Resonance Ionization Spectroscopy Experiment at Facility for Rare Isotope Beams

This manuscript reports on the commissioning of the Resonance Ionization Spectroscopy Experiment (RISE) at the BEam COoler and LAser spectroscopy (BECOLA) facility at Facility for Rare Isotope Beams (FRIB). The instrument implements the collinear resonance ionization spectroscopy technique for sensitive measurements of isotope shifts and hyperfine structure of short-lived isotopes produced at FRIB. The existing BECOLA beamline was extended to integrate an electrostatic ion-beam bender and an ion detector at ultrahigh vacuum. An injection-seeded titanium-sapphire laser and a multiharmonic pulsed neodymium-doped yttrium aluminum garnet laser were installed to perform resonant excitation and selective ionization. Commissioning tests were performed to demonstrate the capabilities of the instrument by measuring the hyperfine structure of stable 27 Al produced in an offline ion source. The RISE instrument is ready and operational for future studies of short-lived isotopes at FRIB.

Atomic spectra↗

Statistical Modeling of Peak Accelerating Gradients in LCLS-II and LCLS-II-HE

In this report, we study the vertical test gradient performance and the gradient degradation between vertical test and cryomodule test for the 1.3 GHz LCLS-II cavities. We develop a model of peak gradient statistics, and use our understanding of the LCLS-II results and the changes implemented for LCLS-II-HE to estimate the expected gradient statistics for the new machine. Finally, we lay out a plan to ensure that the LCLS-II-HE cryomodule gradient specifications are met while minimizing cavity disqualification by introducing a variable acceptance threshold for the accelerating gradient.

43 PARTICLE ACCELERATORS↗

Empirical Validation of Multi-Zone HVAC System Model: Evaluation of Existing Infiltration Models used in Building Energy Simulation

Infiltration can have a significant impact on building loads. Studies have shown that infiltration can account for 15-40% of annual space conditioning needs in commercial buildings (Emmerich et al. 2019; Younes et al. 2012). The driving force of infiltration is the pressure difference across the building envelope caused by wind, the stack effect (known as buoyancy effect), and the operation of ventilation equipment. Wind pressure is governed by wind direction, speed, building shape, and other structures around the building. The stack effect is a function of the building height and air density differences of ambient air (Han, 2015). The effect of wind is dominant in low-rise residential buildings, and the stack effect is dominant in highrise buildings (ASHRAE 2017). In building energy simulation programs (e.g., EnergyPlus), various empirical infiltration models (e.g., the effective leakage area model, the flow coefficient model) are available to simulate infiltration rates. To help users in selecting a proper infiltration model for modeling of the two-story Flexible Research Platform (FRP), the team evaluates the existing infiltration models in EnergyPlus based on field measurements from the FRP. The blower door and tracer gas decay tests were performed in the FRP. The blower door test result was used to estimate input parameters required in the infiltration models. The actual infiltration rates were estimated with the tracer gas decay test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FY20 Status Report on Creep Rupture Testing to Support the Development of Alloy 709 Code Case

This report provides an update on the status of the creep rupture testing on the first commercial heat of Alloy 709 in support of the Alloy 709 Code Case development. A creep test laboratory has been set up at ANL that comprises of 15 indirectly loaded test frames capable of testing ASTM-size specimens of the commercial heat of Alloy 709. The systems are equipped with high temperature furnaces capable of operation up to 1000°C in an air environment. During FY18, uniaxial ASTM-sized creep specimens were fabricated from 9 Alloy 709 plates that were processed by AOD, ESR, and ESR-homogenized routes and subsequently solution annealed at 1050, 1100, and 1150°C, and creep-rupture tests were performed at 330MPa and 600°C. The test results led to the down selection of the ESR-1100°C condition to support the code case. In FY19, 15 creep-rupture tests of the ESR-1100°C material, requiring the use of Type K thermocouples, were initiated to support the 100,000-hour Code Case. 8 tests were completed in FY19. In FY20, 6 tests were completed at the time of writing this report. In addition, 1 more test were loaded in FY20, using Type S thermocouples, and was completed. This report presents the data from the completed tests in FY20 and also the microstructural characterization of the fractured specimens. The creep data enabled the preliminary analysis of the creep behavior of this material. The characterization showed that in brittle fractures, the pores were narrow and thin, and elongated in the direction perpendicular to the loading direction, while in ductile fractures, the pores were much rounder. Dense precipitates were observed in all the samples, the size of which grew with test temperature. Some of the precipitates could be identified to be M23C6 based on their cuboid shape.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

