Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optimality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Optimization of the moderators in the STS preliminary design

This report details the results for an optimization of the dimensions of the moderators in the preliminary design of the Spallation Neutron Source Second Target Station (STS). This study uses the optimization algorithms of Dakota and an unstructured mesh model for the moderators in MCNP. More details on the unstructured mesh model and the automated mesh generation can be found in [3]. Parallel to this effort, the same moderator geometries have been optimized using a constructive solid geometry (CSG) MCNP model. More details on this model and its results can be found in [4]. Three optimal designs are selected for each moderator: one that is optimized for maximum peak brightness, one for maximum time-integrated brightness, and one for a combination of peak and time-integrated brightness. The backbone of the optimization work flow is provided by Dakota. For each set of design parameters requested by Dakota, a new solid geometry is automatically built in Creo and SpaceClaim, and subsequently exported to Attila4MC to generate an unstructured mesh geometry for MCNP. After the MCNP calculation is finished, the objective function (e.g., brightness metric) is returned to Dakota. After the new design has been evaluated, a result-file is written, and Dakota proposes the next set of design parameters to be evaluated. The loop continues until a specified convergence criterion has been met. The design parameters of the cylindrical (upper) moderator include the hydrogen radius, the premoderator thickness (top, bottom, radial), the beryllium radius and the horizontal position of the moderator. The crucial design choice is the hydrogen radius. A radius of 62 mm is shown to provide the maximum time-integrated brightness. The maximum peak brightness occurs with a radius of 40 mm. A combined (middle) design, which balances peak and time-integrated brightnesses, is obtained with a hydrogen radius of 50 mm. The premoderator thicknesses and the beryllium radius are slightly larger in the design optimized for time-integrated brightness than in the design optimized for peak brightness. The sensitivity to these two parameters is relatively small close to the optimal configurations. The hydrogen vessel and vacuum vessel wall thicknesses are dependent on the radius of the liquid hydrogen due to structural integrity requirements. The increased wall thicknesses for larger vessels significantly penalize the time-integrated brightness, with the maximum obtainable value reduced by more than 10% relative to earlier studies which used fixed vessel wall thicknesses. The impact of the variable wall thicknesses is much less for the peak brightness and combined brightness designs. The design parameters of the tube (lower) moderator selected for the optimization are the tube length, the annular premoderator thickness, the beryllium radius and the horizontal position of the moderator. The tube length is the crucial parameter and is chosen large (210 mm) and small (125 mm) in the designs optimized for time-integrated and peak brightness respectively. A combined optimal design has a tube length of 170 mm. The premoderator thickness and the beryllium radius are chosen larger in the design optimized for time-integrated brightness.

42 ENGINEERING↗

Coupled Target-Beam-Moderator Optimization for the Second Target Station

This report describes the results for a coupled target-beam-moderator optimization analysis for the Second Target Station (STS) at ORNL's Spallation Neutron Source. This study is a continuation of the optimization analysis for the moderators in the preliminary design of STS performed in 2022. In the 2022 analysis the dimensions of the moderators are parameterized, while the target and the proton beam profile are kept constant. In this analysis the target height and the proton beam profile are added as parameters. This allows to study the coupled effects of changing target, moderator and beam dimensions. Similar to the 2022 analysis, this work is performed with an automated optimization workflow that uses the optimization toolbox DAKOTA, parameterized geometries in CREO and SpaceClaim, the unstructured mesh generation in Attila4MC, and the particle transport code MCNP6.2©. This workflow enables an efficient optimization using high-fidelity geometries. The main conclusions of this analysis are the following: • Coupled beam-target-moderator optimization provides a few additional percent performance gain over stand-alone moderator optimization. • The moderator performance is not very sensitive to the target height (between ≈60 and ≈80 mm) as long as the beam profile is chosen adequately. • The moderator performance is sensitive to the choice of beam spatial standard deviations, even when the footprint is kept constant. • The optimal moderator radius is the same for a beam footprint of 30 cm 2 , 62.5 cm 2 , and 90 cm 2 . Also the slope of the super-gaussian beam profile does not significantly impact the optimal moderator radius. • The optimal parameters and sensitivities are very similar to the 2022 optimization analysis. These results only indicate a a difference in the optimal radius of the cylindrical moderator, however, this has been corrected in the final design moderator optimization. The main purpose of this report is to document the simulations, results and lessons learned. The most impactful results are summarized in. We also note that the target geometry used in this work is not the final design.

