Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical detectability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Time-Resolved X-ray Emission Spectroscopy and Synthetic High-Spin Model Complexes Resolve Ambiguities in Excited-State Assignments of Transition-Metal Chromophores: A Case Study of Fe-Amido Complexes

To fully harness the potential of abundant metal coordination complex photosensitizers, a detailed understanding of the molecular properties that dictate and control the electronic excited-state population dynamics initiated by light absorption is critical. In the absence of detectable luminescence, optical transient absorption (TA) spectroscopy is the most widely employed method for interpreting electron redistribution in such excited states, particularly for those with a charge-transfer character. The assignment of excited-state TA spectral features often relies on spectroelectrochemical measurements, where the transient absorption spectrum generated by a metal-to-ligand charge-transfer (MLCT) electronic excited state, for instance, can be approximated using steady-state spectra generated by electrochemical ligand reduction and metal oxidation and accounting for the loss of absorptions by the electronic ground state. However, the reliability of this approach can be clouded when multiple electronic configurations have similar optical signatures. Using a case study of Fe(II) complexes supported by benzannulated diarylamido ligands, we highlight an example of such an ambiguity and show how time-resolved X-ray emission spectroscopy (XES) measurements can reliably assign excited states from the perspective of the metal, particularly in conjunction with accurate synthetic models of ligand-field electronic excited states, leading to a reinterpretation of the long-lived excited state as a ligand-field metal-centered quintet state. Furthermore, a detailed analysis of the XES data on the long-lived excited state is presented, along with a discussion of the ultrafast dynamics following the photoexcitation of low-spin Fe(II)-N amido complexes using a high-spin ground-state analogue as a spectral model for the 5 T 2 excited state.

14 SOLAR ENERGY↗

Excitonic density wave and spin-valley superfluid in bilayer transition metal dichalcogenide

Artificial moiré superlattices in 2 d van der Waals heterostructures are a new venue for realizing and controlling correlated electronic phenomena. Recently, twisted bilayer WSe 2 emerged as a new robust moiré system hosting a correlated insulator at moiré half-filling over a range of twist angle. In this work, we present a theory of this insulating state as an excitonic density wave due to intervalley electron–hole pairing. We show that exciton condensation is strongly enhanced by a van Hove singularity near the Fermi level. Our theory explains the remarkable sensitivity of the insulating gap to the vertical electric field. In contrast, the gap is weakly reduced by a perpendicular magnetic field, with quadratic dependence at low field. The different responses to electric and magnetic field can be understood in terms of pair-breaking versus non-pair-breaking effects in a BCS analog of the system. We further predict superfluid spin transport in this electrical insulator, which can be detected by optical spin injection and spatial-temporal imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Triplet-pair spin signatures from macroscopically aligned heteroacenes in an oriented single crystal

The photo-driven process of singlet fission generates coupled triplet pairs (TT) with fundamentally intriguing and potentially useful properties. The quintet 5 TT 0 sublevel is particularly interesting for quantum information because it is highly entangled, is addressable with microwave pulses, and could be detected using optical techniques. Previous theoretical work on a model Hamiltonian and nonadiabatic transition theory, called the JDE model, has determined that this sublevel can be selectively populated if certain conditions are met. Among the most challenging, the molecules within the dimer undergoing singlet fission must have their principal magnetic axes parallel to one another and to an applied Zeeman field. Here, we present time-resolved electron paramagnetic resonance (TR-EPR) spectroscopy of a single crystal sample of a tetracenethiophene compound featuring arrays of dimers aligned in this manner, which were mounted so that the orientation of the field relative to the molecular axes could be controlled. The observed spin sublevel populations in the paired TT and unpaired (T+T) triplets are consistent with predictions from the JDE model, including preferential 5 TT 0 formation at z ‖ B 0 , with one caveat—two 5 TT spin sublevels have little to no population. This may be due to crossings between the 5 TT and 3 TT manifolds in the field range investigated by TR-EPR, consistent with the intertriplet exchange energy determined by monitoring photoluminescence at varying magnetic fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The properties of the nitrogen-vacancy center in milled chemical vapor deposition nanodiamonds