EMP Testing of UL489 Circuit Breakers

Sandia National Laboratories (SNL) is performing a test campaign for the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) to address high-altitude electromagnetic pulse (HEMP) vulnerability of critical components of generation stations, with focus on early-time (E1) HEMP. The campaign seeks to establish response and damage thresholds for these critical elements in response to reasonable HEMP threat levels as a means for determining where vulnerabilities may exist or where mitigations may be needed. This report provides component vulnerability test results that will help to inform site vulnerability assessments and HEMP mitigation planning.

42 ENGINEERING↗

Development of Temperature Compensation Tools for SPNDs Operating in High Temperature Environments

Two rhodium-based self-powered neutron detectors (Rh-SPNDs) were irradiated at the Massachusetts Institute of Technology Reactor as a follow-on experiment to the heated irradiation previously conducted at the Neutron Radiography facility at Idaho National Laboratory. The experiment was conducted over the temperature ranges of 600-850°C to further examine the effects of temperature on the Rh-SPNDs. Four tests of varying temperature and power were performed. The tests identified two types of temperature effects consistent with historical evaluations. One effect is a prompt proportionality to temperature at steady-state reactor power due to the decrease in Rh-SPND insulation resistance. The other effect is a delayed effect generated from displacement currents generated by changing the space charge within the insulator as a function of temperature. The result of this experiment demonstrates a characterizable responses to temperature that is feasible for developing a temperature compensation tool for SPND operating in high temperatures. The characteristics identified in this experiment will be integrated within the delayed-response compensation techniques for FY23 evaluation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technology Maturation of Wireless Harsh Environment Sensors For Improved Condition Based Monitoring Of Coal Fired Power Generation

The overall goal of this project was to demonstrate and develop the usage of high-temperature (HT) harsh-environment (HE) wireless surface acoustic wave resonator (SAWR) sensor technology to promote reliable maintenance through condition-based maintenance (CBM) for field applications in harsh service conditions associated with power plant environments. The project aimed to advance the HT HE wireless SAWR sensor technology from TRL 5 to TRL 7. In addition to HT HE wireless temperature sensing, efforts were dedicated during this project to investigate, develop and increase the TRL from 3 to 5 for the following technologies: (a) HT HE strain sensors to address additional CBM monitoring needs, such as boiler tube mechanical / thermal stresses, which can provide early indications for boiler tube cracking and failure; and (b) HT aluminum nitride (AlN) and scandium aluminum nitride (ScAlN) based piezoelectric thin film fabrication and implementation of SAW sensors, with the goal of releasing the need to use single crystal piezoelectric materials for SAWRs and thus broaden possible technology applications to non-planar and harder to modify surfaces. To achieve the goals mentioned above, UMaine and its partner, Environetix Technologies Corporation, established partnerships with the following power plants: Longview Power (Maidsville, WV), a coal-fired power plant; Penobscot Energy Recovery Corp (PERC, Orrington, ME), a waste-to-energy power plant; and the UMaine Steam Plant (Orono, ME), an oil / natural gas power plant. To realize wireless HT HE SAWR sensor systems in these harsh service conditions, the University of Maine research team worked with Environetix and these power plants to define, design, fabricate, test and validate a mature prototype wireless temperature SAWR sensor system for boiler tube applications within the HT HE of the reheater pass damper chamber to directly and wirelessly monitor the temperature at eighteen independent boiler tube locations. The system included three levels, or “tiers”, of wireless communication to enable remote monitoring: Tier 1, the wireless link in the reheater pass damper chamber directly accessing the sensors on the boilers; Tier 2, the wireless local area network link, transmitting processed sensor information within the power plant to the Tier 3, a commercial wireless signal carrier company for secure remote data monitoring outside of the power plant. Regarding the wireless sensor system installed at Longview Power, temperature information from the boilers was continuously transmitted from the Longview boilers at Maidsville, WV, to Environetix headquarters, Orono, ME, over a 34 month period, when the system was finally decommissioned. Strain sensors and piezoelectric ScAlN thin film sensors were successfully installed on the exhaust duct at the UMaine Steam Power plant. The advances in wireless strain sensors and thin film piezoelectric film fabrication and testing were performed mostly in UMaine laboratories and field tested at the UMaine Steam Plant, due to its close proximity to UMaine/Environetix, access to the plant facility, and due to difficulties in accessing the other power plants during the COVID shut-down period. The project accomplished the TRL level increase of the targeted CBM technologies through the successful fabrication, installation, test, and validation of dedicated and commercial wireless sensor systems, utilizing the three different power plants. The outcomes of this project, including the wireless sensor data capability, are expected to yield an advance for CBM in harsh power plant environments. The reduction of maintenance costs, improved safety during plant operation, and increased power plant efficiency will lead to increased revenues (i.e., fewer forced outages) due to better process monitoring enabled by the wireless HT HE SAWR temperature sensor technology.

