Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “particle filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Trace Chemical Detection Using Intercalated MXenes as a Signal Enhancing Substrate in Optical Probes

MXenes are 2D materials composed of layered transition metal nitrides or carbides. These materials are synthesized by HF exfoliation from MAX phases (Ti{sub 3}AlC{sub 2}). The 2D nanomaterial was synthesized by the removal of the 'A' element, resulting in a Mxene product (Ti{sub 3}C{sub 2}). MXenes have the general formula M{sub n+1}X{sub n}T{sub x}, where M is an early transition metal, X is Carbon and/or Nitrogen, and T accounts for surface terminated functional groups such as Fluoride, hydroxyl, and oxygen. These materials have very unique properties, similar to graphene, that allows them to be applied in a variety of trace detection techniques including surface-enhanced Raman spectroscopy (SERS). MXenes have also been demonstrated to selectively uptake uranyl ion, UO{sub 2}{sup 2+}. If this property can be combined with SERS or fluorescence detection, it may be possible to use MXenes as the basis for an alternative method to kinetic phosphorescence analysis (KPA) for trace uranyl measurements. Objectives: To confirm that MXene Nano materials are suitable substrates for SERS and sensor development by enhancing Raman signaling. To determine if certain MXene preparation methods yield materials that are more suitable for trace sensing methods. To determine uranyl uptake properties of these MXene materials and test them for analytical signals. Sample Preparation: Preparation of Ti{sub 3}C{sub 2}MXene (at FSU). MXenes were prepared by etching Al from Ti{sub 3}AlC{sub 2} (MAX phase)material. Two etching techniques yield different MXene products: LiF/HCl: Milder reaction, larger MXene flakes. HF: Harsher reaction, smaller flakes, larger layer separation. Products washed to remove etchant, vacuum filtered, and dried. Dried MXene flakes are air-stable. Film preparation for sensor testing (at SRNL): Suspend powder in diH{sub 2}O, purge with Ar, sonicate for 30 min. Centrifuge and collect supernate with suspended particles. Observed LiF-etched Mxene yielded a higher density of particles and darker collected solution. Drop-cast (4 ml) supernate onto slides and dried with Ar. For Rhodamine B (RhB) testing, drop-cast 4 ml drops onto Mxene spots and dried with Ar. Scanning Electron Microscopy conditions: 10 kV Beam energy, high vacuum; Working distance of 8 mm; beam penetration depth appx. 4 microns, beam spot size appx. 2 nanometers. Results: Detection of aluminum correlates with bright spots on image. Presence of aluminum shows that LiF/HCl etching was less thorough than HF etching. Trace Cl detection in LiF images suggests incomplete rinsing. HF has smaller feature size, more layer structure, and increased homogeneity, consistent with expectations. Macroscopic Raman spectroscopy measurements: 532 nm excitation, ∼50 mW with a ∼100 micron spot size (InPhotonics RPB probe). Kaiser Optical Holospec f/1.8 spectrometer with cooled (-60 deg.C) Andor iDus OE420 CCD. LiF 1x supernate showed good signal for trace measurements of Rhodamine B. HF and 1/4x LiF supernates showed little Mxene or Rhodamine B signal. Low deposition densities led to excess background signal from glass slides. For LiF film, response is linear with Rhodamine B concentration over range tested. Will retest with Raman microscope (∼1 micron spot size) to characterize SERS of more dilute LiF and HF etched Mxenes. Conclusions: The LiF etched material was more suitable for macroscopic SERS measurements because it was more concentrated, resulting in a thicker film than the HF etched Mxene and diluted LiF sample. However, the other materials may give greater SERS enhancements, which we hope to determine from measurements with the Raman microscope. From characterization with SEM we concluded that the HF etched Mxene is more uniform/homogenous and has smaller particle size than the LiF etched Mxene. There is still aluminum present in both samples indicating that etching wasn't complete, but the removal of the aluminum was more efficient in the HF method. Path Forward: Observe SERS with Raman microscopy, to obtain better signals for the more diluted samples and be able to compare enhancement effects for the different MXenes. Characterize uranyl sorption into MXene films and test Raman and fluorescence signals. Revisit the etching conditions to improve removal of aluminum. FSU and SRNL will continue to collaborate to create and characterize different Mxene materials and test their usefulness for sensor applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gravity-wave spectra in the atmosphere observed by MST radar, part 4.2B