43 PARTICLE ACCELERATORS↗

Minimum feature size control in level set topology optimization via density fields

A level set topology optimization approach that uses an auxiliary density field to nucleate holes during the optimization process and achieves minimum feature size control in optimized designs is explored. The level set field determines the solid-void interface and the density field describes the distribution of a fictitious porous material using the solid isotropic material with penalization. These fields are governed by two sets of independent optimization variables which are initially coupled using a penalty for hole nucleation. The strength of the density field penalization and projection is gradually increased during the optimization process to promote a 0-1 density distribution. In addition, a second penalty regulates the evolution of the density field in the void phase. The treatment of the density field combined with the second penalty mitigate the appearance of small design features. The minimum feature size of optimized designs is controlled by the radius of the linear filter applied to the density optimization variables. The structural response is predicted by the extended finite element method, the sensitivities by the adjoint method, and the optimization variables are updated by a gradient-based optimization algorithm. Numerical examples investigate the robustness of this approach with respect to algorithmic parameters and mesh refinement. The results show the applicability of the combined density level set topology optimization approach for both optimal hole nucleation and for minimum feature size control in 2D and 3D. This comes, however, at the cost of a more complex problem formulation and additional computational cost due to an increased number of optimization variables.

42 ENGINEERING↗

Progress on Optimizing Wind Farms and Rotor Designs Using Adjoints

Modern wind plants are increasingly tasked with multiple performance objectives. In addition to designing plants that maximize power output and minimize the levelized cost of energy (LCOE), the design and operation of wind plants is increasingly influenced by challenges regarding grid integration of variable generation renewables. This places a growing emphasis on making wind plants more controllable and predictable. WindSE is a Reynolds-averaged Navier-Stokes (RANS) model designed around analytical gradient and adjoint methods, with the ability to capture terrain-induced effects, as shown in Figure 1. The recent addition of an unsteady solver with an actuator line method (ALM) and ongoing work to enable massively parallel optimizations gives it a unique niche to explore coupled plant-level controls and design problems. This code is an open source python package built on the FEniCS framework that utilizes fast, parallel PETSc solvers to model fluid flow throughout wind-farm scale domains. Two recent studies performed using WindSE demonstrate the capability to optimize under a wide variety of flow conditions and objective functions. In the first, we present an optimization focused on modifying the layout of a wind farm with a fixed number of turbines for maximum total power output [1]. This study highlights the ability to quickly perform simulations using the steady Navier-Stokes solver combined with rotors represented as actuator disks while also stressing the importance of capturing terrain-induced effects. Gradient-based optimization using the RANS equations is viable due to the inclusion of efficiently computed adjoint derivatives. We interpret the physical results of the optimal layout and also discuss the computational cost of scaling to larger problems. In the second study, we present the capabilities of the unsteady Navier-Stokes solver, where rotor-blade profiles represented by actuator lines are optimized to enhance wake steering effects and overall power production [2]. We quantify the wind plant performance gains obtained from this type of simultaneous control co-design optimization as compared to optimizing the blade design and yaw independently. Figure 2 shows the differences between a baseline two-turbine system and an optimized system where we fine-tune the blade chord profile. Results and challenges from each study are quickly summarized and used to motivate the current development efforts within WindSE. Current and future work is focused on enabling higher-resolution studies with more degrees of freedom through parallelization of both the simulation and optimization algorithms. We present benchmarking results to show that WindSE performs well in both weak- and strong-scaling tests and further demonstrate that the optimizer obtains the same convergence rates in both shared- and distributed-memory environments. Using larger wind farms, we can study deep-array effects within an optimization context, allowing the use of objective functions that have been previously unstudied. As an example, we present ongoing work on a blockage metric which characterizes the loss of available kinetic energy due to wake effects from multiple upstream turbines.

adjoint optimization↗

Comparison of multiobjective optimization methods for the $\mathrm{LCLS-II}$ photoinjector