20 FOSSIL-FUELED POWER PLANTS↗

FY24 Progress Report: SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking

Algorithms for Machine Learning (ML) and data analysis for the 3013 Surveillance Program have been developed in an ongoing collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). The objective of the algorithms is to automate the identification of corrosion and crack formation in the Inner Container Closure Weld Region (ICCWR) of the canister system used to store Pu-bearing material. Data for corrosion and cracking is collected from large binary files generated by a Laser Confocal Microscope (LCM), the Wide Area 3D Measurement System (WAMS), or,in a recent proposal, by a Scanning Electron Microscope (SEM). The ML software uses the physical attributes in the data files (e.g., one or more of: height, color, and 16-bit grayscale values as functions of position in a plane projection) to detect signs of surface corrosion and cracking after being trained on similar data, with the features to be detected. Although the initial scope included screening for broader indicators of corrosion, e.g., pitting, identification of potential cracks was prioritized for the past several years at the request of program leadership. Labeled training data is essential to developing the ML algorithm, and enhancements to data labeling capability have been developed to address this essential precursor to application of ML routines. Efficient labeling is particularly important in view of the large volume of data required to train ML algorithms and the relative rarity of cracks in the ICCWR data set. The updated program will read binary data from either LCM, WAMS or SEM files, interrogate data attributes, facilitate user labeling of data for training ML algorithms, execute ML algorithms, output parameters from trained ML algorithms, report ML model accuracy with respect to labeled data, and generate graphical representations for various analyses. In FY24, hourglass neural networks (HNNs) that were initiated in FY22 were further developed and tested using available LCM data, and their performance was tested against that of the alternative U-Net Neural Network algorithm structure. HNNs along with previously developed Convolutional Neural Networks (CNNs) and Deep Neural Networks (DNNs) comprise a suite of ML tools for identification of cracks in the ICCWR

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

REGULATORY TESTING AND 3D SCANNING METHODOLOGY OF THE DPP-1 TYPE SHIPPING CONTAINER FOR NCT AND HAC TESTS

The safe transportation of radioactive material using appropriately designed and certified transportation packages is important to protect the public and environment. In the United States of America all transportation of radioactive material is regulated by the Department of Transportation (DOT) along with input by the Nuclear Regulatory Commission (NRC). All packages that contain radioactive material requires that it be transported and regulated by the requirements set by the DOT Class 7 hazardous material transportation. Federal regulations place strict administrative controls on the transport of radioactive materials. The two main goals for transporting radioactive materials are 1. Safety should be the primarily focused on the package because it is the first line of defense. 2. Package integrity should be directly related to the degree of the hazard of the radioactive material contents. The two-part goal ensures that the right package is used. Type B packages are designed to transport radioactive materials with the highest level of radioactivity. Examples of material transported in Type B packagings include spent nuclear fuel, high-level radioactive waste, and high concentrations of other radioactive materials. The purpose of this test protocol is to determine the effects of drop and thermal testing on package performance in a Type B shipping package (DPP-1). Required physical tests for the DPP-1 package include free drop, crush, puncture, penetration, compression, vibration, water spray, water immersion, and thermal. The preparation, regulatory testing, and post-test evaluation of a Type B shipping package tested to the 10 CFR 71.71 and 10 CFR 71.73 requirements will be presented. Six packages were tested and the responses when subjected to the HAC sequence of free drop, puncture, and thermal tests according to 10 CFR 71.73(c)(1), (c)(2), (c)(3) and (c)(4) were measured. The Free Drop, Crush and Puncture tests were performed at the NTRC in Knoxville, TN, and the Thermal tests were performed Southwest Research Institute in San Antonio, TX. The test units were subjected to a pre-operational leak testing before the NCT and HAC tests and a post-operational leak test and a helium leak test once regulatory testing was complete. Finally, all test units were scanned with a handheld blue light scanner to capture a 3D CAD geometry of the test units in the deformed shape. The handheld scanner provided the most effective and reliable way to acquire accurate 3D measurements of the test unit. The scanned geometry was sectioned in areas with deformation and the cross-section profile was measured to determine accurate and repeatable results of the deformed shape of the test units.