A universal spectrum of atmospheric buoyancy waves is proposed based on data from radiosonde, Doppler navigation, not-wire anemometer and Jimsphere balloon. The possible existence of such a universal spectrum clearly will have significant impact on several areas in the study of the middle atmosphere dynamics such as the parameterization of sub-grid scale gravity waves in global circulation models; the transport of trace constituents and heat in the middle atmosphere, etc. Therefore, it is important to examine more global wind data with temporal and spatial resolutions suitable for the investigation of the wave spectra. Mesosphere-stratosphere-troposphere (MST) radar observations offer an excellent opportunity for such studies. It is important to realize that radar measures the line-of-sight velocity which, in general, contains the combination of the vertical and horizontal components of the wave-associated particle velocity. Starting from a general oblique radar observation configuration, applying the dispersion relation for the gravity waves, the spectrum for the observed fluctuations in the line-of-sight gravity-wave spectrum is investigated through a filter function. The consequence of the filter function on data analysis is discussed.

Scheffler, A. O.↗

Fast Particle-Wave Interactions and Alfvén Eigenmodes in JET Tokamak Plasmas

This document serves as the closeout report of DOE Grant Award No. DE-FG02-99ER54563 with project period 1 April 2015 through 31 March 2020. The project comprised the international collaboration between MIT and EU scientists on the JET facility to improve our understanding of the physics of energetic particle-wave interactions by measuring the damping rates of stable Alfvén Eigenmodes (AEs) and unstable energetic particle driven modes. More specifically, this project involved the continued participation of MIT, the Culham Centre for Fusion Energy, the Swiss Plasma Center, and theorists from various European laboratories and from UC Irvine. Past contributions from the University of São Paulo are gratefully acknowledged. The Alfvén Eigenmode Active Diagnostic (AEAD) on JET discharges was successfully upgraded in this period and has extracted physically useful information, in primarily deuterium plasma discharges. It is expected that such experiments would be continued during the DT campaign in CY 2021 to assess the damping rates of similar modes in the presence of alpha particles, a product of fusing burning plasma. Only JET would carry out such experiments in the near term in the world. It is important to note that this collaboration was continued under DOE Grant Award No. DE-SC0014264 from 1 April 2020 through the present. In this grant period, the AEAD was upgraded with a set of individual amplifiers for each of a set of six antennas in two toroidally opposite locations. These new amplifiers allowed targeted selection of the antennas’ toroidal spectrum for AEs of interest with toroidal mode number | n | ≤ 20. The resonant detection and measurement of the damping rates of AEs was obtained from magnetic probes that could be compared with theory and simulations. This is a key topic of investigation for ITER and all other next-step fusion experiments, where such modes will interact with energetic particles produced by fusion reactions (alpha particles), Neutral Beam Injection (NBI) and Ion Cyclotron Resonance Heating (ICRH). The majority of the observations during this period were of Toroidal Alfvén Eigenmodes (TAEs) as these are most commonly observed on JET; a number of measurements were made during dedicated TAE experiments. However, a new set of lower frequency band filters were procured with the goal of studying Geodesic Acoustic Modes (GAMs), Beta (Acoustic) AEs (BAE/BAAEs), and Reverse Shear AEs (RSAEs), also predicted by theory. Commissioning and optimizations were successfully completed in this period, and the diagnostic has been in operation during the more recent JET campaigns. Initial results have been obtained in dedicated TAE experiments and successfully compared to drift-kinetic theory. A wide range of theoretical studies have been undertaken in support of the upcoming JET campaigns experiments. To supplement the ongoing use of ideal MHD codes, such as MISHKA during the studies of TAEs, gyrokinetic simulations of low frequency AEs were performed in collaboration with UC Irvine. The Gyrokinetic Toroidal Code (GTC) was used to determine the structure, frequencies and stability of AEs in JET plasmas. Thus, a solid scientific foundation has been laid for future DT campaigns in JET in the 2021 operation period when the damping rates of relevant modes in the presence of alpha particles could be assessed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase Contrast Imaging Diagnostic on DIII-D (1994-2007); Phase Contrast Imaging Diagnostic on DIII-D and Alcator C-Mod (2007-2010); Experimental Study of Waves, Turbulence and Transport, and Model Validation with Phase Contrast Imaging on DIII-D and Alcator C-Mod (2010-2012); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Measuring High-k Turbulence and Alfven modes (2021-2016); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Full Multi-Scale Measurements (2016-2020) (Final Report)

