Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Zoom Lens Calibration for Wind Tunnel Measurements

This report summarizes an investigation of zoom lens calibration, with emphasis on the effects of lens-image-plane misalignment. Measurements have been made of the photogrammetric principal point and radial (symmetrical) and decentering (asymmetrical) distortion components as a function of the principal distance (zoom setting) of several zoom lenses. Data were also taken with the axis of symmetry (optical axis) of a zoom lens aligned and misaligned to the same solid-state video camera. An explanation is offered regarding the variation of the principal point as a function of zoom setting based on these measurements. In addition the relationship of the decentering distortion to radial distortion, principal distance, and lens-image-plane misalignment angle is discussed. A technique for determining the proper point of symmetry to be used for distortion computations (as opposed to the principal point) is also suggested. A simple technique for measuring the misalignment angle of zoom lenses when attached to video cameras is presented, along with measurements for seven solid-state cameras. A method to reduce the additional error introduced by zoom lens misalignment is presented. The implications of this study are that special measures to properly align a zoom lens to the sensor image plane are probably not necessary, but that as the accuracy obtainable in digital photogrammetry approaches the 0.01 or less pixel level, additional calibration including the point of symmetry for distortion computation should be considered.

Burner, A. W.↗

Rotationally Vibrating Electric-Field Mill

A proposed instrument for measuring a static electric field would be based partly on a conventional rotating-split-cylinder or rotating-split-sphere electric-field mill. However, the design of the proposed instrument would overcome the difficulty, encountered in conventional rotational field mills, of transferring measurement signals and power via either electrical or fiber-optic rotary couplings that must be aligned and installed in conjunction with rotary bearings. Instead of being made to rotate in one direction at a steady speed as in a conventional rotational field mill, a split-cylinder or split-sphere electrode assembly in the proposed instrument would be set into rotational vibration like that of a metronome. The rotational vibration, synchronized with appropriate rapid electronic switching of electrical connections between electric-current-measuring circuitry and the split-cylinder or split-sphere electrodes, would result in an electrical measurement effect equivalent to that of a conventional rotational field mill. A version of the proposed instrument is described.

Kirkham, Harold↗

Spacecraft Alignment Determination and Control for Dual Spacecraft Precision Formation Flying

Many proposed formation flying missions seek to advance the state of the art in spacecraft science imaging by utilizing precision dual spacecraft formation flying to enable a virtual space telescope. Using precision dual spacecraft alignment, very long focal lengths can be achieved by locating the optics on one spacecraft and the detector on the other. Proposed science missions include astrophysics concepts with spacecraft separations from 1000 km to 25,000 km, such as the Milli-Arc-Second Structure Imager (MASSIM) and the New Worlds Observer, and Heliophysics concepts for solar coronagraphs and X-ray imaging with smaller separations (50m 500m). All of these proposed missions require advances in guidance, navigation, and control (GNC) for precision formation flying. In particular, very precise astrometric alignment control and estimation is required for precise inertial pointing of the virtual space telescope to enable science imaging orders of magnitude better than can be achieved with conventional single spacecraft instruments. This work develops design architectures, algorithms, and performance analysis of proposed GNC systems for precision dual spacecraft astrometric alignment. These systems employ a variety of GNC sensors and actuators, including laser-based alignment and ranging systems, optical imaging sensors (e.g. guide star telescope), inertial measurement units (IMU), as well as micro-thruster and precision stabilized platforms. A comprehensive GNC performance analysis is given for Heliophysics dual spacecraft PFF imaging mission concept.