Particle accelerators are among some of the largest science experiments in the world and can consist of thousands of components with a wide variety of input ranges. These systems can easily become unwieldy optimization problems during design and operations studies. Starting in the early 2000s, searching for better beam dynamics configurations became synonymous with heuristic optimization methods in the accelerator physics community. Genetic algorithms and particle swarm optimization are currently the most widely used. These algorithms can take thousands of simulation evaluations to find optimal solutions for one machine prototype. For large facilities such as the Linac Coherent Light Source (LCLS) and others, this equates to a limited exploration of many possible design configurations. In this paper, the LCLS-II photoinjector is optimized with three optimization algorithms. All optimizations were started from both a uniform random and Latin hypercube sample. In all cases, the optimizations started from Latin hypercube samples outperformed optimizations started from uniform samples. All three algorithms were able to optimize the photoinjector, with the model-based methods approximating the Pareto front in fewer simulation evaluations. This work, in combination with previous optimization observations, indicates objective penalties have a strong impact on the efficiency of such methods. In general, we recommend heuristic methods for initial optimizations and model-based methods when information about the objective space is available.

43 PARTICLE ACCELERATORS↗

Effectiveness of robust optimization in intensity-modulated proton therapy planning for head and neck cancers

Purpose: Intensity-modulated proton therapy (IMPT) is highly sensitive to uncertainties in beam range and patient setup. Conventionally, these uncertainties are dealt using geometrically expanded planning target volume (PTV). In this paper, the authors evaluated a robust optimization method that deals with the uncertainties directly during the spot weight optimization to ensure clinical target volume (CTV) coverage without using PTV. The authors compared the two methods for a population of head and neck (H and N) cancer patients. Methods: Two sets of IMPT plans were generated for 14 H and N cases, one being PTV-based conventionally optimized and the other CTV-based robustly optimized. For the PTV-based conventionally optimized plans, the uncertainties are accounted for by expanding CTV to PTV via margins and delivering the prescribed dose to PTV. For the CTV-based robustly optimized plans, spot weight optimization was guided to reduce the discrepancy in doses under extreme setup and range uncertainties directly, while delivering the prescribed dose to CTV rather than PTV. For each of these plans, the authors calculated dose distributions under various uncertainty settings. The root-mean-square dose (RMSD) for each voxel was computed and the area under the RMSD-volume histogram curves (AUC) was used to relatively compare plan robustness. Data derived from the dose volume histogram in the worst-case and nominal doses were used to evaluate the plan optimality. Then the plan evaluation metrics were averaged over the 14 cases and were compared with two-sided paired t tests. Results: CTV-based robust optimization led to more robust (i.e., smaller AUCs) plans for both targets and organs. Under the worst-case scenario and the nominal scenario, CTV-based robustly optimized plans showed better target coverage (i.e., greater D{sub 95%}), improved dose homogeneity (i.e., smaller D{sub 5%}- D{sub 95%}), and lower or equivalent dose to organs at risk. Conclusions: CTV-based robust optimization provided significantly more robust dose distributions to targets and organs than PTV-based conventional optimization in H and N using IMPT. Eliminating the use of PTV and planning directly based on CTV provided better or equivalent normal tissue sparing.

60 APPLIED LIFE SCIENCES↗

Individually optimized uniform contrast enhancement in CT angiography for the diagnosis of pulmonary thromboembolic disease—A simulation study

Purpose: To improve the diagnostic quality of CT pulmonary angiography (CTPA) by individually optimizing a biphasic contrast injection function to achieve targeted uniform contrast enhancement. To compare the results against a previously reported discrete Fourier transform (DFT) approach. Methods: This simulation study used the CTPA datasets of 27 consecutive patients with pulmonary thromboembolic disease (PE). An optimization approach was developed consisting of (1) computation of the impulse enhancement function (IEF) based on a test bolus scan, and (2) optimization of a biphasic contrast injection function using the IEF in order to achieve targeted uniform enhancement. The injection rates and durations of a biphasic contrast injection function are optimized by minimizing the difference between the resulting contrast enhancement curve and the targeted uniform enhancement curve, while conforming to the clinical constraints of injection rate and total contrast volume. The total contrast volume was limited first to the clinical standard of 65 ml, and then to the same amount used in the DFT approach for comparison. The optimization approach and the DFT approach were compared in terms of the root mean square error (RMSE) and total contrast volume used. Results: When the total contrast volume was limited to 65 ml, the optimization approach produced significantly better contrast enhancement (closer to the targeted uniform contrast enhancement) than the DFT approach (RMSE 17 HU vs 56 HU,p < 0.00001). On average, the optimization approach used 63 ml contrast, while the DFT approach used 50 ml with four patients exceeding 65 ml. When equivalent total contrast volume was used for individual patient, the optimization approach still generated significantly better contrast enhancement (RMSE 44 HU vs 56 HU, p < 0.01). Constraints for the injection function could be easily accommodated into the optimization process when searching for the optimal biphasic injection function. Conclusions: The optimization approach generated individually optimized biphasic injection functions yielding significantly better contrast enhancement compared to the DFT approach. This new approach has the potential to improve the diagnostic quality of CTPA for PE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-R-10: Selecting the Optimal Solution for Multi-Objective Radiomics Model