Martinez, Oscar↗

The use of idealised experiments in testing a new convective parametrization: Performance of CoMorph-A

CoMorph is a new mass-flux convection parametrization under development at the Met Office designed for use within the Unified Model and its successor model, LFRic. Use of a three-dimensional idealised model enables controlled tests of the performance of the scheme across different regimes. This includes the interaction between the physical parametrizations and the resolved dynamics, allowing study of the emergent organisation of convection on the resolved scale. A selection of well-known cases is revisited here, with the purpose of documenting the extent to which CoMorph captures a range of important, but challenging, behaviour such as the diurnal cycle and sensitivity to tropospheric moisture. Simulations using CoMorph-A, a new physics package, that has been demonstrated to perform well at numerical weather prediction (NWP) and climate scales, are compared against the current global atmosphere configuration and high-resolution results. In addition to an entirely new convection scheme, the package of changes includes significant changes to the cloud, microphysics, and boundary-layer parametrizations. Recognising that CoMorph-A is the first version of a scheme that will continue to be substantially developed and to obtain good performance, compromises in tuning have had to be made. These idealised tests therefore show what works well in this configuration, and what areas will require further work. As such, it is quite a demanding testbed and could be viewed as some of the equipment required for a “convective playground”.

54 ENVIRONMENTAL SCIENCES↗

Heat Transfer Coefficients of Additively Manufactured Tubes with Internal Pin Fins for Supercritical Carbon Dioxide Cycle Recuperators

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO 2 flowing in additively manufactured tubes with internal pin fins at the US DOE’s National Energy Technology Laboratory in Morgantown, WV. The measurement procedures were validated by conducting benchmark tests with smooth stainless-steel tube and comparing the results with published correlations for Nusselt number (Nu) and friction factor. Over Reynolds numbers (ReD) ranging from 5 × 10 4 to 2.5 × 10 5 , measured Nu was within 5% of the Dittus-Boelter correlation and measured friction factors were within 5% of the McAdams correlation for smooth tube flow. The candidate pin fin patterned pipes were additively manufactured (AM) at the Oak Ridge National Laboratory. The pins were circular or elliptical in cross-section and were printed at a 30⁰ angle relative to the inner wall (to meet AM constraints). The pin arrangement was helical to promote enhanced heat transfer due to swirl flow. Pin length to diameter aspect ratio was 1.33, 2, and 8, while the pin diameter to tube diameter ratio was 0.188, 0.125, and 0.063. Tests were performed for ReD varying from 6.9 × 10 4 to 2.2 × 10 5 and at conditions equivalent to the low pressure (LP) outlet (8.69 MPa, 361 K) and the high pressure (HP) inlet (20.7 MPa, 350 K) of the low temperature recuperator (LTR) in an indirect sCO 2 cycle. The Wilson plot technique was utilized to measure the bulk heat transfer coefficients. For the best performing design (tube A, pin length to tube diameter ratio: 1.33, pin diameter to tube diameter ratio: 0.19), the local heat transfer coefficient increased by 136% relative to the Dittus-Boelter correlation at the LTR low pressure outlet and 194% at the LTR high pressure inlet. These correspond to a 282% and a 271% increase in the product of the heat transfer coefficient and surface area (adjusted for fin efficiency) product, respectively. Large pressure drops across the test articles were observed. For Tube Design A, the average friction factor, across the range of ReD considered, was significantly larger than the McAdams correlation at both the LTR LP outlet and the LTR HP inlet. A thermal performance factor was utilized to express the ratio of material required to build a finned heat exchanger relative to a finless heat exchanger with the same heat duty and pumping power. Tube Design A was estimated to decrease the required heat exchanger material by 13%.

