment of the absorber rod swelling for its importance in determining the control assembly lifetime. CAES uses geometry, neutronics, materials data as input to predict the swelling of the absorber rod during its residence in the reactor core. The results from CAES showed some non-negligible differences against the PNNL results. Some of the differences can be attributed to the different interpretation of the control rod assembly dimensions. To resolve this issue, a benchmark exercise was proposed. The benchmark specification was developed by PNNL. The benchmark exercise was performed independently at PNNL and ANL using different codes/scripts (CRND2 and CAES). This memo documents the results calculated using the different codes. However, this report is limited to presenting the results obtained. Further investigation of the cause of the observed difference will be performed as part of future activities, pending continuation of the VTR program.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