Purpose: To develop an evidential reasoning approach for selecting the optimal solution from a Pareto solution set obtained by a multi-objective radiomics model for predicting distant failure in lung SBRT. Methods: In the multi-objective radiomics model, both sensitivity and specificity are considered as the objective functions simultaneously. A Pareto solution set with many feasible solutions will be resulted from the multi-objective optimization. In this work, an optimal solution Selection methodology for Multi-Objective radiomics Learning model using the Evidential Reasoning approach (SMOLER) was proposed to select the optimal solution from the Pareto solution set. The proposed SMOLER method used the evidential reasoning approach to calculate the utility of each solution based on pre-set optimal solution selection rules. The solution with the highest utility was chosen as the optimal solution. In SMOLER, an optimal learning model coupled with clonal selection algorithm was used to optimize model parameters. In this study, PET, CT image features and clinical parameters were utilized for predicting distant failure in lung SBRT. Results: Total 126 solution sets were generated by adjusting predictive model parameters. Each Pareto set contains 100 feasible solutions. The solution selected by SMOLER within each Pareto set was compared to the manually selected optimal solution. Five-cross-validation was used to evaluate the optimal solution selection accuracy of SMOLER. The selection accuracies for five folds were 80.00%, 69.23%, 84.00%, 84.00%, 80.00%, respectively. Conclusion: An optimal solution selection methodology for multi-objective radiomics learning model using the evidential reasoning approach (SMOLER) was proposed. Experimental results show that the optimal solution can be found in approximately 80% cases.

60 APPLIED LIFE SCIENCES↗

SU-F-J-133: Adaptive Radiation Therapy with a Four-Dimensional Dose Calculation Algorithm That Optimizes Dose Distribution Considering Breathing Motion

Purpose: To model patient motion and produce four-dimensional (4D) optimized dose distributions that consider motion-artifacts in the dose calculation during the treatment planning process. Methods: An algorithm for dose calculation is developed where patient motion is considered in dose calculation at the stage of the treatment planning. First, optimal dose distributions are calculated for the stationary target volume where the dose distributions are optimized considering intensity-modulated radiation therapy (IMRT). Second, a convolution-kernel is produced from the best-fitting curve which matches the motion trajectory of the patient. Third, the motion kernel is deconvolved with the initial dose distribution optimized for the stationary target to produce a dose distribution that is optimized in four-dimensions. This algorithm is tested with measured doses using a mobile phantom that moves with controlled motion patterns. Results: A motion-optimized dose distribution is obtained from the initial dose distribution of the stationary target by deconvolution with the motion-kernel of the mobile target. This motion-optimized dose distribution is equivalent to that optimized for the stationary target using IMRT. The motion-optimized and measured dose distributions are tested with the gamma index with a passing rate of >95% considering 3% dose-difference and 3mm distance-to-agreement. If the dose delivery per beam takes place over several respiratory cycles, then the spread-out of the dose distributions is only dependent on the motion amplitude and not affected by motion frequency and phase. This algorithm is limited to motion amplitudes that are smaller than the length of the target along the direction of motion. Conclusion: An algorithm is developed to optimize dose in 4D. Besides IMRT that provides optimal dose coverage for a stationary target, it extends dose optimization to 4D considering target motion. This algorithm provides alternative to motion management techniques such as beam-gating or breath-holding and has potential applications in adaptive radiation therapy.