Formation flying↗

Spacecraft Alignment Determination and Control for Dual Spacecraft Precision Formation Flying

Many proposed formation flying missions seek to advance the state of the art in spacecraft science imaging by utilizing precision dual spacecraft formation flying to enable a virtual space telescope. Using precision dual spacecraft alignment, very long focal lengths can be achieved by locating the optics on one spacecraft and the detector on the other. Proposed science missions include astrophysics concepts with spacecraft separations from 1000 km to 25,000 km, such as the Milli-Arc-Second Structure Imager (MASSIM) and the New Worlds Observer, and Heliophysics concepts for solar coronagraphs and X-ray imaging with smaller separations (50m-500m). All of these proposed missions require advances in guidance, navigation, and control (GNC) for precision formation flying. In particular, very precise astrometric alignment control and estimation is required for precise inertial pointing of the virtual space telescope to enable science imaging orders of magnitude better than can be achieved with conventional single spacecraft instruments. This work develops design architectures, algorithms, and performance analysis of proposed GNC systems for precision dual spacecraft astrometric alignment. These systems employ a variety of GNC sensors and actuators, including laser-based alignment and ranging systems, optical imaging sensors (e.g. guide star telescope), inertial measurement units (IMU), as well as microthruster and precision stabilized platforms. A comprehensive GNC performance analysis is given for Heliophysics dual spacecraft PFF imaging mission concept.

Virtual Telescope↗

Terahertz magneto-nanoscopy of encapsulated monolayer graphene

This study investigates the nanoscale conductivity of encapsulated monolayer graphene at temperatures down to 5 K and magnetic fields of up to 1 T. We use the scattering-type scanning near-field optical microscopy technique to probe magnetic-field-dependent responses from graphene close to charge neutrality in the terahertz spectral region. We observe the near-perfect high-q reflector behavior of graphene but with subtle changes by the presence of magnetic fields. Measurements align with calculations of the magneto-optical conductivity and the near-field spectroscopic contrast that describes the field-tunable cyclotron resonance of Dirac fermions. Our result provides an initial step toward understanding temperature and magnetic field effects on nanoscale terahertz transport in two-dimensional quantum materials.

Kim, Richard H. J. [Ames Laboratory (AMES), Ames, ↗

On the Alignment and Focusing of the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS)

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a NASA sounding rocket instrument that is designed to observe soft X-ray emissions from 24 - 6.0 A (0.5 - 2.0 keV energies) in the solar atmosphere. For the rst time, high-temperature, low-emission plasma will be observed directly with 5 arcsecond spatial resolution and 22 mA spectral resolution. The unique optical design consists of a Wolter - I telescope and a 3-optic grazing- incidence spectrometer. The spectrometer utilizes a nite conjugate mirror pair and a blazed planar, varied line spaced grating, which is directly printed on a silicon substrate using e-beam lithography. The grating design is being nalized and the grating will be fabricated by the Massachusetts Institute of Technology (MIT) and Izentis LLC. Marshall Space Flight Center (MSFC) is producing the nickel replicated telescope and spectrometer mirrors using the same facilities and techniques as those developed for the ART-XC and FOXSI mirrors. The Smithsonian Astrophysical Observatory (SAO) will mount and align the optical sub-assemblies based on previous experience with similar instruments, such as the Hinode X-Ray Telescope (XRT). The telescope and spectrometer assembly will be aligned in visible light through the implementation of a theodolite and reference mirrors, in addition to the centroid detector assembly (CDA) { a device designed to align the AXAF-I nested mirrors. Focusing of the telescope and spectrometer will be achieved using the X-ray source in the Stray Light Facility (SLF) at MSFC. We present results from an alignment sensitivity analysis performed on the on the system and we also discuss the method for aligning and focusing MaGIXS.

solar↗

A simplified di-homodyne transient grating spectroscopy system utilizing polarization

Here, a modification to the di-homodyne transient grating spectroscopy optical arrangement is presented that removes the need to individually align two spatially separated probe laser beams. This work details the novel application of a single probe beam that utilizes birefringent materials to produce two optically homodyned signals with a relative phase shift of π radians. This arrangement effectively simplifies the alignment to one probe beam and removes the relative phase shift ambiguity between each homodyned signal. Several example measurements for tungsten, titanium, molybdenum, and silicon are shown to illustrate the utility of the new optical system.