Fluorescent nanodiamonds (FNDs) containing negatively charged nitrogen-vacancy (NV − ) centers are vital for many emerging quantum sensing applications from magnetometry to intracellular sensing in biology. However, developing a scalable fabrication method for FNDs hosting color centers with consistent bulk-like photoluminescence (PL) and spin coherence properties remains a highly desired but unrealized goal. Here, we investigate optimized ball milling of single-crystal diamonds produced via chemical vapor deposition (CVD) and containing 2 ppm of substitutional nitrogen and 0.3 ppm of NV − to achieve this goal. The NV charge state, PL lifetime, and spin properties of bulk CVD diamond samples are directly compared to milled CVD FNDs and commercial high-pressure high-temperature (HPHT) FNDs. We find that on average, the relative contribution of the NV − charge state to the total NV PL is lower and the NV PL lifetime is longer in CVD FNDs compared to HPHT FNDs, both likely due to the lower N s 0 concentration in CVD FNDs. The CVD bulk and CVD FNDs on average show similar average T 1 spin relaxation times of 3.2 ± 0.7 ms and 4.7 ± 1.6 ms, respectively, compared to 0.17 ± 0.01 ms for commercial HPHT FNDs. Our results demonstrate that ball milling of CVD diamonds enables the large-scale fabrication of NV ensembles in FNDs with bulk-like T 1 spin relaxation properties.

chemical vapor deposition↗

High-efficiency, high-fidelity charge initialization of shallow nitrogen-vacancy centers in diamond

Nitrogen-vacancy (N-𝑉) centers in diamond exhibit long spin-coherence times, optical initialization, and optical-spin readout under ambient conditions, making them excellent quantum sensors. However, the conventional scheme for charge-state initialization based on off-resonant green excitation results in significant state-preparation errors, typically around 30%. One method for improving charge-state initialization fidelity is to use multicolor excitation, which has been demonstrated to achieve a near-unity preparation fidelity for bulk N-𝑉 centers by using a few milliseconds of near-infrared (NIR) (5-mW) and green (10-μ⁢W) excitation. The translation of such schemes to N-𝑉 centers near the diamond surface with higher-efficiency optical pumping would enable new applications in nanoscale sensing. Here, we demonstrate a protocol for efficient charge initialization of shallow N-𝑉 centers between 5 nm and 15 nm from the diamond surface. By carefully studying the charge dynamics of shallow N-𝑉 centers, we identify a region of parameter space that allows for near-unity (95%) charge initialization within 300 μ⁢s of NIR (905-nm, 1-mW) and green (520-nm, 10-μ⁢W) excitation. The time to 90% charge initialization can be as fast as 10 μ⁢s for 4 mW of NIR and 39 μ⁢W of green illumination. This fast, efficient charge initialization protocol will especially benefit nanoscale sensing applications in which state-preparation errors currently prohibit scaling, such as measuring higher-order multipoint correlators.

infrared techniques↗

Thin-film lithium niobate on diamond as a platform for efficient spin-phonon coupling

Negatively charged silicon vacancy (SiV − ) centers in diamond are leading candidates for solid-state quantum memory that can be controlled using electromagnetic or acoustic waves. The latter are particularly promising due to the strong strain response of SiV − , enabling large spin-phonon interaction strengths. Indeed, coherent spin control via surface acoustic waves (SAWs) has been demonstrated and is essential for developing on-chip phononic quantum networks. However, the absence of piezoelectricity in diamond requires an interface with a piezoelectric material for efficient transduction and delivery of acoustic waves to spins in diamonds. Here, we demonstrate a heterogeneously integrated phononic platform that combines thin-film lithium niobate with diamond to enable acoustic control of single SiV − spins. Additionally, leveraging large SAW-induced strain at the location of SiV − , we achieve coherent acoustic control of an electron spin with more than twofold improvement in Rabi frequency compared to state-of-the-art devices based on aluminum nitride on diamond. Furthermore, this work represents a crucial step towards realizing phonon-based quantum information processing systems.