This report describes the first twenty-five years of development and use of the Phase Contrast Imaging (PCI) diagnostic for measuring plasma fluctuations on the DIII–D tokamak. One of the key challenges in moving tokamak technology forward to the stage of a nuclear reactor remains understanding how energy and particles are transported across the magnetic field by the action of turbulence and waves, and PCI provides a highly flexible and capable measurement of these fluctuations. The PCI diagnostic uses a laser beam to probe the plasma and optical filtering to produce an amplitude variation on a linear detector array which provides an image of the density waves in the plasma. The PCI covers an exceptional range in frequency and wavelength of the measured fluctuations, allowing observation of plasma-sized magnetohydrodynamic (MHD) modes and ion- and electron-scale turbulence. Modulation of the beam amplitude allows measurement of radio frequency (RF) waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Space Charge Effects on Spin Polarization in High-Intensity Preinjector

This analytical study investigates the space charge impact on electron beam polarization within the low-energy range, spanning from the polarized electron gun up to the linac. The research study three sections: the gun-to-Wien filter interface, the Wien filter section, and the bunching section. We will comprehensively assess polarization degradation mechanisms in each region characterized by space charge effects. We are planning to simulate the spin tracking through the entire low-energy transmission system using Generalized Particle Tracer (GPT) to validate our analytical findings and includes the higher order components.

43 PARTICLE ACCELERATORS↗

Contamination monitoring of the OSIRIS-REx ISO5 asteroid sample cleanroom

The OSIRIS-REx mission to asteroid Bennu successfully collected hundreds of grams of asteroid regolith in October 2020 [1]. The spacecraft departed Bennu in May 2021 for Earth return and will release the sample canister to be recovered in Utah in September 2023 [2]. Samples will be transported to the curation facility at NASA Johnson Space Center, where an ISO5 equivalent cleanroom has been designed in 2017 and completed in 2021. Aspects of the design and material selection for the cleanroom and its supporting facilities (air handling system, cleanroom floors and walls, filters, paints, etc.) were optimized to minimize effects of organic and inorganic contaminants and offgassing [3]. Since its completion, the lab has been carefully monitored to understand and establish a baseline with respect to multiple environmental aspects – measurement of particle counts, deploying Si wafer witness plates for organic and inorganic contaminants, deploying aluminum foils for a focus on organics with JSC in-house expertise, gas samples, and regular microbial and fungal measurements on selected surfaces and air samples in the cleanroom. This contribution will report on nearly one year of monitoring and highlight several specific aspects that have led to a better understanding of the new cleanroom environment.

carbonaceous asteroid↗

Pragmatic protocols for working cleanly when measuring ice nucleating particles

We report that measuring ice nucleating particles (INPs) is critical for understanding, and modeling, cloud formation, reflectivity, and precipitation patterns. However, because INPs are very rare in the atmosphere, but abundant—sometimes alarmingly so—in the dust that covers all work surfaces, contamination during processing of collected aerosol samples can be a significant hindrance to obtaining accurate measures of INPs. In preparing this technical note, we questioned the cleanliness of every collection and processing step involved in making immersion freezing measurements of INPs re-suspended from filter samples. The aim was to identify, and then minimize, all potential sources of significant contamination, including containers and tools used to store filters and prepare liquid suspensions, gloves, work surfaces, and the polymerase chain reaction (PCR) trays commonly used for sample analysis. While plasticware released few INPs, most gloves readily shed them, but this can be mitigated by using washed cleanroom vinyl or polyethylene gloves. Work surfaces, even those that had been cleaned, were prodigious reservoirs of contaminating INPs, but simply covering them with aluminum foil will provide an INP-free surface. By applying these practices, we developed a method to reduce the background level of INPs on Nuclepore™ polycarbonate filters in our tests to 0 at -25 °C and < 20 at -27 °C, making them suitable for use in all sampling environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Waves in active and passive periodic structures - A review