Simmonds, M. J. [Univ. of California, San Diego, C↗

High level of integration of front-end imaging optics system for electron cyclotron emission imaging diagnostics on the DIII-D tokamak

The optics system of the Electron Cyclotron Emission Imaging (ECEI) diagnostics on the DIII-D tokamak has been developed and installed for high-resolution temperature fluctuations measurement in the previous decade. The System-on-Chip approach upgrade was finished in June 2019 with high integrated receiver array with 20 individual modules. In this paper, we design new optics with high-level integration. In the new optics system, there will be two mirrors from plasma to receiver array, including one replaceable curved mirror out of the vacuum and one fixed curved mirror in the vessel. There are two options with 1:1 and 1:2 magnifications for high poloidal resolution and larger poloidal window modes. Overall, the new optics system has multiple improvements, including lighter weight, smaller size, more flexible installation and alignment. The synthetic ECEI module is used to evaluate the new optics system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Neutron Star Interior Composition Explorer (NICER): Design and Development

During 2014 and 2015, NASA's Neutron star Interior Composition Explorer (NICER) mission proceeded successfully through Phase C, Design and Development. An X-ray (0.2{12 keV) astrophysics payload destined for the International Space Station, NICER is manifested for launch in early 2017 on the Commercial Resupply Services SpaceX-11 flight. Its scientific objectives are to investigate the internal structure, dynamics, and energetics of neutron stars, the densest objects in the universe. During Phase C, flight components including optics, detectors, the optical bench, pointing actuators, electronics, and others were subjected to environmental testing and integrated to form the flight payload. A custom-built facility was used to co-align and integrate the X-ray \concentrator" optics and silicon-drift detectors. Ground calibration provided robust performance measures of the optical (at NASA's Goddard Space Flight Center) and detector (at the Massachusetts Institute of Technology) subsystems, while comprehensive functional tests prior to payload-level environmental testing met all instrument performance requirements. We describe here the implementation of NICER's major subsystems, summarize their performance and calibration, and outline the component-level testing that was successfully applied.

SEXTANT↗

Performance of the Multi-Spectral Solar Telescope Array. III - Optical characteristics of the Ritchey-Chretien and Cassegrain telescopes

The Multi-Spectral Solar Telescope Array (MSSTA), which is a sounding-rocket-borne observatory for investigating the sun in the soft X-ray/EUV and FUV regimes of the electromagnetic spectrum, utilizes single reflection multilayer coated Herschelian telescopes for wavelengths below 100 A, and five doubly reflecting multilayer coated Ritchey-Chretien and two Cassegrain telescopes for selected wavelengths in the EUV region between 100 and 1000 A. The paper discusses the interferometric alignment, testing, focusing, visible light testing, and optical performance characteristics of the Ritchey-Chretien and Cassegrain telescopes of MSSTA. A schematic diagram of the MSSTA Ritchey-Chretien telescope is presented together with diagrams of the system autocollimation testing.

Hoover, Richard B.↗

Shack-Hartmann Phasing of Segmented Telescopes: Systematic Effects from Lenslet Arrays

The segments in the Keck telescopes are routinely phased using a Shack-Hartmann wavefront sensor with sub-apertures that span adjacent segments. However, one potential limitation to the absolute accuracy of this technique is that it relies on a lenslet array (or a single lens plus a prism array) to form the subimages. These optics have the potential to introduce wavefront errors and stray reflections at the subaperture level that will bias the phasing measurement. We present laboratory data to quantify this effect, using measured errors from Keck and two other lenslet arrays. In addition, as part of the design of the Thirty Meter Telescope Alignment and Phasing System we present a preliminary investigation of a lenslet-free approach that relies on Fresnel diffraction to form the subimages at the CCD. Such a technique has several advantages, including the elimination of lenslet aberrations.