60 APPLIED LIFE SCIENCES↗

Component-to-Optimization Workflow Demonstration

This report aims to demonstrate workflow-generating algorithms for optimizing dispatch across a broad range of Integrated Energy System applications using the Framework for Optimization of Resources and Economics (FORCE) tool suite. The optimization is performed at two different time scales. In the coarse time scale, the optimization focuses on a class of energy sources and consumers and aims to find the optimal combinations and flows of energy based on real-time price data information. In the fine time scale, the optimization focuses on a specific thermal energy delivery system and aims to find the optimal setpoints of components in order to meet the energy demands from coarse-time-scale optimizations. In this demonstration, the coarse-scale optimization is implemented using the newly developed Dispatch Optimization Variable Engine (DOVE), while the fine-scale optimization used Optimization of Real-Time Capacity Allocation (ORCA).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Insights into Constraining Rate Coefficients in Fuel Oxidation Mechanisms Using Genetic Algorithm Optimization

Accurate fuel oxidation mechanisms can enable predictive capabilities that aid in advancing combustion technologies. High-level computational kinetics can yield reasonable rate coefficients with uncertainties, in some cases, below a factor of 2. Computed rate coefficients can be constrained further by optimizing against experimental data. Here, we explore the application of genetic algorithm (GA) optimization to constrain computed rate coefficients in complex fuel oxidation mechanisms in conjunction with temperature-dependent species mole fractions from jet-stirred reactor (JSR) measurements. Cyclohexane is a model candidate for understanding the reactivity of cyclic fuels. In this work, we optimize the rate coefficients of the most recent literature cyclohexane mechanism, which incorporates theoretically computed rate coefficients for the reaction networks stemming from the first and second O 2 addition pathways, against the experimental results of two separate literature JSR studies. Optimization consistency is evaluated by carrying out three GA optimizations: fitting to the temperature-dependent species mole fractions in each JSR experiment separately and simultaneously fitting the species mole fractions in both experiments. Local sensitivity analyses are used to identify five influential low-temperature oxidation reactions for optimization. Although the three optimizations do not yield identical rate coefficients, the direction of change in all five rate coefficients is consistent among the three optimizations. Performance of the models from the three optimizations is assessed against literature ignition delay times with differences in the level of agreement observed among the different optimizations. In conclusion, comparisons are made with our recent optimization work of a cyclopentane oxidation master-equation model against time-resolved species concentrations, and insights and improvements of the strategy for constraining rate coefficients using GA optimization are discussed.

33 ADVANCED PROPULSION SYSTEMS↗

iCycle: Integrated, multicriterial beam angle, and profile optimization for generation of coplanar and noncoplanar IMRT plans

Purpose: To introduce iCycle, a novel algorithm for integrated, multicriterial optimization of beam angles, and intensity modulated radiotherapy (IMRT) profiles. Methods: A multicriterial plan optimization with iCycle is based on a prescription called wish-list, containing hard constraints and objectives with ascribed priorities. Priorities are ordinal parameters used for relative importance ranking of the objectives. The higher an objective priority is, the higher the probability that the corresponding objective will be met. Beam directions are selected from an input set of candidate directions. Input sets can be restricted, e.g., to allow only generation of coplanar plans, or to avoid collisions between patient/couch and the gantry in a noncoplanar setup. Obtaining clinically feasible calculation times was an important design criterium for development of iCycle. This could be realized by sequentially adding beams to the treatment plan in an iterative procedure. Each iteration loop starts with selection of the optimal direction to be added. Then, a Pareto-optimal IMRT plan is generated for the (fixed) beam setup that includes all so far selected directions, using a previously published algorithm for multicriterial optimization of fluence profiles for a fixed beam arrangement Breedveld et al.[Phys. Med. Biol. 54, 7199-7209 (2009)]. To select the next direction, each not yet selected candidate direction is temporarily added to the plan and an optimization problem, derived from the Lagrangian obtained from the just performed optimization for establishing the Pareto-optimal plan, is solved. For each patient, a single one-beam, two-beam, three-beam, etc. Pareto-optimal plan is generated until addition of beams does no longer result in significant plan quality improvement. Plan generation with iCycle is fully automated. Results: Performance and characteristics of iCycle are demonstrated by generating plans for a maxillary sinus case, a cervical cancer patient, and a liver patient treated with SBRT. Plans generated with beam angle optimization did better meet the clinical goals than equiangular or manually selected configurations. For the maxillary sinus and liver cases, significant improvements for noncoplanar setups were seen. The cervix case showed that also in IMRT with coplanar setups, beam angle optimization with iCycle may improve plan quality. Computation times for coplanar plans were around 1-2 h and for noncoplanar plans 4-7 h, depending on the number of beams and the complexity of the site. Conclusions: Integrated beam angle and profile optimization with iCycle may result in significant improvements in treatment plan quality. Due to automation, the plan generation workload is minimal. Clinical application has started.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal well placement and brine extraction for pressure management during CO 2 sequestration