Optically detected magnetic resonance↗

Fast Relaxation on Qutrit Transitions of Nitrogen-Vacancy Centers in Nanodiamonds

Thanks to their versatility, nitrogen-vacancy (N-𝑉) centers in nanodiamonds have been widely adopted as nanoscale sensors. However, their sensitivities are limited by their short coherence times relative to N-𝑉⁢s in bulk diamond. A more complete understanding of the origins of decoherence in nanodiamonds is critical to improving their performance. Here we present measurements of fast spin relaxation on qutrit transitions between the energy eigenstates composed of the 𝑚 𝑠 =|±1⟩ states of the N-𝑉 − electronic ground state in approximately 40-nm nanodiamonds under ambient conditions. For frequency splittings between these states of 20 MHz or less the maximum theoretically achievable coherence time of the N-𝑉 spin is approximately 2 orders of magnitude shorter than would be expected if the N-𝑉 spin is treated as a qubit. We attribute this fast relaxation to electric field noise. We observe a strong falloff of the qutrit relaxation rate with the splitting between the states, suggesting that, whenever possible, measurements with N-𝑉⁢s in nanodiamonds should be performed at moderate axial magnetic fields (>60 G). We also observe that the qutrit relaxation rate changes with time. As a result, these findings indicate that surface electric field noise is a major source of decoherence for N-𝑉⁢s in nanodiamonds.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Vector Electrometry in a Wide-Gap-Semiconductor Device Using a Spin-Ensemble Quantum Sensor

Nitrogen-vacancy (N-V) centers in diamond work as a quantum electrometer. Using an ensemble state of N-V centers, we propose vector electrometry and demonstrate measurements in a diamond electronic device. A transverse electric field applied to the N-V axis under a high voltage is measured, while applying a transverse magnetic field. The response of the energy-level shift against the electric field is significantly enhanced compared with that against an axial magnetic field. Repeating the measurement of the transverse electric field for multiple N-V axes, our team obtains the components of the electric field generated in the device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

N - V –Diamond Magnetic Microscopy Using a Double Quantum 4-Ramsey Protocol

We introduce a double quantum (DQ) 4-Ramsey measurement protocol that enables wide-field magnetic imaging using nitrogen-vacancy (N-V) centers in diamond, with enhanced homogeneity of the magnetic sensitivity relative to conventional single quantum (SQ) techniques. The DQ 4-Ramsey protocol employs microwave-phase alternation across four consecutive Ramsey (4-Ramsey) measurements to isolate the desired DQ magnetic signal from any residual SQ signal induced by microwave pulse errors. In a demonstration experiment employing a 1-μm-thick N-V layer in a macroscopic diamond chip, the DQ 4-Ramsey protocol provides a volume-normalized dc magnetic sensitivity of η V = 34nTHz –1/2 μm 3/2 across a 125 μm × 125 μm field of view, with about 5× less spatial variation in sensitivity across the field of view compared to a SQ measurement. Furthermore, the improved robustness and magnetic sensitivity homogeneity of the DQ 4-Ramsey protocol enables imaging of dynamic broadband magnetic sources such as integrated circuits and electrically active cells.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement and Simulation of the Magnetic Fields from a 555 Timer Integrated Circuit Using a Quantum Diamond Microscope and Finite-Element Analysis

Quantum diamond microscope (QDM) magnetic field imaging is an emerging interrogation and diagnostic technique for integrated circuits (ICs). To date, the ICs measured with a QDM have been either too complex for us to predict the expected magnetic fields and benchmark the QDM performance or too simple to be relevant to the IC community. In this paper, we establish a 555 timer IC as a “model system” to optimize QDM measurement implementation, benchmark performance, and assess IC device functionality. To validate the magnetic field images taken with a QDM, we use a spice electronic circuit simulator and finite-element analysis (FEA) to model the magnetic fields from the 555 die for two functional states. Furthermore, we compare the advantages and the results of three IC-diamond measurement methods, confirm that the measured and simulated magnetic images are consistent, identify the magnetic signatures of current paths within the device, and discuss using this model system to advance QDM magnetic imaging as an IC diagnostic tool.