Searle, Matthew↗

Thermopile Energy Harvesting for Subsurface Wellbore Sensors (Final Report)

Robust in situ power harvesting underlies all efforts to enable downhole autonomous sensors for real-time and long-term monitoring of CO 2 plume movement and permeance, wellbore health, and induced seismicity. This project evaluated the potential use of downhole thermopile arrays, known as thermoelectric generators (TEGs), as power sources to charge sensors for in situ real-time, long-term data capture and transmission. Real-time downhole monitoring will enable “Big Data” techniques and machine learning, using massive amounts of continuous data from embedded sensors, to quantify short- and long-term stability and safety of enhanced oil recovery and/or commercial-scale geologic CO 2 storage. This project evaluated possible placement of the TEGs at two different wellbore locations: on the outside of the casing; or on the production tubing. TEGs convert heat flux to electrical power, and in the borehole environment, would convert heat flux into or out of the borehole into power for downhole sensors. Such heat flux would be driven by pumping of cold or hot fluids into the borehole—for instance, injecting supercritical CO 2 —creating a thermal pulse that could power the downhole sensors. Hence, wireless power generation could be accomplished with in situ TEG energy harvesting. This final report summarizes the project’s efforts that accomplished the creation of a fully operational thermopile field unit, including selection of materials, laboratory benchtop experiments and thermal-hydrologic modeling for design and optimization of the field-scale power generation test unit. Finally, the report describes the field unit that has been built and presents results of performance and survivability testing. The performance and survivability testing evaluated the following: 1) downhole power generation in response to a thermal gradient produced by pumping a heated fluid down a borehole and through the field unit; and 2) component survivability and operation at elevated temperature and pressure conditions representative of field conditions. The performance and survivability testing show that TEG arrays are viable for generating ample energy to power downhole sensors, although it is important to note that developing or connecting to sensors was beyond the scope of this project. This project’s accomplishments thus traversed from a low Technical Readiness Level (TRL) on fundamental concepts of the application and modeling to TRL-5 via testing of the fully integrated field unit for power generation in relevant environments. A fully issued United States Patent covers the wellbore power harvesting technology and applications developed by this project.

47 OTHER INSTRUMENTATION↗

Thermal Performance of Spandrel Assemblies in Glazed Wall Systems: Laboratory Test Design – Challenges and Test Results

Accurate thermal performance calculation procedures for opaque spandrel areas in curtain wall and window wall systems are essential for rating systems when comparing spandrel systems. However, there is a lack of consensus in thermal modeling needed for accurately characterizing heat transfer through spandrel assemblies due to the complex arrangement of materials and structural components. Several studies indicate that conventional 2D thermal simulations may overestimate R-values by 30% compared to physical testing and 3D simulations. Detailed simulations and well-curated laboratory test data are necessary to build confidence in simulation models, which will later be used to develop correlations to improve widely used conventional 2D thermal simulations. This study aims to experimentally test heat transfer through various spandrel assemblies to validate 3D simulation models. Also, the challenges of conducting a thorough testing design along with the solutions would be documented. The team developed a design for testing spandrel assemblies, making appropriate modifications to the existing heat, air, and moisture (HAM) chamber to accommodate the testing needs. Two moveable baffles were designed and fabricated to guide airflow direction parallel to the test article surface. The data acquisition capabilities in the chamber were upgraded to add more than two hundred sensors to the climate and indoor side of the chamber. The goal is to provide a quality dataset for validating complex 3D modeling simulations, which will be used to develop improved thermal simulation techniques that more accurately represent the thermal behavior of spandrel assemblies and their integration within the building envelope. This paper will summarize the results for the boundary conditions of the testing and the temperature variation across different locations of the spandrel assemblies.