Large-scale pressure increases resulting from carbon dioxide (CO 2 ) injection in the subsurface can potentially impact caprock integrity, induce reactivation of critically stressed faults, and drive CO 2 or brine through conductive features into shallow groundwater. Pressure management involving the extraction of native fluids from storage formations can be used to reduce such pressure increases. However, dealing with large volumes of extracted brine can be technically challenging and expensive. Selection of optimal well locations and pumping rates are critical for maximizing CO 2 storage and minimizing brine extraction during geologic CO 2 sequestration (GCS). Robust and efficient computerized algorithms combining reservoir models and optimization methods are needed to make proper decisions on well placement and pumping rates. This work presents a constrained differential evolution (CDE) algorithm for solving global optimization problems involving pressure management of GCS projects. Application of the CDE optimization methodology was demonstrated for a hypothetical CO 2 storage scenario in a deep sandstone reservoir in the Southern San Joaquin Basin in California, USA. Industrial-scale storage of CO 2 would generate significant pressure buildup in this formation, which in turn would raise concerns about induced seismicity due to presence of multiple faults surrounding the injection site. Through the CDE optimization algorithm coupled to a vertically-averaged reservoir simulator, we successfully estimated optimal solutions for brine extraction wells in the reservoir that would limit the local pressure along the faults to a prescribed threshold. Multiple realizations of the reservoir permeability field were created to understand the impact of reservoir heterogeneity on optimization results. Our results indicate that the reservoir slope and heterogeneity have significant impact on optimum extraction rates. Reservoir heterogeneity is also a significant factor for extraction well locations, suggesting that in practice decisions about extraction well placement through optimization should be made at later project stages when data from a few years of CO 2 injection have allowed iterative updating and refining of the reservoir forward models. Although the study focused on optimization of brine extraction, the CDE optimization methodology presented in this paper has also potential to solve other complex optimization problems related to GCS, such as increasing storage efficiency by enhancing injectivity and capillary and dissolution trapping.

58 GEOSCIENCES↗

Spectral optimization for micro-CT

Purpose: To optimize micro-CT protocols with respect to x-ray spectra and thereby reduce radiation dose at unimpaired image quality. Methods: Simulations were performed to assess image contrast, noise, and radiation dose for different imaging tasks. The figure of merit used to determine the optimal spectrum was the dose-weighted contrast-to-noise ratio (CNRD). Both optimal photon energy and tube voltage were considered. Three different types of filtration were investigated for polychromatic x-ray spectra: 0.5 mm Al, 3.0 mm Al, and 0.2 mm Cu. Phantoms consisted of water cylinders of 20, 32, and 50 mm in diameter with a central insert of 9 mm which was filled with different contrast materials: an iodine-based contrast medium (CM) to mimic contrast-enhanced (CE) imaging, hydroxyapatite to mimic bone structures, and water with reduced density to mimic soft tissue contrast. Validation measurements were conducted on a commercially available micro-CT scanner using phantoms consisting of water-equivalent plastics. Measurements on a mouse cadaver were performed to assess potential artifacts like beam hardening and to further validate simulation results. Results: The optimal photon energy for CE imaging was found at 34 keV. For bone imaging, optimal energies were 17, 20, and 23 keV for the 20, 32, and 50 mm phantom, respectively. For density differences, optimal energies varied between 18 and 50 keV for the 20 and 50 mm phantom, respectively. For the 32 mm phantom and density differences, CNRD was found to be constant within 2.5% for the energy range of 21-60 keV. For polychromatic spectra and CMs, optimal settings were 50 kV with 0.2 mm Cu filtration, allowing for a dose reduction of 58% compared to the optimal setting for 0.5 mm Al filtration. For bone imaging, optimal tube voltages were below 35 kV. For soft tissue imaging, optimal tube settings strongly depended on phantom size. For 20 mm, low voltages were preferred. For 32 mm, CNRD was found to be almost independent of tube voltage. For 50 mm, voltages larger than 50 kV were preferred. For all three phantom sizes stronger filtration led to notable dose reduction for soft tissue imaging. Validation measurements were found to match simulations well, with deviations being less than 10%. Mouse measurements confirmed simulation results. Conclusions: Optimal photon energies and tube settings strongly depend on both phantom size and imaging task at hand. For in vivo CE imaging and density differences, strong filtration and voltages of 50-65 kV showed good overall results. For soft tissue imaging of animals the size of a rat or larger, voltages higher than 65 kV allow to greatly reduce scan times while maintaining dose efficiency. For imaging of bone structures, usage of only minimum filtration and low tube voltages of 40 kV and below allow exploiting the high contrast of bone at very low energies. Therefore, a combination of two filtrations could prove beneficial for micro-CT: a soft filtration allowing for bone imaging at low voltages, and a variable stronger filtration (e.g., 0.2 mm Cu) for soft tissue and contrast-enhanced imaging.