segmented mirrors↗

X ray microscope/telescope test and alignment

The tasks performed by the Center for Applied Optics (CAO) in support of the Normal Incidence Multilayer X-Ray Optics Program are detailed. The Multi-Spectral Solar Telescope Array (MSSTA) was launched on a Terrier-boosted Black Brant sounding rocket from White Sands Missile Range on 13 May 1991. High resolution images of the sun in the soft x ray to extreme ultraviolet (EUV) regime were obtained with normal-incidence Cassegrain, Ritchey-Chretien, and Herschelian telescopes mounted in the sounding rocket. MSSTA represents the first use of multilayer optics to study a very broad range of x ray and EUV solar emissions. Energy-selective properties of multilayer-coated optics allow distinct groups of emission lines to be isolated in the solar corona and transition region. Features of the near and far coronal structures including magnetic loops of plasmas, coronal plumes, coronal holes, faint structures, and cool prominences are visible in these images. MSSTA successfully obtained unprecedented information regarding the structure and dynamics of the solar atmosphere in the temperature range of 10(exp 4)-10(exp 7) K. The performance of the MSSTA has demonstrated a unique combination of ultra-high spatial resolution and spectral differentiation by use of multilayer optics.

Walker, Arthur B. C.↗

Self-assembled HfO 2 -Au nanocomposites with ultra-fine vertically aligned Au nanopillars

Oxide-metal-based hybrid materials have gained great research interest in recent years owing to their potential for multifunctionality, property coupling, and tunability. Specifically, oxide-metal hybrid materials in a vertically aligned nanocomposite (VAN) form could produce pronounced anisotropic physical properties, e.g., hyperbolic optical properties. Herein, self-assembled HfO 2 -Au nanocomposites with ultra-fine vertically aligned Au nanopillars (as fine as 3 nm in diameter) embedded in a HfO 2 matrix were fabricated using a one-step self-assembly process. The film crystallinity and pillar uniformity can be obviously improved by adding an ultra-thin TiN-Au buffer layer during the growth. Here, the HfO 2 -Au hybrid VAN films show an obvious plasmonic resonance at 480 nm, which is much lower than the typical plasmonic resonance wavelength of Au nanostructures, and is attributed to the well-aligned ultra-fine Au nanopillars. Coupled with the broad hyperbolic dispersion ranging from 1050 nm to 1800 nm in wavelength, and unique dielectric HfO 2 , this nanoscale hybrid plasmonic metamaterial presents strong potential for the design of future integrated optical and electronic switching devices.

36 MATERIALS SCIENCE↗

Lens alignment system and method

A lens alignment system and method is disclosed. The disclosed system/method integrates one or more lens retaining members/tubes (LRM/LRT) and focal length spacers (FLS) each comprising a metallic material product (MMP) specifically manufactured to have a thermal expansion coefficient (TEC) in a predetermined range via selection of the individual MMP materials and an associated MMP manufacturing process providing for controlled TEC. This controlled LRM/LRT TEC enables a plurality of optical lenses (POL) fixed along a common optical axis (COA) by the LRM/LRT to maintain precise interspatial alignment characteristics that ensure consistent and/or controlled series focal length (SFL) within the POL to generate a thermally neutral optical system (TNOS). Integration of the POL using this LRM/LRT/FLS lens alignment system reduces the overall TNOS implementation cost, reduces the overall TNOS mass, reduces TNOS parts component count, and increases the reliability of the overall optical system.

Monroe, James Alan↗

Optical See-Through Head Mounted Display Direct Linear Transformation Calibration Robustness in the Presence of User Alignment Noise

Augmented Reality (AR) is a technique by which computer generated signals synthesize impressions that are made to coexist with the surrounding real world as perceived by the user. Human smell, taste, touch and hearing can all be augmented, but most commonly AR refers to the human vision being overlaid with information otherwise not readily available to the user. A correct calibration is important on an application level, ensuring that e.g. data labels are presented at correct locations, but also on a system level to enable display techniques such as stereoscopy to function properly [SOURCE]. Thus, vital to AR, calibration methodology is an important research area. While great achievements already have been made, there are some properties in current calibration methods for augmenting vision which do not translate from its traditional use in automated cameras calibration to its use with a human operator. This paper uses a Monte Carlo simulation of a standard direct linear transformation camera calibration to investigate how user introduced head orientation noise affects the parameter estimation during a calibration procedure of an optical see-through head mounted display.