The theory and recent applications of waves in periodic structures are reviewed. Both the Floquet and coupled waves approach are analyzed in some detail. The theoretical part of the paper includes wave propagation in unbounded and bounded active or passive periodic media, wave scattering from periodic boundaries, source radiation (dipole, Cerenkov, transition, and Smith-Purcell) in periodic media, and pulse transmission through a periodic slab. The applications part covers the recent development in a variety of fields: distributed feedback oscillators, filters, mode converters, couplers, second-harmonic generators, deflectors, modulators, and transducers in the fields of integrated optics and integrated surface acoustics. Work on insect compound eyes, mechanical structures, ocean waves, pulse compressions, temperature waves, and cholesteric liquid crystals, and particles interaction with crystals is briefly reviewed, especially in the case of zeolite crystals and superlattices. Recent advances in fabrication techniques for very fine gratings are also covered.

Elachi, C.↗

Focal-plane optimization for detector noise limited performance in cryogenic Fourier transform spectrometer /FTS/ sensors

A study was performed to determine the optimum focal plane configuration including optics, filters and detector-preamplifier selection. The configuration was optimized particularly with respect to minimizing the noise level, but fabrication considerations for a cryogenic environment were also taken into account. The noise terms from source, background, detector electronics and charged particle radiation were quantitatively evaluated. It appears that noise equivalent spectral radiance less than 10 to the -11th W/sq cm per sr per kayser can be achieved between 2.5 and 20 microns.

Mcguirk, M.↗

Atmospheric Emission Photometric Imaging (AEPI)

The atmospheric emission photometric imaging (AEPI) consists of a dual channel, low light level video system with a filter wheel to isolate the emissions of interest, mounted on a stabilized, two axis gimbal system for pointing and control. The objectives are to produce images of various atmospheric emissions to: investigate ionospheric transport processes; observe induced emissions from artificial particle injection; measure electron impact cross sections of atmospheric species; study natural aurora at high spatial and temporal resolutions and in the ultraviolet.

Roberts, W. T.↗

Atmospheric Emission Photometric Imaging (AEPI)

The atmospheric emission photometric imaging (AEPI) consists of a dual channel, low light level video system with a filter wheel to isolate the emissions of interest, mounted on a stabilized, two axis gimbal system for pointing and control. The objectives are to produce images of various atmospheric emissions to: investigate ionospheric transport processes; observe induced emissions from artificial particle injection; measure electron impact cross sections of atmospheric species; study natural aurora at high spatial and temporal resolutions and in the ultraviolet.

Roberts, B.↗

Improving initialization and evolution accuracy of cosmological neutrino simulations

Neutrino mass constraints are a primary focus of current and future large-scale structure (LSS) surveys. Non-linear LSS models rely heavily on cosmological simulations — the impact of massive neutrinos should therefore be included in these simulations in a realistic, computationally tractable, and controlled manner. Here, a recent proposal to reduce the related computational cost employs a symmetric neutrino momentum sampling strategy in the initial conditions. We implement a modified version of this strategy into the Hardware/Hybrid Accelerated Cosmology Code (HACC) and perform convergence tests on its internal parameters. We illustrate that this method can impart Script $\mathcal{O}$(1%) numerical artifacts on the total matter field on small scales, similar to previous findings, and present a method to remove these artifacts using Fourier-space filtering of the neutrino density field. Moreover, we show that the converged neutrino power spectrum does not follow linear theory predictions on relatively large scales at early times at the 15% level, prompting a more careful study of systematics in particle-based neutrino simulations. We also present an improved method for backscaling linear transfer functions for initial conditions in massive neutrino cosmologies that is based on achieving the same relative neutrino growth as computed with Boltzmann solvers. Our self-consistent backscaling method yields sub-percent accuracy in the total matter growth function. Comparisons for the non-linear power spectrum with the Mira-Titan emulator at a neutrino mass of m ν = 0.15 eV are in very good agreement with the expected level of errors in the emulator and in the direct N-body simulation.