60 APPLIED LIFE SCIENCES↗

Optimization of convergent collimators for pixelated SPECT systems

Purpose: The optimization of the collimator design is essential to obtain the best possible sensitivity in single photon emission computed tomography imaging. The aim of this work is to present a methodology for maximizing the sensitivity of convergent collimators, specifically designed to match the pitch of pixelated detectors, for a fixed spatial resolution value and to present some initial results using this approach. Methods: Given the matched constraint, the optimal collimator design cannot be simply found by allowing the highest level of septal penetration and spatial resolution consistent with the imposed restrictions, as it is done for the optimization of conventional collimators. Therefore, an algorithm that interactively calculates the collimator dimensions, with the maximum sensitivity, which respect the imposed restrictions was developed and used to optimize cone and fan beam collimators with tapered square-shaped holes for low (60-300 keV) and high energy radiation (300-511 keV). The optimal collimator dimensions were locally calculated based on the premise that each hole and septa of the convergent collimator should locally resemble an appropriate optimal matched parallel collimator. Results: The optimal collimator dimensions, calculated for subcentimeter resolutions (3 and 7.5 mm), common pixel sizes (1.6, 2.1, and 2.5 mm), and acceptable septal penetration at 140 keV, were approximately constant throughout the collimator, despite their different hole incidence angles. By using these input parameters and a less strict septal penetration value of 5%, the optimal collimator dimensions and the corresponding mass per detector area were calculated for 511 keV. It is shown that a low value of focal distance leads to improvements in the average sensitivity at a fixed source-collimator distance and resolution. The optimal cone beam performance outperformed that of other optimal collimation geometries (fan and parallel beam) in imaging objects close to the collimator surface. Conclusions: These results demonstrate the potential of this kind of optimal convergent collimators for the use in small field of view imaging applications.

43 PARTICLE ACCELERATORS↗

Automatic CT simulation optimization for radiation therapy: A general strategy

Purpose: In radiation therapy, x-ray computed tomography (CT) simulation protocol specifications should be driven by the treatment planning requirements in lieu of duplicating diagnostic CT screening protocols. The purpose of this study was to develop a general strategy that allows for automatically, prospectively, and objectively determining the optimal patient-specific CT simulation protocols based on radiation-therapy goals, namely, maintenance of contouring quality and integrity while minimizing patient CT simulation dose. Methods: The authors proposed a general prediction strategy that provides automatic optimal CT simulation protocol selection as a function of patient size and treatment planning task. The optimal protocol is the one that delivers the minimum dose required to provide a CT simulation scan that yields accurate contours. Accurate treatment plans depend on accurate contours in order to conform the dose to actual tumor and normal organ positions. An image quality index, defined to characterize how simulation scan quality affects contour delineation, was developed and used to benchmark the contouring accuracy and treatment plan quality within the predication strategy. A clinical workflow was developed to select the optimal CT simulation protocols incorporating patient size, target delineation, and radiation dose efficiency. An experimental study using an anthropomorphic pelvis phantom with added-bolus layers was used to demonstrate how the proposed prediction strategy could be implemented and how the optimal CT simulation protocols could be selected for prostate cancer patients based on patient size and treatment planning task. Clinical IMRT prostate treatment plans for seven CT scans with varied image quality indices were separately optimized and compared to verify the trace of target and organ dosimetry coverage. Results: Based on the phantom study, the optimal image quality index for accurate manual prostate contouring was 4.4. The optimal tube potentials for patient sizes of 38, 43, 48, 53, and 58 cm were 120, 140, 140, 140, and 140 kVp, respectively, and the corresponding minimum CTDIvol for achieving the optimal image quality index 4.4 were 9.8, 32.2, 100.9, 241.4, and 274.1 mGy, respectively. For patients with lateral sizes of 43–58 cm, 120-kVp scan protocols yielded up to 165% greater radiation dose relative to 140-kVp protocols, and 140-kVp protocols always yielded a greater image quality index compared to the same dose-level 120-kVp protocols. The trace of target and organ dosimetry coverage and the γ passing rates of seven IMRT dose distribution pairs indicated the feasibility of the proposed image quality index for the predication strategy. Conclusions: A general strategy to predict the optimal CT simulation protocols in a flexible and quantitative way was developed that takes into account patient size, treatment planning task, and radiation dose. The experimental study indicated that the optimal CT simulation protocol and the corresponding radiation dose varied significantly for different patient sizes, contouring accuracy, and radiation treatment planning tasks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-C-17A-12: Towards a Passively Optimized Phase-Space Monte Carlo (POPMC) Treatment Planning Method: A Proof of Principle