Kunwar, Niraj [ORNL] (ORCID:0000000263457652)↗

Impact of Blockchain Delay on Grid-Tied Solar Inverter Performance

This paper investigates the impact of the delay resulting from a blockchain, a promising security measure, for a hierarchical control system of inverters connected to the grid. The blockchain communication network is designed at the secondary control layer for resilience against cyberattacks. To represent the latency in the communication channel, a model is developed based on the complexity of the blockchain framework. Taking this model into account, this work evaluates the plant’s performance subject to communication delays, introduced by the blockchain, among the hierarchical control agents. In addition, this article considers an optimal model-based control strategy that performs the system’s internal control loop. The work shows that the blockchain’s delay size influences the convergence of the power supplied by the inverter to the reference at the point of common coupling. In the results section, real-time simulations on OPAL-RT are performed to test the resilience of two parallel inverters with increasing blockchain complexity.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Testing the HM-5s and NaIGEM code

We tested the performance of the HM-5 units and the NaIGEM code to determine the uranium enrichment. The uranium materials consist of two groups, the NBS series and the UISO series. The NBS items are U 3 O 8 in aluminum containers with an inner diameter of 7.0 cm and a frontal surface thickness of 2.0 mm. The UISO items are U 3 O 8 stored in doubly encapsulated stainless steel containers with a total thickness of 0.82 mm. The diameter of the inner UISO container is 10.0 cm. Four separate tests were performed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of 7.2× 6.1× 7.0 m3. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV/c to 7 GeV/c. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP's performance, including noise and gain measurements, dE/dx calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP's successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication and testing of high-performance all-metal neutron guides and axisymmetric mirrors by electrochemical replication

Neutron scattering is one of the most useful methods of studying the structure of matter, with applications to biomedical, structural, magnetic and energy-related materials. Neutron-scattering instruments are installed around research reactors or accelerator-based neutron sources, and neutron guides are critical components of these facilities. They are neutron-transport optical devices consisting of state-of-the-art mirrors often tens of meters long. Here we demonstrate a novel fabrication method of all-metallic neutron guides and axisymmetric mirrors by electroplating from precision mandrels. The process allows for the fabrication of single-piece all-metal guides of prismatic and axisymmetric shapes. We also demonstrate supermirror guides and axisymmetric focusing supermirrors produced with the same technology. We present the fabrication and tests of the multilayer-coated replicated guides and optic and show that the mandrel is reproduced with high fidelity and reliability. Furthermore, such supermirror optics will provide game-changing improvements in neutron techniques.

36 MATERIALS SCIENCE↗

Improving GCM Predictability of Mixed-Phase Clouds and Aerosol Interactions at High Latitudes with ARM Observations

The overachieving goal of this project is to improve the predictability of mixed-phase clouds and aerosol interactions in the Community Atmosphere Model version 6 (CAM6) through comparison with the ARM observations. There are three main objectives of the proposed study: (1) Improve the representation of ice microphysical processes in mixed-phase clouds; (2) Test the performance of ice microphysics in CESM-CAM6 with the ARM observations in northern and southern high latitudes; and (3) Examine mixed-phase cloud microphysics-aerosol-turbulence-radiation interactions in CESM-CAM6. In this project, we have (1) Improved the representation of ice microphysical processes in mixed-phase clouds in CESM-CAM6 by implementing the marine organic aerosol (MOA) and treating the ice nucleating particles (INPs) from MOA and its impacts on mixed-phase clouds. We improved the treatment of ice depositional growth through the Wegener–Bergeron–Findeisen (WBF) process by considering the subgrid heterogeneous distributions between liquid droplets and ice crystals in mixed-phase clouds; (2) Tested the performance of ice microphysics in CESM-CAM6 with the ARM observations at high latitudes. We compared the simulated INP concentrations with the ARM observations, e.g., from M-PACE, ISDAC, INPOP, and other data (Mace Head, Zeppelin, CAPRICORN). We examined the impact of improved WBF treatment on model simulated Arctic mixed-phase clouds observed in the M-PACE field campaign. Seasonal variations of modeled mixed-phase cloud properties (LWO, IWP) are compared with the ground-based remote sensing retrievals at the ARM’s NSA $Utqia\dot{g}vik$ site; and (3) Examined mixed-phase cloud microphysics-aerosol-dynamics-radiation interactions in CESM-CAM6 that include the impacts of MOA INPs, and impacts of different model parameterizations (CLUBB versus UW turbulence & shallow convection schemes, MG2 versus MG1) on high-latitude mixed-phase cloud properties. Aerosol indirect effects of MOA through the liquid phase (droplet activation) and ice phase processes (e.g., the glaciation indirect effect) were investigated.

54 ENVIRONMENTAL SCIENCES↗