79 ASTRONOMY AND ASTROPHYSICS↗

The ISEE-C plasma wave investigation

The ISEE-C plasma wave investigation is designed to provide comprehensive information on interplanetary wave-particle interactions. Three spectrum analyzers with a total of 19 bandpass channels cover the frequency range 0.3 Hz to 100 kHz. The main analyzer, which uses 16 continuously active amplifiers, gives two complete spectral scans per second in each of 16 filter channels. The instrument sensors include a high-sensitivity magnetic search coil, and electric antennas with effective lengths of 0.6 and 45 m.

Scarf, F. L.↗

Automated identification of local contamination in remote atmospheric composition time series

Abstract. Atmospheric observations in remote locations offer a possibility of exploring trace gas and particle concentrations in pristine environments. However, data from remote areas are often contaminated by pollution from local sources. Detecting this contamination is thus a central and frequently encountered issue. Consequently, many different methods exist today to identify local contamination in atmospheric composition measurement time series, but no single method has been widely accepted. In this study, we present a new method to identify primary pollution in remote atmospheric datasets, e.g., from ship campaigns or stations with a low background signal compared to the contaminated signal. The pollution detection algorithm (PDA) identifies and flags periods of polluted data in five steps. The first and most important step identifies polluted periods based on the derivative (time derivative) of a concentration over time. If this derivative exceeds a given threshold, data are flagged as polluted. Further pollution identification steps are a simple concentration threshold filter, a neighboring points filter (optional), a median, and a sparse data filter (optional). The PDA only relies on the target dataset itself and is independent of ancillary datasets such as meteorological variables. All parameters of each step are adjustable so that the PDA can be “tuned” to be more or less stringent (e.g., flag more or fewer data points as contaminated). The PDA was developed and tested with a particle number concentration dataset collected during the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition in the central Arctic. Using strict settings, we identified 62 % of the data as influenced by local contamination. Using a second independent particle number concentration dataset also collected during MOSAiC, we evaluated the performance of the PDA against the same dataset cleaned by visual inspection. The two methods agreed in 94 % of the cases. Additionally, the PDA was successfully applied to a trace gas dataset (CO2), also collected during MOSAiC, and to another particle number concentration dataset, collected at the high-altitude background station Jungfraujoch, Switzerland. Thus, the PDA proves to be a useful and flexible tool to identify periods affected by local contamination in atmospheric composition datasets without the need for ancillary measurements. It is best applied to data representing primary pollution. The user-friendly and open-access code enables reproducible application to a wide suite of different datasets. It is available at https://doi.org/10.5281/zenodo.5761101 (Beck et al., 2021).

54 ENVIRONMENTAL SCIENCES↗

Analytical estimation of the signal to noise ratio efficiency in axion dark matter searches using a Savitzky-Golay filter

The signal to noise ratio efficiency ϵ SNR in axion dark matter searches has been estimated using large-statistic simulation data reflecting the background information and the expected axion signal power obtained from a real experiment. This usually requires a lot of computing time even with the assistance of powerful computing resources. Employing a Savitzky-Golay filter for background subtraction, in this work, we estimated a fully analytical ϵ SNR without relying on large-statistic simulation data, but only with an arbitrary axion mass and the relevant signal shape information. Hence, our work can provide ϵ SNR using minimal computing time and resources prior to the acquisition of experimental data, without the detailed information that has to be obtained from real experiments. Axion haloscope searches have been observing the coincidence that the frequency independent scale factor ξ is approximately consistent with the ϵ SNR . This was confirmed analytically in this work, when the window length of the Savitzky-Golay filter is reasonably wide enough, i.e., at least 5 times the signal window.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Scanning laser-velocimeter technique for measuring two-dimensional wake-vortex velocity distributions

A rapid scanning two dimensional laser velocimeter (LV) has been used to measure simultaneously the vortex vertical and axial velocity distributions in the Langley Vortex Research Facility. This system utilized a two dimensional Bragg cell for removing flow direction ambiguity by translating the optical frequency for each velocity component, which was separated by band-pass filters. A rotational scan mechanism provided an incremental rapid scan to compensate for the large displacement of the vortex with time. The data were processed with a digital counter and an on-line minicomputer. Vaporized kerosene (0.5 micron to 5 micron particle sizes) was used for flow visualization and LV scattering centers. The overall measured mean-velocity uncertainity is less than 2 percent. These measurements were obtained from ensemble averaging of individual realizations.

Gartrell, L. R.↗