Purpose: The advent of on-line/off-line adaptive, and biologically-conformal radiation therapy has led to a need for treatment planning solutions that utilize voxel-specific penalties, requiring optimization over a large solution space that is performed quickly, and the dose in each voxel calculated accurately. This work proposes a “passive” optimization framework, which is executed concurrently during Monte Carlo dose calculation, evaluating the cost/benefit of each history during transport, and creates a passively optimized fluence map. Methods: The Monte Carlo code Geant4 v9.6 was used for this study. The standard voxel geometry implementation was modified to support the passive optimization framework, with voxel-specific optimization parameters. Dose-benefit functions, which will increase a particle history’s weight upon dose deposition, were defined in a central collection of voxels to effectively create target structures. Histories that deposit energy to voxels are reweighted based on a voxel’s dose multiplied by its cost/benefit value. Upon full termination of each history, the dose contributions of that history are reweighted to reflect a contribution proportional to the history’s final weight. A parallel-planar 1.25 MeV photon fluence is transported through the geometry, and re-weighted at each dose deposition step. The resulting weight is tallied with the incident spatial and directional coordinates in a phase-space distribution. Results: A uniform incident fluence was reweighted during MC dose calculations to create an optimized fluence map which would generate dose profiles in target volumes that exhibit the same dose characteristics as the prescribed optimization parameters. An optimized dose profile, calculated concurrently with the phase-space, reflects the resulting dose distribution. Conclusion: This study demonstrated the feasibility of passively optimizing an incident fluence map during Monte Carlo dose calculations. The flexibility of the voxel-specific optimization framework allows a variety and combination of optimization parameters to be calculated for each voxel at every transportation step. This work is partially supported by Varian. This work is partially supported by the NIH.

07 ISOTOPE AND RADIATION SOURCES↗

TH-C-BRD-10: An Evaluation of Three Robust Optimization Approaches in IMPT Treatment Planning

Purpose: Various robust optimization approaches have been proposed to ensure the robustness of intensity modulated proton therapy (IMPT) in the face of uncertainty. In this study, we aim to investigate the performance of three classes of robust optimization approaches regarding plan optimality and robustness. Methods: Three robust optimization models were implemented in our in-house IMPT treatment planning system: 1) L2 optimization based on worst-case dose; 2) L2 optimization based on minmax objective; and 3) L1 optimization with constraints on all uncertain doses. The first model was solved by a L-BFGS algorithm; the second was solved by a gradient projection algorithm; and the third was solved by an interior point method. One nominal scenario and eight maximum uncertainty scenarios (proton range over and under 3.5%, and setup error of 5 mm for x, y, z directions) were considered in optimization. Dosimetric measurements of optimized plans from the three approaches were compared for four prostate cancer patients retrospectively selected at our institution. Results: For the nominal scenario, all three optimization approaches yielded the same coverage to the clinical treatment volume (CTV) and the L2 worst-case approach demonstrated better rectum and bladder sparing than others. For the uncertainty scenarios, the L1 approach resulted in the most robust CTV coverage against uncertainties, while the plans from L2 worst-case were less robust than others. In addition, we observed that the number of scanning spots with positive MUs from the L2 approaches was approximately twice as many as that from the L1 approach. This indicates that L1 optimization may lead to more efficient IMPT delivery. Conclusion: Our study indicated that the L1 approach best conserved the target coverage in the face of uncertainty but its resulting OAR sparing was slightly inferior to other two approaches.

60 APPLIED LIFE SCIENCES↗