74 ATOMIC AND MOLECULAR PHYSICS↗

Magnetic Imaging with Spin Defects in Hexagonal Boron Nitride

Optically active spin defects hosted in hexagonal boron nitride (ℎ-BN) are promising candidates for the development of a two-dimensional (2D) quantum sensing unit. Here, we demonstrate quantitative magnetic imaging with ℎ-BN flakes doped with negatively charged boron-vacancy ($V^{-}_{B}$) centers through neutron irradiation. As a proof-of-concept, we image the magnetic field produced by Cr⁢Te 2 , a van der Waals ferromagnet with a Curie temperature slightly above 300 K. Compared to other quantum sensors embedded in 3D materials, the advantages of the ℎ-BN-based magnetic sensor described in this work are its ease of use, high flexibility, and, more importantly, its ability to be placed in close proximity to a target sample. Further, such a sensing unit will likely find numerous applications in 2D materials research by offering a simple way to probe the physics of van der Waals heterostructures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbon complexes in highly C-doped GaN

We investigate the properties of heavily C-doped GaN grown by hydride vapor phase epitaxy using both optical experiments and hybrid density functional theory calculations. Previous work has established that carbon acceptors (C N ) give rise to a yellow luminescence band near 2.2 eV along with a blue luminescence band near 2.9 eV. Photoluminescence measurements show the yellow band shifting as a function of carbon concentration, suggesting a change in the behavior of carbon species as carbon content increases. With hybrid density functional theory we calculate the electrical and optical behavior of carbon centers containing multiple carbon impurities, which may arise in heavily doped material. We compare the behavior of these complexes to the isolated centers, and find that the dicarbon donor-acceptor (C Ga –C N ) complex is a candidate to explain the shift in the yellow luminescence peak. Tricarbon complexes have high formation energies and modest binding energies, and also give rise to optical transitions that are inconsistent with the observed spectra. We also identify the split dicarbon interstitial on the gallium site as a low-energy species with a large binding energy that may act to compensate carbon acceptors. Here, local vibrational modes are calculated for carbon impurity centers, and we compare these results to recent experiments. Dicarbon and tricarbon complexes involving C Ga and C N exhibit modes that are only slightly higher than the isolated species, while carbon interstitials and related complexes give rise to vibrational modes much higher than C Ga and C N .

36 MATERIALS SCIENCE↗

chemostat_regression

Automatically detect chemostat optical density dilution cycles and calculate growth rate regression slopes.

Koehler, Samuel I↗

Real-time jitter correction in a photonic analog-to-digital converter

A real-time jitter meter is used to measure and digitally sample the pulse-to-pulse timing error in a laser pulse train. The jitter meter is self-referenced using a single-pulse delay line interferometer and measures timing jitter using optical heterodyne detection between two frequency channels of the pulse train. Jitter sensitivity down to 3×10 -10 fs 2 /Hz at 500 MHz has been demonstrated with a pulse-to-pulse noise floor of 1.6 fs. Furthermore, as a proof of principle, the digital correction of the output of a high-frequency photonic analog-to-digital converter (PADC) is demonstrated with an emulated jitter signal. Up to 23 dB of jitter correction, down to the noise floor of the PADC, is accomplished with radio-frequency modulation up to 40 GHz.

47 OTHER INSTRUMENTATION↗

Enhancing Molecular Isotope Detection with a Chirp Tuned Optical Centrifuge

This paper gives a brief experimental overview on creating a chirp-tunable optical centrifuge with the goal of amplifying the isotope shift of a given molecule. Results for this experiment were recorded with a CO 2 plume as the probed material. Beyond amplification of the isotope shift, this technology could be modified to alter magnetic field characteristics of common molecules as well as simulating high temperature gases found in combustion environments. Our specific design uses double mirror and grating stretcher and will include a unique tuning feature for customization of the beam’s red and blue components' temporal chirp, allowing for quick reactivity to varying task requirements. The design and parameters will be discussed, as well as the methods used to model the optical centrifuge. Although this experiment is ongoing, results have been gathered previously that display the efficacy of the optical centrifuge. For the probed CO 2 sample, Raman Shifts centered around a wavenumber of 60 and 275 were recorded with durations of 1000 and 800 picoseconds, respectively.

47 OTHER INSTRUMENTATION↗