Axholt, Magnus↗

Thermally Resilient, Broadband Optical Absorber from UV to IR Derived from Carbon Nanostructures

Optical absorber coatings have been developed from carbon-based paints, metal blacks, or glassy carbon. However, such materials are not truly black and have poor absorption characteristics at longer wavelengths. The blackness of such coatings is important to increase the accuracy of calibration targets used in radiometric imaging spectrometers since blackbody cavities are prohibitively large in size. Such coatings are also useful potentially for thermal detectors, where a broadband absorber is desired. Au-black has been a commonly used broadband optical absorber, but it is very fragile and can easily be damaged by heat and mechanical vibration. An optically efficient, thermally rugged absorber could also be beneficial for thermal solar cell applications for energy harnessing, particularly in the 350-2,500 nm spectral window. It has been demonstrated that arrays of vertically oriented carbon nanotubes (CNTs), specifically multi-walled-carbon- nanotubes (MWCNTs), are an exceptional optical absorber over a broad range of wavelengths well into the infrared (IR). The reflectance of such arrays is 100x lower compared to conventional black materials, such as Au black in the spectral window of 350-2,500 nm. Total hemispherical measurements revealed a reflectance of approximately equal to 1.7% at lambda approximately equal to 1 micrometer, and at longer wavelengths into the infrared (IR), the specular reflectance was approximately equal to 2.4% at lambda approximately equal to 7 micrometers. The previously synthesized CNTs for optical absorber applications were formed using water-assisted thermal chemical vapor deposition (CVD), which yields CNT lengths in excess of 100's of microns. Vertical alignment, deemed to be a critical feature in enabling the high optical absorption from CNT arrays, occurs primarily via the crowding effect with thermal CVD synthesized CNTs, which is generally not effective in aligning CNTs with lengths less than 10 m. Here it has been shown that the electric field inherent in a plasma yields vertically aligned CNTs at small length scales (less than 10 m), which still exhibit broadband, and high-efficiency optical absorption characteristics from the ultraviolet (UV) to IR. A thin and yet highly absorbing coating is extremely valuable for detector applications for radiometry in order to enhance sensitivity. A plasma-based process also increases the potential of forming the optical absorbers at lower synthesis temperatures in the future, increasing the prospects of integrating the absorbers with flexible substrates for low-cost solar cell applications, for example.

Kaul, Anupama B.↗

Direct Coupling From WGM Resonator Disks to Photodetectors

Output coupling of light from a whispering- gallery-mode (WGM) optical resonator directly to a photodetector has recently been demonstrated. By directly is meant that the coupling is effected without use of intervening optical components. Heretofore, coupling of light into and out of WGM resonators has been a complex affair involving the use of such optical components as diamond or glass prisms, optical fibers, coated collimators, and/or fiber tapers. Alignment of these components is time-consuming and expensive. To effect direct coupling, one simply mounts a photodetector in direct mechanical contact with a spacer that is, in turn, in direct mechanical contact with a WGM resonator disk. The spacer must have a specified thickness (typically of the order of a wavelength) and an index of refraction lower, by an adequate margin, than the indices of refraction of the photodetector and the WGM resonator disk. This mechanically simple approach makes it possible to obtain an optimum compromise between maximizing optical coupling and maximizing the resonance quality factor (Q).

Savchenkov, Antoliy↗

A radio optical reference frame. I - Precise radio source positions determined by Mark III VLBI - Observations from 1979 to 1988 and a tie to the FK5

Observations from 600 Mark III VLBI experiments from 1979 to 1988, resulting in 237,681 acceptable pairs of group delay and phase delay rate observations, have been used to derive positions of 182 extragalactic radio sources with typical formal standard errors less than 1 mas. The sources are distributed fairly evenly above delta = -30 deg, and 70 sources have delta greater than 0 deg. Analysis with different troposphere models, as well as internal and external comparisons, indicates that a coordinate frame defined by this set of radio sources should be reliable at the 1 mas level. The right ascension zero point of this reference frame has been aligned with the FK5 by using the optical positions of 28 extragalactic radio sources whose positions are on the FK5 system. Because of known defects in the knowledge of astronomical constants, daily nutation offsets in longitude and obliquity were determined relative to an arbitrary reference day in the set of experiments.

Ma, C.↗